RACYJISTERAUNDETREG EDRS P R ELECTRICAL ......IRUNWAY 11-29 #83 JAWOS #62 KAWOS CONTROL #122 LRUNWAY...
Transcript of RACYJISTERAUNDETREG EDRS P R ELECTRICAL ......IRUNWAY 11-29 #83 JAWOS #62 KAWOS CONTROL #122 LRUNWAY...
N
SCALE: 1"=30'
30 0
FEET
30 60
SHEET INDEX
54
53
INDIVIDUAL
CONDUITS
TRENCH, CONDUIT,
OR DUCT BANK
SYMBOL
SIGN/LIGHT COLOR LEGEND
DUCT BANK LABEL LEGEND
TRENCH, CONDUIT &
5-3 / 2A / 4B / 3D-#6g, 2C-#4g
GND WIRE SIZE
CIRCUIT CODE
NUMBER OF CABLES
NUMBER OF
CONDUITS
BACKGROUND
OR LENS COLOR
CHARACTER
OR LENS COLOR
W/R
B - BLACK
C - CLEAR
G - GREEN
O - OBSCURED
R - RED
W - WHITE
Y - YELLOW
UNLIGHTED TAXIWAY ENDING MARKER
RELOCATED L-861T STAKE MOUNTED MITL
COUNTERPOISE GROUND ROD
CONDUIT & CABLE
PLOWED COUNTERPOISE
DUCT BANK - BURIED UNDER PAVEMENT
(CONCRETE ENCASED)
DUCT BANK - BORED UNDER PAVEMENT
SYMBOL DESCRIPTION
ELECTRICAL SYMBOL LEGEND
EXISTING REMOVE NEW RELOCATE ADJUST
SYMBOL STATUS
X
R A
NOTES
1. ALL STATIONS AND OFFSETS GIVEN WITH RESPECT TO BASELINE
"RW" (RUNWAY 5-23 CENTERLINE) UNLESS OTHERWISE NOTED.
2. REFER TO "DEMOLITION PLAN" SHEETS FOR REMOVAL OF
EXISTING ELECTRICAL FIXTURES.
3. TIE INTO EXISTING CIRCUIT AS ORDERED BY THE ENGINEER (NO
SEPARATE PAY ITEM).
4. LOCATION, TYPE, AND NUMBER OF FIXTURES SHOWN IS
APPROXIMATE AND SHALL BE CONFIRMED IN THE FIELD BY THE
CONTRACTOR.
5. CIRCUIT ROUTING SHOWN IS APPROXIMATE AND SHALL BE
CONFIRMED IN THE FIELD BY THE CONTRACTOR.
6. TERMINATE COUNTERPOISE AT GROUND ROD. BOND TO
EXISTING COUNTERPOISE, WHERE APPLICABLE.
R G
R G
R G
R G
R G
R G
R G
R G
E
E
H
CM
142+00 143+00 144+00 145+00 146+00 147+00 148+00 149+00 150+00
RUNWAY 5-23 (BL "RW")
142+50 144+00 145+50 147+00 148+50 150+00
142+50 144+00 145+50 147+00 148+50 150+00
300' LT
150' RT
150' LT
300' LT
150' RT
150' LT
PROTECT EXISTING
RUNWAY LIGHTING
CIRCUIT
STA 147+23.0±, 225.0'± LT
SEE "TAXIWAY ENDING
MARKER SIGN DETAIL".
CIRCUIT SCHEDULE
SYM CIRCUIT & CABLE DESCRIPTION SIZE NOTES
A
TAXIWAY A (SOUTH)
#8 1
B
TAXIWAY A (NORTH)
#8 1
C RUNWAY 5-23 #8 1
D
RUNWAY 5-23 (TEMPORARY)
#8 1
E RUNWAY 23 PAPI #8 1
F RUNWAY 5 REIL #12 2
G RUNWAY 23 REIL #12 2
H AIRFIELD LIGHTING CONTROL #12 4
I RUNWAY 11-29 #8 3
J AWOS #6 2
K AWOS CONTROL #12 2
L RUNWAY 23 WINDCONE #12 2
(1) 5,000 Volt Type C Cable
(2) 600 Volt Type THWN-2 Cable
(3) 600 Volt U.S.E. Cable
(4) 10 Pair #12 AWG THWN
TRENCH, CONDUIT, & DUCT BANK SCHEDULE
SYM DESCRIPTION
1 TRENCH - LIGHTNING PROTECTION
2 TRENCH - DIRECT BURIED CABLE
3
CONDUIT - WITHOUT COUNTERPOISE (2" PVC)
4
CONDUIT - WITH COUNTERPOISE (2" PVC)
5
CONDUIT - BORED OR TRENCHED UNDER PAVEMENT
(2" HDPE OR PVC) +
6
CONDUIT - INSTALLED UNDER NEW PAVEMENT (4" PVC) **
7
CONDUIT - TRENCHED THROUGH EX. PAVEMENT (2" PVC) **
8 CONDUIT OR DUCT BANK - EXISTING
9
DUCT BANK - INSTALLED UNDER NEW PAVEMENT (2" PVC) +
10
CONDUIT (4" PVC)
11
CONDUIT (6" PVC)
12
DUCT BANK - TRENCHED THROUGH EX. PAVEMENT (4" PVC) +
13
DUCT BANK - TRENCHED THROUGH EX. PAVEMENT (6" PVC)
14
DUCT BANK - TRENCHED THROUGH EX. PAVEMENT (2" PVC) +
15
CONDUIT - BORED UNDER PAVEMENT (2" HDPE) +
* EMPTY
+ Aircraft Rated Pavement
** Non-Aircraft Rated Pavement
20'
NO. REVISIONS BY APP. DATE
CONSULTANTS, INC.
XR
EF
S: 20009-plan-ex.dw
g; 20009-skey.dw
g; 20009-geom
-pro.dw
g IM
AG
ES
:
DR
AW
IN
G: 20009-E
LE
.dw
g LA
YO
UT
: L2
DELTA AIRPORTJOB NO.
SHEET
DATE:SCALE:
DESIGNED BY:
DRAWN BY:
AIP NO.
OF
w w w . d e l t a a i r p o r t . c o m
3544 North Progress Avenue, Suite 200Harrisburg, Pennsylvania 17110
phone: (717) 652-8700 fax: (717) 652-8371
REHABILITATE RW 5-23 BID PACKAGE 5
ELECTRICAL LAYOUT
GREATER CUMBERLAND REGIONAL AIRPORT
3-24-0013-027-2020 20009
PJW
JDB / SKN
MAY 2021
54