Q Q 3 o O Q o O c O n O Q Q Q o Q O O c O o Q o O Q O n O ... · Created Date: 1/14/2020 2:33:31 PM
R E T E NT I O N P O DS GO O M M E R C I A L ... - Greenscapes · Ed Beaulieu Welcome 2...
Transcript of R E T E NT I O N P O DS GO O M M E R C I A L ... - Greenscapes · Ed Beaulieu Welcome 2...
R E T E N T I O N P O N D SG O L F C O U R S E S
CO
NS
TR
UC
TE
DW
ET
LA
ND
S
C O M M E R C I A L L A N D S C A P ES U
B DI V
I SI O
NE
NT
RA
NC
ES
Ed Beaulieu Welcome
2 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
The Aquascape Ecosystem
Golf course ponds are used
in storm water management,
and more importantly, irrigation
for the surrounding property.
Golf course designers use these
ponds to create visual interest
and add strategic difficulties
to the course layout. Centipede™ Module
Snorkel™ Vault
AquaBlox™ Water Matrix
4 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
The Snorkel™ and Centipede™ Filtration System
Grande BIOFALLS® filter
Snorkel™ Vault and Extension
AquaBlox™ Water Matrix
Full and Half Centipede™ Modules
AquaClearer™ Extreme Wetland/Pond & Lake Treatment
AquaClearer™ Extreme Wetland/Pond & Lake liquid bacteria effectively reduces ammonia, nitrites, and excess nutrients that would otherwise cause poor water quality and clarity.
Centipede™ Module
Snorkel™ Vault
Flexible PVC
RubberCoupling
Wetland Construction Instructional DVD
See a Snorkel™ Vault and Centipede™ Module installed on a large water feature. Discover how to improve retention ponds, golf course ponds, and earthen ponds.
AquaBlox™ Water Matrix
6 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
4 5
1 2 3
4
Project Spotlight
Image 1: The pond bottom is deepened to allow adequate water flow to our pumps.
Image 2 & 3: The liner or underlayment fabric is used in the excavation
as a barrier between the stone and soil. The Centipede™ Modules are covered
with several layers of 4”- 6” stone which will prefilter the incoming water,
providing the pumps with relatively clean water for optimum pumping.
Image 4: The pumps and plumbing that will feed water to the filter are connected.
Image 5: Final excavation of the area between the wet well and the
pond allows the water from the pond to flood the pumps with water.
Finish grading the area and dress with stone as necessary.
8 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
2
1
3
The Pondless® Waterfall Patent Pending
Image 1 & 3: Omaha Zoo Pondless® Waterfall – Two Snorkel™ Vaults and
Centipede™ Modules were used to house two 7.5 HP pumps creating a combined
flow rate of 44,000 GPH. The water cascades down a 120 ft. stream, over
hundreds of tons of moss rock before disappearing into a bed of river gravel.
Image 2: Subdivision and corporate entranceways make
a perfect settings for Pondless® Waterfalls!
Image 4: This residential Pondless® Waterfall provides
carefree serenity to the homeowner.
Image 5: This Pondless® Waterfall in the Children’s Garden at
Epcot® satisfies the curious minds of both children and adults.
EcoSystems® Pondless® Waterfall AlgaeBlast™
EcoSystems® Pondless® Waterfall AlgaeBlast™ attacks
and prevents algae growth in Pondless® Waterfalls
safely and effectively. As regular maintenance, repeat
treatment when algae growth begins to reappear.
Do not use in water fountains and patio ponds
with live plants, snails or other invertebrates.
Prevents green water
Prevents algae growth
10 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
1
2
Compressor Cabinet
Self-weighted aeration tubing
4’ depth or greater
Large Pond Bottom Aeration
Image 1: Self-cleaning aeration
discs require NO maintenance.
Image 2: The compressor
cabinet has a heavy-duty cooling
fan and easy plug in connection to
waterside GFCI electrical service.
Aquascape’s ProAir™ 1 Installation
12 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
Large Project Pumps
100
90
80
70
60
50
40
30
20
10
00 100 200 300 400 500 600 700 800 900 1000
HD (f
t)
US GPM
Tubo Major N
Minette 1
KTZ31.5-60 Tubo Minor N
Tubo Master N
Minette 3
KTZ43.7-60
TsurumiGrindex
Pumps for Low Head Applications (50’ or less in TDH)Manufacturer Discharge Model HP Phase Volts Amps Vertical
ShutoffMax Cap.
GPMWeight Height Width Separate Control
Panel neededInverter Panel
Tsurumi 3” KTZ 31.5-60 2 Three-phase 230 6 48’ 185 64 lbs. 19.59” 9.25” #9002, manual yes
Tsurumi 3” KTZ 31.5-60 2 Three-phase 460 3 48’ 185 64 lbs. 19.59” 9.25” #9000, manual n/a
Tsurumi 4” KTZ43.7-60 5 Three-phase 230 13 61’ 383 123 lbs. 24.60” 11.16” #9003, manual yes
Tsurumi 4” KTZ43.7-60 5 Three-phase 460 6.5 61’ 383 123 lbs. 24.60” 11.16” #9002, manual n/a
Grindex 3” Minette 1 2.5 Single-phase 230 12 60’ 250 55 lbs. 21” 11” included yes
Grindex 3” Minette 3 3.5 Three-phase 230 9 60’ 310 55 lbs. 21” 11” included yes
Grindex 3” Minette 3 3.5 Three-phase 460 4.5 60’ 310 55 lbs. 21” 11” included yes
Grindex 4” Tubo Minor N 5.8 Three-phase 230 14 78’ 525 86 lbs. 23” 11” Tubo Minor 12” Control yes
Grindex 4” Tubo Minor N 5.8 Three-phase 460 6.9 78’ 525 86 lbs. 23” 11” Tubo Minor 12” Control yes
Grindex 4” Tubo Major N 8.5 Three-phase 230 22 85’ 650 99 lbs. 23” 11” Tubo Major 12” Control 230V yes
Grindex 4” Tubo Major N 8.5 Three-phase 460 11 85’ 650 99 lbs. 23” 11” Tubo Major 12” Control 460V yes
Grindex 4” Tubo Master N 13 Three-phase 230 33 100’ 900 123 lbs. 25” 11” Tubo Master 12” Control 230V yes
Grindex 4” Tubo Master N 13 Three-phase 460 16 100’ 900 123 lbs. 25” 11” Tubo Master 12” Control 460V yes
Pumps for High Head Applications (100’ or less in TDH)Manufacturer Discharge Model HP Phase Volts Amps Vertical
ShutoffMax Cap.
GPMWeight Height Width Separate Control
Panel neededInverter Panel
Tsurumi 3” KTZ 33.7-60 5 Three-phase 230 13 102’ 237 121 lbs. 19.59” 11.16” #9003 yes
Tsurumi 3” KTZ 33.7-60 5 Three-phase 460 6.5 102’ 237 121 lbs. 19.59” 11.16” #9002 n/a
Tsurumi 4” KTZ47.5-60 10 Three-phase 230 25 139’ 356 205 lbs. 26” 13” #9005 yes
Tsurumi 4” KTZ47.5-60 10 Three-phase 460 12.5 139’ 356 205 lbs. 26” 13” #9003 n/a
Tsurumi 4” or 6” KTZ67.5-60 10 Three-phase 230 25 102’ 554 205 lbs. 28.66” 14.7” #9005 yes
Tsurumi 4” or 6” KTZ67.5-60 10 Three-phase 460 12.5 102’ 554 205 lbs. 28.66” 14.7” #9003 n/a
Grindex 4” Tubo Minor H 5.3 Three-phase 230 15 150’ 240 86 lbs. 23” 11” Tubo Minor 12” yes
Grindex 4” Tubo Minor H 5.3 Three-phase 460 7.5 150’ 240 86 lbs. 23” 11” Tubo Minor 12” yes
Grindex 4” Tubo Major H 8.3 Three-phase 230 21 170’ 220 99 lbs. 23” 11” Tubo Major 12” yes
Grindex 4” Tubo Major H 8.3 Three-phase 460 10.6 170’ 220 99 lbs. 23” 11” Tubo Major 12” yes
KTZ33.7-60 KTZ67.5-60 KTZ47.5-60
Tubo Minor H
Tubo Major H
200
180
160
140
120
100
80
60
40
20
00 50 100 150 200 250 300 350 400 450 500 550
HD (f
t)
US GPM
Tsurumi Grindex
ot m o
n s a
n v n
14 866.877.6637 U.S. 866.766.3426 Canada www.aquascapeinc.com
This pond was a nightmare for decades, and
it’s now one of the main attractions
within the park.The City of Chicago
©2008 Aquascape, Inc., All Worldwide Rights Reserved
U.S.
Toll Free: (866) US-PONDS or (866) 877-6637
Customer Service Fax: (877) 329-2340
Technical Support Fax: (877) 329-2348
CANADA
Toll Free: (866) PONDH2O or (866) 766-3426O or (866)
Customer Service Fax: (905) 454-7310rvice Fax: (9
Item #29385IDD 07105883-ADI 070462
www.aquascapeinc.com