RAILROAD COMMISSION OF TEXAS Completion Guidance Oil and Gas Regulatory Conference September 25,...
-
Upload
mark-griffin -
Category
Documents
-
view
216 -
download
1
Transcript of RAILROAD COMMISSION OF TEXAS Completion Guidance Oil and Gas Regulatory Conference September 25,...
RAILROAD COMMISSION OF TEXAS
Completion Guidance
Oil and Gas Regulatory ConferenceSeptember 25, 2013Speaker - Jim Moore
2
Terms & Definitions
• UIC : Underground Injection Control • UIC Number : 9 digit number assigned to Well• W-2 : Oil/Injection/Disposal Well Completion • G-1 : Gas/Injection/Disposal Well Completion• H-1 Number : aka F- number, Project number, Water
Injection Permit No., 5 digits• W-14 Number : aka Permit number, Salt
Water Disposal Permit No., 5 digits• API Number : 10-14 digit number assigned to Well• Well Number : D or L D D D L L , 6 digits
3
Terms & Definitions (cont.)
• RRC District Number• RRC Oil Lease No. : 5 digit Number • RRC Gas ID : 6 digit Number• W-1 : Permit to Drill, Recomplete or Re-Enter• Plat : Lease Map, Survey Location• RRC–designated Field Name, Field Number• H-1 Field Name : correlative to injection/disposal
Formation (deepest if more than one Formation)• W-14 Field Name : correlative to disposal
Formation, or to disposal fluids source Formation
4
Terms & Definitions (cont.)
• W-15 : Cementing Report • W-12 : Inclination Report• P-4 : Certificate of Compliance and
Transportation Authority• L-1 : Electric Log Status Report • GAU : Groundwater Advisory Unit, formerly
TCEQ, formerly TNRCC, formerly T.D.W.R.
5
LOG IN TO ONLINE SYSTEM
Operator needs both Security Administrator Designation (SAD) &User ID.
Each User ID has certain filing rights per program.
6
FORM - SECURITY ADMINISTRATOR DESIGNATION (SAD)
7
RRC HOMEPAGE
Select Online Filings
8
ONLINE FILINGS
Select Security Administration For Filing Operations (Oil and Gas Operators)
9
DATA SUBMISSION REQUIREMENTS
Select user account creation/ maintenance for a multi-step tutorial
10
ONLINE APPLICATIONS
Select Completions
Select Account Administration to setup User ID’s
11
FILING OPTIONS / MESSAGES
File a New Completion or Update Existing Completion Packet
Check Messages, Find Unresolved Messages for All Packets with this User ID
Completions Menu
12
WELL COMPLETION PACKAGE
Click Search
EnterDrilling Permit No. orAPI No.
13
WELLS FOUND
Multiple Field Names Allowed on Drilling Permit
Field Name Must Match Injection/Disposal Permit
Select NewPacket
14
FORM W-1 DRILLING PERMIT
15
W-1 APPLICATION FOR PERMIT TO DRILL, RECOMPLETE OR RE-ENTER
REQUIRED FOR :New WellDeepeningRe-enterPlug Back / Re-Completion / Workover FieldRefer to State Wide Rule (SWR) 5Online filing available(512) 463-6751
16
PACKET DATA – NEW
Purpose of FilingType of CompletionWell TypeWellbore ProfilePacket Type
17
PACKET DATA – NEW (cont.)
18
PACKET DATA – NEW (cont.)
19
PACKET DATA – NEW (cont.)
(ForWaterSupplyWell)
20
PACKET DATA – NEW (cont.)Wellbore Profile is Auto-Populated based on W-1, Drilling Permit
21
PACKET DATA – NEW (cont.)
22
PACKET DATA – CREATE
Click Create Packet tab
Tracking Number gets assigned
Purpose of FilingType of CompletionWell TypeVertical ProfilePacket Type
Done
23
PACKET DATA OIL / W-2
Fill in Well Data
60-70% View or Scroll
Search for Current Field & Reservoir
Table for Workover, Reclass or Well Number Change
Enter H-1 or W-14 Permit No. & Date
Save
Next W-2
24
W-2 PAGE 1
Page 1: Potential Test Data not required when filing for Active or Shut-In UIC (Well Type)
Save, then Next Page #
25
W-2 PAGE 2
Save
Fill In Well Data
System responds with red text warnings if critical data is missing on this page.
26
W-2 PAGE 3
Form W-12“Waterboard Letter” Date or SWR-13 Exception Date Form W-15
27
W-2 PAGE 4
Casing Record
Liner Record
Tubing Record
28
W-2 PAGE 4 (Casing Record)
Multi-Stage Tool Depth Weight B #/FT are only fields that can be left blank.
If using multi-stage (DV) tool, use separate line for each cement stage.
29
W-2 PAGE 4 (Liner Record)
Liner record if applicable, attach W-15 for new liner
30
W-2 PAGE 4 (Tubing Record)
Tubing Size & Depth Set (Feet) Packer Set Depth
31
W-2 PAGE 5
Actual Perfs, not Permitted IntervalCheck Yes only for Unperf’d Shut-In
List all Work Chronologically, attach W-15 for new BP, Cement Squeeze, Squeeze Perfs, etc.
List 3 Formation Tops
Please add Remarks
32
W-2 PAGE 6
Certify (or Re-certify due to RRC analyst Messages)
Electronic Signature
Red text warnings if critical data is missing on W-2 pages.
Next Complete Additional Forms
33
ADD ADDITIONAL FORMS
Online Forms
Attachment FormsBy Type
Select W-15 Cementing Report
Complete Additional Forms
Determine All Required Forms
34
ATTACHMENTS W-15
Current Attachments
Browse to your file location such as Desktop (.pdf, .tif) of W-15 filled out
Upload
35
FORM W-15 CEMENTING REPORT
36
W-15 CEMENTING REPORT
REQUIRED FOR :New WellRemedial Cementing, Casing RepairsCement / Block Squeeze (CS), Squeeze Perfs,
Bridge Plug (BP), Plug BackInjection/Disposal Permit Special Conditions,
H-1/H-1A, W-14
37
ATTACHMENTS W-12
Current Attachments
Pick 1 of 2 ways to initiate the next Upload Attachment step, click here or go back to Complete Additional Forms
38
ATTACHMENTS W-12 (cont.)
Select W-12
Pull-Down or Pull-Up Menu for Attachment Type
39
ATTACHMENTS W-12 (cont.)
Current Attachments
Browse to your file location such as Desktop (.pdf, .tif) of W-12 filled out
Upload
40
FORM W-12 INCLINATION REPORT
41
ATTACHMENTS W-12 (cont.)
Current Attachments
Select Complete Additional Forms to Add W-12 Inclination Report Online Form
42
ADD ADDITIONAL FORMS (cont.)
Online Forms
Attachment FormsBy Type
Select W-12 Inclination Report
Complete Additional Forms
43
W-12 ONLINE FORM
Well Information
Shot Point InformationCertify (or Re-certify due to RRC analyst Messages)
Electronic Signature
Complete Additional Forms
44
W-12 INCLINATION REPORT
REQUIRED FOR : Total Depth > 2000 feetNew WellRe-Entry requires new survey if one was not
already filed when the well was originally drilled
Deepening Refer to SWR 11
45
Directional Surveys, Gyro, MWD
REQUIRED FOR :New Drill if the Wellbore Profile is Directional or
Horizontal. Applicable to some Re-Entry, or Deepening.New Drill if the Wellbore Profile is Vertical and the W-
12 violates SWR 11(c)(1)(A). Applicable to some Re-Entry, or Deepening.
Directional Surveys can only be filed/uploaded by the responsible service company.
Follow RRC Engineering Unit & Support Upload Procedures (512) 463-1126.
46
ADD ADDITIONAL FORMS (cont.)
Online Forms
Select P-4 Certificate of Compliance and Transportation Authority
Complete Additional Forms
47
P-4 ONLINE FORM
Service Well, YesCertify (or Re-certify due to RRC analyst Messages)
Gatherers and/or Purchasers info blank for injection/disposal well.*
RRC Gas ID or Oil Lease No. is blank/zero
48
P-4 CERTIFICATE OF COMPLIANCE
APPLICABLE TO :Initial Potential, Reclass, Well Record Only
when a new Oil Lease / Gas ID number needs to be assigned
Some Workover/Re-Completions from one RRC-designated Field to another RRC-designated Field
Zero lease injection/disposal permits
49
ADD ADDITIONAL FORMS (cont.)
Online Forms
Select L-1 Electric Log Status Report
Complete Additional Forms
50
L-1 ONLINE FORM CONFIDENTIAL
Certify (or Re-certify due to RRC analyst Messages)
Electronic Signature
For Basic Electric Log Run with Confidentiality
Complete Additional Forms to Attach L-1 Electric Log Header
51
ADD ADDITIONAL FORMS (cont.)
Online Forms
Attachment FormsBy Type
Select L-1 Electric Log Header
Complete Additional Forms
52
ATTACHMENTS L-1 LOG HEADER
Current Attachments
Browse to your file location such as Desktop (.pdf, .tif) of Log Header
Upload
53
ATTACHMENTS L-1 LOG HEADER (cont.)
Current Attachments
54
SAMPLE ELECTRIC LOG HEADERS
55
L-1 ONLINE FORM - LOG RUN
Certify (or Re-certify due to RRC analyst Messages)
Electronic Signature
For Basic Electric Log Run, Log Attached
56
MAIL LOG TO RRC AUSTIN
Mail Continuous Log to RRC Austin• 1701 N. Congress • Austin, Texas 78701
Or• P.O. Box 12967• Austin, Texas 78711-2967
Write Tracking Number on Log
57
ADD ADDITIONAL FORMS (cont.)
Online Forms
Attachment FormsBy Type
Select Groundwater Advisory Unit Letter
Complete Additional Forms
58
ATTACHMENTS GAU LETTER
Current Attachments
Browse to your file location such as Desktop (.pdf, .tif) of GAU Letter
Upload
59
ATTACHMENTS GAU LETTER
Current Attachments
60
SAMPLE GAU LETTER
61
SUBMIT PACKET
Certified Online Forms: W-2, W-12, P-4 Data, L-1 Status
Current AttachmentsW-15, W-12, L-1 Log Header, GAU Letter
SubmitService Well Yes
Submit
SUBMIT PACKET (“2nd” screen)
62
Submit
NoNo
Attempt to SubmitWith Forms LackingAnswered No
Submit
63
SUBMIT PACKET FORMS LACKING
Submit with required forms missing or uncertified?: Yes
And / Or Submit with required attachments missing?:
YesSubmit Packet with 1 or both questions marked Yes from the Submit Packet “2nd” screen.If RRC analysts give Final Approval to the Completion Packet with Forms Lacking, then the Operator will need to provide the missing forms or attachments as soon as possible.
64
SUBMIT PACKET (cont.)
… submitted successfully message
65
MESSAGES
Messages Tab
66
PROBLEM RESOLUTION
• Check for RRC analysts Messages on Packet.• Provide additional data, forms, attachments. • Re-certify all Online Forms that are released.• Re-submit Packet if released.• Problem resolution– W-1 Amendment– H-1/H-1A or W-14 Amendment– UIC “pre-severance” or severance letter– Refer to SWR 16
67
QUESTIONS
68
INJECTION-STORAGE PERMITS & SUPPORT
Section (512) 463-6792David Hill, Manager (512) [email protected] Moore (512) [email protected] (Bob) Freymuller (512) [email protected] Mabruk (512) [email protected] Davis (512) [email protected] Burns (512) [email protected] Ashley Johnston (512) [email protected]
69
RRC HOMEPAGESelect Online Research (Queries), to Search for Scanned Images of Filed Well Data, GAU Letters, H-1/H-1A & W-14 Applications
70
ONLINE RESEARCH QUERIES
Select Oil & Gas Imaged Records Query Menu, Launch Application
71
OIL AND GAS IMAGED RECORDS QUERY MENU – LINKS TO NEUBUS WEBPAGE
Oil & Gas Well Records;Search by API No.
GroundwaterProtection Letters;Search by API No., or District/Lease No.
W-14, H-1/H-1A; Search by Permit or Project No.