TABLE I

ASTM D1761-06

QUICKSCREW WITHDRAWAL TEST

PROJECT NUMBER 111087C

TEST NUMBER MAXIMUM WITHDRAWAL

LOAD (LBF) MODE OF FAILURE

W-1 1244 Screw Pull-Out

W-2 1291 Screw Pull-Out

W-3 1318 Screw Pull-Out

W-4 1291 Screw Pull-Out

W-5 1214 Screw Pull-Out

AVERAGE 1272 ..

STANDARD DEVIATION 41.8 ..

Page 3: QUICKSCREW WITHDRAWAL TEST...ohammed aiyaz Laboratory Manager Page 1 of 3 Reviewed By: Pr Cln INCo Author Mohammed Faiyaz Created Date 2/28/2011 8:13:07 AM ...

Page 3 of 3

TABLE II

ASTM 2395-07a, METHOD A

SPECIFIC GRAVITY OF DOUGLAS FIR WOOD

PROJECT NUMBER 111087C

TEST NUMBER 1 2 AVERAGE

INITIAL WEIGHT (G) 64.7 67.3 ..

LENGTH (IN.) 3.50 3.49 ..

WIDTH (IN.) 1.96 1.94 ..

THICKNESS (IN.) 1.49 1.50 ..

OVEN-DRY WEIGHT (G) 59.0 61.2 ..

MOISTURE CONTENT (%) 9.7 10.0 9.8

SPECIFIC GRAVITY 0.352 0.368 0.360