Rectangular & Square Duct Fans

28
75 Rectangular & Square Duct Fans Max. airflow m 3 /s Suitable for mounting Outside Low height Speed Controllable Acoustic Insulation MUB RS RSI KDRE / KDRD KE / KT Access panel for easy Maintenance KVD / KVB / KPB KP DUO Page Number Run & Standby Motors KE 0.81 * * * 76 KT 2.47 * * * 76 RS 3.36 * * * 78 RSI 3.35 * * * * 78 KDRE 3.07 * * 82 KDRD 4.13 * * 82 MUB 5.5 * * * * 84 KVD 1.99 * * * * 88 KVB 2.5 * * * 88 KPB 5.41 * * * 91 KPD DUO 1.94 * * * * * 100 KPB DUO 5.4 * * * * 100

Transcript of Rectangular & Square Duct Fans

Page 1: Rectangular & Square Duct Fans

75

Rectangular & Square Duct Fans

Max

. air

flow

m3 /s

Suita

ble

for

mou

ntin

g O

utsid

e

Low

hei

ght

Spee

d C

ontr

olla

ble

Aco

ustic

Insu

latio

n

MUB

RS

RSIKDRE / KDRD

KE / KT

Acc

ess

pane

l for

eas

y M

aint

enan

ce

KVD / KVB / KPB

KP DUO

Page

Num

ber

Run

& St

andb

y M

otor

sKE 0.81 * * * 76

KT 2.47 * * * 76

RS 3.36 * * * 78

RSI 3.35 * * * * 78

KDRE 3.07 * * 82

KDRD 4.13 * * 82

MUB 5.5 * * * * 84

KVD 1.99 * * * * 88

KVB 2.5 * * * 88

KPB 5.41 * * * 91

KPD DUO 1.94 * * * * * 100

KPB DUO 5.4 * * * * 100

Page 2: Rectangular & Square Duct Fans

Accessories

76

K-Fan

Rectangular & Square Duct Fans

KE / KT - Rectangular Duct Fans

The KE/ KT models have impellers with forward-curved blades and external rotor motors. The motor and impeller are mounted on the access cover to facilitate easy maintenance. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating the fans have integral thermal contacts with external leads for connection to a motor protection device. The fans can be installed in any position and are easy to connect using the DS flexible connections. The KE/KT fans have a pre-wired, integral terminal box. KE is single phase, KT is three phase.

Product

Code

SFP*

(kW/m3/sec)

Voltage Speed

rpmAirflow m3/sec @ Static Pressure Pa. Motor Data dBA @

3m

Speed Control

100 150 200 250 300 400 FLC SC kW

KE40-20-4 0.95 230 1206 0.266 0.241 0.20 0.008 - - 1.0 4.0 0.227 55 RTRE 1.5

KE50-25-4 1.15 230 1298 0.42 0.38 0.34 0.27 - - 2.51 8.0 0.533 55 RTRE 3

KE50-30-4 1.43 230 1193 0.59 0.55 0.52 0.46 0.4 - 3.67 12.4 0.819 59 RTRE 5

KE60-30-4 1.68 230 1342 0.74 0.72 0.66 0.63 0.58 0.40 5.4 18.0 1.231 62 RTRE 7

KT50-25-4 0.95 400 1287 0.48 0.44 0.40 0.33 0.23 - 0.95 3.9 0.55 58 RTRD 2

KT50-30-4 1.21 400 1193 - 0.61 0.57 0.50 0.41 0.10 1.41 4.5 0.80 57 RTRD 2

KT60-30-4 1.2 400 1342 0.88 0.85 0.82 0.76 0.71 0.53 2.36 6.7 1.36 58 RTRD 4

KT60-35-4 1.68 400 1250 - - 1.27 1.22 1.18 1.05 4.12 21.0 2.46 61 RTRD 7

KT70-40-4 1.92 400 1297 - - - - 1.63 1.52 6.04 26.5 3.616 66 RTRD 7

KT70-40-6 0.93 400 805 1.31 1.23 1.15 1.06 0.91 - 3.0 18.2 1.628 57 RTRD 4

KT80-50-6 1.1 400 842 2.03 1.98 1.88 1.75 1.61 1.25 4.91 23.2 2.67 59 RTRD 7

KT80-50-8 0.7 400 552 1.32 1.17 1.0 0.69 - - 2.4 13.7 1.14 59 RTRD 4

KT100-50-6 1.44 400 837 - 2.6 2.5 2.4 2.35 2.2 6.79 27.2 3.81 62 RTRD 7

KT100-50-8 0.89 400 614 2.05 1.91 1.78 1.6 1.32 - 4.67 22.8 2.29 58 RTRD7

KE 40-20-4KE 50-25-4KE 50-30-4KE 60-30-4

1

2

3

4

1 2 3 4

KT 50-25-4

KT 50-30-4KT 60-30-4KT 60-35-4KT 70-40-4

1

23

45

1 2 3

4

5

* measured @ maximum efficiency point

• Swing-out Motor & Impeller for access• Speed-controllable• Integral thermal contacts• Can be installed in any position• Maintenance-free and reliable• KE - 1phase KT - 3phase

RetailSchoolsIndustry

RBPage 201

VBRPage 203

DSPage 220

SRKPage 222

PGKPage 204

DXREPage 205

FFSPage 211

3

KE40-20-4KE50-25-4KE50-30-4KE60-30-4

Page 3: Rectangular & Square Duct Fans

Accessories

77

Rectangular & Square Duct Fans

K-FanKE / KT Fan Dimensions

Product

Code

A c/c B C D E c/c F G H J Weight

Kg

KE40-20-4 240 220 198 502 398 420 440 28 530 12

KE50-25-4 290 270 248 532 498 520 540 30 610 18

KE50-25-4 340 320 298 562 498 520 540 32 695 23

KE60-30-4 340 320 298 642 598 620 640 34 715 34

KT50-25-4 290 270 248 532 498 520 540 64 610 18

KT50-30-4 340 320 298 562 498 520 540 66 695 21

KT60-30-4 340 320 298 642 598 620 640 70 715 31

KT60-35-4 390 370 348 717 598 620 640 95 805 37

KT70-40-4 440 420 398 787 698 720 740 116 900 56

KT70-40-6 440 420 398 787 698 720 740 94 900 42

KT80-50-6 540 520 497 880 798 820 840 97 1080 64

KT80-50-8 540 520 497 880 798 820 840 97 1080 56

KT100-50-6 540 520 497 980 998 1020 1040 97 1130 80

KT100-50-8 540 520 497 980 998 1020 1040 97 1130 80

KE / KT Fan Sound Data

KE40-20-4

KE50-25-4

KE50-25-4

KE60-30-4

KT50-25-4

KT50-30-4

KT60-30-4

KT60-35-4

KT70-40-4

KT70-40-6

KT80-50-6

KT80-50-8

KT100-50-6

KT100-50-8

WIRINGPage 256

RE 1.5Page 229

VKPage 214

LDRPage 207

STL Page 229

RTRDPage 230

EFDPage 222

PRSPage 218

3

Page 4: Rectangular & Square Duct Fans

Accessories

78

K-Fan

Rectangular & Square Duct Fans

RS / RSI - Centrifugal Duct Fan

1

2

3

4

1 2 3 4 12

34

1

2

3

4

1

2

3

4

12 3 4

Product

Code

SFP**

(kW/m3/sec)

Voltage Speed

rpmAirflow m3/sec @ Static Pressure Pa. Motor Data dBA @ 3m Speed Control

100 150 200 250 300 400 FLC kW RS RSI Elec Trans

RS 30-15 0.87 240 2431 0.106 0.088 0.072 0.06 0.033 - 0.26 0.060 48 - STL 1.5 RE 1.5

RS 40-20M 0.97 240 2597 0.180 0.165 0.142 0.113 0.094 0.04 0.46 0.106 52 - STL 1.5 RE 1.5

RS 40-20L 1.11 240 2556 0.300 0.271 0.26 0.24 0.21 0.17 0.93 0.208 53 - STL 1.5 RE 1.5

RS 50-25 0.66 240 1362 0.312 0.264 0.210 0.14 0.025 - 0.6 0.138 46 - STL 1.5 RE 1.5

*RS 60-35M1 0.69 240 1365 0.80 0.74 0.640 0.61 0.50 0.25 1.91 0.401 58 50 STL 3.0 RE 3.0

*RS 60-35M3 0.77 400 1371 0.850 0.790 0.700 0.63 0.520 0.22 0.80 0.399 58 48 - RTRD 2

*RS 60-35L1 1.08 240 1308 1.000 0.900 0.820 0.69 0.650 0.45 2.80 0.626 58 52 STL 5.0 RTRE 3

*RS 60-35L3 1.03 400 1408 1.050 1.000 0.920 0.85 0.770 0.58 1.59 0.665 61 57 - RTRD 2

*RS 70-40L1 0.69 240 1308 1.400 1.300 1.200 1.08 0.980 0.65 2.84 0.623 60 51 STL 5.0 RTRE 3

*RS 70-40L3 0.95 400 1410 1.260 1.190 1.100 1.03 0.930 0.70 1.7 0.704 61 50 - RTRD 2

*RS 80-50M3 1.14 400 1335 1.790 1.680 1.600 1.49 1.400 1.15 1.97 1.089 60 53 - RTRD 4

*RS 80-50L3 1.4 400 1385 2.375 2.290 2.220 2.09 2.000 1.75 3.6 1.893 63 56 - RTRD 7

*RS 100-50L3 1.81 400 1361 3.180 3.050 2.960 2.80 2.750 2.52 5.09 2.962 65 62 - RTRD 7

* Model available as RSI acoustic fan.

The RS & RSI models have impellers with backward-curved blades and external rotor motors. The motor and impeller are mounted on the access cover to facilitate easy maintenance. To protect the motor from overheating the RS & RSI has integral thermal contacts with external leads for connection to a motor protection device. The fan can be installed in any position and is easy to connect using the DS flexible connections. The casing is manufactured from galvanised sheet steel. The RSI models are thermally and acoustically insulated with 50 mm of mineral wool, with perforated sheet steel on the inner surface.* Model available as RSI acoustic fan.

** measured @ maximum efficiency point

• Speed-controllable• Integral thermal contacts• Can be installed in any position• Maintenance-free and reliable• RSI Model with Acoustic InsulationRetailSchoolsIndustry

RBPage 201

VBRPage 203

DSPage 220

SRKPage 222

PGKPage 204

DXREPage 205

FFSPage 211

3

Page 5: Rectangular & Square Duct Fans

Accessories

79

Rectangular & Square Duct Fans

K-FanRS / RSI Fan Sound Data

RSI 60-35M1RSI 60-35M3RSI 60-35L1RSI 60-35L3

1 2

4

3

1 2 3 4

RSI 70-40L1RSI 70-40L3RSI 80-50M3RSI 80-50L3RSI 100-50L3

123

4

5

12 3 4 5

RS 30-15

RS 40-20M

RS 40-20L

RS 60-35L3

RS 70-40L

RS 70-40L3

RS 50-25

RS 80-50M3

RS 60-35M1

RS 80-50L3

RS 60-35M3

RS 100-50L3

RS 60-35L1

WIRINGPage 256

RE 1.5Page 229

VKPage 214

LDRPage 207

STL Page 229

RTRDPage 230

EFDPage 222

PRSPage 218

3

RSI Breakout

Sound power (Lw) dB(A)

Mid frequency band LwA Surrounding

63 125 250 500 1k 2k 4k 8k Tot

RSI 60-35M1 29 47 54 47 47 44 38 29 57

RSI 60-35M3 29 47 50 48 47 45 37 35 55

RSI 60-35L1 40 54 54 52 49 47 43 39 59

RSI 60-35L3 26 56 59 57 52 54 55 48 64

RSI 70-40L3 39 46 51 52 50 48 44 39 57

RSI 80-50M3 40 51 53 53 52 49 49 50 60

RSI 80-50L3 43 56 55 59 54 52 46 46 63

RSI 100-50L3 53 62 61 61 63 61 56 54 69

Breakout surrounding Data for RSI models

Page 6: Rectangular & Square Duct Fans

80

K-Fan

Rectangular & Square Duct Fans

K-FanRS / RSI Fan Dimensions

B Dc/

c F

H

Gc/c E

C

ø10,0 (x8)

A

KI

JL

8,0

RSI A B C D E F G H I J K L M N O kg

60-35M/L 708 492 640.5 391 620 370 598 347.5 55 92.5 640 139.5 99.5 532 597 61

70-40L1/L3 808 542 741 441 720 420 697 397 55.5 92.5 787 201 169.5 532 597 80

80-50M3/L3 908 662 841 541 820 520 797 497 55.5 112.5 882 194 144.5 656 717 107

100-50L3 1108 662 1041 541 1020 520 997 497 55.5 112.5 982 310 244.5 656 717 137

ø10,0 (x8)

Gc/c E

CA

I

Hc/

c F

D B

J

L NM

O

K

~1200

RS A B C D E F G H I J K L kg

30-15 402 217 340 190 320 170 298 148 79 120 230 254 7

40-20 502 267 440 240 420 220 398 198 99 125 311 353 12

50-25 532 317 540 290 520 270 498 248 125 85.5 366 423 17

60-35 717 402 640 390 620 370 598 348 128 145 490 524 35

70-40 787 452 740 440 720 420 698 398 190 215 490 524 43

80-50 882 573 840 541 820 520 798 498 183 190 614 644 68

100-50 982 583 1040 541 1020 520 998 498 299 290 614 644 97

PGK

RB

VBR

SRK

FFK

DS

KE /KT

RS

LDRDS

TYPICAL ACCESSORIES AVAILABLE

RSI

3

Page 7: Rectangular & Square Duct Fans

81

Rectangular & Square Duct Fans

K-FanAccessories

Examples of using the bolt-on accessories to make off the shelf Air Handling Units

Supply AHU with LPHW HeatingKDRD - Square Mixed flow fan FFS - Bag FilterVBK - LPHW Heating batteryAir Volumes up to 2.8m3/s

Supply AHU with Elec HeatingKDRE - Square Mixed flow fan FFS - Bag FilterRBK - Electric Heating batteryAir Volumes up to 2.5m3/s

3

Page 8: Rectangular & Square Duct Fans

Accessories

82

K-Fan

Rectangular & Square Duct Fans

KDRE / KDRD - Square Mixed Flow Fans

Product

Code

SFP*

(kW/m3/s)

Speed

rpm

Airflow m3/sec @ Static Pressure Pa. Motor Data dBA @

3m

Speed Control

50 100 200 300 400 FLC SC kW Elec Trans

KDRE45 0.54 1387 0.882 0.740 0.185 - - 1.55 5.0 0.325 46 STL3.0 RTRE3

KDRE50 0.63 1297 1.310 1.149 0.680 0.120 - 1.94 7.5 0.442 52 STL5.0 RTRE5

KDRE55 0.8 1280 1.810 1.657 1.240 0.666 0.130 4.10 11.0 0.861 51 STL5.0 RTRE5

KDRE65 0.92 1315 2.900 2.710 2.230 1.580 0.885 6.61 16.0 1.501 61 STL10.0 RTRE7

KDRD50 0.63 1397 1.380 1.260 0.890 0.260 0.96 6.0 0.462 54 RTRD2

KDRD55 0.77 1315 1.746 1.610 1.280 0.760 0.140 1.52 7.5 0.789 55 RTRD2

KDRD65 0.91 1341 2.743 2.577 2.140 1.480 0.740 2.23 10.0 1.250 53 RTRD4

KDRD70 1.04 1400 3.960 3.800 3.400 2.930 2.320 4.68 25.0 2.493 62 RTRD7

KDRE/KDRD fans have an external rotor motor with a mixed flow type impeller. The KDRE/KDRD series is notable for its relatively high static pressure and high level of efficiency. The casing is manufactured from galvanised sheet steel. To protect the motor from overheating, the KDRE/KDRD fans have integral thermal contacts with leads for connection to a motor protection device. The fans can be installed in any position and are easy to connect using the DSK flexible connections.

1234

1 2 3 4

1

234

1 2 3 4

* measured @ maximum efficiency point

• KDRE Fan - single phase. 230V - 1Ph - 50Hz• KDRD Fan - three phase. 400V - 3Ph - 50Hz• Speed-controllable• Integral thermal contacts• Can be installed in any positions• Maintenance-free and reliable

Industry Retail Schools

SRKGPage 222

DSKPage 220

RBKPage 202

LDKPage 206

FFKPage 213

VBKPage 202

3

Page 9: Rectangular & Square Duct Fans

Accessories

83

Rectangular & Square Duct Fans

K-FanKDRE / KDRD Fan Dimensions

KDRE/KDRD A B C D kg

KDRE 45 447 470 492 400 26

KDRE/KDRD 50 502 520 547 450 41

KDRE/KDRD 55 550 573 595 485 42

KDRE/KDRD 65 661 680 707 510 54

KDRD 70 696 720 740 530 62

ø10(4x)

45

A *c/cB

C

KDRE / KDRD Fan Sound Data

KDRE 50

KDRE 45

KDRE 55

KDRE 65

KDRD 50

KDRD 55

KDRD 65

KDRD 70

WIRINGPage 256

WSGPage 216

RTREPage 229

PRSPage 218

STL Page 229

S-ETPage 230

RTRDPage 230

3

Page 10: Rectangular & Square Duct Fans

Accessories

84

K-Fan

Rectangular & Square Duct Fans

MUB - Multibox Centrifugal fan

In-line discharge

to 90°

The MUB fans have impellers with backward curved blades, manufactured from aluminium except the 355 which ispolyamide. The MUB is equipped with external rotor motors or IEC standard motors, fully speed controllable. The three phase motors are D/Y connected for two speed operation. Motor protection is done by thermal contacts, which have to be connected to an external motor protection device. The casing consists of a corrosion-resistant aluminium frame with fibreglass reinforced plastic corners of PA6; highly shock-resistant. The double skin panels are manufactured from galvanised steel with 20 mm mineral wool insulation. To avoid condensation the profile is provided with a separate chamber to fix screws. The Multibox fans are delivered for straight through airflow but can easily be rebuilt due to removable panels. This allows flexible ventilation solutions. The MUB can also be used as extract or supply air unit in air handling units. Installation in any mounting position is possible. (* Power at Shaft)

Product Code SFP**

(kW/m3/s)

Airflow-

Straight

Speed

RPM

Airflow m3/sec @ Static Pressure Pa. Motor Data dBA

@

3m

Speed Control

Airflow 90º100 200 300 400 500 FLC kW Elec Trans

Single Phase Standard

MUB 025 355E4-A2 0.65 Straight 1260 0.551 0.43 0.096 - - 1.05 0.25 55 STL 1.5 RTRE 1.5

0.64 90º 0.636 0.50 0.288

MUB 042 400E4-A2 0.75 Straight 1360 0.92 0.80 0.64 0.26 - 2.2 0.373 49 STL 3.0 RTRE 3

0.83 90º 0.89 0.77 0.63 0.37

MUB 042 450E4-A2 0.99 Straight 1280 1.236 1.05 0.852 0.56 - 2.8 0.640 52 STL 5.0 RTRE 5

0.92 90º 1.32 1.10 0.912 0.68 -

MUB 042 499E4-A2 1.19 Straight 1320 1.50 1.306 1.09 0.85 0.482 4.95 1.10 48 STL 10.0 RTRE 5

1.09 90º 1.65 1.446 1.235 1.01 0.72

MUB 042 500E4-A2 1.15 Straight 1340 1.73 1.57 1.38 1.16 0.85 4.80 1.080 56 STL 10.0 RTRE 7

1.21 90º 1.958 1.748 1.54 1.32 1.107

Three Phase Standard

MUB 025 355DV-A2 0.68 Straight 1300 0.52 0.38 - - - 0.58 0.207 55 RTRD2

0.6 90º 0.606 0.469 0.11 - -

MUB 042 400DV-A2 0.69 Straight 1340 0.906 0.771 0.59 0.09 - 0.7 0.305 49 RTRD2

0.66 90º 0.96 0.80 0.605 0.22 -

MUB 042 450DV-A2 0.84 Straight 1230 1.246 1.085 0.893 0.595 - 1.3 0.69 52 RTRD2

0.87 90º 1.375 1.178 0.973 0.753 0.184

MUB 042 499DV-A2 0.97 Straight 1200 1.408 1.216 0.998 0.694 0.199 1.8 0.9 48 RTRD2

1.65 90º 1.548 1.316 1.084 0.812 0.453

MUB 042 500DV-A2 1.18 Straight 1330 1.843 1.686 1.529 1.329 1.054 4.3 1.5* 56 RTRD7

1.26 90º 1.983 1.779 1.585 1.415 1.219

MUB 062 560DV-A2 1.32 Straight 1420 2.763 2.571 2.38 2.197 2.02 5.8 2.2* 57 RTRD7

1.37 90º 3.048 2.8 2.51 2.28 2.048

MUB 062 630DV-B2 1.72 Straight 1340 3.514 3.341 3.172 3.000 2.776 9.2 3.42 69 RTRD14

1.69 90º 3.958 3.764 3.563 3.368 3.177

MUB 062 630D4-A2 1.8 Straight 1400 3.781 3.632 3.48 3.312 3.129 9.5 4.0* 69 Inverter

1.73 90º 4.316 4.137 4.000 3.772 3.584

MUB 100 630D4-L 1.84 Straight 1435 4.9 4.7 4.6 4.3 4.1 9.5 5.5 75 Inverter

1.73 90º 5.5 5.2 5.1 4.8 4.6

MUB 100 710D6-A2 0.99 Straight 954 3.8 3.5 3.2 2.7 2.1 5.16 2.46 60 RTRD7

0.98 90º 4.1 3.8 3.4 3.0 2.5

• Speed-controllable• Modular system (Penta-post construction)• Integral thermal contacts• Low sound level - Double Skin (Acoustic Insulated)• Flexible airflow direction due to removable panels • Installation in any mounting position• High temp Kitchen version & EC motor available

FGVPage 220

UGSPage 220

SRKGPage 222

WSDPage 218

MUB-SILPage 207

PRSPage 218

STL Page 229

RTRDPage 230

3

Page 11: Rectangular & Square Duct Fans

85

Rectangular & Square Duct Fans

K-FanMUB Fan Performance Curves

Airflow Straight ThroughMultibox Fan as per arrows

Airflow at 90º sideDischarge as per arrows

3

Page 12: Rectangular & Square Duct Fans

Accessories

86

K-Fan

Rectangular & Square Duct Fans

K-FanMUB Fan Dimensions

MUB Asq Bsq Csq øD øE kg

025 355 -A2 500 420 378 355 224 37

042 400 -A2 670 590 548 400 253 58

042 450 -A2 670 590 548 454 286 54

042 499 -A2 670 590 548 504 321 66

042 500 -A2 670 590 548 504 321 68

062 560 -A2 800 720 676 570 361 130

062 630 -B2 800 720 678 635 407 145

062 630 -A2 800 720 678 635 407 135

100 630 D4-L 1000 920 878 630 389 160

100 710 -A2 1000 920 878 715 460 160

MUB Changing of air flow direction

FGV

TYPICAL ACCESSORIES AVAILABLE

WSG

SRKG

UGS

MUB

WSD

SRKG

UGS

FGV

UGSPage 220

SRKGPage 222

WSDPage 218

MUB-SILPage 207

PRSPage 218

STL Page 229

WSGPage 216

RTRDPage 230

3øEøD�C

�B�A

�A

Page 13: Rectangular & Square Duct Fans

87

Rectangular & Square Duct Fans

K-FanMultibox AHU

Filter sectionPanel FiltersBag Filters

Carbon Filters

Cooling Coil sectionChilled Water

DX Coil

Heating Coil sectionLPHW BatteryElectric Battery

Mixing Box section Heat Recovery section

Multibox Fan sectionShowing Louvre outlet& pre wired motor to

external isolator

Multibox Air Handling UnitsThe Multibox can be used as a standard extract fan or you can build your own air handling unit

with the components below. Units can be either supplied in sections or built in one piece.Please enquire for technical selections

Multibox AHU

3

Control Panels

7

Multibox „MUB“

• Im Gehäuse eingebautes, frei-laufendes Motorlüfterrad aus Aluminium

• Einseitig saugend, rückwärts gekrümmte Laufradschaufeln

• Direktantrieb mit innenliegen-dem Außenläufermotor, 0 - 100 %, elektronisch und trans-formatorisch steuerbar

• IEC-Standard-Normmotor bzw. spannungssteuerbarer Norm-motor

Motor und Laufrad sind statisch und dynamisch ausgewuchtet (Q=6,3 nach VDI 2060). Es ist ein Motorschutz über Thermo-kontakte bzw. über Kaltleiter möglich. Die Motor-Laufradein-heit wird auf einer Konsole aus verzinktem Stahlblech und Be-festigungsschienen im Gehäuse befestigt. Die Einströmung er-folgt über ein Einlassblech mit integrierter, tiefgezogener Ein-strömdüse.

• Singleplug lers, i

• Direct motor, 0 - lable, eformers

• IEC standard mototor speed contro

• The unit is mainpre-wired to a

The motor and anced together ynamically (Q= VDI 2060). The protected by ther cold conductors. The motor impeller is fixed on a mounting bracket and mount-ing rails inside the casing which is manufactured from galvanised steel. The air inlet is through an inlet panel with integrated inlet cone.

WRG

Als preiswerte Lösung zur Rege-lung und Steuerung von einfachen Standardlüftungsanlagen wurde die Schaltschrankreihe “Syste-matic F/K” entwickelt.

Grundausführung:• 5-stufige Drehzahlsteuerung für

die Ventilatoren• Pumpensteuerung für den Er-

hitzer• Frostschutzschaltung• Klappensteuerung• Temperaturregelung, stetig auf

Erhitzerventil wirkend• ZentralentriegelungWeiteres Zubehör und Einbautei-le auf Anfrage.

Our newly developed controller „Systematic F/K“ is an easy and competitive solution for control-ling standard air handling units.

Basic model:• 5-step transformer to control

the fan speed• Contolling the pump for the wa-

ter heating battery• Frost protection• Damper regulation• Temperature regulation control-

ling to the valve of the heating battery

• Central unlockingOther accessories and compo-nents on request.

Regelungs und Steuerung „Systematic F/K“ /Control panel „Systematic F/K“

Page 14: Rectangular & Square Duct Fans

88

K-Fan

Rectangular & Square Duct Fans

KVD / KVB - Single Box Fans

KVD (direct driven) and KVB (belt driven) from sizes 7/7 to 12/12 are a range of single skin supply or extract box fans for inline application. These fans are designed for cost effective installations with low to medium pressure drop whilst keeping very good sound performances.

Features & benefitsRobust and quiet operation thanks to the galvanized steel fan and motor support mounted on 4 anti-vibration rubber plots. Outlet connected to the casing through an 18 mm thick rubber joint acting as a flexible seal.

Reinforced bottom panel giving the box fan more stability and mechanical resistance. Indoor and outdoor installation with the same standard unit. Easy to install with motor wired to the IP 55 connection box. KVB and KVD have a round inlet and square outlet.Efficient double inlet galvanized steel forward curved impeller balanced statically and dynamically. The KVB and KVD have a 3 year warranty. Airflows up to 50 000 m3/h are available upon request. Operates with air up to 50°C.

Belt driven KVB range is available for three phase 60 Hz operation.

AncillariesOutlet rain hood with bird net, ORHIntake silencer, LDCFast clamp, FKBack draft damper, RSKMaintenance switch, REVPressure switchAnti-vibration mounts

• KVD – Double inlet Direct Driven range with airflows from 700 to 7,500 m3/h. (0.2m3/s to 2.08m3/s)• IP 54 Class Motors single phase except 12-12-D6 3phase.• KVB – Double inlet belt driven range with airflows from 700 to 13,000 m3/h (0.2m3/s to 3.60m3/s)• IP 55 Class F motors.• Casing in galvanized steel with standard roof and feet for

outdoor installation

RetailHospitalsIndustry

3

Page 15: Rectangular & Square Duct Fans

89

Rectangular & Square Duct Fans

K-FanKVD / KVB Double Inlet Box Fans Technical Data

KVB Belt driven IEC Motor IP 55 F Class

Motor kW Max V Hz Motor Wiring Wiring Weight (kg)

kW Amp

Min - Max m3/h r.p.m 1 speed 2 speed Min - Max

7/7 0.25 - 0.55 2800 400 50/60 1450 13a 14a 32 - 37 0.25 0.8

9/7 0.25 - 1.1 4100 400 50/60 1450 13a 14a 44 - 52 0.37 1.1

9/9 0.25 - 1.1 4500 400 50/60 1450 13a 14a 45 - 53 0.55 1.5

10/8 0.25 - 1.5 5100 400 50/60 1450 13a 14a 50 - 59 0.75 1.9

10/10 0.25 - 1.5 6200 400 50/60 1450 13a 14a 54 - 60 1.1 2.6

12/9 0.25 - 2.2 6800 400 50/60 1450 13a 14a 71 - 87 1.5 3.5

12/12 0.25 - 2.2 9000 400 50/60 1450 13a 14a 73 - 89 2.2 4.9

KVD Direct driven

SizeWatts Max m3/h Amps

(max m3/h)V/Hz r.p.m max IP Wiring

diagramLpa 1m Weight

(kg)

7-7-E4 (146 W) 146 1700 2.2 230/50 1410 54 1 58 20

7-7-E6 (73W) 73 1685 1.1 230/50 880 54 1 54 20

9-7-E4 (373W) 370 2750 4 230/50 1410 54 1 61 30

9-7-E6 (237 W) 237 2510 2.5 230/50 950 54 1 59 30

9-9-E4 (550 W) 550 3150 5.9 230/50 1450 54 1 64 32

9-9-E6 (237 W) 237 2590 2.4 230/50 950 54 1 61 31

10-8-E6 (237 W) 237 2550 3 230/50 950 54 1 63 35

10-10-E4 (550W) 550 3250 6 230/50 1425 54 1 66 37

10-10-E6 (237W) 237 2700 3.1 230/50 950 54 1 63 36

10-10-E6 (550W) 525 4825 5.7 230/50 950 54 1 65 42

12-9-E6 (736W) 736 4820 8.5 230/50 950 54 1 62 50

12-12-E6 (525W) 525 4400 6.4 230/50 950 54 1 64 50

12-12-E6 (736W) 736 5750 9.8 230/50 910 54 1 67 52

12-12-D6 (1380W) 1380 7150 5.1 400/50 925 54 13a 71 52

Gre

en/y

ello

w

Blac

k

Deltaconnection

Starconnection

Wiring 1. 230V Single speed

Wiring 13a.400V Single speed

Blue

Electrical wiring

Wiring 14a.400V Two speed

3

Quick Selection Tabulated Tables on page 98 & 99

Page 16: Rectangular & Square Duct Fans

90

K-Fan

Rectangular & Square Duct Fans

K-FanKVD / KVB Double Inlet Box Fans Dimensions

KVD Direct driven single skin

A A’ A’’ B B’ C D E øF

7-7 498 458 454 457 415 442 273 253 200

9-7 548 508 504 507 465 532 336 304 250

9-9 548 508 504 507 465 532 336 304 250

10-8 648 608 604 607 565 592 371 330 300

10-10 648 608 604 607 565 592 371 330 300

12-9 698 658 654 657 615 642 434 382 350

12-12 698 658 654 657 615 642 434 382 350

A''

A

A'

FE

KVB Belt driven single skin

A A’ A’’ B B’ C D E øF

7-7 598 558 555 457 412 441 273 253 250

9-7 748 708 705 562 512 541 336 304 300

9-9 748 708 705 562 512 541 336 304 300

10-8 798 758 755 657 612 591 371 330 350

10-10 798 758 755 657 612 591 371 330 350

12-9 948 908 905 812 762 691 434 382 400

12-12 948 908 905 812 762 691 434 382 400

B'

øF

B

D

C

All dimensions in mm

3

Page 17: Rectangular & Square Duct Fans

91

Rectangular & Square Duct Fans

K-FanKPB - Double Inlet Forward Curved Fan

The KPB from size 15/11 to 18/18 are a range of supply or extract box fan for inline or 90° application. The casing is made of an aluminum frame with single skin or double skin galvanized steel panels. These fans are designed for indoor and outdoor installations with low to medium pressure drop whilst keeping very good sound per-formances.

Features & benefitsRobust and quiet operation thanks to the galvanized steel fan and motor support mounted on 4 anti-vibration rubber plots.

Low noise level: Anti-vibration rubber adjustable feet are fitted below the fan casing. Outlet connected to the casing

through an 18 mm thick rubber joint acting as a flexible seal.Quality casing with aluminum profile structure, plastic corners, M1 fire rated 15 mm isolation through polyurethane foam.Easy access: A maintenance access door on the side is fitted with polyamide hinges and ¼ turn lock and key.Easy to install with motor wired to the IP 55 connection box.Efficient double inlet galvanized steel forward curved impeller balanced statically and dynamically. Inlet panel of KPB is to be ordered withrectangular inlet, damper or closed. The outlet is square. The KPB have a 2 year warranty.

On request, the KPB are available with:- PVC Coating for sea-side location- Double skin panels- EU4 Filter guided through rails for

easy maintenance and fitted inside the casing (with pressure sensor as an option).

AncillariesOutlet/inlet rain hood with net, ORH/IRHEU4 Filter Weather roof, WSDMaintenance switch, REVDamper (manual/motorized)Pressure switchSpecial executionsTwin fans 60 Hz three phase

• KPB – Double inlet belt driven range with airflows from 10,000 to 19,500 m3/h (2.77m3/s to 5.41m3/s)• IP 55 F Class IEC motors (380 V 50 and 60 Hz).• Suitable for operating temps of up to 50°C.• Casing with aluminium profile 15 mm polyurethane foam isolation• Suitable for mounting Outside.

RetailHospitalsIndustry

3

Page 18: Rectangular & Square Duct Fans

Deltaconnection

Starconnection

Wiring 13a.400V Single speed

92

K-Fan

Rectangular & Square Duct Fans

KPB Double Inlet Forward Curved Fan Technical Data

KPB Belt driven Inlet options

KPB Belt driven Manual damper Rectangular inlet

A B C D E F L Length H Height L Length H Height

DA 15-11 1000 950 800 508 443 128 800 672 890 740

DA 15-15 1000 950 800 508 443 128 800 672 890 740

DA 18-13 1150 1100 1000 594 518 120 900 800 1000 900

DA 18-18 1150 1100 1000 594 518 120 900 800 1000 900

Dimensions

Wiring diagram

B

D

A

EF

C

IEC Motor IP55 F Class

1 speed 2 speeds

kW Amp kW

4/8 poles

0.25 0.8 –

0.37 1.1 –

0.55 1.5 0.55/0.09

0.75 1.9 0.75/0.12

1.1 2.6 1.1/0.18

1.5 3.5 1.5/0.25

2.2 4.9 2.2/0.37

3 6.7 3/0.55

4 8.4 4/0.75

5.5 11.3 5.5/1.1

7.5 14.8 7.5/1.5

KPB Belt driven

Motor kW

Max m3/h V Hz Motor r.p.m.

Weight (kg)

Min - Max Min - Max

15/11 0.25 - 3 9500 400 50/60 1450 98 - 122

15/15 0.25 - 3 12800 400 50/60 1450 112 - 136

18/13 0.25 - 7.5 15500 400 50/60 1450 130 - 180

18/18 0.25 - 7.5 19500 400 50/60 1450 139 - 189

All dimensions in mm

Wiring 14a.400V Two speed

ORH, outlet rain hood with bird netIRH, inlet rain hood with bird net

Filter

3

Page 19: Rectangular & Square Duct Fans

93

Rectangular & Square Duct Fans

K-FanKVD / KPD DUO Direct Drive Performance Curves

Quick Selection Tabulated Tables on page 98 & 99

3

Page 20: Rectangular & Square Duct Fans

94

K-Fan

Rectangular & Square Duct Fans

KVD / KPD DUO Direct Drive Performance Curves

E6 (237W)

E6 (237W)

E6 (525W)

E6 (525W)

E6 (525W)

E6 (525W)

E6 (736W)

E6 (736W)

D6

D6

E6

E6

Do not select dotted area

Quick Selection Tabulated Tables on page 98 & 99

3

D6

E6 (736W)

E6 (525W)

Page 21: Rectangular & Square Duct Fans

95

Rectangular & Square Duct Fans

K-FanKVB / KPB DUO Belt Driven Fan Performance Curves

10

20

30

40

50

60

150140130120110100

90

80

70

70504030201054321pd (mm H O)2

C (m/s)2 302015105432

310046%

η50% 49%

45%

39%

800

1000

1200

1400

1600

1800

2000

2200

2400

2800

500 000500040003000200510001052V(m /h)3

7-7

10

20

30

40

50

60

150140130120110100

90

80

70

70504030201054321pd (mm H O)2

C (m/s)2 30 402015105432

60% 67% 70% 69% 63%53%

600

700

800

900

1000

1100

1200

1300

1400

1500

1600

1800

2000

2400

1000 1500 0000100080006000400030002005V(m /h)3

η

9-9

10

20

30

40

50

60

150140130120110100

90

80

70

70504030201054321pd (mm H O)2

C (m/s) 4030201510543

2000

2400

59%65% 67% 65% 60%

51%

700

600

800

900

1000

1100

1200

1300

1400

1600

1800

1000 1500 0000100080006000400030002005V(m /h)3

η

9-7

10

20

30

40

50

60

150140130120110100

90

80

70

70504030201054321pd (mm H O)2

C (m/s) 30 402015105432

60%66%

69%68%

62%

52%

600

700

800

900

1000

1100

1200

1300

1400

1700

1800

2200

1600

1500

1000 1500 0000100080006000400030002005V(m /h)3

η

10-8

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

10 = 100Pa40 = 400Pa100 = 1000Pa

3

To select duty:- Plot airflow in m3/hr, then read bottom table to get Dynamic pressure, which needs to be added onto your design static pressure to give Total pressure. Read off the RPM speed at which the fan will need to run and select the required motor size (move up to the nearest size as specified in previous pages i.e 0.25 0.37 0.55 etc. Typical fan Reference - KPB 9-9/0.37/1000 Please note that Resistance pressure is in mmH20 which x10 = Pa i.e 10mmH20 = 100Pa

Page 22: Rectangular & Square Duct Fans

96

K-Fan

Rectangular & Square Duct Fans

KVB / KPB DUO Belt Driven Performance Curves

10

20

30

40

50

60

150140130120110100

90

80

70

70504030201054321pd (mm H O)2

C (m/s)2 302015105432

60%64%

65%62% 56%

47%

600

700

800

900

1000

1100

1200

1400

1500

1600

1300

1700

1800

2200

1000 1500 0000100080006000400030002005V(m /h)3

η

10-10

10

20

30

40

50

60

150140130120110100

90

80

70

65%69%

68% 60%

500

600

700

800

900

1000

1100

1200

1300

1400

1500

1800

70504030201054321pd (mm H O)2

C (m/s)2 30 402015105432000 30001000 1500 4000 6000 8000 10000 15000 20000V(m /h)3

η

12-12

10

20

30

40

50

60

150140130120110100

90

80

70

72%

74%73% 67%

56%

800

700

600

500

900

1000

1100

1200

1300

1400

1600

1800

70504030201054321pd (mm H O)2

C (m/s)2 30 402015105431500 2000 000410000100080006000400030001057V(m /h)3

η

12-9

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

10 = 100Pa40 = 400Pa100 = 1000Pa

Quick Selection Tabulated Tables on page 98 & 99

3

Page 23: Rectangular & Square Duct Fans

97

Rectangular & Square Duct Fans

K-FanKPB / KPB DUO Belt Driven Performance Curves

10

20

30

40

50

60

150140130120110100

90

80

70

58%64% 65%

62% 54%

400

500

600

700

800

900

1000

1100

1200

1400

70504030201054321pd (mm H O)2

C (m/s)2 30 402015105433000 4000 000030000200051000010008000600020051V(m /h)3

η

15-15

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

40002000 3000 8000 1500010000 0000400003000020006

10

20

30

40

50

60

150140130120110100

90

80

70

73%70% 63%

52%

300

350

400

450

500

600

700

800

900

1000

1200

70504030201054321pd (mm H O)2

C (m/s) 30 40201510543V(m /h)3

η

18-13

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

40002000 3000 8000 1500010000 0000400003000020006

10

20

30

40

50

60

150140130120110100

90

80

70

70%73%

71%64%

350

400

450

500

600

700

800

900

1000

1200

70504030201054321pd (mm H O)2

C (m/s)2 30 40201510543V(m /h)3

η

18-18

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

10

20

30

40

50

60

150140130120110100

90

80

70

64% 66%

64% 58%

400

500

600

700

800

900

1000

1100

1200

1400

70504030201054321pd (mm H O)2

C (m/s) 30 4020151054322000 30001000 1500 4000 6000 8000 10000 15000 20000V(m /h)3

η

15-11

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

10 = 100Pa40 = 400Pa100 = 1000Pa

10 = 100Pa40 = 400Pa100 = 1000Pa

3

NOT USABLENOT RECOMMENDEDNOT RECOMMENDED

Page 24: Rectangular & Square Duct Fans

98

KVD Direct drivenKPD DUO Twin Fan

Motor Speed Airflow m3/sec @ Static Pressure Pa. Speed Control

Auto Changeover

Panel DUO FanSize

Watts r.p.m max 50Pa 100Pa 150Pa 200Pa 250Pa 300Pa Trans

7-7-E4 (146 W) 146 1410 0.456 0.435 0.416 0.374 - - RTRE3.0 ACO8A

7-7-E6 (73W) 73 880 0.415 - - - - - RTRE1.5 ACO8A

9-7-E4 (373W) 370 1410 0.83 0.82 0.795 0.77 0.73 0.70 RTRE5.0 ACO8A

9-7-E6 (237 W) 237 950 0.66 0.60 0.53 RTRE3.0 ACO8A

9-9-E4 (550 W) 550 1450 1.00 0.97 0.95 0.92 0.85 0.80 RTRE7.0 ACO8A

9-9-E6 (237 W) 237 950 0.65 0.63 0.57 - - - RTRE3.0 ACO8A

10-8-E6 (237 W) 237 950 0.67 0.64 0.60 0.53 - - RTRE5.0 ACO8A

10-10-E4 (550W) 550 1425 1.00 0.97 0.95 0.92 0.90 0.85 RTRE7.0 ACO8A

10-10-E6 (237W) 237 950 0.72 0.66 0.60 0.48 - - RTRE5.0 ACO8A

10-10-E6 (550W) 525 950 1.25 1.15 1.05 0.86 - - RTRE7.0 ACO8A

12-9-E6 (736W) 736 950 1.31 1.27 1.24 1.18 1.10 0.96 RTRE12.0 ACO8A

12-12-E6 (525W) 525 950 1.18 1.16 1.13 1.07 0.95 - RTRE7.0 ACO8A

12-12-E6 (736W) 736 910 1.55 1.50 1.44 1.34 1.20 - RTRE12.0 ACO8A

12-12-D6 (1380W) 1380 925 1.90 1.80 1.70 1.60 1.47 - RTRD7.0 ACO/TO/ADS/3

Rectangular & Square Duct Fans

Quick Selection Data

Fan Ref Airflow m3/sec @ TOTAL Pressure Pa. Motor Data 400V - 50Hz - 3Ph

KVB, KPB Single Fan

KPB DUO Twin Fan

200 300 400 500 600 700 800 900 kW Amps ACOPKPB DUO Fan

KVB 7-7 KPB DUO 7-7 0.52 0.40 0.25 - - - - - 0.37 1.1 ACO/TO/ADS/3

0.69 0.56 0.45 0.30 - - - - 0.55 1.5 ACO/TO/ADS/3

- 0.75 0.64 0.55 0.43 - - - 0.75 1.9 ACO/TO/ADS/3

KVB 9-7 KPB DUO 9-7 0.66 0.53 0.38 - - - - - 0.37 1.1 ACO/TO/ADS/3

0.83 0.72 0.58 0.45 - - - - 0.55 1.5 ACO/TO/ADS/3

- 0.90 0.83 0.72 0.61 - - - 0.75 1.9 ACO/TO/ADS/3

- 1.04 1.00 0.93 0.83 0.72 - - 1.1 2.6 ACO/TO/ADS/3

- - - - - 1.00 - - 1.5 3.5 ACO/TO/ADS/3

KVB 9-9 KPB DUO 9-9 0.75 0.58 0.34 - - - - - 0.37 1.1 ACO/TO/ADS/3

0.94 0.83 0.66 0.45 - - - - 0.55 1.5 ACO/TO/ADS/3

1.16 1.02 0.92 0.78 0.61 - - - 0.75 1.9 ACO/TO/ADS/3

- 1.25 1.14 1.00 0.88 0.77 - - 1.1 2.6 ACO/TO/ADS/3

- - - - 1.20 1.11 - - 1.5 3.5 ACO/TO/ADS/3

KVB 10-8 KPB DUO 10-8 0.75 0.52 - - - - - - 0.37 1,1 ACO/TO/ADS/3

0.97 0.80 0.61 - - - - - 0.55 1.5 ACO/TO/ADS/3

1.16 1.05 0.90 0.75 0.52 - - - 0.75 1.9 ACO/TO/ADS/3

- 1.25 1.13 1.02 0.83 0.67 - - 1.1 2,6 ACO/TO/ADS/3

- - - - 1.25 1.11 0.94 - 1.5 3.5 ACO/TO/ADS/3

- - - - - 1.38 1.30 - 2.2 4.9 ACO/TO/ADS/3

KVB 10-10 KPB DUO 10-10 0.75 0.50 - - - - - - 0.37 1.1 ACO/TO/ADS/3

1.00 0.77 0.58 0.40 - - - - 0.55 1.5 ACO/TO/ADS/3

1.25 1.02 0.89 0.72 0.55 - - - 0.75 1.9 ACO/TO/ADS/3

1.38 1.27 1.11 0.97 0.78 0.64 - - 1.1 2.6 ACO/TO/ADS/3

- 1.61 1.41 1.30 1.16 1.00 0.88 - 1.5 3.5 ACO/TO/ADS/3

- - - - 1.50 1.38 1.25 - 2.2 4.9 ACO/TO/ADS/3

KVB 12-9 KPB DUO 12-9 0.86 0.55 - - - - - - 0.37 1.1 ACO/TO/ADS/3

1.14 0.88 0.61 - - - - - 0.55 1.5 ACO/TO/ADS/3

1.44 1.25 1.04 0.75 - - - - 0.75 1.9 ACO/TO/ADS/3

1.66 1.47 1.27 1.02 0.86 - - - 1.1 2.6 ACO/TO/ADS/3

- 1.80 1.66 1.52 1.33 1.11 - - 1.5 3.5 ACO/TO/ADS/3

- - - 1.83 1.70 1.55 1.38 - 2.2 4.9 ACO/TO/ADS/3

3

Page 25: Rectangular & Square Duct Fans

99

Fan Ref Airflow m3/sec @ TOTAL Pressure Pa. Motor Data 400V-50Hz-3Ph

KVB, KPB Single Fan

KPB DUO Twin Fan

200 300 400 500 600 700 800 900 kW Amps ACOPKPB DUO

KVB 12-12 KPB DUO 12-12 0.75 - - - - - - - 0.37 1.1 ACO/TO/ADS/3

1.16 0.66 - - - - - - 0.55 1.5 ACO/TO/ADS/3

1.52 1.20 0.76 - - - - - 0.75 1.9 ACO/TO/ADS/3

1.72 1.52 1.16 - - - - - 1.1 2.6 ACO/TO/ADS/3

- 1.94 1.69 1.40 1.00 - - - 1.5 3.5 ACO/TO/ADS/3

- 2.30 2.17 1.97 1.73 1.41 - - 2,2 4.9 ACO/TO/ADS/3

- - - - 2.36 2.20 1.94 - 3.0 6.7 ACO/TO/ADS/3

KPB 15-11 KPB DUO 15-11 0.78 - - - - - - - 0.37 1.1 ACO/TO/ADS/3

1.11 0.75 - - - - - - 0.55 1.5 ACO/TO/ADS/3

1.44 1.16 0.86 - - - - - 0.75 1.9 ACO/TO/ADS/3

1.77 1.45 1.16 0.94 - - - - 1.1 2.6 ACO/TO/ADS/3

- 1.92 1.66 1.44 - - - - 1.5 3.5 ACO/TO/ADS/3

- - 2.10 1.88 1.66 - - - 2.2 4.9 ACO/TO/ADS/3

- - - 2.38 2.22 - - - 3.0 6.7 ACO/TO/ADS/3

KPB 15-15 KPB DUO 15-15 1.11 - - - - - - - 0.55 1.5 ACO/TO/ADS/3

1.74 1.05 - - - - - - 0.75 1.9 ACO/TO/ADS/3

2.08 1.52 - - - - - - 1.1 2.6 ACO/TO/ADS/3

2.52 2.22 1.69 - - - - - 1.5 3.5 ACO/TO/ADS/3

3.00 2.77 2.47 1.96 1.45 - - - 2.2 4.9 ACO/TO/ADS/3

- - 3.11 2.83 2.43 1.94 - - 3.0 6.7 ACO/TO/ADS/3

- - - - 3.27 2.91 2.52 - 4.0 8.4 ACO/TO/ADS/3

- - - - - - - 3.11 5.5 11.3 ACP/SD/ADS/3

KPB 18-13 KPB DUO 18-13 1.27 - - - - - - - 0.55 1.5 ACO/TO/ADS/3

1.86 1.30 - - - - - - 0.75 1.9 ACO/TO/ADS/3

2.22 1.75 - - - - - - 1.1 2.6 ACO/TO/ADS/3

2.91 2.44 1.94 - - - - - 1.5 3.5 ACO/TO/ADS/3

3.36 3.02 2.61 2.22 - - - - 2.2 4.9 ACO/TO/ADS/3

- 3.52 3.33 3.05 2.63 2.30 - - 3.0 6.7 ACO/TO/ADS/3

- - - - 3.47 3.13 2.80 2.50 4.0 8.4 ACO/TO/ADS/3

- - - - - - 3.61 3.33 5.5 11.3 ACP/SD/ADS/3

KPB 18-18 KPB DUO 18-18 1.88 - - - - - - - 0.75 1.9 ACO/TO/ADS/3

2.50 - - - - - - - 1.1 2.6 ACO/TO/ADS/3

3.33 2.50 - - - - - - 1.5 3.5 ACO/TO/ADS/3

4.16 3.44 2.63 - - - - - 2.2 4.9 ACO/TO/ADS/3

- 4.44 3.75 3.05 2.36 - - - 3.0 6.7 ACO/TO/ADS/3

- - - 4.30 3.61 3.05 - - 4.0 8.4 ACO/TO/ADS/3

- - - - 4.72 4.16 3.61 - 5.5 11.3 ACP/SD/ADS/3

- - - - - - - 4.44 7.5 14.8 ACP/SD/ADS/3

2 Speed Motors are available for KVB, KPB & KPB DUO models - see page 92 for details and refer to fan curves for selection

All models are suitable for both internal & external mounting

Rectangular & Square Duct Fans

Quick Selection Data

3

Page 26: Rectangular & Square Duct Fans

100

K-Fan

Rectangular & Square Duct Fans

KP DUO - Acoustic Twin Fan (Direct or Belt Driven)

The KP DUO is a range of acoustically treated in-line centrifugal twin fans for internal and external mounting with aluminum profile casing. The direct driven KPD DUO ranges from 700 to 7000 m3/h while the standard range belt driven KPB DUO reaches 19 500 m3/h. Static pressures up to 700 Pa.A rectangular inlet and outletallow an easy connection to ducts avoiding sudden pressure loss.9 sizes are available from 450 to 1000 mm height. Suitable for operations up to 50°C.

WarrantyKP DUO twin fans have a 2 year warranty

Features & BenefitsQuiet operation• Aluminumprofileheavydutycasing

with 15 mm isolation on galvanized steel panels

• Fanandmotorsupportedona

metallic frame with built in vibration isolationQuality impellers and motors• Highly efficient forward curved

double inlet galvanized steel impeller.• IP 55 F Class motors, belt driven

(three phase). Direct drive IP 54 F Class single phase except

12-12-D6.Easy installation & maintenance• IP 55 wired connection box for easy

wiring of the two motors.

• Maintenance access door with lock and key.

Special arrangements60 Hz three phase

Performances curvesBelt driven see pages 95-97Direct driven see pages 93-94Wiring diagrams pages 89 & 92

• KPB DUO – Double inlet belt driven range with airflows from 10,000 to 19,500 m3/h (2.77m3/s to 5.41m3/s) Run & Standby Fan

• KPD DUO – Double inlet direct driven range with airflows from 700 to 7,000 m3/h (0.2m3/s to 1.94m3/s) Run & Standby Fan

• Suitable for mounting Outside

RetailToilets SchoolsIndustry

3

Quick Selection Tabulated Tables on page 98 & 99

Page 27: Rectangular & Square Duct Fans

101

Rectangular & Square Duct Fans

K-FanKVB / KVD / KPB DUO Dimensions

KPB DUO Belt driven A B C D E

7/7 600 900 450 840 390

9/7 700 1100 550 1040 490

9/9 700 1100 550 1040 490

10/8 750 1300 600 1240 540

10/10 750 1300 600 1240 540

12/9 900 1600 700 1540 640

12/12 900 1600 700 1540 640

15/11 1000 1900 800 1840 740

15/15 1000 1900 800 1840 740

18/13 1150 2200 1000 2140 940

18/18 1150 2200 1000 2140 940

KPD DUO Direct driven A B C D E

7/7 450 900 450 840 390

9/7 500 1000 500 940 440

9/9 500 1000 500 940 440

10/8 550 1100 550 1040 490

10/10 550 1100 550 1040 490

12/9 630 1260 630 1200 570

12/12 630 1260 630 1200 570

AirflowSide view

Top view

3

Page 28: Rectangular & Square Duct Fans

102

K-Fan

Rectangular & Square Duct Fans

KVD / KVB / KPB / KPD DUO & KPB DUO - Specification Text

KVDDirect driven box fan for inline operation and suitable for outdoor installations fitted with a forward curve double inlet impeller and IP 54 F Class motors. The casing is made of 1 mm thick galvanized steel. The impel-ler shall be fitted on 4 anti-vibration rubber plots and its outlet connected with the casing through a 18 mm thick rubber joint. An IP 55 connection box is fitted on the casing for easy instal-lation.Maximum temperature of the transported air: 50°C

KVBBelt driven box fan for inline opertion and suitable for outdoor installations fitted with a forward curve double inlet impeller and IP 55 F Classmotors. The casing is made of 1 mm thick galvanized steel. The impeller and motor shall be fitted on agalvanized steel support with 4 anti-vibration rubber plots, the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. An IP 55 connection box is fitted on the casing for easy installation. Maximum temperature of the transported air: 50°C

KPBBelt driven box fan for inline or 90° operation suitable for outdoor instal-lation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminumprofile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyurethane foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steelsupport with 4 anti-vibration rubber plots and the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50°C

KPB DUOBelt driven twin fan for inlineoperation suitable for outdoorinstallation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminum profile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyure-thane foam insulation.A maintenance door with polyamide hinge and key is located on the side of the box. The impeller and motor shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and the impeller’s outlet connected with the casing through a 18 mm thick rubber joint. Maximum temperature of the transported air: 50°C. An IP 55 connection box for both motors is fitted on the casing.

KPD DUODirect driven twin fan for inline operation suitable for outdoor installation fitted with a forward curve double inlet impeller and IP 55 F Class motors. The casing is made of aluminumprofile structure and 1 mm galvanized steel panels fitted with 15 mm M1 polyurethane foam insulation. A maintenance door with polyamide hinge and key is located on the side of the box. The impeller shall be fitted on a galvanized steel support with 4 anti-vibration rubber plots and its outlet connected with the casingthrough a 18 mm thick rubber joint. Maximum temperature of thetransported air: 50°C. An IP 55 connection box for both motors is fitted on the casing.

3

KP DUO

KPB

KVD