2 3 4
Press [programming setting] for 3 seconds,
enter into setting status, LED light on.
Choose remote control channel, press [chan-
nel setting] button, LED flash quickly.
Programming setting
◆Method two:Change direction by programming button
Press programming button, setting done,
LED light off.
Attention: Repeat this operation for max 16 channel remote control channel setting.
Direction change
◆Delete limit and remote control channel
Press programming button for 3 seconds, en-
ter into setting status, LED light on.
Press programming button for 7 seconds,
delete all setted channel to EXW mode.
LED light off.
Short time press twice+ long time press [programming button] twice: short time press ( light
flash) + short time press(light flash) + long time press for 3 seconds ( led light on) + long
time press for 3 seconds ( led light off, motor indicate by vibration ) direction change done
① ②
① ②
◆Method one:
Press [programming] button for 3 seconds, e-
nter into setting status, LED light on.
Press [ ] + [stop] button,
LED light flash quickly.
Channel Choose Left
Press [programming button], direction change
done, LED light off.
③
① ②
YR2118B transmitter function
Remote control setting
Basic remote control setting
Before using transmitter, user must set “ remote control channel”, save the transmit cha-
nnel in motor.
If you need to set all previous remote channel invalid, please do “delete remote control”
setting
Transmitter’s open and close function is corresponding with curtain’s open and close dir-
ection. If it’s opposite operation, please do “ direction change” setting.
1.Max 16 channels can be recorded in each motor. The motor will response to setted r-
emote channel when receive signal.
2.When two motor are used in one track, set same channel for those two motors and re-
mote control them on that channel. This setting doesn’t affect those two motor’s single co-
ntrol function.
3.Each RAEX motor is compatible with Raex transmitter. YR2188B with more function, li-
ke intermediate stop position function. So YR2188B is strongly recommened on installation
and setting.
3V CR2032
◆Remote control function
Press transmitter [open] button, open the cur-
tain, motor will move to the open position, st-
op by locked -rotor or stop automatically after
3 minutes running.
Press [close] button, close the curtain, motor
move to the close limit position, stop by locked
-rotor or stop automatically after 3 minutes ru-
nning
Press [stop] button during the process of open
or close, motor stop immediately.
③
① ②
◆Set 3 stop positions
Press [channel setting]+ [intermediate stop 1 button] or [channel setting]+ [up tilting/ 75%]
button, motor vibrate one time.Set the current
position as stop position 1, stop position 1 will
be 75% limit position.
Press [channel setting] + [intermediate stop
3 button] or [channel setting] +[horizontal tilt-
ing/ 50%],motor vibrate one time.Set the
current position as stop position 3, stop pos-
ition 3 will be 50% limit position.
Press [channel setting] + [intermediate stop 2
button] or [channel setting] + [down tilting/ 25%]
button, motor vibrate one time.Set the current
position as stop position 2, stop position 2 will
be 25% limit position.
① ②
③
◆3 equal line stop position
Press [intermediate stop position 1 button] or
[up tilting/75%] button for 0.5 seconds at the
motor stopped status, motor move to interme-
diate stop position 1 and stop automatically. In-
termediate stop 1 position is 75% of limit
position.
Press [intermediate stop 3 button] or [horizo-
ntal tilting /50%] for 0.5 second, motor move
to intermediate stop 3 position. Intermediate
stop 3 position is 50% of limit position.
Press [intermediate stop 2 button] or [down ti-
lting/25%] for 0.5 second, motor move to inte-
rmediate stop 2 position. Intermediate stop 2
position is 25% of limit position.
① ②
③
0.5S
0.5S
0.5S
◆Resume limit position
Press [channel setting] + [stop] button for 4
seconds, resume limit and intermediate stop
position, LED flash one time, motor vibrate one time,and then resume limit done.
4S4S
Limit setting
1 .After power connection,first time to open or close the curtain, the motor will stop by locked
-rotor at 0mm- 10mm to the close position. (if the track’s direction is wrong the automatic
limit tolerance will be bigger after direction change, the tolerance resume normal level. )
2.At stop status, power off and then connected , if no pulling curtain during power off, motor
limit status no any change, the motor won’t crash to the end of track. If the pulling the cur-
tain too big distance, after power connection , the motor may crash to the end of track and
then resume limit. Power off during the motor’s moving process, the motor will resume li-
mit after crash to end of track for the first time running.
◆Adjust the close limit position
( adjust the limit position after automatic limit )
Long press [channel setting] and [close] button for 4s,enter into close limit adjustment status,
motor vibrate one time,LED light on.
Within 30 seconds, repeat pressing [open],
[stop] or [close] button, move to the position
wanted.
Press [channel setting button] for 4 seconds
or press programming button, set the current
position as close limit position, out of the st-
atus of adjust close limit position, motor vibr-
ate one time, LED light off.
① ②
③
4S
4S
4S
◆Adjust open limit position
(adjust the limit after automatic limit )
5
Long press [channel setting] and open button for 4s,enter into open limit adjustment status,
motor vibrate one time,LED light on.
Within 30 seconds, repeat press [open],
[stop] and [close] button, move to the posit-
ion wanted.
Press channel setting for 4 seconds or press
programming button,set the current position
as open limit position, out of the status of a-
djust open limit position, motor vibrate one time,LED light off.
① ②
③
4S
4S
4S
+ +
+
+
+
+
或
或
+ + +3S
3S
3S
3S 3S
◆Limit setting automatically
7S
(back)
(back) (back)
(back)
(back)
(back)
(back)
(back)
(back)
Channel Choose Left
Channel
Channel Choose Right
Up/Open
Stop
Down/Close
Up tilt/75%
Horizontal position/50%
Down tilt/25%
Channel setting
③
6 7 8
Press [stop] + [open] button for 4 seconds u-
ntil LED light on, motor vibrate shortly. Within
3 seconds, press channel setting of the tran-
smitter’s back , motor vibrate shortly, operati-
on done, switch on this function.
Press [stop]+ [close] button for 4 seconds un-
til LED light on, motor vibrate shortly. Within 3
seconds, press channel setting on the trans-
mitter’s back , motor vibrate shortly, operation
done, switch off this function.
Touch control function
◆Intelligent protocol operation
( it is valid when connect the intelligent module and exchange to current
protocol )
1.After motor stopping, motor reversal for 1-5 times, then pull the curtain manually.
2.When stop at any position , wait for 1-2 seconds, open or close the curtain by manual.
Intelligent protocol
① Allows manual activation ② ban manual activation
◆Release function
Press [SW1] button ,red LED light flash 1-5
times
Open the motor bottom, press [SW1] for 3 s-
econds, the blue light LED on, enter into ex-
change status.
②
①
Hotel management function
③.After the touch control function allowed , motor stop for 5 seconds, pull the
curtain on open or close direction, motor will open or close automatically.
④.Touch control function is allowed in EXW mode.
③
Press [programming button] to confirm, exch-
ange intelligent protocol done, blue light LED
off, according to the current protocol, the red
LED flash 1- 5 times.
◆Exchange intelligent protocol
Short time Press [programming button] for 4
times, and then long time press programming
button for 3 seconds, the red Led light flash 1 time.The blue LED flash for 10 times after
adding net successfully.
Short time Press programming button for 3 tim-
es, long time press programming button for 3
seconds, the red Led light flash 1 time.The red
and blue LED flash alternately after clearing
net successfully.
① Add net ② Clear net
③.Support open, stop, close control, percent control, response to open, stop,
close and percent status feedback.
④.Support manual operation, direction change and delete limit function.1.The third port which close to LED , from the high voltage to low voltage, close the curtain.
2.The third port which close to LED , from the low voltage to high voltage, open the curtain.
Press channel setting for 5 seconds, enter in-
to speed change status, LED light on.
Press [open] button for 5 seconds, choose
110 rpm;
Press [stop] button for 5 seconds, choose
90 rpm;
Press [close] button for 5 seconds, choose
70 rpm;
LED light flash 3 times and then light off.
Choose speed ( EXW speed is 70 rpm )
5S
5S
User instructions
MP60-2.0/70EA
5S
5S
4S
4S
4S
4S
Switch control
1.Brown and blue wire connected with 220V AC,black wire not connected,open the curtain.
Cut off the connection between brown wire and 220V AC,stop the curtain
2.Black and blue wire connected with 220V,black wire not connected,close the curtain.
Cut off the connection between brown wire and 220V AC,stop the curtain
Live L WhiteOpen L1 BlackClose L2 BrownNeutral N Blue
Connection diagram
Port definition
1.GND ( Ground)
2.External switch (open )
3.External switch (close )
4.Room card checking ( hotel management )
5.A+(485)
6.B- (485)
3SSW1
EXW status
Tuya wifi universal protocol , flash 1
time
RAEX RS485
protocol, baud rate
9600 flash twice.
Exchange intelligent protocol
RAEX RS485 protocol, baud rate
19200 flash 3 times.
Z wave protocol,
flash 4 times
SW1
Exchange intelligent protocol
Exchange intelligent protocol
RAEX universal
intelligent protocol,
flash 5 times
SW1
Exchange intelligent protocol
Exchange intelligent protocol
① ②
(back) (back)
(back)
Please read the specification carefully before installation or use.
Please insta l l and ad just the product by profess ionals .
RAEX MACHINERY LIMITED
GUANGDONG RAEX INTELLIGENT TECHNOLOGY CO.,LTD.
RAEX MACHINERY LIMITED
-Unit A,2/F,On Wah Industrial Building,41 43 Au Pui Street,Fo Tan,Shatin, N.T.,HongKong.
- -Tel: 00852 26909728 Fax: 00852 26900018
GUANGDONG RAEX INTELLIGENT TECHNOLOGY CO.,LTD.
XiLi Industrial Park,DongChong Town,Nansha district,
CuangZhou,China(Post Code:511475)
- -Tel: 008620 22916189 Fax: 008620 22916154