CARRIAGE SHOP – BEFORE MODERNISATION
Rail Nirman Nilayam
New Office Building for Construction Organisation South Central Railway
Presentation by S.K.Sharma, CAO (C) /SCR
![Page 3: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/3.jpg)
First Green Building with GRIHA Registration in Indian Railways. 3 Star
Green rating by ADArSh A Joint collaboration of TERI
and Ministry of Renewable Energy, Govt
of India.
![Page 4: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/4.jpg)
• Leading the transformation of the built environment.
• Are built as designed and perform as expected.• Have lower operating costs and increased
asset value. • Are healthy and comfortable for their
occupants. • Reduce waste sent to landfill.• Conserve energy and water. • Reduce harmful greenhouse gas emissions. • Demonstrate an owner`s commitment to
environment.
![Page 5: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/5.jpg)
1. Indian Green building council-LEED.-Green Building Standard from the U.S. Green Building
Council.2. Indian Bureau of Energy Efficiency(BEE) - Energy
Conservation Building Code (ECBC). 3.GRIHA-Green Rating for Integrated Habitat
Assessment- National Rating System of India. Conceived by TERI and developed jointly with the Ministry of New and Renewable Energy, Government of India.
It is a green building 'design evaluation system', and is suitable for all kinds of buildings in different climatic zones of the country.
ADaRSH, Association for Development and Research of Sustainable Habitats.
Independent platform for the interaction on scientific and administrative issues related to sustainable habitats in the Indian subcontinent. It was founded jointly by TERI (The Energy and Resources Institute, New Delhi) and MNRE (Ministry of New and Renewable Energy,).
![Page 6: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/6.jpg)
First Green Building with GRIHA Registration in Indian Railways.Building constructed with RCC framed structure of G+4 Floors with total plinth area of 4405.90 Sqm. Aimed to achieve Green Building to
Reduce energy consumption.Reduce water consumption and efficient water management.Efficient use of resources during construction.Reduce construction waste.Reduce destruction in ecology.
n
![Page 7: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/7.jpg)
Brief description of State of Art Technology adopted
Aimed to achieve 4 star rating by GRIHA
Building designed with latest guide lines on Earthquake forces and without any expansion joint
Anti termite treatment carried out for the building
Ready mixed concrete used for entire structureFly ash based bricks used for masonry walls.About 40% glazing is used to achieve maximum day light factor using glass with low solar heat gain coefficient(0.24) and maximum transmission(62%)
![Page 8: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/8.jpg)
Saint gobain glass – Nano series – Green Aura – ET425 series is used.Double glazing is used for first floor area which is
having Air-conditioning to minimize energy consumption.Paints containing low voc, low conductance 20 % and High reflectance 80% were used.False ceiling with recyclable materials –Gyp board and mineral accoustic fibre were use which are certified green products.Sensor based urinals, taps and low flow fixtures were provided to reduce water consumption.RO Units in each floor provided for Drinking water.Sewage treatment plant based on FAB ( Fluidized Aerobic Bioreactor ) technology is installed to treat sewage to tertiary standards and reuse for lawn / plant watering ( BOD < 20 ppm, COD < 100 ppm, TSS < 30 ppm, PH – 7 to 8, oil & grease < 10 ppm )
![Page 9: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/9.jpg)
Rain water harvesting provided for entire run off from roof and circulating area and no discharge from site to outside area For 990 sqm of roof area 14 cum size pit with filter media provided as per Rly. Guidelines- 8 lac litre.For 6873 sqm of circulating area , 2 bore wells of 150mm dia and 20 m depth provided with perforated casing and filter media as per GHMC guidelines-50 lac litre.
![Page 10: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/10.jpg)
Fire fighting system with following equipment is provided in the building;
Fire / Smoke Detectors above & below false ceiling.Yard HydrantsWet Risers Sump and exclusive Over Head Tank Electric Fire Pump and a stand by Diesel pump Public Addressing System with a control room
Service corridors are provided all-round the Building for laying pipes, conduits and cables
![Page 11: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/11.jpg)
Modular workstations with proper race ways for running Data andElectric cables are provided for staff.
File compactors are provided for storage of files for
optimum utilization of floor space available.
Provision of LAN for all staff.
![Page 12: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/12.jpg)
Electronics1.Fully automatic access control with Biometric and Smart Cards.2.CCTV at all floors having one month storage.3.All floors having WI-FI facility.4.All systems are connected to central server through wire and WI-FI.
5.4 MBPS Internet connection through OFC by RAILTEL.
![Page 13: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/13.jpg)
![Page 14: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/14.jpg)
Capacity 37.5 KW As per RDSO Specification No.
RDSO/PE/SPEC/PS/0092-2008 (Rev.0) Amendment-3
To support peak electrical load during day time and cater colony lighting & pumping load during holidays & week days.
Requirement of shadow free area = 125 – 150 Sq. ft. / KWp
DC energy produced by solar arrays (of 230 Watts) in connected to AC by PCU and fed to the AC distribution board (metering & isolation panel including energy meter).
Automatic wakeup in the morning in synchronization with grid voltage and frequency isolation facility in case of grid voltage and / or frequency goes of range and reconnects after a predetermined time when grid is back in the range.
![Page 15: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/15.jpg)
![Page 16: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/16.jpg)
Use of luminous efficient light (LED T-5 & CFL)
to achieve Optimum lighting power density.
Energy Efficient light indoor & outdoor chosen as per ECBC-2007
• 4 x 14 W T-5 lamp, reflector of micro optic design
to restrict the glare.
• 4 x 14 Watt T-5 lamp with digital dimmable / DALI
ballast.
• 1 x 18 Watt down light luminary with CFL.
• 1 x 7 W LED luminary down light.
• 1 x 30 W LED luminaries.
• Energy Efficient 1 x 28 W T-5 street light fittings.
![Page 17: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/17.jpg)
• Energy Efficient 1 x 18 W CFL Cylindrical decorative
bollard Garden lighting
• Skylight – to harness day light in dark patches like Rest
rooms & Corridor.
• Energy efficient ceiling fans – 1400 mm sweep.
• Energy Efficient exhaust fans.
ENERGY SAVING SYSTEM / APPROACH
Use of occupancy & multi sensors for Intelligent lighting system and harnessing day light fully.
• Occupancy Sensors
• Multi Sensors – Compatible to DALI based dimming
of lights system
![Page 18: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/18.jpg)
Use of Energy management system for comprehensive
electrical parameters reporting, comparative and
performance analysis and remotely switching ON / OFF
facility of each equipment.Energy Management System Make : Connectgaia
Potential to save power upto 30% by managing power
consumption efficiently and intelligently
Real time monitoring of all the electrical parameters
for all the equipments to keep the down time close
to ZERO as well as plugging wastage of energy due
to faults.
![Page 19: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/19.jpg)
LIFTS – 2 Nos. – OTIS
• Use of gear less and machine room less lifts with
state of the art VVVF drive control with speed
encoder.
• Type and capacity : Passenger lift, 13 Passenger,
884 Kgs.
• Type of drive and control – AC variable voltage,
variable frequency Drive with speed encoder.
• Machine : Gearless and Machine room less with
permanent Magnet motor located in the shaft at top.
• Ropes: Flat polyurethane – Coated belts of required
strength.
• Load – 14 Kw each.
![Page 20: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/20.jpg)
Use of centralized air conditioning through variable
refrigerant flow technology with the facility of
controlling each indoor unit centrally as well as
individually based on occupancy.
AIR CONDITIONERS – (110 KW)
• Out door units – 6 Nos. capacity – 21 hp each(15 kw)
• Indoor units - 44 Nos.
• Multiple digital / inverter scroll compressor with
electronic control centre / micro processor to
enable zone wise climate control.
Use of stand alone solar street lighting system in
addition to programmable day light sensing controller for outdoor lighting.
![Page 21: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/21.jpg)
Use of centralized air cooling for improved thermal comfort in non air conditioned area.
AIR COOLING – (132 KW)
• Centralised air ventilation : 1,50,000 cfm
• No. of AHUs – 8, CAPACITY : 17 KW – 6 nos.
and 15 kw – 2 nos.
• Operated & monitoring through energy management
system and occupancy sensors.
• Temperature range: 22ºc TO 28ºc – can be set by
occupant.
• Ambient temperature : 52ºc
• capacity variation – 10% to 100% by modulation
technology.
• Refrigerant : eco friendly gas – r 410a
![Page 22: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/22.jpg)
Energy Saving cost calculations1.Total peak Load - 226 Kw2.Solar power - 38 Kw3.Balance consumption - 188 Kw4.40 % energy saving - 75 Kw
Saved Energy cost/year@ Rs 5/unit - Rs 16 Lac
![Page 23: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/23.jpg)
![Page 24: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/24.jpg)
![Page 25: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/25.jpg)
For any Technical QueryPlease contact;
S.K.Sharma, Chief Administrative Officer (Con)-9701372110. Vijaya Sharma, Chief Engineer (Con)- 9701372116. Mahboob Ali, Chief Signal and Telecom Engineer-9701372850.
Hundaikar, Chief Electrical Engineer (Con)-9701372
![Page 26: Rnn 02.07.2012 copy](https://reader033.fdocuments.net/reader033/viewer/2022061223/54c5a32e4a7959302b8b481e/html5/thumbnails/26.jpg)
Go GreenThank You