ABOUT REZNOCLADReznoclad is self-supporting high pressure laminate (HPL) with a decorative surface that is suitable for exteriors. It is fade resistant weather-proof and complies with standard EN 438.

It is entirely made up of layers of phenolic resin & impregnated craft papers with top decorative layer and UV protective film.

The manufacturing process involves the combining of papers with oapplications of high heat (150 c) and high pressure (9 Mpa) in which

resin polycondensation takes place. One or both sides can be decorative mixed with the phenolic resins.

exterior hpl

R

01

Page 3: Reznoclad Brochure final_2016

TYPES OF EXTERIOR PANELSREZNOCLAD panels are available in the following grades for their

suitability as per the required applications.

• Exterior Cladding Panels (Fire Retardant)

• Exterior Cladding Panels

• Exterior Cladding Panels (With Anti-graffiti)

• Wall and facade linings • Cladding or exhibition building

• Sporting and entertainment complexes

• Decoration of commercial sites • Residential dwellings

• silhouette profiles • fences • Facade Claddings

• Balcony Claddings • Partitions • Rear ventilated facades

• Ceilings • Outdoor furniture • Public facilities

• Playground facilities • Sport facilities • Sun protection

• Business entry portals • Functional constructions

• Attic Cladding • Awnings

REZNOCLAD panels are extremely durable with

international styling and a wide range of colours

available on both horizontal and vertical designs. Its

excellent technical properties make it suitable for the

building industries as an ideal alternative to traditional

materials.

APPLICATION

exterior hpl

R

02

Page 4: Reznoclad Brochure final_2016

CHARACTERISTICS

CLEANING & MAINTENANCE

HANDLING & STORAGESReznoclad panel comes with a film on top layer for protection during transportation. During

stocking, panels must be stacked horizontally on flat, stable shelfs, the panels to be stored in

closed rooms under dry, normal climatic conditions. Cover plates must always be left on the stack.

The cover should be weighted down. Any form of dirt or dust between the panels must definitely

be avoided. Panels must be lifted and not pushed or pulled over the edge when carrying or

loading.

For climate differences, keep panels waiting for 24 hours in new climate conditions. With pre-

installed fastering elements, care is to be take that the climatic effect is uniform on all sides. Use

intermediate layers of wood or plastic.

REGULAR SIZES

The protective film applied at factory must

be removed from the surface of the panel

immediately after installation to the facade.

The surface of reznoclad panels repels dust,

however over the time it may be necessary

to clean their surface with soapy water for

better aesthetic over time.

WARRANTIESThanks to practical experience over many

year and the high quality of Reznoclad HPL

Panels, warranties are available both for

the product range in general and for

specific projects. More information can be

obtained from your local representative.

3050*1300*6mm2440*1220*6mm

Thickness

On demand: 4 to 20mm

Grain direction

Easy to Clean

Moisture Resistance

StrikeResistance

Chemical Effects Resistance

AbrassionResistance

High Heat & Fire Resistance

Ÿ

Ÿ Resistance to atmospheric conditions

Ÿ Resistance to swelling in boiling water

Ÿ Fire-resistance

Ÿ Physical resistance to strikes and abrasion

Ÿ Chemical resistance to mild acids, rain, air

pollution

Ÿ Wide range of colors and patterns

Ÿ Easy to care and repair

Ÿ Do not contain any harmful substances

Resistance to UV rays

Ÿ

Ÿ Overall lightweight substructure and facade

Ÿ dimensional stability and flatness

Ÿ Light weight facade system

Ÿ Easier perforation

Maximum light fasten

exterior hpl

R

03

Page 5: Reznoclad Brochure final_2016

EXTERIOR CLADDING

FIXING METHOD

The lap Sliding Fixing Method has the advantage of being a very

attractive system of panel fixing. With pre-fabricated REZNOCLAD

Exterior Cladding panels for the lap sidings. It is easy to design

robust and modern facades. Besides the regular advantages of

REZNOCLAD Exterior Cladding panels, This lap siding panels looks

more eye catching.

MOUNTING INSTRUCTIONS

1. Preparing The Substructure

REZNOCLAD lap siding panels are installed using mounting clips fixed to a sub-structure of vertical wooden slats. Each slat must be at least 50 mm wide where two panels join to allow enough space for two mounting clips side by side. The gap between each slat should not exceed 500 mm as applicable to low building of up to 8m height. The panels are installed starting from the bottom. First of all, fit a horizontal base bar. Now fit the first row of mounting clips so they rest on the bar. Make sure you fit 2 mounting clips at each vertical joint between panels.

2. Installing the first row of panels

Place the groove along the lower edge of the REZNOCLAD lop siding panels onto the mounting clips. Secure the panels in place by fixing mounting clips along the lop edge of each panel. The panel above overlaps the first row of panels by approximately 25 mm. Fit a screw next to the lop middle mounting clip on each panel. This is designed to stop the sideways shifting of panels

3. Vertical joints

A slot for Fixing the mounting clips must be located at each vertical joint. Two mounting clips, one either side of the joint, ore needed to provide the necessary hold. Please use proper backing strips to seal the vertical Joint between cladding panels. If the siding elements ore arranged so the vertical Joints ore offset then it is sufficient to install the panel plus backing strip using o single mounting clip. If the vertical joints are in a line then two mounting clips need to be used. There must be a gap of at least 8 mm between the panels at the joint.

4. Outside corners/Inside corners with mitre

REZNOCLAD lap siding panels can be mitred lor both outside and inside corners. Outside corners: The lap edge of the panel must be 12 mm shorter than the lower edge of the poneI (regardless of the panel width). Inside corners: The lower edge of the panel must be 12 mm shorter than the top edge of the panel (regardless of the panel width). The mitred edges must hove a chamfer. Thesub-struclure needs to be protected with a plastic sheet to prevent water entering. Elements can be installed on both outside and inside corners using a variety of shapes of corner profile. In this case the panels ore cut to size without a mitre. Please make sure there is a gap of at least 5 mm between each panel and the corner profile.

5. Installing the top row of panels

Secure the top row of panels by fitting screws along the top edge of each panels. Use screws with painted heads to match the color of the panels, as used for the installation of full-sized Samrat exterior Cladding panels.

exterior hpl

R

04

Page 6: Reznoclad Brochure final_2016

ENVIRONMENTReznoclad is committed to continuous improvement of

environmental performances. These panels are not hazardous

to health and does not pollute the environment. It is made up

of 70% cellulose fibers and 30% thermosetting resins and does

not contain asbestos or heavy metals. These panels does not

emit gases, fumes, solvents or liquid substances.

Fixing Details Installation System

RIVET FIXING SYSTEM

exterior hpl

R

05

Page 7: Reznoclad Brochure final_2016

Woody Streaks 9363 Canyon Monument Oak 9391

American Elm 9354Light Knotty Pine 9322

Princess WalnutArizona Walnuts 9334 9383

Grey Monument OakWisconsin Walnut 9345 9394

exterior hpl

R

06

Page 8: Reznoclad Brochure final_2016

9351Brunt Wood9320Mustard Aquatone

9395Straight Wenge9394Oxford Cherry

9381Bengali Mango Dark 9384Versailles Walnut

9807Travetine Marble9806Gold Spray

exterior hpl

R

07

Page 9: Reznoclad Brochure final_2016

9422White

9420Frosty White 9421Smoke Grey

9425Black

9423Slate

9424Coffee

exterior hpl

R

08

Page 10: Reznoclad Brochure final_2016

REZNOCLAD PROJECTS

TECHNICAL SPECIFICATION

S. No. PROPERTIES

TEST METHOD

ATTRIBUTES OF PERFORMANCE

UNITS OF MEASUREMENT

RESULTS (AS PER EN438-6)

1. Surface Quality

1.1 Surface Quality EN 438-2.4 Spots, dirt and similar surface 2 2mm /m 2

202 2mm /mFibres, hairs & scratches

Dimensional Properties

Thickness

Size

Straightness of edge

Squareness

Flatness

EN 438-2.5

EN 438-2.6

EN 438-2.7

EN 438-2.8

EN 438-2.9

2.

2.1

2.2

Thickness Tolerance

Length and Width

Straightness of edges

Squareness

Flatness (measured on full-size sheet)

mm

mm

mm/m

mm/m

mm/m

5 T 8:+ 0, 4

+10/-0

1,5

1,5

6.0 T 10,0:5

Physical Properties 3.

3.1

3.2

3.3

3.4

3.5

3.6

3.7

4.

4.1

4.2

5.

5.1

EN ISO 1 78

EN ISO 1 78

EN ISO 527-2

EN ISO 1183

EN 438-2.21

EN 438-2.15

EN 438-2.17

EN 438-2.19

EN 438-2.29

EN 135 01

Stress

Stress

Stress

Density

Indent dia. 10mm 2 T < 6mm

Drop Height

Indent dia. 10mm T 6mm -

Drop Height

Mass increase - 2 T < 5mm

Mass increase - T 5mm

Appearance

Cumulative dimensional

change -2 T 5mm

Cumulative dimensional

change -T 5mm

Thermal Shock Resistance-

Appearance

Contrast

Appearance

Test as per EN 13823 (SBI Test) and EN ISO 11925 - 2 (Small-burner Test)

Classification - 3 T < 6mm

Classification - 6 T < 13mm

Mpa

Mpa

Mpa3gm/cm

min.

min.

max.%

max.%

Rating

Longitudinal %

Transversal %

Longitudinal %

Transversal %

Rating

Grey Scale Rating

Rating

Classification

Classification

9000

80

60

1,35

1400

1800

EGS- 7, EGF- 10

EGS- 7, EGF- 10

4

0.40

0.80

0.30

0.60

4

3

4

B-s2, d0

B-s1, d0

Flexual Modulus

Flexual Strength

Tensile Strength

Density

Resistance to impact with

large diameter bill

Resistance to Wet

Conditions

Dimensional Stability at

elevated temperatures

Weather Resistance Requirements

Resistance to Climatic

Shock

Resistance to Artificial

Weathering

Fire Performances

Fire Reaction Classification

PERMEABILITY WATER PROTECTION

THERMAL INSULATION (ELEMENATION OF

HEAT BRIDGE)

SOLAR PROTECTION

ACOUSTICPROTECTION

BREATHABLE FACADE FOR HEALTHIER BUILDINGS- REZNOCLAD HPL IS HIGHLY SUITED FOR VENTILATED FACADE SYSTEMS.

exterior hpl

R

09

Page 11: Reznoclad Brochure final_2016

exterior hpl

R

10

Page 12: Reznoclad Brochure final_2016

exterior hpl

R

11