Rotary Geared Limit Switches GRLS Rotary Geared Limit … · 2021. 4. 30. · 19 Rotary Geared...

3
19 Rotary Geared Limit Switches GRLS Introduction : Rotary Geared Limit Switch GRLS is used to trip motor supply when the moving loads reach the extreme end positions of working zone. The driving motion is transmitted by worm gear through worm shaft. The rotations and movements are transmitted to switches by adjustable cams. A Rotary Geared Limit Switches are suitable for use on Application : reversing drives such as Hoists, Winches, Rolling Mills and various other mechanisms used in steel plants such as Coke Oven, Feeding Machinery etc. Technical Data : Ratios Useful Rotationsl 2 Contacts Model 40 A 2 No + 2 NC Contacts Model 10 A 48 : 1 40 GRLS / 48 / 2SH GRLS / 48 / 4SH / 2 60 : 1 50 GRLS / 60 / 2SH GRLS / 60 / 4SH / 2 96 : 1 80 GRLS / 96 / 2SH GRLS / 96 / 4SH / 2 Rotary Geared Limit Switches GRLS ANAND SYSTEMS ENGINEERING PVT.LTD. 116, Acharya Industrial Estate, Tejpal Compound, Andheri-Kurla Road, Sakinaka Mumbai-400072 Tel: 022-8516819,28560893 Fax: 022-28521418. Email: , [email protected] [email protected] Website: , www.anandsystemengg.com www.anandsystem.in

Transcript of Rotary Geared Limit Switches GRLS Rotary Geared Limit … · 2021. 4. 30. · 19 Rotary Geared...

Page 1: Rotary Geared Limit Switches GRLS Rotary Geared Limit … · 2021. 4. 30. · 19 Rotary Geared Limit Switches GRLS Introduction : Rotary Geared Limit Switch GRLS is used to trip motor

19

RotaryGearedLimitSwitchesGRLS

Introduction : Rotary Geared Limit Switch GRLS is used to trip motor supply

when the moving loads reach the extreme end positions of working zone.

The driving motion is transmitted by worm gear through worm shaft. The rotations

and movements are transmitted to switches by adjustable cams.

A Rotary Geared Limit Switches are suitable for use on Application : reversing drives such as Hoists, Winches, Rolling Mills and various other

mechanisms used in steel plants such as Coke Oven, Feeding Machinery etc.

Technical Data :

Ratios Useful Rotationsl 2 Contacts Model 40 A 2 No + 2 NC Contacts Model 10 A

48 : 1 40 GRLS / 48 / 2SH GRLS / 48 / 4SH / 2

60 : 1 50 GRLS / 60 / 2SH GRLS / 60 / 4SH / 2

96 : 1 80 GRLS / 96 / 2SH GRLS / 96 / 4SH / 2

Rotary Geared Limit Switches GRLS

ANAND SYSTEMS ENGINEERING PVT.LTD.

116, Acharya Industrial Estate, Tejpal Compound, Andheri-Kurla Road,Sakinaka Mumbai-400072 Tel: 022-8516819,28560893 Fax: 022-28521418.Email: , [email protected] [email protected]: , www.anandsystemengg.com www.anandsystem.in

Page 2: Rotary Geared Limit Switches GRLS Rotary Geared Limit … · 2021. 4. 30. · 19 Rotary Geared Limit Switches GRLS Introduction : Rotary Geared Limit Switch GRLS is used to trip motor

Lever Operated Limit Switches

ANAND SYSTEMS ENGINEERING PVT.LTD.

116, Acharya Industrial Estate, Tejpal Compound, Andheri-Kurla Road,Sakinaka Mumbai-400072 Tel: 022-8516819,28560893 Fax: 022-28521418.Email: , [email protected] [email protected]: www.anandsystemengg.com

105

90

145

80

65

195

75

20

100

35

ELEVATION SIDE VIEW

105 90

100

4 Holes Ø7

Lever Operated Limit Switches40A Model LS

Lever Operated Limit Switches 10A Model SLS

INTRODUCTION :Lever ( and weight operated ) typeLimit Switch operates the controlchange- over contacts of motor ofan moving equipment when a cam moving with loads actuates the lever /( or, the weight rests on a surface )of Limit Switch. This to turns the camon a square shaft and operate theNO / NC change over contact elements.

Lever Operated Limit Switches 10A Model SLS

Lever Operated Limit Switches40A Model LS

Page 3: Rotary Geared Limit Switches GRLS Rotary Geared Limit … · 2021. 4. 30. · 19 Rotary Geared Limit Switches GRLS Introduction : Rotary Geared Limit Switch GRLS is used to trip motor

260

120 125

105

60

50

90

105

30°

30 °

4 Holes Ø7

ELEVATION

Normalposition

Operatedposition

110

65

90

25

SIDE VIEW

80

TECHNICAL DATA : Body material Powder coated, Aluminum DiecastDegree of protection IP-55 IS: 13947 part 1Mounting position floor mountingCable Entries Twin, 3/4” BS conduitNo. of contact 2 / 4Contact Silver-cadmiumWire connection Screwed Terminals Thermal Test Current 10 ARated Voltage 500 VAC

TECHNICAL DATA : Body material Powder coated, Aluminum DiecastDegree of protection IP-55 IS: 13947 part 1Mounting position floor mountingCable Entries Twin, 3/4” BS conduitNo. of contact 2 / 4Contact Silver-cadmiumWire connection Screwed Terminals Thermal Test Current 25 ARated Voltage 500 VAC

10 Mode SCWLS 10 Mode SCWLS Weight Operated Limit Switches

40A Model CWLS

Weight Operated Limit Switches

ANAND SYSTEMS ENGINEERING PVT.LTD.

116, Acharya Industrial Estate, Tejpal Compound, Andheri-Kurla Road,Sakinaka Mumbai-400072 Tel: 022-8516819,28560893 Fax: 022-28521418.Email: , [email protected] [email protected]: www.anandsystemengg.com

Weight Operated Limit Switches

Weight Operated Limit Switches

40A Model CWLS

Weight Operated Limit Switches