Rotigs 4.0 Brad NaPier MD. Introduction Brad NaPier MD, Otolaryngologist Developed a dental device...
-
Upload
albert-gibson -
Category
Documents
-
view
217 -
download
1
Transcript of Rotigs 4.0 Brad NaPier MD. Introduction Brad NaPier MD, Otolaryngologist Developed a dental device...
Rotigs 4.0Brad NaPier MD
Introduction
• Brad NaPier MD, Otolaryngologist
• Developed a dental device that facilitates bronchoscopic intubation. Marketed for anesthesiologists. Currently sold by Richards Medical in Chicago.
• Rotigs 4.0 is a modification of this platform to provide web based videolaryngoscopy for ER physicians, ENTs, and anesthesiologists.
Rotigs 4.0
• Rotigs platform plus
• LED/CCD Camera with
• USB or Bluetooth connectivity
• Image emailed to ENT physician or anesthesiologist
Purpose• To provide laryngoscopy without a
flexible or rigid laryngoscope in the ER setting
• Provide Rapid Accurate Triage
• Eliminate unnecessary CAT Scans
• Eliminate unnecessary radiation to the patient
Purpose
• Provide visualization to ENT physician at home and ensure accurate diagnosis and treatment.
• Improve cost effective treatment by eliminating unnecessary xrays and CAT scans.
• Patient comfort. No need to perform a transnasal approach. Eliminate epistaxis in patient who are anti coagulated . There is no gagging.
Indications
• Sore throat, tonsillitis, peritonsillar abscess
• Globus pharyngeus, GERD, foreign bodies, fishbones
• Epiglottitis, angioneurotic edema
• Airway evaluation
Specialty Interest
• Pediatric ENT and general ENT
• Rural ER
• Pulmonologists
• Primary care physicians
• Anesthesia pre op airway evaluation
Improve
• Quality of service
• Quality of care
• Cost effectiveness
Physician Buy In• ER docs will appreciate information
without effort, time, and skill required for endoscopy.
• ER docs will shift responsibility for diagnosis and follow up to ENT specialist.
• ENT will appreciate directing care from home and billing for their evaluation.
Market
• 5,000 ERs in the US
• 5,000 operating rooms in the US
• Double these numbers if you include Europe
Path forward• Modify existing LED/CMOS/ USB micro video
camera
• Consider Bluetooth or Wifi connectivity
• Revise injection molding to accommodate camera
• Find existing companies that would benefit from this product with existing distribution system
Proof of concept image
Mannekin
Laryngeal Image with Rotigs 4.0
Without topical anesthesia
Summary• Rotigs 4.0 will improve
awake airway evaluation in an ER setting without endoscopy
• Improves quality of service, care, and is cost effective
• Will be supported by ER, ENT, and Anesthesia.