RFS Ferrocom Catalog

16
RFS Ferrocom Isolators/Circulators A broad range of ferrite devices which are unequaled in performance, quality and reliability. Ferrocom Ferrite Division Coaxial Isodapters Drop-in Waveguide

description

RFS Ferrocom Catalog

Transcript of RFS Ferrocom Catalog

Page 1: RFS Ferrocom Catalog

RFS Ferrocom Isolators/Circulators

A broad range of ferrite devices which are unequaled in performance,quality and reliability.

Fer rocom Fer r i te D iv i s ion

Coaxial

Isodapters

Drop-in

Waveguide

Page 2: RFS Ferrocom Catalog

TABLE OF CONTENTS

Isolators/Circulators

Introduction..............................................................1

Coaxial Isolators/Circulators ...................................2-3

Connector Options ...................................................4

Isodapters .................................................................5

“R” Class Drop-ins.................................................6-8

“S” Class Drop-ins ....................................................9

Waveguide .............................................................10

4 Port Coaxial for Public Safety Applications............11

Ordering Information ..............................................12

RFQ Order Guide ....................................................13

All information is believed to be accurate at the time of publication, but Radio Frequency Systems shall not be held responsible for print or typographicerrors. Printed May 2011, Revision B © 2011 Radio Frequency Systems

Page 3: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 1

RFS FER

ROCOM IN

TRODUCTION

RFS Ferrocom currently carries over 2,000existing designs as well as a highly skilledengineering staff that is ready to developisolators/circulators to your specifications.Our units are ideally suited for integrationinto compact systems requiringdependable performance with stripline,waveguide, drop-in and isodapterpackages available.

RFS Ferrocom, an industry leader in themanufacture of isolators and circulators,offers a complete line of ferrite devicescovering the range of 80 MHz to 40GHz. Our extensive line of isolators andcirculators extend from narrow bandmodels to units with greater than octavebandwidths. These units provide thelowest possible insertion loss for aspecified set of operating conditions andrequirements. Optimized isolationcharacteristics are accomplished as aresult of state-of-the-art impedancematching and design techniques.

RFS FERROCOM INTRODUCTION

RFS Ferrocom proudly offersthe marketplace a broad rangeof ferrite devices which areunequaled in performance,quality and reliability.

In keeping with ourcommitment to quality, ourfacility is registered to the ISO-9001/2008 qualitystandard and fully compliantwith MIL-I-45208A.

RFS Ferrocom

currently carries

over 2,000

existing

designs

Page 4: RFS Ferrocom Catalog

2 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

RFS FER

ROCOM COAXIAL ISOLA

TORS/CIRCULA

TORS

Standard coaxial isolators and circulators cover a wide frequency spectrum rangingfrom 80 MHz to 30 GHz. These devices offer good electrical performance and easyintegration. Package size varies depending on the operating frequency. Criticalparameters can be optimized to meet specific requirements for each application.SMA-type connectors are the standard interface. Other connector options areavailable upon request.

• Isolator load rating 10 Watts. Circulator power rated at 2.0:1 mismatch.

• Additional frequencies available.

• Custom configurations available including various connector types andmultiport options.

Product Specifications

COAXIAL ISOLATORS/CIRCULATORS

Model Frequency, Isolation VSWR Insertion Loss Operating Dimensions Power, Power, Weight,Number GHz Typ, dB Min, dB Typ Max Typ, dB Max, dB Temperature, C (A x B x C), in Peak, W Avg, W G

9T17 0.132-0.146 24.0 20.0 1.14 1.25 0.40 0.60 -30 to +70 3.40 x 3.62 x 1.51 2K 350 1500

9T18 0.144-0.160 24.0 20.0 1.14 1.25 0.40 0.60 -30 to +70 3.40 x 3.62 x 1.51 2K 350 1500

9T19 0.158-0.175 24.0 20.0 1.14 1.25 0.40 0.60 -30 to +70 3.40 x 3.62 x 1.51 2K 350 1500

9T20 0.173-0.200 24.0 20.0 1.14 1.25 0.40 0.60 -30 to +70 3.40 x 3.62 x 1.51 2K 300 1500

9T38 0.198-0.225 24.0 20.0 1.14 1.25 0.40 0.60 -30 to +70 3.40 x 3.62 x 1.51 2K 300 1500

9C25 0.223-0.250 24.0 20.0 1.14 1.25 0.40 0.50 -30 to +70 3.00 x 3.00 x 1.10 2K 300 1000

9C26 0.248-0.278 24.0 20.0 1.14 1.25 0.40 0,50 -30 to +70 3.00 x 3.00 x 1.10 2K 300 1000

9C67 0.270-0.290 28.0 23.0 1.08 1.15 0.18 0.25 -30 to +70 3.00 x 3.00 x 1.10 2K 250 1000

9C21 0.276-0.329 24.0 20.0 1.14 1.22 0.35 0.40 -30 to +70 3.00 x 3.00 x 1.10 2K 250 1000

9C68 0.325-0.360 24.0 20.0 1.14 1.25 0.40 0.50 -30 to +70 3.00 x 3.00 x 1.10 2K 175 1000

9C69 0.350-0.400 24.0 20.0 1.14 1.25 0.40 0.50 -30 to +70 3.00 x 3.00 x 1.10 2K 175 1000

9C70 0.395-0.447 24.0 23.0 1.12 1.15 0.28 0.30 -30 to +70 3.00 x 3.00 x 1.25 2K 175 1200

9C71 0.403-0.524 19.0 17.0 1.25 1.35 0.50 0.60 -30 to +70 3.00 x 3.00 x 1.25 2K 175 1200

9C73 0.490-0.560 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 2.50 x 2.50 x 1.25 2K 175 800

9C74 0.550-0.620 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 2.50 x 2.50 x 1.25 2K 175 800

9C75 0.610-0.680 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 2.50 x 2.50 x 0.50 2K 175 800

9C76 0.670-0.740 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 2.50 x 2.50 x 1.25 2K 175 800

9C77 0.730-0.800 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 2.50 x 2.50 x 1.25 2K 175 800

9A47 0.790-0.960 24.0 20.0 1.14 1.25 0.40 0.50 -30 to +70 1.25 x 1.25 x 0.75 1.5K 175 150

9C78 0.800-0.900 25.0 23.0 1.12 1.15 0.25 0.30 -30 to +70 1.50 x 1.50 x 1.02 1.5K 175 250

9C79 0.900-1.000 25.0 23.0 1.12 1.15 0.25 0.30 -30 to +70 1.50 x 1.50 x 1.02 1.5K 175 250

NOTE: Heat sink temperature must not exceed the maximum operating temperature specified. (continued)

Page 5: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 3

RFS FER

ROCOM COAXIAL ISOLA

TORS/CIRCULA

TORS

COAXIAL ISOLATORS/CIRCULATORS

Product Specifications (continued)

Model Frequency, Isolation VSWR Insertion Loss Operating Dimensions Power, Power, Weight,Number GHz Typ, dB Min, dB Typ Max Typ, dB Max, dB Temperature, C (A x B x C), in Peak, W Avg, W G

9C80 0.95-1.225 20.0 18.0 1.25 1.30 0.30 0.40 -30 to +70 1.50 x 1.50 x 0.75 250 100 200

9A81 1.00-1.20 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 1.25 x 1.25 x 0.75 250 100 150

9A82 1.20-1.40 24.0 20.0 1.14 1.25 0.30 0.40 -30 to +70 1.25 x 1.25 x 0.75 250 100 150

9A83 1.35-1.85 20.0 18.0 1.25 1.30 0.35 0.50 -30 to +70 1.25 x 1.25 x 0.75 250 100 150

20A137 1.60-1.80 24.0 20.0 1.14 1.22 0.30 0.40 -30 to +70 1.00 x 1.00 x 0.50 200 100 50

20A100 1.70-2.00 25.0 21.0 1.12 1.20 0.20 0.30 -30 to +70 1.00 x 1.00 x 0.50 200 100 50

20A2 2.00-2.30 25.0 21.0 1.12 1.20 0.20 0.30 -30 to +70 1.00 x 1.00 x 0.50 200 100 50

20A111 2.30-2.70 24.0 20.0 1.14 1.22 0.30 0.40 -30 to +70 1.00 x 1.00 x 0.50 200 100 50

20B1 1.70-2.30 23.0 20.0 1.15 1.22 0.25 0.30 -30 to +70 1.63 x 1.63 x 0.75 100 25 225

20E26 1.70-2.30 24.0 20.0 1.14 1.22 0.20 0.25 -10 to +85 2.00 x 2.13 x 1.00 100 25 300

20E19 1.70-2.10 25.0 20.0 1.14 1.22 0.20 0.25 -10 to +85 2.00 x 2.13 x 1.00 100 25 300

20E49 1.70-2.70 23.0 20.0 1.15 1.22 0.20 0.25 -10 to +85 2.00 x 2.13 x 1.00 100 25 300

20B29 2.00-3.00 23.0 20.0 1.15 1.25 0.30 0.40 0 to +50 1.63 x 1.63 x 0.75 100 25 225

24A13 2.50-3.50 23.0 20.0 1.15 1.25 0.30 0.40 -20 to +65 1.63 x 1.63 x 0.75 100 25 225

40B74 2.80-3.50 23.0 20.0 1.15 1.25 0.30 0.40 -20 to +65 1.00 x 1.00 x 0.50 100 25 50

40A13 3.40-4.20 23.0 20.0 1.15 1.22 0.25 0.30 -20 to +65 0.75 x 0.88 x 0.50 100 25 40

40B54 3.60-4.20 28.0 26.0 1.08 1.15 0.15 0.17 -20 to +65 1.00 x 1.00 x 0.50 100 25 50

40B48 3.70-4.80 24.0 21.0 1.14 1.20 0.30 0.35 -20 to +65 1.00 x 1.13 x 0.50 100 25 75

40B63 4.40-5.00 28.0 23.0 1.08 1.15 0.18 0.20 -20 to +65 1.00 x 1.13 x 0.50 100 25 75

40B89 5.00-6.00 26.0 23.0 1.10 1.15 0.18 0.20 -20 to +65 1.00 x 1.13 x 0.50 100 25 75

45B19 5.40-5.90 26.0 20.0 1.10 1.25 0.25 0.30 -20 to +65 0.75 x 0.75 x 0.50 100 25 30

51A28 5.80-6.50 26.0 21.0 1.10 1.20 0.30 0.35 -20 to +65 0.50 x 0.63 x 0.50 100 25 20

40B75 5.90-7.125 26.0 23.0 1.10 1.15 0.18 0.20 -20 to +65 1.00 x 1.13 x 0.50 100 25 75

60A74 5.90-8.50 23.0 20.0 1.15 1.25 0.25 0.30 -20 to +65 0.75 x 0.88 x 0.50 100 15 40

60D166 6.80-8.20 23.0 20.0 1.15 1.22 0.35 0.40 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60A81 6.80-8.50 23.0 20.0 1.15 1.25 0.30 0.35 -30 to +70 0.75 x 0.88 x 0.50 100 15 40

60B59 7.10-8.50 26.0 20.0 1.10 1.25 0.25 0.30 -30 to +70 0.63 x 0.75 x 0.50 100 10 25

60A82 8.00-10.00 26.0 20.0 1.10 1.25 0.30 0.35 -30 to +70 0.75 x 0.88 x 0.50 100 15 40

60D157 9.00-11.00 28.0 23.0 1.08 1.15 0.30 0.40 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60D218 10.40-11.70 26.0 21.0 1.10 1.20 0.22 0.25 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60D149 10.70-12.75 24.0 21.0 1.14 1.20 0.25 0.30 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60D150 10.70-13.30 23.0 21.0 1.15 1.20 0.35 0.40 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60D168 11.70-12.20 28.0 23.0 1.08 1.15 0.18 0.20 -30 to +70 0.50 x 0.63 x 0.50 100 10 20

60D169 13.00-16.00 24.0 20.0 1.14 1.25 0.35 0.40 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D123 14.00-14.50 30.0 26.0 1.06 1.15 0.25 0.30 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D219 15.00-18.00 23.0 20.0 1.15 1.25 0.35 0.40 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D172 17.50-19.70 23.0 20.0 1.15 1.22 0.40 0.50 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D165 17.90-21.20 23.0 20.0 1.15 1.30 0.40 0.50 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D173 21.20-23.60 23.0 20.0 1.15 1.22 0.40 0.50 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

60D220 23.00-26.50 23.0 20.0 1.15 1.25 0.40 0.50 -30 to +70 0.50 x 0.63 x 0.50 50 5 20

NOTE: Heat sink temperature must not exceed the maximum operating temperature specified.

Page 6: RFS Ferrocom Catalog

4 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

RFS FER

ROCOM COAXIAL ISOLA

TORS/CIRCULA

TORS

COAXIAL ISOLATORS/CIRCULATORS

Standard coaxial connectors are SMA or Type N, depending on package size.Connectors may be captivated orremovable, male or female,according to application.

Please specify connectortype (SMA, Type N, Special), connector sex(Female, Male) and connector/terminationconfiguration using the below table whenplacing an order.

Connector Option Table

SMA Type “N”Port 1 Port 2 Port 3 Suffix Code Suffix Code

Female Female Termination -01 -11

Termination Female (In) Female (Out) -02 -12

Male Female Termination -03 -13

Termination Male (In) Female (Out) -04 -14

Female Male Termination -05 -1

Termination Female (In) Male (Out) -06 -16

Male Male Termination -07 -17

Termination Male (In) Male (Out) -08 -18

Female (In) Termination Female (Out) -09 -19

Female (In) Termination Male (Out) -10 -20

Termination Male (Out) Male (In) -23 N/A

Female (Out) Termination Female (In) -24 N/A

Female (Out) Termination Male (In) -25 N/A

Male (Out) Termination Male (In) -26 N/A

Male (Out) Termination Female (In) -27 N/A

Male (In) Termination Male (Out) -28 -21

Male (In) Termination Female (Out) -29 -22

Female Female Female -31 -41

Female Female Male -32 -42

Female Male Male -33 -43

Female Male Female -34 -44

Male Male Male -35 -45

Male Male Female -36 -46

Male Female Female -37 -47

Male Female Male -38 -48

SMA Male (In) Type N Female (Out) Termination -39 N/A

Type N Female (In) SMA Male (Out) Termination -40 N/A

SMA Female (In) Type N Female (Out) Termination -49 N/A

Type N Female (In) SMA Female (Out) Termination -50 N/A

Type N Female (In) Type N Male (Out) SMA Female -51 N/A

Type N Male (In) SMA Male (Out) Termination -52 N/A

SMA Female (In) Type N Male (Out) Termination -53 N/A

Termination Male (Out) Female (In) -54 N/A

Type N Male (In) SMA Female (Out) Termination -55 N/A

Termination Female (Out) Male (In) -56 N/A

Page 7: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 5

RFS FER

ROCOM ISODAPTER

S

ISODAPTERS

An isodapter consists of a coaxial isolator or circulator and a waveguide transition.The unit has a combined mechanical structure generally smaller than a normalwaveguide to coaxial adapter and provides good isolation between input andoutput ports. Different waveguide types and connector interfaces are availabledepending on the operating frequency and design availability

• Isolator load rating 10 Watts. Circulator power rated at 2.0:1 mismatch.

• Custom configurations available including various connector types andmultiport options.

• Additional frequencies available.

Model Frequency, Waveguide Mating Isolation VSWR Insertion Loss Operating Dimensions Power, W Weight,Number GHz Type Flange Typ, dB Min, dB Typ Max Typ, dB Max, dB Temp. (A x B x C x D), in Peak Avg G

4701 4.40-5.00 WR187 CMR187 23 20 1.15 1.25 0.3 0.35 -30 to +70 2.37 x 2.78 x 2 x 1.25 100 25 250

6208 5.85-6.50 WR137 CMR137 23 20 1.15 1.25 0.3 0.35 -30 to +70 1.56 x 2.28 x 1.44 x 0.94 100 25 110

6209 5.90-7.125 WR137 CMR137 23 20 1.15 1.25 0.25 0.3 -30 to +70 1.56 x 2.28 x 1.44 x 0.94 100 25 110

6210 6.40-7.125 WR137 CMR137 23 20 1.15 1.25 0.25 0.3 -30 to +70 1.56 x 2.28 x 1.44 x 0.94 100 25 110

6199 7.10-7.75 WR137 CMR137 23 20 1.15 1.25 0.3 0.4 -30 to +70 1.56 x 2.28 x 1.44 x 0.94 100 25 110

6206 7.10-8.30 WR137 CMR137 23 20 1.15 1.25 0.4 0.5 -30 to +70 1.56 x 2.28 x 1.44 x 0.94 100 25 110

7502 7.10-8.50 WR112 UG138/U 23 20 1.15 1.25 0.3 0.4 -30 to +70 1.88 x 1.88 x 1.19 x 1.25 100 25 110

7524 7.10-7.80 WR112 UG138/U 23 20 1.15 1.25 0.3 0.35 -30 to +70 1.88 x 1.88 x 1.19 x 1.25 100 25 110

7525 7.70-8.50 WR112 UG138/U 23 20 1.15 1.25 0.3 0.35 -30 to +70 1.88 x 1.88 x 1.19 x 1.25 100 25 110

9052 8.20-12.40 WR90 UG135/U 23 20 1.15 1.25 0.25 0.3 -30 to +70 1.38 x 1.63 x 1 x 1.02 100 25 100

9055 8.40-970 WR90 UG135/U 23 20 1.15 1.22 0.25 0.3 -30 to +70 1.38 x 1.63 x 1 x 1.02 100 25 100

1130 10.70-11.70 WR75 WR75 23 20 1.15 1.22 0.3 0.35 -30 to +70 1.19 x 1.45 x 1 x 0.56 100 25 80

1274 10.70-13.25 WR75 WR75 21 19 1.15 1.25 0.3 0.4 -30 to +70 1.19 x 1.45 x 1 x 0.56 100 25 80

1123 12.20-13.20 WR75 WR75 23 20 1.15 1.22 0.3 0.35 -30 to +70 1.19 x 1.45 x 1 x 0.56 100 25 80

1573 12.50-15.50 WR62 UG1665/U 23 20 1.15 1.25 0.3 0.4 -30 to +70 1.31 x 1.31 x 1.1 x 0.8 100 25 75

1572 13.30-14.00 WR62 UG1665/U 23 20 1.08 1.15 0.3 0.4 -30 to +70 1.52 x 1.31 x 1.07 x 1.13 100 25 75

1574 14.00-14.50 WR62 UG1665/U 26 23 1.08 1.15 0.3 0.4 -30 to +70 1.52 x 1.31 x 1.07 x 1.13 100 25 75

1872 17.70-19.70 WR42 UG597/U 23 20 1.15 1.22 0.4 0.5 -30 to +70 1.19 x 0.88 x 0.75 x 0.82 100 25 75

2279 19.70-20.70 WR42 UG597/U 23 20 1.15 1.22 0.4 0.5 -30 to +70 1.19 x 0.88 x 0.75 x 0.82 100 25 75

2278 21.20-23.60 WR42 UG597/U 23 20 1.15 1.22 0.4 0.5 -30 to +70 1.19 x 0.88 x 0.75 x 0.82 100 25 75

Product Specifications

NOTE 1: Heat sink temperature must not exceed the maximum operating temperature specified.NOTE 2: Type of connectors, connector/termination configuration and port designation (Input, Output) must be specified when placing an order.

Page 8: RFS Ferrocom Catalog

6 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

RFS FER

ROCOM R CLA

SS DROP-IN ISOLA

TORS/CIRCULA

TORS

R CLASS DROP-IN ISOLATORS/CIRCULATORS

This is the most commonly used isolator and circulator onapplications operating from 1 GHz to 30 GHz. These devicesoffer excellent electrical performance with low insertion loss, lowinter-modulation and temperature stability in addition to ruggedmechanical package featuring a machined housing. Easyintegration and adaptability to manufacturing solder reflowprocess are key attributes of these versatile devices.

• Custom designs available.

• Superior IMD performance available.

• Excellent phase characteristics available.

• Circulator power rated into 2.0:1 mismatch.

Product Specifications

Model Number Frequency, Isolation VSWR Insertion Loss Operating Power, Power, Weight, OutlineCirculator Isolator GHz Typ, dB Min, dB Typ Max Typ, dB Max, dB Temperature, C Peak, W Avg, W G Number

3RC100 2RI100 .800-.900 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 500 50 50 1 & 2

3RC101 2RI101 .900-1.00 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 500 50 50 1 & 2

3RC102 2RI102 1.00-1.20 22.0 20.0 1.17 1.25 0.40 0.50 -30 to +70 500 50 50 1 & 2

3RC103 2RI103 1.20-1.40 22.0 20.0 1.17 1.25 0.40 0.50 -30 to +70 500 50 50 1 & 2

3RC104 2RI104 1.40-1.60 22.0 20.0 1.17 1.25 0.40 0.50 -30 to +70 500 50 50 1 & 2

3RC105 2RI105 1.60-1.80 22.0 20.0 1.17 1.25 0.40 0.50 -30 to +70 500 50 50 1 & 2

3RC106 2RI106 1.80-1.90 22.0 20.0 1.17 1.25 0.25 0.30 -30 to +70 500 50 20 3 & 4

3RC107 2RI107 1.90-2.00 22.0 20.0 1.17 1.25 0.25 0.30 -30 to +70 500 50 20 3 & 4

3RC108 2RI108 2.00-2.10 22.0 20.0 1.17 1.25 0.25 0.30 -30 to +70 250 25 20 3 & 4

3RC109 2RI109 2.10-2.30 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 250 25 20 3 & 4

3RC110 2RI110 2.30-2.50 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 250 25 20 3 & 4

3RC111 2RI111 2.50-2.70 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 20 3 & 4

3RC112 2RI112 2.70-2.90 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 20 3 & 4

3RC113 2RI113 3.40-4.20 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 20 3 & 4

3RC114 2RI114 4.20-4.40 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 6.5 5 & 6

3RC115 2RI115 4.40-5.00 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 6.5 5 & 6

3RC116 2RI116 5.40-5.90 22.0 20.0 1.17 1.25 0.30 0.40 -30 to +70 100 10 6.5 5 & 6

3RC117 2RI117 5.80-6.50 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 100 10 6.5 5 & 6

3RC118 2RI118 6.40-7.20 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 50 10 6.5 5 & 6

3RC119 2RI119 7.80-8.50 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 50 10 6.5 5 & 6

– 2RI120 9.00-10.00 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 25 2 5.0 7

– 2RI121 10.00-11.00 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 25 2 3.5 8

– 2RI122 10.95-12.75 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 25 2 3.5 8

– 2RI123 14.00-14.50 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 25 2 3.5 8

– 2RI124 14.50-15.50 22.0 20.0 1.17 1.25 0.35 0.40 -30 to +70 25 2 3.5 8

– 2RI125 17.70-19.70 22.0 20.0 1.17 1.25 0.50 0.60 -30 to +70 25 2 3.5 8

NOTE: Heat sink temperature must not exceed the maximum operating temperature specified.

Page 9: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 7

FERROCOM R CLA

SS DROP-IN ISOLA

TORS/CIRCULA

TORS

R CLASS DROP-IN ISOLATORS/CIRCULATORS

Page 10: RFS Ferrocom Catalog

8 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

FERROCOM R CLA

SS DROP-IN ISOLA

TORS/CIRCULA

TORS

R CLASS DROP-IN ISOLATORS/CIRCULATORS

Page 11: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 9

RFS FER

ROCOM S CLA

SS DROP-IN ISOLA

TORS/CIRCULA

TORS

Model Number Frequency, Isolation VSWR Insertion Loss Operating Power, Power, Weight, Outline Circulator Isolator GHz Typ, dB Min, dB Typ Max Typ, dB Max, dB Temperature, C Peak, W Avg, W G Iso Circ

3SC100 – 0.132-0.174 17.0 16.0 1.35 1.40 0.60 0.70 -10 to+60 200 100 150 – 7

3SC101 – 0.132-0.154 22.0 18.0 1.18 1.29 0.60 0.70 -30 to +80 250 150 150 – 7

3SC102 – 0.150-0.174 22.0 18.0 1.18 1.29 0.60 0.70 -30 to +80 250 150 150 – 7

3SC103 – 0.170-0.190 23.0 20.0 1.15 1.22 0.50 0.70 -30 to +80 250 150 150 – 7

3SC104 – 0.185-0.210 23.0 20.0 1.15 1.22 0.50 0.70 -30 to +80 250 150 150 – 7

3SC105 – 0.205-0.230 23.0 20.0 1.15 1.22 0.50 0.70 -30 to +80 250 150 150 – 7

3SC106 2SI106 0.225-0.255 23.0 20.0 1.15 1.22 0.50 0.70 -30 to +80 250 150 150 6 7

3SC107 2SI107 0.250-0.275 23.0 20.0 1.15 1.22 0.50 0.70 -30 to +80 250 150 150 6 7

3SC108 2SI108 0.270-0.290 26.0 23.0 1.10 1.15 0.30 0.40 -30 to +80 500 200 150 6 7

3SC109 2SI109 0.276-0.302 23.0 20.0 1.15 1.22 0.38 0.50 -30 to +80 500 200 150 6 7

3SC110 2SI110 0.300-0.340 23.0 20.0 1.15 1.22 0.35 0.45 -30 to +80 500 200 150 6 7

3SC111 2SI111 0.335-0.370 24.0 20.0 1.13 1.22 0.35 0.50 -30 to +80 500 200 150 6 7

3SC112 2SI112 0.350-0.405 24.0 20.0 1.13 1.25 0.35 0.50 -30 to +80 500 200 150 6 7

3SC113 2SI113 0.400-0.475 24.0 20.0 1.13 1.22 0.35 0.50 -30 to +80 500 200 150 6 7

3SC114 2SI114 0.470-0.570 24.0 20.0 1.13 1.22 0.35 0.40 -30 to +80 500 200 150 6 7

3SC115 2SI115 0.560-0.690 22.0 20.0 1.18 1.25 0.40 0.50 -30 to +70 500 200 150 6 7

3SC116 2SI116 0.670-0.806 22.0 20.0 1.18 1.25 0.40 0.50 -30 to +70 500 200 150 6 7

3SC117 2SI117 0.810-0.960 23.0 20.0 1.15 1.22 0.35 0.40 -30 to +70 500 200 150 6 7

3SC118 2SI118 0.850-0.960 25.0 20.0 1.12 1.22 0.35 0.40 -30 to +80 500 200 150 6 7

3SC119 2SI119 0.900-1.000 25.0 20.0 1.12 1.22 0.35 0.40 -30 to +80 500 200 150 6 7

Product Specifications

NOTE: Heat sink temperature must not exceed the maximum operating temperature specified.

Ideal for high power applications operating at low frequency from80 MHz to 1 GHz, this type of isolator offers excellent electricalperformance with low insertion loss, and attractive pricing. Usingsheet metal and a stamping process, different shapes are formedwhich provide mechanical package sizes smaller than isolatorsutilizing a machined housing. A tab interface and availablemounting holes make integration easy during assembly.

• Custom designs available.

• Superior IMD performance available.

• Excellent phase characteristics available.

• Circulator power rated into 2.0:1 mismatch.

S CLASS DROP-IN ISOLATORS/CIRCULATORS

Load Rating: 50 wattsOUTLINE 6

OUTLINE 7

Page 12: RFS Ferrocom Catalog

10 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

RFS FER

ROCOM W

AVEG

UIDE ISOLA

TORS/CIRCULA

TORS

WAVEGUIDE ISOLATORS/CIRCULATORS

These types of units exhibit extremely low insertion loss and operate over a wide rangeof frequency from 4 GHz to 40 GHz. Mechanical package sizes and waveguide typesvary depending on the operating frequency. Special sealing is available on units forapplications where RFI (radio frequency interference) leakage and humidity are critical.

• Isolator load rating 2.0 watts to 14.5 GHz, 1.0 watts above.

• Circulator power rated into 2.0:1 mismatch.

• Specify port designated for termination on Isolator application.

• Additional frequencies available. Custom configurations available.

Model Frequency, Waveguide Mating Isolation VSWR Insertion Loss Operating Dimensions Power, W Weight,Number GHz Type Flange Typ, dB Min, dB Typ Max Typ, dB Max, dB Temp. (A x B x C x D), in Peak Avg G

400 3.70-4.20 WR229 CMR229 29 26 1.07 1.08 0.1 0.15 -30 to +70 4.86 x 4.86 x 2 x 3.16 1000 50 800

450 4.40-5.00 WR187 CMR187 29 26 1.07 1.08 0.1 0.15 -30 to +70 4 x 4 x 1.78 x 2.63 500 25 600

672 5.90-6.40 WR137 CMR137 32 28 1.05 1.08 0.1 0.1 -30 to +70 3.25 x 3 x 1.58 x 1.86 500 25 250

673 6.40-7.125 WR137 CMR137 32 28 1.05 1.08 0.1 0.1 -30 to +70 3.25 x 3 x 1.58 x 1.86 500 25 250

674 5.90-7.125 WR137 CMR137 32 28 1.05 1.08 0.15 0.2 -30 to +70 3.25 x 3 x 1.58 x 1.86 500 25 250

745 7.10-8.50 WR112 UG138/U 30 26 1.06 1.1 0.15 0.2 -30 to +70 2.63 x 2.5 x 1.88 x 1.52 500 25 300

746 7.10-7.80 WR112 UG138/U 32 28 1.05 1.08 0.15 0.2 -30 to +70 2.63 x 2.5 x 1.88 x 1.52 500 25 300

747 7.80-8.50 WR112 UG138/U 32 28 1.05 1.08 0.15 0.25 -30 to +70 2.63 x 2.5 x 1.88 x 1.52 500 25 300

1015 10.00-11.00 WR90 UG135/U 26 20 1.1 1.22 0.18 0.3 -30 to +70 2.25 x 2.25 x 1.63 x 1.44 500 10 125

1016 10.70-11.70 WR90 UG135/U 26 20 1.1 1.22 0.18 0.3 -30 to +70 2.25 x 2.25 x 1.63 x 1.44 500 10 125

1200 10.70-13.25 WR75 WR75 30 26 1.06 1.1 0.18 0.3 -30 to +70 1.75 x 1.75 x 1.5 x 0.97 500 10 140

1221 10.70-11.70 WR75 WR75 32 28 1.05 1.08 0.18 0.3 -30 to +70 1.75 x 1.75 x 1.5 x 0.97 500 10 140

1218 10.95-12.75 WR75 WR75 30 26 1.06 1.1 0.18 0.3 -30 to +70 1.75 x 1.75 x 1.5 x 0.97 500 10 140

1500 12.40-18.00 WR62 UG1665/U 19 18 1.25 1.3 0.18 0.3 -30 to +70 1.5 x 1.5 x 1.32 x 0.85 500 10 200

1509 14.00-16.00 WR62 UG1665/U 23 20 1.15 1.22 0.15 0.2 -30 to +70 1.5 x 1.5 x 1.32 x 0.85 500 10 200

1800 17.70-19.70 WR42 UG597/U 23 20 1.15 1.22 0.18 0.3 -30 to +70 1 x 1.15 x 0.88 x 0.71 250 5 50

2200 21.20-23.60 WR42 UG597/U 26 23 1.1 1.15 0.18 0.3 -30 to +70 1 x 1.15 x 0.88 x 0.71 250 5 50

2213 17.70-23.60 WR42 UG597/U 22 19 1.17 1.25 0.18 0.3 -30 to +70 1 x 1.15 x 0.88 x 0.71 250 5 50

2025 18.00-22.50 WR42 UG597/U 21 19 1.2 1.25 0.18 0.3 -30 to +70 1 x 1.15 x 0.88 x 0.71 250 5 40

2964 25.00-28.00 WR28 UG599/U 24 21 1.13 1.2 0.15 0.2 -30 to +70 0.9 x 0.9 x 0.9 x 0.52 250 5 40

2965 28.00-30.00 WR28 UG599/U 24 21 1.13 1.2 0.15 0.2 -30 to +70 0.9 x 0.9 x 0.9 x 0.52 250 5 40

3500 33.00-37.00 WR28 UG599/U 24 21 1.13 1.2 0.18 0.3 -30 to +70 0.9 x 0.9 x 0.9 x 0.52 250 5 40

3851 37.00-40.00 WR28 UG599/U 23 20 1.15 1.25 0.18 0.3 -30 to +70 0.9 x 0.9 x 0.9 x 0.52 250 5 40

Product Specifications

NOTE: Heat sink temperature must not exceed the maximum operating temperature specified.

Page 13: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com 11

RFS FER

ROCOM 4 PORT COAXIAL ISOLA

TORS/CIRCULA

TORS

4 PORT COAXIAL ISOLATORS/CIRCULATORS

These isolators and circulators provide good signal linearity to the system with highisolation performance, a critical specification for having low reverse or backwardinter-modulation. High power handling capability and low insertion loss make thesedevices attractive for public safety and two-way radio applications.

• Circulator power rated into 2.0:1 mismatch

• Additional frequencies available

• Custom configuration available including various connector types

Model Frequency, Return Loss, Insertion Loss, Isolation, Operating Temperature, Input Power, W Dimensions, inNumber GHz Min., dB Max., dB Min., dB degrees C PK AVG A B C

B187 0.137-0.148 20.0 1.50 40.0 -30 to +85 2K 350 7.00 3.75 1.50

B188 0.142-0.152 20.0 1.50 40.0 -30 to +85 2K 350 7.00 3.75 1.50

B189 0.152-0.167 20.0 1.20 40.0 -30 to +85 2K 350 7.00 3.75 1.50

B190 0.162-0.175 20.0 1.20 40.0 -30 to +85 2K 350 7.00 3.75 1.50

B183 0.380-0.433 19.0 1.00 40.0 -30 to +85 2K 175 4.00 2.30 1.18

B184 0.403-0.470 19.0 1.00 45.0 -30 to +85 2K 175 5.00 2.90 1.02

B185 0.806-0.869 22.0 .60 45.0 -30 to +85 2K 175 4.50 2.50 1.38

B186 0.869-0.960 22.0 .60 45.0 -30 to +85 2K 175 4.50 2.50 1.38

Specifically

designed for

public safety

applications

Product Specifications

ISOLATOR

PORT 3 AND 4 CAN BE TERMINATED WITH A LOAD AS SHOWN

STANDARD LOAD IS 30W (SHOWN)

CIRCULATOR

NOTE: Heat sink temperature must not exceed the maximum operating temperature of +85 C.

Page 14: RFS Ferrocom Catalog

12 RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

RFS FER

ROCOM ORDER

INFO

RMATION

ORDER INFORMATION

Fer rocom Fer r i te D iv i s ion

Frequency Range

Standard products are offered in thefrequency range of 80 MHz to 40 GHz. Asampling of available units is listed on theprevious pages.

Power

Power handling capabilities are as statedon preceding pages. Many applicationshave been developed with peak powerlevels up to 2 kW and CW levels up to500 watts.

Connectors

Standard coaxial connectors are SMA orType N, depending on package size.Connectors may be captivated orremovable, male or female, according to application. Other connector optionsare available.

Magnetic Shielding and RFI Shielding

All standard devices are magneticallyshielded and will maintain their specifiedperformance when operated within adistance equal to its own thickness froma steel plate.

All standard devices are RFI shielded witha typical rating of 40 dB below signallevel. Improved RFI shielding up to 70 dBis available upon request. For RFIrequirements in excess of 70 dB, pleasecontact our sales department.

Quality Assurance

All RFS Ferrocom products are designedand manufactured in accordance to MIL-I-45208A. Our facility is registered to the ISO-9001/2008 quality standard.

All devices are individually tested toassure compliance with guaranteedelectrical and mechanical specifications.Each shipment is accompanied by acertificate of compliance. Complete testdata is available upon request.

Specifications

In keeping with our policy of continuousproduct improvement, RFS Ferrocomreserves the right to changespecifications without notice.

Custom Engineering

Custom design capabilities are availableto provide a wide range of solutions toyour ferrite requirements. Please contactour sales department with yourspecifications today. This includes custompackaging, custom connector or cableconfigurations, unique electricalrequirements, or enhanced performancespecifications.

Price and Delivery

Price and delivery information may beobtained from your nearest RFS Ferrocomsales representative or directly from thefactory sales department at:

RFS Ferrocom Ferrite Products6276 San Ignacio Avenue, Suite ESan Jose, CA 95119Phone: 408.281.6100Fax: 408.281.4000E-mail: [email protected]

Warranty

RFS Ferrocom products are warranted tothe original purchaser to be free ofworkmanship or material defects for aperiod of three years from the date ofshipment. Warranty void if device isdisassembled or misused. RFS Ferrocomobligation is limited to repair orreplacement.

Page 15: RFS Ferrocom Catalog

RADIO FREQUENCY SYSTEMS 6276 San Ignacio Avenue, Suite E, San Jose, CA 95119 Phone 408.281.6100 Fax 408.281.4000 Website www.rfsworld.com

REQUEST FOR QUOTATION ORDER GUIDE

Your Name:

Company:

Address:

City: State:

Country: Postal Code/Zip:

Phone:

Fax:

E-mail:

ISOLATOR CIRCULATOR

PRODUCT INFORMATION

CUSTOMER INFORMATION

ISODAPTER WAVEGUIDE

COAXIAL DROP-IN

Model #: Customer SCD#:

Quantities:1st Choice 2nd Choice 3rd Choice

Request Date: Delivery Date:

Frequency: GHz Peak Power: Watts

Isolation: dB Min. Termination Rating: Watts

Return Loss: dB Min. Operating Temp.: ° C

Insertion Loss: dB Max. Storage Temp.: ° C

Avg. Power: Watts Shielding: dBc

Notes:

CONNECTOR TYPE

Input Port 1:

Input Port 2:

Input Port 3:

SMA TYPE N SPECIAL TAB LOAD N/A

CONNECTOR GENDER

Input Port 1:

Input Port 2:

Input Port 3:

FEMALE MALE TERMINATION N/A

1 2

3

This form is also available on-line at www.rfsworld.com

13

RFS FER

ROCOM RFQ

ORDER

GUIDE

Page 16: RFS Ferrocom Catalog

www.rfsworld.com

© 2011 Radio Frequency Systems – 5/11Fer rocom Fer r i te D iv i s ion