Presents
REAC IMPOSSIBLE I
Presented by
Hank Vanderbeek, MPA, CMI
Wednesday, March 27, 2014, 1:00 PM EST
www.REAC1.com
603-867-REAC (7322)
1Copyright 2013, REAC Property Consultants, LLC
Training Agenda
1:00 PM – 1:05 PM Mission, Goal, Conduct
1:05 PM – 1:30 PM Inspection Protocol
2
1:30 PM – 1:35 PM Important Deficiencies
1:35 PM – 1:45 PM Scoring Overview
603-867-7322, www.REAC1.com
1:55 PM – 2:00 PM Questions
1:45 PM – 1:55 PM New Rules Impact
The Real Estate Assessment Center's (REAC) mission is to:
• Help ensure that subsidized housing is decent, safe and sanitary & in good repair
• Provide and promote the effective use of accurate, timely and reliable information for assessing property condition
The Mission
3603-867-7322, www.REAC1.com
The Goal
The goal is assign a score to the property condition based on the data collected by the
Inspector by:
Accurately measuring physical
condition
Being objective & consistent –
“snapshot in time”
Following the UPCS protocol
4603-867-7322, www.REAC1.com
The Uniform Physical Condition Standards (UPCS) are the foundation of REAC’s Inspection Program.
o Creates the structure for the inspection.
o Establishes standardized definitions for inspectable items.
o Provides a uniform, objective protocol for training inspectors on all property types.
5603-867-7322, www.REAC1.com
The Goal (Cont.)
Maintains professional conduct and demeanor – no “gotcha on that.”
Displays the HUD-issued photo
Dresses appropriately
Aware of cultural differences
Does not make promises about results
CODE OF CONDUCT
6603-867-7322, www.REAC1.com
Defers resident to the property rep.
No conflicts of interest
Opinions about the property – No! No!
Does not bring weapons
Does not invade a resident’s privacy
CODE OF CONDUCT (Cont.)
7603-867-7322, www.REAC1.com
Does not disclose any information to a third party about the inspection results
Does not utilize property offices to conduct personal business
Subjectivity, negligence and gaming
CODE OF CONDUCT (Cont.)
8603-867-7322, www.REAC1.com
SUBJECTIVITY
Making personal judgments about the condition of a property or allow their personal biases to affect how they inspect, e.g.:
• Allowing bad property management to affect the assessment
• Allowing bad housekeeping to affect the assessment
• Allowing negative opinions about the property affect the assessment
9603-867-7322, www.REAC1.com
CODE OF CONDUCT (Cont.)
NEGLIGENCE
Does not follow the Protocol to reduce the time/effort required to inspect a property
• Not thoroughly inspecting items to truly determine their condition
GAMING
When inspectors perform illicit activities in an attempt to cheat the system
• Accepting bribes or favors
10603-867-7322, www.REAC1.com
CODE OF CONDUCT (Cont.)
Decent, safe, sanitary and in good repair
UPCS - Objective & Subjective, Consistent, Comprehensive
Professional and well organized
Take charge of the inspection and set the tone
Summary
11603-867-7322, www.REAC1.com
1Inspector
recv’s inspection
1Inspector
recv’s inspection
Downloads propertyprofile
Downloads propertyprofile
2Confirms
inspection Confirms
inspection
3
Meets with property representative
Meets with property representative
4 5Verify/updates property
profile info
5Verify/updates property
profile info
6Visually verify/
Updatesbuilding info
6Visually verify/
Updatesbuilding info
Samplegenerated Sample
generated
7Property InspectedProperty Inspected
8
8 STEP INSPECTION PROTOCOL
13603-867-7322, www.REAC1.com
Inspection is awarded to winning bidder via Reverse Auction Program, or
Contractor/servicing mortgagee assigns inspection to inspector, or
REAC employee (Quality Assurance Specialist) is assigned the inspection
STEP 1: Inspector Receives InspectionIN
SP
EC
TIO
N S
ET
UP
PH
AS
EIN
SP
EC
TIO
N S
ET
UP
PH
AS
E
14603-867-7322, www.REAC1.com
Inspector downloads Property Profile from the REAC Web site to the UPCS software on their laptop.
The Property Profile information is verified while on site.
STEP 2: Property Profile Downloaded
15603-867-7322, www.REAC1.com
INS
PE
CT
ION
SE
T U
P P
HA
SE
INS
PE
CT
ION
SE
T U
P P
HA
SE
REAC Inspector contacts the property rep
o Must contact property within 20 days of getting inspection
o Gives property an inspection date & 3 alternate dates for inspection
o Inspections must complete inspection within 120 days of winning the inspection
STEP 3: Confirms Inspection – Date & Time
16603-867-7322, www.REAC1.com
INS
PE
CT
ION
SE
T U
P P
HA
SE
INS
PE
CT
ION
SE
T U
P P
HA
SE
Inspector sends notification letter to have available for inspection:
Copy of document notifying residents Total buildings and units in each building and BRs Applicable certificates (elevators, boilers, etc) Occupancy rate Rent roll by building Site map or plot of property (if available) Area measures for parking lots/driveways/roads and
walkways/steps (fences) Bed bugs list
STEP 3: Confirm Inspection (Cont.)
17603-867-7322, www.REAC1.com
INS
PE
CT
ION
SE
T U
P P
HA
SE
INS
PE
CT
ION
SE
T U
P P
HA
SE
Inspector must be on time to conduct the inspection - r e s p e c t !
If the weather prevents the inspector from arriving at the property, they request approval from REAC to declare the inspection “unsuccessful.”
18603-867-7322, www.REAC1.com
STEP 3: Confirm Inspection (Cont.)
Severe Weather Advisory in effect – cancel inspectionINS
PE
CT
ION
SE
T U
P P
HA
SE
INS
PE
CT
ION
SE
T U
P P
HA
SE
o The inspector should:
Explain the purpose of the inspection To objectively record the condition of the property
Verify that residents were given notice
Explain sampling process Generates random sample of units to inspect.
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
STEP 4: Inspector Meets with Property Rep
19603-867-7322, www.REAC1.com
o The Inspector must:
Verify/update before the inspection begins
Verify rent roll to confirm proper building/unit count
Verify list of units relative to disability (504/FHA/ADA)
Verify occupancy rate
STEP 4: Meet with Property Rep (Cont.)
20603-867-7322, www.REAC1.com
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
o The Inspector must:
Obtain area measures
Ask if scattered site • 1 to 4 Unit Bldg• View all pre-inspection • View only location with sample unit/bldg at inspn
Tell you needs to be accompanied by property representative at all times.
STEP 5: Verify/Update Property Profile
21603-867-7322, www.REAC1.com
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
o The Inspector must obtain:
Participant name = individuals or organizations
Participant role (e.g., site manager, owner, etc.)
Participant address, telephone, fax, email
3 participants• PHA - must include Executive Director.• MF - must include Owner and the Mgt Agent
STEP 5: Verify/Update Property Profile (Cont.)
22603-867-7322, www.REAC1.com
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
o The Inspector must:
Verify the existence of applicable certificates.• Checks expiration date to ensure it is current
Inspect Lead-Based Paint Disclosure Form and Lead-Based Paint Inspection Report
• Prior to 1978 construction • Checks 5 resident rent folders• No point deduction if no/expired certificate
23603-867-7322, www.REAC1.com
STEP 5: Verify/Update Property Profile (Cont.) P
RE
- IN
SP
EC
TIO
N P
HA
SE
PR
E-
INS
PE
CT
ION
PH
AS
E
o Inspectors must visually verify:
Building name and address Building type Building construction year (year built) Total number of units in each building
o Failure to validate building information accurately could result in an inaccurate count of buildings and units
Building and unit counts are used to generate the inspection sample
STEP 6: Visually Verify Building Info
24603-867-7322, www.REAC1.com
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
603-867-7322, www.REAC1.com 25
STEP 6: Visually Verify Building Info (Cont.)
Building Definition - A building is defined as any structure that has a:
1. permanent foundation
2. enclosed on all sides
3. one utility such as electric, gas, water or sewer.
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
Common Building – A detached non-residential structure.
Duplex – A detached residential structure with two units.
Low-Rise/Garden Apt – A structure with 2.5 or less floors with a common hall entrance.
Mid/High-Rise Apartments – A structure with 3 or more floors with or without elevators.
Row/Town House – A single unit structure connected to a similar structure by a common sidewall with individual exterior entrance.
Single Family House – A detached structure with 1 unit.
26603-867-7322, www.REAC1.com
STEP 6: Visually Verify Building Info (Cont.)P
RE
- IN
SP
EC
TIO
N P
HA
SE
PR
E-
INS
PE
CT
ION
PH
AS
E
UPCS software generates sample Statistically valid random sample
Produces a sample that reflects what would have been recorded if all buildings/units were inspected
Error rate projected to all buildings/units
Incorrect sampling invalidates the inspection
STEP 7: Sample Generation
27603-867-7322, www.REAC1.com
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
603-867-7322, www.REAC1.com 28
STEP 7: Sample Generation (Cont.)
Inspector can’t let property owner alter sample units or alternate selection order.
Property cannot provide a list of samples prior to inspection.
Inspector cannot deviate from inspection protocol.
PR
E-
INS
PE
CT
ION
PH
AS
EP
RE
- IN
SP
EC
TIO
N P
HA
SE
SITEFencing/GatesGroundsMailboxes/Project SignsMarket AppealParking Lots/Driveways/RoadsEtc.
SITEFencing/GatesGroundsMailboxes/Project SignsMarket AppealParking Lots/Driveways/RoadsEtc.
BUILDINGEXTERIORDoorsFire EscapesFoundationsLightingRoofsWallsEtc.
BUILDINGEXTERIORDoorsFire EscapesFoundationsLightingRoofsWallsEtc.
BUILDINGSYSTEMSDomestic WaterElectrical SystemElevatorsEmergency PowerFire ProtectionHVACEtc.
BUILDINGSYSTEMSDomestic WaterElectrical SystemElevatorsEmergency PowerFire ProtectionHVACEtc.
COMMON AREASBasement/ Garage/CarportCommunity RoomDay CareHalls/Corridors/ StairsEtc.
COMMON AREASBasement/ Garage/CarportCommunity RoomDay CareHalls/Corridors/ StairsEtc.
UNITBathroomCall-for-AidCeilingDoorsElectrical SystemFloorsHot Water HeaterKitchenEtc.
UNITBathroomCall-for-AidCeilingDoorsElectrical SystemFloorsHot Water HeaterKitchenEtc.
UPCS INSPECTABLE ITEMS
29603-867-7322, www.REAC1.com
STEP 8: Property Inspection PhaseIN
SP
EC
TIO
N P
HA
SE
INS
PE
CT
ION
PH
AS
E
InspectableItem
ObservedDeficiency (OD)
No Observed Deficiency (NOD)
Not Applicable(NA)
Level 1
Level 2
Level 3
- or -
- or -
Deficiency DefinitionsDeficiency Definitions
30603-867-7322, www.REAC1.com
STEP 8: Property Inspection Phase (Cont.)IN
SP
EC
TIO
N P
HA
SE
INS
PE
CT
ION
PH
AS
E
Site is the area surrounding the building(s)• Fencing and Gates, Grounds, Mailboxes, etc.
Each defect is worth a LOT of points
Inspected at any time during the inspection
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
STEP 8: Property Inspection Phase (Cont.)
31603-867-7322, www.REAC1.com
SITE
1. Building Exteriors – walls, roof, foundation, fire escapes, lighting
2. Building Systems - domestic water, HVAC
3. Common Areas - areas within each building that are used by more than one resident or property administration.INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
32603-867-7322, www.REAC1.com
BUILDINGS
STEP 8: Property Inspection Phase (Cont.)
A sample unit is declared uninspectable: Occupant refusal Bedbugs Offline Altered Vacant units
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
33603-867-7322, www.REAC1.com
STEP 8: Property Inspection Phase (Cont.)
UNITS
Multifamily housing properties:• Vacant units at properties
with 15% or more total vacant units (85% occ) are inspected
• Vacant units at properties with less than a 15% vacancy rate are not inspected
• All vacant units are verified
Public housing properties:• Vacant units are not be
inspected.
34603-867-7322, www.REAC1.com
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
VACANT UNITS
STEP 8: Property Inspection Phase (Cont.)
For nursing homes, group homes, and assisted living facilities, any room with a bed(s) is a client room.
• Client rooms are inspected as dwelling units.
• Kitchens, dining areas, community areas, etc., inspected as common areas.
35603-867-7322, www.REAC1.com
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
CLIENT ROOMS/UNITS
STEP 8: Property Inspection Phase (Cont.)
• Air Quality• Electrical Hazards• Elevator • Flammables• Garbage & Debris• Trip Hazards• Infestation
36603-867-7322, www.REAC1.com
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
STEP 8: Property Inspection Phase (Cont.)
H&S HAZARDS
Two Types: Fix later
1) Propane, natural, or methane gas
2) Exposed wires or open electrical panels
3) Water leaks on or near electrical equipment
4) Blocked or unusable emergency or fire exits
5) Blocked fire escapes or ladders
6) Missing or misaligned chimney for gas-fired water heater/HVAC
7) Window security bars preventing exit
8) Expired fire extinguishers
9) Inoperative/missing smoke detectors
37603-867-7322, www.REAC1.com
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
STEP 8: Property Inspection Phase (Cont.)
EXIGENT H&S HAZARDS
Fix Now
For Public Housing properties, life-threatening deficiencies must be corrected and/or abated within 24 hours and reported to the HUD field office within 3 business days.
For Multifamily Housing properties, life-threatening deficiencies must be mitigated immediately and reported to the HUD field office within 3 business days.
38603-867-7322, www.REAC1.com
STEP 8: Exigent CorrectionsIN
SP
EC
TIO
N P
HA
SE
INS
PE
CT
ION
PH
AS
E
Notification of Exigent and Fire Safety Hazards Observed form.
Property can refuse to sign
A copy of the form, signed by the inspector, is left with property representative.
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
39603-867-7322, www.REAC1.com
STEP 8: Property Inspection Phase (Cont.)
EXIGENT H&S HAZARDS
Fix Now
Inspector MUST CALL OUT all deficiencies & the severity level
• Might inspect neighbor’s fence, city sidewalk or city roads
• Can’t ask questions
• Can’t get clarification
• Can’t note location of defects
• Can’t take pictures of “defects”
• Not using Professional Common Sense40603-867-7322, www.REAC1.com
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
STEP 8: Property Inspection Phase (Cont.)
603-867-7322, www.REAC1.com 41
INS
PE
CT
ION
PH
AS
EIN
SP
EC
TIO
N P
HA
SE
REAC Compilation Bulletin:
G. Professional Common Sense
Professional common sense is to be applied in conjunction with REAC guidance. This is a common sense approach that inspectors are to use when conducting inspections. It means exercising sound, practical, and prudent judgment based on the REAC inspection training and the inspector’s experience.
STEP 8: Property Inspection Phase (Cont.)
603-867-7322, www.REAC1.com 42
STEP 8: Property Inspection Phase (Cont.)IN
SP
EC
TIO
N P
HA
SE
INS
PE
CT
ION
PH
AS
E
Seek clarification
Take pictures & notes
Ask questions
Remain calm
“STAR”
603-867-7322, www.REAC1.com 43
STEP 8: Property Inspection Phase (Cont.)IN
SP
EC
TIO
N P
HA
SE
INS
PE
CT
ION
PH
AS
E
Problems/Issues with REAC Inspector
REAC Technical Assistance Center (TAC) 1-888-245-4860
Clover Rivers-Smith202-475-8559
7:00AM – 8:30PM EST
Inspection protocol is designed to:
• Standardize the inspection process• Provide consistent, objective/factual inspection data
Adherence to the protocol is critical for:
• Accurate physical assessments• Generating a valid sample
Remember “S T A R”
Problems with REAC Inspector – call REAC immediately
REAC INSPECTION PROTOCOL SUMMARY
44603-867-7322, www.REAC1.com
Top 10 Deficiencies
Items If Corrected Significantly Affects Score – Varies property to property
1. Water Heater/Boilers 2. Hot Water Heater Chimneys 3. Baseboard Covers4. Mold/Mildew5. Electrical Covers6. Breaker Panel Ports7. Door Seals8. Door Hardware9. Egress Doors & Windows10. Trip Hazards - Exterior
46603-867-7322, www.REAC1.com
Definition: Missing Pressure Relief Valve (Domestic Water) - L3
1. Water Heater/Boilers – Water heater Pressure Relief Valve discharge pipes do not extend to within 18 inches of the floor, or are missing.
47603-867-7322, www.REAC1.com
Definition: Misaligned Chimney/Ventilation Systems (Domestic Water) - L3
2. Hot Water Heater Chimney – Vent stacks on gas operated water heaters or furnaces are loose or missing.
48603-867-7322, www.REAC1.com
3. Baseboard Covers – Covers on baseboard heaters are missing
Definition: Convection/Radiant Heat System Covers Missing/Damaged (HVAC) - L3 Health and Safety - Hazards/Sharp Edges – L3 Health and Safety - Other/Possible Burn Hazard – L3 No points deducted
49603-867-7322, www.REAC1.com
Definition: Evidence of Mold/Mildew – L1 4 sq”- 1 sq’ and L3 > 1 sq’
4. Mold/Mildew – Evidence of Mold/Mildew in Bathroom Tub Area
50603-867-7322, www.REAC1.com
Definition: Missing Covers (Electrical System) - L3
5. Electrical Covers – Electrical components covers are missing or loose exposing electrical connections
51603-867-7322, www.REAC1.com
Definition: Missing Breakers/Fuses (Electrical System) - L3
6. Breaker Panel Ports – Open breaker ports
52603-867-7322, www.REAC1.com
7. Door Seals – Factory-installed seals on exterior doors, building or unit, are missing or damaged
Definition: Deteriorated/Missing Seals (Entry Only) Unit & Common Areas – L3
53603-867-7322, www.REAC1.com
8. Door Hardware & Surface Damage– Exterior door hardware locks, latches, closures are not operating as designed & holes, paint missing pealing, etc
Damaged Hardware/Locks – L3Damaged Surface – Missing Paint – L3
54603-867-7322, www.REAC1.com
Definition: Blocked Door Egress – L3
9. Egress Doors & Windows – Egress doors have dual-side key locks, inside locks, hasps, etc & windows are blocked
55603-867-7322, www.REAC1.com
Definition: Blocked Window Egress – L3
10. Trip Hazards – Walkways, Roads, Driveways
Definition: Trip hazard on walkway over 3/4” offset/high/gap – L3
56603-867-7322, www.REAC1.com
Top 10 Deficiencies Summary
1. Water Heater/Boilers – Missing or not within 18 inches
2. Hot Water Heater Chimneys – Loose or missing
3. Baseboard Covers – Covers missing
4. Mold/Mildew – Bathroom tub area
5. Electrical Covers – Covers are missing or loose
6. Breaker Panel Ports – Open breaker ports
7. Door Seals – Exterior door seals missing or damaged
8. Door Hardware & Surface – Exterior door hardware not operating
9. Egress Doors & Windows – Egress doors have blocking locks & windows blocked by furniture
10. Trip hazards - Exterior
57603-867-7322, www.REAC1.com
Industry stakeholder input
• Multifamily Housing (Owners / Agents)• Public Housing Authorities• Trade groups• PHA industry groups
HUD information
Trade professionals’ experience
Scoring Development
59603-867-7322, www.REAC1.com
The inspector records the existence and the severity of deficiencies according to objective & subjective criteria
Scoring Based on Objective & Subjective Data
60603-867-7322, www.REAC1.com
• Relative importance (“weights”) were assignedto each physical area, item, and deficiency
• Weights are appliedto the inspection data to compute the score
• The score is based on a 100 point scale
The Scoring Approach
61603-867-7322, www.REAC1.com
Wgt 15% 15% 20% 35% 15% 100%
Property Physical
Condition
Inspection Areas
Site Health & Safety
Deductions
Whole Point DeductionsFrom Final
Score
Building Exterior
Building Systems
DwellingUnits
Common Areas
Building
62603-867-7322, www.REAC1.com
The Scoring Approach (Cont.)
Wgt 15% 15% 20% 35% 15% 100%
Property Physical
Condition
Inspection Areas
Site Health & Safety
Deductions
Whole Point DeductionsFrom Final
Score
Building Exterior
Building Systems
DwellingUnits
Common Areas
Building
Wgt 15% 15% 20% 35% 15% 100%
Wgt 18% 18% 23% 41% 0% 100%
No Common Areas
63603-867-7322, www.REAC1.com
The Scoring Approach (Cont.)
Area Pts x Item Weight x Criticality x Level
Site = 15 Dmgd Ceiling = 4.5% 1 - Slight = 0.5 1 - Least = 0.25Bldg Sys = 20 Chimney = 15.5% 2 - Contrib = 1.25 2 - Severe = 0.50Units = 35 Smoke Det = 0.0% 3 - Imp = 2.25 3 - Most = 1.0Bldg Ext = 15 Trip Haz = 12.5% 4 - Very Imp = 3.0Cmn Areas = 15 Elect Wires = 12.5% 5 - Critical = 5.0
64603-867-7322, www.REAC1.com
The Scoring Approach (Cont.)
Examples
Site, Trip Hazard,- Level 3
Site Scoring
Area Points x Item Weight x Criticality x Level 3 = Points
15 x 12.5% x 2.25 x 1.0 = 4.2
Point Deduction = 4.2
65603-867-7322, www.REAC1.com
Unit, Living Room,Ceiling hole - Level 3
Unit Scoring
Area Points x Item Weight x Criticality x Level 3 = Tot/# Units = Points
35 x 4.5% x 2.25 x 1.0 = 3.5/18 = 0.19
Point Deduction = 0.19
Assuming 18 Sample Units
66603-867-7322, www.REAC1.com
Building Systems, domestic water,misaligned vent - Level 3
System Scoring
Assuming 2 Buildings
Area Points x Item Weight x Criticality x Level 3 = Tot/# Bldgs = Points 20 x 15.5% x 5.0 x 1.0 = 15.5 / 2 = 7.75
67603-867-7322, www.REAC1.com
Point deduction = 7.75
Utility Room, Junction Box, Missing Cover - Level 3
Common Area Scoring
Assuming 1 Building
Area Points x Item Weight x Criticality x Level 3 = Tot/# Bldgs = Points 15 x 10% x 5.0 x 1.0 = 7.5/ 1 = 7.5
68603-867-7322, www.REAC1.com
Point deduction = 7.5
Roof, Membrane Damage,- Level 3
Building Exterior Scoring
Assuming 1 Building
Area Points x Item Weight x Criticality x Level 3 = Tot/# Bldgs = Points 15 x 18.4% x 5.0 x 1.0 = 13.8/ 1 = 13.8
69603-867-7322, www.REAC1.com
Point deduction = 10.0
Units: Smoke Detector,Missing/Inoperable - Level 3
Unit Scoring
Area Points x Item Weight x Criticality x Level 3 = Total /# Units = Points
35 x 0% x 5.0 x 1.0 = 0 / 24 = 0.0
70603-867-7322, www.REAC1.com
Assuming 24 Sample Units
Point Deduction = 0.0
SCORING SUMMARY
71603-867-7322, www.REAC1.com
Industry Stakeholder Input
Scoring is objective and subjective
Area Pts x Item Weight x Criticality x Level = Point Deduction for site or /unit or buildings
603-867-7322, www.REAC1.com 72
NEW RULES
The standards by which REAC inspections are conducted and scored have changed
significantly. Federal Register Vol. 77, No. 154, August 9, 2012,
changed the UPCS.
• September 10, 2012 - Public Housing• January 1, 2013 - Multi-Family
The top eleven (11)
603-867-7322, www.REAC1.com 73
#1 CAPPED POINTS20
12 &
201
3 C
HA
NG
ES
Point loss caps are set at the five (5) inspectable areas:
Site 7.5 points Building Exterior 10 points Common Areas 10 pointsSystems 10 pointsUnits 5 points
Impact - Significant
603-867-7322, www.REAC1.com 74
#2 SITE – FENCES & GATES 20
12 &
201
3 C
HA
NG
ES
Was three deficiencies:
1) Damaged/Falling/Leaning - Level 2 or 32) Holes - Level 1 or 33) Missing Sections - Level 1 or 3
Now two deficiencies:
4) Non-Security Fence/Gate – Level 2
2) Security Fence/Gate – Level 1, 2, 3
Impact - Significant
603-867-7322, www.REAC1.com 75
#3 SITE – PARKING LOTS/DRIVEWAYS/ROADS20
12 &
201
3 C
HA
NG
ES
Impact - Significant
Old Rule – 5% of area affected:
Cracks - Level 2 only Potholes/Loose Materials - Level 2 or 3 Settlement/Heaving - Level 1 or 3
New Rule – 10% of area affected:
Cracks/Settlement/Heaving/Potholes/Loose Material
Level 2: Damage >10%. Level 3: Unusable/ impassable or unsafe for pedestrians and vehicles.
603-867-7322, www.REAC1.com 76
#4 SITE – PONDING PARKING LOTS/DRIVEWAYS/ROADS20
12 &
201
3 C
HA
NG
ES
Old Rule
Level 2 – Water up to 3” on over 5%
Level 3 – Water over 3” over more than 5%
New Rule
Level 2 – Water 1” to 3” > 5%
Level 3 – Water over 3” > 5%
Impact – Minor
603-867-7322, www.REAC1.com77
#5 SITE – PONDING/DRAINAGE20
12 &
201
3 C
HA
NG
ES
Old Rule
Level 2 – Water up to 3” to 5”
Level 3 – Water over 5”
New Rule
Level 2 – Water 3” to 5” > 100 sq’
Level 3 – Water over 5” > 100 sq’ or 20% impassable
Impact – Minor
603-867-7322, www.REAC1.com 78
#6 SITE – RETAINING WALLS 20
12 &
201
3 C
HA
NG
ES
Retaining Walls –Damaged/Falling/Leaning Level 2 has been downgraded to Level 1.
Redefined Level 2 as a Level 1
Missed opportunity
Defect cited same frequency
About 2.5 points to 1.25 points
Impact - Significant
603-867-7322, www.REAC1.com 79
#7 MOLD/MILDEW – AIR QUALITY 20
12 &
201
3 C
HA
NG
ES
Old Rule
Evidence of mold/mildew, such as a darkened area, regardless of the amount = Level 3
New Rule
Evidence of mold or mildew that is 4 sq” to 1 sq’ = Level 1
Evidence of mold/mildew over 1 sq’ = Level 3
Applies to all areas equally - walls, ceilings, & floors
Cited less often
Impact - Significant
603-867-7322, www.REAC1.com 80
#8 WINDOW SCREEN DEFECTS 20
12 &
201
3 C
HA
NG
ES
Now, instead of about .7 points, lose up to 3 points.
Now, windows screens are non-scoring as a Building Exterior defect and a scored item for Common Areas and Units.
Now, missing or deteriorated caulk, seals and/or glazing compound is a Level 1 instead of Level 2.
Impact - Significant
603-867-7322, www.REAC1.com 81
#9 FLOOR COVERING DAMAGE20
12 &
201
3 C
HA
NG
ES Old Rule - Missing/damaged floor covering
included all types of flooring: hardwood, sheet goods, carpet, et cetera.
New Rule - Divided into hard flooring and soft flooring:
• Hard Floor Covering - Missing/Damaged
• Soft Floor Covering - Missing/Damaged
Impact - Minimal
603-867-7322, www.REAC1.com 82
#10 SHARP EDGES - UNIT 20
12 &
201
3 C
HA
NG
ES
Old rule - Points deducted for a sharp edge defect in the Unit for resident owned items, like broken mirrors, picture glass, missing fan covers, et cetera.
New rule - No longer results in point deduction.
Equaled about 35% of the total Unit points
Impact - Significant
603-867-7322, www.REAC1.com 83
#11 RESIDENT FIRE EXTINGUISHERS 20
12 &
201
3 C
HA
NG
ES
Impact - Significant
Old rule - Points deducted for resident fire extinguishers issues: missing or expired, et cetera.
New rule - No longer result in a point deduction.
The point deductions impact was oftentimes significant.
New Rules Summary
84603-867-7322, www.REAC1.com
1) Capped Points – 7.5, 10, 10, 10, 5
2) Fences & Gates – Combined defect
3) Pkng Lots/Driveways/Rds – Combined 10%
4) Ponding Pkng Lots/Driveways/Rds – 1” to 3”
5) Site Ponding/Drainage – Over 100 sq’
6) Retaining Walls – Level 1
7) Mold/Mildew – Level 1
8) Window Screen Defects - 0.7 to 3.0
9) Floor Covering Damage – Soft vs Hard
10) Resident Sharp Edges – No points
11) Resident Fire Extinguishers – No points
603-867-7322, www.REAC1.com85
HUD REAC CONTACT
REAC Inspection Questions/Concerns
REAC Technical Assistance Center (TAC)
1-888-245-4860
7:00AM – 8:30PM EST
www.REAC1.com
603-867-REAC (7322)
87