Retrograde Cardioplegia Catheters - Edwards Lifesciences€¦ · Edwards retrograde cardioplegia...

4
Edwards Protection Cannulae Retrograde Cardioplegia Catheters MAXIMIZE MYOCARDIAL PROTECTION A growing body of evidence points to combined retrograde and antegrade cardioplegia as the best approach for maximizing myocardial protection in patients undergoing arrested heart procedures. 1-5 Edwards retrograde cardioplegia catheters are specifically designed to help you protect your patients during on-pump cardiac surgery by maximizing myocardial protection. Edwards retrograde cardioplegia catheters offer a variety of features designed to meet various surgical needs and preferences. Proprietary ergonomic handle provides an anatomically precise path during placement

Transcript of Retrograde Cardioplegia Catheters - Edwards Lifesciences€¦ · Edwards retrograde cardioplegia...

Edwards Protection Cannulae

RetrogradeCardioplegia Catheters

MAXIMIZE MYOCARDIAL PROTECTIONA growing body of evidence points to combined retrogradeand antegrade cardioplegia as the best approach formaximizing myocardial protection in patients undergoingarrested heart procedures.1-5

Edwards retrograde cardioplegia catheters are specificallydesigned to help you protect your patients during on-pumpcardiac surgery by maximizing myocardial protection.

Edwards retrograde cardioplegia catheters offer a varietyof features designed to meet various surgical needs andpreferences.

Proprietary ergonomichandle provides an

anatomically precise pathduring placement

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 2

SELF-INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a self-inflating balloon style, which offersthe convenience of automatic balloon inflation when retrograde cardioplegia is delivered.

Balloon Styles: Balloon Sizes:Available in textured and Multiple balloon sizes ranging from 9 mm to 20 mm tosmooth balloon configurations. accommodate a variety of patient sizes and surgical preferences.

RetrogradeCardioplegia Catheters

Multiple handle and styletoptions to accommodate a variety

of surgical preferences

* Shorter length† Female luer instead of stopcock

Smoothballoon

Texturedballoon

Pre-shapedstylet and

handle

Hourglasshandle andguidewire

styletGuidewirestylet

SPECIFICATIONSCATHETER SIZE 9 FR 12 FR 14 FRBALLOON STYLE Smooth Textured Textured SmoothBALLOON SIZE 9 mm 18 mm 14 mm 18 mm 20 mm 18 mm 20 mmRETENTION Conventional Retractaguard Conventional Retractaguard Conventional Retractaguard Conventional Conventional ConventionalTECHNOLOGY technology technology technologyPRE-SHAPED RC09 RC2012 RC014IT RC2014 RC014T RC2014LB NPC014T RC014 NPC014STYLET AND RC2014S* RC2014LBS*HANDLEGUIDEWIRE RC09M RC2012M - RC2014M RC014MT RC2014LBM - RC014M -STYLET ISP3031†

HOURGLASS - - - ISP3098 - - - - -HANDLE ANDGUIDEWIRESTYLETH

AN

DLE

CON

FIG

URA

TIO

NS

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:47 PM Page 3

MANUALLY INFLATING BALLOONEdwards retrograde cardioplegia catheters are available in a manually inflating balloon style,which offers surgeon control over inflating and deflating the balloon.

Balloon Styles: Body Styles:Available in textured and smooth Available in polyurethane or wire-reinforcedballoon configurations silicone configurations

RETRACTAGUARDTECHNOLOGYThis proprietary technology is designed to help thecannula retain its shape after deployment in thepatient and to help prevent balloon slippage,particularly during posterior graftingprocedures.

† Female luer instead of stopcock

Retractaguardtechnology

HA

ND

LECO

NFI

GU

RATI

ON

S

SPECIFICATIONSCATHETER SIZE 12 FR 14 FRBALLOON STYLE Textured Textured SmoothBODY STYLE Polyurethane Polyurethane Wire-reinforced silicone Wire-reinforced siliconeRETENTION Retractaguard Retractaguard Conventional ConventionalTECHNOLOGY technology technologyPRE-SHAPED RC2012MIBB RC2014MIBB SRT014MIBB RC014MIBBSTYLET ANDHANDLEGUIDEWIRE RC2012MIB RC2014MIB SRT014MIB RC014MIBSTYLET PLD014MIBH†

HOURGLASS - - - ISP3039HANDLE ANDGUIDEWIRESTYLET

Smoothballoon

AR05171_EDW_Spec_Cardio_Retro_1.qxd:Layout 1 6/21/10 3:48 PM Page 4

Edwards Lifesciences LLC | www.edwards.com

Irvine, USA | Nyon, Switzerland | Tokyo, Japan | Singapore, Singapore | Sao Paulo, Brazil |

References:1. Buckberg Gd. Antegrade/Retrograde Blood Cardioplegia to Ensure Cardioplegic Distribution: Operative Techniques

and Objectives. J Card Surg 1989;4(3):216-238.2. Loope Fd, Higgens Tl, Panda R, et al. Myocardial Protection During Cardiac Operations. J Thorac Cardiovasc Surg

1992;104:608-618.3. Buckberg Gd. Myocardial Protection: An Overview. Semin In Thorac Cardiovasc Surg 1993;5(2):98-106.4. Borger MA, Rao V, Weisel RD, et al. Reoperative coronary bypass surgery: Effect of patent grafts and retrograde

cardioplegia. J Thorac Cardiovasc Surg 2001;121:83-90.5. RangarajAT, et al. Real-time visualization and quantification of retrograde cardioplegia delivery using near infrared

fluorescent imaging. J Card Surg 2008;23(6):701-8.

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.See instructions for use for full prescribing information.

Edwards, Edwards Protection Cannulae and Retractaguard are trademarks of Edwards Lifesciences Corporation. EdwardsLifesciences and the stylized E logo are trademarks of Edwards Lifesciences Corporation and are registered in theUnited States Patent and Trademark Office. © 2010 Edwards Lifesciences LLC. All rights reserved. AR05171

0

10

20

30

40

50

60

0 50 100 150 200 250 300

Pres

sure

Dro

p(m

mH

g)

Flow Rate (ml/min), H2O at Room Temperature

Retrograde Cardioplegia CatheterPressure Drop vs. Flow

14 Fr. Self-Inflating,Retractaguard technology

9 Fr. Self-Inflating,Conventional

12 Fr. Self-Inflating,Retractaguard technology

14 Fr. Self-Inflating,Conventional

14 Fr. Manually Inflating,Conventional

12 Fr. Manually Inflating,Retractaguard technology

14 Fr. Manually Inflating,Retractaguard technology

RetrogradeCardioplegia Catheters