RAPiD TEST foR All quinolonES AnD fluoRoquinolonES · milk RAPiD TEST foR All quinolonES AnD...

2
MILK RAPID TEST FOR ALL QUINOLONES AND FLUOROQUINOLONES NEGATIVE POSITIVE CTRL TEST Sensitivity Results Visual interpretation of the result by comparing the intensity of the “TEST” line with the one of the “CTRL” line. QUINOSENSOR is a rapid competitive antibody- based assay in dipstick format detecting all relevant (Fluoro)-Quinolones in milk at or below EU maximum residue limits (MRLs). COMPOUNDS LIMITS OF DETECTION (PPB) KIT038 (**) MRL Norfloxacin ≤ MRL - Enrofloxacin ≤ MRL 100 (*) Danofloxacin ≤ MRL 30 Difloxacin ≤ MRL - Marbofloxacin ≤ MRL 75 Sarafloxacin ≤ MRL - Ciprofloxacin ≤ MRL 100 (*) Flumequine ≤ MRL 50 Oxolinic acid ≤ MRL - Lomefloxacin ≤ MRL - Enoxacin ≤ MRL - Benefits 6min VERY FAST ALL (FLUORO)-QUINOLONES (*) Limit for the sum of both compounds. (**) Validation pending. ECOLOGICAL PACKAGING COST-EFFECTIVE USER-FRIENDLY Easily performed on site or in lab. RELIABLE AND ROBUST GENERIC Detection of all relevant (Fluoro)-Quinolones. SENSITIVE Limit of detection below EU MRLs. RAPID Results in 6 minutes.

Transcript of RAPiD TEST foR All quinolonES AnD fluoRoquinolonES · milk RAPiD TEST foR All quinolonES AnD...

mil

k

RAPiD TEST foR All quinolonESAnD fluoRoquinolonES

negative positive

CtRL

test

Sensitivity

ResultsVisual interpretation of the result by comparing the intensity of the “TEST” line with the one of the “CTRl” line.

QUinosensoR is a rapid competitive antibody-based assay in dipstick format detecting all relevant (Fluoro)-Quinolones in milk at or below eU maximum residue limits (MRLs).

CoMpoUndsLiMits oF deteCtion (ppb)

kit038 (**) MRL

norfloxacin ≤ mRl -

Enrofloxacin ≤ mRl 100 (*)

Danofloxacin ≤ mRl 30

Difloxacin ≤ mRl -

marbofloxacin ≤ mRl 75

Sarafloxacin ≤ mRl -

Ciprofloxacin ≤ mRl 100 (*)

flumequine ≤ mRl 50

oxolinic acid ≤ mRl -

lomefloxacin ≤ mRl -

Enoxacin ≤ mRl -

Benefits

6 min

6 min

6 min

6 min

6 min

6 min

6 min

„ VERY FAST „ All (FluoRo)-quinolonES

(*) limit for the sum of both compounds.(**) Validation pending.

„ eCoLogiCaL paCkaging

„ Cost-eFFeCtive

„ �UseR-FRiendLyEasily performed on site or in lab.

„ ReLiabLe and RobUst

„ geneRiCDetection of all relevant (fluoro)-quinolones.

„ sensitivelimit of detection below Eu mRls.

„ RapidResults in 6 minutes.

Reseller

Unisensor s.a.

Zi du DossayRue du Dossay, 3B-4020 Wandre (liège)BElgium

Phone +32 4 252 66 02fax +32 4 252 90 [email protected]

www.unisensor.be

How to use

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

Start HEATSENSOR

HEATSENSOR

1 3

5

2 4

Incubate 6 mInutes

Products ReferenceskiT038 „ quinoSEnSoR mk mRl - 96 pc

APP032 „ HEATSEnSoR DuoAPP039 „ READSEnSoR ESE full CASE

Developed in cooperation with the Spanish National Research Council (CSIC) - Patent Pending.

Mix milk and reagents.

place the vial to heating block.

Close and push “staRt”.

place dipstick to Heatsensor.

interpret results.