Report for CADSTAR Design 13_0 Incremental Patch2

5

Click here to load reader

description

Report for CADSTAR Design 13_0 Incremental Patch22

Transcript of Report for CADSTAR Design 13_0 Incremental Patch2

Page 1: Report for CADSTAR Design 13_0 Incremental Patch2

Patch Report for CADSTAR 13.0 Incremental Patch 2

*******************************************************************************

* Patch Release Report *

* NOTE This patch will only patch *

* CADSTAR 13.0 Patch 1 *

*******************************************************************************

Patch Release Name: Patch 2

Product Affected: CADSTAR 13.0

General Note:

This release announces itself as CADSTAR 13.0, Patch 2 in the Help, About

CADSTAR dialog.

This patch is only intended for installation into CADSTAR 13.0 Patch 1.

Defect Description Key:

Zuken Number(s)

Program

Area of Functionality

Brief Description of Defect

*******************************************************************************

Defects fixed since CADSTAR 13.0 Patch 1

CS-13099

Page 2: Report for CADSTAR Design 13_0 Incremental Patch2

PCB Design

EXPORT_RIF

If the final drill diameter (drill diameter plus Drill Oversize value) of a

pad/via exceeds the pad/via size, then a circular shape of the final drill

diameter is used to represent the pad/via in PREditor. For non-circular

pads/vias, this causes the wrong clearance shape to be used during copper pour.

CS-14396

CS-14397

PCB Design

EMBEDDED

In Embedded Router it is possible to select connections that have been set as

invisible in Design Editor.

CS-14418

PCB Design

EXPORT_RIF

When a component has a placement shape for top electrical layer and bottom

electrical layer, both the placement shapes are passed to the router on the

same layer (top electrical).

CS-14583

PCB Design

EXPORT_RIF

If a lengthening pattern contains curved segments, then constraints may not be

met when designs are transferred from Design Editor to PREditor XR HS.

CS-14664

Page 3: Report for CADSTAR Design 13_0 Incremental Patch2

Constraint Manager

VARIANTS

If a bus is deleted in Constraint Manager and the constituent nets are viewed

in the Electrical Nets section of the tree view, the logical nets may not be

visible.

CS-14702

Constraint Manager

ATTRIBUTES

Invalid warnings may be displayed when a design containing Net Classes is

opened in PREditor XR HS:

"There is already a Net at <pathname>

Duplicates will not be displayed in Constraint Manager"

CS-14703

Constraint Manager

CONSTRAINT_MANAGER

If a Differential Pair is deleted in Constraint Manager and the constituent

nets are viewed in the Electrical Nets section of the tree view, the logical

nets may not be visible.

CS-14705

PCB Design

IMPORT

Design Editor will crash when importing a CADIF file if the file was generated

with the option 'Output full CADSTAR names to CADIF' selected and Pad Code

names exceed 18 characters.

Page 4: Report for CADSTAR Design 13_0 Incremental Patch2

CS-14709

Constraint Manager

CONSTRAINT_MANAGER

Invalid warnings may be displayed when a design containing Skew Groups is

opened in PREditor XR HS:

"Error in CMDsgItem_RemoveNodePair: NULL this argument"

and

"CMguiError within attr/con synchronisation - Failed to upgrade pin <PinName>

attribute pin_length_grp (CMD error: 2)"

CS-14727

SCM Design

VARIANTS

In CADSTAR installations where the SCM Variant Manager authorisation is only

available on a network license, there may be performance problems when using

the schematic Design Editor.

CS-14748

PCB Design

EXPORT_RIF

Vias (and pads which have the same Pad Code name as vias) do not retain their

teardrop definitions when transferred to PREditor XR, causing teardrops to be

lost when the route is modified.

Page 5: Report for CADSTAR Design 13_0 Incremental Patch2

CS-14766

PCB Design

EXPORT_RIF

When Net Class values are deleted in Design Editor in Non-Legacy mode, the nets

are not removed from the Net Class tree in Constraint Manager.

CS-14837

PCB Design

DIMENSION_CHECK

In rare circumstances, Design Editor may fail to output a DRC spacing violation

and only output a Route Offsetting error.

*******************************************************************************

CADSTAR 13.0 patch 2 **WILL NOT** patch any release prior to CADSTAR 13.0

Patch 1.

This is an incremental patch, 07 September 2012