20
English Español Português Indoor Unit ASBA24LFC ASBA30LFC Outdoor Unit AOBR24LFL AOBR30LFT ROOM AIR CONDITIONER WALL MOUNTED TYPE HEAT & COOL MODEL (REVERSE CYCLE) KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED P/N9315345318-03 OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MANUAL DE INSTRUÇÕES

Transcript of ROOM AIR CONDITIONER WALL MOUNTED TYPE - · PDF fileEnglish Español Português...

Engl

ish

Espa

ñol

Port

uguê

s

Indoor UnitASBA24LFCASBA30LFCOutdoor UnitAOBR24LFLAOBR30LFT

ROOM AIR CONDITIONERWALL MOUNTED TYPEHEAT & COOL MODEL(REVERSE CYCLE)

KEEP THIS OPERATION MANUALFOR FUTURE REFERENCEGUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTASGUARDE ESTE MANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA

FUJITSU GENERAL LIMITEDP/N9315345318-03

OPERATING MANUALMANUAL DE FUNCIONAMIENTO

MANUAL DE INSTRUÇÕES

9315345318-03_OM.indb 19315345318-03_OM.indb 1 2/26/2013 11:12:37 AM2/26/2013 11:12:37 AM

En-1

CONTENTS

● Do not attempt to install this air conditioner by yourself.● This unit contains no user-serviceable parts. Always consult authorized service per-

sonnel for repairs.● When moving, consult authorized service personnel for disconnection and installation

of the unit.● Do not become excessively chilled by staying for lengthy periods in the direct cooling

airfl ow.● Do not insert fi ngers or objects into the outlet port or intake grilles.● Do not start and stop air conditioner operation by disconnecting the power supply

cord and so on.● Take care not to damage the power supply cord.● In the event of a malfunction (burning smell, etc.), immediately stop operation, discon-

nect the power supply plug, and consult authorized service personnel.

● Provide occasional ventilation during use.● Do not direct air fl ow at fi replaces or heating apparatus.● Do not climb on, or place objects on, the air conditioner.● Do not hang objects from the indoor unit.● Do not set fl ower vases or water containers on top of air conditioners.● Do not expose the air conditioner directly to water.● Do not operate the air conditioner with wet hands.● Do not pull power supply cord.● Turn off power source when not using the unit for extended periods.● Check the condition of the installation stand for damage.● Do not place animals or plants in the direct path of the air fl ow.● Do not drink the water drained from the air conditioner.● Do not use in applications involving the storage of foods, plants or animals, precision

equipment, or art works.● Connection valves become hot during Heating; handle with care.● Do not apply any heavy pressure to radiator fi ns.● Operate only with air fi lters installed.● Do not block or cover the intake grille and outlet port.● Ensure that any electronic equipment is at least one metre away from either the indoor

or outdoor units.● Avoid installing the air conditioner near a fi replace or other heating apparatus.● When installing the indoor and outdoor unit, take precautions to prevent access to

infants.● Do not use infl ammable gases near the air conditioner.● This appliance is not intended for use by persons (including children) with reduced

physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

DANGER!

CAUTION!

SAFETY PRECAUTIONS

SAFETY PRECAUTIONS ......................................En-1FEATURES AND FUNCTIONS .............................En-2NAME OF PARTS .................................................En-3PREPARATION .....................................................En-5OPERATION ..........................................................En-6TIMER OPERATION .............................................En-8SLEEP TIMER OPERATION .................................En-9MANUAL AUTO OPERATION ...............................En-9

ADJUSTING THE DIRECTION OF AIR CIRCULATION .............................................En-10SWING OPERATION ..........................................En-11COIL DRY OPERATION ......................................En-11CLEANING AND CARE .......................................En-12TROUBLESHOOTING ........................................En-14OPERATING TIPS ...............................................En-15SPECIFICATIONS ...............................................En-16

9315345318-03_OM.indb 19315345318-03_OM.indb 1 2/26/2013 11:12:54 AM2/26/2013 11:12:54 AM

En-2

FEATURES AND FUNCTIONS

INVERTERAt the start of operation, a large power is used to bring the room quickly to the desired temperature. Afterwards, the unit automatically switches to a low power setting for economic and comfortable operation.

COIL DRY OPERATIONThe Indoor unit can be dried by pressing the COIL DRY button on the Remote Controller so as to avoid going moldy and restrain the breed of bacterium.

AUTO CHANGEOVERThe operation mode (cooling, dry, heating) is switched automati-cally to maintain the set temperature, and the temperature is kept constant at all times.

PROGRAM TIMERThe program timer allows you to integrate OFF timer and ON timer operations in a single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

SLEEP TIMERWhen the SLEEP button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during cooling mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.

WIRELESS REMOTE CONTROLLERThe Wireless Remote Controller allows convenient control of air conditioner operation.

HORIZONTAL AIRFLOW: COOLING/DOWNWARD AIRFLOW: HEATING

For cooling, use horizontal airfl ow so the cool air does not blow directly on the occupants in the room. For heating, use down-ward airfl ow to send powerful, warm air to the fl oor and create a comfortable environment.

OMNI-DIRECTIONAL AIR FLOW(SWING OPERATION)

Three-dimensional control over air direction swing is possible through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction fl aps operate automatically according to the operating mode of the unit, it is possible to set air direction based on the operating mode.

REMOVABLE OPEN PANELThe indoor unit’s Open Panel can be removed for easy cleaning and maintenance.

MILDEW-RESISTANT FILTERThe AIR FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.

SUPER QUIET OPERATIONWhen the FAN CONTROL button is used to select QUIET, the unit begins super-quiet operation; the indoor unit’s airfl ow is reduced to produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTERThe polyphenol catechin air cleaning fi lter uses static electricity to clean the air of fi ne particles and dust such as tobacco smoke and plant pollen that are too small to see.The fi lter contains catechin, which is highly effective against various bacteria by suppressing the growth of the bacteria ad-sorbed by the fi lter.Note that when the air cleaning fi lter is installed, the amount of air produced decreases, causing a slight decrease in the air conditioner’s performance.

NEGATIVE AIR IONS DEODORIZING FILTERIt comprises pottery super micro particles, which can produce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home.

The optional wired remote controller (model No. : UTB-YUD) can be used.When you use remote controller, there are following different points as compared with using wireless remote controller.[The additional functions for wired remote controller]● Weekly timer ● Temperature set back timer[The restricted functions for wired remote controller]● ECONOMY ● MAINTENANCE ● THERMO SENSORAnd you can't use both wired remote controller and wireless remote controller simultaneously.(Only one kind can be selected)

WIRED REMOTE CONTROLLER (OPTION)

9315345318-03_OM.indb 29315345318-03_OM.indb 2 2/26/2013 11:12:54 AM2/26/2013 11:12:54 AM

En-3

N

Za

\ ^QR

K

L

M

J

O

X

S

T

U

V

PW

bc

]

[

d

Y

NAME OF PARTS

OPERATION

TIMER

COIL DRY

強制自動MANUAL

AUTO

A

E

9

1

=

8

3

1

8

3

B C

D

F

G

I

H

5

6

4

7

2

F

G

I

H

Fig. 5

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 7

To facilitate explanation, the accompanying illustration has been drawn to show all possible indicators; in actral operation, however, the display will only show those indicators appropriate to the current operation.

Fig. 6

24L 30L

9315345318-03_OM.indb 39315345318-03_OM.indb 3 2/26/2013 11:12:54 AM2/26/2013 11:12:54 AM

En-4

Fig. 6 Remote Controller

J SLEEP buttonK MASTER CONTROL buttonL SET TEMP. button ( / )M COIL DRY buttonN Signal TransmitterO TIMER MODE buttonP TIMER SET ( / ) buttonQ FAN CONTROL buttonR START/STOP buttonS SET button (Vertical)T SET button (Horizontal) U SWING buttonV RESET button W TEST RUN button

● This button is used when installing the condi-tioner, and should not be used under normal conditions, as it will cause the air conditioner’s thermostat function to operate incorrectly.

● If this button is pressed during normal opera-tion, the unit will switch to test operation mode, and the Indoor Unit’s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to fl ash simultaneously.

● To stop the test operation mode, press the START/STOP button to stop the air condi-tioner.

X CLOCK ADJUST buttonY Remote Controller Display (Fig. 7)Z Transmit Indicator[ Clock Display\ Operating Mode Display] T imer Mode Display` Fan Speed Displaya Temperature SET Displayb COIL DRY Displayc SLEEP Displayd SWING Display

NAME OF PARTS

Fig. 1 Indoor Unit

1 Operating Control Panel (Fig. 2)2 MANUAL AUTO button

● When kept on pressing the MANUAL AUTO button for more than 10 seconds, the forced cooling operation will start.

● The forced cooling operation is used at the time of installation.

Only for authorized service personnel’s use.● When the forced cooling operation starts by

any chance, press the START/STOP button to stop the operation.

3 Indicator (Fig. 3)4 Remote Control Signal Receiver5 OPERATION Indicator Lamp (red)6 TIMER Indicator Lamp (green)

● If the TIMER indicator lamp fl ashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See Page 15 Auto Restart).

7 COIL DRY Indicator Lamp (orange)

8 Intake Grille (Fig. 4)9 Front Panel0 Air FilterA Air Flow Direction LouverB Power DiffuserC Right-Left Louver (behind Air Flow Direction Louver)D Drain HoseE Air Cleaning Filter

Fig. 5 Outdoor Unit

F Intake PortG Outlet PortH Pipe UnitI Drain port (bottom)

9315345318-03_OM.indb 49315345318-03_OM.indb 4 2/26/2013 11:12:55 AM2/26/2013 11:12:55 AM

En-5

Load Batteries (Size AAA R03/LR03 × 2) *

1 Press and slide the battery compartment lid on the reverse side to open it.

Slide in the direction of the arrow while pressing the mark. * Batteries are not included with this product.

2 Insert batteries. Be sure to align the battery polarities ( ) correctly.

3 Close the battery compartment lid.

Set the Current time

1 Press the CLOCK ADJUST button (Fig. 6 X). Use the tip of a ball-point pen or other small object to press the button.

2 Use the TIMER SET ( / ) buttons (Fig. 6 P) to adjust the clock to the current time.

button: Press to advance the time. button: Press to reverse the time.

(Each time the buttons are pressed, the time will be advanced/reversed in one-minute increments; hold the buttons depressed to change the time quickly in ten-minute increments.)

3 Press the CLOCK ADJUST button (Fig. 6 X) again. This completes the time setting and starts the clock.

To Use the Remote Controller

● The Remote Controller must be pointed at signal receiver (Fig. 1 4) to operate cor-rectly.

● Operating Range: About 7 meters.● When a signal is properly received by the air conditioner, a beeping sound will be

heard.● If no beep is heard, press the Remote Controller button again.

Remote Controller Holder

PREPARATION CAUTION!● Take care to prevent infants from acciden-

tally swallowing batteries.● When not using the Remote Controller for

an extended period, remove the batteries to avoid possible leakage and damage to the unit.

● If leaking battery fl uid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and consult your physician.

● Dead batteries should be removed im-mediately and disposed of properly, either in a battery collection receptacle or to the appropriate authority.

● Do not attem pt to recharge dry batteries.

Never mix new and used batteries, or bat-teries of different types.Batteries should last about one year under normal use. If the Remote Controller’s operating range becomes appreciably reduced, replace the batteries and press the RESET button with the tip of a ballpoint pen or other small object.

3 To remove the Remote Con-troller (when use at hand).

1 Mount the Holder. 2 Set the Remote Controller.

Screws

Insert

Press in

Slide up

Pull out

9315345318-03_OM.indb 59315345318-03_OM.indb 5 2/26/2013 11:12:55 AM2/26/2013 11:12:55 AM

En-6

OPERATION

Example: When set to COOL.

Example: When set to 26 °C.

Example: When set to AUTO.

To Select Mode Operation

1 Press the START/STOP button (Fig.6 R). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating.

2 Press the MASTER CONTROL button (Fig.6 K) to select the desired mode.

Each time the button is pressed, the mode will change in the following order.

About three seconds later, the entire display will reappear.

To Set the Thermostat

Press the SET TEMP. button (Fig. 6 L). button: Press to raise the thermostat setting. button: Press to lower the thermostat setting.

● Thermostat setting range: AUTO ....................................18-30 °C Heating ..................................16-30 °C Cooling/Dry ...........................18-30 °C

The thermostat cannot be used to set room temperature during the FAN mode (the tem-perature will not appear on the Remote Controller’s Display).

About three seconds later, the entire display will reappear.

The thermostat setting should be considered a standard value, and may differ some-what from the actual room temperature.

To Set the Fan Speed

Press the FAN CONTROL button (Fig. 6 Q).Each time the button is pressed, the fan speed changes in the following order:

AUTO HIGH MED LOW QUIET

About three seconds later, the entire display will reappear.

When set to AUTO: Heating : Fan operates so as to optimally circulate warmed air. However, the fan will operate at very low speed when the temperature of

the air issued from the indoor unit is low. Cooling : As the room temperature approaches that of the thermostat setting, the fan

speed becomes slower. Fan : The fan runs at the low fan speed.

The fan will operate at a very low setting during Monitor operation and at the start of the Heating mode.

SUPER QUIET Operation

When set to Quiet:SUPER QUIET operation begins. The indoor unit’s airfl ow will be reduced for quieter operation.● SUPER QUIET operation cannot be used during Dry mode. (The same is true when

dry mode is selected during AUTO mode operation.)● During Super Quiet operation, Heating and Cooling performance will be reduced some-

what. If the room does not warm up/ cool down when using SUPER QUIET Operation, please adjust the air conditioner’s Fan Speed.

AUTO COOL DRY

HEAT FAN

9315345318-03_OM.indb 69315345318-03_OM.indb 6 2/26/2013 11:12:55 AM2/26/2013 11:12:55 AM

En-7

To Stop Operation

Press the START/STOP button (Fig. 6 R).The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out.

About AUTO CHANGEOVER Operation

AUTO: ● When AUTO CHANGEOVER operation fi rst selected, the fan will operate at very low speed for about one minute, during which time the unit detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room temperature is more than +2 °C → Cooling or dry operation

If the difference between thermostat setting and actual room temperature is within ±2 °C → Monitor operation

If the difference between thermostat setting and actual room temperature is more than –2 °C → Heating operation

● When the air conditioner has adjusted your room’s temperature to near the

thermostat setting, it will begin monitor operation. In the monitor operation mode, the fan will operate at low speed. If the room temperature subse-quently changes, the air conditioner will once again select the appropriate operation (Heating, Cooling) to adjust the temperature to the value set in the thermostat.

(The monitor operation range is ±2 °C relative to the thermostat setting.) ● If the mode automatically selected by the unit is not what you wish, select

one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating: ● Use to warm your room. ● When Heating mode is selected, the air conditioner will operate at very low

fan speed for about 3 to 5 minutes, after which it will switch to the selected fan setting. This period of time is provided to allow the indoor unit to warm up before begin full operation.

● When the room temperature is very low, frost may form on the outside unit, and its performance may be reduced. In order to remove such frost, the unit will automatically enter the defrost cycle from time to time. During Automatic Defrosting operation, the OPERATION Indicator Lamp (Fig. 3 5) will fl ash, and the heat operation will be interrupted.

● After the start of heating operation, it takes some time before the room gets warmer.

Cooling: ● Use to cool your room.Dry: ● Use for gently cooling while dehumidifying your room. ● You cannot heat the room during Dry mode. ● During Dry mode, the unit will operate at low speed; in order to adjust room

humidity, the indoor unit’s fan may stop from time to time. Also, the fan may operate at very low speed when adjusting room humidity.

● The fan speed cannot be changed manually when Dry mode has been selected.

Fan: ● Use to circulate the air throughout your room.

During Heating mode:Set the thermostat to a temperature setting that is higher than the current room tempera-ture. The Heating mode will not operate if the thermostat is set lower than the actual room temperature.During Cooling/Dry mode:Set the thermostat to a temperature setting that is lower than the current room tempera-ture. The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature (in Cooling mode, the fan alone will operate).During Fan mode:You can not use the unit to heat and cool your room.

OPERATION

9315345318-03_OM.indb 79315345318-03_OM.indb 7 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-8

To Use the ON timer or OFF timer

1 Press the START/STOP button (Fig. 6 R) (if the unit is already operating, proceed to step 2). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2 Press the TIMER MODE button (Fig. 6 O) to select the OFF timer or ON timer operation.

Each time the button is pressed the timer function changes in the following order:

CANCEL OFF ON

PROGRAM(OFF → ON, OFF ← ON)

The indoor unit’s green TIMER Indicator Lamp (Fig. 3 6) will light.

3 Use the TIMER SET buttons (Fig. 6 P) to adjust the desired OFF time or ON time.

Set the time while the time display is fl ashing (the fl ashing will continue for about fi ve seconds).

button: Press to advance the time. button: Press to reverse the time.

About fi ve seconds later, the entire display will reappear.

To Use the Program timer

1 Press the START/STOP button (Fig. 6 R). (if the unit is already operating, proceed to step 2). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2 Set the desired times for OFF timer and ON timer. See the section “To Use the ON timer or OFF timer” to set the desired mode

and times. About three seconds later, the entire display will reappear. The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 6) will light.

3 Press the TIMER MODE button (Fig. 6 O) to select the PROGRAM timer operation (OFF ON or OFF ON will display).

The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur fi rst.● The program timer will begin operation. (If the ON timer has been selected

to operate fi rst, the unit will stop operating at this point.) About fi ve seconds later, the entire display will reappear.

About the Program timer● The program timer allows you to integrate OFF timer and ON timer operations in a

single sequence. The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

● The fi rst timer function to operate will be the one set nearest to the current time. The order of operation is indicated by the arrow in the Remote Controller’s Display (OFF → ON, or OFF ← ON).

● One example of Program timer use might be to have the air conditioner automatically stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morn-ing before you arise.

TIMER OPERATIONBefore using the timer function, be sure that the Remote Controller is set to the correct current time (☞ P. 5).

To Cancel the TimerUse the TIMER button to select “CANCEL”.The air conditioner will return to normal opera-tion.

To Change the Timer SettingsPerform steps 2 and 3.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating ConditionsIf you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

To Cancel the TimerUse the TIMER MODE button to select “CAN-CEL”.The air conditioner will return to normal opera-tion.

To Change the Timer Settings1. Follow the instructions given in the section “To

Use the ON Timer or OFF Timer” to select the timer setting you wish to change.

2. Press the TIMER MODE button to select either OFF ON or OFF ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating ConditionsIf you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

9315345318-03_OM.indb 89315345318-03_OM.indb 8 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-9

SLEEP TIMER OPERATIONUnlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.

To Use the SLEEP Timer

While the air conditioner is operating or stopped, press the SLEEP button (Fig. 6 J).The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) lights and the TIMER Indicator Lamp (green) (Fig. 3 6) light.

To Change the Timer Settings

Press the SLEEP button (Fig. 6 J) once again and set the time using the TIMER SET ( / ) buttons (Fig. 6 P).Set the time while the Timer Mode Display is fl ashing (the fl ashing will continue about fi ve seconds).

button: Press to advance the time. button: Press to reverse the time.

About fi ve seconds later, the entire display will reappear.

To Cancel the Timer:Use the TIMER MODE button to select “CAN-CEL”.The air conditioner will return to normal opera-tion.

To Stop the Air Conditioner During Timer Operation:

Press the START/STOP button.

About the SLEEP Timer

To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifi es the thermostat setting in ac-cordance with the set time setting. When the set time has elapsed, the air conditioner completely stops.

During Cooling/Dry operation:When the SLEEP timer is set, the thermostat setting is automati-cally raised 1 °C every sixty minutes. When the thermostat has been raised a total of 2 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.

SLEEP timer setting

During Heating operation:When the SLEEP timer is set, the thermostat setting is automatically lowered 1 °C every thirty minutes. When the ther-mostat has been lowered a total of 4 °C, the thermostat setting at that time is maintained until the set time has elapsed, at which time the air conditioner automatically turns off.

SLEEP timer setting

2 °C 3 °C 4 °C

30minutes

1 °C

1 hour

1 hour30 minutes

Set time

Set time

1 hour

1 °C 2 °C

MANUAL AUTO OPERATIONUse the MANUAL AUTO operation in the event the Remote Controller is lost or otherwise unavailable.

How To Use the Main Unit Controls

Press the MANUAL AUTO button (Fig. 2 2) on the main unit control panel.To stop operation, press the MANUAL AUTO button (Fig. 2 2) once again. (Controls are located inside the Open Panel)

● When the air conditioner is operated with the controls on the Main Unit, it will oper-ate under the same mode as the AUTO mode selected on the Remote Controller (see page 7).

● The fan speed selected will be “AUTO” and the thermostat setting will be stand-ard.(24°C)

9315345318-03_OM.indb 99315345318-03_OM.indb 9 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-10

ADJUSTING THE DIRECTION OF AIR CIRCULATION● Adjust the up, down, left, and right AIR directions with the AIR DIRECTION buttons on the Remote Controller.● Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airfl ow-direction louvers have stopped mov-

ing.

DANGER!● Never place fi ngers or foreign objects inside

the outlet ports, since the internal fan oper-ates at high speed and could cause personal injury.

● Always use the Remote Controller’s SET button to adjust the vertical airfl ow louvers. Attempting to move them manu-ally could result in improper operation; in this case, stop operation and restart. The louvers should begin to operate properly again.

● During use of the Cooling and Dry modes, do not set the Air Flow Direction Louvers in the Heating range (4 - 6) for long periods of time, since water vapor may condense near the outlet louvers and drops of water may drip from the air conditioner. During the Cooling and Dry modes, if the Air Flow Direction Louvers are left in the heating range for more than 30 minutes, they will automatically return to position 3.

● When used in a room with infants, children, elderly or sick persons, the air direction and room temperature should be considered carefully when making settings.

Vertical Air Direction Adjustment

Press the SET button (Vertical) (Fig. 6 S).Each time the button is pressed, the air direction range will change as follows:

1 2 3 4 5 6

Types of Air fl ow Direction Setting:1,2,3 : During Cooling/Dry modes4,5,6 : During Heating mode

The Remote Controller’s display does not change.

● Use the air direction adjustments within the ranges shown above.● The vertical airfl ow direction is set automatically as shown, in accordance with the type

of operation selected. During Cooling/Dry mode : Horizontal fl ow 1 During Heating mode : Downward fl ow 5

● During AUTO mode operation, for the fi rst minute after beginning operation, airfl ow will be horizontal 1; the air direction cannot be adjusted during this period.

● Direction 1 2

Only the direction of the Air Flow Direction Louver changes; the direction of the Power Diffuser does not change.

1

2

3

4

5

6

Horizontal Air Direction Adjustment

Press the SET button (Horizontal)(Fig. 6 T).● Each time the button is pressed, the air direction range will change as follows:

1 2 3 4 5

12

3 45

The remote controller’s display does not change.

9315345318-03_OM.indb 109315345318-03_OM.indb 10 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-11

To select SWING Operation

Press the SWING button (Fig. 6 U).The SWING Display (Fig. 7 d) will light.Each time the SWING button is pressed, the swing operation will change in the following order.

To stop SWING Operation

Press the SWING button and select STOP.Airfl ow direction will return to the setting before swing was begun.

SWING OPERATION

COIL DRY OPERATIONThe Indoor unit can be dried by pressing the COIL DRY button on the Remote Controller so as to avoid going moldy and restrain the breed of bacterium. The COIL DRY Operation will operate for 20 minutes after pressing the COIL DRY button and it will stop automatically.

To select COIL DRY Operation

Press the COIL DRY button (Fig. 6 M) during operation or when it stops.The COIL DRY Display (Fig. 7 b) will light. Then it will disappear after 20 minutes.

To cancel COIL DRY OperationPress the START/STOP button (Fig. 6 R) during COIL DRY Operation.The COIL DRY Display (Fig. 7 b) will go out . Then the operation stops.

About COIL DRY Operation ● Press the COIL DRY button again during COIL DRY Operation, COIL DRY Operation

can be reset.● The COIL DRY Operation cannot get rid of the existed mould or bacterium, and it has

no sterilization effect either.

Begin air conditioner operation before performing this procedure.

Up/down swing operation Left/right swing operation

Swing operation stops Up/down/left/right swing operation

About Swing Operation● Up/down swing: Swing operation begins using the following

range according to the current airfl ow direction. Airfl ow direction is 1–4 (for cooling, dry).

With the upper airfl ow-direction louver in the horizon-tal position, the lower airfl ow-direction louver moves (swings) to direct airfl ow to a wide area.

Airfl ow direction is 3–6 (for heating).With the airfl ow-direction louvers set for downward or straight down airfl ow, airfl ow is directly mainly at the fl oor.

● Left/right swing: The airfl ow-direction louvers move (swing) in the left/right airfl ow direction.

● Up/down/left/right swing: The airfl ow-direction louvers move (swing) in both the up/down and left/right airfl ow directions.

● The SWING operation may stop temporarily when the air conditioner’s fan is not operating, or when operating at very low speeds.

● If the SET button(Vertical) is pressed during the up/down swing operation, the up/down swing operation will stop and if the SET button(Horizontal) is pressed during the left/right swing operation, the left/right swing operation will stop.

9315345318-03_OM.indb 119315345318-03_OM.indb 11 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-12

Cleaning the Intake Grille

1. Remove the Intake Grille.1 Place your fi ngers at both lower ends of the grille panel,

and lift forward; if the grille seems to catch partway through its movement, continue lifting upward to remove.

2 Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal.

Intake Grille

Intake Grille

1

2 2

1

Mounting shaft

Knob

2. Clean with water. Remove dust with a vacuum cleaner; wipe the unit with warm

water, then dry with a clean, soft cloth.

CLEANING AND CARE● Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord.● Be sure the Intake Grille (Fig. 1 8) is installed securely.● When removing and replacing the air fi lters, be sure not to touch the heat exchanger, as personal injury

may result.

3. Replace the Intake Grille.1 Pull the knobs all the way.2 Hold the grille horizontal and set the left and right mounting

shafts into the bearings at the top of the panel.3 Press the place where the arrow on the diagram indicates

and close the Intake Grille.

1

2

Intake Grille

Mounting shaft

Knob

Intake Grille

BearingMounting shaft

Knob

Cleaning the Air Filter1. Open the Intake Grille, and remove the air fi lter.

Lift up the air fi lter’s handle, disconnect the two lower tabs, and pull out.Air fi lter handle

Hooks (two places)

2. Remove dust with a vacuum cleaner or by washing.

After washing, allow to dry thoroughly in a shaded place.

CAUTION!

● To avoid excessive wear of the part and components or malfunctioning of the air conditioning, the user/consumer shall perform preventive maintenance through an accredited technical assistance, periodically. To know the preventive maintenance periodicity, the consumer shall check with the accredited installer or an accredited technical assistance.

● When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

● It is recommended for the user/consumer to demand a copy of the Work Order every time there is a visit of a technical assistance for verifi cation, maintenance, test or repair of the product.

● When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.

● Do not expose the unit body to liquid insecticides or hairsprays.● When shutting down the unit for one month or more, fi rst allow the fan mode to operate continuously for about one-half day to

allow internal parts to dry thoroughly.

9315345318-03_OM.indb 129315345318-03_OM.indb 12 2/26/2013 11:12:56 AM2/26/2013 11:12:56 AM

En-13

3. Replace the Air Filter and close the Intake Grille.1 Align the sides of the air fi lter with the panel, and push in

fully, making sure the two lower tabs are returned properly to their holes in the panel.

Hooks (two places)

2 Close the Intake Grille.(For purposes of example, the illustration shows the unit without Intake Grille installed.)

● Dust can be cleaned from the air fi lter either with a vacuum cleaner, or by washing the fi lter in a solution of mild detergent and warm water. If you wash the fi lter, be sure to allow it to dry thoroughly in a shady place before reinstalling.

● If dirt is allowed to accumulate on the air fi lter, air fl ow will be reduced, lowering operating effi ciency and increasing noise.

● During periods of normal use, the Air Filters should be cleaned every two weeks.

Air Cleaning Filter Installation

1. Open the Intake Grille and remove the Air fi lters.

Air Filter(Right & Left)

2. Install the Air cleaning fi lter set (set of 2).1 Set the air cleaning filter into the air cleaning filter

frame.

Air cleaning fi lter frame

Air cleaning fi lter

Air cleaning fi lter set

2 Engage the latch at both ends of the fi lter with the two hooks at the rear of the air cleaning fi lter frame.

Take care that the air cleaning fi lter does not project beyond the frame.

3 Engage the four fi xing locations at the top and bottom of the air cleaning fi lter frame with the hooks of the air fi lter.

3. Install the two Air fi lters and close the Intake Grille.

● When air cleaning fi lters are used, the effect will increased by setting the fan speed to “High”.

Replacing dirty Air cleaning fi lters

Replace fi lters with the following components (purchased sepa-rately).● POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA13-1● Negative air ions deodorizing fi lter: UTR-FA13-2

1. Open the Intake Grille and remove the Air fi lters.

2. Replace them by two new Air cleaning fi lters.1 Remove the old air cleaning fi lters in reverse order of their

installation.2 Install in the same way as for installation of the air cleaning fi lter set.

3. Install the two Air fi lters and close the Intake Grille.

Hook (2 places at the rear)

Latch (2 places)

Rear of the fi lter

Fixing location, hook (6 places)

CLEANING AND CARE

Air Filter(Right & Left)

Air Filter(Right & Left)

Air Filter(Right & Left)

9315345318-03_OM.indb 139315345318-03_OM.indb 13 2/26/2013 11:12:57 AM2/26/2013 11:12:57 AM

En-14

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker or disconnect the power supply plug, and consult authorized service personnel.Merely turning off the unit’s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off.

TROUBLESHOOTING

WARNING!

Before requesting service, perform the following checks:

Symptom Problem See Page

NORMAL FUNCTION

Doesn’t operate immedi-ately:

● If the unit is stopped and then immediately started again, the com-pressor will not operate for about 3 minutes, in order to prevent fuse blowouts.

● Whenever the Power Supply Plug is disconnected and then reconnected to a power outlet, the protection circuit will operate for about 3 minutes, preventing unit operation during that period.

Noise is heard: ● During operation and immediately after stopping the unit, the sound of water fl owing in the air conditioner’s piping may be heard. Also, noise may be particularly noticeable for about 2 to 3 minutes after starting operation (sound of coolant fl owing).

● During operation, a slight squeaking sound may be heard. This is the result of minute expansion and contraction of the front cover due to temperature changes.

● During Heating operation, a sizzling sound may be heard occasional. This sound is produced by the Automatic Defrosting operation. 15

Smells: ● Some smell may be emitted from the indoor unit. This smell is the result of room smells (furniture, tobacco, etc.) which have been taken into the air conditioner.

Mist or steam are emitted: ● During Cooling or Dry operation, a thin mist may be seen emitted from the indoor unit. This results from the sudden Cooling of room air by the air emitted from the air conditioner, resulting in condensation and misting.

● During Heating operation, the outdoor unit’s fan may stop, and steam may be seen rising from the unit. This is due to Automatic Defrosting operation.

15

In regard to the Air Cleaning FiltersPOLYPHENOL CATECHIN AIR CLEANING FILTER (one sheet)● The Air Cleaning Filters are disposable fi lters. (They can not

be washed and reused.)● For storage of the Air Cleaning Filters, use the fi lters as soon

as possible after the package has been opened. (The air cleaning effect decreases when the fi lters are left in

the opened package)● Generally, the fi lters should be exchanged about every three

months.Please buy delicated air cleaning fi lters (UTR-FA13-1) (Sold separately) to exchange the used dirty air cleaning fi lters.

[Negative air ions deodorizing fi lter (one sheet) — light blue]● The fi lters should be exchanged about every three years so

as to maintain the deodorizing effect.● Filter frame is not a one-off product.

Please buy delicated deodorizing fi lter (UTR-FA13-2) (Sold separately) when exchanging the fi lters.

Maintenance of Deodorizing FiltersIn order to maintain the deodorizing effect, please clean the fi lter in the follow way once three months.1 Remove the deodorizing fi lter.2 Clean with water and dry in the air.

1) Flush the fi lters with high-pressure hot water until the surface of the fi lters are covered with water. Please fl ush with diluent neutral detergent.

Never wash by reaming or rubbing, otherwise it will damage the deodorizing effect.

2) Rinse with water fl ow.3) Dry in shade.

3 Reinstall the deodorizing fi lter.

CLEANING AND CARE

9315345318-03_OM.indb 149315345318-03_OM.indb 14 2/26/2013 11:12:57 AM2/26/2013 11:12:57 AM

En-15

Microcomputer-controlled Automatic Defrosting● When using the Heating mode under conditions of low outdoor

temperature and high humidity, frost may form on the outdoor unit, resulting in reduced operating performance.

In order to prevent this kind of reduced performance, this unit is equipped with a Microcomputer-controlled Automatic Defrost-ing function. If frost forms, the air conditioner will temporarily stop, and the defrosting circuit will operate briefl y (for about 7-15 minutes).

During Automatic Defrosting operation, the OPERATION Indicator Lamp (red) will fl ash.

Operation and Performance

Heating Performance● This air conditioner operates on the heat-pump principle,

absorbing heat from outdoor air and transferring that heat indoors. As a result, the operating performance is reduced as outdoor air temperature drops. If you feel that insuffi cient heating performance is being produced, we recommend you use this air conditioner in conjunction with another kind of heating appliance.

● Heat-pump air conditioners heat your entire room by recircu-lating air throughout the room, with the result that some time may be required after fi rst starting the air conditioner until the room is heated.

TROUBLESHOOTING

OPERATING TIPS

If the problem persists after performing these checks, or if you notice burning smells, or both the ORERATION Indicator Lamp (Fig. 3 5) and the TIMER Indicator Lamp (Fig. 3 6) fl ashes, or only the TIMER Indicator Lamp (Fig. 3 6) fl ashes, immediately stop operation, disconnect the Power Supply, and consult authorized service personnel.

Symptom Items to check See Page

CHECK ONCEMORE

Doesn’t operate at all: ● Is the Power Supply Plug disconnected its outlet?● Has there been a power failure?● Has a fuse blown out, or a circuit breaker been tripped?

● Is the timer operating? 8 - 9

Poor Cooling performance: ● Is the Air Filter dirty?● Air the air conditioner’s intake grille or outlet port blocked?● Did you adjust the room temperature settings (thermostat) correctly?● Is there a window or door open?● In the case of Cooling operation, is a window allowing bright sunlight

to enter? (Close the curtains.)● In the case of Cooling operation, are there heating apparatus and com-

puters inside the room, or are there too many people in the room?

● Is the unit set for SUPER QUIET operation? 6

The unit operates differently from the Remote Controller’s setting:

● Are the Remote Controller’s batteries dead?● Are the Remote Controller’s batteries loaded properly?

5

Symptom Problem See Page

NORMAL FUNCTION

Airfl ow is weak or stops: ● When Heating operation is started, fan speed is temporarily very low, to allow internal parts to warm up.

● During Heating operation, if the room temperature rises above the thermostat setting, the outdoor unit will stop, and the indoor unit will operate at very low fan speed. If you wish to warm the room further, set the thermostat for a higher setting.

● During Heating operation, the unit will temporarily stop operation (be-tween 7 and 15 minutes) as the Automatic Defrosting mode operates. During Automatic Defrosting operation, the OPERATION Indicator Lamp will fl ash.

15

● The fan may operate at very low speed during Dry operation or when the unit is monitoring the room’s temperature. 6

● During SUPER QUIET operation, the fan will operate at very low speed. 6

● In the monitor AUTO operation, the fan will operate at very low speed. 6

Water is produced from the outdoor unit:

● During Heating operation, water may be produced from the outdoor unit due to Automatic Defrosting operation. 15

9315345318-03_OM.indb 159315345318-03_OM.indb 15 2/26/2013 11:12:57 AM2/26/2013 11:12:57 AM

En-16

OPERATING TIPS

Temperature and Humidity Range

Cooling Mode Dry Mode Heating Mode

Outdoor temperature About -10 to 46 °C About -10 to 46 °C About –15 to 24 °C

Indoor temperature About 18 to 32 °C About 18 to 32 °C About 30 °C or less

● If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

● Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.● If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip

onto the fl oor or other objects underneath. (About 80% or more).● If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the

outdoor unit may stop operation for certain period of time.

SPECIFICATIONSMODEL

INDOOR UNIT ASBA24LFC ASBA30LFCOUTDOOR UNIT AOBR24LFL AOBR30LFT

TYPE HEAT & COOL SPLIT TYPE (REVERSE CYCLE)POWER 220 V ~ 60 HzCOOLING

CAPACITY [kW] 7.03 7.91[BTU/h] 24,000 27,000

POWER INPUT [kW] 2.16 2.44CURRENT (MAX.) [A] 9.9 (13.5) 11.2 (17.0)ENERGY EFFICIENCY RATIO [kW/kW] 3.26 3.24AIRFLOW INDOOR UNIT [m3/h] 1,100 1,100

OUTDOOR UNIT [m3/h] 2,470 3,600HEATINGCAPACITY [kW] 7.91 9.08

[BTU/h] 27,000 31,000POWER INPUT [kW] 2.31 2.77CURRENT (MAX.) [A] 10.6 (18.5) 12.7 (19.0)ENERGY EFFICIENCY RATIO [kW/kW] 3.42 3.28AIRFLOW INDOOR UNIT [m3/h] 1,120 1,150

OUTDOOR UNIT [m3/h] 2,570 3,600MAX. PRESSURE [MPa] 4.12 4.12REFRIGERANT (R410A) [kg] 1.65 2.10DIMENSIONS & WEIGHT (NET)

INDOOR UNITHEIGHT [mm] 320WIDTH [mm] 998DEPTH [mm] 228WEIGHT [kg] 14

OUTDOOR UNITHEIGHT [mm] 578 830WIDTH [mm] 790 900DEPTH [mm] 315 330WEIGHT [kg] 43 61

AUTO Restart

In Event of Power Interruption

● The air conditioner power has been interrupted by a power failure. The air conditioner will then restart automatically in its previous mode when the power is restored.

● Operated by setting before the power failure.

● If a power failure occurs during TIMER operation, the timer will be reset and the unit will begin (or stop) operation at the new time setting. In the event that this kind of timer fault occurs the TIMER Indicator Lamp will fl ash (see Page. 4).

● Use of other electrical appliances (electric shaver, etc.) or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction. In this event, temporarily discon-nect the Power Supply Plug, reconnect it, and then use the Remote Controller to resume operation.

9315345318-03_OM.indb 169315345318-03_OM.indb 16 2/26/2013 11:12:57 AM2/26/2013 11:12:57 AM

9315345318-03_OM.indb 179315345318-03_OM.indb 17 2/26/2013 11:13:03 AM2/26/2013 11:13:03 AM

9315345318-03_OM.indb 189315345318-03_OM.indb 18 2/26/2013 11:13:03 AM2/26/2013 11:13:03 AM

9315345318-03_OM.indb 29315345318-03_OM.indb 2 2/26/2013 11:12:54 AM2/26/2013 11:12:54 AM