REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. -...

36
RFQ Document - Clifton Park Toilet Block Installation Page 1 of 14 REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK TOILET BLOCK INSTALLATION September 2018

Transcript of REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. -...

Page 1: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 1 of 14

REQUEST FOR QUOTATION DOCUMENT for

CLIFTON PARK TOILET BLOCK INSTALLATION

September 2018

Page 2: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 2 of 14

1. INTRODUCTION Council has received funding from the Australian Lions Foundation, Crookwell Lions Club, Gullen Range Windfarm, Stronger Communities Programme, and Veolia Mulwaree Trust for supply and installation of a new amenities building (toilet block) in Clifton Park, Crookwell.

The supply and delivery of the toilet block has already been awarded to Modus Australia and the pre-fabricated toilet building (in kit form) and associated fixtures are expected to be delivered at project site by 26 September 2018. Under the scope of this quotation, Council is seeking quotes from appropriately licensed Contractors to undertake the works identified in accordance with the scope of works.

Scope of Works

A summary of the works is as follows, but not limited to;

To be completed by Contractor:

• Installation of the new toilet block broadly includes: excavation for the concrete pad, completing concrete pad, installation of the toilet block elements, fitting all the fixtures within the building, reinstating the disturbed ground.

• Plumbing works from the internal toilet fixtures to the connection point for water and sewer line.

• Installation of the toilet block as per the attached installation guide and drawings.

• Standard landscaping on left and right part of the toilet building. In addition to that back side landscaping should be done with such bushes that compliment the landscape and hide the back view of the building from the residents’ house.

To be completed by Contractor:

• Survey and set out for the purpose of installation work.

• Sewer and water connection from toilet block to main sewer and water line.

• Supply of prefabricated toilet building to the project site.

• Dial before you dig investigations.

General Construction Notes

• All relevant documentation to be supplied by the contractor unless noted otherwise.

• All services are to be located safely by the contractor.

• A Traffic Control Plan will be required to allow safe vehicle access to the Clifton Park. Work shall not hamper use of any of the park facilities.

• Work will not hold up local vehicle access to the nearby McIntosh road for a period exceeding 5 minutes. If required, detours may be implemented to redirect traffic.

Page 3: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 3 of 14

• All work areas must have temporary safety fencing to prevent public access. Any areas where this is not possible will need to be made safe for public access/egress and warning/advisory signage erected.

• All work shall comply with applicable legislations.

• All building works are to be carried out by a suitably licenced person(s)

• All plumbing works are to be carried out by a suitably licenced person(s).

• All electrical works are to be carried out by a suitably licenced person(s).

• All work associated with this project is to be completed within 4 weeks from the date of contract award.

Work Program

• The successful company is to supply a work program in a GANTT Chart format outlining the key items and delivery time for each item, including handover date.

2. DOCUMENTATION The documentation to be supplied to Upper Lachlan Shire Council under this project comprises, but not limited to the following components;

• Prior to engagement; - Completed Price Schedule (attachment 1) - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details

• Prior to associated works commencing; - Dial Before You Dig report - Trades licence details - Safe Work Method Statements (SWMS) to be approved by Council - Traffic Control Plan (to allow access of vehicles to nearby roads) to be approved by Council

NOTE: All business and trades accreditations/licences must be relevant and in date. A “stop work order” may be implemented by Upper Lachlan Shire Council where documentation has not been provided prior to associated work commencing.

3. INSURANCES Insurances required for this engagement are Public Liability ($20m), Professional Indemnity ($5m) and Workers Compensation. Certificates of currency for these will be required from the successful contractor.

4. QUOTATIONS – CLOSING DATE AND TIME Quotations will be received up to 4.00pm on Monday 17th of September 2018. Quotations will be accepted by mail (PO Box 42, GUNNING NSW 2580) or email [email protected] . Email attachment should not be more than 10 MB

Page 4: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 4 of 14

5. ENQUIRIES Enquiries are to be emailed to Asif Faisal – Project Delivery Engineer [email protected] .

6. Attachments • Attachment 1 – Price Schedule • Attachment 2 – Location map and site photos • Attachment 3 – Approved Drawings • Attachment 4 – Contour and Layout Map • Attachment 5 – Assembly Instructions • Attachment 6 – Dial Before You Dig (DBYD) enquiry details

Page 5: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 5 of 14

Attachment 1 – Fee/Price Schedule

Page 6: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 6 of 14

Attachment 1

Please complete the following Pricing Schedule. This engagement will be for all inclusive hourly rates of staff, plant and equipment. Materials costs will be to supply all materials with a margin for handling and administration. Completed Price Schedule to be returned to Council by 17th September 2018.

Fee/Price Schedule

Project Resources (staff, plant, materials) Amount (incl. GST)

Excavation Concreting Toilet Block Installation and fitting all the fixtures as per drawings and Assembly Instructions

Completing internal plumbing works Reinstating disturbed ground with a 1:20 slope to match with existing ground and turf the compacted ground

Large bush Landscaping at street side (back side) of the toilet block

All other work and obligations NOT INCLUDED ELSEWHERE in this Schedule

All pricing shall remain fixed for the period of the engagement, is not subject to rise and fall and is inclusive of GST.

Company Name:

Contact Details:

Date:

Price Hold

Based on the contents of this RFQ advise the timeframe the nominated Price Schedule will remain valid following the closing date:

__________ days.

Page 7: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 7 of 14

Attachment 2 – Location Map and Site Photos

Page 8: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 8 of 14

Proposed Location for Clifton Park Toilet Block

Map Zoom = 0.4334 km Cadastral Information © Department of Lands NSW Digital Cadastral Database DCDB

Disclaimer Note Services shown on this public amenity land are not

public drains unless used as through drains. No Guarantee is given as to the accuracy and location of services. Verify all levels and locations on site. For any

enquiries about the services shown please phone

NOTE: The dimensions and scaling on this plan are approximate and may vary from the actual legal land size. This information is indicative and/or may not be up to date and should not be relied upon for purchase, development or any legal purpose. UPPER LACHLAN COUNCIL.

Created on Tuesday, 22 May 2018

Clifton Park Toilet Block (6m x 4m)

Water Lines --------- Sewer Lines ---------

Page 9: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 9 of 14

Page 10: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 10 of 14

Page 11: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 11 of 14

Attachment 3 – Approved Drawings

Page 12: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

B

C

A

43

D

BUILDING COMPLIES WITH AS1428.1DISABLED ACCESS STANDARDS

1 2

CONCRETE PAD TO BE FLAT;NO SLOPING AND TO BE

TROWELLED FINISH

200

3512

20C

LEA

R V

ERA

ND

AH

WID

TH24

06TO

TAL

BUIL

DIN

G W

IDTH

115

115 5910TOTAL BUILDING LENGTH

115

1168

TYP

1098

TYP

1168TYP

1098TYP

100 X 100 X 3VERANDAH POST

70 X 70 X 3COLUMN

1400CIRCULATION SPACE

LINE OF ROOF

794 700 380 420 42

80 910DOOR OPENING

500 926

1490CIRCULATION SPACE

514

50C

IRC

ULA

TION

SPA

CE

5445

850

1403

915

735CLEAR

910CLEAR

211

199

5 6

42 2296

910DOOR OPENING

1426 910DOOR OPENING

279

2298

1:FLOOR PLANA

01a

-

40 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

01a

-

FLOOR PLAN

WAYNE
NER
Page 13: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

B

C

A

43

D

6896OVERALL ROOF LENGTH

4287

OV

ERA

LL R

OO

F W

IDTH

BUILDING COMPLIES WITH AS1428.1DISABLED ACCESS STANDARDS

21

76 X 38 X 1.6 RHS

LINE OF ROOF

75 X 50 X 2 RHS 76 X 38 X 1.6 ERWBRIDGING PURLIN

5 6

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

01

ROOF PLAN

FLOOR PLAN

1:ROOF PLANB

01

-

40 M.

WAYNE
NER
Page 14: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

43

2852

OV

ERA

LL S

TRUC

TURE

HEI

GHT

2235

617

21

5910OVERALL STRUCTURE LENGTH

75 X 75 x 3 SHS COLUMNS

ALUMINIUM 'T' BOARD

75 X 50 X 2 RHS

76 X 38 X 1.6 RHS

0.48 BMT COLORBONDCORRUGATED ROOFING FIXEDWITH 12 X 35 TEK SCREWS

0.42 BMT COLORBONDCORRUGATED FIXED WITH 10 X 16TEK SCREWS

DOOR SIGNS COMPLIANT WITHAS1428.1 (2009)

5 6

43

01B

300 5540 300

6140TOTAL SLAB LENGTH

300

200

100

21

DOOR OPENINGDOOR OPENING

30 X 30 X 2 SHSFULLY WELDED FRAME

THESE LINES DENOTENUTSERTS AND BOLTS

75 X 50 X 2 RHS

76 X 38 X 1.6 RHS

0.48 BMT COLORBONDCORRUGATED ROOFING FIXEDWITH 12 X 35 TEK SCREWS

300 X 300 FOOTINGALL AROUND

70 x 70 x 3 CHANNEL

5 6

DOOR OPENING

1:FRONT ELEVATION WITH CLADDINGA

02

-

40 M.

1:FRONT ELEVATION WITHOUT CLADDINGB

02

-

40 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

02a

-

FRONT ELEVATIONS

WAYNE
NER
Page 15: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

A B C D

2275

1300

975

2862

OV

ERA

LL S

TRUC

TURE

HEI

GHT

2426OVERALL STRUCTURE WIDTH

0.48 BMT COLORBOND CORRUGATEDROOFING FIXED WITH 12 X 35 TEK SCREWS

70 X 70 X 3 CHANNELS

ALUMINIUM 'T' BOARD

0.42 BMT COLORBONDCORRUGATED FIXED WITH10 X 16 TEK SCREWS

75 X 75 x 3 SHS COLUMNS

A B C D

04C

04B

04A

04E

04D

300 2036 300 940

400

FOO

TING

DEP

TH

3976TOTAL SLAB WIDTH

400FOOTING Ø

300

200

100

7°7°

0.48 BMT COLORBOND CORRUGATEDROOFING FIXED WITH 12 X 35 TEK SCREWS

75 X 50 X 2 RHS

76 X 38 X 1.6 RHS

70 x 70 x 3 CHANNELS

30 X 30 X 2 SHSFULLY WELDED FRAME

THESE LINES DENOTENUTSERTS AND BOLTS

400Ø x 400 DEEPFOOTING

1:SIDE ELEVATION WITH CLADDINGA

03

-

40 M.

1:SIDE ELEVATION WITHOUT CLADDINGB

03

-

40 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

02b

-

SIDE ELEVATIONS

1 in 20

Top of Slab RL = 905.710

WAYNE
NER
lachlanmc
Line
lachlanmc
Callout
Existing Natural Surface
lachlanmc
Line
lachlanmc
Callout
1 in 20 slope leading from surrounding natural surface up to toilet block.
lachlanmc
Line
Page 16: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

70 X 70 X 3CHANNEL

M10 X 110 THREADCHEMI-ANCHOREDINTO CONCRETE

70 X 70 X 5 PLATE

M10 BOLT

30 X 30 FRAME

70 x 70 x 3 CHANNEL

70 x 70 x 5 PLATE

M10 BOLT

0.6 ZINCALUME MINIFLUTECLADDING FIXED WITH12 X 35 TEK SCREWS WITH4-3 MONEL RIVETS

0.42 BMT COLORBOND CORRUGATEDFIXED WITH 10 X 16 TEK SCREWS AND205mm X 7.5mm DURAPLANKRUSTICATED WOODGRAIN

0.48 BMT COLORBOND CORRUGATEDFIXED WITH 14 X 45 TEKSCREWS AND CYCLONIC WASHERS

125 X 125 TIMBERVERANDAH POST

M10 BOLT

75 X 50 X 2 RHS

76 X 38 X 1.6 RHS

735CLEAR

216

1070

910CLEAR

ANGLE SUPPORT 35 X 2000mm

TOP Z-TRIM 216 X 2000mm(FITTED LAST)

INTERNAL Z-TRIM208 X 2000mm

MINI ORB SHEETS

ANGLE SUPPORT 35 X 2000mm(FIT BEFORE MINIORB)

FRONT Z-TRIM215 X 2000mm

COLUMN MOUNTINGA

DIMENSIONS

SPECIFICATION SHEET FOR YARRA UA TOILET BUILDING

Structure complies with Region A, TC2, V500 = 41 m/sAS PER AS1170.2

MATERIALS

FOOTINGS

WIDTHLENGTH

ROOF SLOPEHEIGHT

--

--

2400 mm5910 mm

7° 3000 mm

RAFTERS - 75 X 50 X 2 RHS

FRAME TO COLUMNB PURLIN TO COLUMN DETC

PANEL MOUNTINGD VERANDAH FIXING DETAILE

PURLINS - 76 X 38 X 1.6 RHS

VERANDAH COLUMNS - 75 X 75 X 5 SHS

OUTSIDE CLADDING - 0.42 BMT COLORBOND CORRUGATEDFIXED WITH 10 X 16 TEK SCREWS ANDALUMINIUM 'T' BOARD

INSIDE CLADDING - 0.6 ZINCALUME MINIFLUTE CLADDINGFIXED WITH 4-3 MONEL RIVETS-

ROOF CLADDING - 0.48 BMT COLORBOND CORRUGATEDFIXED WITH 12 X 35 TEK SCREWS-

HOLDING DOWN FIXINGS - M10 X 110 THREADED ROD CHEMICALANCHORED INTO CONCRETE.

FRAMING BOLTS - M10 X 30 S/S BOLTSDOOR - READY COAT TIMBER DOOR CLAD IN

0.55 COLORBOND ON OUTSIDE AND0.55 ZINCALUME ON THE INSIDE

LATTICE - 0.8mm GALVABOND POWDERCOATED

FLASHINGS & TRIMS - 0.55 COLORBOND

COLUMNS - 70 X 70 X 3 CHANNEL

-

TO CHOICE OF COLOUR

CONCRETE N25 WITH SL72 REINFORCING MESH WITH 40mm TOPCOVER, ON 0.2 PVC ON GROUND COMPACTED TO (7 BLOWS /300mm²).

CONCRETE SLAB 100mm THICK AND TYPICAL EDGE 300mm THICK BY300mm DEEP. FOOTINGS FOR EACH VERANDAH COLUMN ARE400mm X 400mm X 400mm.

REFER TO TABLE BELOW FOR FOOTING REO SCHEDULE.

FRAMES - 30 X 30 X 2.5 SHS

SOIL CLASS

A

S

M

H1

FOOTING DEPTH

300

300

FOOTING REO

3-L8TM

3-L11TM BEAMS @ 4000 c/c

H2 400 BEAMS @ 4000 c/c

300

300

3-L8TM

3-L8TM

3-L11TM

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

03

SPECIFICATIONS

DETAILS AND

AMBULANT DETAILF

WAYNE
NER
Page 17: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

B

C

A

43

D

BUILDING COMPLIES WITH AS1428.1DISABLED ACCESS STANDARDS

1 2

CONCRETE PAD TO BE FLAT;NO SLOPING AND TO BE

TROWELLED FINISH

BACK OF SLAB 12mm SUPPLY

100mm SEWER

THICKENING UNDERWALLS 300mm DEEP X

300mm WIDE

100mm CONCRETE SLAB

FLOOR DRAIN

40mm BASIN DRAINAND 12mm SUPPLY

3976

TOTA

L SL

AB

WID

TH

6140TOTAL SLAB LENGTH

200

200

940

150

1168

1168

150

150 11681168 1168 150

219 100 699 1168 373

1018 1088 80 471 617

186

150

150

400

940

150

150

346

50

150

100

300

250 15023

0

98

FLOOR DRAIN

12mm SUPPLY

100mm SEWER

300

150 150

150 250 2470

1018

832

400 2470

5 6

697 1168 1018 150 150

80 1168 1018 300

1:CONCRETE PAD LAYOUTA

05

-

30 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLED ACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITH AS1428.1:2009

AMBULANT TOILET COMPLIES WITH AS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPING AND TO BE TROWELLED FINISH

TOP OF SLAB RL TO BE 905.710

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

04

-

CONCRETE LAYOUT

Top of Slab RL = 905.710

WAYNE
NER
lachlanmc
Callout
Easting = 727167.100 Northing = 6185308.330
lachlanmc
Callout
Easting = 727166.409 Northing = 6185304.415
lachlanmc
Callout
Easting = 727160.362 Northing = 6185305.481
lachlanmc
Callout
Easting = 727161.053 Northing = 6185309.396
Page 18: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

B

C

A

43

D

BUILDING COMPLIES WITH AS1428.1DISABLED ACCESS STANDARDS

1 2

CONCRETE PAD TO BE FLAT;NO SLOPING AND TO BE

TROWELLED FINISH

BACK OF SLAB 12mm SUPPLY

100mm SEWER

100mm CONCRETE SLAB

FLOOR DRAIN

40mm BASIN DRAINAND 12mm SUPPLY

1318 1088 551 617

1590

868

972

230

230

486

100 2238 100

116

2566

200

FLOOR DRAIN

12mm SUPPLY

100mm SEWER

519

5 6

3183

1:PLUMBING PRELAY PLANA

05

-

30 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

05

-

PLUMBING PRELAY

WAYNE
NER
Page 19: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

640

DIS

PEN

SER

HEIG

HT

1400

DIS

ABL

ED B

AR

HEIG

HT

450 272 320

640

DIS

PEN

SER

HEIG

HT

1400

DIS

ABL

ED B

AR

HEIG

HT

575

275

800

GRA

B BA

R HE

IGHT

800

107 800

331714

TOILET PAPER DISPENSERMOUNTING AREA

750

450

815

BASI

N A

ND

SHE

LF H

EIG

HT

850

TOP

OF

BAC

KRES

T

850

TOP

OF

BAC

KRES

T

BABY CHANGE STATION

470

UNIVERSAL TOILET COMPLIES WITH AS1428.1:2009 UNIVERSAL TOILET COMPLIES WITH AS1428.1:2009 UNIVERSAL TOILET COMPLIES WITH AS1428.1:2009

840

BASI

N A

ND

SHE

LF H

EIG

HT

420

DISABLED CODECLEAR ACCESS

720

440

200

300

1400

CO

AT

HOO

K HE

IGHT

500

640

DIS

PEN

SER

HEIG

HT1220

DIS

ABL

ED B

AR

HEIG

HT

820

680450

820

35

648

1220

DIS

ABL

ED B

AR

HEIG

HT

835

800

450 95 610

640

DIS

PEN

SER

HEIG

HT1220

DIS

ABL

ED B

AR

HEIG

HT

835

800

TOILET PAPER DISPENSERMOUNTING AREA

735

910CLEAR

AMBULANT TOILET COMPLIES WITH AS1428.1:2009 AMBULANT TOILET COMPLIES WITH AS1428.1:2009 AMBULANT TOILET COMPLIES WITH AS1428.1:2009

2000

2000

1400

CO

AT

HOO

K HE

IGHT

500

UNIVERSAL MOUNTING DETAIL AA UNIVERSAL MOUNTING DETAIL BB UNIVERSAL MOUNTING DETAIL CC

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

06

-

MOUNTING DETAILS

AMBULANT MOUNTING DETAIL AD AMBULANT MOUNTING DETAIL BE AMBULANT MOUNTING DETAIL CF

WAYNE
NER
Page 20: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

B

C

A

43

D

BUILDING COMPLIES WITH AS1428.1DISABLED ACCESS STANDARDS

1 2

CONCRETE PAD TO BE FLAT;NO SLOPING AND TO BE

TROWELLED FINISH

2

1

3

7 8

6 9

105

4

5 6

11 13

14

15

12

1:PANEL LAYOUTA

07

-

40 M.

Contractor to set out and take sitedimensions. SCALE FROM THIS DRAWING

FOR PLANNING PURPOSES ONLY.

TITLE

DATE

DRAWN

CHECKED

SHEET NO.REV NO.

PROJECT NAME

CLIENT

NOTES

JOB NO.

OF

07

REVISIONS DATE

-

5965

MODUS AUSTRALIALEVEL 27, 32 TURBOT STREET

BRISBANE QLD 4000

PH: 1300 945 930e: [email protected]

DISCLAIMER © COPYRIGHT MODUS AUSTRALIA.This drawing and design must not be copied inwhole or in part without the written consent ofMODUS AUSTRALIA unless it is used to aid in thespecification and/or procurement of MODUS

AUSTRALIA products.

UPPER LACHLANSHIRE COUNCIL

CONTACT: -PH: -

FAX: -e: -

CLIFTON PARKYARRA UASto

APPROVED BY

(Not valid unless signed by Certified Structural Engineer)

SC

ASH

16/08/2018

BUILDING COMPLIES WITH AS1428.1 DISABLEDACCESS STANDARDS

UNIVERSAL TOILET COMPLIES WITHAS1428.1:2009

AMBULANT TOILET COMPLIES WITHAS1428.1:2009

CONCRETE PAD TO BE FLAT; NO SLOPINGAND TO BE TROWELLED FINISH

Structure complies with:Region A, TC2, V500 = 41 m/s AS PER AS1170.2.

-

-

-

-

-

-

-

-

07

-

PANEL LAYOUT

WAYNE
NER
Page 21: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 12 of 14

Attachment 4 - Contour and Layout Map

Page 22: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

1 in 20 Slope up to Toilet Block

1 in

20

Slop

e up

to T

oile

t Blo

c k 1 in 20 Slope up to Toilet Block

1 in 20 Slope up to Toilet Block

Toilet Block

0 1 1

A

B

C

1 2 3

D

E

F

G

1 2 3 4 5 6 7 8 9 10 11 12

H

4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

REVISIONS DATE

SCALE

HORIZONTAL

PLAN No. No of SHEETSSHEET No.

FORMATION WIDTH:

PAVEMENT DEPTH:

Date A3

SEALING WIDTH:

MAY HAVE A REDUCED SCALE FACTOR

ORIGINAL ISSUEA

VERTICAL

LANE WIDTH:

14/11/11

CIVILCAD FILE: C:\Users\lachlanmc.ULSC\Desktop\Clifton Park Toilet Block.mjo - Drawing001

H

SHEETSIZE

SURVEYED:

ORIGIN OF LEVELS

DATUM

DESIGNED

DRAWN

CHECKED

DRAWING FILE:

CIVILCAD FILE:TITLE BLK:

ALIGNMENT LAYER:

Sheet Number: 1 Total Sheets: 1

UPPER LACHLAN SHIRE COUNCILAPPROVED

Director of Works& Operations

1:35

1Clifton Park Toilet Block - Drawing001A3 Titleblock ULSC DRAFT

Page 23: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 13 of 14

Attachment 5 – Assembly Instructions

Please note the following assembly instructions will be superseded by the detailed assembly instructions which will be provided at the delivery of the

toilet block to Council.

Page 24: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

MODUS AUSTRALIA

Assembly InstructionsModus Australia Toilet Building

Page 25: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

YARRA 3 Assembly Instructions

STEP II• Starting at panels 1 & 2 put the two wall sections together using the

appropri-ate joining channel & bolts provided. • Then place corner angle over corner thread & align walls with lines on

concrete.• Wind nut & washer onto thread inside base of corner angle. Don’t fully

tighten.• Place all wall panels in the sequence as shown using the numbers on

panels matching up to the numbers shown on the panel layout drawing.

STEP I• Mark out wall centerlines on concrete pad in according to plan supplied.• Mark fixing point centre’s & drill 12mm diameter holes to 100mm deep.• Remove dust from holes as shown on chemical anchor tube.• Place a thread beside each hole.• Apply chemical anchor into holes & place 10mm s/s threaded rod (125mm

long) with 100mm into concrete & 25mm above.

Please note: work with one hole at a time as chemical anchor sets quite quickly.

STEP III• Continue placing wall panels & joining channels and fixing nut & washes

to threads.• Place all wall panels in the sequence as shown using the numbers on

panels matching up to the numbers shown on the panel layout drawing.

Copyright:© This document is covered by Copyright act. No part of this correspondence should be reproduced,adapted or disseminated without the prior written consent from the proprietors of Modus Australiaor it connected entities. Neither shall any part of this document be reprinted or handled in anywaycontrary to the wishes of the author whether in part or in whole, in any form or by any means

1 2

1 23 4

56

Page 26: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

YARRA 3 Assembly Instructions

Copyright:© This document is covered by Copyright act. No part of this correspondence should be reproduced,adapted or disseminated without the prior written consent from the proprietors of Modus Australiaor it connected entities. Neither shall any part of this document be reprinted or handled in anywaycontrary to the wishes of the author whether in part or in whole, in any form or by any means

STEP VI• Continue placing wall panels & joining channels and fixing nut & washes

to threads.• Place all wall panels in the sequence as shown using the numbers on

panels matching up to the numbers shown on the panel layout drawing.

STEP V• Continue placing wall panels & joining channels and fixing nut & washers

to threads.• Place all wall panels in the sequence as shown using the numbers on

panels matching up to the numbers shown on the panel layout drawing.

STEP IV• Continue placing wall panels & joining channels and fixing nut

& washes to threads.• Place all wall panels in the sequence as shown using the

numbers on panels matching up to the numbers shown on the panel layout drawing.

1 23 4

56

7

1 23 4

56

78

101314

1516

1112

9

1 23 4

56

78

10

1112

9

8

Page 27: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

YARRA 3 Assembly Instructions

Copyright:© This document is covered by Copyright act. No part of this correspondence should be reproduced,adapted or disseminated without the prior written consent from the proprietors of Modus Australiaor it connected entities. Neither shall any part of this document be reprinted or handled in anywaycontrary to the wishes of the author whether in part or in whole, in any form or by any means

STEP IX• Drill and fasten verandah columns

STEP VIII• Bolt fascia purlin to barge boards. • Connect columns to fascia purlin.• Columns to lean forward on a 7 degree angle.

STEP VII• Place 3 purlins over joining channels & apply bolts in locations

provided. Don’t fully tighten. • Bolt barge boards to purlins in locations provided.• All bolts can now be fully tightened.

Page 28: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

YARRA 3 Assembly Instructions

Copyright:© This document is covered by Copyright act. No part of this correspondence should be reproduced,adapted or disseminated without the prior written consent from the proprietors of Modus Australiaor it connected entities. Neither shall any part of this document be reprinted or handled in anywaycontrary to the wishes of the author whether in part or in whole, in any form or by any means

STEP XII• Building is now complete!

STEP XI• Fit wall & roof trims.

STEP X• Sheet roof with Colorbond material provided.

Page 29: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;
Page 30: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RFQ Document - Clifton Park Toilet Block Installation Page 14 of 14

Attachment 6 – Dial Before You Dig (DBYD) enquiry details

Page 31: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

Phone: 1100www.1100.com.au

Dig Site and Enquiry Details

Caller Details

Asset Owner Details

WARNING: The map below only displays the location of the proposed dig site and does not display any asset owners' pipe or cables. The area highlighted has been used only to identify the participating asset owners, who will send information to you directly.

● Check the location of the dig site is correct. If not submit a new enquiry.● If the scope of works change, or plan validity dates expire, resubmit your enquiry.● Do NOT dig without plans. Safe excavation is your responsibility. If you do not understand the plans or how to proceed safely, please contact the relevant asset owners.

Your Responsibilities and Duty of Care● If plans are not received within 2 working days, contact the asset owners directly & quote their Sequence No.● ALWAYS perform an onsite inspection for the presence of assets. Should you require an onsite location, contact the asset owners directly. Please remember, plans do not detail the exact location of assets.● Pothole to establish the exact location of all underground assets using a hand shovel, before using heavy machinery.● Ensure you adhere to any State legislative requirements regarding Duty of Care and safe digging requirements.● If you damage an underground asset you MUST advise the asset owner immediately.● By using this service, you agree to Privacy Policy and the terms and disclaimers set out at www.1100.com.au● For more information on safe excavation practices, visit www.1100.com.au

The assets owners listed below have been requested to contact you with information about their asset locations within 2 working days.Additional time should be allowed for information issued by post. It is your responsibility to identify the presence of any underground assets in and around your proposed dig site. Please be aware, that not all asset owners are registered with the Dial Before You Dig service, so it is your responsibility to identify and contact any asset owners not listed here directly.** Asset owners highlighted by asterisks ** require that you visit their offices to collect plans.# Asset owners highlighted with a hash require that you call them to discuss your enquiry or to obtain plans.

Contact:

Company: Mobile: Fax:

Email:

Caller Id:

Address:

Job Purpose:

Enquiry Date:

Working on Behalf of:Start Date:

Onsite Activity:

Location in Road:

Phone:

End Date:

Address:

Location of Workplace:

Notes/Description of Works:

User Reference: Clifton Park Toilet

Job No 14528308

1272353

Crookwell NSW 2583

30/09/2018

Not Supplied

Upper Lachlan Shire Council

Not Supplied

PO BOX 144 Goulburn rd

Planning & Design

Crookwell NSW 2583

10/07/2018

CarriageWay,Footpath,Nature Strip

06/07/2018

Goulburn Street

[email protected]

Both

0248320425

Upper Lachlan Shire Council 0498241266

Mr Robert Johnson

Design

Seq. No. Authority Name Phone Status73208230 Essential Energy 132391 NOTIFIED73208234 NBN Co, NswAct 1800626762 NOTIFIED73208232 Telstra NSW, South 1800653935 NOTIFIED

END OF UTILITIES LIST

Page 32: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;
Page 33: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

Indicative Plans

Issue Date: 06/07/2018

Location: Goulburn Street,Crookwell,NSW-2583

Page 34: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

Emergency ContactsYou must immediately report any damage to nbn™ network that you are/become aware of.Notification may be by telephone - 1800 626 329.

Page 35: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RIC

HA

RD

SO

NST

SA

LE

YA

RD

S

RE

DG

RO

UN

D

CL

IFT

ON

ST

86

10

18

5

16

6

89

93

91

85 8314

26

5

22

34

97

95

101

99

LBD

P387847

L1

DP1112816

EJ

20.0

58.5

OC

[ 6m

m]

2

5

P50OC[13mm]P505

OC[ 4mm]5

OC[10mm] 5

OC[ 4mm]

30.1

P20OC[ 6

mm

]

P35 OC[13mm]

5.0

10LEFT IN SITU

10/0.51

58.5

OC[ 6mm]

OC[ 6mm]

P35

OC[ 6mm]

82.0

OC

[10m

m]

21.4

OC

[13m

m]

OC

[ 4m

m]

P10

B 51.0

5

2OC[ 6mm]

OC[16mm]

OC[10mm]

OC[ 4mm]

OC[12mm]OC[14mm]OC[16mm] OC

[ 6m

m]

P35

MC 5

20.1

34.7

MC MC

5OC[12mm]OC[14mm]OC[16mm]

OC[14mm]P50 25.5

P35

2xOC[16mm]OC[29mm]

3.0

MC

52.4

OC[12mm]OC[14mm]OC[16mm]

3 35.4

P100

OC[14mm]6.1

5

54P50

P50

21.0

AF

43.4

OC[10mm]

OC

[ 4m

m]

5

22.0

P100

OC[ 6mm]

OC

[24m

m]

2xO

C[1

2mm

]50

/0.9

0

OC[ 6mm]

3

P50

O43

1-48

0

145.

3

O431-480

18.3

OC[ 4mm]

P10

0

11.3OC[ 4mm]

36.6

370

.7

OC

[10m

m]

P50

A100OC[10mm]OC[16mm]

OC

[12m

m]

OC

[23m

m]

5

OC

[23m

m]5

P50

40.0

OC[10mm]

OC[12mm]OC[14mm]OC[16mm]

OC[12mm]OC[14mm]OC[16mm]

OC

[ 6m

m]

OC[16mm]3

22.3

OC

[ 6m

m]

OC

[ 6m

m]

34.7

MC

57

OC[12mm]OC[14mm]OC[16mm]

OC

[ 6m

m]OC[ 4mm]

2

34.7

50/0.90OC[16mm]P1:O431-480

A100 190.7

OC[ 6mm]

OC

[12m

m]

OC

[23m

m]

OC[ 6mm]25

15.1OC[10mm]OC[23mm]

P35

54.8P35

26.8

2

27.8

P35 O

C[ 6

mm

]

OC

[12m

m]

OC

[23m

m]

OC[12mm]

OC[23mm]

OC[ 6mm]

28.9

8

OC[ 6mm]

54

P35 3.5OC[12mm]

OC[23mm]

77.2

6

8

P11377m

TELSTRA CORPORATION LIMITED A.C.N. 051 775 556

For all Telstra DBYD plan enquiries - email - [email protected] urgent onsite contact only - ph 1800 653 935 (bus hrs)

Generated On 06/07/2018 16:34:16

N

S

W E

Cable Plan

0m 10m 20m 30m 40m 50m 60m

Sequence Number: 73208232

WARNING - Due to the nature of Telstra underground plant and the age of some cables and records, it is impossible to ascertain the precise location of all Telstra plant from Telstra's plans. The accuracy and/or completeness of the information supplied can not be guaranteed as property boundaries, depths and other natural landscape features may change over time, and accordingly the plans are indicative only. Telstra does not warrant or hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans.

It is your responsibility to locate Telstra's underground plant by careful hand pot-holing prior to any excavation in the vicinity and to exercise due care during that excavation.

Please read and understand the information supplied in the duty of care statement attached with the Telstra plans. TELSTRA WILL SEEK COMPENSATION FOR LOSS CAUSED BY DAMAGE TO ITS PLANT.

Telstra plans and information supplied are valid for 60 days from the date of issue. If this timeframe has elapsed, please reapply for plans.

CAUTION: Fibre optic and/ or major network presentin plot area. Please read the Duty of Care andcontact Telstra Plan Services should you requireany assistance.

The above plan must be viewed in conjunction with the Mains Cable Plan on the following page

Page 1 of 2

Page 36: REQUEST FOR QUOTATION DOCUMENT for CLIFTON PARK … · - Insurance details as per section 3. - Business ABN - Company/Contractor Licence details • Prior to associated works commencing;

RIC

HA

RD

SO

NST

SA

LE

YA

RD

S

RE

DG

RO

UN

D

CL

IFT

ON

ST

J2:J1-38 1406m CAC 2

103:AF-AE/1-6 6F/- SMOF FNFRHJ <- (AA)OC[16mm] (AA)DIST (AA)

3xOC(AA)3xOC(AA)

3xOC(AA)

5P35

P35

34.7

6

20.15

AF

3xOC(AA)

52.4

0.9---3.7

3234.3

35.4

0.9---1.8

5

35.7

89.0

1.2---4.3

71.0

J2:J1-38 50 PIQL AUA (AA) 12DEAD 103:AA-AF/1-6 6F/- SMOF FNPEHJ (AA) c4:M1-100 100/0.64 PIUT MB (BA) c4:M101-200 100/0.40 PIUT PE (BA)91

.1

103:AF-B2/1-12 12F/- SMOF FNPEHJ/STD (AA)OC[16mm] (AA)

3xOC(AA)

3xOC(AA)117.0

5

J2:J1-38 50 PIQL AUA (AA) 12DEAD 103:AA-AF/1-6 6F/- SMOF FNPEHJ (AA) c4:M1-100 100/0.64 PIUT MB (BA) c4:M101-200 100/0.40 PIUT PE (BA)

c103:AF-B2/1-12 12F/- SMOF FNPEHJ/STD (AA)

3P35

22.334.7

5

P50

P35 34.7P35

2

0.5---

3.4

P1 200/1800c4:M1-2001377mDA1

AA BA

A100

AA BA

A100

AA BA

A100

AA

P99

TELSTRA CORPORATION LIMITED A.C.N. 051 775 556

For all Telstra DBYD plan enquiries - email - [email protected] urgent onsite contact only - ph 1800 653 935 (bus hrs)

Generated On 06/07/2018 16:34:17

N

S

W E

Mains Cable Plan

0m 10m 20m 30m 40m 50m 60m

Sequence Number: 73208232

WARNING - Due to the nature of Telstra underground plant and the age of some cables and records, it is impossible to ascertain the precise location of all Telstra plant from Telstra's plans. The accuracy and/or completeness of the information supplied can not be guaranteed as property boundaries, depths and other natural landscape features may change over time, and accordingly the plans are indicative only. Telstra does not warrant or hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans.

It is your responsibility to locate Telstra's underground plant by careful hand pot-holing prior to any excavation in the vicinity and to exercise due care during that excavation.

Please read and understand the information supplied in the duty of care statement attached with the Telstra plans. TELSTRA WILL SEEK COMPENSATION FOR LOSS CAUSED BY DAMAGE TO ITS PLANT.

Telstra plans and information supplied are valid for 60 days from the date of issue. If this timeframe has elapsed, please reapply for plans.

CAUTION: Fibre optic and/ or major network presentin plot area. Please read the Duty of Care andcontact Telstra Plan Services should you requireany assistance.

Page 2 of 2