R Czt500 1500 v4 - Ritec

2
NUCLEAR RADIATION SEMICONDUCTOR DETECTORS AND ASSOCIATED ELECTRONICS CZT/500 and CZT/1500 Large Volume CdZnTe Detectors High efficiency Room temperature operation High energy resolution Wide detection energies range Gamma-radiation spectroscopy Portable and field spectrometers Environmental monitoring Nuclear industry Home land security Main Main Features Features Main Features Main Main Applications Applications Main Applications

Transcript of R Czt500 1500 v4 - Ritec

Page 1: R Czt500 1500 v4 - Ritec

NUCLEAR RADIATIONSEMICONDUCTOR DETECTORS

AND ASSOCIATED ELECTRONICS

CZT/500 and CZT/1500

Large Volume CdZnTe Detectors

High efficiency Room temperature operationHigh energy resolutionWide detection energies range

Gamma-radiation spectroscopyPortable and field spectrometersEnvironmental monitoringNuclear industryHome land security

Main

M

ain

F

eatu

res

Featu

res

Main

F

eatu

res

Main

M

ain

A

pp

licati

on

sA

pp

licati

on

sM

ain

A

pp

licati

on

s

Page 2: R Czt500 1500 v4 - Ritec

Large Volume CdZnTe Spectroscopy Detectors CZT/500 and CZT/1500

The CZT/500 and CZT/1500 are intended for application with miniature low noise charge sensitive preamplifiers PA101C or PA101C/HV or with other similar charge sensitive preamplifiers.

The CZT/500 and CZT/1500 are room temperature operating semiconductor CdZnTe gamma-radiation quasi-hemispherical detectors. Large sensitive volume of these detectors ensures high registration efficiency in a wide range of gamma-radiation energies.

These detectors are designed for application in portable spectrometers for various applications.

Detector Energy Resolution (FWHM)

at 662 keV, %*Peak-to-Compton Ratio

at 662 keV*

CZT/500CZT/1500

0.51.5

≤ 1500500≤ 2

2.5≤ 3.5≤

4.0≥ 3.5≥

DetectorVolume, cm³

BiasVoltage, V

Basic

• detector high voltage polarity positive• °range of recommended operation temperature at least 0 to 50 CDimensions• CZT/500 length (without connector) 33 mm

• CZT/1500

• detector type CdZnTe quasi-hemispherical detector

diameter 23 mm

length (without connector) 36 mm diameter 32 mmConnector

Weight

• CZT/500 BNC

• CZT/500 40 g• CZT/1500 70 g

• CZT/1500 SHV

Specifications

Spectroscopy Performance

152Spectrum of Eu registered by the CZT500.Detector volume 0.5 cm³.

Counts

1

10

1000

10000

100000

1000000

100

Channels0 500 1000 1500 2000

1408

keV

1458

keV

1528.7

keV

1213

keV

1113

keV

1085.9

keV

964

keV

867.4

keV

778.9

keV

444

keV

411

.1 k

eV

344.3

keV

244.7

keV

121.8

keV

41

keV

Uranium spectrum registered by the CZT500.Detector volume 0.5 cm³.

Channels0 300 400 500 600200100

10000

Counts

20000

30000

40000

50000

60000

0

205.2

keV

185.7

keV

163.4

keV

143.8

keV2

31

84

keV

T

h

231

58.6

keV

T

h

231

25.6

keV

T

h

U, T

h X

-rays

U, T

h X

-ra

ys

* measured at room temperature

ZRF Ritec SIAGustava Zemgala gatve 71A, Riga, LV-1039, Latviae-mail: [email protected]; web: www.ritec.lvtel./fax: +371-67543304