STANDARDS, 1999 NATIONAL ELECTRICAL CODE ®

RA

CO

FLO

OR

BO

XE

S

General ApplicationsRACO floor boxes are ideally suitedfor heavy floor traffic applications,such as shopping malls, retail stores,banks and schools. Floor boxes areinstalled in poured concrete floorsand are fed with conduit. RACO’scomplete line includes both singleservice and three-service (power andvoice/data) floor boxes, which areavailable in cast iron, stamped steeland PVC plastic. Floor box coversand carpet flanges are offered inbrushed brass and textured thermoplastic in two designer colors,ivory and gray. RACO floor boxes:• Are used in branch circuit wiring

• Accommodate wiring devices suchas receptacles for voice/data

• Provide excellent protection forwiring system or devices

• Must be closed with a cover

• Permit access to conductors for maintenance

Non-Adjustable Style Floor Box FeaturesThis type of box has no means foradjustment. It is usually installed inwooden floors or used for retrofit in concrete.

RACO quality non-adjustable floorboxes feature:

• Rugged cast iron for strength and ground continuity

• Factory-installed ground wire

• Simple one-piece floor box designoffers flexibility for power outlet or voice/data outlets

• Conveniently positioned conduitentries are tapped and plugged

Fully-Adjustable Floor Box FeaturesThis type of box has leveling screws for height and leveling adjustments to be made before the concrete is poured, and final leveling adjustments after the concrete is poured. The maximumleveling adjustment is a 7° tilt.

Fully-Adjustable Floor Boxes feature:

• Concrete-tight floor boxes for usein power or voice/data

• Cast iron boxes classified aswater-tight and concrete-tight, typically used below grade where excessive moisture is present

• Choice of materials — stampedsteel or cast iron

• Cast iron floor box including factory-installed ground wire, and multiple gang boxes with one ground wire per gang

• Multiple gang boxes provided with low voltage partitions

• Ample wiring space for any combination of power outlet or voice/data outlets

Standard Materials• Nonmetallic floor box is made

of heavy-duty PVC (Polyvinyl chloride) compound. Base material is recycled

• Steel floor boxes are made of .0625-inch-thick steel

• Cast iron floor boxes are madefrom cast iron having a high tensile strength

• Solid brass covers and carpetflanges

• Nonmetallic floor box covers and carpet flanges are made ofhigh-strength thermoplastic (ABS).

Standard Finishes• Natural gray finish on nonmetallic

floor box

• Nonmetallic floor box covers andcarpet flanges are available in grayand ivory

• Steel boxes have a zinc coating

• Cast iron floor boxes have a graypowder coat paint finish

• Solid brass covers and carpetflanges have a brushed finish

CompliancesFloor boxes are subject to the samecode requirements and minimumconductor fill requirements as otherboxes. RACO floor boxes carry thefollowing compliances:

• UL Standard 514-A, file E4872

• Boxes are listed for their ElectricalApplications (Electrical Codes), UL Green Book

• U.S. Federal Specification andStandards W-C-583B

• Federal Manufacturer’s number 28488

Reference Data• Minimum wiring capacity

calculation can be found on pages A8 of this catalog.

Floor Box InstallationInstalling a fully-adjustable floor boxin a poured concrete floor: RACOprovides with all box assemblies orflanges a metallic concrete cover.The concrete cover permits pouringconcrete to the top of the box. Thecover is then easily removed after the pour. To install the box:

• Locate box and install conduit in accordance with local codes

• Secure box to reinforcing bar (mesh)

• Make pre-pour height and leveling adjustments

• Grease inside of cement cover and install on box

• Grease outside of cement cover

• Apply bead of grease on exposedportion of adjusting collar

• Tape cement cover to box

• Pour concrete

• After the concrete has set, removethe concrete cover

• Pull wires and install wiring device

• Make final pour adjustments, andgrout around the box if required

• Install cover plates and/or accessories

Page 3: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

RA

CO

FLO

OR

BO

XE

S

SUMMARY OF THE MOST OFTEN REQUESTED ARTICLES OF THE 1999 NATIONAL ELECTRICAL CODE

210-52 (a) Dwelling Unit Receptacle Outlets — GeneralProvisions. In every kitchen, family room, dining room,living room, parlor, library, den, sun room, bedroom,recreation room, or similar room or area of dwellingunits, receptacle outlets shall be installed so that nopoint along the floor line in any wall space is more than6 feet, measured horizontally, from an outlet in thatspace, including any wall space 2 feet or more in widthand the wall space occupied by fixed panels in exteriorwalls, but excluding sliding panels in exterior walls. Thespace afforded by fixed room dividers, such as free-standing bar-type counters or railings, shall be includedin the 6-foot measurement.

250-146 Connecting Receptacle Grounding Terminal to Box. An equipment bonding jumper shall be used to connect the grounding terminal of a grounding-typereceptacle to a grounded box. Exception (c): Floorboxes designed for and listed as providing satisfactoryground continuity between the box and the device.

370-27 (b) Outlet Boxes —Floor Boxes. Boxes listedspecifically for this application shall be used for recep-tacles located in the floor. Exception: Boxes located inelevated floors of show windows and similar locationswhere the authority having jurisdiction judges them to be free from physical damage, moisture, and dirt.

800-52 (c) Installation of Communications Wires,Cables, and Equipment — Electric Light or PowerCircuits. Communications conductors shall not beplaced in any raceway, compartment, outlet box, junction box, or similar fitting with conductors of electric light or power circuits or Class 1 circuits.

HOW RACO PRODUCTS HELP COMPLETE THE INSTALLATION

Every 6 feet along the wall surface there should be a receptacleoutlet regardless of the room within the dwelling. The purpose ofthis Article is to eliminate extension cords that are used within thedwelling. Electrically overloaded extension cords are often asource of fires. Installation of a RACO floor box may help alleviatethe need for extension cords by locating receptacles where nowall outlets are installed.

Receptacle outlets in floors can be counted as part of the requirednumber of receptacles if they are within 18 inches of the wall.

All RACO floor boxes are designed and listed for having groundcontinuity without an equipment bonding jumper. RACO does pro-vide on all of its cast floor boxes a factory-installed ground wire.

Only boxes that are UL Listed for the application may be fastened into the floor.

This Article applies when power and voice/data are brought to one enclosure. A means of dividing the wiring is required. Voltagedividers are available for the following floor box types: PVC floorbox and rectangular fully-adjustable.

RACO FLOOR BOXES

Page 4: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

6249Brass Dup lexCover w/L i f t

L ids

6224 or 6223w/o cover

Cas t I ron F loo r Box

6284Brass Dup lex

Cover w/P lugs

6226 6226 6209 or 6225

6208 or 6206 or 6205

6285, 6287Brass Cover

w/Combina t ionP lugs

6255, 6257*Stamped S tee l

6261, 6263*Cas t I ron

6250Brass Dup lex Cover

w/L i f t L ids

6288Brass Dup lex Cover

w/P lugs

6289, 6291Brass Cover

w/Combina t ion P lugs

6230, 6235Brass Carpe t F lange

6233Clear

Po l ycarbona teCarpe t F lange

6292, 6295Clear Po l ycarbona te

or So l id B rass Carpe t F lange

6293, 6296Clear Po l ycarbona te

or So l id B rass Carpe t F lange

6294, 6297Clear Po l ycarbona te o r

So l id B rassCarpe t F lange

6256, 6258*Stamped S tee l

S ing le-Gang

6262, 6264*Cas t I ron

S ing le-Gang

6269*Cas t I ron Two-Gang

6275*Cas t I ron

Three-Gang

QUICK SELECTION GUIDEA78

NON-ADJUSTABLE FLOOR BOX SYSTEM

FULLY-ADJUSTABLE FLOOR BOX SYSTEM

R O U N D F L O O R B O X R E C TA N G U L A R F L O O R B O X

6249Brass Dup lexCover w/L i f t

L ids

6284Brass Dup lex

Cover w/P lugs

6226

(1 Cover Needed ) (2 Covers Needed ) (3 Covers Needed )

6285, 6287Brass Cover

w/Combina t ionP lugs

6209 or 6225

6206 or 6205

6209 or 6225

6206 or 6205

* Inc luded b rass t i l e r i ng mus t be removed and d iscarded be fo re ins ta l l a t i on o f b rass ca rpe t f l anges . Po l ycarbona te f l anges a re ins ta l l ed be tween box and inc luded b rass r ing

6230, 6235Brass Carpe t F lange

RA

CO

FLO

OR

BO

XE

S

Page 5: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

QUICK SELECTION GUIDEA79

6249Brass Dup lex

Cover w/L i f t L ids

6284Brass Dup lex

Cover w/P lugs

6285, 6287Brass Cover

w/Combina t ionP lugs

5558, 5568Nonmeta l l i c

Dup lex Coverw/L i f t L ids

Nonmeta l l i c o r B rass

Dup lex Coverw/L i f t L ids

6298Brass Ti l e /F lush

F lange

6235Brass

Carpe t F lange

6233Clear

Po l ycarbona teCarpe t F lange

5554, 5555Nonmeta l l i c

Carpe t F lange

Nonmeta l l i c o r B rassCarpe t F lange

5544Adapte r

Adap te r

5534(Op t iona l ) *

Low Vo l tage D iv ide r

5574(Op t iona l ) *“Y” Adapte r

PVC FLOOR BOX SYSTEM

6226 5561, 5599,6279

6209 or 6225

6206 or 6205

* Nonmeta l l i c Box – Mu l t i -Serv ice Opt ion : A vo l tage separa t i on un i t s a l l ows the nonmeta l l i c box to be used fo r te lephone/data se r v ice as we l l as power. As shown, the un i t has has two p ieces . The lower por t i on has open ings on oppos i te s ides fo r power w i res and ramps on the o ther two s ides fo r te lephone/da ta w i res . Power w i res run ins ide tube and at tach to dup lex recep tac le . Te lephone/da ta w i res run ou ts ide o f tube and pass th rough grommet (s ) i n the cover

Be fo re ins ta l l i ng l ower par t o f vo l tage separa t i on un i t , cu t o f f the same amount f rom the tube as you cu t o f f the box . Comple te the ins ta l l a t i on o f the ca rpe t f l ange , dup lex recep tac le and cover

5511PVC F loo r Box

RA

CO

FLO

OR

BO

XE

S

Page 6: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

5511 5534

5574

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

19.5 cub ic inch capac i t y pe r inch o f he igh t5511 (2 ) 1" and (2 ) 3 /4" open ings . Temporar y 1

cover and (4 ) reducer /c losure p lugs inc luded .

5534 Vo l tage separa t i on un i t , op t iona l 10

5574 3/4" Y adap te r, PVC 10 —

5544 Adapte r r ing fo r a l l nonmeta l l i c 10 —and brass f l anges

R O U N D F L O O R B O X A N D A C C E S S O R I E S – N O N M E TA L L I C

FLOOR BOXESFOR CONCRETE POUR – NONMETALLIC

A80

ORDERING INFORMATION - DIMENSIONS

Applications• Used in branch circuit wiring• Accommodate wiring devices

for various receptacles• Permit access to conductors

for maintenanceGeneral Features • RACO® nonmetallic floor box has

been engineered from the insideout with features that reduceinstallation time and offer increasedcapabilities from one box in power,voice, and data

• Hubbell nonmetallic floor boxes are economical to install and easyto level off

• A wide choice of cover materialsand finishes are available

Low Voltage Divider Features• Installs inside 5511 floor box for

multi-service applications. Useseparate conduit runs for powerand voice/data cables

• Accepts Hubbell standard duplex receptacles or 15A Twist Lok® duplex receptacles(HBL 4700 series)

• Power capacity — 19.60 cubicinches plus 2.40 cubic inches perinch of tube

Adapter Ring Features• Required for each 5511 floor box

(accepts plastic and metal covers)

• Mechanically fasten adapter to5511 floor box with includedretaining clips and screws. Clipsslide into slots in box wall

PVC Floor Box Features• High-strength rigid non-corrosive

PVC construction

• Large capacity box: 100 cubicinches of volume (before cut)

• Molded T-slots permit the adapterring to be secured to the box nomatter where the box has been cut

• One-piece box with pre-moldedconduit hubs

• RACO® Y-Adapter permits two parallel feeds of 3/4" conduit, or feed in/out of the same side

Compliance•

®

NONMETALLIC FLOOR BOX

5544

RA

CO

FLO

OR

BO

XE

S

Page 7: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

FLOOR BOXESNONMETALLIC

CATALOG CARPET FLANGE STD. UPCNUMBER

DESCRIPT IONO.S . D IAMETER PKG . BAR CODE

5561Adapte r, nonmeta l l i c i vo r y ca rpe t f l ange ,I vo r y dup lex cover

6-1/4" 10

5599Adapte r, nonmeta l l i c g ray ca rpe t f l ange ,Gray dup lex cover

6-1/4" 10

6279Adapte r, b rass ca rpe t f l angeBrass dup lex cover

6-1/4" 10

A81

ORDERING INFORMATION - DIMENSIONS

F L O O R B O X C O V E R A S S E M B LY K I T N O N M E TA L L I C A N D B R A S S

REPLACEMENT COVERS

5558, 5568 5554, 5555

REPLACEMENT CARPET FLANGES

CATALOG CARPET FLANGE STD. UPCNUMBER

DESCRIPT IONO.S . D IAMETER PKG . BAR CODE

5558 I vo r y nonmeta l l i c dup lex cover w i th l i f t l i ds — 10 —

5568 Gray nonmeta l l i c dup lex cover w i th l i f t l i ds — 10 —

5554 I vo r y nonmeta l l i c ca rpe t f l ange 6-1/4" 10 —

5555 Gray nonmeta l l i c ca rpe t f l ange 6-1/4" 10 —

R E P L A C E M E N T C O V E R S A N D C A R P E T F L A N G E S – N O N M E TA L L I C

KITS 5561, 5599 AND 6279 INCLUDE

THESE PIECES

Application• Floor box assemblies provide

a quick, simple method of completing floor box installation on carpeted floor

Product Features • Floor box assembly kits are

designed to be used with RACO®

round nonmetallic floor box, catalog number 5511

• Kits include adapter ring, nonmetallic or brass carpet flange,and nonmetallic or brass cover

• Nonmetallic carpet flanges andcovers are available in gray or ivory finish

• Covers are outfitted with duplex flaps that automaticallyclose when not in use, preventingbreakage and eliminating a potential trip hazard

• Cover design keeps debris outwhen receptacles are not in use

• Hubbell RACO® carpet flanges andcovers install quickly and easilywith provide screws

• 3-service floor box cover withduplex flap, two 1/2" diameter low-voltage knockouts. Each low-voltage knockout can accommodate up to (1) 25 pairtelephone cable or (1) 50 wire data communications cable. Note: Brass cover is not 3-service

Compliance•

®

RA

CO

FLO

OR

BO

XE

S

Page 8: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

A82

ORDERING INFORMATION - DIMENSIONS

FLOOR BOXES ROUND COVERS AND FLANGES

Application• Floor box flanges and covers are

used to complete floor box installa-tions on either carpet or tile

Product Features• Brass floor box covers are

designed to be used with roundRACO® carpet and tile flanges and RACO® round full adjustablestamped steel and cast iron floor boxes

• Flanges are designed to beinstalled to RACO® adapter ring,catalog number 5544

• 6230 is not designed to work withRACO® 5511 nonmetallic floor box

• 6230 and 6235 are not designedto be used with RACO® 6220

• Hubbell RACO® carpet flanges, tileflanges and covers install quicklyand easily with provided screws

• Order of installation

1. Install RACO® floor box

2. Install nonmetallic adapter ring (if round 5511 nonmetallic box is used)

3. Install device to box or 5544 adapter

4. Install carpet or tile flange

5. Install cover to carpet ortile flange

Compliances•

•®

6230, 6235 6233

6249 6284 6285, 6287

CATALOG CARPET FLANGE STD. UPCNUMBER

DESCRIPT IONO.S . D IAMETER PKG . BAR CODE

6230 Brass ca rpe t f l ange , mop- t igh t 5-1/4" 10

6233 Clear po l ycarbona te ca rpe t f l ange 5-1/4" 15

6235 Brass ca rpe t f l ange* 6-1/4" 10

C A R P E T F L A N G E S

CATALOG UNIT SHIP UPCNUMBER

DESCRIPTIONCTN. QTY. CTN. QTY. BAR CODE

6249 Brass dup lex cover w i th l i f t l i ds 10 40

6284Brass dup lex cover w i th 2 , 1/2"th readed p lugs

10 40

6285Brass cover w i th 2-1/8" x 1" comb ina t ion p lugs

10 40

6287Brass cover w i th 2-1/8" x 3 /4"combina t ion p lugs

10 40

R O U N D C O V E R S , B R A S S 3 - 7 / 8 " D I A .

* 6235 no t UL L i s ted

6-1/4" REPLACEMENT CARPET FLANGES

6298

CATALOG T ILE FLANGE UNIT STD. UPCNUMBER

DESCRIPT IONO.S . D IAMETER CTN . QTY. PKG . BAR CODE

6298 Brass t i l e / f l ush4-3/16" 15 60

app l i ca t i on f l ange

T I L E F L A N G E

RA

CO

FLO

OR

BO

XE

S

Page 9: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

UPCCATALOG THREADED/HUBS CU. STD.BARNUMBER SIDE BOTTOM IN. PKG.CODE

6224 — 2–1/2" 18.5 4

A83

ORDERING INFORMATION - DIMENSIONS

FLOOR BOXESFOR WOOD FLOORS

6224 6223

NON-ADJUSTABLE FLOOR BOX

D U P L E X R E C E P TA C L E A S S E M B LY

UPCCATALOG THREADED/HUBS CU. STD.BARNUMBER SIDE BOTTOM IN. PKG.CODE

6223 — 2–1/2" 18.5 4

F L O O R B O X

SIZE A B C D

6223 4.19" 3.39" 0.59" 3.75"

6224 4.19" 3.39" 0.59" 3.75"

6220 3.44" 2.82" .22" 2.63"

D I M E N S I O N S – C A S T I R O N F L O O R B O X

SIZE A B C*

6224 4-1/4" 3-7/16" 5/8"

6220 3-5/8" 2-7/8" 7/16"

D I M E N S I O N S – W O O D F L O O R C U T O U T

Applications• RACO® wood floor boxes

provide flush service for power or voice/data

• Non-adjustable floor boxes may be used in wood or concrete floorsand are suitable for carpet, tile orwood floor applications*

Product Features• Boxes are non-adjustable

• Cast iron, water-tight

• Gray powder coat paint inside and out for additional corrosionresistance

• 1/2" and 3/4" threaded conduit openings are standard; all bottomopenings are accessible

• If floor covering is used, discardincluded brass flush ring andreplace with RACO® 6230 or 6235 brass carpet flange

• RACO® 6220 includes box, 2-1/8" brass flush plug cover,brass tile flange, and 15A, 125Vsingle receptacle (H.W.D part number HBL5258)

• RACO® 6224 includes box, 6249brass duplex cover with lift lids,and brass tile flange. Receptacle is not included

• RACO® 6223 – for use with anyRACO® 3-7/8" diameter brasscover (6249, 6284, 6285, 6287)Cover must be ordered separately,brass tile flange included

Compliance•

®

6220

UPCCATALOG THREADED/HUBS CU. STD.BARNUMBER SIDE BOTTOM IN. PKG.CODE

6220 2–3/4"1–1/2"

10.3 41–3/4"

S I N G L E R E C E P TA C L E A S S E M B LY

* I f f l oo r cover ing i s used , va r y coun te r bo re dep th accord ing ly. Add i t i ona l b rac ing may be requ i red

*CUT OUT FOR FLUSH INSTALLATION

RA

CO

FLO

OR

BO

XE

S

Page 10: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

A84

ORDERING INFORMATION - DIMENSIONS

Applications• RACO® #5236 and 6236 floor box

provide flush service for power

• Non-adjustable floor boxes may be used in wood floors and aresuitable for carpet, tile or woodfloor applications

Product Features• Zinc plated steel yoke for

corrosion resistance

• Back wiring – clamp-type terminalsaccepts up to #10 wire

• Side wiring – large brass bindinghead screw terminals accepts upto #10 wire

• Floor box assembly cover plate is .058 thick brushed brass

• Brass cover size is 2-3/4" wide x 4-1/2" long

• Floor box (6236 only) is 3.5" (88.9) deep

Compliance•

®

5236

FLOOR BOXESFOR WOOD FLOORS

6236

UPCCATALOG KNOCKOUTS/HUBS CU. STD.BARNUMBER SIDE BOTTOM IN. PKG.CODE

5236 — — — 6

R E C E P TA C L E - D I S P L AY T Y P E F O R U S E I N D R Y L O C AT I O N S B R A S S P L AT E A N DT H R E A D E D P L U G

KNOCKOUTS UPCCATALOGSIDES ENDS

CU. STD.BARNUMBER

CONDUIT CABLE BOTTOM IN. PKG.CODE

6236 4–1/2" 4 1–1/2" 18.0 4

F L O O R B O X / P L AT E A S S E M B LY / G A S K E T, B R A S S P L AT E A N D T H R E A D E D P L U GF L O O R B O X F O R N O N - M E TA L L I C S H E AT H E D C A B L E O R C O N D U I TR

AC

O F

LO

OR

BO

XE

S

Page 11: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

A85

ORDERING INFORMATION - DIMENSIONS

FLOOR BOXESFOR CONCRETE POUR – ROUND

6255, 6257 6261, 6263

MIN. BEFORE AFTERCATALOG

KNOCKOUTS/HUBSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE BOTTOMPOUR ADJUST. ADJUST.

CODE

2–1/2" 3–1/2" 2–3/4" 2–3/4"62552–1" —

4" 1.25" .38" 54.0 4

2–1-1/4" —

62576–1/2"

3–1/2" 3" 1.25" .38" 37.3 44–3/4"

F U L LY- A D J U S TA B L E F L O O R B O X S TA M P E D S T E E L

MIN. BEFORE AFTERCATALOG

KNOCKOUTS/HUBSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE BOTTOMPOUR ADJUST. ADJUST.

CODE

6261 4–3/4" — 3-3/4" 1 .25" .38" 33.0 4

6263 4–3/4" — 3" 1.25" .38" 30.0 4

F U L LY- A D J U S TA B L E F L O O R B O X C A S T I R O N

SHALLOW DEEP6263 (CAST) 6257 (STEEL) 6261 (CAST) 6255 (STEEL)

MIN. “A” 2.81" 2.91" 3.09" 3.88"

MAX. “A” 3.19" 3.29" 3.47" 4.26"

“B” 1.69" 1.69" 1.94" 2.71"

D I M E N S I O N S

Applications• Round floor boxes provide flush

service for power or voice/data

• Floor boxes may be used for carpet or tile floor applications

Cast Iron Floor BoxesProduct Features• Cast iron, water-tight body,

fully-adjustable

• Painted gray powder coat paint inside and out for additional corrosion resistance

• 3/4" threaded conduit openingsare standard

Stamped Steel Floor BoxesProduct Features • Stamped steel, concrete-tight,

fully-adjustable

• Zinc-coated finish

• 1/2", 3/4", 1" and 1-1/4" knock-outs; all bottom knockouts areaccessible

General Product Features• Brass tile flange provided with box

• RACO® 6230 or 6235 carpet flange must be ordered separately(included brass tile ring must bediscarded before installing carpet flange)

• RACO® 6249, 6284, 6285, or 6287 brass cover must beordered separately

• Interior and exterior leveling screws permit adjustment to meet finished floor

• Disposable concrete cap to prevent the entry of concrete during pour included

Compliances•

•®

RA

CO

FLO

OR

BO

XE

S

Page 12: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

SHALLOW DEEP

6264 (CAST) 6258 (STEEL) 6262 (CAST) 6256 (STEEL)MIN. “A” 2.88" 2.81" 3.19" 3.90"

MAX. “A” 3.26" 3.19" 3.57" 4.28"

“B” 1.81" 1.81" 2.06" 2.83"

MIN. BEFORE AFTERCATALOG

KNOCKOUTSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE* BOTTOMPOUR ADJUST. ADJUST.

CODE

2–1/2" 3–1/2" 2–3/4" 2–3/4"62562–1" —

4" 1.25" .38" 54.0 2

2–1-1/4" —

62586–1/2" 3–1/2"

3" 1 .25" .38" 37.3 44–3/4" 2-3/4"

FLOOR BOXESFOR CONCRETE POUR – RECTANGULAR

A86

ORDERING INFORMATION - DIMENSIONS

6256, 6258 6262, 6264

S I N G L E - G A N G F L O O R B O X – F U L LY- A D J U S TA B L E , S TA M P E D S T E E L

MIN. BEFORE AFTERCATALOG

THREADED/HUBSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE BOTTOMPOUR ADJUST. ADJUST.

CODE

6262 4–3/4" — 3-3/4" 1 .25" .38" 33.0 4

6264 4–3/4" — 3" 1.25" .38" 30.0 4

S I N G L E - G A N G F L O O R B O X – F U L LY- A D J U S TA B L E , C A S T I R O N

D I M E N S I O N S

Applications• RACO® rectangular series floor

boxes are ideally suited for heavyfloor traffic applications, such asmalls, department stores, banksand schools

• Floor boxes are installed in pouredconcrete floors and are fed withconduit

• RACO® floor boxes are used inbranch circuit wiring

Cast Iron Floor Boxes Product Features• Cast iron, water-tight body,

fully-adjustable

• Gray powder coat paint inside and out for additional corrosionresistance

• 3/4" threaded conduit openings are standard

Stamped Steel Floor BoxesProduct Features• Stamped steel, concrete-tight,

fully-adjustable

• Zinc-coated finish

General Product Features• Brass tile flange provided with box

• RACO® 6292 or 6295 carpet flangemust be ordered separately

• RACO® 6250, 6288, 6289, or 6291 brass cover must beordered separately

• Disposable concrete cap to prevent the entry of concrete during pour included

• Interior and exterior leveling screws permit adjustment to meet finished floor

Compliances•

•®

SINGLE-GANG

* 6256 One 1" and one 3/4" knockou ts on oppos i te s idesOne 1-1/4" and one 1/2" knockou ts on oppos i te ends

* 6258 One 1/2" and one 3/4" knockou ts on oppos i te endsTwo 1/2" and one 3/4" knockou ts on oppos i te s ides

RA

CO

FLO

OR

BO

XE

S

Page 13: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

MIN. BEFORE AFTERCATALOG

THREADED/HUBSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE BOTTOMPOUR ADJUST. ADJUST.

CODE

6269 6–3/4" — 3-3/4" 1 .25" .63" 36.50 ea . gang 1 —

A87FLOOR BOXESFOR CONCRETE POUR – RECTANGULAR

6269 6275

T W O - G A N G F L O O R B O X – F U L LY- A D J U S TA B L E , C A S T I R O N

MIN. BEFORE AFTERCATALOG

THREADED/HUBSDEPTH POUR EXT. POUR INT. CU. STD.

UPC

NUMBER OF HT. FINAL IN. PKG.BAR

SIDE BOTTOMPOUR ADJUST. ADJUST.

CODE

6275 8–3/4" — 3-3/4" 1 .25" .63"34.80 mid . gang

1 —36.50 end gangs

T H R E E - G A N G F L O O R B O X – F U L LY- A D J U S TA B L E , C A S T I R O N

THREE-GANG

ORDERING INFORMATION - DIMENSIONS

Applications• RACO® rectangular series floor

boxes are ideally suited for heavyfloor traffic applications, such asmalls, department stores, banksand schools

• Floor boxes are installed in poured concrete floors and are fed with conduit

• RACO® multiple-gang rectangularfloor box series may be used forboth single-service and three-service (power and voice/data)applications

• RACO® floor boxes are used inbranch circuit wiring

Product Features• Cast iron, water-tight body,

fully-adjustable

• Gray powder coat paint inside and out for additional corrosionresistance

• Interior and exterior leveling screws permit adjustment to meetfinished floor

• Removable partitions included tomeet larger capacity requirementson two- and three-gang boxes

• Disposable concrete cap to prevent the entry of concrete during the pour included

• 3/4" threaded conduit openings are standard

• RACO® 6250, 6288, 6289, or 6291 brass cover must beordered separately

Compliances•

•®

TWO-GANG

DEEP

6269 (CAST) 6275 (CAST)MIN. “A” 3.44" 3.44"

MAX. “A” 4.07" 4.07"

“B” 2.10" 2.10"

D I M E N S I O N S

RA

CO

FLO

OR

BO

XE

S

Page 14: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

ORDERING INFORMATION - DIMENSIONS

A88 FLOOR BOXESRECTANGULAR ACCESSORIES

62886250 6289, 6291

CATALOG UNIT SHIP UPCNUMBER

DESCRIPTIONCTN. QTY. CTN. QTY. BAR CODE

6250 Brass dup lex cover w i th l i f t l i ds 10 40

6288 Brass dup lex cover w i th 1-1/2" th readed p lugs 10 40

6289 Brass cover w i th 2-1/8" x 1" comb inat ion p lugs 10 40

6291 Brass cover w i th 2-1/8" x 3 /4" combinat ion p lugs 10 40

R E C TA N G U L A R F L O O R B O X B R A S S C O V E R S

Application• Rectangular floor box brass covers

and flanges are used to completefloor box installations

Product Features• Rectangular brass covers are used

with RACO® single-gang, two-gang, and three-gang rectangularfloor boxes

• Covers are 3" wide x 4-5/32" long

• Cover screw centers are 3-5/32" x 2-1/8"

• Rectangular carpet flanges are available in brass or clear polycarbonate

Compliances•

•®

6292, 6295 6293, 6296

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

6292 1-Gang b rass 20

6295 1-Gang c lea r po lyca rbona te 10

6293 2-Gang b rass 10 —

6296 2-Gang c lea r po lyca rbona te 10 —

6294 3-Gang b rass 10

6297 3-Gang c lea r po lyca rbona te 15 —

R E C TA N G U L A R C L E A R P O LY C A R B O N AT E A N D B R A S S C A R P E T F L A N G E S

6294, 6297

RA

CO

FLO

OR

BO

XE

S

Page 15: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

A89

ORDERING INFORMATION - DIMENSIONS

FLOOR BOXES ACCESSORIES AND REPLACEMENT COVERS

6208, 6209, 6225, 6226 6227 6228 6237 6238

Applications• Brass abandon plugs are sold

separately for replacement in brass covers

• Split nozzle for 2-1/8" threadedcover consists of interlockinghalves that provide a protectivehousing when assembled. Thenozzle may be easily installed without removing an electrical plug from cord. Nozzle is brasscolored plastic

THREAD FITS RACO ® UPCCATALOGDESCRIPTION TYPE BRASS

STD.BARNUMBER

COVERPKG.

CODE

6209 3/4" Crowned, S lo t ted P lug — 6287, 6291 30

6225 1" Crowned, S lo t ted P lug — 6285, 6289 25

6226 1-1/2" F lush S lo t ted P lug F ine 6284, 6288 25

6208 2-1/8" F lush S lo t ted P lug F ine — 30

62062-1/8" F lush Cap R ingfo r 3 /4" P lug

— 6287, 6291 30

2-1/8" F lush Cap R ing 6205f o r 1" P lug

— 6285, 6289 35

A B A N D O N P L U G S – B R A S S

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

6227 Sp l i t ny lon g ray nozz le 5

S P L I T N O Z Z L E F O R 2 - 1 / 8 " T H R E A D E D C O V E R

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

6228 Rectangu la r cover f l ange 15 —

6237Rectangu la r s ing le-gang rep lacement

4 — ad jus tab le co l l a r

6238 Round rep lacement ad jus tab le co l l a r 4 —

R E P L A C E M E N T C O V E R F L A N G E & A D J U S TA B L E C O L L A R S

RA

CO

FLO

OR

BO

XE

S

Page 16: RACO Floor Boxes - electrical training ALLIANCEelectricaltrainingalliance.org/.../l27-raco-floor-boxes.pdf• Pull wires and install wiring device • Make final pour adjustments,

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

6300 Frame hous ing , 3/4" chase n ipp le , w/o p la tes 6

6301 Frame hous ing , 1" chase n ipp le , w/o p la tes 6

Crea te your own pedes ta l to meet spec i f i c se rv i ce requ i rements Order hous ing , face p la tes separa te l y

A90

ORDERING INFORMATION - DIMENSIONS

6300, 6301

L O W - P R O F I L E S E R V I C E P E D E S TA L H O U S I N G - S I N G L E S E R V I C E F O R P O W E R O RV O I C E / D ATA

CATALOG STD. UPCNUMBER

DESCRIPT IONPKG . BAR CODE

6310 Rectangu la r cover f l ange 25

6311Te lephone bush ing w i th 1 .00" ID and (2 ) 3 /8" KO fo r coax ia l

25

6312 S ing le recep tac le p la te w i th 1 .39" open ing 25

6313 Dup lex recep tac le p la te 25

6314 Decora to r s t y le recep tac le p late 25

6315 Aluminum p la te w i th 1 .11" KO 25

FA C E P L AT E S

MAX. NO. PLATE(S) REQUIRED RACO ®

OF RECPT.RECEPTACLE TYPE

QTY. CATALOG NUMBER

1 Dup lex j ack ou t le t 1 6313, 6310

1 Decora to r s t y le o f te lephone ou t le t 1 6314, 6310

2 Decora to r s t y le o f coax ia l ou t le t 2 6314

0 Bushed open ing 1 6311, 6310

V O I C E / D ATA C O M B I N AT I O N S

MAX. NO. PLATE(S) REQUIRED RACO ®

OF RECPT.RECEPTACLE TYPE

QTY. CATALOG NUMBER

2 Dup lex recep tac les 2 6313

1 GF I recep tac le 1 6314, 6310

1 Surge dup lex recep tac le 1 6314, 6310

2 Decora to r recep tac les 2 6314

2 S ing le recep tac les 2 6312

P O W E R C O M B I N AT I O N S

Service Pedestals Applications• RACO® above-the-floor service

pedestals satisfy most servicerequirements

• These are the traditional metallicpedestals, offered as componentparts to satisfy any combination ofpower or voice/data requirements

Product Features• Service pedestal housing die cast

aluminum frame, aluminum housing

• Stainless steel faceplates

Compliance•

®

SERVICE PEDESTAL

Pedestal Capacity Chart • (Power or voice/data devices)

In certain cases, the pedestal will accommodate two receptacles.In other cases, a device may betoo deep, and the maximumcapacity is one receptacle

FLOOR BOXESSERVICE PEDESTALS AND ACCESSORIES

6310 6311

6312

6314 6315

6313

RA

CO

FLO

OR

BO

XE

S