REMOTE CONTROL M SEARCHLIGHT odel 6105012

4
Model 61050-0012 REMOTE CONTROL SEARCHLIGHT FEATURES l Constructed of noncorrosive materials l Sealed beam halogen lamp l Remote control and 15' cable included l Long life gear drive l Low amp draw l Patented clutch mechanism prevents motor damage when running against limit stops APPLICATION Ideal for boaters...locate buoys, moorings, channel markers, etc. Ideal for RV'ers...pinpoint road signs, campsites, or use as backup light. SPECIFICATIONS l 360° horizontal movement l 75° vertical sweep l White thermoplastic housing and base INSTALLATION INSTRUCTIONS LIGHT MOUNTING 1. Select a location for the light which will allow for clear beam projection. Searchlight base should be mounted on level, flat surface. 2. Using the light base mounting template enclosed, drill three pilot holes and a cable exit hole. Fasten hold down bracket on to mounting surface with screws provided, or applicable screws for your appli- cation. 3. Peel off adhesive backing from gasket and place on light mounting base with the adhesive side on the base. Feed cable through cable exit hole. 4. Slide light base on to hold down bracket while push- ing down on base, making sure metal strip on light base engages the hold down bracket. Fasten screw on the outside of the base to seal the base against the surface. NOTE: Secure cable with nylon clips or equivalent. Protect installation at points of stress and leave adequate slack where cable must be flexible. CONTROL INSTALLATION Select the best location near the helm which will allow for convenient operation of control. 1. Cut two holes (see Panel Cutout Template enclosed) for mounting control. 2. Route power leads (supplied by customer) from voltage source to control. Note: Wiring must be 16 gauge (minimum). 3. Connect positive (+) power lead to red (+) wire and negative (-) power lead to black wire using butt connectors. Be sure fuse holder in positive lead has the proper size fuse installed. 4. Plug connector from control panel to end of light cable connector. 5. Use bedding compound or sealant to waterproof control mounting. 6. Secure control with self-tapping screws provided. CIRCUIT PROTECTION A 10 amp fuse has been included in the fuse holder. Should this fuse blow, replace with the same size fuse after determining reason for blown fuse. Remote Control Unit Model Weights Standard Number Voltage Amps Fuse/Breaker Candlepower lb (kg) Carton 61050-0012 12V DC 4.5 10 100,000 5 (2.3) 4 WARNING ! Burn Hazard. Do not touch lense when light is on. Do not operate with storage cover over light. MODEL 61050-0012 155 SL

Transcript of REMOTE CONTROL M SEARCHLIGHT odel 6105012

Page 1: REMOTE CONTROL M SEARCHLIGHT odel 6105012

Model 6

1050-0012

REMOTE CONTROLSEARCH LIGHTFEATURESl Constructed of noncorrosive ma te ri alsl Sealed beam halogen lampl Remote control and 15' cable in clud edl Long life gear drivel Low amp drawl Patented clutch mechanism prevents motor damagewhen running against limit stops

APPLICATIONIdeal for boaters...locate buoys, moorings, chan nelmarkers, etc. Ideal for RV'ers...pin point road signs,campsites, or use as backup light.

SPECIFICATIONSl 360° horizontal movementl 75° vertical sweepl White thermoplastic housing and base

INSTALLATION INSTRUCTIONSLIGHT MOUNTING

1. Select a location for the light which will allow forclear beam projection. Searchlight base should bemounted on level, flat surface.

2. Using the light base mounting template enclosed,drill three pilot holes and a cable exit hole. Fastenhold down bracket on to mounting surface withscrews provided, or applicable screws for your appli-cation.

3. Peel off adhesive backing from gasket and place onlight mounting base with the adhesive side on thebase. Feed cable through cable exit hole.

4. Slide light base on to hold down bracket while push-ing down on base, making sure metal strip on lightbase engages the hold down bracket. Fasten screwon the outside of the base to seal the base againstthe surface.

NOTE: Secure cable with nylon clips or equivalent.Protect installation at points of stress and leaveadequate slack where cable must be flexible.

CONTROL INSTALLATION

Select the best location near the helm which will allow for convenient operation of control.

1. Cut two holes (see Panel Cutout Template enclosed)for mount ing control.

2. Route power leads (supplied by customer) from voltage source to control. Note: Wiring must be 16gauge (mini mum).

3. Connect positive (+) power lead to red (+) wire andnegative (-) power lead to black wire using butt connectors. Be sure fuse holder in positive lead hasthe proper size fuse installed.

4. Plug connector from control panel to end of lightcable connector.

5. Use bedding compound or sealant to waterproofcontrol mounting.

6. Secure control with self-tapping screws provided.

CIRCUIT PROTECTION

A 10 amp fuse has been included in the fuse holder.Should this fuse blow, replace with the same size fuseafter determining reason for blown fuse.

Remote Control Unit

Model Weights StandardNumber Voltage Amps Fuse/Breaker Candlepower lb (kg) Carton

61050-0012 12V DC 4.5 10 100,000 5 (2.3) 4

WARNING!

Burn Hazard.Do not touch lense when light is on. Do not operate with storage cover over light.

MODEL 61050-0012155 SL

Page 2: REMOTE CONTROL M SEARCHLIGHT odel 6105012

CLEANING OF EXTERIOR PLASTICSURFACES

Recommendation for cleaning “Exterior Surfaces” is asolution of warm water and a mild detergent soap.

CAUTION Do not use cleaners that contain esters, halogenated sol vents, aromatic solvents, ketones andstrong acids or bases.

SERVICE

BULB REPLACEMENT

1. Remove light cover by removing screw from the rearof the light housing.

2. Pull the bulb assembly from the light housing andremove rubber seal around the bulb to separate thebulb from bulb housing.

3. Unscrew terminals from bulb and connect terminalsto new bulb.

4. Replace seal ring and place bulb assembly in to thelight housing. Fasten cover with screw.

TROUBLESHOOTING

All lights are thoroughly inspected before shipping and are warranted to operate within spec i fi ca tions. If light does notoperate correctly, check fuse and wire harness connections before proceeding.

Problem Solution

Control works in reverse in all directions. Control installed upside down.

Bulb operates – no light movement. Check wiring code for proper wire color connections.

Light moves – bulb does not operate. 1. Check bulb.

Dim light 1. Check voltage at power source.2. Check wire size from source to control and for proper ground circuit.

PARTS LIST

PartDescription Number

Bulb Kit w/Seal Ring 18753-0528Directional Switch 43990-0000On/Off Switch 18753-0180Control (Complete) 60030-7009

CONTROL REPLACEMENT

Individual replacement parts are available for the controlpanel. To replace switches remove the two (2) screwsfrom front of panel and pull forward, exposing wiring.

1. To remove directional switch push firmly on the fronttoggle and remove switch from back side of panel.Defective switch, and splice wires (with butt connectors) to the new switch, being sure to matchwire colors. Note: Install switch with yellow wire ontop for correct di rec tional aiming.

2. To remove On/Off switch, unscrew ring on face ofswitch body and remove switch from panel. Connectwires to new switch the same as old switch andinstall switch.

+

WIRING CODE

TO CONTROL

YELBLUGRNBRN

YELBLUGRNPUR

TO CABLE

PRIMARY STATION 60030-7009

STATION SELECTOR PANEL

43683-0000

Cut off connectors

BLACK

ORANGE

OR

AN

GE

BLA

CK

BLA

CK

OR

AN

GE BLACK (–)

RED (+)

FLYBRIDGE CONTROL 43670-0003

INPUT LEADS SUPPLIED BY CUSTOMER (16 GA.)

SECONDARY CONTROL CABLE MUST BE AQUIRED SEPARATELY

(SEE CABLE LISTING).

43990-0028 = 50 FT. BULK

ACCESSORY CABLES

43990-0013 = 10 FT.

43990-0014 = 15 FT.

43990-0015 = 25 FT.

43990-0016 = 35 FT.

MALEFEMALE

CONNECTORS

(A) (B)

DUAL STATION INSTALLATION KIT 43670-0004

CONTROL UNIT OPERATION

SWITCH FUNCTIONS

(A) Light Switch

On/Off switch positions.

(B) Directional Switch

Lever has eight contact positions and will operatein horizontal, vertical, andin four combinations of directions.

Page 3: REMOTE CONTROL M SEARCHLIGHT odel 6105012

PANEL CUTOUT(Control Unit)Inches (Millimeters)

4.0(101.6)

3.62(92.08)

1.25(31.75)

1.31(33.34)

2.5(63.5)

1.5 Dia.(38.1)

2 Dia.(50.8)

ForwardHold-Down

Bracket

Cable ExitArea

Pilot Hole

Pilot Holes

MOUNTING TEMPLATE(Light Base)

Page 4: REMOTE CONTROL M SEARCHLIGHT odel 6105012

THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THEJABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAIL-ABLE FOR YOUR INSPECTION UPON REQUEST.

DIMENSIONAL DRAWINGSearchlightInches (Millimeters)

CONTROL UNITInches (Millimeters)

8.0(203.2)

2.5(63.5)

7.9(200.7)

4.9(124.5)

6.4(162.6)

3.2(81.3)

(101.6)

(63.5)

(21.34) (44.45)

Jabsco is a trademark of Xylem Inc. or one of its subsidiaries. © 2013 Xylem, Inc. 43000-0751 Rev. C 9/2013

www.xylemflowcontrol.com Jabsco, 100 Cummings Center, Ste. 535-N, Beverly, MA 01915 USATel: +1 978 281 0440 Fax: +1 978 283 2619Jabsco, Bingley Road, Hoddesdon, Hertfordshire, EN11 0BU UKTel: +44 (0) 1992 450 145 Fax: +44 (0) 1992 467 132NHK Jabsco Co Ltd, 3-21-10, Shin - Yokohama Kohoku-ku, Yokohama 222 JAPANTel: +81 (0) 45 475 8906 Fax: +81 (0) 45 475 8908Jabsco GmbH, Oststraße 28, 22844 Norderstedt GERMANYTel: +49 (0) 40 53 53 73 0 Fax: +49 (0) 49 53 53 73 11Jabsco Italia, s.r.l., Via Tommaseo, 6, 20059 Vimercate, Milano ITALYTel: +39 039 685 2323 Fax: +39 039 666 307