Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150...
Transcript of Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150...
Product Safety Warnings The Smart Battery Switch (SBS) is only intended to be used as an engineering demon-
strator. It is not intended for extensive use or to be re-used in a product or system that is sold to consumers.
The SBS is intended to be used by electrical engineers who are experts in the field of high current design. If you are not qualified, seek the help of an expert before using the demonstrator.
Questions about the SBS should be directed to Infineon Application Engineering. The cable, cable lug, washer and nut used to connect to the bolt mounted onto the SBS
demonstrator’s circuit board must all be made of high current-capable metals which will not experience a significant temperature rise while conducting the current.
Battery Camping compliant to IEC 60095-2_Ed.4 (2009) The cable lug must be mounted directly to the bolt (torque 6Nm ±1Nm). Keep the current below 1800 A. The time a current may be applied is limited by
the temperature rise. Don‘t exceed 1 Joule of switching energy. Switching to high currents or to high switch off energy may destroy the switch and
the test setup and end up in fire.
Content Schematic How to connect the SBS
Quick Start GuideSmart Battery Switch (SBS) HW Version 3
Top
Bottom
R20
100 Ω/150 V/1%
D5IN414SW-13-F
R8
10 kΩ/150 V/1%
R19
560 Ω/150 V/1%
R9
1 kΩ/150 V/1%
R7
10 kΩ/150 V/1%
C2
10 nF/100 V/XJR
C4
220 nF/50 V/XJR
C3
10 nF/100 V/XJR
R1 … R6
100 Ω/150 V/1%
R21
10 kΩ/150 V/1%
R18
120 kΩ/150 V/1%
R16
100 Ω/150 V/1%
R22
10 kΩ/150 V/1%
R23
47 Ω/150 V/1%
Q1 … Q6
Voltage max.15 V
SupplyVoltage max. = 18 V
SupplyVoltage max. = 50 V
Q10BC807-25
LTC1154CS8
TSW-103-08-G-S
IC2
DesignatorSmartBatterySwitch_Main_SW_V30.SchDoc
Output Terminal
Battery Negative Terminal
Battery Positive Terminal
D3
PowerClamp
INT_VBB
INT_GND
D4 IN41
4SW
-13-
F D1 SZ1S
MA5
931B
TB
Drain
IN
ST
EN
Gate
Source
Q9
BC80
7-25
g_m
s1
2
3
GND SO
G
DS
VS
41
IN1
InGND
IN2
2
3
8
7
6
5
R13
680 Ω/150 V/1%
R15
120 kΩ/150 V/1%
R14
120 kΩ/150 V/1%
R17
120 kΩ/150 V/1%
C1LT6015IS5
U1A
g_freewh
Q7 ActiveFreewheeling
Q8 Wrong PolarityProtection
Q7IPLU300N04S4-R7
Q8IPLU300N04S4-R7
+IN
V+5
3
-IN OUT
V-
4
2
1
C1 = 100 nF/100 V/X7R
Schematic
R20
100 Ω/150 V/1%
D5IN414SW-13-F
R8
10 kΩ/150 V/1%
R19
560 Ω/150 V/1%
R9
1 kΩ/150 V/1%
R7
10 kΩ/150 V/1%
C2
10 nF/100 V/XJR
C4
220 nF/50 V/XJR
C3
10 nF/100 V/XJR
R1 … R6
100 Ω/150 V/1%
R21
10 kΩ/150 V/1%
R18
120 kΩ/150 V/1%
R16
100 Ω/150 V/1%
R22
10 kΩ/150 V/1%
R23
47 Ω/150 V/1%
Q1 … Q6
Voltage max.15 V
SupplyVoltage max. = 18 V
SupplyVoltage max. = 50 V
Q10BC807-25
LTC1154CS8
TSW-103-08-G-S
IC2
DesignatorSmartBatterySwitch_Main_SW_V30.SchDoc
Output Terminal
Battery Negative Terminal
Battery Positive Terminal
D3
PowerClamp
INT_VBB
INT_GND
D4 IN41
4SW
-13-
F D1 SZ1S
MA5
931B
TB
Drain
IN
ST
EN
Gate
Source
Q9
BC80
7-25
g_m
s
1
2
3
GND SO
G
DS
VS
41
IN1
InGND
IN2
2
3
8
7
6
5
R13
680 Ω/150 V/1%
R15
120 kΩ/150 V/1%
R14
120 kΩ/150 V/1%
R17
120 kΩ/150 V/1%
C1LT6015IS5
U1A
g_freewh
Q7 ActiveFreewheeling
Q8 Wrong PolarityProtection
Q7IPLU300N04S4-R7
Q8IPLU300N04S4-R7
+IN
V+5
3
-IN OUT
V-
4
2
1
C1 = 100 nF/100 V/X7R
www.infineon.com/smart-battery-switch
www.infineon.com/mosfet
Order Number: DEMO_BATT_SW_V3 SP001332050
© 2015 Infineon Technologies AG. All Rights Reserved.
SchematicQ1 … Q6 are in Parallel
R1
100 Ω/150 V/1%
D3P6SMB18CA
Q1
R3
100 Ω/150 V/1%
Q2
R4
100 Ω/150 V/1%
Q3
R5
100 Ω/150 V/1%
Q4
R11
100 Ω/150 V/1%
Q5
R12
100 Ω/150 V/1%
Q6
Gate Protection/Voltage max. = 18 V
In1InGNDIn2
BatteryNegativeTerminal
Output TerminalBattery Positive Terminal
How to Connect the SBS
IN1 IN2 Switch
N.C. N.C. On
L N.C. Off
N.C. L Off (latched)
N.C. Reset latched
N.C. = Not connectedL = Connected to InGND = Pull down In2 to InGND and release again
Thermal Image after 10 minutes and 250A.