Remote Open/ close valves. built sensor power supply l5-24V DC]. · 2018. 8. 13. · • Remote...

5

Transcript of Remote Open/ close valves. built sensor power supply l5-24V DC]. · 2018. 8. 13. · • Remote...

  • • Remote Open/ close valves.

    • lח built sensor power supply l5-24V DC].

  • Pressure sensor #1

    USB

    Pre,aure 1ensor 11

    Technical Specifications:

    GENERAL

    Power supply ................................................................. 7 ,2v 14AH lithium pack

    Or28AH

    IP Protection ....... .. .... . .. ... .............. ... ......... . ...... IP68, Tested under 2

    Meters during 100 days

    Operating temperature ............................................... -20°C to +75 °C

    Sim Card Slot

    nterna l power sou rce ו

    ANALOG I N PUTS

    Number ......................................................... 2

    Resolution ...................................................... 1 6 bits

    Precision ...................................................... 0.1 %

    Range ............................................................. 0-1 Ov or 4/20mA

    GSM modem ................................................................. Centurion BG52, quad band

    lmpedance ................................... ............... Voltage mode 2m [1m

    4/20mA mode 125[1

    Real time clock ............................................................. high precision +2ppm NTP

    Se lf- synchronization

    DIGITAL INPUTS

    Number ........................................................................... 4 [Alarm, Counter, Flow)

    SENSOR POWER SUPPLY

    Number ........................................... 2

    Range ................................................. 5 to 24v

    lnput protection ........................................................... .. Protected against Reverse Precision ............................................ 1%

    Connection and over voltage Max current ........................................ 40mA

    INTERNAL PRESSURE SENSOR

    ESTIMATED OPERATING TIME* Number ........................................... 2

    Range ................................................. 0-20barlnput

    Logging

    Resolution

    Precision ........................................... 0.4%

    Transmission Use Time

    1 Flow 5 minutes 1 Per Day 10 years

    1 Flow & 5 minutes 1 Per Day 8 years

    1 Pressure

    * Tested with one 7.2V/14aH battery pack.

  • Manu Synoptic GIS