Quick Reference MD1230/MP1590 Family Data Quality Analyzer/IP Network Analyzer/ Network Performance Tester

Transcript of Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1...

Page 1: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

Quick Reference

MD1230/MP1590 Family

Data Quality Analyzer/IP Network Analyzer/

Network Performance Tester

Page 2: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division1

MD1230/MP1590 Family version 7.0MD1230/MP1590 Family version 7.0Quick Start GuideQuick Start Guide

MBPMBP--1SG0603671SG060367--0000

First edition

IP Network Measurement DivisionAnritsu Corporation

IP Network Measurement Division2

>10 cm

MD1230B SetupMD1230B SetupPlace the MD1230B on a safe stable surface.

Leave at least 10 cm of space around the sides of the MD1230B for sufficient cooling ventilation.

Supply power of 100 to 115 Vac or 220 to 240 Vac at a frequency of 47.5 to 63 Hz. The maximum power consumption is 600 VA.

1

Page 3: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division3

The MD1230B and MP1591A both have a power switch on the front panel. The MD1231A1 has a power switch on the side.

Turning power on (1) Connect the power cord.(2) Turn on the main power switch.

Turning power off (1) Before turning off the MD1230B and MD1231A1, always quit the main

application in the same way as a PC and then turn off the main power switch.(2) To shut down the MP1591A just turn off the main power switch.

Power Switch

PowerPower--on/Poweron/Power--offoff

IP Network Measurement Division4

Measurement FlowMeasurement Flow

1. Setup2. Setting Reservation and Port (Common Settings)3. Connecting DUT4. Physical Layer Measurements

(Link Test, Clock Measurement)5. BER Measurement6. QoS Test

Setting Tx Stream, Counter, and Multi-flow counter7. Setting Grouping

This presentation explains setup using the MU120131A/132A modules.Replace the other modules properly when measuring with them.

2

Page 4: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division5

Before Measurement Before Measurement –– Installing Version 7.0Installing Version 7.0

Refer to the “MD1230 Family Upgrade Manual” for the software upgrade procedure.

*Update the firmware, confirm the installation, and *Update the firmware, confirm the installation, and connect as described in the connect as described in the ““MD1230 Family Upgrade MD1230 Family Upgrade Manual.Manual.””

*Before upgrading, save the settings if you want to *Before upgrading, save the settings if you want to keep the settings from the previous version.keep the settings from the previous version.

IP Network Measurement Division6

1. Setup1. SetupThe Selector screen is displayed after power-on.

Click “Main application.”(The measurement screen appears automatically after 15 seconds.)

3

Page 5: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division7

2. Common Settings 2. Common Settings –– ReservationReservationReserve the port used for measurement before starting measurement.

Right-click “Unit1” and select “Reservation... .” The module ports can be selected (see below).Put checkmarks at the ports to be reserved or click the “Check all” button.

IP Network Measurement Division8

2. Common Setting 2. Common Setting –– Port SettingPort SettingAfter port reservation, go to port setting.

Right-click “Port 1 (Unit1:4:1)” and select “Port Setting…”Open the “IPv4” screen, set the “IPv4 Address:”, “Netmask:”, and “Gateway:”. (Each value is proper. In this example “192.168.0.1”, “255.255.255.0”, and “192.168.0.255” are set.)

Check “Reply to this port ARP request”and “Reply to this port PING request”when using ARP and PING.Set “MAC Address:” (The value is proper. “00-00-00-01-04-01” referring to Unit1:4:1 is set in this example.)

4

Page 6: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division9

2. Common Setting 2. Common Setting –– Port SettingPort Setting

Open the “VLAN" screen and input a value in “TPID (hex)" when there are frames with VLAN Tags on the network. Select “Through[Port1-Port2]”at “Mode:” when measuring in Through mode. (Here, the setting is “Normal.”)

*The check boxes for “Enabled” and “Only VLAN Tagged Frames” are no longer displayed with MU120121A/22A versions 4.1/4.2/5.0/6.0.

IP Network Measurement Division10

2. Common Setting 2. Common Setting –– Port SettingPort Setting

Set “Auto Negotiation” to On. For the MU120131A, put checkmarks in all the “Capabilities To Be Advertised” checkboxes, and in “Auto MDA/MDI-X.”Set “Test Pattern” to “Cross PRBS 31.”

*Measure the E-PON frames at MU120132A by checking “Preamble” and “E-PON.”*Set “Test Pattern” to both “Single PRBS9” and “PRBS23/31.”

MU120131A Screen MU120132A Screen

5

Page 7: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division11

2. Common Setting 2. Common Setting –– Port SettingPort Setting

**The MU120122A The MU120122A ““Optical SendOptical Send”” function function changes to the changes to the ““Physical I/FPhysical I/F”” screen.screen.(The MU120121A also has the “Physical I/F” screen .)

Version 5.0/6.0 Screen

Set the other ports to the same settings.

IP Network Measurement Division12

3. Connecting DUT3. Connecting DUT

DUT

Direct Test

Frame Forwarding Test DUT

Tx

Rx

Connect the DUT. (Select the frame generation test setting.)

Network

Through mode

Connect Port1 of the MD1230B and the DUT at the direct test (or 1-port monitoring).

DUTDUTMonitoring

Connect Port1/2 of the MD1230B and the Rx/Tx Port of the DUT at the frame forwarding test.

Connect Port1/2 of the MD1230B between the DUT, and set the through mode at monitoring.

6

Page 8: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division13

See Each MeasurementSee Each Measurement

Physical Layer Measurement - Link Test

Physical Layer Measurement - Clock Measurement

Physical Layer Measurement - PoE Check

BER Measurement

QoS Test

Slide 14Slide 14Go to ...

Slide 27Slide 27Go to ...

Slide 30Slide 30Go to ...

Slide 31Slide 31Go to ...

Slide 33Slide 33Go to ...

IP Network Measurement Division14

4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink TestLink test at Link Up/Down

Link flap

DUT

Link up

Link down

Link up(On)

Link down(Off)

Loop count

Link checkerThe MD1230B can use the monitoring link status and displays link errors.

MU120131A/32AMU120131A/32A

7

Page 9: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division15

4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink TestThe Link Up/Down test is performed at the Physical I/F screen.

MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A

MU120121A Screen

MU120131A Screen

Switch Link Up/Down manually, and confirm the DUT behavior.

*The Link Up/Down test and the Link Flap test can be done at the MU120131/32A.

Confirm that the link is normal when Link Up/Down is repeated 100 times by using the Flap function at On/Off intervals of 10 s and 1 s, respectively.

*Manual can also be selected for Link Up/Down at the MU120121A.

IP Network Measurement Division16

4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink Test

Set “No/Go Check” to On, and start the test at “Flap Setting.”

OK Example

*The MD1230B displays OK at “Status:” when the Link is connected. It displays NG and stops the count when the Link is restored.

MU120131A/32AMU120131A/32A

NG Example

8

Page 10: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division17

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation AnalysisAuto-Negotiation Analysis at MU120112A/22A/32A

Option-15Option-15

Auto-Negotiation AnalysisAuto-Negotiation Analysis Code Data TransmissionCode Data Transmission

Link Timer TestLink Timer Test

Port1

Port 1Through Mode

Port 1 Port 2

Port 2 Port 1

Confirming auto-negotiation sequenceConfirming interoperabilityTroubleshooting

Confirming auto-negotiation sequenceChecking illegal code reception

Confirming operation by changing auto-negotiation time

IP Network Measurement Division18

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation AnalysisClick “Setup Utility”at the Selector screen when performing Auto-Negotiation Analysis at MU120112A.

Setup Utility

Select the operation mode using the pull-down menu.

Open “Firmware Functionality” and select “Auto Negotiation” for the slot.Click the Apply button, exit the Setup Utility, and open the Main Application.

*This procedure is not necessary at MU120122A/32A.

Option-15Option-15

9

Page 11: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division19

4. Link Test 4. Link Test –– Link Timer TestLink Timer TestConfirm the inter-operativity for the DUT Link Timer by changing the Link Timer value.

Right-click Port1(Unit1:5:1) at the MU120132A and select “Port Setting...”Check “Timeout Enable” at “Auto Negotiation.” Check “Change Link Timer:”and set the value to 0 to 100 ms.

*The link becomes enable/not enable as the Link Timer value is changed gradually between 0 and 100 ms. The standard is 10 to 20 ms.

IP Network Measurement Division20

Capture and Decode

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

List of captured data

Start/Stop

Shows decodeddata in these fields

Select capture port

Decodes captured auto-negotiation data Analyze both protocoland data levels on one screen to check inter-operability

10

Page 12: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division21

Determines Negotiation States Automatically

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

Determines auto-negotiationstate for each device from captured dataMakes checking auto-negotiation function easy

DUT-ADUT-B

MD1230B

IP Network Measurement Division22

Trigger Setting Screen Filter

Efficient Troubleshooting

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

Captures auto-negotiation data only when changesTrigger and filter functions help select only important dataSolves auto-negotiation problems quickly and efficiently

11

Page 13: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division23

Changing MII Registers During Capture

MII Registers

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

ChangeMII Registers

Data Capture

DUTMD1230B

Change MII Registersduring captureControl registers such asPHY Reset and RestartAuto-Negotiation withoutdisconnecting fibers

IP Network Measurement Division24

DUT-AMD1230B

Port1

Auto-Negotiation Sequence Generator

• Generate auto-negotiation code data• Create sequences of up to 256 patterns• Capture and analyze auto-negotiation data simultaneously• Perform abnormal data tests

• Generate auto-negotiation code data• Create sequences of up to 256 patterns• Capture and analyze auto-negotiation data simultaneously• Perform abnormal data tests

Transmitauto-negotiation data

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

12

Page 14: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division25

Edit Auto-Negotiation Sequence Code Data

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

Transmitting On/Off

Choose transmitting pattern

Transmit up to 256 code data patternsSelect “Code Data” from pull-down menuin Send Data edit screenCreate code data sequences quickly andeasily

IP Network Measurement Division26

Example

4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15

DUT

Transmit code data

Capture and analyze code data

Transmit auto-negotiation test sequenceCheck response sequence

Transmit abnormal auto-negotiation sequenceCheck response under abnormal conditions

MD1230B

13

Page 15: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division27

4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock Measurement

The Clock Measurement functionThe Clock Measurement function is used to confirm that the DUT clock is within ±100 ppm.The Clock Variation functionThe Clock Variation function is used to monitor the DUT behavior when the clock speed is changed.

DUT DUT

Tx

Rx

MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01

Manual Link Test–100 ppm OK?+100 ppm OK?

Manual Forwarding TestTx –100 ppm Rx –100 ppm OK?Tx +100 ppm Rx –100 ppm OK?Tx –100 ppm Rx +100 ppm OK?Tx +100 ppm Rx +100 ppm OK?

Link Test Frame Forwarding Test

IP Network Measurement Division28

4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock MeasurementClock Measurement is performed at the Physical I/F Screen.

MU120121A Screen

MU120131A Screen (with Opt. 01)

*The clock measurement function is added at the MU120121A/22A.

① Confirm the clock is within ±100 ppm.

Supports monitoring of clock counters for several ports.Supports monitoring log function.

MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01

14

Page 16: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division29

4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock Measurement

② Changing the clock at the clock tolerance test confirms whether an error or link down occurs.

②*Two values can be set for one module at the MU120131/32A.Select clock 1 or 2 for Port 1-4, Port 5-8, and Port 9-12 at the MU120131A and for Port 1-4, and Port 5-8 at the MU120132A.

*The MU120121/22A “Clock Variation”function is moved to this screen.

MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01

MU120121A Screen

MU120131A Screen (with Opt.01)

Clock Measurement is performed at the Physical I/F Screen.

IP Network Measurement Division30

4. Physical Layer Measurement 4. Physical Layer Measurement –– PoE CheckPoE CheckThe PoE check is performed at the MU120131A.

Checking PoE confirms the status of power from PoE ports.MU120131A-02MU120131A-02

MU120131A Screen (with Opt. 02)

0 to 30 V: Off (0 – 30 V)31 to 42 V: Under (31 – 42 V)43 V: Normal (43 V ~)

0 to 30 V: Off (0 – 30 V)31 to 42 V: Under (31 – 42 V)43 V: Normal (43 V ~)

15

Page 17: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division31

5. BER Measurement 5. BER Measurement –– Packet BERPacket BER

Packet BER MeasurementThe Data field of the Ethernet frame at the Tx side is filled with a PRBS pattern and the BER is calculated at the Rx side.Bit error insertion

Preamble8 bytes

FCS4 bytes

DataSingle PRBS9

Cross PRBS23, 31

IFG12 bytesHeader

DUT

Rate/Programmable rate

Option-11Option-11

Error Insertion

IP Network Measurement Division32

5. BER Measurement 5. BER Measurement –– Error InsertionError InsertionBER is measured during error insertion at the Error Insertion Screen.

Set “Cross PRBS Error” for “Type.”Set “Programmed Rate” for “Timing,”and 1.0E-9 as “Programmed Rate.”Insert the error by clicking the [Error] button.

*Select the Line Error at this screen.

Option-11Option-11

16

Page 18: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division33

6. QoS Measurement6. QoS Measurement

QoS Measurement

QoS TestChecking traffic priority control systemChecking quality of each client dataChecking total performance of network

QoS TestChecking traffic priority control systemChecking quality of each client dataChecking total performance of network

40 Mbit/s

QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut

20 Mbit/s

ID1: 10MID2: 10MID3: 10MID4: 10M

ID1:10MID2:5MID3:5MID4:0M

Priority Control

IP Network Measurement Division34

6. QoS Measurement 6. QoS Measurement –– Tx Stream Tx Stream –– Frame SettingFrame SettingCreate the stream by clicking “Add” at “Tx Stream.”

Edit the stream by clicking the “Edit...”button. Set “Frame Length” at “General”of “Frame Setting.”Check “VLAN,” and click the “Edit...”button. If “User priority” is too high, data may be discarded due to traffic overflow.

17

Page 19: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division35

6. QoS Measurement 6. QoS Measurement –– Tx Stream Tx Stream –– Stream SettingStream SettingSelect “Continuous” at “Distribution:” of “Stream Control.”

Set "Inter Frame Gap:" to the value where traffic overflow occurs.

IP Network Measurement Division36

6. QoS Measurement 6. QoS Measurement –– CounterCounterClick the “Display Option” button, and set the counter display.

* The display items can be changed up/down.

*The default display is three settings.*The counter display can be either

Current or Accumulated or both Current and Accumulated.

Check the PoE Alarm at the PoE alarm count.E-PON frame errors can be counted by checking “Preamble CRC Error.”

18

Page 20: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division37

6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter

40 Mbit/s

QoS ControlID1: 10 MbpsID2: Best EffortID3: Best EffortID4: 100% cut

20 Mbit/s

ID1: 10MID2: 10MID3: 10MID4: 10M

ID1:10MID2:5MID3:5MID4:0M

The Counter Screen include Multi-flow counter at the MU120131A/32A.

MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A

Flows: 256Flow Condition: Up to 4 IDs (16 bits x 4)Measurement: Transmit/Receive frames

Transmit/Receive bitsRateLatencySequence error

Priority Control

The main frame supports up to 256 flows in real time.Other flows are measured statistically.

IP Network Measurement Division38

6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A

40 Mbit/s

QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut 20 Mbit/s

ID1: 10MID2: 10MID3: 10MID4: 10M

ID1:10MID2:5MID3:5MID4:0M

Step 1Flow ID Setting

Priority Control

Step 1Flow ID Setting

Set IP address of ID1 to ID4 as Flow filtering ID

19

Page 21: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division39

6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A

40 Mbit/s

QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut 20 Mbit/s

ID1: 10MID2: 10MID3: 10MID4: 10M

ID1:10MID2:5MID3:5MID4:0M

Priority Control

Check throughput of each flow using table view.

Step 2Flow measurementStep 2Flow measurement

Check throughput of each flow using graph view.

Check latency of each flow.

ID1 >ID2 >ID3 >ID4 >

IP Network Measurement Division40

7. Setting Grouping7. Setting GroupingSetting the grouping supports transmitting/receiving between anycombination of multiple ports in the same way as the RFC2544 auto-test.

Measurement can be performed as Fully Meshed, Partially Meshed, or One to One.

Fully Meshed Partially Meshed One to One

*Can be used for checking all ports of DUT

*Can also be used for multiple measurements per port (multicast and PON measurement, etc.)

*Used for multiple simultaneous transmitting at one to one combination.

20

Page 22: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division41

Other FunctionsOther Functions

Arrival Time Variation/Latency VariationProtocol Emulation, etc.

Ch2

Server (Encode) Client (Decode)

R

SW

Latency Variation

Latency histogram screen

Display variation in network latency as histogramChecking traffic fluctuationChecking fluctuation of filtered Flow/Service

IP Network Measurement Division42

Utility FunctionsUtility Functions

21

Page 23: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division43

Report FunctionReport Function

New Pause function

HTML-format report file (displayed and printed at external PC)

*Supports Counter, Multi-flow counter, Latency, Capture, RFC2544, RFC2889 (Measurement results saved as graph with measurement conditions for later analysis)

*New Pause function assists results saving during measurement.

IP Network Measurement Division44

The configuration of the units controlled by this software and their functions are displayed at the Tree ViewTree View on the left of the screen.Unit and port settings and group input can be performed in the Tree ViewTree View.

Click the Tree View iconTree View icon or press the Tree View keyTree View keyon front panel to toggle the Tree View on and off.

Tree ViewTree View

22

Page 24: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division45

(1) Save and Load Measurement Conditions and ResultsAfter stopping measurement, click the FD icon at the top of the window to save measurement conditions and results. This function cannot be used during measurement, transmission, counting capturing, etc.

(2) Save and load procedure

a. Stop all measurements.b. Select save/load target in

Tree View.c. Select “Save…” or “Load…”d. Select the destination.e. Select the item to save or load.f. Click Execute.

Save/load target;Unit: All modules, All portsModule: Port in selected modulePort: Selected port

An error will occur if the user does not select the same load target condition as the save target condition.

Save/load target;Unit: All modules, All portsModule: Port in selected modulePort: Selected port

An error will occur if the user does not select the same load target condition as the save target condition.

Save and LoadSave and Load

IP Network Measurement Division46

Save and Load Save and Load –– Speed UpSpeed Up

The speed of batch Save and Load for the Stream setting for all ports has been increased.

*A binary image transfer function has been added to the previous text file output. *This is useful for customers with multiple stream settings.

23

Page 25: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

IP Network Measurement Division47

(1) PrintingClick the Printer icon at the top right of the window and select “Print… .”Next, select the print target and Click “Print.”Items that can be printed change according to the displayed screen.

Print and Screen CopyPrint and Screen Copy

(1)

File format: Bitmap or JPEG

Select the output destination.

(2)

(2) Screen CopyClick the Printer icon at the top right of the window and select “Screen Copy Setting.”Next, set the file destination and format.Press the Screen Copy key on the front panel to save the current screen.

IP Network Measurement Division48

EndEndThank you.Thank you.

24

Page 26: Quick Reference MD1230/MP1590 Family · 2017. 12. 13. · IP Network Measurement Division 1 MD1230/MP1590 Family version 7.0 Quick Start Guide MBP-1SG060367-00 First edition IP Network

Anritsu Corporation5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 JapanPhone: +81-46-223-1111Fax: +81-46-296-1264

• U.S.A.Anritsu Company1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A.Toll Free: 1-800-267-4878Phone: +1-972-644-1777Fax: +1-972-671-1877

• CanadaAnritsu Electronics Ltd.700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, CanadaPhone: +1-613-591-2003 Fax: +1-613-591-1006

• Brazil Anritsu Eletrônica Ltda.Praca Amadeu Amaral, 27 - 1 Andar01327-010-Paraiso-São Paulo-BrazilPhone: +55-11-3283-2511Fax: +55-11-3288-6940

• U.K.Anritsu EMEA Ltd.200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.Phone: +44-1582-433200 Fax: +44-1582-731303

• FranceAnritsu S.A.9 Avenue du Québec, Z.A. de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1-60-92-15-50Fax: +33-1-64-46-10-65

• GermanyAnritsu GmbHNemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55

• ItalyAnritsu S.p.A.Via Elio Vittorini 129, 00144 Roma, ItalyPhone: +39-6-509-9711 Fax: +39-6-502-2425

• SwedenAnritsu ABBorgafjordsgatan 13, 164 40 KISTA, SwedenPhone: +46-8-534-707-00 Fax: +46-8-534-707-30

• FinlandAnritsu ABTeknobulevardi 3-5, FI-01530 VANTAA, FinlandPhone: +358-20-741-8100Fax: +358-20-741-8111

• DenmarkAnritsu A/SKirkebjerg Allé 90, DK-2605 Brøndby, DenmarkPhone: +45-72112200Fax: +45-72112210

• SpainAnritsu EMEA Ltd. Oficina de Representación en EspañaEdificio VeganovaAvda de la Vega, n˚ 1 (edf 8, pl 1, of 8)28108 ALCOBENDAS - Madrid, SpainPhone: +34-914905761Fax: +34-914905762

• United Arab EmiratesAnritsu EMEA Ltd.Dubai Liaison OfficeP O Box 500413 - Dubai Internet CityAl Thuraya Building, Tower 1, Suit 701, 7th FloorDubai, United Arab EmiratesPhone: +971-4-3670352Fax: +971-4-3688460

• SingaporeAnritsu Pte. Ltd.10, Hoe Chiang Road, #07-01/02, Keppel Towers,Singapore 089315 Phone: +65-6282-2400 Fax: +65-6282-2533

• IndiaAnritsu Pte. Ltd. India Branch OfficeUnit No. S-3, Second Floor, Esteem Red Cross Bhavan,No. 26, Race Course Road, Bangalore 560 001, IndiaPhone: +91-80-32944707Fax: +91-80-22356648

• P.R. China (Hong Kong)Anritsu Company Ltd.Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East,Kowloon, Hong KongPhone: +852-2301-4980Fax: +852-2301-3545

• P.R. China (Beijing)Anritsu Company Ltd.Beijing Representative OfficeRoom 1515, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 10004, P.R. ChinaPhone: +86-10-6590-9230Fax: +86-10-6590-9235

• KoreaAnritsu Corporation, Ltd.8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, KoreaPhone: +82-2-553-6603Fax: +82-2-553-6604

• AustraliaAnritsu Pty. Ltd.Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, AustraliaPhone: +61-3-9558-8177Fax: +61-3-9558-8255

• TaiwanAnritsu Company Inc.7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, TaiwanPhone: +886-2-8751-1816Fax: +886-2-8751-1817

Specifications are subject to change without notice.

No.MD1230_MP1590-E-T-1-(1.00) Printed in Japan 2007-3 ADK

Please Contact:

070207

Printed on 70% Recycled Paper