Product Features:
Digital Multifunction power meter - RISH Master 6100
RISHABH INSTRUMENTS PVT.LTD.F-31, MIDC, Satpur, Nashik-422 007,India.Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- [email protected] International :- [email protected]
Rishabh Instruments 1 / 06 / XIII / 1206
Digital Multifunction power meter measures all important electrical
parameters in 3 phase Network & replaces the multiple analog panel meters.
It measures all electrical parameters like AC current, Voltage, Active, reactive
& apparent power, power factor, frequency ,neutral current & active &
reactive energy & THD. The measurement is performance is in all 4
quadrants. The instruments has optional output as modbus RS 485 for
communication to SCADA & One pulse output for energy measurement.
On site programmable PT/CT ratios
THD measurement of Voltage and Currents
for Power Quality analysis
3 Phase 3 Wire or 4 Wire version available
pNominal in ut Current 5 A or 1A
Electrically isolated Current inputs
and Auxiliary Supply
Size: 96 mm x 96 mm DIN Quadratic
high brightness 3 line 4 digits LED display
(Simultaneous display of 3 Parameters)
Low back depth of less than 80 mm
True RMS measurement
Four quadrant operation
Optional Output:
-MODBUS ( Rs485) RTU Protocol
( 2 Wire)
-One Pulse Output (potential free relay) for energy
measurement
Compliance to International Safety standard:
IEC 61010-1- 2001
EMC Compliance: As per IEC 61326
List of Electrical Parameters :
5. Volts B – N (only for 4 Wire System )
6. Volts R – Y
7. Volts Y – B
8. Volts B – R
9. Current IR
10. Current IY
11. Current IB
12. Neutral Current (only for 4 Wire System )
13. Active Power (kW)
14. Reactive Power (kVAr)
15. Apparent Power (kVA)
16. System Power Factor
17. System Frequency
18. Active energy (kWh )
19. Reactive energy (kVArh )
20. Ampere Demand
21. kW Demand
22. Ampere Demand maximum
23. kW Maximum Demand
24. %THD of system voltage
25. %THD of system current
26. %THD of all the 3 L-N voltages (4 wire system)
27. %THD of all the 3 L-L voltages (3wire system)
28. %THD of all the 3 Line currents
1. System Voltage
2. System Ampere
3. Volts R – N (only for 4 Wire System )
4. Volts Y – N (only for 4 Wire System )
RISHABH INSTRUMENTS PVT.LTD.F-31, MIDC, Satpur, Nashik-422 007,India.Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- [email protected] International :- [email protected]
Rishabh Instruments
Technical Specifications:
1 / 06 / XIII / 1206
Digital Multifunction power meter - RISH Master 6100
Nominal input voltage (AC RMS) Phase –Neutral 57 - 277V L-N Line-Line 100 - 480V L-L Max continuous input voltage 120% of rated value Input Current: Nominal input current 1 or 5A AC RMS System CT primary values Std. values up to 4kA (1 or 5 Amp ) Max continuous input current 120% of rated value Auxiliary Supply: Universal Auxiliary Supply 100 - 250V AC/DC +/- 10% AC Auxiliary supply frequency range 40 to 70 Hz Optional Auxiliary DC supply 12 - 48V DC +/- 10% Input VA Burden: Nominal input voltage burden 0.25 VA approx. per phase Nominal input current burden 0.65 VA approx. per phase AC Supply burden 3.5 VA DC Supply burden 3.5 VA Overload Withstand: Voltage 2x for 1 second, repeated 10 times at 10s Current 20x for 1 second, repeated 5 times at 5 min Operating Measuring Ranges Voltage 5 .. 120% of rated value Voltage for THD measurement 50 .. 120% of rated value Current 5 … 120% of rated value Current for THD measurement 10 …120% of rated value Apparent power (VA) 5 .. 120% of rated value, Max 360 Mega VA Active power (W) 5 .. 120% of rated value, Max 360 Mega W Reactive power (VAr) 5 .. 120% of rated value, Max 360 Mega VAr Frequency 45 …66 Hz Power Factor 0.5 Lag ... 1... 0.8 Lead Total Harmonic Distortion(Up to 15th Harmonic )
0%-40%
Reference conditions for Accuracy: Reference temperature 23°C +/- 2°C Input waveform Sinusoidal (distortion factor 0.005) Input frequency 50 or 60 Hz ±2% Auxiliary supply voltage Rated Value ±1% Auxiliary supply frequency Rated Value ±1% Accuracy: Voltage ±0.5% of range (50... 100% of rated value) Current ±0.5% of range (10... 100% of rated value) Neutral current 3% of range Frequency 0.16% of mid frequency (Rated value ±10%) Active power (W) ±1% of range (Voltage =Rated value ±2%, Current 10 ...100% of rated
value, Active power factor 0.866 lagging 1... 0.866 leading)
Reactive power (VAr) ±2% of range (Voltage =Rated value ±2%,Current = 10 ...100% of rated
value, Reactive power factor 0.866 lagging 1... 0.866 leading)
Apparent power (VA) ±1% of range (Voltage =rated value ±2%,Current=10...100% of rated value) Power factor 1% of Unity (Voltage =Rated value ±2%,Current=40...100% of rated value) Active energy (W.h) 1% (IEC 62053 ) Active P.F. 0.866 lag... 1...0.866 lead Reactive energy (VAr.h) 2% (IEC 62053 ) Reactive P.F 0.866 lag... 1...0.866 lead Total Harmonic Distortion (THD – R)
1% ( Voltage: 60….100% of rated value,Current: 20….100% of rated value)
RISHABH INSTRUMENTS PVT.LTD.F-31, MIDC, Satpur, Nashik-422 007,India.Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- [email protected] International :- [email protected]
Rishabh Instruments 1 / 06 / XIII / 1206
Digital Multifunction power meter - RISH Master 6100
Influence of Variations:
Temperature coefficient (for rated value range of use (0…50°C)
0.08%/°C for voltage and 0.13%/°C for other parameters
Display update rate:
Response time to step input
550 milliseconds approx.
Applicable Standards: EMC IEC 61326 Immunity EN61000-4-3. 10V/m min – Level 3 industrial low level Safety IEC61010-1 , Permanently connected use Protection class: Housing protection: IEC60529 Pollution degree: 2 Installation category: III High Voltage Test 2.2 kV AC, 50Hz for 1 minute between all electrical circuits Environmental Operating temperature -10 to +55°C Storage temperature -20 to +65°C Relative humidity 0... 95% non condensing Warm up time Minimum 3 minute Shock 15g in 3 planes Vibration 10... 55 Hz, 0.15mm amplitude Enclosure IP54 (front face only) Serial Communications Option Protocol Modbus (RS 485) Baud rate 19200, 9600, 4800 or 2400
(programmable) Parity Odd or Even, with 1 stop bit,
or None with 1 or 2 stop bits. Active Energy Pulsed Output Option Default pulse rate 1 per kW.hr Pulse rate divisors 10 (yielding 1 pulse per 10 kW.hr) and 100 (yielding 1 pulse per 100 kW.hr) Pulse duration 60 ms, 100 ms or 200 ms
RISHABH INSTRUMENTS PVT.LTD.F-31, MIDC, Satpur, Nashik-422 007,India.Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- [email protected] International :- [email protected]
Rishabh Instruments 1 / 06 / XIII / 1206
Electrical Connections
3 Phase 4 Wire Unbalanced Load
3 Phase 3 Wire Unbalanced Load
It is recommended that the wires used for connections to the instrument should have lugs soldered at the end. That is, the connections should be made with Lugged wires for secure connections. The Maximum diameter of the lug should be 7.0 mm and maximum thickness 3.5 mm. Permissible cross section of the connection wires: <= 4.0 mm2 single wire or 2 × 2.5 mm2 fine wire.
2 5 8 11 1 3 4 6 7 8
L1
L2
L3
NFor Direct operated meter
2 5 8 11 1 3 4 6 7 8
L1
L2
L3
N
K L
K L
K L
k l
k l
lk
For CT operated meter
2 5 8 1 3 7 9
L1
L2
L3
2 5 8 1 3 7 9
L1
L2
L3K L
K L l
l
k
k
For Direct operated meter For CT operated meter
Dimensions
Digital Multifunction power meter - RISH Master 6100
RISHABH INSTRUMENTS PVT.LTD.F-31, MIDC, Satpur, Nashik-422 007,India.Tel.: +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- [email protected] International :- [email protected]
Rishabh Instruments 1 / 06 / XIII / 1206
Ordering Information
Order Code Example : RISH MASTER 6100 – 4 - 415 – 5 – D– R – E RISH MASTER 6100 , 3 phase 4wire, 415L-L nominal voltage, 5A CT secondary , 12 – 48V DC auxiliary supply, with MODBUS (RS485) , with one pulse output option.
Ordering Code
RISH MASTER 6100
System Type
3 Phase 4 Wire 4
3 Phase 3 Wire 3
Input Voltage
100V L-L (57.7V L-N) 100
110 V L-L (63.5V L-N) 110
115 V L-L (66.4V L-N) 115
120 V L-L (69.3V L-N) 120
139 V L-L (80.2V L-N) 139
208 V L-L (120V L-N) 208
240 V L-L (139V L-N) 240
277 V L-L (160V L-N) 277
380 V L-L (220V L-N) 380
400 V L-L (230V L-N) 400
415 V L-L (240V L-N) 415
480 V L-L (277V L-N) 480
600 V L-L (346V L-N) 600
Input Current
1 Amps 1
5 Amps 5
Auxiliary Voltage
12 – 48 DC D
100 – 250V AC/DC A
Optional :
RS485 Modbus RTU or Johnson controls Metasys N2 R
RS485 Modbus Not used Z
Optional:
One kWhr Pulsed output E
Pulsed output Not used Z
Digital Multifunction power meter - RISH Master 6100