REBLE310 ODU Microwave Link
23/07/2013
www.elber.com
Elber s.r.l. - Via Pontevecchio, 42W Phone +39-0185.35.13.33
16042 Carasco (GE) Italy Fax +39-0185.35.13.00
REBLE310-ODU
User Manual
REBLE310 ODU Microwave Link
Page 2 of 70 Version 1.1
Summary.
REBLE310-ODU....................................................................................................................................... 1
USER MANUAL ....................................................................................................................................... 1
SUMMARY. ............................................................................................................................................ 2
FIGURE INDEX. ....................................................................................................................................... 5
1 SAFETY REGULATIONS. ................................................................................................................... 10
1.1 TREATMENT OF ELECTRICAL SHOCKS. ........................................................................................ 10
1.2 TREATMENT OF ELECTRICAL BURNS. .......................................................................................... 11
2 GENERAL DESCRIPTION. .................................................................................................................. 12
3 TECHNICAL SPECIFICATIONS. ........................................................................................................... 12
3.1 RF MODULES DETAILS. ...................................................................................................................... 14
3.2 MODEM DETAILS. ............................................................................................................................ 14
3.3 I/O DETAIL. .................................................................................................................................... 14
3.4 GENERAL SPECIFICS. .......................................................................................................................... 15
3.5 MECHANICAL SPECIFICATIONS. ............................................................................................................ 15
4 INSTALLATION. ............................................................................................................................... 15
5 USER INTERFACE. ............................................................................................................................ 16
5.1 MAIN MENU. .................................................................................................................................. 17
5.2 SUMMARY MENU. ............................................................................................................................ 18
5.3 IDU - CONTROLLER MENU. ................................................................................................................. 19
5.3.1 TOUCH SCREEN CALIBRATION..................................................................................................................... 19
5.3.2 LEFT FAN MENU. ...................................................................................................................................... 19
5.3.3 RIGHT FAN MENU. .................................................................................................................................... 20
5.3.4 NETWORK PARAMETER MENU 1/4. ............................................................................................................. 21
5.3.5 NETWORK PARAMETER MENU 2/4. ............................................................................................................. 21
REBLE310 ODU Microwave Link
Page 3 of 70 Version 1.1
5.3.6 NETWORK PARAMETER MENU 3/4. ............................................................................................................. 22
5.3.7 NETWORK PARAMETER MENU 4/4. ............................................................................................................. 22
5.3.8 MISCELLANEOUS MENU 1/3. ..................................................................................................................... 23
5.3.9 MISCELLANEOUS MENU 2/3. ..................................................................................................................... 23
5.3.10 MISCELLANEOUS MENU 3/3. ................................................................................................................... 24
5.3.11 SYSTEM TIME MENU. ............................................................................................................................. 24
5.4 IDU - I/O MENU. ............................................................................................................................ 25
5.4.1 I/O ASI A MENU. .................................................................................................................................... 26
5.4.2 I/O ASI B MENU. ..................................................................................................................................... 26
5.4.3 I/O ASI C MENU. ..................................................................................................................................... 27
5.4.4 I/O ASI D MENU. .................................................................................................................................... 27
5.4.5 I/O E1 MENU. ......................................................................................................................................... 28
5.4.6 I/O STM-1 MENU. .................................................................................................................................. 28
5.4.7 I/O GBE MENU. ...................................................................................................................................... 29
5.4.8 I/O CHANNEL BANDWIDTH ALLOCATION ..................................................................................................... 30
5.5 ODU - MODEM MENU. ..................................................................................................................... 31
5.5.1 MODEM MEASUREMENTS MENU. ............................................................................................................... 31
5.5.2 MODEM ALARMS MENU. ........................................................................................................................... 32
5.5.3 MODEM GENERAL MENU........................................................................................................................... 33
5.5.4 MODEM CONFIGURATION MENU. ............................................................................................................... 33
5.5.5 MODEM DATABASE MENU. ........................................................................................................................ 34
5.6 ODU - TX MENU. ............................................................................................................................ 35
5.7 ODU - RX MENU. ............................................................................................................................ 36
5.8 IDU - POWER SUPPLY MENU. ............................................................................................................. 36
5.9 ODU - POWER SUPPLY MENU. ............................................................................................................ 37
5.10 CABLE INTERFACE - POWER MENU. ..................................................................................................... 38
5.11 CABLE INTERFACE - SIGNAL MENU. ..................................................................................................... 38
6 WEB INTERFACE. ............................................................................................................................ 39
6.1 IDU MICROCONTROLLER BOARD. ........................................................................................................ 44
6.1.1 IDU MICROCONTROLLER – MISCELLANEOUS. ............................................................................................... 45
6.1.2 IDU MICROCONTROLLER – FAN CONTROL. ................................................................................................... 46
6.1.3 IDU MICROCONTROLLER – EVENTS LOG. ..................................................................................................... 46
6.1.4 IDU MICROCONTROLLER – NETWORKING. ................................................................................................... 47
6.1.5 IDU MICROCONTROLLER – TEMPERATURE. .................................................................................................. 48
REBLE310 ODU Microwave Link
Page 4 of 70 Version 1.1
6.1.6 IDU MICROCONTROLLER – RELAYS. ............................................................................................................ 48
6.1.7 IDU MICROCONTROLLER – STATS. .............................................................................................................. 49
6.1.8 IDU MICROCONTROLLER – TRAPS. ............................................................................................................. 50
6.1.9 IDU MICROCONTROLLER – CONFIGURATION AND PASSWORD MANAGER ......................................................... 51
6.2 IDU I/O BOARD. ............................................................................................................................. 52
6.3 ODU MODEM BOARD. ..................................................................................................................... 54
6.3.1 ODU MODEM – ALARMS. ........................................................................................................................ 54
6.3.2 ODU MODEM – MEASUREMENTS. ............................................................................................................. 55
6.3.3 ODU MODEM – CONFIGURATIONS. ........................................................................................................... 56
6.3.4 ODU MODEM – MISCELLANEOUS. ............................................................................................................. 58
6.4 ODU TX BOARD. ............................................................................................................................. 59
6.4.1 ODU TX – CENTRAL FREQUENCY. ............................................................................................................... 59
6.4.2 ODU TX – POWER. .................................................................................................................................. 59
6.4.3 ODU TX – SQUELCH CTRL. ........................................................................................................................ 60
6.4.4 ODU TX – LOCK. ..................................................................................................................................... 61
6.4.5 ODU TX – TEMPERATURE. ........................................................................................................................ 61
6.4.6 ODU TX – PART AND SERIAL NUMBER. ....................................................................................................... 61
6.5 ODU RX BOARD. ............................................................................................................................. 61
6.5.1 ODU RX – CENTRAL FREQUENCY................................................................................................................ 62
6.5.2 ODU RX – RSSI. ..................................................................................................................................... 62
6.5.3 ODU RX – LOCK. ..................................................................................................................................... 62
6.5.4 ODU RX – TEMPERATURE. ........................................................................................................................ 63
6.5.5 ODU RX – PART AND SERIAL NUMBER. ....................................................................................................... 63
6.6 ODU MICROCONTROLLER. ................................................................................................................. 63
6.7 ODU POWER SUPPLY. ...................................................................................................................... 63
6.8 CABLE INTERFACE. ............................................................................................................................ 64
7 PANELS. ......................................................................................................................................... 65
7.1 FRONT PANEL. ................................................................................................................................ 65
7.2 BACK PANEL. .................................................................................................................................. 65
7.2.1 I/O PANELS. ........................................................................................................................................... 66
8 MAINTENANCE. .............................................................................................................................. 67
8.1 FAN REPLACING. .............................................................................................................................. 67
REBLE310 ODU Microwave Link
Page 5 of 70 Version 1.1
8.2 POWER SUPPLY REPLACING. ................................................................................................................ 69
Figure index. Figure 1: Resuscitation detail – 1. ................................................................................................................... 10
Figure 2: Resuscitation detail – 2. ................................................................................................................... 10
Figure 3: Resuscitation detail – 3. ................................................................................................................... 10
Figure 4: Resuscitation detail – 4. ................................................................................................................... 10
Figure 5: Resuscitation detail – 5. ................................................................................................................... 11
Figure 6: Read only access. .............................................................................................................................. 16
Figure 7: R/W access. ...................................................................................................................................... 16
Figure 8: Password menu ................................................................................................................................ 16
Figure 9: Main menu ....................................................................................................................................... 17
Figure 10: ODU Main menu ............................................................................................................................. 17
Figure 11: IDU Main menu............................................................................................................................... 18
Figure 12: FD Summary menu ......................................................................................................................... 18
Figure 13: Tx Summary menu .......................................................................................................................... 18
Figure 14: Rx Summary menu .......................................................................................................................... 18
Figure 15: Touch Screen Calibration Menu ..................................................................................................... 19
Figure 16: Touch Screen Calibration Menu with suggested cross ................................................................... 19
Figure 17: “Successfully finished calibration” message. ................................................................................. 19
Figure 18: “Calibration in course” message. ................................................................................................... 19
Figure 19: “Touch Screen not calibrated” message. ....................................................................................... 19
Figure 20: Left fan menu ................................................................................................................................. 20
Figure 21: Right fan menu ............................................................................................................................... 20
Figure 22: Network parameter menu 1/4 ....................................................................................................... 21
Figure 23: Network parameter menu 2/4 ....................................................................................................... 21
Figure 24: Network parameter menu 3/4 ....................................................................................................... 22
Figure 25: Network parameter menu 3/4 ....................................................................................................... 22
Figure 26: Miscellaneous menu 1/3 ................................................................................................................ 23
Figure 27: Miscellaneous menu 2/3 ................................................................................................................ 23
Figure 28: Miscellaneous menu 3/3 ................................................................................................................ 24
Figure 29: Virtual Keyboard ............................................................................................................................. 24
Figure 30: Time setting menu. ......................................................................................................................... 25
Figure 31: STM1–2 ASI– E1 .............................................................................................................................. 25
Figure 32: 4 ASI– E1 ......................................................................................................................................... 25
Figure 33: ETH-2 ASI– E1. ................................................................................................................................ 25
REBLE310 ODU Microwave Link
Page 6 of 70 Version 1.1
Figure 34: ASI 'A' FD menu .............................................................................................................................. 26
Figure 35: ASI 'A' Tx menu ............................................................................................................................... 26
Figure 36: ASI 'A' Rx menu ............................................................................................................................... 26
Figure 37: ASI 'B' FD menu ............................................................................................................................... 26
Figure 38: ASI 'B' Tx menu ............................................................................................................................... 26
Figure 39: ASI 'B' Rx menu ............................................................................................................................... 26
Figure 40: ASI 'C' FD menu ............................................................................................................................... 27
Figure 41: ASI 'C' Tx menu ............................................................................................................................... 27
Figure 42: ASI 'C' Rx menu ............................................................................................................................... 27
Figure 43: ASI 'D' FD menu .............................................................................................................................. 27
Figure 44: ASI 'D' Tx menu ............................................................................................................................... 27
Figure 45: ASI 'D' Rx menu ............................................................................................................................... 27
Figure 46: E1 FD menu ..................................................................................................................................... 28
Figure 47: E1 Tx menu ..................................................................................................................................... 28
Figure 48: E1 Rx menu ..................................................................................................................................... 28
Figure 49: STM-1 FD menu .............................................................................................................................. 28
Figure 50: STM-1 Tx menu ............................................................................................................................... 28
Figure 51: STM-1 Rx menu............................................................................................................................... 28
Figure 52: ETH FD menu .................................................................................................................................. 29
Figure 53: ETH Tx menu ................................................................................................................................... 29
Figure 54: ETH Rx menu ................................................................................................................................... 29
Figure 55: Ethernet Infoes ............................................................................................................................... 29
Figure 56: Ethernet Cable Status ..................................................................................................................... 30
Figure 57: Ethernet Link Status ....................................................................................................................... 30
Figure 58: Ethernet Flow Control .................................................................................................................... 30
Figure 59: ‘Channel Bandwith Allocation’ feature unavailable ....................................................................... 30
Figure 60: Channel Bandwith Allocation feature unavailable in case of Ethernet .......................................... 31
Figure 61: Channel Bandwith Allocation. Case respectively of: Stm1-2Asi-E1, 4Asi-E1, Eth,2Asi-E1.............. 31
Figure 62: Modem FD measurements menu. .................................................................................................. 32
Figure 63: Modem Tx measurements menu. .................................................................................................. 32
Figure 64: Modem Rx measurements menu. .................................................................................................. 32
Figure 65: Modem FD alarm menu .................................................................................................................. 32
Figure 66: Modem Tx alarm menu .................................................................................................................. 32
Figure 67: Modem Rx alarm menu .................................................................................................................. 32
Figure 68: Modem FD general menu ............................................................................................................... 33
REBLE310 ODU Microwave Link
Page 7 of 70 Version 1.1
Figure 69: Modem Tx general menu ............................................................................................................... 33
Figure 70: Modem Rx general menu ............................................................................................................... 33
Figure 71: Modem FD configuration menu ..................................................................................................... 34
Figure 72: Modem Tx configuration menu ...................................................................................................... 34
Figure 73: Modem Rx configuration menu ...................................................................................................... 34
Figure 74: Modulator database menu ............................................................................................................. 34
Figure 75: Demodulator database menu ........................................................................................................ 34
Figure 76: Transmitter menu ........................................................................................................................... 35
Figure 77: Receiver menu. ............................................................................................................................... 36
Figure 78: Power Supply menu. ....................................................................................................................... 37
Figure 79: DC supply icon, primary position .................................................................................................... 37
Figure 80: DC supply icon, secondary position ................................................................................................ 37
Figure 81: AC supply icon, primary position .................................................................................................... 37
Figure 82: AC supply icon, secondary position ................................................................................................ 37
Figure 83: ODU Power Supply menu. .............................................................................................................. 37
Figure 84: Cable Interface Power menu. ......................................................................................................... 38
Figure 85: Cable Interface ODU Power-down Confirmation form. ................................................................. 38
Figure 86: Cable Interface Signal menu. .......................................................................................................... 39
Figure 87: First page Web interface. ............................................................................................................... 39
Figure 88: Main Web interface page.If you click on ‘IDU’ you’ll have : ........................................................... 40
Figure 89: WEB IDU Main page ....................................................................................................................... 40
Figure 90: Web Cable interface. ...................................................................................................................... 41
Figure 91: WEB ODU Main page - FD .............................................................................................................. 41
Figure 92: WEB ODU Main page – Tx .............................................................................................................. 42
Figure 93: WEB OSU Main page – Rx ............................................................................................................... 42
Figure 94: Web IDU Main page, with alarm indication. .................................................................................. 43
Figure 95: IDU Microcontroller WEB Page ...................................................................................................... 44
Figure 96: Microcontroller Web page - Miscellaneous. .................................................................................. 45
Figure 97: Microcontroller WEB page – Left fan control. ................................................................................ 46
Figure 98: Microcontroller WEB page – Right fan control .............................................................................. 46
Figure 99: Microcontroller Web page – networking. ...................................................................................... 47
Figure 100: Network Configuration Web page ................................................................................................ 48
Figure 101: Microcontroller web page – temperature.................................................................................... 48
Figure 102: Microcontroller WEB page – Relays management. ...................................................................... 48
Figure 103: Alarm conditions list page ............................................................................................................ 49
REBLE310 ODU Microwave Link
Page 8 of 70 Version 1.1
Figure 104: Microcontroller WEB page – Statistics. ........................................................................................ 49
Figure 105: Microcontroller WEB page - Traps. .............................................................................................. 50
Figure 106: Microcontroller WEB page – Traps Management. ....................................................................... 50
Figure 107: I/O board WEB page, 4 ASI FD case. ............................................................................................. 52
Figure 108: I/O channels enabling/disabling and output frame, GbE and 4 ASI case. .................................... 53
Figure 109: Channel bitrate settings. .............................................................................................................. 53
Figure 110: ASI A input frame. ......................................................................................................................... 53
Figure 111: Modem FD WEB page. .................................................................................................................. 54
Figure 112: Modem WEB page - Alarms. ......................................................................................................... 54
Figure 113: Modem WEB page - Measurements. ........................................................................................... 55
Figure 114: Modem WEB page - Configurations. ............................................................................................ 56
Figure 115: Modem WEB page - BER threshold update .................................................................................. 56
Figure 116: Modulator configurations database WEB page. .......................................................................... 57
Figure 117: Modulator configurations database WEB page while changing configuration. ........................... 57
Figure 118: Mod and dem selection tab detail. .............................................................................................. 58
Figure 119: Modem WEB page - Miscellaneous. ............................................................................................. 58
Figure 120: Tx board WEB page. ..................................................................................................................... 59
Figure 121: Tx WEB page- Central Frequency. ................................................................................................ 59
Figure 122: Tx WEB page - Power. ................................................................................................................... 59
Figure 123: Tx WEB page - Power with manual ALC. ...................................................................................... 60
Figure 124: Tx WEB page - Squelch Control. ................................................................................................... 60
Figure 125: Tx WEB page - Lock. ...................................................................................................................... 61
Figure 126: Tx WEB page - Temperature. ........................................................................................................ 61
Figure 127: Tx WEB page - Part and Serial Number. ....................................................................................... 61
Figure 128: Rx board WEB page. ..................................................................................................................... 61
Figure 129: Rx WEB page - Central Frequency. ............................................................................................... 62
Figure 130: Rx WEB page - RSSI. ...................................................................................................................... 62
Figure 131: Rx WEB page - Lock. ..................................................................................................................... 62
Figure 132: Rx WEB page - Temperature. ....................................................................................................... 63
Figure 133: Rx WEB page - Part and Serial Number. ....................................................................................... 63
Figure 134: ODU uc Infoes. .............................................................................................................................. 63
Figure 135: ODU Power Supply. ...................................................................................................................... 64
Figure 136: ODU Cable Infoes.......................................................................................................................... 64
Figure 137: ODU Power Down confirmation. .................................................................................................. 65
Figure 138: Front panel ................................................................................................................................... 65
REBLE310 ODU Microwave Link
Page 9 of 70 Version 1.1
Figure 139: IDU back panel – cable interface. ................................................................................................. 66
Figure 140: STM-1 interface version back panel. ............................................................................................ 66
Figure 141: 4 ASI interface version back panel. .............................................................................................. 66
Figure 142: Left fan .......................................................................................................................................... 67
Figure 143: Left fan screws removal - 1. ......................................................................................................... 69
Figure 144: Left fan screws removal - 2. ......................................................................................................... 69
Figure 145: Left fan screws removal - 3. ......................................................................................................... 69
Figure 146: Left fan screws removal - 4. ......................................................................................................... 69
Figure 147: AC supply cable removal. ............................................................................................................. 69
Figure 148: Fixing screws removal. ................................................................................................................. 69
Figure 149: Module extraction. ....................................................................................................................... 70
Figure 150: Module insertion. ......................................................................................................................... 70
REBLE310 ODU Microwave Link
Page 10 of 70 Version 1.1
1 Safety regulations.
The personnel engaged with the installation, the use and the maintenance of the equipment has to be
familiar with the theory and practice of first aid.
1.1 Treatment of electrical shocks.
When the victim loses his consciousness:
Put into practice the following first aid principles.
Position the victim lying down on his back on a rigid surface.
Open the respiratory airways lifting up the neck and pushing down the front (Fig. 1).
If necessary, open the mouth to check the respiration.
In case the victim doesn’t breath, start immediately the artificial respiration (figure 2): bend the
head, close the nostrils, attach the mouth to the victim one’s and do 4 quick mouth-to-mouth
respirations
Figure 1: Resuscitation detail – 1.
Figure 2: Resuscitation detail – 2.
Check the pulsation (Figure 3); in case of absence of pulsation, start immediately the cardiac
massage (Figure 4) pressing the breastbone in the middle of the thorax (Figure 5).
Figure 3: Resuscitation detail – 3.
Figure 4: Resuscitation detail – 4.
REBLE310 ODU Microwave Link
Page 11 of 70 Version 1.1
Figure 5: Resuscitation detail – 5.
When there is only one rescuer, he has to maintain a rhythm of 15 compressions alternated with 2
quick respirations.
In case there are two rescuers, the rhythm should be one respiration each 5 compressions.
Do not interrupt the cardiac massage during the artificial breathing
Call a doctor as soon as possible
When the victim is conscious
Cover up the victim with a blanket.
Try to calm down the victim.
Unbutton the cloche and lay down the victim.
Call a doctor as soon as possible.
1.2 Treatment of electrical burns.
Large burns and cuts of the skin
Cover up the interested area with a clean sheet or cloth.
Do not open the blisters; remove the fabric and the parts of the clothes attached to the skin; apply
a suitable ointment.
Treat the victim according to the type of accident.
Take the victim to the hospital as soon as possible.
When the arms and legs are affected keep them raised.
When there is no doctor available within an hour and the victim is conscious and does not retch, give a
liquid solution containing salt and sodium bicarbonate: 1 teaspoon of salt and half a teaspoon of sodium
bicarbonate for each 250 ml of water.
Have the victim sip half a glass of the solution for four times and for 15 minutes.
Stop when retching.
Do not give any alcoholics
Less serious burns
Apply cold (not frozen) gauzes using a clean as possible cloth.
Do not open the blisters; remove the fabric and the parts of the clothes attached to the skin; apply
a suitable ointment.
When necessary, put on clean and dry clothes.
REBLE310 ODU Microwave Link
Page 12 of 70 Version 1.1
Treat the victim according to the type of accident.
Take the victim to the hospital as soon as possible.
When the arms and legs are affected keep them raised.
2 General Description.
The REBLE310-ODU is the outdoor version of the REBLE310, from which it differs for the separation
between modem and RF part (both located in a waterproof aluminum case) from the digital I/O section and
control.
The indoor unit or control unit (REBLE310-IDU) belongs to the same chassis of the REBLE310, and it is
realized in a new, compact (1U rack 19”) and high-end solution. A double hot-swappable power supply is
also present, available both in AC and DC version.
The improved ICs technology allows the implementation of direct frequency conversion from baseband I/Q
components to the final frequency, without IF stages. This assures no spurious emissions due to L.O. and
very compact sizes of both transmitter and receiver modules.
Mono and bidirectional configurations are available, as well as a relay version with the possibility of
asymmetrical configurations regarding frequency range and modulation schemes.
The high clock frequency allows the link achieve up to 40MHz bandwidth, transporting a 200 Mbit/s
payload in 128 QAM modulation. The I/O section is to be chosen depending on the application; 3 versions
are available: the first one with 4 ASI/BTS channels and one E1, the second with 2 ASI/BTS channels, one
STM-1 and one E1 and the third with 2 ASI/BTS, 1 E1 and a GbE port.
Many accessories are integrated in order to optimize spaces in remote sites, such as the hitless switch for
redundant configurations, the double hot-swappable power supply. A new embedded software offers
complete control of all parameters of the link, driving an easy user interface with a TFT touch screen and a
keyboard accessible from the front panel, for very simple and immediate maintenance and
troubleshooting. An intuitive web interface allows a local or remote user to manage the equipment, as well
as through SNMP protocol.
3 Technical Specifications. Table 1
Configuration Bidirectional or Mono-directional
Conversion Direct
Operating frequency
ODUxx can be
ODUFD -> Full Duplex
ODUTX -> Transmitter
ODURX -> Receiver
REBLE310/ODUxx/05: 5.0 - 5.5 GHz
REBLE310/ODUxx/06: 5.8 - 7.2 GHz
REBLE310/ODUxx/07: 7.2 – 7.8 GHz
REBLE310/ODUxx/10: 9.5 - 10.8 GHz
REBLE310/ODUxx/11: 10.7 - 11.8 GHz
REBLE310/ODUxx/13: 12.7 - 13.2 GHz
REBLE310/ODUxx/14: 14.0 – 15.3 GHz
Coverage Up to 1 GHz
Frequency resolution 250 KHz
Output power @ 1 db Compression
point
ODUxx can be
ODUFD -> Full Duplex
ODUTX -> Transmitter
REBLE310/ODUxx/05: 30 dBm
REBLE310/ODUxx/06: 30 dBm
REBLE310/ODUxx/07: 30 dBm
REBLE310/ODUxx/10: 29 dBm
REBLE310/ODUxx/11: 29 dBm
REBLE310 ODU Microwave Link
Page 13 of 70 Version 1.1
REBLE310/ODUxx/13: 28 dBm
REBLE310/ODUxx/14: 28 dBm
RF connector
ODUxx can be
ODUFD -> Full Duplex
ODUTX -> Transmitter
ODURX -> Receiver
REBLE310/ODUxx/05: female N
REBLE310/ODUxx/06: female N or IEC UBR 70
REBLE310/ODUxx/07: female N or IEC UBR 70 or
IEC UBR 84
REBLE310/ODUxx/10: IEC UBR 120
REBLE310/ODUxx/11: IEC UBR 120
REBLE310/ODUxx/10: IEC UBR 140
RF Output Return Loss > 23 dB
RF Input Return Loss > 26 dB
Spurious suppression > 60 dBc
Frequency stability < ± 2.5 ppm
Standard filter canalization 28 MHz
Modulation schemes QPSK, 16QAM, 32QAM, 64QAM, 128QAM, 256QAM
Capacity* Up to 210 Mbit/s
Table 2: Examples of performances in 28 MHz canalization.
Modulation Back off Sensitivity Payload
QPSK -2 dB -90 dBm 27 Mbit/s
16QAM -3 dB -82 dBm 52 Mbit/s
32QAM -5 dB -79 dBm 92 Mbit/s
64QAM -5 dB -76 dBm 112 Mbit/s
128QAM -6 dB -71 dBm 160 Mbit/s
256QAM -7 dB -68 dBm 180 Mbit/s
REBLE310 ODU Microwave Link
Page 14 of 70 Version 1.1
3.1 RF modules details. Table 3
Module Range[GHz]
Transmitter 5 GHz 4.75-5.4
Receiver 5 GHz 4.75-5.4
Transmitter 6 GHz 5.55-6.2
6.2-6.7
6.25-6.95
6.8-7.2
Booster 6 GHz 5.3-5.9
5.9-6.4
6.4-7.2
Receiver 6 GHz 5-5.4
5.3-5.9
5.55-6.2
5.75-6.4
6.2-6.7
6.25-6.95
6.8-7.2
Transmitter 7 GHz 7.8-8.1
Booster 7 GHz 7.8-8.1
Receiver 7 GHz 7.8-8.1
Transmitter 10 Ghz 9.5-10.8
Booster 10 GHz 9.5-10.5 (up to 10.7)
Receiver 10 GHz 9.5-10.8
10.6-11.8
11.5-12.8
12.5-13.9
Transmitter 11 Ghz 10.6-11.8
Booster 11 GHz 10.7-11.7
Transmitter 14 Ghz 13.6-14.9
Receiver 14 GHz 13.6-14.9
3.2 Modem details. All modem parameters are bound to the Elber laboratory setup and they cannot be modified manually.
Table 4
Modulation scheme QPSK, 16-32-64-128-256 QAM
Protection codes * Internal: Convolutional, PTCM
Code rate 1/2 ÷ 13/14.
External: Reed-Solomon (M,N) M < 256, N<17
Maximum Symbol rate 31 MBaud
Band* 1.75 ÷ 40 MHz
Filter Roll-off factor * 0.15 ÷ 0.30
3.3 I/O detail. Table 5
Available boards 4 x DVB-ASI + E1
2 x DVB-ASI + E1 + STM-1
2 x DVB-ASI + E1 + GbE
Input connectors ASI/E1: BNC 75 Ohm
GbE: RJ-45
REBLE310 ODU Microwave Link
Page 15 of 70 Version 1.1
Output connectors ASI/E1: BNC 75 Ohm
GbE: RJ-45
Auxiliary ASI output connectors SMB 75 Ohm unbalanced
3.4 General specifics. Table 6
Temperature Range -5°C ÷ 50°C
Management Keyboard + TFT
Web GUI
SNMP
Firmware upgrade RS-232, JTAG, FTP (for FPGA)
Power supply Two hot-swappable boards.
1. AC 90-260 VAC
2. DC 22 a 65 V, galvanically isolated
Maximum power
consumption
120 W
3.5 Mechanical specifications. Table 7: IDU
Rack Standard 19” 1U
Width 482 mm
Height 44 mm
Depth 480 mm
Maximum weight 6.5 Kg
Table 8: ODU
Width 109 mm
Height 230 mm
Depth 409 mm (including RF connectors)
Maximum weight 10 Kg
4 Installation.
Unpack the equipment and check first of all check if there are any damages due to the transport.
The box should contain:
o The RF Head REBLE310-ODU (ODU).
o Hanger kit (if bought)
o The control unit REBLE310-IDU (IDU).
o The interconnection cable between IDU and ODU.
o One or two AC power supply cables, depending on power source options bought.
o One or two DC power supply cables, depending on power source options bought.
o The user manual
Install the control unit in a rack cabinet standard EIA310. A one-unit space is requested.
REBLE310 ODU Microwave Link
Page 16 of 70 Version 1.1
Make sure that there is enough space between other functioning equipment generating high
temperatures and that there are no obstructions in the ventilation. (The functioning is guaranteed in
a temperature range from -10 ºC ÷ +55 ºC).
The equipment must be correctly grounded, to guarantee a secure functioning.
Be sure of the correct power voltage reading the information on the manual or on the label attached
to each equipment, containing the serial number.
Install the RF Head using the hanger kit for on mast or tower mounting.
Connect the flange(s) of the equipment to the antenna system for the connection to the branching
system and the antenna.
Connect the cable between IDU and ODU.
Connect the supply cable(s) to the plug(s) on the back panel of the IDU
Configure the equipment according to the needs consulting the user manual.
5 User Interface. The user interface consists of a 6-key keyboard, a general alarm led and a graphical TFT display.
The directional keys allow the repositioning of the cursor between the active areas of a page; the active
areas are listed and explained further on in this paragraph. The ENTER key is used to confirm the selection
while the ESC key is used to return to the former menu.
Nevertheless the much easier, but more delicate, TOUCH SCREEN function is enabled. It is highly
recommended not to use the fingers but a piece of plastic, or in case, even a toothpick, to access all angels
of the display.
According to the configuration of the device -Monodirectional Transmitter (Tx), Monodirectional Receiver
(Rx) and Bidirectional (FD) - the pertinent menus are highlighted hereafter.
In order to modify the equipment parameters, a login procedure is needed clicking on active area shown in
next figure.
Figure 6: Read only access.
Figure 7: R/W access.
Figure 8: Password menu
Password to be inserted is “evviva”. Confirm clicking on the active area .
REBLE310 ODU Microwave Link
Page 17 of 70 Version 1.1
5.1 Main menu. Starting up the device, after the loading of the embedded software, on the displays appears the main menu
according to the chosen configuration as shown in Figure 9, Figure 10 and Figure 11.
The menu represents summarily the block diagram of the equipment, facilitating and intuitive access to the
parameters of each module; the cursor moves clock wisely pressing the right key and anti-clock wisely
pressing the left key. The ENTER key confirms the access to the selected active area (highlighted by an
empty rectangle with red outlines ) while the ESC key accesses the main menu.
Each active area has one or more circles stylizing the alarm led; turning red or green in case the active area
presents or not an alarm condition.
Figure 9: Main menu
Active areas selecting ODU:
Rx
Tx
Modem
uC
PS
Figure 10: ODU Main menu
REBLE310 ODU Microwave Link
Page 18 of 70 Version 1.1
Active areas selecting IDU:
IO
uC
PS
Figure 11: IDU Main menu
5.2 Summary menu. The summary menu, viewable pressing the ‘Esc’ key ( or touching the ‘UP’ key ) from the main menu, shows
the most important information for a quick monitoring of the functioning of the equipment. We indeed find
here:
Power out (FD and Tx)
RSSI Received Signal Strength Indication (FD and Rx)
Timing Loop (FD and Tx)
Dem Lock (FD and Rx)
Figure 12: FD Summary menu
Figure 13: Tx Summary menu
Figure 14: Rx Summary menu
Active areas
Directional key “UP” to return to the main menu
REBLE310 ODU Microwave Link
Page 19 of 70 Version 1.1
5.3 IDU - Controller menu. The system’s controller menu is composed of 11 pages that can vary along the configuration as shown
hereunder.
5.3.1 Touch Screen Calibration.
The menu allows the calibration of the touch screen.
Figure 15: Touch Screen Calibration Menu
Use a stick and hit the suggested cross for three times once chosen the key “Calibrate”.
Figure 16: Touch Screen Calibration Menu with suggested cross
Active areas:
Directional keys “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
“Calibrate Button” to enable the calibration.
The text box on the lower right part shows the following auto explicative messages:
Figure 17: “Successfully finished calibration” message.
Figure 18: “Calibration in course” message.
Figure 19: “Touch Screen not calibrated” message.
5.3.2 Left fan menu.
The menu allows managing the functioning of the left fan.
REBLE310 ODU Microwave Link
Page 20 of 70 Version 1.1
In the default mode the left fan is automatically piloted based on the lecturing of the microcontroller
temperature sensor and based on the targets configured on the same menu.
Passing on to the manual mode, the speed rate needs to be set up on corresponding Checkbox.
Figure 20: Left fan menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox Manual for the manual speed setup
Arrows to increase/decrease the values of the left fan speed range, receiver target
temperature, microcontroller target temperature.
5.3.3 Right fan menu.
The menu allows managing the functioning of the right fan.
In the default mode the right fan is automatically piloted based on the lecturing of the communication
board and ODU power supply board and based on the targets configured on the same menu.
Passing on to the manual mode, the speed rate needs to be set up on corresponding Checkbox.
Figure 21: Right fan menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox Manual for the manual speed setup
Arrows to increase/decrease the values of the right fan speed range, transmitter target
temperature, booster target temperature.
REBLE310 ODU Microwave Link
Page 21 of 70 Version 1.1
5.3.4 Network parameter menu 1/4.
Through this menu the network parameters for the communication with the management gates can be
modified.
More specifically the IP address and the Subnet Mask can be configured.
Figure 22: Network parameter menu 1/4
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Arrows to increase/decrease the values regarding the IP address and the Subnet Mask.
5.3.5 Network parameter menu 2/4.
Through this menu the network parameters for the communication with the management gates can be
modified.
More specifically the Gateway network address can be configured and it is possible to verify the MAC level.
Figure 23: Network parameter menu 2/4
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Arrows to increase/decrease the values regarding the IP address of the Gateway network.
REBLE310 ODU Microwave Link
Page 22 of 70 Version 1.1
5.3.6 Network parameter menu 3/4.
Through this menu the network parameters for the communication with the management gates can be
modified.
More specifically it is possible to configure the addresses of the 2 SNMP managers to which the traps are
sent.
Figure 24: Network parameter menu 3/4
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Arrows to increase/decrease the values regarding the IP address of the SNMP manager.
5.3.7 Network parameter menu 4/4.
Through this menu the network parameters for the communication with the management gates can be
modified.
More specifically it is possible to configure the addresses of the 2 SNMP managers to which the traps are
sent.
Figure 25: Network parameter menu 3/4
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Arrows to increase/decrease the values regarding the IP address of the SNMP manager.
REBLE310 ODU Microwave Link
Page 23 of 70 Version 1.1
5.3.8 Miscellaneous menu 1/3.
The menu reports general information, such as:
Embedded software version
FPGA firmware version
Customer name
Figure 26: Miscellaneous menu 1/3
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
5.3.9 Miscellaneous menu 2/3.
The menu reports general information, such as:
Part Number
Model
Serial Number
Figure 27: Miscellaneous menu 2/3
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
REBLE310 ODU Microwave Link
Page 24 of 70 Version 1.1
5.3.10 Miscellaneous menu 3/3.
The menu reports general information, such as:
Inventory characteristics (to be registered by the customer)
General description of the device.
Figure 28: Miscellaneous menu 3/3
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Box Inventory.
Clicking on Inventory box, a virtual keyboard, shown in Figure 29, appears, in order to modify the inventory
label.
Figure 29: Virtual Keyboard
5.3.11 System Time Menu.
The menu let the user set timing information, utilized by the system for the alarm log.
This information is maintained by the Real Time Clock through the back-up battery.
REBLE310 ODU Microwave Link
Page 25 of 70 Version 1.1
Figure 30: Time setting menu.
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Arrows to increase/decrease the values regarding date and time.
5.4 IDU - I/O menu. From the IDU main menu, pressing the ‘I/O’ menu, depending on the installed interface, one of the
following sub menu is shown:
Figure 31: STM1–2 ASI– E1
Figure 32: 4 ASI– E1
Figure 33: ETH-2 ASI– E1.
Active areas:
Directional key “UP” to return to the previous menu
to go to the ASI ‘A’ menu
to go to the ASI ‘B’ menu
or or to go, respectively, to the ASI ‘C’ menu or
To the STM1 menu or to the ETHERNET one
Eventually to go to the ASI ‘D’ menu
to go to the ‘Channel Bandwith Allocation’ menu
REBLE310 ODU Microwave Link
Page 26 of 70 Version 1.1
5.4.1 I/O ASI A menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of ASI A
input and output buffers, connected to ASI 1 IN, ASI 1 OUT and AUX connectors of the back panel.
Moreover, it’s possible to monitor the channel A bitrate and to enable/disable the channel itself.
The menu is present in the 4 ASI and in the STM-1 version.
Figure 34: ASI 'A' FD menu
Figure 35: ASI 'A' Tx menu
Figure 36: ASI 'A' Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port
5.4.2 I/O ASI B menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of ASI B
input and output buffers, connected to ASI 2 IN, ASI 2 OUT and AUX connectors of the back panel.
Moreover, it’s possible to monitor the channel B bitrate and to enable/disable the channel itself.
The menu is present in the 4 ASI and in the STM-1 version.
Figure 37: ASI 'B' FD menu
Figure 38: ASI 'B' Tx menu
Figure 39: ASI 'B' Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port.
REBLE310 ODU Microwave Link
Page 27 of 70 Version 1.1
5.4.3 I/O ASI C menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of ASI C
input and output buffers, connected to ASI 3 IN, ASI 3 OUT and AUX connectors of the back panel.
Moreover, it’s possible to monitor the channel C bitrate and to enable/disable the channel itself.
The menu is present in the 4 ASI version.
Figure 40: ASI 'C' FD menu
Figure 41: ASI 'C' Tx menu
Figure 42: ASI 'C' Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port.
5.4.4 I/O ASI D menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of ASI D
input and output buffers, connected to ASI 4 IN, ASI 4 OUT and AUX connectors of the back panel.
Moreover, it’s possible to monitor the channel D bitrate and to enable/disable the channel itself.
The menu is present in the 4 ASI version.
Figure 43: ASI 'D' FD menu
Figure 44: ASI 'D' Tx menu
Figure 45: ASI 'D' Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port.
REBLE310 ODU Microwave Link
Page 28 of 70 Version 1.1
5.4.5 I/O E1 menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of E1
input and output buffers, connected to E1 IN and E1 OUT connectors of the back panel.
Moreover, it’s possible to enable/disable the channel itself.
The menu is present in the 4 ASI and in the STM-1 version.
Figure 46: E1 FD menu
Figure 47: E1 Tx menu
Figure 48: E1 Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port.
5.4.6 I/O STM-1 menu.
The menu let the user verify the presence, the locking status and eventual overrun and underrun of STM-1
input and output buffers, connected to STM-1 IN, STM-1 OUT and AUX connectors of the back panel.
Moreover, it’s possible to enable/disable the channel itself.
The menu is just in the STM-1 version.
Figure 49: STM-1 FD menu
Figure 50: STM-1 Tx menu
Figure 51: STM-1 Rx menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the micro controller menu.
Checkbox for enabling and disabling of the input or the output port.
REBLE310 ODU Microwave Link
Page 29 of 70 Version 1.1
5.4.7 I/O GbE Menu.
The menu let the user verify the pause, the locking status and eventual overrun and underrun of Ethernet
input and output buffers, connected to RJ-45 connector of the back panel.
Moreover, it’s possible to enable/disable the channel itself.
The menu is just in the ETH version.
Figure 52: ETH FD menu
Figure 53: ETH Tx menu
Figure 54: ETH Rx menu
Active areas:
Directional key “UP” to return to the previous menu
Info button “ to go to the following form
5.4.7.1 I/O Eth Info menu.
By activating the button present in the previous menu, the following form is shown.
It summarizes a number of information about the “Cable Status”, the ‘Link Status’, and the ‘Flow Control’.
Figure 55: Ethernet Infoes
5.4.7.1.1 Cable Status
This shows the status of the ethernet cable connected to the interface. For each couple it informs if there is
a faulted connection : normally they should be ‘Straight’.
The MDIX field informs if the TX and RX of the cable were crossed or not.
REBLE310 ODU Microwave Link
Page 30 of 70 Version 1.1
Figure 56: Ethernet Cable Status
5.4.7.1.2 Link Status
This shows the status of the ethernet link, in terms of speed, connection, negotiation of duplex, or half
duplex for example, and informs about the role (Master or Slave) of the interface.
Figure 57: Ethernet Link Status
5.4.7.1.3 Flow Control
This allows the user to send the ‘Pause’ frames, through the ‘OUT’ checkbox, to accept them, through the
‘IN’ checkbox, and to accept the ‘UNICAST ‘ones.
Figure 58: Ethernet Flow Control
Active areas:
The previous three checkboxes
Directional key “UP” to return to the previous menu
5.4.8 I/O Channel Bandwidth Allocation
This feature has to be enable by the factory.
In case it was not available, once activated, the following form will be shown:
Figure 59: ‘Channel Bandwith Allocation’ feature unavailable
An exception must be reported if the managed interface was the ‘Ethernet’ one: in this case a portion of
band must be reserved to the Ethernet data stream :
REBLE310 ODU Microwave Link
Page 31 of 70 Version 1.1
Figure 60: Channel Bandwith Allocation feature unavailable in case of Ethernet
In case of available feature, depending on the installed interface we’ll see:
Figure 61: Channel Bandwith Allocation. Case respectively of: Stm1-2Asi-E1, 4Asi-E1, Eth,2Asi-E1
This feature allows to assign a limit to the band any flow can use. This allows, in case for example one ASI
flow exceeds ,for any reason, from the foreseen band, to avoid to damage the other flows. You can note
that the E1 flows and the STM1 one are not addressable, because they are synchronous.
All the other may be fixed by the user using the nowadays usual arrows.
The ‘NET B.RATE’ field shows the whole available band.
Active areas:
Directional key “UP” to return to the previous menu
Arrows to increase/decrease the value of the band to allocate to the related flow.
Arrows for band limit setting.
5.5 ODU - Modem menu. The modem menu is composed of some pages that let the monitoring and the configuration of main
parameters of the modulator and the demodulator. The two sections are completely independent and can
be configured asymmetrically.
Navigation through the pages is performed through directional arrows.
The configuration of the modem is performed loading configuration files stored in the SD card (up to 20
files); through the user interface it’s possible to browse the database in order to select the desired setting.
5.5.1 Modem measurements menu.
The measurements menu shows the modulator and the demodulator main parameters.
REBLE310 ODU Microwave Link
Page 32 of 70 Version 1.1
Figure 62: Modem FD
measurements menu.
Figure 63: Modem Tx measurements
menu.
Figure 64: Modem Rx
measurements menu.
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the modem menu.
For the modulator section, only the Symbol Rate measurement is available; this measure should fit the one
shown in the configurations database. See following paragraph for details.
The demodulator section presents 5 measures:
1. Carrier Offset shows the frequency difference between the received signal and 0 Hz. As the system
is a direct frequency conversion radio, this parameter is very important in order to avoid heavy
impairments of I and Q baseband components. An AFC (automatic frequency control) circuit s
always active in order to compensate for eventual RF oscillators drifts, caused by aging,
temperature or other eventual factors.
2. BER shows the Bit Error Rate before the Reed-Solomon decoder.
3. AGC shows the level of the demodulator automatic gain control circuit. This measures is not
important for the monitoring of the equipment.
4. The MSE (Mean Square Error) is the measure of the microwave link C/N. Depending on the
modulation scheme, there are different critical MSE levels. Please contact the supplier for further
information or refer to the test report to verify the MSE threshold for the actual configuration.
5. The Data Rate shows the actual configuration payload.
5.5.2 Modem alarms menu.
The alarms menu shows the most important alarms for the modulator and the demodulator.
Figure 65: Modem FD alarm menu
Figure 66: Modem Tx alarm menu
Figure 67: Modem Rx alarm menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the modem menu.
REBLE310 ODU Microwave Link
Page 33 of 70 Version 1.1
Timing Loop is the only alarm of the modulator section; if the modulator is not locked to the data clock, this
led is red and the link is compromised.
The demodulator section presents 3 alarms:
1. Lock alarm indicates the lock status of the demodulator.
2. BER Th. alarm indicates that the BER Before Reed-Solomon is above the threshold that has been set
by the user. As default this threshold is set to 2x10-4.
3. MSE Th. alarm indicates that the MSE value is below the threshold for the used modulation.
Attention:
The alarm icon relative to the FPGA Error indicates that the signal controller has not been programmed
correctly and the equipment cannot work. This kind of failure is to be signaled very quickly to the supplier.
5.5.3 Modem general menu.
The modem general menu shows the selected configurations for either modulator or demodulator. For
clarity and simplicity, just the modulation scheme, the occupied bandwidth and the net bitrate are shown.
Moreover it’s possible to set the internal generator of CW (Continuous Wave), of two tones, the I/O data
digital loopback and the I/Q data loopback.
Figure 68: Modem FD general menu
Figure 69: Modem Tx general menu
Figure 70: Modem Rx general menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the modem menu.
Checkbox Override 1 tone to enable the single tone generation (1 MHz + link frequency); this
setting is not maintained in case of reset of the equipment.
Checkbox Override 2 tone to enable the two tones test signal generation this setting is not
maintained in case of reset of the equipment.
Checkbox IQ Dig. LB to enable data loopback at modem output.
Checkbox Data Dig. LB to enable data loopback at modem input.
5.5.4 Modem configuration menu.
The modem configuration menu let the user to access to the configuration files database.
The modulator and the demodulator sections can be programmed asymmetrically and the actual status can
be monitored in the modem general menu, par. 5.5.3.
REBLE310 ODU Microwave Link
Page 34 of 70 Version 1.1
Figure 71: Modem FD configuration
menu
Figure 72: Modem Tx configuration
menu
Figure 73: Modem Rx configuration
menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the modem menu.
Modulator configurations database access button .
Demodulator configurations database access button .
BER alarm threshold setting access button .
5.5.5 Modem database menu.
The database menu of the modem configurations is composed of N different pages, where N is the number
of configuration files in the SD card. (max 20 for each section).
Masks are shown in Figure 74 and Figure 75.
Figure 74: Modulator database menu
Figure 75: Demodulator database menu
Active areas:
Directional key “UP” to return to the main menu
Directional keys “LEFT” and “RIGHT” to navigate within the configurations database.
Configuration selection confirmation button .
REBLE310 ODU Microwave Link
Page 35 of 70 Version 1.1
This menu shows 6 parameters that let the user to identify the configuration file univocally.
1. MOD.SCH is the modulation scheme (QPSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, and 256 QAM).
2. BIT RATE is the payload.
3. REED-SOL shows the parameters of the Reed Solomon FEC (forward error correction).
4. BANDWIDTH shows the occupied bandwidth.
5. PTCM shows the code rate for the convolutional (QPSK) or the PTCM (Pragmatic Trellis Coded
Modulation) FEC protection.
6. SYM. RATE is the Symbol Rate value.
Moreover, the menu shows a progressive number that corresponds to the position in the database. In
order to choose a new configuration, it’s necessary to move with directional arrows on button .
The actual configuration is underlined in green characters.
Attention: This operation causes the link interruption and can lead to undesired conditions in case
the same operation is not repeated in the corresponding section of the equipment that receives/transmits
from/to the actual. In order to establish a connection is in fact necessary that the same configuration is
loaded in both equipment, that’s to say in the modulator section of the transmitter and in the demodulator
section of the receiver.
5.6 ODU - Tx menu. The transmitter menu consists of a page that let the user monitor and configure the main parameters of
the transmitting module; the menu is enabled only if the equipment is FD or Tx.
Figure 76: Transmitter menu
Active areas:
Directional key “UP” to return to the main menu
Arrows to increase/decrease the value of the frequency of the transmitter.
Arrows to increase/decrease the value of the transmitter back-off (only if next checkbox is
disabled).
Checkbox for automatic backoff setting.
Checkbox transmitter squelch; this setting is not maintained in case of equipment reset.
Moreover three alarm led icons are available:
REBLE310 ODU Microwave Link
Page 36 of 70 Version 1.1
1. One alarm for the oscillator lock status (in case of unlock, the transmitter is hardware squelched)
2. One alarm for low transmitter output power.
3. One alarm for module temperature > 60°C.
The page shows also temperature and output power measures.
Attention:
The frequency change is instantaneous and this can lead to link interruption and to the generation of out of
band signals, with possible interference on channel utilized by other users.
Not all frequencies are selectable: there’s a module limit (up to 1 GHz agility) and a factory-imposed limit.
For further information please contact the manufacturer.
5.7 ODU - Rx menu. The receiver menu consists of a page that let the user monitor and configure the main parameters of the
receiving module; the menu is enabled only if the equipment is FD or Rx.
Figure 77: Receiver menu.
Active areas:
Directional key “UP” to return to the main menu
Arrows to increase/decrease the value of the frequency of the receiver.
Moreover three alarm led icons are available:
1. One alarm for the oscillator lock status.
2. One alarm for low received signal strength.
3. One alarm for module temperature > 55°C.
The page shows also temperature and received signal strength (RSSI) measures.
Attention:
The frequency change is instantaneous and this can lead to link interruption.
Not all frequencies are selectable: there’s a module limit (up to 1 GHz agility) and a factory-imposed limit.
For further information please contact the manufacturer.
5.8 IDU - Power Supply menu. The Power Supply menu let the user monitor if both supply plug-in modules are active, what kind of
module is installed and if the secondary voltages (+5V and +6V) are correct.
REBLE310 ODU Microwave Link
Page 37 of 70 Version 1.1
Figure 78: Power Supply menu.
Active areas:
Directional key “UP” to return to the main menu
Moreover a general alarm led icon is present, if anyone of the voltage values is not correct.
The upper side of the menu is dynamically filled by the corresponding plug-in module icon; the plug-in
module can be in AC or DC.
Figure 79: DC supply icon, primary position
Figure 80: DC supply icon, secondary position
Figure 81: AC supply icon, primary position
Figure 82: AC supply icon, secondary position
5.9 ODU - Power Supply menu. The ODU Power Supply menu let the user monitor if the primary Voltage +48 V and the secondary voltages
( + 12 V, +5V and +6V ) are correct.
Figure 83: ODU Power Supply menu.
REBLE310 ODU Microwave Link
Page 38 of 70 Version 1.1
Active areas:
Directional key “UP” to return to the previous menu
5.10 Cable Interface - Power menu. The Cable Interface Power menu let the user monitor if the primary Voltage + Vout before the switch, the
related Intensity of electrical current Iout, and the Voltage after the switch. Moreover ii indicates the
secondary voltages ( + 12V, +3.3V ) status.
Figure 84: Cable Interface Power menu.
Moreover it is possible, prior confirmation, to power-down the ODU, and, obviously, also to power up it ,
this time with no need of confirmation.
Figure 85: Cable Interface ODU Power-down Confirmation form.
Active areas:
Directional key “UP” to return to the previous menu
Directional keys “LEFT” and “RIGHT” to navigate within the cable interface database.
ODU Power button to power-down-power-up the ODU
5.11 Cable Interface - Signal menu. The Cable Interface Signal menu let the user monitor the communication between IDU and ODU.
In this form the user is informed about:
temperatures of the Cable Interfaces
version of the firmware used by the Cable Interfaces
REBLE310 ODU Microwave Link
Page 39 of 70 Version 1.1
two levels of received Signals (in dBm)
estimation of the Quality of the Signals ( 0 means OK )
Figure 86: Cable Interface Signal menu.
Active areas:
Directional key “UP” to return to the previous menu
Directional keys “LEFT” and “RIGHT” to navigate within the cable interface database.
6 WEB interface. The REBLE310-ODU provide a WEB interface for a simple and very user friendly equipment monitoring and
setting.
Connection to the Web Server is performed through the RJ-45 connector located in the front panel; with a
Web Browser (such as Internet Explorer, Mozilla Firefox, Google Chrome, Opera, Safari..) it’s possible to
remotely or locally control the status of the REBLE310-ODU and verify its performances, just writing its IP
address. To control the IP address, please refer to par. 5.3.4.
Figure 87: First page Web interface.
Figure 87 shows the first page of the Web interface, that invite the user to digit an access password.
Attention:
Read and Write password is evviva.
REBLE310 ODU Microwave Link
Page 40 of 70 Version 1.1
Read only password is readit.
After login, the system opens automatically the main page, which is different depending on the equipment
type (FD, TX, RX).
Active areas are shown by the change of the mouse cursor and clicking on them it’s possible to access to
the system sub-blocks.
Figure 88: Main Web interface page.If you click on ‘IDU’ you’ll have :
Figure 89: WEB IDU Main page
REBLE310 ODU Microwave Link
Page 41 of 70 Version 1.1
Whereas, clicking on Cable :
Figure 90: Web Cable interface.
And clicking on ODU :
Figure 91: WEB ODU Main page - FD
REBLE310 ODU Microwave Link
Page 42 of 70 Version 1.1
Figure 92: WEB ODU Main page – Tx
Figure 93: WEB OSU Main page – Rx
On the images related to each board, there are alarm indicators shown as “led”, for a fast access to the
faulty blocks.
Figure 94 shows an example when the Power Supply board and the I/O board are in alarm condition.
REBLE310 ODU Microwave Link
Page 43 of 70 Version 1.1
Figure 94: Web IDU Main page, with alarm indication.
REBLE310 ODU Microwave Link
Page 44 70 Version 1.0
6.1 IDU Microcontroller board.
This form is kind of collection of miscellaneous not necessarily related to the microcontroller itself.
Figure 95: IDU Microcontroller WEB Page
REBLE310 ODU Microwave Link
Page 45 of 70 Version 1.1
The microcontroller Web Page is composed of 8 frames:
1. Miscellaneous
2. Networking
3. Temperature
4. Stats
5. Relays
6. Left Fan Control
7. Right Fan Control
8. Traps Management
6.1.1 IDU Microcontroller – Miscellaneous.
Figure 96: Microcontroller Web page - Miscellaneous.
This frame let the user check the general information of the equipment. Following table resume each text
box function. Table 9
uC FW Version Embedded software version
Intf FW Version FPGA modem firmware version
Inventory Inventory code, for customer use,
modifiable clicking on
Description Equipment description
Customer Name Customer name
Equipment PN Equipment Part Number
Equipment Model Commercial code
Equipment SN Equipment Serial Number
REBLE310 ODU Microwave Link
Page 46 of 70 Version 1.1
6.1.2 IDU Microcontroller – Fan control.
Figure 97: Microcontroller WEB page – Left fan control.
Figure 98: Microcontroller WEB page – Right fan control
These frames let the user monitor and configure the functioning of the fans installed in the front panel.
The Automatic checkbox set as automatic the fans driving, whose speed can be read in the box Speed
(rpm); in this case it’s necessary to establish temperature targets for the modules equipped with sensor,
and the system controller will drive the fans in order to maintain the temperatures set by the user.
In case the Automatic checkbox is disabled, on the contrary, the user should set manually the speed in
percentage with the maximum speed, increasing or decreasing the value clicking on the arrows.
The Refresh button let the user to update the frame in case of network congestion.
6.1.3 IDU Microcontroller – Events Log.
REBLE310 ODU Microwave Link
Page 47 of 70 Version 1.1
It shows last 1000 events registered in the system.
Log Enabled It enables the event log
Actual Page Page shown
Row@Page Numbers of rows per page
Delete Older It removes last rows
It allows to cancel all events
Rows Numbers of events registered
Max Maximum numbers of events registered
Auto load It enables the periodical update of the new events
6.1.4 IDU Microcontroller – Networking.
Figure 99: Microcontroller Web page – networking.
Clicking on icon the page shown in Figure 100 will be opened, enabling the user to read and
eventually modify the equipment network parameters.
Ip Address, Net mask and Gateway Address are user modifiable clicking on icons ; the Mac Address is
obviously read only. Moreover, it’s possible to set 4 different IP address as destination of SNMP traps.
REBLE310 ODU Microwave Link
Page 48 of 70 Version 1.1
Figure 100: Network Configuration Web page
6.1.5 IDU Microcontroller – Temperature.
Figure 101: Microcontroller web page – temperature.
This frame let the user monitor the temperature detected by the sensor installed on the microcontroller
board.
6.1.6 IDU Microcontroller – Relays.
Figure 102: Microcontroller WEB page – Relays management.
This frame let the user to give different alarm conditions to the 5 relays whose contacts are available at the
back panel.
REBLE310 ODU Microwave Link
Page 49 of 70 Version 1.1
Clicking on opportune areas identified by icon , the user can access to a page showing all available
alarm conditions. The user should select the desired checkbox to add the variable to the alarm list driving
the relay chosen. Confirm the selection clicking on .
Figure 103: Alarm conditions list page
6.1.7 IDU Microcontroller – Stats.
Figure 104: Microcontroller WEB page – Statistics.
This frame let the user set a time period (from 1 to 10 days) and a sampling time (from 1 s to 120 s) during
which the RSSI and the MSE are recorded in a text file; this file is saved in the SD card and can be recovered
through FTP server without opening the equipment.
The FTP server use is critical and can compromise the system integrity; for this reason there’s a password
which is communicated in case of customer request.
REBLE310 ODU Microwave Link
Page 50 of 70 Version 1.1
6.1.8 IDU Microcontroller – Traps.
Figure 105: Microcontroller WEB page - Traps.
This frame let the user access the traps management; for every available alarm condition is possible to set
the trap priority level from 0 to 4, on the basis of the SNMP protocol.
Figure 106: Microcontroller WEB page – Traps Management.
REBLE310 ODU Microwave Link
Page 51 of 70 Version 1.1
6.1.9 IDU Microcontroller – Configuration and Password Manager
6.1.9.1 Password Manager
ReadOnly , Read-Write , Factory for:
Web
Snmp
Ftp
Display
Passwords should be at least of 6 characters and not longer than 15 characters.
REBLE310 ODU Microwave Link
Page 52 of 70 Version 1.1
6.2 IDU I/O board.
Figure 107: I/O board WEB page, 4 ASI FD case.
REBLE310 ODU Microwave Link
Page 53 of 70 Version 1.1
The I/O board WEB page is composed of different frames depending on the board installed (4ASI, GbE or
STM-1).
At the top is available a frame that let the user enable/disable through checkbox every input and output
channel.
Figure 108: I/O channels enabling/disabling and output frame, GbE and 4 ASI case.
Near this frame you can see a menu suitable to set the bandwidth of each channel.
Figure 109: Channel bitrate settings.
Moreover, a variable number of frames corresponding to each I/O channel are available.
Figure 110: ASI A input frame.
Every frame shows the channel bitrate and 4 icons showing the presence, the lock of PLL and the overrun
and underrun conditions of the data buffers.
REBLE310 ODU Microwave Link
Page 54 of 70 Version 1.1
6.3 ODU Modem board.
Figure 111: Modem FD WEB page.
The modem board WEB page is composed of 4 frames, which show information of either modulator and
demodulator section.
1. Alarms.
2. Measurements.
3. Configurations.
4. Miscellaneous.
6.3.1 ODU Modem – Alarms.
Figure 112: Modem WEB page - Alarms.
This frame shows the alarm conditions of the modem board through led-like icons.
Following table explains the meaning of each one.
REBLE310 ODU Microwave Link
Page 55 of 70 Version 1.1
Table 10
Name Section Configuration Meaning
Timing Loop Modulator FD and Tx Modulator locking status to
incoming data stream.
FPGA Error Modulator and Demodulator All FPGA programming result.
Lock Demodulator FD and Rx Demodulator locking status
to the signal received from
the Rx module.
BER Th. Warning Demodulator FD and Rx The BER before Reed
Solomon measure is higher
than the threshold set by
the user. The indication is to
be considered only if the
demodulator is ‘Lock’.
MSE Th. Warning Demodulator FD and Rx The MSE measure is higher
than the threshold set by
factory.
The indication is to be
considered only if the
demodulator is ‘Lock’. The
threshold varies depending
on the modulation scheme
chosen.
6.3.2 ODU Modem – Measurements.
Figure 113: Modem WEB page - Measurements.
This frame shows the main measures of the modulator and of the demodulator section, conditioned to the
equipment type (FD, Tx, and Rx).
Next table resumes their meaning. Table 11
Name Section Configuration Meaning
Symbol Rate Modulator
FD and Tx Symbol rate value read by the modulator; it should fit to the
configuration parameters.
MSE Demodulator FD and Rx Mean Square Error value.
BER before RS Demodulator FD and Rx Bit Error Rate before Reed Solomon decoder read by the demodulator.
Carrier Offset Demodulator FD and Rx Frequency offset of the received signal compared to the center
REBLE310 ODU Microwave Link
Page 56 of 70 Version 1.1
frequency. An embedded procedure minimizes this value through
continuous monitoring and fine tuning of Rx local oscillator.
AGC Level Demodulator FD and Rx Demodulator Digital Automatic Gain Control level. This measure is not
important for the user.
Data Rate Demodulator FD and Rx Payload of the link.
6.3.3 ODU Modem – Configurations.
Figure 114: Modem WEB page - Configurations.
This frame let the user set the modem parameters and can vary depending on the equipment configuration
(FD, Tx, and Rx).
Clicking on icon the user can access to a further frame letting him set the alarm threshold for BER.
Figure 115: Modem WEB page - BER threshold update
On Clicking on icons and the user access to the database of configurations files for the
modulator and the demodulator. The text box beside these icons indicates the location of the configuration
in use.
Attention:
Changing the modem configuration is an operation that interrupts the link in both directions; be sure that
the amount of data to be carried is lower than the configuration capacity and that passive elements of the
microwave link are conveniently dimensioned for the desired reliability of the connection.
Contact the manufacturer for further information.
REBLE310 ODU Microwave Link
Page 57 of 70 Version 1.1
Figure 116: Modulator configurations database WEB page.
The database shows the general information of each configuration file available and its position in the
database itself (2nd column). The actual configuration is underlined in green characters; if the user wants to
change configuration, he should click on buttons located in the 1st column and confirm clicking on
located at the top of the page.
Figure 117: Modulator configurations database WEB page while changing configuration.
The chosen configuration is underlined in red and at the top of the page is resumed the operation that is
ready to be performed. In the meanwhile it’s also possible to access to the demodulator section, clicking on
the respective TAB in the left upper corner and shown in next figure.
REBLE310 ODU Microwave Link
Page 58 of 70 Version 1.1
Figure 118: Mod and dem selection tab detail.
6.3.4 ODU Modem – Miscellaneous.
Figure 119: Modem WEB page - Miscellaneous.
This frame indicates the general information of the configurations utilized by the modulator and the
demodulator. For simplicity purposes, only the modulation scheme, the occupied bandwidth and the net
payload are shown.
Four further checkbox are available, whose function is explained in next table. Table 12
Override IQ Dig.
Loopback
Data loopback after modem.
Override 1 Tone CW (Continuous Wave) generator, offset 1 MHz from the center frequency; utilized for parabola
aligning and measurement during installation. This setting is an Override, i.e. a setting that is not
stored and is not maintained after equipment reset.
Override 2 Tones Two tones generator, offset 10 and 13 MHz from the center frequency, utilized to evaluate the
intermodulation of amplifying stages. This setting is an Override, i.e. a setting that is not stored
and is not maintained after equipment reset.
Override Data Dig.
Loopback
Data loopback before modem.
REBLE310 ODU Microwave Link
Page 59 of 70 Version 1.1
6.4 ODU Tx board.
Figure 120: Tx board WEB page.
The Tx module WEB page is composed of many frames that let the user monitor and set the transmitter.
6.4.1 ODU Tx – Central Frequency.
Figure 121: Tx WEB page- Central Frequency.
Operating on the arrows it’s possible to modify the transmitter frequency.
Attention:
The frequency change is instantaneous and this can lead to link interruption and to the generation of out of
band signals, with possible interference on channel utilized by other users.
Not all frequencies are selectable: there’s a module limit (up to 1 GHz agility) and a factory-imposed limit.
For further information please contact the manufacturer.
6.4.2 ODU Tx – Power.
Figure 122: Tx WEB page - Power.
REBLE310 ODU Microwave Link
Page 60 of 70 Version 1.1
The Automatic checkbox manages the power control of the transmitter (or the booster, if present). In
Automatic modality, the backoff is set by the system controller on the basis of the utilized modulation
scheme.(see technical specifications for further information).
Figure 123: Tx WEB page - Power with manual ALC.
In case of manual control, the backoff box reveals a drop-down menu that let the user modify the
transmitter (or the booster, if present) output level, limited by the modulation type for not exceeding
factory limits.
The same frame shows a text box in which the transmitter power detected is indicated; if the booster is
present, the box will suggest seeing the booster page.
6.4.3 ODU Tx – Squelch Ctrl.
Figure 124: Tx WEB page - Squelch Control.
This frame let the user squelch the transmitter; this setting is not maintained in case of equipment reset.
REBLE310 ODU Microwave Link
Page 61 of 70 Version 1.1
6.4.4 ODU Tx – Lock.
Figure 125: Tx WEB page - Lock.
This frame let the user monitor the lock status of the transmitter local oscillator.
6.4.5 ODU Tx – Temperature.
Figure 126: Tx WEB page - Temperature.
This frame let the user monitor the transmitter temperature; the led icon shows if the value is higher than
60°C.
6.4.6 ODU Tx – Part and Serial Number.
Figure 127: Tx WEB page - Part and Serial Number.
This frame visualizes the general information of the module.
6.5 ODU Rx board.
Figure 128: Rx board WEB page.
REBLE310 ODU Microwave Link
Page 62 of 70 Version 1.1
The Rx module WEB page is composed of many frames that let the user monitor and set the receiver.
6.5.1 ODU Rx – Central Frequency.
Figure 129: Rx WEB page - Central Frequency.
Operating on the arrows it’s possible to modify the transmitter frequency.
Attention:
The frequency change is instantaneous and this can lead to link interruption.
Not all frequencies are selectable: there’s a module limit (up to 1 GHz agility) and a factory-imposed limit.
For further information please contact the manufacturer.
6.5.2 ODU Rx – RSSI.
Figure 130: Rx WEB page - RSSI.
The RSSI (Received Signal Strength Indication) frame let the user see the received signal level and verify if
this level is too low for the chosen modulation scheme.
6.5.3 ODU Rx – Lock.
Figure 131: Rx WEB page - Lock.
This frame let the user monitor the lock status of the transmitter local oscillator.
REBLE310 ODU Microwave Link
Page 63 of 70 Version 1.1
6.5.4 ODU Rx – Temperature.
Figure 132: Rx WEB page - Temperature.
This frame let the user monitor the receiver temperature; the led icon shows if the value is higher than
55°C.
6.5.5 ODU Rx – Part and Serial Number.
Figure 133: Rx WEB page - Part and Serial Number.
This frame visualizes the general information of the module.
6.6 ODU Microcontroller. This frame let the user read the ODU environmental temperature and the same kind of information seen on
the microcontroller IDU, but referred to the ODU.
Figure 134: ODU uc Infoes.
6.7 ODU Power Supply. This frame let the user monitor the power supplies of the ODU.
REBLE310 ODU Microwave Link
Page 64 of 70 Version 1.1
Figure 135: ODU Power Supply.
6.8 Cable Interface. This frame let the user monitor the communication between IDU and ODU.
Figure 136: ODU Cable Infoes.
The Cable Interface Power menu let the user monitor if the primary Voltage Vout before the switch, the
related Intensity of electrical current Iout, and the Voltage Vout after the switch. Moreover ii indicates the
secondary voltages ( + 12V, +3.3V ) status.
The Cable Interface Signal menu let the user monitor the communication between IDU and ODU.
In this form the user is informed about:
temperatures of Cable Interfaces
version of the firmware used by Cable Interfaces
two levels of received Signals (in dBm)
estimation of Quality of the Signals ( 0 means OK )
You can use the button to power-down or power-up the ODU. In case of shut-down a
confirmation form will be proposed:
REBLE310 ODU Microwave Link
Page 65 of 70 Version 1.1
Figure 137: ODU Power Down confirmation.
If, in contrary case, you are going to power-up the ODU, the command will be executed with no need of
confirmation.
7 Panels.
7.1 Front Panel.
Figure 138: Front panel
Table 13
1 Not available
2 Not available
3 Left Fan
4 Led ON
5 General Alarm led
6 RJ-45 connector for Ethernet 10/100 Management
7 TFT
8 6 buttons keypad
9 Right fan
10 Not available
11 Not available
7.2 Back Panel. The back panel is composed of the rear side of the supply modules, of the I/O panel (depending on the
board installed) and of the cable interface panel.
1
2
3 4
5
6 7 8 9
10
11
REBLE310 ODU Microwave Link
Page 66 of 70 Version 1.1
Figure 139: IDU back panel – cable interface.
7.2.1 I/O Panels.
STM-1 INTF version.
Figure 140: STM-1 interface version back panel.
4 ASI INTF version.
Figure 141: 4 ASI interface version back panel.
GbE INTF version.
LEMO Connector for IDU-ODU connection Switch on/off of the ODU: keep
pushed for 3 sec and wait for 3 sec more to see effect.
Led indication for 48V presence at the LEMO connector
REBLE310 ODU Microwave Link
Page 67 of 70 Version 1.1
Table 14
AUX Connector pinout
1 Relay 5 NO contact
2 TX 232 EXT
3 GND
4 Relay 2 NO contact
5 ISP
6 +5V
7 Analog voltage input
8 -
9 RX 232 EXT
10 COM Relay
11 Relay 1 NO contact
12 Relay 3 NO contact
13 Relay 4 NO contact
14 Analog voltage output
15 -
8 Maintenance. The equipment maintenance depends on the alarms detected through user interface or opportune
instrumentation.
It’s possible to replace the AC/DC or DC/DC supply eventually damaged and the fans located in the front
panel. For other modules, in case of failure, the shipment to the manufacturer is required.
8.1 Fan replacing. The fan replacing is required in case of related alarm (see par. 5.3.2, 5.3.3, 6.1.2) or in case of evident
blockage of fans due to dust and/or other objects. The replacing action can be “hot”, let’s say it’s not
necessary to switch off the equipment.
Figure 142: Left fan
REBLE310 ODU Microwave Link
Page 68 of 70 Version 1.1
To replace a fan, please follow this procedure:
1. Remove with a screwdriver the 4 fixing screws .
2. Extract the faulty fan.
3. Detach the supply connector.
4. Replace the fan.
The sequence of operations is shown in following pictures.
REBLE310 ODU Microwave Link
Page 69 of 70 Version 1.1
Figure 143: Left fan screws removal - 1.
Figure 144: Left fan screws removal - 2.
Figure 145: Left fan screws removal - 3.
Figure 146: Left fan screws removal - 4.
8.2 Power supply replacing. Power supply module replacing is necessary in case of failure, revealed by the user interface.
The operations to be done are:
1. Remove the supply cable from the faulty module.
2. Remove the two screws fixing the module to the chassis.
3. Extract the supply module, with the help of the handle.
4. Insert the new module, with the help of the aluminum guide for a good alignment.
5. Fix the module to the chassis with two screws.
6. Connect the supply cable.
7. Verify the good functioning through the user interface.
The sequence of operations is shown in following pictures.
Figure 147: AC supply cable removal.
Figure 148: Fixing screws removal.
REBLE310 ODU Microwave Link
Page 70 of 70 Version 1.1
Figure 149: Module extraction.
Figure 150: Module insertion.