Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150...

4
Product Safety Warnings The Smart Battery Switch (SBS) is only intended to be used as an engineering demon- strator. It is not intended for extensive use or to be re-used in a product or system that is sold to consumers. The SBS is intended to be used by electrical engineers who are experts in the field of high current design. If you are not qualified, seek the help of an expert before using the demonstrator. Questions about the SBS should be directed to Infineon Application Engineering. The cable, cable lug, washer and nut used to connect to the bolt mounted onto the SBS demonstrator’s circuit board must all be made of high current-capable metals which will not experience a significant temperature rise while conducting the current. Battery Camping compliant to IEC 60095-2_Ed.4 (2009) The cable lug must be mounted directly to the bolt (torque 6Nm ±1Nm). Keep the current below 1800 A. The time a current may be applied is limited by the temperature rise. Don‘t exceed 1 Joule of switching energy. Switching to high currents or to high switch off energy may destroy the switch and the test setup and end up in fire. Content Schematic How to connect the SBS Quick Start Guide Smart Battery Switch (SBS) HW Version 3 Top Bottom

Transcript of Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150...

Page 1: Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150 V/ 1% Q5 R 12 100 Ω/150 V/ 1% Q6 Gate Protection/Voltage max. = 18 V In1 InGND

Product Safety Warnings The Smart Battery Switch (SBS) is only intended to be used as an engineering demon-

strator. It is not intended for extensive use or to be re-used in a product or system that is sold to consumers.

The SBS is intended to be used by electrical engineers who are experts in the field of high current design. If you are not qualified, seek the help of an expert before using the demonstrator.

Questions about the SBS should be directed to Infineon Application Engineering. The cable, cable lug, washer and nut used to connect to the bolt mounted onto the SBS

demonstrator’s circuit board must all be made of high current-capable metals which will not experience a significant temperature rise while conducting the current.

Battery Camping compliant to IEC 60095-2_Ed.4 (2009) The cable lug must be mounted directly to the bolt (torque 6Nm ±1Nm). Keep the current below 1800 A. The time a current may be applied is limited by

the temperature rise. Don‘t exceed 1 Joule of switching energy. Switching to high currents or to high switch off energy may destroy the switch and

the test setup and end up in fire.

Content Schematic How to connect the SBS

Quick Start GuideSmart Battery Switch (SBS) HW Version 3

Top

Bottom

Page 2: Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150 V/ 1% Q5 R 12 100 Ω/150 V/ 1% Q6 Gate Protection/Voltage max. = 18 V In1 InGND

R20

100 Ω/150 V/1%

D5IN414SW-13-F

R8

10 kΩ/150 V/1%

R19

560 Ω/150 V/1%

R9

1 kΩ/150 V/1%

R7

10 kΩ/150 V/1%

C2

10 nF/100 V/XJR

C4

220 nF/50 V/XJR

C3

10 nF/100 V/XJR

R1 … R6

100 Ω/150 V/1%

R21

10 kΩ/150 V/1%

R18

120 kΩ/150 V/1%

R16

100 Ω/150 V/1%

R22

10 kΩ/150 V/1%

R23

47 Ω/150 V/1%

Q1 … Q6

Voltage max.15 V

SupplyVoltage max. = 18 V

SupplyVoltage max. = 50 V

Q10BC807-25

LTC1154CS8

TSW-103-08-G-S

IC2

DesignatorSmartBatterySwitch_Main_SW_V30.SchDoc

Output Terminal

Battery Negative Terminal

Battery Positive Terminal

D3

PowerClamp

INT_VBB

INT_GND

D4 IN41

4SW

-13-

F D1 SZ1S

MA5

931B

TB

Drain

IN

ST

EN

Gate

Source

Q9

BC80

7-25

g_m

s1

2

3

GND SO

G

DS

VS

41

IN1

InGND

IN2

2

3

8

7

6

5

R13

680 Ω/150 V/1%

R15

120 kΩ/150 V/1%

R14

120 kΩ/150 V/1%

R17

120 kΩ/150 V/1%

C1LT6015IS5

U1A

g_freewh

Q7 ActiveFreewheeling

Q8 Wrong PolarityProtection

Q7IPLU300N04S4-R7

Q8IPLU300N04S4-R7

+IN

V+5

3

-IN OUT

V-

4

2

1

C1 = 100 nF/100 V/X7R

Schematic

Page 3: Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150 V/ 1% Q5 R 12 100 Ω/150 V/ 1% Q6 Gate Protection/Voltage max. = 18 V In1 InGND

R20

100 Ω/150 V/1%

D5IN414SW-13-F

R8

10 kΩ/150 V/1%

R19

560 Ω/150 V/1%

R9

1 kΩ/150 V/1%

R7

10 kΩ/150 V/1%

C2

10 nF/100 V/XJR

C4

220 nF/50 V/XJR

C3

10 nF/100 V/XJR

R1 … R6

100 Ω/150 V/1%

R21

10 kΩ/150 V/1%

R18

120 kΩ/150 V/1%

R16

100 Ω/150 V/1%

R22

10 kΩ/150 V/1%

R23

47 Ω/150 V/1%

Q1 … Q6

Voltage max.15 V

SupplyVoltage max. = 18 V

SupplyVoltage max. = 50 V

Q10BC807-25

LTC1154CS8

TSW-103-08-G-S

IC2

DesignatorSmartBatterySwitch_Main_SW_V30.SchDoc

Output Terminal

Battery Negative Terminal

Battery Positive Terminal

D3

PowerClamp

INT_VBB

INT_GND

D4 IN41

4SW

-13-

F D1 SZ1S

MA5

931B

TB

Drain

IN

ST

EN

Gate

Source

Q9

BC80

7-25

g_m

s

1

2

3

GND SO

G

DS

VS

41

IN1

InGND

IN2

2

3

8

7

6

5

R13

680 Ω/150 V/1%

R15

120 kΩ/150 V/1%

R14

120 kΩ/150 V/1%

R17

120 kΩ/150 V/1%

C1LT6015IS5

U1A

g_freewh

Q7 ActiveFreewheeling

Q8 Wrong PolarityProtection

Q7IPLU300N04S4-R7

Q8IPLU300N04S4-R7

+IN

V+5

3

-IN OUT

V-

4

2

1

C1 = 100 nF/100 V/X7R

Page 4: Quick Start Guide - mouser.cn · Q2 R 4 100 Ω/150 V/ 1% Q3 R 5 100 Ω/150 V/ 1% Q4 R 11 100 Ω/150 V/ 1% Q5 R 12 100 Ω/150 V/ 1% Q6 Gate Protection/Voltage max. = 18 V In1 InGND

www.infineon.com/smart-battery-switch

www.infineon.com/mosfet

Order Number: DEMO_BATT_SW_V3 SP001332050

© 2015 Infineon Technologies AG. All Rights Reserved.

SchematicQ1 … Q6 are in Parallel

R1

100 Ω/150 V/1%

D3P6SMB18CA

Q1

R3

100 Ω/150 V/1%

Q2

R4

100 Ω/150 V/1%

Q3

R5

100 Ω/150 V/1%

Q4

R11

100 Ω/150 V/1%

Q5

R12

100 Ω/150 V/1%

Q6

Gate Protection/Voltage max. = 18 V

In1InGNDIn2

BatteryNegativeTerminal

Output TerminalBattery Positive Terminal

How to Connect the SBS

IN1 IN2 Switch

N.C. N.C. On

L N.C. Off

N.C. L Off (latched)

N.C. Reset latched

N.C. = Not connectedL = Connected to InGND = Pull down In2 to InGND and release again

Thermal Image after 10 minutes and 250A.