Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Rosemount 753R Web Based Monitoring
Indicator
• Complete web based monitoring solution frommeasurement to a secure user interface via
iTraX® located on Rosemount.com
• Automate your manual monitoring
applications such as inventory management
• Scalable and flexible design platform enables
easy and cost effective installation practices
• Standard HART® interface for simple
integration
Product Discontinued February 2010
www.ro
Contents
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Rosemount 753R With iTraX® Configuration Data Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
semount.com
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Minimize Risk. Maximize Business Performance.
Minimize Risk
• Eliminate costly tank outages at customer sites
• Mitigate installation and incompatibility risk with a fully integrated and truly wireless solution
• Standardize operations on a single innovative solution platform
• Depend on the reliability and support from the global automation industry leader
• Best-in-class measurement performance, quality, and reliability
Maximize Business Performance
• Eliminate unneeded truck deliveriesfor partial fill
• Automated monitoring to support just-in-time inventory and deliveries
• Improve production planning to anticipate customer demand
• Increase efficiency and productivity for an improved bottom line
• Cost effectively monitor your inventory with readings and often as every 15 minutes
Remote Inventory Monitoring
• Monitor inventory levels 24 hours a day via the web
• Supports Rosemount HART® measurement instrumentation
• Fully integrated hardware solution available with the Rosemount 3051S
Rosemount 753R with iTraX®
TypicalMonitoring Risks
Data Reliability
Hardware
Integration
Technology
Platforms
Rosemount 753R with iTraX® Benefits
TypicalMonitoring Benefits
Simple
Installation
Improved
Planning
Increased
Productivity
Automated
Monitoring
2
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
ITRAX WEB INTERFACE
Scalable and Flexible
• Global implementation with a single platform
• Any remote measurement monitoring need
• Secure and user-friendly interface via standard internet browser
• Automated iTraX®-to-customer database transfer into user ERP system (optional)
Full Functionality
• Remote device configuration
• Complete data historian
• Advanced measurement monitoring
• Alert notifications via email or pager
• Customer-managed accounts
Secure Interface
Centralized server at Tier 1 facility:
• Redundant network and facility
• State of the art encryption and authentication
• Data backup and recovery capabilities
• iTraX® Server with uninterruptible power supply (UPS) backup
• Secure login
3
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Rosemount 753R Features
• GSM/GPRS
• Broad multi-provider network coverage
• Modular and scalable hardware architecture
• Built-in system diagnostic capabilities
• 3 line LCD display
• Scheduled and event driven transmissions
• Store and forward data logging for up to 400 readings
753R REMOTE MOUNT
753R WITH INTEGRATED PRESSURE TRANSMITTER
Figure 1. 753R Remote Mount with Remote Power Supply
Figure 2. 753R Remote Mount with 6-24 Vdc Line Power
Figure 3. 753R with Integrated Pressure Transmitter and Remote Power Supply
Figure 4. 753R with Integrated Pressure Transmitter and 6-24 Vdc Line Power
4
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Specifications
FUNCTIONAL SPECIFICATIONS
Power Supply
External Power Supply (Power Source Option S0)
Voltage = 6 to 24 Vdc
Power = 1.5 watts max
Remote Power Supply (Power Source Option S1)
Rosemount Remote Power Supply with solar panel and
battery (advanced power management for up to 5 years
battery life)
Temperature Limits
Ambient
-4 to 140 °F (-20 to 60 °C)
Storage
-40 to 185 °F (-40 to 85 °C)
Humidity Limits0-100% relative humidity
VibrationSuitable for 60-2000 Hz 2g as specified in IEC 60770-1
PHYSICAL SPECIFICATIONS
Electrical Connections½ - 14 NPT conduit
PaintPolyurethane
Cover O-ringsBuna-N
Shipping Weights
Table Wireless-1. Transmitter Weights without Options
Transmitter Package Add Weight In lb (kg)
753R Housing and RPS
(see Figure 1 on page 4)
5.8 (2.63)
753R Housing only
(see Figure 2 on page 4)
3.6 (1.63)
753R Housing, RPS, and Integrated
Pressure Transmitter
(see Figure 3 on page 4)
8.9 (4.04)
753R and Integrated Pressure
Transmitter
(see Figure 4 on page 4)
6.7 (3.04)
The Rosemount 753R Web Based Monitoring Indicator relies on third party cellular network
service for communications. The Rosemount 753R Web Based Monitoring Indicator may not
function properly during cellular network service failures.
Use of this device in control loops could result in death or serious injury.
The Rosemount 753R Web Based Monitoring Indicator is designed for monitoring use only.
Do not use for control or feedback applications.
Please consult the Rosemount 753R Web Based Monitoring Indicator Product Manual for
important additional information concerning the proper installation and use of this product.
5
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Product Certifications
NOTE
The Rosemount 753R is intended for monitoring purposes only.
The Rosemount 753R is intended for web based monitoring applications
and is not designed to integrate into process control systems.
Approved Manufacturing LocationsRosemount Inc. — Chanhassen, Minnesota USA
Telecommunication/EMC ComplianceFCC ID: IHDT56DB/IC ID: 109O-DB1 is contained within.
This device has met the applicable requirements of the R&TTE Directive.
This device has met the applicable requirements of the EMC Directive
2004/108/EC
Ordinary Locations Certifications for FMAs standard, the transmitter has been examined and tested to determine
that the design meets basic electrical, mechanical, and fire protection
requirements by FM, a nationally recognized testing laboratory (NRTL) as
accredited by the Federal Occupational Safety and Health Administration
(OSHA).
Hazardous Locations Certifications
USA and Canadian Certifications
Factory Mutual (FM) Approvals
N5 FM Class I, Division 2
USA Certificate Number: 3023264
Canadian Certificate Number: 3027229C
Class I, Division 2, Groups A, B, C, and D;
Temperature Class T4 Ta = 70 °C
Enclosure Type 3R
Note: To maintain a Type 3R enclosure, the solar panel
must be pointed upwards.
WARNING
Substitution of components may impair suitability for Division 2.
Explosion Hazard. Do not disconnect equipment when a flammable or
combustible atmosphere is present.
Explosion Hazard. Do not open enclosure or replace battery when
flammable or combustible atmosphere is present.
AVERTISMENT
La substitution des composants peut alterer la convenance a Division 2.
Risque d’explosion. Ne debranchez pas l’equipment quand une atmosphere
inflammable ou combustible est presente.
Risque d’explosion. N’ouvrez pas la cloture ou ne remplacez pas la batterie
quand l’atmosphere inflammable ou combustible est presente.
6
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Dimensional Drawings
Rosemount 753R with Integrated Coplanar Pressure Transmitter Manifold
NoteDimensions are in inches (millimeters)
7
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Rosemount 753R with Integrated Coplanar Pressure Transmitter Manifold and Remote Power Supply
Rosemount 753R with a Coplanar Mounting Bracket
4.20(170)
8.95(227)
5.72(145)
.85(21.6)
.30(7.625)
3.14(80)
5.01(127)
7.06(179)
4.20(107)
9.86(53.24)
6.93(176)
6.93(176)
POSSIBLE ANTENNA ROTATION SHOWN
NoteDimensions are in inches (millimeters)
6.15(156)
2.81(71)
4.70(120)
7.74(197)
.85(21.6)
.30(7.625)
3.54(90)
90
6.25(158)
POSSIBLE ANTENNA ROTATION SHOWN
6.93(176)6.93(176)
NoteDimensions are in inches (millimeters)
8
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Rosemount 753R - Remote Power Supply
Rosemount 753R Remote Power Supply In-Line Mounting Configuration
2.58(65.53)
12.43(315.72)
4.20(107)
9.86(53.24)
7.06(179)
6.15(156)
2.81(71)
4.72(120)
6.90(175)
.85(21.6)
.30(7.625)
5.01(127)
3.14(80)
3.08(78)
U-BOLT BRACKET
90
6.93(176)
6.93(176)
6.24(158)
NoteDimensions are in inches (millimeters)
6.93(176) 6.93
(176)
6.15(156)
2.81(71)
4.72(120)
6.90(175)
7.06(179)
5.72(145)
5.01(127)
.85(21.6)
.30(7.625)
3.14(80)
3.08(78)
U-BOLT BRACKET
90
6.24(158)
6.90(175)
NoteDimensions are in inches (millimeters)
9
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Ordering Information
ITRAX® TRANSMISSION ORDERING INFORMATIONNote: Required with each Rosemount 753R Web Based Monitoring Indicator
Model Product Description
753R Web Based Monitoring Indicator
Code Communications
G GSM/GPRS Wireless To iTraX®
Code Assembly Configuration
0 Assemble to a Rosemount 3051S Pressure Transmitter
1 Remote Mounted Housing Assembly
2 Assemble to a Rosemount 3051S Pressure Transmitter and a Remote Mounted Sensor(1)(2)
Code Measurement Point Protocol
H0 4-20mA/HART Transmitter Input
Code Housing Style Material Conduit Entry Size
1A PlantWeb Housing Aluminum 1/2-14 NPT
Code Power Source
S0AA No Power Accessories (Local Line Power 6-24 Vdc)
S1AA(3) Solar Panel and Battery (Size: 1.5W)
Code Final Destination of Product (Communications Approval)
01 USA
02 Canada
03 Mexico
04 Spain
05 Brazil
06 Argentina(1)
Code Other Options
Discrete I/O
Y1 Discrete I/O (1 Dry Contact) (Consult factory for availability)
Meters
M5(4) PlantWeb LCD Display
Product Certifications
N5 FM Class I, Division 2 for U.S.A. and Canada
Typical Model Number: 753R G 1 H0 1A S1AA 01 M5
(1) Consult factory for availability(2) Only available with Final Destination Code 01 USA(3) Required for Final Destination Code 04 Spain, 05 Brazil, and 06 Argentina(4) Required on all units
Description Invoice Interval Part Number
4 readings, 1 transmission per day, 1 Alarm allowance per day Monthly 00753-9100-0112
12 readings, 3 transmission per day, 1 Alarm allowance per day Monthly 00753-9100-0312
48 readings, 12 transmission per day, 2 Alarm allowances per day Monthly 00753-9100-1212
96 readings, 24 transmission per day, 2 Alarm allowances per day Monthly 00753-9100-2412
10
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Rosemount 753R With iTraX® Configuration Data SheetBOLD = Required Value � Select only one of the items provided★
= Default � One or more of the listed items can be selected
Sales Order No. ______________________ Unit No. _____________________________ Line No. ____________________________
For Factory Use Only
Configuration Information
Customer: _____________________________________________ New iTraX® Account: � Yes � No
Model No.: _____________________________________________ Master iTraX® Username: _________________________________(Maximum of 25 Alpha-Numeric Characters)
P.O. No.:_______________________________________________ Master iTraX® Password: __________________________________(Maximum of 12 Alpha-Numeric Characters)
Line Item: ______________________________________________ (Password required for new iTraX® account only)
753R / iTraX® Information
Device Tag Name:__________________________________________
(20 characters maximum)
Measurement Variables to Transmit: Sensor 1
� PV
� SV
� TV
� QV
Read/Transmit Interval: Sensor 1
� Read every 15 minutes / transmit every 1 hour (24/day)
� Read every 30 minutes / transmit every 2 hours (12/day)
� Read every 2 hours / transmit every 8 hours (3/day)
� Read every 6 hours / transmit every 24 hours (1/day)
Turn-on Time: _______ seconds (default 15 seconds or 2 seconds for integral Rosemount 3051S)
Button Event Time-out: _______ minutes (default 30 minutes)
Power Mode: � Normal (power-saving sleep mode)★
� Always On(1)
Heart Beat Monitoring � Yes � No★
(1) Local power S0AA option required.
Notification E-mail Configuration
E-mail Addresses for Alerts: Maintenance __________________________
Operations/Dispatch __________________________
General __________________________
11
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Alert Configuration
Alert 1 Alert 6
Alert Mode: � Enable � Disable Alert Mode: � Enable � Disable
Alert Name: _____________________________________ Alert Name: _____________________________________
Variable Assign: � PV � SV � TV � QV Variable Assign: � PV � SV � TV � QV
Direction: � Rising � Falling Direction: � Rising � Falling
Unit of Measure: _____________________________________ Unit of Measure: _____________________________________
Set Point: _____________________________________ Set Point: _____________________________________
Dead Band: _____________________________________ Dead Band: _____________________________________
Alert Subject: _____________________________________ Alert Subject: _____________________________________
Alert Message: _____________________________________ Alert Message: _____________________________________
Alert 2 Alert 7
Alert Mode: � Enable � Disable Alert Mode: � Enable � Disable
Alert Name: _____________________________________ Alert Name: _____________________________________
Variable Assign: � PV � SV � TV � QV Variable Assign: � PV � SV � TV � QV
Direction: � Rising � Falling Direction: � Rising � Falling
Unit of Measure: _____________________________________ Unit of Measure: _____________________________________
Set Point: _____________________________________ Set Point: _____________________________________
Dead Band: _____________________________________ Dead Band: _____________________________________
Alert Subject: _____________________________________ Alert Subject: _____________________________________
Alert Message: _____________________________________ Alert Message: _____________________________________
Alert 3 Alert 8
Alert Mode: � Enable � Disable Alert Mode: � Enable � Disable
Alert Name: _____________________________________ Alert Name: _____________________________________
Variable Assign: � PV � SV � TV � QV Variable Assign: � PV � SV � TV � QV
Direction: � Rising � Falling Direction: � Rising � Falling
Unit of Measure: _____________________________________ Unit of Measure: _____________________________________
Set Point: _____________________________________ Set Point: _____________________________________
Dead Band: _____________________________________ Dead Band: _____________________________________
Alert Subject: _____________________________________ Alert Subject: _____________________________________
Alert Message: _____________________________________ Alert Message: _____________________________________
Alert 4 Alert 9
Alert Mode: � Enable � Disable Alert Mode: � Enable � Disable
Alert Name: _____________________________________ Alert Name: _____________________________________
Variable Assign: � PV � SV � TV � QV Variable Assign: � PV � SV � TV � QV
Direction: � Rising � Falling Direction: � Rising � Falling
Unit of Measure: _____________________________________ Unit of Measure: _____________________________________
Set Point: _____________________________________ Set Point: _____________________________________
Dead Band: _____________________________________ Dead Band: _____________________________________
Alert Subject: _____________________________________ Alert Subject: _____________________________________
Alert Message: _____________________________________ Alert Message: _____________________________________
Alert 5 Alert 10
Alert Mode: � Enable � Disable Alert Mode: � Enable � Disable
Alert Name: _____________________________________ Alert Name: _____________________________________
Variable Assign: � PV � SV � TV � QV Variable Assign: � PV � SV � TV � QV
Direction: � Rising � Falling Direction: � Rising � Falling
Unit of Measure: _____________________________________ Unit of Measure: _____________________________________
Set Point: _____________________________________ Set Point: _____________________________________
Dead Band: _____________________________________ Dead Band: _____________________________________
Alert Subject: _____________________________________ Alert Subject: _____________________________________
Alert Message: _____________________________________ Alert Message: _____________________________________
12
Product Data Sheet00813-0100-4379, Rev BA
March 2008 Rosemount 753R Indicator
Example 1: Rising Alert
Example 2: Falling Alert
Deadband
Measurement Value
Alert Set Point
Alert “OFF” Alert “ON” Alert “OFF”
Uni
ts o
f Mea
sure
men
t
Time
Deadband
Measurement Value
Alert Set Point
Alert “OFF” Alert “ON” Alert “OFF”
Uni
ts o
f Mea
sure
men
t
TimeDiscrete Output Configuration
Mode (choose 1): � Enable(1)
� Disable (default)
Trigger Alert Name: _________________________ (must match an Alert Name from alert configurations on page 12)
Direction: � Low > High
� High > Low
(1) Requires Y1 option
Application Information (If Applicable)
Location (city, state, country): _____________________________________________
Process Material Name: _____________________________________________
Material Phase: � Liquid
� Gas
� Solid
� Steam
Expected Date of Installation: _________
13
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
14
Product Data Sheet00813-0100-4379, Rev BA
March 2008
15
Rosemount 753R Indicator
Emerson Process Management
© 2008 Rosemount Inc. All rights reserved.
¢00813-XXXX-XXXXm¤
The Emerson logo is a trade mark and service mark of Emerson Electric Co.Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.PlantWeb is a registered trademark of one of the Emerson Process Management group of companies.All other marks are the property of their respective owners.
Standard terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
Product Data Sheet00813-0100-4379, Rev BA
March 2008Rosemount 753R Indicator
Emerson Process ManagementHeath PlaceBognor RegisWest Sussex PO22 9SHEnglandT 44 (1243) 863 121F 44 (1243) 867 554
Emerson Process Management Asia Pacific Private Limited1 Pandan CrescentSingapore 128461T (65) 6777 8211F (65) 6777 [email protected]
Rosemount Division8200 Market BoulevardChanhassen, MN 55317 USAT (U.S.) 1-800-999-9307T (International) (952) 906-8888F (952) 949-7001
www.rosemount.com