QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE...

12
FIXED POINT SUBSTRATE FIXING THERMOPAD FixU T, THICKNESS 5 mm art.No 05.001.5 WASHER THERMAL INSULATION LAYER BRACKET FixU T, FIXED SUPPORT art.No 02.ft.190 T PROFILE 80x60x2 mm art.No 01.2.80602.6 HPL PANEL FUNDERMAX 5,9(7 [ PP KHDG PP art.No 04.4.518.2 FLEXIBLE POINT 5,9(7 [ PP art.No 04.4.4812.1 CLADDING PANELS DRAWING RAINSCREEN SYSTEM EDITION _ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS. _ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT, SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND OPTIMIZATION. _ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE CLADDING PANELS HAVE TO BE SATISFIED. NOTES QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETS FUNDERMAX MAX EXTERIOR 01 HORIZONTAL SECTION JANUARY 2015

Transcript of QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE...

Page 1: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

FIXED POINT

SUBSTRATE

FIXING

THERMOPAD FixU T, THICKNESS 5 mmart.No 05.001.5

WASHER

THERMAL INSULATION LAYER

BRACKET FixU T, FIXED SUPPORTart.No 02.ft.190

T PROFILE 80x60x2 mmart.No 01.2.80602.6

HPL PANEL FUNDERMAX

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

FLEXIBLE POINT

RIVET Ø4.8x12 mmart.No 04.4.4812.1

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

01 HORIZONTAL SECTION

JANUARY 2015

Page 2: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

THERMOPAD FixU T, THICKNESS 5 mmart.No 05.001.5

BRACKET FixU T, FIXED SUPPORTart.No 02.ft.190

FIXING

RIVET Ø4.8x12 mmart.No 04.4.4812.1

RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

HPL PANEL FUNDERMAX

SUBSTRATE

THERMAL INSULATION LAYER

T PROFILE 80x60x2 mmart.No 01.2.80602.6

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

02 VERTICAL SECTION

JANUARY 2015

Page 3: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

SUBSTRATE

THERMAL INSULATION LAYER

HPL PANEL FUNDERMAX

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

FIXING

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

WASHER

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

L PROFILE 60x40x2 mmart.No 01.1.60402.6

RIVET Ø4.8x12 mmart.No 04.4.4812.1

EDITION

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

03 EXTERNAL CORNER

JANUARY 2015

Page 4: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

FIXING

THERMOPAD FixU T, THICKNESS 5 mmart.No 05.001.5

WASHER

BRACKET FixU T, FIXED SUPPORTart.No 02.ft.190

L PROFILE 60x40x2 mmart.No 01.1.60402.6

RIVET Ø4.8x12 mmart.No 04.4.4812.1

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

HPL PANEL FUNDERMAX

THERMAL INSULATION LAYER

SUBSTRATE

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

04 INTERNAL CORNER

JANUARY 2015

Page 5: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

SUBSTRATE

THERMAL INSULATION LAYER

T PROFILE 80x60x2 mmart.No 01.2.80602.6

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

HPL PANEL FUNDERMAX

SELF-DRILLING SCREW

L PROFILE 60x40x2 mmart.No 01.1.60402.6

L PROFILE 40x40x2 mmart.No 01.1.40402.6

PERFORATED ALUMINUIM SHEET

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

05 VERTICAL SECTION_FACADE BASE

JANUARY 2015

Page 6: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

ALUMINIUM SHEET

PERFORATED ALUMINIUM SHEET

L PROFILE 40x40x2 mmart.No 01.1.40402.6

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

HPL PANEL FUNDERMAX

RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU T, FIXED SUPPORTart.No 02.ft.190

THERMOPAD FixU T, THICKNESS 5 mmart.No 05.001.5

T PROFILE 80x60x2 mmart.No 01.2.80602.6

THERMAL INSULATION LAYER

SUBSTRATE

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

06 VERTICAL SECTION_ROOFBORDER COVER

JANUARY 2015

Page 7: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

SELF-DRILLING SCREW

FIXING

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

WASHER

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

L PROFILE 60x40x2 mmart.No 01.1.60402.6

HPL PANEL FUNDERMAX

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

THERMAL INSULATION LAYER

RIVET Ø4.8x12 mmart.No 04.4.4812.1

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

07.1 HORIZONTAL SECTION_WINDOW REVEAL

JANUARY 2015

Page 8: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

SELF-DRILLING SCREW

ALUMINIUM SHEET

FIXING

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

WASHER

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

L PROFILE 60x40x2 mmart.No 01.1.60402.6

RIVET Ø4.8x12 mmart.No 04.4.4812.1

HPL PANEL FUNDERMAX

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

THERMAL INSULATION LAYER

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

07.2 HORIZONTAL SECTION_WINDOW REVEAL

JANUARY 2015

Page 9: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

SUBSTRATE

THERMAL INSULATION LAYER

RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

T PROFILE 80x60x2 mmart.No 01.2.80602.6

HPL PANEL FUNDERMAX

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

L PROFILE 40x40x2 mmart.No 01.1.40402.6

PERFORATED ALUMINIUM SHEET

L PROFILE 60x40x2 mmart.No 01.1.60402.6

SELF-DRILLING SCREW CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

08.1 VERTICAL SECTION_WINDOW LINTEL

JANUARY 2015

Page 10: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

8.1

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

L PROFILE 40x40x2 mmart.No 01.1.40402.6

ALUMINIUM SHEET

SELF-DRILLING SCREW

SUBSTRATE

THERMAL INSULATION LAYER

RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

T PROFILE 80x60x2 mmart.No 01.2.80602.6

HPL PANEL FUNDERMAX

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

08.2 VERTICAL SECTION_WINDOW LINTEL

JANUARY 2015

Page 11: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

8.2RIVET Ø4.8x12 mmart.No 04.4.4812.1

FIXING

BRACKET FixU L, FLEXIBLE SUPPORTart.No 02.fl.190

THERMOPAD FixU L, THICKNESS 5 mmart.No 05.001.1

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

L PROFILE 60x40x2 mmart.No 01.1.60402.6

ALUMINIUM SHEET

HPL PANEL FUNDERMAX

T PROFILE 80x60x2 mmart.No 01.2.80602.6

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

08.3 VERTICAL SECTION_WINDOW LINTEL

JANUARY 2015

Page 12: QV1 MECHANICAL FASTENING SYSTEM USING VISIBLE RIVETSq-vent.eu/wp-content/uploads/2013/11/QV1-FUNDERMAX-RIVETED-1… · fundermax max exterior 03 external corner january 2015. fixing

ALUMINIUM SHEET

PERFORATED ALUMINIUM SHEET

L PROFILE 40x40x2 mmart.No 01.1.40402.6

RIVET Ø4.8x18 mm, head 16 mmart.No 04.4.518.2

HPL PANEL FUNDERMAX

FIXING

BRACKET FixU T, FIXED SUPPORTart.No 02.ft.190

THERMOPAD FixU T, THICKNESS 5 mmart.No 05.001.5

RIVET Ø4.8x12 mmart.No 04.4.4812.1

T PROFILE 80x60x2 mmart.No 01.2.80602.6

THERMAL INSULATION LAYER

SUBSTRATE

SELF-DRILLING SCREW

CLADDING PANELS

DRAWING

RAINSCREEN SYSTEM

EDITION

_ THE SPECIFICATION OF THE PROFILES, ACCESSORIES AND THEIR

POSITIONING, HAS TO BE AGREED UPON STATIC ANALYSIS.

_ THE STATIC ANALYSIS MUST BE APPLIED FOR EACH PROJECT

AND HAS TO RESPECT THE INDIVIDUALITY OF THE PROJECT,

SPECIFIC CONDITIONS AND LOCAL REGULATIONS. IT PROVIDES

SAFETY CHECK, VERIFICATION OF THE COMPONENTS AND

OPTIMIZATION.

_ ALL TECHNICAL REQUIREMENTS GIVEN BY THE SUPPLIER OF THE

CLADDING PANELS HAVE TO BE SATISFIED.

NOTES

QV1MECHANICAL FASTENING SYSTEMUSING VISIBLE RIVETS

FUNDERMAX MAX EXTERIOR

09 VERTICAL SECTION_WINDOW SILL

JANUARY 2015