ReaMetrix Hiv Reagent Portfolio

12
© 2008 Reametrix, Inc. All rights reserved. Management of HIV Infection in Resource Poor Settings Accurate & Affordable Reagent Alternatives

description

ReaMetrix HIV Reagents

Transcript of ReaMetrix Hiv Reagent Portfolio

Page 1: ReaMetrix Hiv Reagent Portfolio

© 2008 Reametrix, Inc. All rights reserved.

Management of HIV Infection in Resource Poor Settings

Accurate & Affordable Reagent Alternatives

Page 2: ReaMetrix Hiv Reagent Portfolio

2© 2008 Reametrix, Inc. All rights reserved.

HIV in India – Current Status

HIV Prevalence rate in India 0.36% 2.5 Million HIV Infections

By year 2010, estimates indicate that there will be between 8-15 million HIV infected individuals

Management of HIV InfectionProviding Anti Retroviral therapy (ART)Immunophenotyping

CD4 T-Lymphocyte Count

Viral Load Assay – PCR – quantitate virus levels in blood

CD4 counts are the single most important criteria to guide clinical decision-making on

when to use ART

Page 3: ReaMetrix Hiv Reagent Portfolio

3© 2008 Reametrix, Inc. All rights reserved.

ReaMetrix Solutions for CD4 EnumerationDry-Tri T-STAT CD3483 color single tube reagent for open flow Cytometers eg. BD FACScan ™, BD FACSCalibur ™, BC EPICS XL™)

Dry-Tri T-STAT CD34453 color single tube reagent for open flow Cytometers(eg. BD FACScan™, BD FACSCalibur™, BC EPICS XL™)

ReaPan 348454 color single tube reagent for open Flow Cytometers(eg. BD FACSCalibur™)

Rea T count2 color dual tube reagent for FACScount™ Platform

ReaPan 34G-38G2 Color dual tube reagent for the Guava™ Platform

Page 4: ReaMetrix Hiv Reagent Portfolio

4© 2008 Reametrix, Inc. All rights reserved.

ReaMetrix Assay Reagent Characteristics Methodology

Absolute CD4 testing by flow Cytometry – gold standard method

Employ simple Lyse/no wash protocol - single platform technology

Convenience Provided as a ready to use format. No additional dispensing

Unitized formPre-dispensed reagents in unitized form – reduces pipetting

errors

Stability & storageDried down reagents – do not require cold storage. No

aggregation of antibodies & beads in dried form

Simplified work flowMinimal hand on time - just require sample pipetting, reduced

steps

Page 5: ReaMetrix Hiv Reagent Portfolio

5© 2008 Reametrix, Inc. All rights reserved.

ReaMetrix Assay Reagent Characteristics

Accurate & reproducibleWorkshop approved antibody clones – provide excellent

Analytical Specificity & Analytical Sensitivity Extensively validated reagents in various private & public labs

in India

Sample stabilityProcessed samples can be stored for up to 7 days prior to analysis (CV = 5.7%).

AffordableAll of these attributes without compromising affordability

Technical supportReaMetrix provides training on Cytometer and reagentReaMetrix provides technical support online & through personal

visits

Page 6: ReaMetrix Hiv Reagent Portfolio

6© 2008 Reametrix, Inc. All rights reserved.

Reagents are suitable to run on open flow cytometers such as BD FACScan, BD FACSCalibur, Beckman Coulter EPICS-XL etc.

Reagents supplied in Dry, Unitized Format

Dry-Tri T-STAT CD348

3 color single tube reagentAnti CD4 – Atto488* (FITC eq. dye)Anti CD8 – R-PEAnti CD3 – R-PE-Dy649* (Cy5 eq. dye)

Provides absolute counts (Cells/µL) of CD3+, CD4+, CD8+ Cells & CD4/CD8 Ratio Validated with commercial reagents at NARI, YRG CareCE Marked reagent

* Dyes qualified by ReaMetrix to assure superior performance

Page 7: ReaMetrix Hiv Reagent Portfolio

7© 2008 Reametrix, Inc. All rights reserved.

Reagents are suitable to run on open flow cytometers such as BD FACScan, BD FACSCalibur, Beckman Coulter EPICS-XL etc.

Reagents supplied in Dry, Unitized Format

Dry-Tri T-STAT CD3445

3 color single tube reagentAnti CD4 – Atto488* (FITC eq. dye)Anti CD3 – R-PE-Dy649* (Cy5 eq. dye)Anti CD45 – R-PE

Provides absolute counts (Cells/µL) of Absolute Lymphocyte Count (ALC), CD3+, CD4+, % CD4 CountsValidated with commercial reagents at leading path labs in IndiaSuited for aged blood samples

* Dyes qualified by ReaMetrix to assure superior performance

Page 8: ReaMetrix Hiv Reagent Portfolio

8© 2008 Reametrix, Inc. All rights reserved.

Reagents supplied in Dry, Unitized Format

ReaPan 34845

44 color single tube reagent, Anti CD4 – APC Anti CD8 – R-PEAnti CD3 – Atto488* (FITC eq. dye)Anti CD45 – PerCP

Provides absolute counts (Cells/µL) of ALC, CD3+, CD4+, CD8+ Cells, % CD4 & CD4/CD8 Ratio Validated with BD multiTEST 4 color reagent at leading path. Lab in India.Suited for aged blood samplesDesigned for BD FACSCalibur dual laser flow CytometerCE marked * Dyes qualified by ReaMetrix to assure superior

performance

Page 9: ReaMetrix Hiv Reagent Portfolio

9© 2008 Reametrix, Inc. All rights reserved.

Reagents supplied in Dry, Unitized Format

Rea T-Count Reagent

Rea T-count CD3/CD4 & CD3/CD8 reagentagentDesigned for BD FACSCount flow CytometerAvailable as 2 color dual tube reagent for

CD3+, CD4+, CD8+, CD4/CD8 ratio estimation

Available as 2 color single tube reagent for

CD3+, CD4+ estimation

Alternative for FACSCount reagent Reagent validated at

National HIV Immunology laboratory, CanadaNational HIV Immunology laboratory, Canada

ZimbabweZimbabwe

Page 10: ReaMetrix Hiv Reagent Portfolio

10© 2008 Reametrix, Inc. All rights reserved.

Reagents supplied in dry, unitized format

ReaPan Reagents for the Guava Platform

ReaPan 34G2 color single tube reagent Provides absolute counts (Cells/µL) of CD3+, CD3+CD4+ counts

ReaPan 34G & 38G2 color single dual reagentProvides absolute counts (Cells/µL) of CD3+, CD3+CD4+ & CD3+CD8+ counts

Validated with Guava Reagent at KIMS, Bangalore

Page 11: ReaMetrix Hiv Reagent Portfolio

11© 2008 Reametrix, Inc. All rights reserved.

Summary…

ReaMetrix supplies all reagents with ReaLyse, a buffer for lysing and fixing samples or ReaFix, a buffer for fixing samples after staining

ReaMetrix has the capability to develop CD4+ enumeration solutions for any flow cytometer platform.

ReaMetrix can customize solutions as per your need.

Work is in progress for reagent development for other platforms.

Page 12: ReaMetrix Hiv Reagent Portfolio

12© 2008 Reametrix, Inc. All rights reserved.

Manufactured by ReaMetrix India Pvt. Ltd.50-B, II Phase, Peenya Industrial Area

Peenya, Bangalore 560058, IndiaPh: +91-80-28378693/5, Fax: +91-80-

41172451E-mail: [email protected]

www.reametrix.com

Further details: