Regulatory changes - PSA

11
PTIL/PSA Regulatory changes - PSA Olav Hauso Senior Adviser Petroleum Safety Authority, Norway (PSA) Norsk Olje og Gass - Subsea Operations - Annual Conference 2013

description

Regulatory changes - PSA. Olav Hauso Senior Adviser Petroleum Safety Authority , Norway (PSA). Regulatory changes - PSA. New regulations from the Labour Inspectorate (Arbeidstilsynet) also applicable for the petroleum activity (from 01.01. 2013)! - PowerPoint PPT Presentation

Transcript of Regulatory changes - PSA

Page 1: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Olav Hauso

Senior Adviser

Petroleum Safety Authority, Norway (PSA)

Page 2: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

New regulations from the Labour Inspectorate (Arbeidstilsynet) also applicable for the petroleum activity (from 01.01. 2013)!

PSA referring to NORSOK U-100 offshore PSA referring to NORSOK U-103 onshore

describing ways to meet the requirements of the regulations.

Page 3: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Hyperbaric evacuation systems

Two independent hyperbaric evacuation units (HEU) on each diving support vessel (DSV)

Grace period of 3 years for existing DSVs Existing DSVs may operate in grace period if HEU is

free to be launched – not restricted by e.g. platform Very pleased with the IMCA initiative on

standardisation of HEU flanges

Page 4: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Depth/time restrictions

Restating the 180 meters «limit» for «normal diving» as the reference for time limits; Working period (14 days/10 days) Bell run (8 hrs/6 hrs) In water time (4-6 hrs/3 hrs) Time between saturations (1X last sat./2X last sat.)

Time limits as stated in the 1991 regulations for Manned Underwater Operations (MOU)

No effect on todays diving (shallower than 180 meters)

Page 5: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Hyperbaric Evacuation Units

Requirements for the boat structure itself as for any other lifeboat (see next slide)

Requirements for the launching arrangements as for any other lifeboat (ref NORSOK R-002)

For design of flanges the IMCA D 051, Hyperbaric Evacuation Systems (HES) Interface Recommendations, should be used

Other references: IMCA D 052 – Guidance on Hyperbaric evacuation systems. Maybe too late to be included this year

Page 6: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Safety level, cf Facilities regs. § 44

Personnel safety: DNV-OS-E406 section 8, pnt B (limits for actions and injury to personnel).

Structural integrity : DNV-OS-E406, section 2 (safety philosophy), section 3 (environmental conditions), section 4 (loads and effects of loads).

Propulsion: DNV-OS-E406, section 7 D203, E103 and E301 – 306, and section 3 environmental conditions

Page 7: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Onshore petroleum facilities

Bell/saturation diving - referring to offshore regulations and standards (NORSOK U-100)

Surface oriented diving as per onshore regulations, (Labour Inspectorate) but – referring to NORSOK U-103 Manned Underwater Operations at inshore

petroleum sites

(more stringent requirements than the inshore regulations specify)

Page 8: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Safety alert number: 248 OGP Safety Alerts http://info.ogp.org.uk/safety/

Corrective Actions and Recommendations:

“Ensure minimum personnel levels for diving are 5.

One supervisor who cannot leave the dive site, a diver, a diver's tender, a standby diver and standby diver's tender. All personnel should be diver qualified and competent.»

Page 9: Regulatory changes  - PSA

PTIL/PSANorsk Olje og Gass - Subsea Operations - Annual Conference 2013

Regulatory changes - PSA

Taking diving far north….

No spesific regulatory elements considered to be changed pt due to geographical area

Present regulations should be adequate, focusing on risk and risk management

May need to reconsider if/when spesific operations should arise

Page 10: Regulatory changes  - PSA

PTIL/PSA

Distances going north..

Page 11: Regulatory changes  - PSA

PTIL/PSA

1600 NM /3000 km