Room Air ConditionerSVC MANUAL(Exploded View)MODEL : TS-C122YDA0
CAUTIONBefore Servicing the unit, read the safety precautions in General SVC manual.Only for authorized service personnel.
http://biz.lgservice.com
2 Room Air Conditioner
1. Specification
Note:O : Applied, - : No relation* For circuit breaker rating, please conform to local standards wherever necessary.
Some of functions are slightly different depending upon models.The specification may be subject to change without prior notice for purpose ofimprovement.
TS -C1 2 2 YDA03.52
12,000 - -
Power Input Cooling/Heating 1 150/-Running Current Cooling/Heating 5.4/-Starting Current Cooling/Heating 26/-
3.0510.43
-1/220/60
99.3Indoor,Max 8.83Outdoor,Max 18
1.46Indoor,H/M/L 41Outdoor,Max 51
R22, 650(22.92)20(0.22)
Rotary(Non Tropical)PH180X1C-3FTU2
PSCSUNISO 4GSI
Oil Charge 400 cc -
Cross Flow FanMotor Output 46
PropellerAC Induction
Motor Output 8929
3*1.0 -
Liquid Side 6.35(1/4)Gas Side 12.7(1/2)
Drain Hose O.D , I.D 21.5,16(0.85,0.63)902*322*200
35.5*12.68*7.87770*540*2450
30.31*21.26*9.65Indoor 9(19.8)Outdoor 35(77.1)Cooling(Outdoor) 21 ∼ 43Heating(Outdoor) -
137.5
Tool Code(Chassis) SY + ULIndoor + Outdoor
Max. Piping Length m(ft)Max. Elevation Difference m(ft)
Operation RangeoC(oF)oC(oF)
inch
Net Weight kg(lbs)kg(lbs)
mm(in)
DimensionIndoor(W*H*D) mm
inch
Outdoor(W*H*D)
Power and Transmission Cable No.*㎟+No.*㎟PipingConnections
mm(in)mm(in)
Circuit Breaker* APower Supply Cable No.*㎟
Fan(outdoor)TypeMotor Type
W
Fan(Indoor) TypeW
Compressor
TypeModelMotor TypeOil Type
ccO.L.P Name
Refrigerant & Charge(at 7.5m) g(oz)
Additional Refrigerant Charge g/m(oz/ft)
Moisture Removal l/h
Sound Level dB(A)+1dB(A)+1
Power Factor %
Air Flow Rate㎥/min(cfm)㎥/min(cfm)
COP W/WPower Supply Φ / V / Hz
A
EER W/WBtu/h.W
WA
Heating Capacity(Min∼Rating∼Max)
kWBtu/h
ModelsCooling Capacity(Min∼Rating∼Max)
kWBtu/h
Thermistor○
○
-○
3/4/-Auto
ManualWireless Simple
18 ∼ 30 ---○
7h, On/Off○
○
3○
-○
Low Ambient Operation -----
Note:
Special Function
Network FunctionsDry ContactNetwork Solution(LGAP)PI485
Functions
Hot StartJet Cool
Restart Delay(minute)Deice Control(Defrost)
Sleep OperationSoft Dry Operation
Self DiagnosisTimer
Auto Operation (Micom Control)Auto Changeover (Micom Control)
Remocon TypeSetting TemperatureRange
CoolingHeating
Auto Clean
Airflow Direction Control(up&down)Airflow Direction Control(left&right)
CHAOS Wind(Auto Wind)Steps, Fan/Cool/Heat
Temperature ControlPlasma FilterPrefilter(washable/anti-fungus)
Service Manual 3
2. Piping Diagrams
Indoor Unit Outdoor Unit
HeatExchanger(Evaporator)
HeatExchanger(Condenser)
Capillary Tube
Compressor
Accumulator
Gas Side
3-Way Valve
2-Way Valve
Liquid Side
Cooling
High Pressure S/W
Th1
Th2
LOC. Description PCB Connector
Th1 Thermistor for indoor air temperatureCN-TH1
Th2 Thermistor for evaporating temperature
4 Room Air Conditioner
3. Wiring Diagrams
Indoor Unit
CN-MOTOR
CN-N2
CN-N1
FUSERY-COMP4
CN-U/D CN-DISP2CN-HVBRY-COMP3
3854A23009
BR BL GN /
YL
1(L)2(N) 3
GN /
YL
BR BL
Service Manual 5
CapacitorTerminal Block
Outdoor Unit
YELLOW
REDCAPACITOR
H C F
BLUE
RED
BLUE
BLUE
C
SR
YELLOW
OVERLOAD PROTECT
2(N)
BLUE
/GREEN
BLU E
BROWN
BROWN
1(L)
THE UNIT INDOOR
OUTDOOR DIAGRAM WIRING
TERMINAL BLOCK
EBY36312302
FAN
Exploded View
Exploded View
6 Room Air Conditioner
1. Indoor Unit
346810
146811
263230
249941
264110
131410
359011
342800
147581-1
268711
135311
135316
267110
249951
W3300
135314
152302
35211B135516
W0CZZ
352150
354210
135301
354212
W6640
268711
WOFZZ
435301 147582-1
115531
147582-2
Service Manual 7
Outdoor UnitModels: TS-C122YDA0
435511
437212
559010
W0CZZ
W6640
649950
552203-2
435301
437211
552203-1
447910
554032
550140
148000
546810
430400
567502554160
552117
552111
237202
349600
430410
W6631
P/NO : MFL37322726 DECEMBER, 2008