RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration...

8
SLIDE FIXED SLIDING WINDOW This drawing is confidential. This drawing and its copyright are the property of or to Trend Windows & Doors and must not be used, disclosed or reproduced in any form whatsoever except as authorised in writing. This drawing must be returned with quotation and/or completion of job as applicable These are only a generic building in details to assist in the construction and installation of Trend Windows and Doors; please contact us for further information or enquiries. Issue Modification Drawing Notice Notice Date Date Revision Drawn BOTANICA RANGE PRODUCT CONFIGURATION A FIRST ISSUE FEB 18 08 02 2018 A P.G. OUTSIDE HEAD SILL JAMB JAMB OUTSIDE F F F 138 138 65 118 65 118 65 115 65 115 35.5 90 63 25 10 88 138 138

Transcript of RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration...

Page 1: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

SLIDE FIXEDSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

BOTANICA

RANGE PRODUCT CONFIGURATION

A FIRST ISSUE FEB 18

08 02 2018

A

P.G.

OUTSIDE

HEAD

SILL

JAMB JAMB

OU

TS

ID

E

FF

F

138 138

65

11

8

65

11

8

65

11

5

65

11

5

35.5

90

63

2510

88

13

8

13

8

Page 2: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

FIXED SLIDE SLIDE FIXEDSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

A FIRST ISSUE FEB 18

08 02 2018

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

A

P.G.

BOTANICA

RANGE PRODUCT CONFIGURATION

JAMB JAMB

OU

TS

ID

E

F F

25

35.5

88

63

117.5 63

25

35

88

13

8

13

8

Page 3: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

SLIDE FIXED SLIDESLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

A FIRST ISSUE FEB 18

08 02 2018

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

A

P.G.

BOTANICA

RANGE PRODUCT CONFIGURATION

JAMB JAMB

OU

TS

ID

E

F

13

8

35.5

90

63

63

25

90

13

8

Page 4: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

FIXED SLIDE FIXEDSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

A FIRST ISSUE FEB 18

08 02 2018

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

A

P.G.

BOTANICA

RANGE PRODUCT CONFIGURATION

JAMB JAMB

OU

TS

ID

E

FF

25

35

88

63 35.5

90

63

25

35

13

8

13

8

Page 5: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

SLIDE FIXEDSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

BOTANICA

RANGE PRODUCT CONFIGURATION

A FIRST ISSUE FEB 18

08 02 2018

A

P.G.

JAMB JAMB

OU

TS

ID

E

F

OUTSIDE

HEAD

SILL

TRANSOM

FF

OU

TS

ID

E

65

11

7.8

138 138

65

11

7.8

65

11

5

25

65

11

5

25

13

38

23

23

38

138138

35.5

89.9

63

25

35

88

13

8

25

38.5

25

51.5

25

38.5

13

8

13

81

38

Page 6: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

BUILDING IN DETAIL - BRICK VENEERSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

BOTANICA

RANGE PRODUCT CONFIGURATION

A FIRST ISSUE APR 18

26 04 2018

A

J.L

138.0

65

.0

65

.0

138.0

36

138.0

10MM MINIMUM

CLEARANCE

HEADER

NO PACKING

TRIMMER

LINING

FLASHING BY BUILDER

HEAD

ARCHITRAVE

PACKING BY BUILDER

FLASHING BY BUILDER

SILL

JAMB

PACKING BY BUILDER

FLASHING BY BUILDER

BRICK SILL

BRICKWORK

Page 7: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

BUILDING IN DETAIL - DOUBLE BRICKSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

BOTANICA

RANGE PRODUCT CONFIGURATION

A FIRST ISSUE APR 18

26 04 2018

A

J.L

FLASHING BY BUILDER

HEAD

SILL

JAMB

STEEL LINTEL

FLASHING BY BUILDER

10MM MINIMUM

CLEARANCE

BRICKWORK

BRICKWORK

BRICKWORK

BRICKWORK

BRICKWORK

BRICKWORK

138.0

65

.0

65

.0

138.0

36

138.0

Page 8: RANGE PRODUCT CONFIGURATION SLIDING WINDOW SLIDE …€¦ · botanica range product configuration afirst issue apr 1826 04 2018 a j.l 138.0 65.0 65.0 138.0 36 138.0 10mm minimum clearance

BUILDING IN DETAIL - CLADDINGSLIDING WINDOW

This drawing is confidential. This drawing and its

copyright are the property of or to Trend Windows &

Doors and must not be used, disclosed or

reproduced in any form whatsoever except as

authorised in writing.

This drawing must be returned with quotation

and/or completion of job as applicable

These are only a generic building in details to

assist in the construction and installation of

Trend Windows and Doors; please contact us

for further information or enquiries.

Issue ModificationDrawing NoticeNotice Date Date

Revision

Drawn

BOTANICA

RANGE PRODUCT CONFIGURATION

A FIRST ISSUE APR 18

26 04 2018

A

J.L

HEAD

SILL

JAMB

CLADDING

FLASHING BY BUILDER

HEADER TRIMMER

NO PACKING

12MM CLEARANCE

CLADDING

TRIM BLOCK BY BUILDER

SILL PLATE

STUD

STUD

FLASHING BY BUILDER

PACKING BY BUILDER

PACKING BY BUILDER

FLASHING BY BUILDER

ARCHITRAVE

36

138.0

65

.0

138.0

138.0

65

.0