Residential LightingLED and CFL Lamps

Regional Technical ForumApril 23, 2014

Page 2: Residential Lighting LED and CFL Lamps

2

LED Measure Overview

• Current Category: Proven

• Current Status: Active

• Current Sunset Date: April 30, 2014

• Reason for Update/Review: Sunset date

Page 3: Residential Lighting LED and CFL Lamps

3

CFL and Specialty CFL Measure Overview

• Current Category: Proven

• Current Status: Active

• Current Sunset Date: January 31, 2017

• Reason for Update/Review: Reduce number of measures (broadermeasure identifiers) Standardize measure identifiers acrossLED and CFL measures.Standardize data sources across LED andCFL measures.

Page 4: Residential Lighting LED and CFL Lamps

4

Background

• CFLs and Specialty CFLs – Most recent update in October, 2013. Sunset date: January 2017

• LEDs – Most recent updates February 2013 and August 2013 (more delivery mechanisms). Sunset date: April 2014.

• RTF Residential Lighting Subcommittee formed in February in preparation for upcoming LED sunset.

Page 5: Residential Lighting LED and CFL Lamps

5

Staff Highlighted Areas (1)• Baseline is RBSA, not current sales. This assumption may not be

accurate given EISA, changes in the market (e.g. there are very few LEDs in RBSA), and large differences in product lifetimes.

• Analysis assumes lumen-for-lumen measures. This hypothesis has not been tested.

• Retail analysis assumes all lamps are used in residential applications. There is anecdotal evidence that as much as 15% of lamps end up in commercial applications (different HOU) (see October 2013 CFL presentation).

• Analysis assumes RBSA incandescent lamps are reduced to EISA standard, NOT to CFLs, as some would assume.

Is there an appetite for sales-volume research to address these uncertainties?

Page 6: Residential Lighting LED and CFL Lamps

6

Staff Highlighted Areas (2)• Data gap filling – Staff have estimated CFL and LED cost

and performance for hypothetical products in order to develop measures for all permutations of measure identifiers. (e.g. LED 3-Way). Is this acceptable? In some cases, the savings are extremely high.

• Storage rate effects - Savings and lifetime are adjusted to account for storage rate, as per the October 2013 RTF decision regarding CFLs.

• Incremental cost is negative for some retail CFLs. Incremental cost is set to $0 for these cases.

• Fixtures are not included in this analysis. Staff plan to develop a separate analysis for LED fixtures.

Page 7: Residential Lighting LED and CFL Lamps

7Current CFL and LED MeasuresCurrent LED Current CFL, CFL Fixture & Specialty CFL

Hours of UseBaseline definitionBaseline lamp wattage RBSA, by tech type, lamp type, room type RBSA, by tech type, lamp type, room typeEE lamp wattage EnergyStar product list BPA Simple Steps program data

Delivery MechanismsRetailDirect InstallMail-by-Request, Give-Away

RetailDirect InstallMail-by-RequestUnsolicited-MailingGive-AwayNEEA Socket Count (no fixtures)

EE Cost PSE 2013 program data BPA Simple Steps program data

Baseline CostInc/Hal - 2013 RTF staff shelf surveyCFL - ETO shelf survey

Inc/Hal - ETO 2012-2013 Shelf SurveyCFL - BPA Simple Steps program data

Lifetime Ceiling at 12 years

CFL - [10,000 hours] * [derating for on/off switching] / [hours per year (by room type)]

Cold Cathode CFL - [25,000 hours] * [derating for on/off switching] / [hours per year (by room type)]

Eligibility

Measure Combinations

Retail/MbR/GA - 18 each = [3 lamp type] x [6 lumen bins]

Direct Install - 756 = [14 room type] x [3 tech type] x [3 lamp type] x [6 lumen bins]

Retail/MbR/GA/Unsolicited Mail - 60 each = [10 lamp type] x [6 lumen bins]

Direct Install - 600 = [5 room type groups] x [2 tech type] x [10 lamp type] x [6 lumen bins]

KEMA & DOE, by room typeRBSA observed mix of inc/hal/CFL

Meets Energy Star criteria.

Page 8: Residential Lighting LED and CFL Lamps

8

March 4, 2014 March 25, 2014Rebecca Blanton (PSE) X XJanice Bowman (Ecova) XAimee Brown (CLEAResult) XRyan Crews (CLEAResult) XRyan Firestone (RTF staff) X XJenni Francis (BPA) X XColin Gibbs (CLEAResult) XEric Koch (Applied Proactive Technologies) X XAaron Milano (PECI) X XHillary Olson (Snohomish PUD) X XNick O’Neil (RTF staff) X XBrien Sipe (CLEAResult) X XJoel Smith (PSE) X XJeremy Stewart (Tacoma Power) X XDavid Thompson (Avista) X XJohn Voldal (Colehour + Cohen) X X

Residential Lighting Subcommittee• Attendance

Page 9: Residential Lighting LED and CFL Lamps

9

Residential Lighting Subcommittee

• Guidance for RTF Staff:– Reduce the number of measures– Standardize measure identifiers across CFL and LED

measures– Use LED cost and performance forecasts (PNNL) for

measure update– Update CFL measure ahead of sunset date to reflect

new measure identifiers– Do not pursue broader categorization (e.g., “Any

LED”) if it would require a provisional measure.

Page 10: Residential Lighting LED and CFL Lamps

10Subcommittee - Measure Grouping• After discussion with the Subcommittee, Staff suggested that the following level of

granularity:

– Existing Technology Type: with EISA standards applied, we’ve seen that Incandescent and Halogen baselines are about the same. It’s OK to group these together.

– Space Type: from what we’ve heard from the subcommittee, these three space types capture their programs and differences in hours-of-use within each category are relatively minor. We expect RBSA to be representative of program activity, so it’s OK to group spaces.

– Lamp Type: this is the level of granularity that we have good data on. – Lumen Category: each lumen category reflects a distinct product

• Subcommittee requested two further reductions to the categorization:– Merge the 6 lumen categories into 3– Merge “Globe” lamp type with “Decorative and Mini-Base”

Existing Technology Type (DI only) Space Type (DI only) Lamp Type Lumen CategoryIncandescent or Halogen Exterior Decorative and Mini-Base 250 to 369 lumensCFL (LED only) Interior, high and medium usage room types General Purpose and Dimmable 370 to 664 lumens

Interior, low usage room types Globe* 665 to 1014 lumensReflectors and Outdoor 1015 to 1439 lumensThree-Way 1440 to 2019 lumens

2020 to 2600 lumens

Page 11: Residential Lighting LED and CFL Lamps

11Subcommittee Lumen Bins – Can we go from 6 to 3?

• The following grouping was proposed:

• But we know that there are distinct products in each of the six RTF lumen categories.

• If we are to group products from two RTF lumen categories into a single lumen category, we need to take weighted average results from two distinct measures. The weighting comes from RBSA, but program weighting may be different.

• The RTF does not have a firm policy on how granular measure identifiers should be, but in general we will forego granularity if it does not alter expected claimed savings by more than 10%.

Current RTF Lumen Categories

Incandescent Equivalent

Wattage Proposed Categories250 to 369 lumens 25W

370 to 664 lumens 40W

665 to 1014 lumens 60W

1015 to 1439 lumens 75W

1440 to 2019 lumens 100W2020 to 2600 lumens 150W

250 - 664 lumens

665 - 1439 lumens

1440 - 2600 lumens

Page 12: Residential Lighting LED and CFL Lamps

12SubcommitteeLumen Bins – Can we go from 6 to 3?

• Staff have devised two tests to see how significant the resolution of our savings estimates is compromised by grouping lumen bins:

• 1) How sensitive are the RBSA results to variation in weighting?– For each pair of measures that would be grouped together:

• Identify the portion of RBSA lamps in both categories• Identify the percentage point difference in program proportions that

would lead to a 10% difference in savings

• 2) How different would program claimed savings be under the two categorization schemes?– For each pair of measures that would be grouped together:

• Identify the percentage change in savings if the program counted savings using one lumen bin, relative to using two lumen bins

Page 13: Residential Lighting LED and CFL Lamps

SubcommitteeLumen Bin Grouping Sensitivity

13

• LED DI measures, incandescent/ halogen baseline

Inc/Hal to LED DI measures are

not very sensitive to

differences in RBSA and program

proportions

This is an example. See subcommittee presentation for full set of results.

Page 14: Residential Lighting LED and CFL Lamps

14

Residential Lighting SubcommitteeConclusions – Measure Identifiers• Moving from 6 lumen categories to 3 looks good.

– This wouldn’t work for a CFL to LED direct install measure. Subcommittee was OK not including this measure for the sake of having less measure identifiers.

– There is some risk of getting the weights wrong on general purpose CFLs, but program data to date shows similar distributions of lamps as RBSA.

• Grouping Globes with Decorative and Mini-base doesn’t look good.

• Grouping 75W equivalent lamps with 60W equivalent lamps has less risk than grouping 75W equivalent lamps with 100W equivalent lamps.

Page 15: Residential Lighting LED and CFL Lamps

15

Residential Lighting Subcommittee

Final Measure IdentifiersExisting Technology Type (DI only) Space Type (DI only) Lamp Type Lumen CategoryIncandescent or Halogen Exterior Decorative and Mini-Base 250 to 664 lumens

Interior, high and medium usage room types General Purpose and Dimmable 665 to 1439 lumensInterior, low usage room types Globe 1440 to 2600 lumens

Reflectors and OutdoorThree-Way

Page 16: Residential Lighting LED and CFL Lamps

16

Methodology – Baseline Determination• For each RBSA record, assign:– EISA / IRL adjusted wattage (based on lamp category,

wattage)

– hours of use, by room type (KEMA, DOE)

– lamp lifetime, by lamp category. • CFLs lifetimes are derated as a function of room type.

– baseline lamp cost, by lamp category and lumen bin. • Incandescent and halogen costs are from the ETO shelf survey,

• CFL and LED costs are from Simple Steps program database (BPA and additional utilities that contract with CLEAResults).

Page 17: Residential Lighting LED and CFL Lamps

17

• For each combination of categories

– Determine the total regional weight of the category.

• The is the product of the number of lamps per fixture, number of fixtures per room, and the site survey weight of each record (i.e. how many bulbs each record represents)

– Determine the weighted average

• Baseline EISA / IRL adjusted wattage

• HOU

• Lifetime

• HVAC interaction applicability (0% for “exterior” and “garage” room types, 100% for all other room types)

• Baseline lamp cost

Methodology – Baseline Determination

Page 18: Residential Lighting LED and CFL Lamps

18

Analysis MapRBSA SF/MF/MH Lighting

RBSA_Lighting_Metatable.xlsx

Residential Lighting Baseline Table 2014_04_07.xlsx

ResLighting_CFLandLEDLamps_v01.xlsx

• Baseline lamp data – efficacy, lifetime, cost

• Lifetime adjustments for CFL switching patterns

• EISA and IRL Specifications• Hours of use by RBSA room

type• Efficient lamp data

• Efficacy (EnergyStar),• Lifetime (EnergyStar)• Cost (programs)• LED efficacy and cost

forecasts (PNNL)

Compiled RBSA data

Complete baseline dataset

Page 19: Residential Lighting LED and CFL Lamps

19Data Availability

How data gaps are handled:• If RBSA data does not exist – set measure savings to zero.• If Energy Star or Simple Steps data does not exist – extrapolate data from similar product (same lamp

type, lower lumens, or different lamp type, same lumens).RTF Decisions: • Should we include measures that we don’t have efficient case data for?• Can we group Three-Way lamps with General Purpose and Dimmable?

Lamp Type Lumen Cateogry

Moderate and High-

use InteriorLow-use Interior Exterior

Energy Star QPL

(efficacy, lifetime)

Simple Steps (cost)

Energy Star QPL

(efficacy, lifetime)

Simple Steps (cost)

250 to 664 lumens 1386 494 70 13 4332 74 0665 to 1439 lumens 353 179 33 1 2572 0 01440 to 2600 lumens 11 5 1 0 0 0 0250 to 664 lumens 1738 934 100 73 8813 64 497665 to 1439 lumens 7807 4623 1025 313 42110 178 8441440 to 2600 lumens 1190 485 153 144 20038 23 0250 to 664 lumens 163 691 9 19 8940 69 144665 to 1439 lumens 143 405 8 13 4959 3 01440 to 2600 lumens 42 17 1 0 0 0 0250 to 664 lumens 235 93 16 25 11910 460 767665 to 1439 lumens 1395 873 442 60 35018 998 22171440 to 2600 lumens 42 80 205 0 10 17 0250 to 664 lumens 6 1 0 0 0 0 0665 to 1439 lumens 105 3 0 0 4816 0 01440 to 2600 lumens 528 46 2 9 3810 0 0

Globe

Reflectors and Outdoor

Three-Way

RBSA (Baseline wattage, HOU, conditioned space) LEDsCFLs

Decorative and Mini-Base

General Purpose and Dimmable

Page 20: Residential Lighting LED and CFL Lamps

20

Measure Analysis and Inputs Details

• Go to the following sections in the Summary tab in the proposed measure workbook:– Constant Parameters– Energy Savings Estimation Method, Parameters

and Data Sources– Measure Incremental Costs and Benefits– Measure Lifetime

Page 21: Residential Lighting LED and CFL Lamps

21

Savings, Cost, & Cost EffectivenessMost significant reasons for differences in current and proposed results:• EISA 2014 Standards - Current LED analysis does not include EISA 2014

standards (60W and 40W equivalent lamps). Proposed LED analysis does. – Current and Proposed CFL analyses include 2014 EISA.

• Lumen-for-lumen handling - Switch from using average wattage from efficient case datasets, to using average efficacy, and lumen matching to average base case.

• IRL Standard - Better handling of Incandescent Reflector Lamp federal standard.

• Imperfect mapping for comparison - Current LED omnidirectional lamp results are compared to proposed General Purpose, Globe, and Three-Way; the current Globe and Three-Way results are heavily influenced by the current General Purpose results.

Page 22: Residential Lighting LED and CFL Lamps

22

Sample of Savings Results• Direct Install, LED

Page 23: Residential Lighting LED and CFL Lamps

23

Sample of Savings Results• Retail, LED

Page 24: Residential Lighting LED and CFL Lamps

24

Sample of Savings Results• Direct Install, CFL

Page 25: Residential Lighting LED and CFL Lamps

25

Sample of Savings Results• Retail, CFL

Page 26: Residential Lighting LED and CFL Lamps

26

Sample of TRC BC Results• Direct Install, LED

Page 27: Residential Lighting LED and CFL Lamps

27

Sample of TRC BC Results• Retail, LED

Page 28: Residential Lighting LED and CFL Lamps

28

Sample of TRC BC Results• Direct Install, CFL

Y-axis capped at 10

Page 29: Residential Lighting LED and CFL Lamps

29

Sample of TRC BC Results• Retail, CFL

Y-axis capped at 10

Page 30: Residential Lighting LED and CFL Lamps

30

Savings, Cost, & Cost Effectiveness

• Pivot charts are included in the Measure Assessment Workbook to view Savings, Cost, and Cost-effectiveness for all Delivery Mechanisms and Efficient Technologies (CFL, LED).

• Go to the following sections in the Presentation tab in the proposed measure workbook:– Comparison-Savings– Comparison-Cost– Comparison-TRC BC

Page 31: Residential Lighting LED and CFL Lamps

31

RTF Staff Recommendation• Regional commitment to research the questions on Slide 5 in time for

measure update next year.• Group Three-Way with General Purpose and Dimmable. Three-way has

relatively small volume in RBSA, programs, and Energy Star and there may be cross-shopping between these lamp types.

• Approve LED and CFL lamp measures as presented– Using the proposed measure identification categories (3 room types, 5 4 lamp types,

3 lumen categories)– Allow data-gap filling for efficient lamp datasets

• Set the measure category to “Proven”• Set the measure status to “Active”• Set the sunset date to June 2015 (allows one year for new data plus two

months for Staff analysis).• Develop a Residential LED Fixtures measure set for presentation to the RTF in

summer 2014.

Page 32: Residential Lighting LED and CFL Lamps

32

Proposed Decision

“I _______________ move that the RTF:• Approve LED and CFL lamp measures as presented• Using the proposed measure identification categories

(3 room types, [5] or [4] lamp types, 3 lumen categories)

• Set the measure category to “Proven”• Set the measure status to “Active”• Set the sunset date to June 2015

Page 33: Residential Lighting LED and CFL Lamps

33

Appendix: Storage Rate Slides from October 2013 CFL Presentation

Page 34: Residential Lighting LED and CFL Lamps

34

Accounting for Storage Rate• To date, the RTF has not counted savings for energy efficient

equipment that is installed later on.• But there is evidence that most CFLs eventually get installed,

probably within a few years of purchase or receipt.• How should the RTF account for stored-but-eventually-used

products?

Page 35: Residential Lighting LED and CFL Lamps

35

Storage Rate – Lifetime Guidelines1.2.2. Measure Lifetime• Measure lifetime is defined as the median number of years during which at

least half the deliveries of a measure are in place and operable, i.e., produce savings. Measure lifetime should not be confused with a measure’s sunset date, which is the period during which a measure’s savings estimation method is RTF-approved.

2.3.1. Factors Affecting Lifetime• Many factors may have a substantial impact on measure lifetime. All

substantial factors should be considered in the estimation. A factor is substantial if it would increase or decrease the measure lifetime by at least 20%.

• Factors that may be relevant to measure lifetime include, but are not limited to, the following.– Program delivery method. Measures directly installed may last longer than measures

delivered via mail for self-install, because self-installers may be less skilled and may not install according to manufacturer expectations, such as appropriate placement.

Page 36: Residential Lighting LED and CFL Lamps

36

Storage Rate – CFL Failure

• Lamps installed right away (e.g., direct install)

Source: Review of Massachusetts tracking data. Lynn Hoefgen et al., 2013, “Study It ‘til You’re Sick of It: CFL Research as an Example of Other Efficiency Markets”, 2013 International Energy Program Evaluation Conference.

Page 37: Residential Lighting LED and CFL Lamps

37

Storage Rate – CFL Failure

• But not all retail lamps get installed right away

Assumes that 24% of lamps are installed at time of receipt, and 8% of lamps are installed in each of the subsequent 3 years.

Page 38: Residential Lighting LED and CFL Lamps

38

Storage Rate – CFL Failure

• But not all retail lamps get installed right awayNote:1) Installation rate

increases in first few years

2) But some lamps installed in the first couple of years are already failing

3) The lifetime of the retail measure (6.1) is longer than that of the direct install measure (5.5).

Page 39: Residential Lighting LED and CFL Lamps

39

Storage Rate – Savings GuidelinesRoadmap 1.3.2. Savings• “Savings is defined as the difference in energy

use between the baseline (see section 3.2) and post (after measure delivery) periods, which is caused by the delivery of a measure.”– Not clear on how to specify savings with unusual

decay functions.– Historically, RTF has used first year savings, except

for Last Measure In (LMI) measures.

Page 40: Residential Lighting LED and CFL Lamps

40

Storage Rate – Questions• What should the savings value represent?

– First year savings?– Maximum savings before end of EUL?– Average savings from measure start until death of last unit?– Something else?

• The answer to this should inform how to handle storage rates for CFLs, where we – know the patterns of failure overtime, and – think we know when stored bulbs eventually get used

• Staff proposal: – Use first year savings– Use failure and installation patterns to estimate median time to 50% installation. This complies with

the Guidelines.– Guidelines Issue: This does not lead to the correct lifetime savings (savings x EUL).

[RTF approved this proposal at the October 2013 RTF meeting]

• Staff also received a proposal to disregard storage rate because the stored lamps tend to get installed within a few years. This has been discussed at previous RTF meetings.