Quick Installation Guide · IGS-6325-20T4C4X # configure terminal IGS-6325-20T4C4X (config) #...
Transcript of Quick Installation Guide · IGS-6325-20T4C4X # configure terminal IGS-6325-20T4C4X (config) #...
Industrial L3 20-Port 10/100/1000T +
4-Port Gigabit TP/SFP + 4-Port 10G SFP+
Managed Ethernet Switch
IGS-6325-20T4C4X
Quick Installation Guide
Table of Contents
1. Package Contents ....................................................................................... 3
2. Requirements ............................................................................................. 4
3. Wiring DC Power Inputs .............................................................................. 5
4. Terminal Setup ........................................................................................... 6
4.1. Logging on to Console ......................................................................... 7
4.2. ConfiguringIPAddressviaConsole ....................................................... 8
5. Starting Web Management .........................................................................10
5.1 LoggingintotheIndustrialManagedSwitch .........................................10
5.2. SavingConfigurationviaWeb ..............................................................13
6. RecoveringBacktoDefaultConfiguration .....................................................15
7. Customer Support .....................................................................................16
3
1. Package ContentsThank you for purchasing PLANET Industrial L3 Managed Ethernet Switch.“Industrial Managed Switch” is used as an alternative name in this QuickInstallationGuide.
Open the box of the Industrial Managed Switch and carefully unpack it. The boxshouldcontainthefollowingitems:
z TheIndustrialManagedSwitch x1
z QuickInstallationGuide x1
z DB9toRJ45InterfaceRS232ConsoleCable x1
z Rubber Feet x 4
z RackMountAccessoryKit x1
z ACPowerCord x1
z SFP Dust Cap x 8
z RJ45DustCap x25
If any item is found missing or damaged, please contact your local reseller forreplacement.
4
2. RequirementsThe Industrial Managed Switch provides remote login interface for managementpurposes.Thefollowingequipmentisnecessaryforfurthermanagement:
z Workstations runningWindows 10/XP/2003/Vista/7/8/2008, MAC OS X or later,Linux,UNIX,orotherplatformsarecompatiblewithTCP/IPProtocols.
z WorkstationsareinstalledwithEthernetNIC(NetworkInterfaceCard)
z SerialPortConnection(Terminal)
The above Workstations come with COM Port (DB9) or USB-to-RS232converter.
The aboveWorkstations have been installed with terminal emulator, such asHyperTerminalincludedinWindowsXP/2003,puttyorTeraTerm.
Serial cable -- one end is attached to theRS232 serial port,while the otherendtotheconsoleportoftheIndustrialManagedSwitch.
z EthernetPortConnection
Networkcables--Usestandardnetwork(UTP)cableswithRJ45connectors.
The above PC is installed with Web browser and JAVA runtime environmentplug-in.
Note
It is recommended touse InternetExplore8.0or above toaccessthe Industrial Managed Switch. If theWeb interface of the Indus-trialManagedSwitchisnotaccessible,pleaseturnofftheanti-virussoftwareorfirewallandthentryitagain.
5
3. Wiring DC Power InputsThe6-contact terminalblock connectoron thepanelof IndustrialManagedSwitchisusedfortwoDCredundantpowersinput.Pleasefollowthestepsbelowtoinsertthe power wires.
1.Insertpositive/negativeDCpowerwires intocontacts1and2forDCPOWER1,or5and6forDCPOWER2.
DI/DO
FaultR.O.
Ring
AC
DC 2
DC 1
42
31
100~240V AC
50/60 Hz
ON
AC
PO
WE
R
OFF
DC POWERON
OFFDC Input Range:
36V~60V Fault
GNDGNDDO 1DO 0DI 1DI 0
DC 2DC 1
Figure 3-1 6-contact terminal block connector
2.Tightenthewire-clampscrewsforpreventingthewiresfromloosening.
1 2 3 4 5 6Power 1 Fault Power 2+ - + -
Figure 3-2 The pin of 6-contact terminal block connector
Note
The wire gauge for the terminal block should be in the rangebetween12and24AWG.
6
4. Terminal SetupToconfigurethesystem,connectaserialcabletoaCOMportonaPCornotebookcomputerandtoRJ45typeofserialportoftheIndustrialManagedSwitch.
Managed Switch
PC / Workstationwith
Terminal Emulation Software
Serial Port
RS232 to RJ45 Cable
Console PortRJ45
Figure 4-1 Industrial Managed Switch Console Connectivity
A terminal program is required tomake the software connection to the IndustrialManagedSwitch.
1. Run terminal program on the OS.
2.When the following screen appears, make sure that the COM port should beconfiguredas:
Baud:115200
Databits:8
Parity:None
Stopbits:1
Flowcontrol:None
Figure 4-2 COM Port Configuration
7
4.1. Logging on to ConsoleOnce the terminal is connected to the device, power on the Industrial ManagedSwitchandtheterminalwilldisplay“runningtestingprocedures”.
Then, the followingmessage asks to log in user nameandpassword. The factorydefault user name and password are shown as follows and the login screen inFigure4-3appears.
Username:adminPassword:admin
Figure 4-3: Industrial Managed Switch Console Login Screen
Theusercannowentercommands tomanagetheIndustrialManagedSwitch.Foradetaileddescriptionofthecommands,pleaserefertothefollowingchapters.
Note
1.Forsecurity reason,pleasechangeandmemorize thenewpass-wordafterthisfirstsetup.
2.Only accept command in lowercase letter under console inter-face.
8
4.2.ConfiguringIPAddressviaConsoleTheIndustrialManagedSwitchisshippedwithdefaultIPaddressshownbelow.
IPAddress:192.168.0.100SubnetMask:255.255.255.0
TocheckthecurrentIPaddressormodifyanewIPaddressfortheSwitch,pleaseusetheproceduresasfollows:
ShowthecurrentIPAddress1.Atthe“#”prompt,enter“show ip interface brief”.
IGS-6325-20T4C4X#show ip interface brief
2.ThescreendisplaysthecurrentIPaddressasshowninFigure4-4.
Figure 4-4: IP Information Screen
ConfiguringIPAddress3.At the “#”prompt,enter the followingcommandandpress<Enter> as shown inFigure4-5.
IGS-6325-20T4C4X#configure terminalIGS-6325-20T4C4X(config)#interface vlan 1IGS-6325-20T4C4X(config-if-vlan)#ip address 192.168.1.100 255.255.255.0
The previous command would apply the following settings for the IndustrialManagedSwitch.
IPAddress:192.168.1.100SubnetMask:255.255.255.0
Figure 4-5: Configuring IP Address Screen
9
4.Repeatstep1tocheckiftheIPaddressischanged.
Storecurrentswitchconfiguration5.Enterthefollowingcommandandpress<Enter>togobackto“#”prompt.
# exit
Figure 4-6: Inputting Exit Command Screen
6.Atthe“#”prompt,enterthefollowingcommandandpress<Enter>.
# copy running-config startup-config
Figure 4-7: Saving Current Configuration Command Screen
If the IP is successfully configured, the Industrial Managed Switch will apply thenew IP address setting immediately. You can access the Web interface of theIndustrialManagedSwitchthroughthenewIPaddress.
Note
If you are not familiar with the console command or the relatedparameter,enter“help”anytimeinconsoletogetthehelpdescrip-tion.
10
5. Starting Web ManagementThe following shows how to start up the Web Management of the IndustrialManaged Switch. Note the Industrial Managed Switch is configured through anEthernet connection. Pleasemake sure themanager PCmust be set to the sameIP subnet address.
For example, the default IP address of the Industrial Managed Switch is192.168.0.100, then the manager PC should be set to 192.168.0.x (where xis a number between 1 and 254, except 100), and the default subnet mask is255.255.255.0.
PC / Workstationwith Web Browser
192.168.0.x
Managed Switch
RJ45/UTP Cable
IP Address:192.168.0.100
Figure 5-1: IP Management Diagram
5.1 Logging in to the Industrial Managed Switch1.Use Internet Explorer 8.0 or above Web browser and enter IP address
http://192.168.0.100(thefactorydefaultIPaddressortheonethatyouhavejustchangedinconsole)toaccesstheWebinterface.
2.When the followingdialogboxappears,pleaseenter thedefaultusernameandpassword“admin” (or the password youhave changed via console). The loginscreeninFigure5-2appears.
11
DefaultUsername:adminDefaultPassword:admin
Figure 5-2: Login Screen
3.Afterenteringthepassword,themainscreenappearsasFigure5-3shows.
Figure 5-3: Web Main Screen of Industrial Managed Switch
12
The Switch Main Menu is shown on top of the Web page, and the functions areshownonthelefttoconfiguretheIndustrialManagedSwitch.
Figure 5-4: Switch Menu
Now, you can use the Web management interface to continue the SwitchmanagementormanagetheSwitchbyconsole interface.Pleaserefertotheuser’smanualformore.
Note
Ifyouarenot familiarwithSwitch functionsor the relatedparam-eter, press “Help icon” anytime on theWeb page to get the helpdescription.
13
5.2.SavingConfigurationviaWebIn the IndustrialManagedSwitch, the running configuration stores in theRAM. Inthecurrentversion, therunningconfigurationsequenceofrunning-config can be savedfromtheRAMtoFLASHbyexecutingsavestartupconfigcommand,sothattherunningconfigurationsequencebecomesthestartupconfigurationfile,whichiscalledconfigurationsave.
To save all applied changes and set the current configuration as a startupconfiguration, the startup-configuration file will be loaded automatically across asystem reboot.
1. Click Maintenance > Switch Maintenance > Save Startup Config.
Figure 5-5: Maintenance
Figure 5-6: Save Startup Config
14
2. Or you can press the “Save Configuration” button.
Figure 5-7: Save Configuration Button
3. Press the “Save Configuration”buttontosave.
Figure 5-8: Save Configuration
15
6.RecoveringBacktoDefaultConfiguration IP address has been changed or admin password has been
forgotten – To reset the IP address to the default IP address “192.168.0.100” or reset the login password to default value, press the hardware reset button on the rear panel for about 10 seconds. After the device is rebooted, you can log in themanagementWebinterfacewithinthesamesubnetof192.168.0.xx.
22 24 2826
Console
Reset115200, N, 8, 1
IGS-6325-20T4C4X
21 22 23 24 27 2825 26
100010/100
100010G
Figure 6-1: IGS-6325-20T4C4X Reset Button
16
7. Customer SupportThank you for purchasing PLANET products. You can browse our online FAQresourceandUser’sManualonPLANETWebsitefirsttocheckifitcouldsolveyourissue.Ifyouneedmoresupportinformation,pleasecontactPLANETswitchsupportteam.
PLANETonlineFAQs:http://www.planet.com.tw/en/support/faq?method=category&c1=3
Switchsupportteammailaddress:[email protected]
IGS-6325-20T4C4XUser’sManual:https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=IGS-6325&view=3#list
(Pleaseselectthesuitableuser’smanualfromthelist.)
Copyright © PLANET Technology Corp. 2018.Contents are subject to revision without prior notice.PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.