Quick Reference
MD1230/MP1590 Family
Data Quality Analyzer/IP Network Analyzer/
Network Performance Tester
IP Network Measurement Division1
MD1230/MP1590 Family version 7.0MD1230/MP1590 Family version 7.0Quick Start GuideQuick Start Guide
MBPMBP--1SG0603671SG060367--0000
First edition
IP Network Measurement DivisionAnritsu Corporation
IP Network Measurement Division2
>10 cm
MD1230B SetupMD1230B SetupPlace the MD1230B on a safe stable surface.
Leave at least 10 cm of space around the sides of the MD1230B for sufficient cooling ventilation.
Supply power of 100 to 115 Vac or 220 to 240 Vac at a frequency of 47.5 to 63 Hz. The maximum power consumption is 600 VA.
1
IP Network Measurement Division3
The MD1230B and MP1591A both have a power switch on the front panel. The MD1231A1 has a power switch on the side.
Turning power on (1) Connect the power cord.(2) Turn on the main power switch.
Turning power off (1) Before turning off the MD1230B and MD1231A1, always quit the main
application in the same way as a PC and then turn off the main power switch.(2) To shut down the MP1591A just turn off the main power switch.
Power Switch
PowerPower--on/Poweron/Power--offoff
IP Network Measurement Division4
Measurement FlowMeasurement Flow
1. Setup2. Setting Reservation and Port (Common Settings)3. Connecting DUT4. Physical Layer Measurements
(Link Test, Clock Measurement)5. BER Measurement6. QoS Test
Setting Tx Stream, Counter, and Multi-flow counter7. Setting Grouping
This presentation explains setup using the MU120131A/132A modules.Replace the other modules properly when measuring with them.
2
IP Network Measurement Division5
Before Measurement Before Measurement –– Installing Version 7.0Installing Version 7.0
Refer to the “MD1230 Family Upgrade Manual” for the software upgrade procedure.
*Update the firmware, confirm the installation, and *Update the firmware, confirm the installation, and connect as described in the connect as described in the ““MD1230 Family Upgrade MD1230 Family Upgrade Manual.Manual.””
*Before upgrading, save the settings if you want to *Before upgrading, save the settings if you want to keep the settings from the previous version.keep the settings from the previous version.
IP Network Measurement Division6
1. Setup1. SetupThe Selector screen is displayed after power-on.
Click “Main application.”(The measurement screen appears automatically after 15 seconds.)
3
IP Network Measurement Division7
2. Common Settings 2. Common Settings –– ReservationReservationReserve the port used for measurement before starting measurement.
Right-click “Unit1” and select “Reservation... .” The module ports can be selected (see below).Put checkmarks at the ports to be reserved or click the “Check all” button.
IP Network Measurement Division8
2. Common Setting 2. Common Setting –– Port SettingPort SettingAfter port reservation, go to port setting.
Right-click “Port 1 (Unit1:4:1)” and select “Port Setting…”Open the “IPv4” screen, set the “IPv4 Address:”, “Netmask:”, and “Gateway:”. (Each value is proper. In this example “192.168.0.1”, “255.255.255.0”, and “192.168.0.255” are set.)
Check “Reply to this port ARP request”and “Reply to this port PING request”when using ARP and PING.Set “MAC Address:” (The value is proper. “00-00-00-01-04-01” referring to Unit1:4:1 is set in this example.)
4
IP Network Measurement Division9
2. Common Setting 2. Common Setting –– Port SettingPort Setting
Open the “VLAN" screen and input a value in “TPID (hex)" when there are frames with VLAN Tags on the network. Select “Through[Port1-Port2]”at “Mode:” when measuring in Through mode. (Here, the setting is “Normal.”)
*The check boxes for “Enabled” and “Only VLAN Tagged Frames” are no longer displayed with MU120121A/22A versions 4.1/4.2/5.0/6.0.
IP Network Measurement Division10
2. Common Setting 2. Common Setting –– Port SettingPort Setting
Set “Auto Negotiation” to On. For the MU120131A, put checkmarks in all the “Capabilities To Be Advertised” checkboxes, and in “Auto MDA/MDI-X.”Set “Test Pattern” to “Cross PRBS 31.”
*Measure the E-PON frames at MU120132A by checking “Preamble” and “E-PON.”*Set “Test Pattern” to both “Single PRBS9” and “PRBS23/31.”
MU120131A Screen MU120132A Screen
5
IP Network Measurement Division11
2. Common Setting 2. Common Setting –– Port SettingPort Setting
**The MU120122A The MU120122A ““Optical SendOptical Send”” function function changes to the changes to the ““Physical I/FPhysical I/F”” screen.screen.(The MU120121A also has the “Physical I/F” screen .)
Version 5.0/6.0 Screen
Set the other ports to the same settings.
IP Network Measurement Division12
3. Connecting DUT3. Connecting DUT
DUT
Direct Test
Frame Forwarding Test DUT
Tx
Rx
Connect the DUT. (Select the frame generation test setting.)
Network
Through mode
Connect Port1 of the MD1230B and the DUT at the direct test (or 1-port monitoring).
DUTDUTMonitoring
Connect Port1/2 of the MD1230B and the Rx/Tx Port of the DUT at the frame forwarding test.
Connect Port1/2 of the MD1230B between the DUT, and set the through mode at monitoring.
6
IP Network Measurement Division13
See Each MeasurementSee Each Measurement
Physical Layer Measurement - Link Test
Physical Layer Measurement - Clock Measurement
Physical Layer Measurement - PoE Check
BER Measurement
QoS Test
Slide 14Slide 14Go to ...
Slide 27Slide 27Go to ...
Slide 30Slide 30Go to ...
Slide 31Slide 31Go to ...
Slide 33Slide 33Go to ...
IP Network Measurement Division14
4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink TestLink test at Link Up/Down
Link flap
DUT
Link up
Link down
Link up(On)
Link down(Off)
Loop count
Link checkerThe MD1230B can use the monitoring link status and displays link errors.
MU120131A/32AMU120131A/32A
7
IP Network Measurement Division15
4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink TestThe Link Up/Down test is performed at the Physical I/F screen.
MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A
MU120121A Screen
MU120131A Screen
Switch Link Up/Down manually, and confirm the DUT behavior.
*The Link Up/Down test and the Link Flap test can be done at the MU120131/32A.
Confirm that the link is normal when Link Up/Down is repeated 100 times by using the Flap function at On/Off intervals of 10 s and 1 s, respectively.
*Manual can also be selected for Link Up/Down at the MU120121A.
IP Network Measurement Division16
4. Physical Layer Measurement 4. Physical Layer Measurement –– Link TestLink Test
Set “No/Go Check” to On, and start the test at “Flap Setting.”
OK Example
*The MD1230B displays OK at “Status:” when the Link is connected. It displays NG and stops the count when the Link is restored.
MU120131A/32AMU120131A/32A
NG Example
8
IP Network Measurement Division17
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation AnalysisAuto-Negotiation Analysis at MU120112A/22A/32A
Option-15Option-15
Auto-Negotiation AnalysisAuto-Negotiation Analysis Code Data TransmissionCode Data Transmission
Link Timer TestLink Timer Test
Port1
Port 1Through Mode
Port 1 Port 2
Port 2 Port 1
Confirming auto-negotiation sequenceConfirming interoperabilityTroubleshooting
Confirming auto-negotiation sequenceChecking illegal code reception
Confirming operation by changing auto-negotiation time
IP Network Measurement Division18
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation AnalysisClick “Setup Utility”at the Selector screen when performing Auto-Negotiation Analysis at MU120112A.
Setup Utility
Select the operation mode using the pull-down menu.
Open “Firmware Functionality” and select “Auto Negotiation” for the slot.Click the Apply button, exit the Setup Utility, and open the Main Application.
*This procedure is not necessary at MU120122A/32A.
Option-15Option-15
9
IP Network Measurement Division19
4. Link Test 4. Link Test –– Link Timer TestLink Timer TestConfirm the inter-operativity for the DUT Link Timer by changing the Link Timer value.
Right-click Port1(Unit1:5:1) at the MU120132A and select “Port Setting...”Check “Timeout Enable” at “Auto Negotiation.” Check “Change Link Timer:”and set the value to 0 to 100 ms.
*The link becomes enable/not enable as the Link Timer value is changed gradually between 0 and 100 ms. The standard is 10 to 20 ms.
IP Network Measurement Division20
Capture and Decode
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
List of captured data
Start/Stop
Shows decodeddata in these fields
Select capture port
Decodes captured auto-negotiation data Analyze both protocoland data levels on one screen to check inter-operability
10
IP Network Measurement Division21
Determines Negotiation States Automatically
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
Determines auto-negotiationstate for each device from captured dataMakes checking auto-negotiation function easy
DUT-ADUT-B
MD1230B
IP Network Measurement Division22
Trigger Setting Screen Filter
Efficient Troubleshooting
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
Captures auto-negotiation data only when changesTrigger and filter functions help select only important dataSolves auto-negotiation problems quickly and efficiently
11
IP Network Measurement Division23
Changing MII Registers During Capture
MII Registers
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
ChangeMII Registers
Data Capture
DUTMD1230B
Change MII Registersduring captureControl registers such asPHY Reset and RestartAuto-Negotiation withoutdisconnecting fibers
IP Network Measurement Division24
DUT-AMD1230B
Port1
Auto-Negotiation Sequence Generator
• Generate auto-negotiation code data• Create sequences of up to 256 patterns• Capture and analyze auto-negotiation data simultaneously• Perform abnormal data tests
• Generate auto-negotiation code data• Create sequences of up to 256 patterns• Capture and analyze auto-negotiation data simultaneously• Perform abnormal data tests
Transmitauto-negotiation data
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
12
IP Network Measurement Division25
Edit Auto-Negotiation Sequence Code Data
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
Transmitting On/Off
Choose transmitting pattern
Transmit up to 256 code data patternsSelect “Code Data” from pull-down menuin Send Data edit screenCreate code data sequences quickly andeasily
IP Network Measurement Division26
Example
4. Link Test 4. Link Test –– AutoAuto--Negotiation AnalysisNegotiation Analysis Option-15Option-15
DUT
Transmit code data
Capture and analyze code data
Transmit auto-negotiation test sequenceCheck response sequence
Transmit abnormal auto-negotiation sequenceCheck response under abnormal conditions
MD1230B
13
IP Network Measurement Division27
4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock Measurement
The Clock Measurement functionThe Clock Measurement function is used to confirm that the DUT clock is within ±100 ppm.The Clock Variation functionThe Clock Variation function is used to monitor the DUT behavior when the clock speed is changed.
DUT DUT
Tx
Rx
MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01
Manual Link Test–100 ppm OK?+100 ppm OK?
Manual Forwarding TestTx –100 ppm Rx –100 ppm OK?Tx +100 ppm Rx –100 ppm OK?Tx –100 ppm Rx +100 ppm OK?Tx +100 ppm Rx +100 ppm OK?
Link Test Frame Forwarding Test
IP Network Measurement Division28
4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock MeasurementClock Measurement is performed at the Physical I/F Screen.
MU120121A Screen
MU120131A Screen (with Opt. 01)
*The clock measurement function is added at the MU120121A/22A.
① Confirm the clock is within ±100 ppm.
①
①
Supports monitoring of clock counters for several ports.Supports monitoring log function.
MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01
14
IP Network Measurement Division29
4. Physical Layer Measurement 4. Physical Layer Measurement –– Clock MeasurementClock Measurement
② Changing the clock at the clock tolerance test confirms whether an error or link down occurs.
②
②*Two values can be set for one module at the MU120131/32A.Select clock 1 or 2 for Port 1-4, Port 5-8, and Port 9-12 at the MU120131A and for Port 1-4, and Port 5-8 at the MU120132A.
*The MU120121/22A “Clock Variation”function is moved to this screen.
MU120121A/22AMU120131A/32A-01MU120121A/22AMU120131A/32A-01
MU120121A Screen
MU120131A Screen (with Opt.01)
Clock Measurement is performed at the Physical I/F Screen.
IP Network Measurement Division30
4. Physical Layer Measurement 4. Physical Layer Measurement –– PoE CheckPoE CheckThe PoE check is performed at the MU120131A.
Checking PoE confirms the status of power from PoE ports.MU120131A-02MU120131A-02
MU120131A Screen (with Opt. 02)
0 to 30 V: Off (0 – 30 V)31 to 42 V: Under (31 – 42 V)43 V: Normal (43 V ~)
0 to 30 V: Off (0 – 30 V)31 to 42 V: Under (31 – 42 V)43 V: Normal (43 V ~)
15
IP Network Measurement Division31
5. BER Measurement 5. BER Measurement –– Packet BERPacket BER
Packet BER MeasurementThe Data field of the Ethernet frame at the Tx side is filled with a PRBS pattern and the BER is calculated at the Rx side.Bit error insertion
Preamble8 bytes
FCS4 bytes
DataSingle PRBS9
Cross PRBS23, 31
IFG12 bytesHeader
DUT
Rate/Programmable rate
Option-11Option-11
Error Insertion
IP Network Measurement Division32
5. BER Measurement 5. BER Measurement –– Error InsertionError InsertionBER is measured during error insertion at the Error Insertion Screen.
Set “Cross PRBS Error” for “Type.”Set “Programmed Rate” for “Timing,”and 1.0E-9 as “Programmed Rate.”Insert the error by clicking the [Error] button.
*Select the Line Error at this screen.
Option-11Option-11
16
IP Network Measurement Division33
6. QoS Measurement6. QoS Measurement
QoS Measurement
QoS TestChecking traffic priority control systemChecking quality of each client dataChecking total performance of network
QoS TestChecking traffic priority control systemChecking quality of each client dataChecking total performance of network
40 Mbit/s
QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut
20 Mbit/s
ID1: 10MID2: 10MID3: 10MID4: 10M
ID1:10MID2:5MID3:5MID4:0M
Priority Control
IP Network Measurement Division34
6. QoS Measurement 6. QoS Measurement –– Tx Stream Tx Stream –– Frame SettingFrame SettingCreate the stream by clicking “Add” at “Tx Stream.”
Edit the stream by clicking the “Edit...”button. Set “Frame Length” at “General”of “Frame Setting.”Check “VLAN,” and click the “Edit...”button. If “User priority” is too high, data may be discarded due to traffic overflow.
17
IP Network Measurement Division35
6. QoS Measurement 6. QoS Measurement –– Tx Stream Tx Stream –– Stream SettingStream SettingSelect “Continuous” at “Distribution:” of “Stream Control.”
Set "Inter Frame Gap:" to the value where traffic overflow occurs.
IP Network Measurement Division36
6. QoS Measurement 6. QoS Measurement –– CounterCounterClick the “Display Option” button, and set the counter display.
* The display items can be changed up/down.
*The default display is three settings.*The counter display can be either
Current or Accumulated or both Current and Accumulated.
Check the PoE Alarm at the PoE alarm count.E-PON frame errors can be counted by checking “Preamble CRC Error.”
18
IP Network Measurement Division37
6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter
40 Mbit/s
QoS ControlID1: 10 MbpsID2: Best EffortID3: Best EffortID4: 100% cut
20 Mbit/s
ID1: 10MID2: 10MID3: 10MID4: 10M
ID1:10MID2:5MID3:5MID4:0M
The Counter Screen include Multi-flow counter at the MU120131A/32A.
MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A
Flows: 256Flow Condition: Up to 4 IDs (16 bits x 4)Measurement: Transmit/Receive frames
Transmit/Receive bitsRateLatencySequence error
Priority Control
The main frame supports up to 256 flows in real time.Other flows are measured statistically.
IP Network Measurement Division38
6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A
40 Mbit/s
QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut 20 Mbit/s
ID1: 10MID2: 10MID3: 10MID4: 10M
ID1:10MID2:5MID3:5MID4:0M
Step 1Flow ID Setting
Priority Control
Step 1Flow ID Setting
Set IP address of ID1 to ID4 as Flow filtering ID
19
IP Network Measurement Division39
6. QoS Measurement 6. QoS Measurement –– MultiMulti--flow counterflow counter MU120121A/22AMU120131A/32AMU120121A/22AMU120131A/32A
40 Mbit/s
QoS ControlID1: 10M bpsID2: Best EffortID3: Best EffortID4: 100% cut 20 Mbit/s
ID1: 10MID2: 10MID3: 10MID4: 10M
ID1:10MID2:5MID3:5MID4:0M
Priority Control
Check throughput of each flow using table view.
Step 2Flow measurementStep 2Flow measurement
Check throughput of each flow using graph view.
Check latency of each flow.
ID1 >ID2 >ID3 >ID4 >
IP Network Measurement Division40
7. Setting Grouping7. Setting GroupingSetting the grouping supports transmitting/receiving between anycombination of multiple ports in the same way as the RFC2544 auto-test.
Measurement can be performed as Fully Meshed, Partially Meshed, or One to One.
Fully Meshed Partially Meshed One to One
*Can be used for checking all ports of DUT
*Can also be used for multiple measurements per port (multicast and PON measurement, etc.)
*Used for multiple simultaneous transmitting at one to one combination.
20
IP Network Measurement Division41
Other FunctionsOther Functions
Arrival Time Variation/Latency VariationProtocol Emulation, etc.
Ch2
Server (Encode) Client (Decode)
R
SW
Latency Variation
Latency histogram screen
Display variation in network latency as histogramChecking traffic fluctuationChecking fluctuation of filtered Flow/Service
IP Network Measurement Division42
Utility FunctionsUtility Functions
21
IP Network Measurement Division43
Report FunctionReport Function
New Pause function
HTML-format report file (displayed and printed at external PC)
*Supports Counter, Multi-flow counter, Latency, Capture, RFC2544, RFC2889 (Measurement results saved as graph with measurement conditions for later analysis)
*New Pause function assists results saving during measurement.
IP Network Measurement Division44
The configuration of the units controlled by this software and their functions are displayed at the Tree ViewTree View on the left of the screen.Unit and port settings and group input can be performed in the Tree ViewTree View.
Click the Tree View iconTree View icon or press the Tree View keyTree View keyon front panel to toggle the Tree View on and off.
Tree ViewTree View
22
IP Network Measurement Division45
(1) Save and Load Measurement Conditions and ResultsAfter stopping measurement, click the FD icon at the top of the window to save measurement conditions and results. This function cannot be used during measurement, transmission, counting capturing, etc.
(2) Save and load procedure
a. Stop all measurements.b. Select save/load target in
Tree View.c. Select “Save…” or “Load…”d. Select the destination.e. Select the item to save or load.f. Click Execute.
Save/load target;Unit: All modules, All portsModule: Port in selected modulePort: Selected port
An error will occur if the user does not select the same load target condition as the save target condition.
Save/load target;Unit: All modules, All portsModule: Port in selected modulePort: Selected port
An error will occur if the user does not select the same load target condition as the save target condition.
Save and LoadSave and Load
IP Network Measurement Division46
Save and Load Save and Load –– Speed UpSpeed Up
The speed of batch Save and Load for the Stream setting for all ports has been increased.
*A binary image transfer function has been added to the previous text file output. *This is useful for customers with multiple stream settings.
23
IP Network Measurement Division47
(1) PrintingClick the Printer icon at the top right of the window and select “Print… .”Next, select the print target and Click “Print.”Items that can be printed change according to the displayed screen.
Print and Screen CopyPrint and Screen Copy
(1)
File format: Bitmap or JPEG
Select the output destination.
(2)
(2) Screen CopyClick the Printer icon at the top right of the window and select “Screen Copy Setting.”Next, set the file destination and format.Press the Screen Copy key on the front panel to save the current screen.
IP Network Measurement Division48
EndEndThank you.Thank you.
24
Anritsu Corporation5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 JapanPhone: +81-46-223-1111Fax: +81-46-296-1264
• U.S.A.Anritsu Company1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A.Toll Free: 1-800-267-4878Phone: +1-972-644-1777Fax: +1-972-671-1877
• CanadaAnritsu Electronics Ltd.700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, CanadaPhone: +1-613-591-2003 Fax: +1-613-591-1006
• Brazil Anritsu Eletrônica Ltda.Praca Amadeu Amaral, 27 - 1 Andar01327-010-Paraiso-São Paulo-BrazilPhone: +55-11-3283-2511Fax: +55-11-3288-6940
• U.K.Anritsu EMEA Ltd.200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K.Phone: +44-1582-433200 Fax: +44-1582-731303
• FranceAnritsu S.A.9 Avenue du Québec, Z.A. de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1-60-92-15-50Fax: +33-1-64-46-10-65
• GermanyAnritsu GmbHNemetschek Haus, Konrad-Zuse-Platz 1 81829 München, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55
• ItalyAnritsu S.p.A.Via Elio Vittorini 129, 00144 Roma, ItalyPhone: +39-6-509-9711 Fax: +39-6-502-2425
• SwedenAnritsu ABBorgafjordsgatan 13, 164 40 KISTA, SwedenPhone: +46-8-534-707-00 Fax: +46-8-534-707-30
• FinlandAnritsu ABTeknobulevardi 3-5, FI-01530 VANTAA, FinlandPhone: +358-20-741-8100Fax: +358-20-741-8111
• DenmarkAnritsu A/SKirkebjerg Allé 90, DK-2605 Brøndby, DenmarkPhone: +45-72112200Fax: +45-72112210
• SpainAnritsu EMEA Ltd. Oficina de Representación en EspañaEdificio VeganovaAvda de la Vega, n˚ 1 (edf 8, pl 1, of 8)28108 ALCOBENDAS - Madrid, SpainPhone: +34-914905761Fax: +34-914905762
• United Arab EmiratesAnritsu EMEA Ltd.Dubai Liaison OfficeP O Box 500413 - Dubai Internet CityAl Thuraya Building, Tower 1, Suit 701, 7th FloorDubai, United Arab EmiratesPhone: +971-4-3670352Fax: +971-4-3688460
• SingaporeAnritsu Pte. Ltd.10, Hoe Chiang Road, #07-01/02, Keppel Towers,Singapore 089315 Phone: +65-6282-2400 Fax: +65-6282-2533
• IndiaAnritsu Pte. Ltd. India Branch OfficeUnit No. S-3, Second Floor, Esteem Red Cross Bhavan,No. 26, Race Course Road, Bangalore 560 001, IndiaPhone: +91-80-32944707Fax: +91-80-22356648
• P.R. China (Hong Kong)Anritsu Company Ltd.Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East,Kowloon, Hong KongPhone: +852-2301-4980Fax: +852-2301-3545
• P.R. China (Beijing)Anritsu Company Ltd.Beijing Representative OfficeRoom 1515, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 10004, P.R. ChinaPhone: +86-10-6590-9230Fax: +86-10-6590-9235
• KoreaAnritsu Corporation, Ltd.8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, KoreaPhone: +82-2-553-6603Fax: +82-2-553-6604
• AustraliaAnritsu Pty. Ltd.Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, AustraliaPhone: +61-3-9558-8177Fax: +61-3-9558-8255
• TaiwanAnritsu Company Inc.7F, No. 316, Sec. 1, Neihu Rd., Taipei 114, TaiwanPhone: +886-2-8751-1816Fax: +886-2-8751-1817
Specifications are subject to change without notice.
No.MD1230_MP1590-E-T-1-(1.00) Printed in Japan 2007-3 ADK
Please Contact:
070207
Printed on 70% Recycled Paper