Page 1: Reinforcement  detailing

REINFORCING DETAILING OF R.C.C MEMBERS

PRESENTED BY

Er.T.RANGARAJAN,B.E,M.Sc(struct.engg),F.I.E,FACCE,LACI,LISSE,LIASE

Page 2: Reinforcement  detailing

WHO IS AN ENGINEER?

According to USA President Herbert Hoover, who was an engineer before he became a politician, said:The great liability of the engineer …compared to men of other professions……is that his works are out in the open where all can see them.His acts …..step by step …are in hard substances.He cannot bury his mistakes in the grave like the DOCTORS.He cannot argue them into thin air…..or blame the judge…..like the LAWYERS.He cannot, like the ARCHITECT, cover his figures with trees and vines.He cannot, like the politicians, screen his shortcomings by blaming his opponents….and hope the people will forget. The ENGINEER simply cannot deny he did it.If his works do not work……he is damned.

Page 3: Reinforcement  detailing

A design engineer’s responsibility should include assuring the structural safety of the design, details, checking shop drawing.Detailing is as important as design since proper detailing of engineering designs is an essential link in the planning and engineering process as some of the most devasting collapses in history have been caused by defective connections or DETAILING. There are many examples explained in the book" DESIGN AND CONSTRUCTION FAILURES by Dov Kaminetzky.Detailing is very important not only for the proper execution of the structures but for the safety of the structures.Detailing is necessary not only for the steel structures but also for the RCC members as it is the translation of all the mathematical expression’s and equation’s results.

Page 4: Reinforcement  detailing

For the RCC members for most commonly used for buildings we can divide the detailing for

1. SLABS-WITH OR WITHOUT OPENINGS.(RECTANGULAR,CIRCULAR,NON-RECTANGULAR-PYRAMID SLAB,TRIANGULAR ETC)

-BALCONY SLAB,LOFT SLAB,CORNER SLAB etc

2. BEAMS- WITH OR WITHOUT OPENIGS.(SHALLOW & DEEP BEAMS)

3. COLUMNS.(RECTANGULAR,L-SHAPE,T-SHAPE, CIRCULAR,OCTAGONAL,CROSS SHAPE etc)

4. FOUNDATIONS.

Detailing for gravity loads is different from the lateral loads specially for the SEISMIC FORCES.

Apart from the detailing for the above there is a different detailing required for the Rehabilitation and strengthening of damaged structures.

We will now dwell on the DETAILING OF MEMBERS FOR THE GRAVITY AND SOME CODAL DETAILINGS AS PER IS CODE IS 13920 AND IS 4326 AS REQUIRED FOR SEISMIC FORCES.

Page 5: Reinforcement  detailing

DO’S & DONOT’S FOR DETAILINGDO’S-GENERAL

1. Prepare drawings properly & accurately if possible label each bar and show its shape for clarity.

12”

I ¼”dia@12”c/c

Cross section of retaining wall which collapsed immediately after placing of soilbackfill because ¼” rather than 1-1/4” dia. were used. Error occurred because Correct rebar dia. Was covered by a dimension line.

1- ¼”dia@12”c/c

Page 6: Reinforcement  detailing

2. Prepare bar-bending schedule , if necessary.3. Indicate proper cover-clear cover, nominal cover

or effective cover to reinforcement.4. Decide detailed location of opening/hole and

supply adequate details for reinforcements around the openings.

5. Use commonly available size of bars and spirals. For a single structural member the number of different sizes of bars shall be kept minimum.

6. The grade of the steel shall be clearly stated in the drawing.

7. Deformed bars need not have hooks at their ends.8. Show enlarged details at corners, intersections

of walls, beams and column joint and at similar situations.

Page 7: Reinforcement  detailing

9. Congestion of bars should be avoided at points where members intersect and make certain that all rein. Can be properly placed.

10. In the case of bundled bars, lapped splice of bundled bars shall be made by splicing one bar at a time; such individual splices within the bundle shall be staggered.

11. Make sure that hooked and bent up bars can be placed and have adequate concrete protection.

Page 8: Reinforcement  detailing

12. Indicate all expansion, construction and contraction joints on plans and provide details for such joints.

13. The location of construction joints shall be at the point of minimum shear approximately at mid or near the mid points. It shall be formed vertically and not in a sloped manner.

DO’S – BEAMS & SLABS:

1. Where splices are provided in bars, they shall be , as far as possible, away from the sections of maximum stresses and shall be staggered.

2. Were the depth of beams exceeds 750mm in case of beams without torsion and 450mm with torsion provide face rein. as per IS456-2000.

3. Deflection in slabs/beams may be reduced by providing compression reinforcement.

4. Only closed stirrups shall be used for transverse rein. For members subjected to torsion and for members likely to be subjected to reversal of stresses as in Seismic forces.

Page 9: Reinforcement  detailing

5. To accommodate bottom bars, it is good practice to make secondary beams shallower than main beams, at least by 50mm.

Do’s –COLUMNS.1. A reinforced column shall have at least six bars of

longitudinal reinforcement for using in transverse helical reinforcement.-for CIRCULAR sections.

2. A min four bars one at each corner of the column in the case of rectangular sections.

3. Keep outer dimensions of column constant, as far as possible , for reuse of forms.

4. Preferably avoid use of 2 grades of vertical bars in the same element.DONOT’S-GENERAL:

1. Reinforcement shall not extend across an expansion joint and the break between the sections shall be complete.

2. Flexural reinforcement preferably shall not be terminated in a tension zone.

Page 10: Reinforcement  detailing

3. Bars larger than 36mm dia. Shall not be bundled.

4. Lap splices shall be not be used for bars larger than 36mm dia. Except where welded.

5. Where dowels are provided, their diameter shall not exceed the diameter of the column bars by more than 3mm.

6. Where bent up bars are provided, their contribution towards shear resistance shall not be more than 50% of the total shear to be resisted. USE OF SINGEL BENT UP BARS(CRANKED) ARE NOT ALLOWED IN THE CASE OF EARTHQUAKE RESISTANCE STRUCTURES.

Page 11: Reinforcement  detailing

DETAILING OF SLABS WITHOUT ANY CUT OR OPENINGS.

The building plan DX-3 shows the slabs in different levels for the purpose of eliminating the inflow of rainwater into the room from the open terrace and also the sunken slab for toilet in first floor.

The building plan DX-A3 is one in which the client asked the architect to provide opening all round.

Refer the 3d elevation

Page 12: Reinforcement  detailing

Different shapes of slabs used in the buildings. 6”depression for OT &

9” for sunken slabs.

Portico slab in elevation

19’-6”

9’-6”suare opening

5’wide corridor all

round

Portico and other rooms roof slab in plan

Portico slab in plan

Page 13: Reinforcement  detailing

Minimum and max.reinforcement % in beams, slabs and columns as per codal provisions should be followed.

SLABS:

It is better to provide a max spacing of 200mm(8”) for main bars and 250mm(10”) in order to control the crack width and spacing.

A min. of 0.24% shall be used for the roof slabs since it is subjected to higher temperature. Variations than the floor slabs. This is required to take care of temp. differences.

It is advisable to not to use 6mm bars as main bars as this size available in the local market is of inferior not only with respect to size but also the quality since like TATA and SAIL are not producing this size of bar.

BEAMS:

A min. of 0.2% is to be provided for the compression bars in order to take care of the deflection.

Page 14: Reinforcement  detailing

The stirrups shall be min.size of 8mm in the case of lateral load resistance .

The hooks shall be bent to 135 degree .

Page 15: Reinforcement  detailing

Ld/2Ld/2

Ld

crack

INCORRECT

CORRECT

CLOSE STIRRUPS

Ldt

Ldt/2

CANTILEVER BEAM

Page 16: Reinforcement  detailing

NON PRISMATIC BEAM

Ld/2 Ld/2Ld

INCORRECT

CORRECT

CLOSE STIRRUPS

crack

Ldt/2

Ldt

Page 17: Reinforcement  detailing

GRID BEAMGRID BEAM

INCORRECT

1.5d1.5d1.5d

Close rings

Hanger bars

Slope 1:10

2#extra bars

300300

d

CORRECT

Page 18: Reinforcement  detailing

Details of Main & Secondary beams

INCORRECT

1.5d1.5d1.5d

Close rings

Hanger bars

300300

d

CORRECT

Secondary beam

Main beam

Secondary beam

60degree

Main beam

Page 19: Reinforcement  detailing

d

1/4OR 1/5 SPAN

1.5d

CORRECT

INCORRECT

d/2+d/2Cot(t)

tt

Ld

d/2

d/2

LdLINE OF CRACK

BEAM

Page 20: Reinforcement  detailing

Continuous beam• continuous beam Span/4

Span/4Span/4

Span/4

incorrect

Span/4

Span/4

1.5d1.5d

Span/4

correct

1.5d

Page 21: Reinforcement  detailing

100%

L1

100% CRACKCRACK

.08L2.08L1 L2

SPAN/4 SPAN/4

CONTINUOUS BEAM

INCORRECT

.08L1

.08L1

SPAN/4

CRACK

100%

L1

100%

.15L2 L2

L1/4 L2/4

CORRECT

0.1L1

.15L1

L1/4100%

20% 20%

Page 22: Reinforcement  detailing

D

D

CRACK

INCORRECT

NONPRISMATIC SECTION OF BEAM

D

D

DCORRECT

D

CLOSE RING

CLOSE RING

Page 23: Reinforcement  detailing

COLUMNINCORRECT

CANTILEVER BEAM PROJECTING FROM COLUMN

CORRECT

NOT LESS THAN GREATER OF 0.5L OR Ld50mm

0.25Ast

NOT LESS THAN 0.5Ast

COLUMN

Ld

Ld/3

Page 24: Reinforcement  detailing

CRACK

SLOPING BEAM

CORRECT

Ld

Ld

Page 25: Reinforcement  detailing

CRACK CRACK

INCORRECT

HAUNCH BEAMS

CORRECTL/8 TO L/10 L/8 TO

L/10

L

L

Ld Ld

Ld Ld

Page 26: Reinforcement  detailing

STRESSES AT CORNERS

C

C-COMPRESSION

T-TENSION

t

t

C

RESULTANT TENSILE STRESS FOR ACROSS CORNER(ONE PLANE)

t

c

RESULTANT TENSILE STRESS FOR ACROSS CORNER(DIFFERENT PLANE)t

c

CRACK

CRACK

Page 27: Reinforcement  detailing

SHEAR AND TORSION REIN. IN BEAMS

INCORRECT

Min 0.2%bd to control deflection as well as for seismic requ.

b

D100 to 200mm

d

D-n>500mm

D/5

Skin rein.10dia is required when depth exceeds 450mm(0.1% of web area distributed equally on two faces)

Stirrups taken round outermost bars spacing<=x1

<=(x1+y1)/4

<=300mm

x1

y1

D-n>500mm

n

CORRECT

Page 28: Reinforcement  detailing

CANTILEVER BEAM WITH POINT LOAD

CORRECT

INCORRECT

2/3dd

Shear rein.

Extra ties

Ld

Ld

Page 29: Reinforcement  detailing

opening

CORRECT

OPENING IN WEB OF BEAM

crackcrack

openingINCORRECT

OPENING IN WEB OF BEAM

Ld

d/2 d/2

Closed stps for d/2 Closed stps

for d/2

Page 30: Reinforcement  detailing

BEAM COLUMN JUNCTION-EXTERIOR COLUMN

CORRECT

INCORRECT

CLOSED STPS2”max

IN TENSION-Ld

U TYPE BARS

Ld

Page 31: Reinforcement  detailing

CORRECT

SPLICE DETAIL FOR COLUMN

INCORRECT

COVER

CLOSE TIES @S/2

S-SPACING

SLOPE 1:6

Page 32: Reinforcement  detailing

REDUCTION COLUMN BOTH SIDES

INCORRECT

CORRECT

3NO.CLOSE TIES

SPLICE

CLOSE STPS SPACIN <=75mm

SLOPE 1:8 FROM BEAM BOTTOM

3NO.CLOSE TIES

Page 33: Reinforcement  detailing

TERMINATION OF COLUMN BARS INSIDE BEAM

INCORRECT

CORRECT

Ld

Page 34: Reinforcement  detailing

BEAM COL. JUNCTION-EQ REGION

EQ REGION-BEAM-COL JN-EXTERIOR

CORRECT

BEAM COL. JUNCTION-EQ REGION

INCORRECT

END REGION

END REGION

COL.

CORE*

SPACING OF LATERAL TIES <=100mm

SPACING OF LATERAL TIES <=d/2

SPACING OF LATERAL TIES <=d/2

SPACING OF LATERAL TIES <=d/2

*COL.CORE HAS TO BE CONFINED BY CIRCULAR OR RECTANGULAR TIES IN ACCORDANCE WITH END REGION

Page 35: Reinforcement  detailing

COLUMN DETAILS IN EQ REGIONS

END REGION

END REGION

First stirrups 50mm from beam face

Spacing of shear rein. In columns

incorrect

Spacing of shear rein. In columns

correct

END REGION-h/6 or D or 450MM whichever is greater

END REGION

hd

D

b

Page 36: Reinforcement  detailing

EQ-REGION-CONTINUOUS BEAM

INCORRECT

Ld

A=L1/3

CONTINUOUS BARS NOT LESS THAN ¼ AREA OF BARS AT COL.FACE

A=L1/3 A=L1/3

2d

50mmmax

Stirrup spacing=d/4 or 100mm or 8dia which ever is the least

2d2d 2dstp@maxd/2 stp@maxd/2

CORRECT

Page 37: Reinforcement  detailing

INCORRECT

FOOTING-DETAILS(INDEPENDENT)

CORRECT

COVER TO STARTER

STARTER BARS

COLUMN BARS

NATURAL G.L

Ldt

Lb

3” SIDE COVER

Ldt COVER50mm IF p.c.c below or 75mm

Min.300

Page 38: Reinforcement  detailing

TYPICAL REIN DETAILS OF HAMMER FOUNDATION BLOCKINCORRECT

CORRECT

Ld

Ld

Page 39: Reinforcement  detailing

SECTION OF TRENCH

CRACK

INCORRECTINCORRECT

CORRECT

LdLd

Ld

Page 40: Reinforcement  detailing

STAIRCASE-WITH WAIST SLAB

INCORRECT

CORRECT

Ld(min)Extra bar

Ld(min)

Ld(min)

Page 41: Reinforcement  detailing

Main bar

Dist.

Main barAlternate 1

SLABLESS STAIRCASE

Page 42: Reinforcement  detailing

Main bar

Alternate 2

A=0.25L

L=horizontal span

SLABLESS STAIRCASE

Page 43: Reinforcement  detailing

DEVELOPMENT LENGTH OF BARS

SLNO BAR DIA.

TENSIONmm

COMPRESSION REMARKS

1 8 376.0 301.0

2 10 470.0 376.0

3 12 564.0 451.0

4 16 752.0 602.0

5 20 940.0 752.0

6 22 1034.0 827.0

7 25 1175.0 940.0

8 28 1316.0 1053.0

9 32 1504.0 1203.0

FOR A CONCRETE GRADE M20 &STEEL STRENGTH Fy=415

APPROXIMATELY USE 50Xdia FOR TENSION

Page 44: Reinforcement  detailing

CONCLUSION:Before concluding I will show some more details drawn in autocad exported in wwf format

As there is no time to elaborately explaining ,the following topics are not covered :

1. Flat slabs, Folded plates, shell structures-cylindrical shells, silos, 2. Staircases- helical staircase, central beam type, cantilever type etc.3. Different types of foundations-raft, pile foundation, strap foundation etc.4. Retaining wall structures,5. Liquid retaining structures.6. Deep beams.7. Shear wall, walls.

Hope that I have enlighten some of the detailing technique for the most commonly encountered RCC members in buildings.

In the above statements if my senior colleagues and ACCE members can find different method or any new detailing system it will be of immense help not only for me but to other young engineers who should learn in wright ways and not wrong lessons.

Page 45: Reinforcement  detailing

REFERENCES:

1. HANDBOOK ON CONCRETE REINFORCEMENT AND DETAILING-SP:34(S&T)-1987.

2. MANUAL OF ENGINEERING & PLACING DRAWINGS FOR REINFORCED CONCRETE STRUCTURES-

(ACI 315-803. MANUAL OF STANDARD PRACTICE –CONCRETE

REINFORCING STEEL INSTITUTE.4. TWARD BOARD MANUAL FOR RURAL WATER

SUPPLY SCHEMES.5. DESIGN PRINCIPLES AND DETAILING OF CONCRETE

STRUCTURES. By D.S.PRAKASH RAO.6. SIMPLIFIED DESIGN-RC BUILDINGS OF MODERATE

SIZE AND HEIGHT-BY PORTLAND CEMENT ASSOCIATION,USA.

7. DESIGN AND CONSTRUCTION FAILURES BY DOV KAMINETZKY.

Page 46: Reinforcement  detailing

8. IS:2502-1963 CODE OF PRACTICE FOR BENDING AND FIXING OF BARS FOR CONCRETE REINFORCEMENT.

9. IS:1893:2000.

10. IS:4326.

11. IS:456:2000

12. REINFORCED HAND BOOK BY REYNOLD.

Page 47: Reinforcement  detailing