RENOVATIONS AND TENANT IMPROVEMENTS FOR … 9...gfrg grvl gyp gyp bd hb hd hdcp hdwr hm horz hr hvac...
Transcript of RENOVATIONS AND TENANT IMPROVEMENTS FOR … 9...gfrg grvl gyp gyp bd hb hd hdcp hdwr hm horz hr hvac...
REF.
D W D W
DW
DWG #
SHEET #
DWG #
SHEET #
DWG #
SHEET #
DWG #
SHEET #
DWG #
DW
G #
DW
G #
DWG #
SHEET #
DWG #
SHEET #
DWG #
SHEET #
1
A
W1
D1
G1
1-A
Level 10' - 0"
ROOM NAME
101
1
ENLARGED DETAIL INDICATOR
ELEVATION INDICATOREXTERIOR BUILDING ELEVATION
ELEVATION INDICATORSECONDARY ELEVATIONS;INTERIOR CABINETRY, ETC.
ELEVATION INDICATORSECONDARY ELEVATIONS;INTERIOR CABINETRY, ETC.
DETAIL SECTION
WALL SECTION
BUILDING SECTION
GRID LINES;VERTICAL GRIDS = #,HORIZONTAL GRIDS = LETTER
WINDOW TYPE
RESIDENTIAL DOOR TYPE
GLAZING TYPE
WALL TAG
ELEVATION MARKER
ROOM NAMEAND NUMBER
REVISION SYMBOL
NORTH ARROW
REVISION CLOUD
REQUIREDFIRE RATING
WALL TYPE
PROVIDE SOUND INSULATIONFIRE RATING OF WALL IN HOURS
N
FIRE RATING LEGEND (SEE WALL TYPES FOR U.L. LISTINGS)
ONE HOUR WALL
TWO HOUR WALL
THREE HOUR WALL
101A COMMERCIAL DOOR TYPE
A.A/CACOUSACPSACTADAADJAFFALTALUMAPPROXARCHAVWAWCAWCT
BETWBLDGB.O.B.O.S.BRKBRNGB.U.R.
CABCGCHCJCLCLGCLOSCMUCOCONCCONSTRCONTCPTCTCU
DFDIMDN.DWGDWR
EAEDFEIFSEJELECE.O.F.E.O.S.EQEQUIPEWCEXISTEXPEXT
FDFEFECFFFHCF.O.S.FJFRFRPFTFTGFVFWC
GAGALVGBGFIGFRCGFRGGRVLGYPGYP BD
HBHDHDCPHDWRHMHORZHRHVAC
INTINSUL
JANJT
LAMLINFLLHLLV
MIRMANUFMATLMBRMCMECHMINMLDGMOMRBLMRMTL
NICNONTS
OCOPHOPP
ACREAIR CONDITIONINGACOUSTICALACOUSTICAL CEILING PANEL SYSTEMACOUSTICAL CEILING TILEAMERICAN DISABILITIES ACTADJUSTABLEABOVE FINISH FLOORALTERNATEALUMINUMAPPROXIMATELYARCHITECTAT VARIANCE WITHACOUSTICAL WALL COVERINGACOUSTICAL WALL TILE
BETWEENBUILDINGBOTTOM OFBOTTOM OF STEELBRICKBEARINGBUILT UP ROOF
CABINETCORNER GUARDCOAT HOOKCONTROL JOINTCENTER LINECEILINGCLOSETCONCRETE MASONRY UNITCLEAN OUTCONCRETECONSTRUCTIONCONTINUOUSCARPETCERAMIC TILECONDENSING UNIT
DRINKING FOUNTAINDIMENSIONDOWNDRAWINGDRAWER
EACHELECTRIC DRINKING FOUNTAINEXTERIOR INSULATION FINISH SYSTEMEXPANSION JOINTELECTRICALEDGE OF FOOTINGEDGE OF SLABEQUALEQUIPMENTELECTRICAL WATER COOLEREXISTINGEXPANSIONEXTERIOR
FLOOR DRAINFIRE EXTINGUISHERFIRE EXTINGUISHER CABINETFINISH FLOORFIRE HOSE CABINETFACE OF STUDFLOOR JOINTFIRE RATEDFIBERGLASS REINFORCEDFOOT/FEETFOOTINGFIELD VERIFYFABRIC WALL COVERING
GAUGEGALVANIZEDGRAB BARGROUND FAULT INTERRUPTGLASS FIBER REINFORCED CONCRETEGLASS FIBER REINFORCED GYPSUMGRAVELGYPSUMGYPSUM BOARD
HOSE BIBHAND DRYERHANDICAPHARDWAREHOLLOW METALHORIZONTALHOURHEATING / VENTILATION / AIR CONDITIONING
INTERIORINSULATION
JANITORJOINT
LAMINATELINOLEUM FLOORINGLONG LEG HORIZONTALLONG LEG VERTICAL
MIRRORMANUFACTURERMATERIALMODIFIED BITUMEN ROOFINGMEDICINE CABINETMECHANICALMINIMUMMOULDINGMASONRY OPENINGMARBLEMOISTURE RESISTANTMETAL
NOT IN CONTRACTNUMBERNOT TO SCALE
ON CENTEROPPOSITE HANDOPPOSITE
PCTPEJPG BDPLPLY WDPLAMPLSTPLUMPMEPNLPREFABPREMANUFPPTPTDPSFPSIPVC
QTQTY
RR/ARAGRBR&SR/WRADRB FLRECPTREINFRESBREQDRO
SCHEDSCRSDSECTSFSIMSISPECSPKRSQSTDSSSTSTNSTORSWD
TT>BTEMPTERRTLTTHRUTIT.O.T.O.R.T.O.P.T.O.S.T.O.W.TSTTDTWAC
UULUNO
VERTVCTVFVIFVTRVWC
W/WASHW/CWDWCWHWHPW/OWOMWWFWSHP
XFMR
PORCELAIN TILEPREFORMED EXPANSION JOINTPEG BOARDPLATEPLYWOODPLASTIC LAMINATEPLASTERPLUMBINGPLUMBING / MECHANICAL / ELECTRICALPANELPREFABRICATEDPREMANUFACTUREDPAINTPRESSURE TREATEDPAPER TOWEL DISPENSERPOUNDS PER SQUARE FOOTPOUNDS PER SQUARE INCHPOLYVINYL CHLORIDE
QUARRY TILEQUANTITY
RISERRETURN AIRRETURN AIR GRILLERUBBER BASEROD AND SHELFRIGHT OF WAYRADIUSRUBBER FLOORRECEPTACLEREINFORCED / REINFORCINGRESILIENT BASEREQUIREDROUGH OPENING
SCHEDULESCREENSTORM DRAINSECTIONSQUARE FEET / FOOTSIMILARSOUND INSULATIONSPECIFICATIONSPEAKERSQUARESTANDARDSTAINLESS STEELSTAINSTONESTORAGESTACK WASHER / DRYER
TREADTONGUE AND GROOVETACK BOARDTEMPEREDTERRAZZOTOILETTHROUGHTHERMAL INSULATIONTOP OFTOP OF ROOFINGTOP OF PLATETOP OF STEELTOP OF WALLTACK STRIPTOILET TISSUE DISPENSERTHROUGH WALL AIR CONDITIONER
UPHOLSTERYUNDERWRITERS LABORATORYUNLESS OTHERWISE NOTED
VERTICALVINYL COMPOSITION TILEVINYL FLOORINGVERIFY IN FIELDVENT THROUGH ROOFVINYL WALL COVERING
WITHWASHERWATER CLOSET / TOILETWOODWALL COVERINGWATER HEATERWALL HUNG HEAT PUMPWITHOUTWALK OFF MATWELDED WIRE FABRICWATER SOURCE HEAT PUMP
TRANSFORMER
GENERAL NOTESA. ALL WALLS ARE DIMENSIONED TO FACE OFSTUD OR MASONRY UNLESS OTHERWISE NOTED.
B. FOR WHERE DOOR DIMENSIONS ARE NOTDESIGNATED; AS SHOWN ADJACENT TO WALL, SETDOOR 4" FROM WALL TO JAMB INCLUDING FRAME.WHERE SHOWN IN MIDDLE OF WALL, SET DOOR INCENTER OF SAME WALL.
C. UNLESS NOTED OTHERWISE ALL FURNITURE ISNOT IN CONTRACT AND SHOWN FOR INFORMATIONPURPOSES ONLY.
D. PROVIDE BLOCKING FOR ALL WALL MOUNTEDFIXTURES, CASEWORK, ACCESSORIES ASREQUIRED.
E. GENERAL CONTRACTOR SHALL REVIEW &IMPLEMENT U.L. RATED ASSEMBLIES NOTEDHEREIN.
EXIT
EXIT
TRAV
EL D
ISTA
NC
E 75
FEE
T M
AX
EXIT
FEC
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
As indicated
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:0
3 PM
A0.0
ABBREVIATIONS &GENERAL NOTES
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"A0.01 LIFE SAFETY PLAN
REVISIONS
REF.
D W D W
DW
E9-0658
E2-0095
E1-1073 @FASTENERS
E9-0652
DOW 995SEALANT(NB YKK)
E2-0084
E2-0081
PC-1424
3/8" x 2" HH RAWLTAPPER (SEAL HEAD)
WEEP HOLES
SHIM &SEALANT(NB YKK)
E9-0619
5" [127.00]
D.L.O.
2 1/2" [63.50]F.H.
5/8" [15.88]
F.O.
3/8" [9.53] MAX
SHIM SPACE
@ FLASHING
A3.1
1
A3.1
4
A3.12A3.1 3
E E E
104A
A5.1 4
-
-
LUCKY SAVANNAH
101
FACILICARE
102
1/2 BATH
103
PRIVATE RESTROOM
104
STORAGE
105CONFERENCE ROOM
106
1A4.1
A5.11
A
AA
101A
STORAGE
103A
BREAK ROOM
109
7' -
2"4'
- 6"
3' -
1"
STO
RAG
E
OPEN DESK WORK AREA
3
A5.1
110A
STORAGE
106B
102A
CONCRETE PAD@ CU-1
5FT. HIGH SECURITY FENCEAROUND CU-1WITH FENCING ROOF.
A
101D
12' - 5" 10' - 4" 1' - 10" 12' - 3" 3' - 0" 6' - 10"
8' -
2"
LINEN ROOM
110
COREY
111
11' -
6"
17' - 6"
8' - 10"
4' -
5"
4' -
5"
9' - 5"
4' -
0"7'
- 2"
7' - 0"
7' -
3 7/
8"
9' - 6"
VIF
12' -
5 1
/2"
7' - 6"
5' -
6"
2' -
4"5'
- 7"
5' - 0"
3' -
6"
3' - 0" 7' - 8"
1' - 7"
2' -
0"
14' - 0"
20' - 0"
110C
106A
5' - 8"
----
VIF
14' -
1 1
/2"
6FT HIGH WALL
7FT HIGHWALLS
5FT HIGHWALLS
YKK YHS-50 OREQUAL
YHS-50 STOREFRONTDOOR OR EQUAL.
1' -
8 1/
2"
2' -
4"8'
- 0"
5
A5.1
3
A4.1
6
A5.1
E101
E E E
E102
E103
E104
E105
E106E107
3' -
5"
2' -
11 1
1/16
"
1' -
0 11
/16"
12' - 4"
REMOVE EXISTING WALL/PREP FOR NEWSTOREFRONT
REMOVE WALL IN ITSENTIRETY
- REMOVE SUSPENDED CEILING IN THIS AREA- REMOVE HARD CEILING IN THIS AREA- REMOVE FLOORING AND PREP FOR NEW- REMOVE ALL LIGHTING- REMOVE WALL PANELING
- REMOVE SUSPENDED CEILING IN THIS AREA- REMOVE HARD CEILING IN THIS AREA- REMOVE FLOORING AND PREP FOR NEW- REMOVE ALL LIGHTING- REMOVE WALL PANELING
- REMOVE SUSPENDED CEILING IN THIS AREA- REMOVE HARD CEILING IN THIS AREA- REMOVE FLOORING AND PREP FOR NEW- REMOVE ALL LIGHTING- REMOVE WALL PANELING
REMOVE EXISTINGHVAC EQUIPMENT REMOVE EXISTING WATER
HEATER
- REMOVE HARD CEILING IN THIS AREA- REMOVE FLOORING AND PREP FOR NEW- REMOVE ALL LIGHTING- REMOVE WALL PANELING
REMOVE AND CAPALL PLUMBINGFIXTURES
SAW CUT ANDREMOVE SLAB FORNEW PLUMBING
REMOVE PORTION OF WALLAND PREP FOR NEWSTOREFRONT DOOR.
1' -
11"
VER
IFY
R.O
. REQ
UI R
EMEN
T
8' -
0"
REMOVE PORTION OF WALL.PREP FOR NEW DOOR
REMOVE ALL DUCT WORKTHROUGH OUT ENTIREBUILDING
REMOVE EXISTING ELEC. PANEL
REMOVE EXISTINGSTOREFRONT DOOR ANDTRANSOM
REMOVE EXISTING DOORS.PREP FOR NEW DOORS/WINDOWS
HEAD JAMB SILL
E9-0651
E2-0084
DOW 995SEALANT(NB YKK)
E1-1073
SHIM &SEALANT
(NB YKK)
E2-0081
5" [127.00]
DOW 995SEALANT(NB YKK)
E1-1073 @FASTENERS
E9-0651SHIM &SEALANT(NB YKK)
(2)PC-1220
E2-0081
E2-0084
5" [127.00]
3/8" [9.53] MAX W/3/8" DIA. FASTENER.
1/4" MAX W/ 1/4"DIA. FASTENER.
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:1
2 PM
A1.1
FLOOR PLANS
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"A1.11 FLOOR PLAN
1/4" = 1'-0"A1.12 DEMO PLAN
REVISIONS1 Date 1 Revision 1
STOREFRONT DETAILS
1A4.1
3
A5.1
SLO
PE 1
/8" /
FT.
SLO
PE 1
/8" /
FT.
DUROLAST MEMBRANE.COLOR GREY
CONT. PREFINISHEDMETAL DRIP EDGE
----
5
A5.1
3
A4.1
6
A5.1
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:2
5 PM
A1.2
ROOF PLAN ANDSCHEDULES
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"A1.21 ROOF PLAN
EXISTING ROOF TO REMAIN.REPAIR AS NEEDED WITHASPHALT SHINGLES TO MATCHEXISTING
EXISTING ROOF TO REMAIN.REPAIR AS NEEDED WITHASPHALT SHINGLES TO MATCHEXISTING
NEW CANVAS CANOPY NEW CANVAS CANOPY NEW CANVAS CANOPY
Door ScheduleMark Width Height Elevation Fire Rating Comments
101A 3' - 0" 7' - 0"101D 2' - 0" 6' - 8"102A 3' - 0" 7' - 0"103A 3' - 0" 7' - 0"104A 2' - 6" 7' - 0"106A 3' - 0" 7' - 0"106B 3' - 0" 7' - 0"106C 3' - 0" 7' - 0"106D 8' - 0" 8' - 0"110A 3' - 0" 7' - 0"110C 3' - 0" 7' - 0"
REVISIONS
FLOOR PLAN0' - 5"
UNDERSIDE OF RIDGE16' - 3"
GRADE0' - 0"
UNDER SIDE OF EAVE10' - 11"
RIDGE17' - 9"
1A4.1
EXISTING SIGN POLE EXISTING ROOF
EXISTING BRICKREPOINTED
EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW
REMOVEEXISTING DOORINFILL WALL WITH TABBYTO MATCH EXISTING
REPAIR EXISTING TABBYAND PAINT
NEW STOREFRONT DOORMATCH EXISTINGSTOREFRONT FRAMECOLOR
11' - 9" 7' - 9"
5
A5.1
FLOOR PLAN0' - 5"GRADE0' - 0"
RIDGE17' - 9"
SCRAPE, SAND AND PAINTEXISTING GABLE END.
REPAIR EXISTING TABBY AS REQUIRED.PAINT
EXISTING EAVES SHALL BESCRAPED, SANDED AND PAINTED
EXISTING SIGN POLE.SCRAPE, SAND, AND PAINT
CU-1
3
A4.1
6
A5.1
FLOOR PLAN0' - 5"GRADE0' - 0"
RIDGE17' - 9"
3' - 0"
7' -
0"
NEW STOREFRONT
NEW CANVASAWNINGS
SCRAPE, SAND AND PAINTEXISTING GABLE END.
REPAIR EXISTING TABBY AS REQUIRED.PAINT
EXISTING EAVES SHALL BESCRAPED, SANDED AND PAINTED
EXISTING SIGN POLE.SCRAPE, SAND, AND PAINT
CU-1
3
A4.1
6
A5.1
FLOOR PLAN0' - 5"
UNDERSIDE OF RIDGE16' - 3"
GRADE0' - 0"
UNDER SIDE OF EAVE10' - 11"
RIDGE17' - 9"
1A4.1
REPAIR EXISTING SHELL STUCCOAND PAINT
REPAIR EXISTING SHELL STUCCOAND PAINT
EXISTING ROOF
3
A5.1
CU-1
----
5
A5.1
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:3
5 PM
A3.1
EXTERIORELEVATIONS
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"A3.11 FRONT ELEVATION
1/4" = 1'-0"A3.12 RIGHT ELEVATION
1/4" = 1'-0"A3.13 LEFT ELEVATION
1/4" = 1'-0"A3.14 BACK ELEVATION
REVISIONS
FLOOR PLAN0' - 5"GRADE0' - 0"
RIDGE17' - 9"
G1 G1
G1G1
G1
G1 G1 G1
G1G1
EXTEND WALL UP TOUNDERSIDE OF ROOFDECK
EXISTING STUCCO CEILING TOREMAIN. GC TO REPAIR AS NEEDED
R-30 SPRAY FOAM INSULATION
OPEN TRUSSES IN WORK AREA
SEE DETAIL FOR INSULATION @ TRUSS DETAILS
A5.12
3
A4.1
EXISTING TRUSSES
EXISTING ROOF ANDDECKING
R-30 SPRAY FOAMINSULATION. SHAVEFLUSH WITH TRUSSCHORD AND PAINT.
FLOOR PLAN0' - 5"
GRADE0' - 0"
NEW TABBY EXTERIORFINISH TO MATCHEXISTING
8X16 CAST IN PLACE CONC. HEADERWITH 4 #5 STEEL REBARREINFORCEMENT. EXTEND 16": BEYONDOPENING BOTH SIDES.
ROLLING DOOR. COLOR - WHITE.
EXISTING CONC. SLAB
EXISTING 8" CONC. BLOCKWALL WITH TABBY EXTERIORFINISH
STORAGE
105 EXTERIOR
8' -
0"
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
As indicated
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:3
7 PM
A4.1
BUILDING SECTION
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/2" = 1'-0"A4.11 Section 1
1" = 1'-0"A4.12 TRUSS DETAIL
REVISIONS
3/4" = 1'-0"A4.13 GARAGE DOOR DETAIL
REF.
D W D W
DW
BREAK ROOM
109
1/2 BATH
103
PRIVATE RESTROOM
104
7' -
7"
7' - 3"
TPD-1
GB-1
TPD-1
SD-1
CT-1
PTD-1
R 2' - 6"
104A
103A
PTD-2
SD-1
GB-2
M-1
M-1CT-1
1' -
6"
UNDER SIDE OF EAVE10' - 11"
4' - 0"
2' -
0"1'
- 1
1/2"
ALUMINUM 3/8"SUSPENTION ROD
4FT X 2 FT X 3/8" ALUMINUMSIGN BASE.PAINT BLACK TO MATCHEXISTING SIGN POLE. LUCKYSAVANNAH SIGN ATTACHED.
EXISTING SIGN POLE
4FT X 2 FT X 3/8" ALUMINUMSIGN BASE.PAINT BLACK TO MATCHEXISTING SIGN POLE.FACILICARE SIGN ATTACHED.
48-6 FRONTAGE ON E BROAD38 FRONTAGE ON HARRIS ST.
TPD-1 - TOILET PAPER DISPENSER - BOBRICK
PTD-1 - PAPER TOWEL DISPENSER SURFACE MOUNTED - BOBRICK
PTD-2 - PAPER TOWEL DISPENSER SEMI RECESSED - BOBRICK
GB-1 - 42" GRAB BAR - BRUSHED STAINLESS STEEL
GB-2 - 36" GRAB BAR - BRUSHED STAINLESS STEEL
CT-1 - COAT HOOK - BOBRICK
SPD-1 - SOAP DISPENSER - SURFACE MOUNTED - BOBRICK
MI-1 - ADA COMPLIANT MIRROR - BRUSHED STAINLESS - BOBRICK
NOTE: ALL ACCESSORIES LISTED ARE BOBRICK OR EQUAL.GC SHALL SUBMIT SUBSTITUTIONS TO ARCHITECT FOR APPROVAL.
FLOOR PLAN0' - 5"
UNDER SIDE OF EAVE10' - 11"
3' - 0"
2' -
6"
7' -
0"
FLOOR PLAN0' - 5"
GRADE0' - 0"
1.5"X1.5" CLEAR ANODIZEDALUMINUM FRAME WITHWELDED JOINTS
1' -
10 3
/16"
CANVANS AWNING COVER.COLOR - MARINE BLUE
0' -
4"
1/2" STAINLESS BOLTSTHRU EXISTING CONC.BLOCK WALL.2 PER FRAME
PREFINISHED METAL FLASHINGIN BED OF CONT. MASTIC.COLOR - CLEAR ANODIZEDALUMINUM
8' -
0"
5x5x3/8 STEEL ANGLE.8" EMBED EACH SIDEOF OPENING
7' -
0"
FLOOR PLAN0' - 5"
GRADE0' - 0"
EXISTING BLOCK WALLWITH TABBY EXTERIORFINISH
NEW 3/4" TABBYFINISH TO MATCHEXISTING
8" BLOCK INFILL .HORIZ. LADDERREINF. @ 24" O.C.FILL ALL CELLS SOLID
METAL HATCHANNELS @16"O.C.
1/2" GYP.BOARD
EXISTINGCONC. SLAB.
DOWEL INTO SLAB @ 16"O.C. WITH 1 #5 BAR.EMBED INTO SLAB 8" MIN.EPOXY GROUT
FLOOR PLAN0' - 5"
GRADE0' - 0"
2' - 6"
3' -
4"
2' - 9"
1.5"X2" STEEL FRAME. PAINT BLACK
VERT. STEEL FRAME.BEYOND. PAINT BLACK
BOLT FRAME TO CONC. SLAB1/2" GALV. BOLT @ 16" O.C..EPOXY GROUT IN SLAB4" CONC. SLAB W/
STEEL MESHREINF.
STEEL SCREEN.SPOT WELD TOSTEEL FRAME.SEE ATTACHEDSPEC SHEET FORSCREEN DETAILS
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
As indicated
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:3
8 PM
A5.1
WALL SECTIONSAND DETAILS
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/2" = 1'-0"A5.11 ENLARGED PLAN - RESTROOMS - BREAKROOM
1/2" = 1'-0"A5.13 DETAIL @ SIGN POLE
BATH ACCESSORIES
SEE A0.0 FOR ALL MOUNTING HEIGHTS.
3/8" = 1'-0"A5.14 FACILICARE ELEVATION
REVISIONS
1" = 1'-0"A5.12 CANOPY DETAIL
3/4" = 1'-0"A5.15 WALL SECTION @ EXISTING DOOR INFILL
1" = 1'-0"A5.16 HVAC SCREEN DETAIL
(2) 4X2 SIGNS16 TOTAL SQ.FT. OF SIGN
GFI
GFI
GFI
REF.
D W D W
TD TD
TD
TD
TD
TD
TD TD
TDTD
TD TD
TDTD
TD
TD
GFI
GFI
GFI
TD
TD
TD TD
TD
DW
TV
TD
GFI
A3.1
1
A3.1
4
A3.12A3.1 3
A5.1 4
-
-
1A4.1
3
A5.1
EXISTING GYP CEILINGEXISTING GYPCEILING
EXISTING GYP CEILING
EXISTING GYP CEILING
EXISTING GYPCEILING
EXISTING GYPCEILING
----
5
A5.1
3
A4.1
E E E
104ALUCKY SAVANNAH
101
FACILICARE
102
1/2 BATH
103PRIVATE RESTROOM
104
STORAGE
105CONFERENCE ROOM
106
A
A
A
101A
1 2
3 4
5 6
RECEPTION AND WAITING
PANEL A200AMPPANEL
DISCONNECTJ
CU-1
2X2 FLUORESCENT FIXTURE
2X4 FLUORESCENT FIXTURE
LINER DOWNLIGHT BY CK LIGHTING OR EQUAL
TRACK LIGHTING
EMERGENCY WALL LIGHT WITH BATTERY BACKUP
ELECTRICAL PANEL
CABLE TV OUTLET
TELE/DATA OUTLET
DUPLEX OUTLET
GFI DUPLEX OUTLET
SINGLE POLE SWITCH
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
13:5
4 PM
E1.1
POWER ANDLIGHTING PLANS
14032/26/2014
TLC
JFW
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"E1.11 FIRST FLOOR LIGHTING
1/4" = 1'-0"E1.12 POWER PLAN
ELECTRICAL LEGEND
REVISIONS
GFI
GFI
GFI
AHU- 1
CU- 1
SPIRAL DUCTRUN ABOVE BOTTOMCHORD OF TRUSSES
EF-1
EF-1
DUCT OUT TO GABLE ENDINSTALL DUCT CAP WITHBUG SCREEN
0' -
10"
3' -
0"
8" FLEX DUCT 8" FLEX DUCT
6" F
LEX
DU
CT
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
14:0
7 PM
M1.1
MECHANICAL PLAN
14032/26/2014
Author
Checker
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"M1.11 MECHANICAL PLAN
REVISIONS
REF.
D W D W
DW REF.
D W D W
DW
4" PVC
4" PVC
4" PVC
2" PVC
2" PVCF.C.O.
TIE INTO EXISTING 4"SANITARY LINECOORDINATE IN FIELD
FDFD
2" PVC4" PVC
2" PVC
LAUNDRYCONN.
HWCW
HW
CW
CWHOSE BIB
HOSE BIB
HW
WATER HEATERLOCATION IN ATTIC SPACE
CONNECT TOEXISTING DOMESTICWATER SUPPLY LINE.COORDINATE INFIELD
DOWN TOHOSE BIB
DOWN TOHOSE BIB
CW
CW
CW
HW
CW
SCALE:
PROJECT NUMBER:
DATE:DRAWN BY:
CHECKED BY:
1. This Drawing is the property of Wubbena A&D PC. and is not to be reproduced or copied inwhole or in part. It is not to be used on any other project and is to be returned on request.
2. Scales as stated hereon are valid on the original drawings only and are hereby changed inproportion to the difference in size between the print and the original drawing.
3. Do not scale dimensions from prints. Plans and details are not always to scale.Use dimensions given or consult the Architect for further clarification.
COPYRIGHT & REPRODUCTION OF DRAWINGS
SHEET NO.
SHEET TITLE
James Wubbena, AIA35 Barnard St., Ste. 300
Savannah, GA. 31401P - 912 660 5438F - 912 525 3088
1/4" = 1'-0"
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
6/19
/201
4 4:
14:1
0 PM
P1.1
PLUMBING PLANS
14032/26/2014
Author
Checker
RE
NO
VA
TIO
NS
AN
DT
EN
AN
T IM
PR
OV
EM
EN
TS
FOR
FA
CIL
ICA
RE
AN
DLU
CK
Y S
AV
AN
NA
H31
7 E
. BR
OA
D S
TR
EE
TSA
VA
NN
AH
, GE
OR
GIA
MICHAELCONNOR
1/4" = 1'-0"P1.11 PLUMBING PLAN - SANITARY
1/4" = 1'-0"P1.12 PLUMBING PLAN - DOMESTIC WATER
REVISIONS
SHEET NO.
PROJECT NUMBER:
DATE:
DRAWER:
PROJECT CONTACTS
RENDERING SHOWN ON THIS SHEET IS FOR GRAPHIC REFERENCE ONLY AND IS NOT A CONSTRUCTION DRAWING
INDEX OF DRAWINGSSHEET ISSUEDSHEET REVISEDSHEET REMOVED
SHEET PROVIDED BY:
PLAN REVIEW DATA VICINITY MAP
?
35 BARNARD STREETSUITE 300SAVANNAH, GA 31401912 660 5438WWW.WUBBENAPC.COM
ALL DRAWINGS AND INFORMATION CONTAINED IN THIS SET OF DOCUMENTS IS THE PROPERTY OF WUBBENA ARCHITECTS AND DESIGN.NO DUPLICATION OR USE OF THESE DOCUMENTS IS PERMITTED WITHOUT WRITTEN PERMISSION FROM WUBBENA A&D.
DOCUMENTS SHALL ONLY BE USED FOR THE PROJECT ADDRESS AND SHALL ONLY BE USED BY CLIENT LISTED ON DOCUMENTS.ONLY DOCUMENTS STAMPED "RELEASED FOR CONSTRUCTION" SHALL BE USED FOR PERMITTING OR CONSTRUCTION.
ALL DESIGNS WITHIN ARE THE INTELLECTUAL PROPERTY OF WUBBENA ARCHITECTS.6/19
/201
4 4:
14:2
1 PM
N:\W
ubbe
na A
D\1
403
East
bro
ad s
t\eas
tbro
ad s
treet
revi
sed
4-21
.rvt
T1.1
2/26/20141403
REN
OVA
TIO
NS
AND
TEN
ANT
IMPR
OVE
MEN
TS F
OR
FAC
ILIC
ARE
AND
LUC
KY S
AVAN
NAH
317
E. B
RO
AD S
TREE
TSA
VAN
NAH
, GEO
RG
IA
OWNER
MICHAEL CONNERFACILICARE SAVANNAH
ph: 912-236-0031fax: 912-236-2717
ARCHITECT
WUBBENA AD, P.C.JIM WUBBENA, AIA
35 BARNARD ST., STE. 300SAVANNAH, GA. 31401
PH.912 660 5438FX 912 525 3088
ADOPTED CODES AND STANDARDS:
-NFPA 220 STANDARD OR TYPES OF BUILDING CONSTRUCTION- INTERNATIONAL BUILDING CODE 2012- ASNI BHMA (BUILDERS HARDWARE MFR'S ASSOC.)- NATIONAL ELECTRIC CODE- SMACNA HVAC 1995- GA. ACCESSIBILITY CODE FOR BUIDLINGS AND FACILITIES
BUILDINGS - 1
ZONING - RIP1
IBC - TYPE III B NON SPRINKLERED CONSTRUCTION
TYPE OF OCCUPANCY - NEW BUSINESS OCCUMPANCYNFPA 101 LIFE SAFTY CODE 2012 EDITION
TOTAL TENANT AREA - 1600 SQ.FT.
TOTAL OCCUPANT LOAD = 1/300 SQ.FT. - STORAGE1/100 SQ.FT. - OFFICE SPACES
LOAD BY SQ.FT. PER PERSON - 16 PERSONS
EXITS REQUIRED - ONE (1)
EXITS FURNISHED - TWO (2)
MAXIMUM TRAVEL DISTANCE TO EXIT ALLOWED - 100 FEETMAXIMUM TRAVEL DISTANCE FURNISHED - 48 FEET
ARCHITECTURALSheet
Number Sheet Name Sheet Issue Date
A0.0 ABBREVIATIONS & GENERAL NOTES 2/26/2014A1.1 FLOOR PLANS 2/26/2014A1.2 ROOF PLAN AND SCHEDULES 2/26/2014A3.1 EXTERIOR ELEVATIONS 2/26/2014A4.1 BUILDING SECTION 2/26/2014A5.1 WALL SECTIONS AND DETAILS 2/26/2014
TITLE SHEETSheet
Number Sheet NameSheet Issue
Date
T1.1 TITLE BLOCK 05/12/06
PLUMBINGSheet
Number Sheet Name
P1.1 PLUMBING PLANS
MECHANICALSheet
Number Sheet Name
M1.1 MECHANICAL PLAN
ELECTRICALSheet
Number Sheet Name
E1.1 POWER AND LIGHTING PLANS
RENOVATIONS TO 317 E.BROAD STREET