QUICK COUPLINGS - tst-tamsan.com · meet- en regelsystemen: • Installatiebouw • Medische...
Transcript of QUICK COUPLINGS - tst-tamsan.com · meet- en regelsystemen: • Installatiebouw • Medische...
QUICK COUPLINGS
SWING COUPLING / SV SERIE / STAINLESS STEEL SERIE
www.tst-tamsan.com
67tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
Product Overview
DN11SV 1-Stage
Non-interchangeableHeavy-Duty Range
DN31/8˝
SV 1-Stagewith metal release ring
DN111/2˝
DN83/8˝
DN61/4˝
SV 2-Stage
with metal release ring
DN193/4˝
DN111/2˝
SV 2-StageHeavy-Duty Range
DN61/4˝
SV 2-Stage Non-Interchangeable
Stainless Steel Series
68 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 1-Stage
DN3Auf einen Blick
Einfache Bedienung – geringer Kraftaufwand
Kompakte Bauform
Hohe Standzeit – wartungsarm
Sterilisierbar (CIP)
AnwendungsbereichDruckluft- und Gasversorgung, Mess-, Steuer- und Regeltechnik, Automation in:• Anlagenbau• Medizinaltechnik, Chemie und Pharma
HandhabungEinkuppelnStecknippel in Kupplung eindrücken bis er hörbar einrastet.
AuskuppelnAuslösering nach links drehen undStecknippel herausziehen.
Um ein gefährliches Rückschlagen zu vermeiden, muss der Stecknippel so lange in der Hand gehalten werden, bis der Schlauch vollständig entlüftet ist.
En brefManiement simple et sans effort
Forme compacte
Durée de vie élevée – entretien minime
Stérilisable (CIP)
Domaine d’applicationAlimentation en gaz et en air comprim, équipement de mesure, de pilotage, de réglage et d’automatisme par ex.:• moyens de production• technique médicale, chimie et pharmacie
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur jusqu’au déclic audible.
DésaccouplementTourner la bague de déclenchement vers la gauche et puis désengager l’about de raccordement.
Pour éviter un coup de fouet du tuyau,il convient de garder l’about en mainjusqu’à ce que le tuyau soit entièrement purgé.
FeaturesSimple operation – minimal connection force needed
Compact design
Long service life – low maintenance
Sterilizable (CIP)
ApplicationCompressed air and gas supply, measurement and control systems in:• Machine and apparatus engineering• Medical, chemical and pharmaceutical
ProcedureConnectionPush plug into coupling until it is heard to engage by a click.
DisconnectionTurn release ring to the left and pull out plug.
In order to prevent the hose from ejecting dangerously, the plug must be held in the hand until the hose is completely ventilated.
In een oogopslagEenvoudig en zonder moeite te bedienen
Compact ontwerp
Duurzaam – onderhoudsarm
Steriliseerbaar (CIP)
ToepassingsgebiedPerslucht- en gasvoorzieningen, meet- en regelsystemen:• Installatiebouw• Medische techniek, chemie en farmacie
GebruikKoppelenDruk de insteeknippel in de koppeling totdat er hoorbaar een verbinding wordt gemaakt.
OntkoppelenDraai de ontkoppelingsring naar links en trek de insteeknippel los.
Om een gevaarlijke loskoppeling van de slang te voorkomen, moet deinsteeknippel met de hand vast worden gehouden totdat de slang volledig is ontlucht.
ISO 6150-C
Plug Profile Compatible withTST 107.03
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
1/8˝
STEEL
21.511.6
7.2
Ø5
Ø7.
4
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
69tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
SV 1 - Stage
DN3
with male thread
with hose tail Steel303 00 585303 00 586303 00 587
D4 mm 3/16˝6 mm 1/4˝8 mm 5/16˝
Steel355 00 276355 00 277
D4 mm 3/16˝6 mm 1/4˝
with female thread
with male thread
with female thread
with hose tail
A SteelG1/8NPT1/8
303 00 580303 00 581
A SteelG1/8NPT1/8G1/4
303 00 582303 00 584303 00 583
QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
PLUG STECKNIPPEL
A SteelG1/8NPT1/8
355 00 274355 00 338
A SteelG1/8NPT1/8
355 00 273355 00 339
39.7
Ø17 A
Ø17
32.7
A
45.7
Ø17 D
A
29
SW14
A
36.5
SW14
D
39.5
Ø10
1/8˝
70 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
DN6 ISO 6150-C-10
Compatible withTST 107.06Swing Coupling Serie K
1/4˝Auf einen Blick
2-Stufen-Entkupplung
Einfache Bedienung – geringer Kraftaufwand
Hohe Standzeit – wartungsarm
Sterilisierbar (CIP)
AnwendungsbereichDruckluft- und Gasversorgung, Mess-, Steuer- und Regeltechnik in:• Anlagenbau• Medizinaltechnik, Chemie und Pharma• Nahrungsmittel- und Getränkeindustrie
HandhabungEinkuppelnStecknippel in Kupplung eindrücken bis er hörbar einrastet.
AuskuppelnDurch Linksdrehung des Auslöseringswird der Stecknippel ausgekuppelt,jedoch von der Sicherheitsklinke zurückgehalten, bis der Schlauch entlüftet ist. Erst nach Rechtsdrehung des Auslöserings wird der Stecknippel freigegeben.
En brefDésaccouplement en 2 temps Forme compacte
Maniement simple et sans effort
Durée de vie élevée – entretien minime
Stérilisable (CIP)
Domaine d’applicationAlimentation en gaz et en air comprimé, équipement de mesure, de pilotage, de réglage et d’automatisme par ex.:• moyens de production• technique médicale, chimie et pharmacie• Industrie alimentaire et des boissons
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur jusqu’au déclic audible.
DésaccouplementUn mouvement à gauche de la bague de déclenchement dégage l’about de raccordement retenu par le cliquet de sécurité jusqu’à ce que le tuyau soit purgé. En tournant la bague dedéclenchement vers la droitel’about de raccordement sera entièrement dégagé.
Features2-stage disconnection
Simple operation – minimal connectionforce needed
Long service life – low maintenance
Sterilizable (CIP)
ApplicationCompressed air and gas supply, measurement and control systems in:• Machine and apparatus engineering• Medical, chemical and pharmaceutical• Food- and beverage industry
ProcedureConnectionPush plug into coupling until it is heard to engage by a click.
DisconnectionThe plug is disconnected by turning the release ring to the left. It is held back by the safety catch, until the hose is ventilated. The plug can only be released by turning the release ring to the right.
2-staps ontkoppeling
Eenvoudig en zonder moeite te bedienen
Duurzaam - onderhoudsarm
Steriliseerbaar (CIP)
ToepassingsgebiedPerslucht- en gasvoorzieningen, meet- en regelsystemen:• Installatiebouw• Medische techniek, chemie en farmacie• Voedsel- en drankenindustrie
GebruikKoppelenDruk de insteeknippel in de koppelingtotdat er hoorbaar een verbinding wordtgemaakt.
OntkoppelenDe insteeknippel kan wordenlosgekoppeld door de ontkoppelingsring naar links te draaien. De insteeknippel wordt door de borggrendel tegengehouden, totdat de slang is ontlucht. De insteeknippel kan alleen worden ontkoppeld door de ontkoppelingsring naar rechts te raaien.
In een oogopslag
SV 2-Stage
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
Plug Profile K
Ø 9
.8Ø
7.5
9.312
26
71tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
SV 2 - Stage
DN6QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
Steel303 00 595303 00 596303 00 597
D6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝ 303 00 598
with hose tailwith male threadwith female thread
A SteelG1/8G1/4NPT1/4G3/8NPT3/8G1/2
303 00 588303 00 589303 00 599303 00 590303 00 600303 00 591
Steel355 00 102355 00 103355 00 104
D6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝ 355 00 105
with hose tail
PLUG STECKNIPPEL
A SteelG1/8G1/4NPT1/4G3/8NPT3/8
355 00 125355 00 126355 00 129355 00 127355 00 130
with male thread
Steel353 00 121353 00 122353 00 123353 00 313
D6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝
with hose tail
D
85
SW17
A SteelG1/4NPT1/4G3/8NPT3/8
353 00 119353 00 311353 00 120353 00 312
with male thread
A
64
SW19
with female thread
A SteelG1/4NPT1/4G3/8NPT3/8
353 00 117353 00 309353 00 118353 00 310
PLUG WITH CHECK VALVE VERSCHLUSSNIPPEL
A
75
SW19
A SteelG1/8G1/4NPT1/4NPT3/8
355 00 123355 00 124355 00 208355 00 264
with female thread
1/4˝
Ø24
62.5
A
A SteelG1/4NPT1/4G3/8NPT3/8G1/2
303 00 592303 00 601303 00 593303 00 602303 00 594
Ø24
48.7
A
Ø24
82
D
D
58
Ø16A
55
SW17
A
38.7
SW17
72 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
DN8 ISO 6150-C-14
Compatible withTST 107.08Swing Coupling Serie E1
3/8˝Auf einen Blick
2-Stufen-Entkupplung
Einfache Bedienung – geringer Kraftaufwand
Hohe Standzeit – wartungsarm
Sterilisierbar (CIP)
AnwendungsbereichDruckluft- und Gasversorgung, Mess-, Steuer- und Regeltechnik in:• Anlagenbau• Medizinaltechnik, Chemie und Pharma• Nahrungsmittel- und Getränkeindustrie
HandhabungEinkuppelnStecknippel in Kupplung eindrücken bis er hörbar einrastet.
AuskuppelnDurch Linksdrehung des Auslöseringswird der Stecknippel ausgekuppelt,jedoch von der Sicherheitsklinke zurückgehalten, bis der Schlauch entlüftet ist. Erst nach Rechtsdrehung des Auslöserings wird der Stecknippel freigegeben.
Désaccouplement en 2 temps Forme compacte
Maniement simple et sans effort
Durée de vie élevée – entretien minime
Stérilisable (CIP)
Domaine d’applicationAlimentation en gaz et en air comprimé, équipement de mesure, de pilotage, de réglage et d’automatisme par ex.:• Moyens de production• Technique médicale, chimie et pharmacie• Industrie alimentaire et des boissons
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur jusqu’au déclic audible.
DésaccouplementUn mouvement à gauche de la bague de déclenchement dégage l’about de raccordement retenu par le cliquet de sécurité jusqu’à ce que le tuyau soit purgé. En tournant la bague dedéclenchement vers la droitel’about de raccordement sera entièrement dégagé.
Features2-stage disconnection
Simple operation – minimal connectionforce needed
Long service life – low maintenance
Sterilizable (CIP)
ApplicationCompressed air and gas supply, measurement and control systems in:• Machine and apparatus engineering• Medical, chemical and pharmaceutical• Food- and beverage industry
ProcedureConnectionPush plug into coupling until it is heard to engage by a click.
DisconnectionThe plug is disconnected by turning the release ring to the left. It is held back by the safety catch, until the hose is ventilated. The plug can only be released by turning the release ring to the right.
In een oogopslag2-staps ontkoppeling
Eenvoudig en zonder moeite te bedienen
Duurzaam - onderhoudsarm
Steriliseerbaar (CIP)
ToepassingsgebiedPerslucht- en gasvoorzieningen, meet- en regelsystemen:• Installatiebouw• Medische techniek, chemie en farmacie• Voedsel- en drankenindustrie
GebruikKoppelenDruk de insteeknippel in de koppelingtotdat er hoorbaar een verbinding wordtgemaakt.
OntkoppelenDe insteeknip p el kan wordenlosgekoppeld door deontkoppelingsring naar links te draaien.De insteeknippel wordt door deborggrendel tegengehouden, totdat deslang is ontlucht. De insteeknippel kanalleen worden ontkoppeld door deontkoppelingsring naar rechts te raaien.
SV 2-Stage
En bref
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
Plug Profile E1
Ø11
Ø13
.8
13
17
36.5
73tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
SV 2 - Stage
DN83/8˝QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
Steel303 00 611303 00 612303 00 613
D8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝16 mm 5/8˝ 303 00 614
with hose tailwith male threadwith female thread
A SteelG1/4G3/8NPT3/8G1/2NPT1/2
303 00 300303 00 603303 00 605303 00 604303 00 606
Steel355 00 096355 00 097355 00 098
D8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝16 mm 5/8˝ 355 00 099
with hose tail
PLUG STECKNIPPEL
A SteelG1/4NPT1/4G3/8NPT3/8
355 00 090355 00 092355 00 091355 00 093
with male thread
Steel353 00 104353 00 106
D10 mm 3/8˝13 mm 1/2˝
with hose tail
A SteelG3/8NPT3/8
353 00 102353 00 315
with male threadwith female thread
A SteelG3/8NPT3/8
353 00 100353 00 314
PLUG WITH CHECK VALVE VERSCHLUSSNIPPEL
A Steel355 00 088355 00 094355 00 089355 00 095355 00 359
with female thread
A SteelG3/8NPT3/8G1/2NPT1/2
303 00 607303 00 609303 00 608303 00 610
G1/4NPT1/4G3/8NPT3/8NPT1/2
Ø30
85.6
A
67.6
Ø30 A
90.6
D
Ø30
D
63
Ø22
SW24
A
61.5
SW19A
44.7
A
79
Ø23 A
64.5
Ø22 D
90.5
Ø22
74 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
DN11 ISO 6150-C-14
Compatible withTST 107.11Swing Coupling Serie G
1/2˝Auf einen Blick
2-Stufen-Entkupplung
Einfache Bedienung – geringer Kraftaufwand
Hohe Standzeit – wartungsarm
Sterilisierbar (CIP)
AnwendungsbereichDruckluft- und Gasversorgung, Mess-, Steuer- und Regeltechnik in:• Anlagenbau• Medizinaltechnik, Chemie und Pharma• Nahrungsmittel- und Getränkeindustrie
HandhabungEinkuppelnStecknippel in Kupplung eindrücken bis er hörbar einrastet.
AuskuppelnDurch Linksdrehung des Auslöseringswird der Stecknippel ausgekuppelt,jedoch von der Sicherheitsklinke zurückgehalten, bis der Schlauch entlüftet ist. Erst nach Rechtsdrehung des Auslöserings wird der Stecknippel freigegeben.
En brefDésaccouplement en 2 temps Forme compacte
Maniement simple et sans effort
Durée de vie élevée – entretien minime
Stérilisable (CIP)
Domaine d’applicationAlimentation en gaz et en air comprimé, équipement de mesure, de pilotage, de réglage et d’automatisme par ex.:• moyens de production• technique médicale, chimie et pharmacie• Industrie alimentaire et des boissons
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur jusqu’au déclic audible.
DésaccouplementUn mouvement à gauche de la bague de déclenchement dégage l’about de raccordement retenu par le cliquet de sécurité jusqu’à ce que le tuyau soit purgé. En tournant la bague dedéclenchement vers la droitel’about de raccordement sera entièrement dégagé.
Features2-stage disconnection
Simple operation – minimal connectionforce needed
Long service life – low maintenance
Sterilizable (CIP)
ApplicationCompressed air and gas supply, measurement and control systems in:• Machine and apparatus engineering• Medical, chemical and pharmaceutical• Food- and beverage industry
ProcedureConnectionPush plug into coupling until it is heard to engage by a click.
DisconnectionThe plug is disconnected by turning the release ring to the left. It is held back by the safety catch, until the hose is ventilated. The plug can only be released by turning the release ring to the right.
In een oogopslag2-staps ontkoppeling
Eenvoudig en zonder moeite te bedienen
Duurzaam - onderhoudsarm
Steriliseerbaar (CIP)
ToepassingsgebiedPerslucht- en gasvoorzieningen, meet- en regelsystemen:• Installatiebouw• Medische techniek, chemie en farmacie• Voedsel- en drankenindustrie
GebruikKoppelenDruk de insteeknippel in de koppelingtotdat er hoorbaar een verbinding wordtgemaakt.
OntkoppelenDe insteeknippel kan wordenlosgekoppeld door deontkoppelingsring naar links te draaien.De insteeknippel wordt door deborggrendel tegengehouden, totdat deslang is ontlucht. De insteeknippel kanalleen worden ontkoppeld door deontkoppelingsring naar rechts te raaien.
SV 2-Stage
In een oogopslag
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
Plug Profile G
Ø11
Ø13
.8
13.618
41
75tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
SV 2 - Stage
DN111/2˝QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
Steel303 00 628303 00 154303 00 156
D13 mm 1/2˝16 mm 5/8˝19 mm 3/4˝
with hose tailwith male threadwith female thread
A SteelG3/8NPT3/8G1/2NPT1/2G3/4NPT3/4
303 00 615303 00 618303 00 616303 00 619303 00 617303 00 620
Steel355 00 119355 00 120355 00 121
D10 mm 3/8˝13 mm 1/2˝16 mm 5/8˝19 mm 3/4˝ 355 00 122
with hose tail
PLUG STECKNIPPEL
with male thread
Steel353 00 324353 00 147353 00 222
D13 mm 1/2˝16 mm 5/8˝19 mm 3/4˝
with hose tailwith male threadwith female thread
A Steel
PLUG WITH CHECK VALVE VERSCHLUSSNIPPEL
A Steel355 00 107355 00 113355 00 108355 00 114355 00 109355 00 115
with female thread
A SteelG3/8NPT3/8G1/2NPT1/2G3/4NPT3/4G1
303 00 621303 00 625303 00 622303 00 626303 00 623303 00 627303 00 624
G3/8NPT3/8G1/2NPT1/2G3/4NPT 3/4
A Steel355 00 110355 00 111355 00 117355 00 112355 00 118
G3/8G1/2NPT1/2G3/4NPT3/4
355 00 316355 00 318355 00 317355 00 319
G3/8NPT3/8G1/2NPT1/2
A Steel355 00 320355 00 322355 00 268355 00 323355 00 321
G3/8NPT3/8G1/2NPT1/2G3/4
Ø38
79.9
A
70.9
A
Ø38
Ø38
107.9
D
D
66
Ø22SW
32A
69
SW27
A
51
A
78
Ø30
114
D Ø30
92
A Ø30
76 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
DN11Heavy-Duty Range1/2˝Auf einen Blick
2-Stufen-Entkupplung
Extrem robuste Ausführung
Hohe Standzeit – wartungsarm
AnwendungsbereichDruckluft und Gasversorgung in extremrauen Bedingungen in:• Marine und Schiffsbau• Raffinerien (Öl- und Gasindustrie)
HandhabungEinkuppelnStecknippel in Kupplung einführen, nach rechts drehen bis der Mechanismus hörbar einrastet.
AuskuppelnStecknippel nach links drehen und gleichzeitig Auslösering leicht nach hinten ziehen. Der Stecknippel wird beim Ausstoss von der Sicherheitskammer aufgefangen und erst nach einer weiteren Links- oder Rechtsdrehung um 90° freigegeben.
En brefDésaccouplement en 2 temps Forme compacte
Modèle extrêmement robuste Durée de vie élevée – entretien minime
Domaine d’applicationAlimentation en gaz et en air comprimépour des conditions extrêmement rudes,par ex.:• Marine et construction navale• Raffineries (industrie du pétrole et du gaz)
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur et le tourner vers la droite jusqu’au déclic audible du mécanisme.
DésaccouplementTourner l’about de raccordement vers lagauche et en même temps tirer la bague de déclenchement légèrement vers l’arrière. L’about de raccordement est toutefois retenu dans la chambre de sécurité et seulement libéré après une rotation de 90° vers la gauche ou vers la droite.
Features2-stage disconnection
Extremely robust design
Long service life – low maintenance
ApplicationCompressed air and gas supply in extremely rough working conditions in:• Marine and ship-building• Petrochemical (oil and gas industries)
ProcedureConnectionPush plug into coupling and turn it to the right until the mechanism is heard to engage by a click.
DisconnectionTurn plug to the left while simultaneously gently pulling back the release ring. The plug is withheld from ejecting by the safety chamber and can only be released by another 90º turn to the left or to the right.
In een oogopslag2-staps ontkoppeling
Zeer robuust ontwerp
Duurzaam - onderhoudsarm
ToepassingsgebiedPerslucht- en gasvoorzieningen, bij extreme werkomstandigheden:• Marine en scheepsbouw• Raffinaderijen (olie- en gasindustrie)
GebruikKoppelenDuw de insteeknippel in de koppeling en draai deze naar rechts, totdat er hoorbaar een verbinding wordt gemaakt.
OntkoppelenDe insteeknippel kan wordenontkoppeld door de ontkoppelingsringnaar links te draaien. Het wordt doorde borgkamer tegengehouden en kanalleen worden ontkoppeld door denogmaals 90 graden naar links- ofrechts te draaien.
Features
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
Valved Plug
Unvalved Plug
77tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
DN11SV 2 - Stage
1/2˝QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
with female thread
A SteelG3/8NPT3/8G1/2NPT1/2G3/4NPT3/4
303 00 629303 00 631303 00 206303 00 632303 00 630303 00 633
Steel355 00 131355 00 132355 00 133
D10 mm 3/8˝13 mm 1/2˝16 mm 5/8˝19 mm 3/4˝ 355 00 134
PLUG STECKNIPPEL
with male thread
Steel353 00 332353 00 333353 00 273
D13 mm 1/2˝16 mm 5/8˝19 mm 3/4˝
with hose tailwith male threadwith female thread
A Steel
PLUG WITH CHECK VALVE VERSCHLUSSNIPPEL
A Steel355 00 135355 00 136355 00 285355 00 137355 00 340
G1/8G1/2NPT1/2G3/4NPT3/4
353 00 226353 00 325353 00 015353 00 326
G3/8NPT3/8G1/2NPT1/2
A Steel353 00 327353 00 330353 00 328353 00 331353 00 329
G3/8NPT3/8G1/2NPT1/2G3/4
with male thread
A SteelG3/8NPT3/8G1/2NPT1/2G3/4NPT3/4G1
303 00 634303 00 638303 00 635303 00 639303 00 636303 00 640303 00 637
with hose tail
Ø50
67.5
A
Ø50
76.5
A
A
54
SW27
83
D Ø22
D
114
Ø30A
78
Ø30A
92
Ø30
78 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
DN19Heavy-Duty Range3/4˝Auf einen Blick
2-Stufen-Entkupplung
Extrem robuste Ausführung
Hohe Standzeit – wartungsarm
AnwendungsbereichDruckluft und Gasversorgung in extrem rauen Bedingungen in:• Marine und Schiffsbau• Raffinerien (Öl- und Gasindustrie)
HandhabungEinkuppelnStecknippel in Kupplung einführen, nach rechts drehen bis der Mechanismus hörbar einrastet.
AuskuppelnStecknippel nach links drehen und gleichzeitig Auslösering leicht nach hinten ziehen. Der Stecknippel wird beim Ausstoss von der Sicherheitskammer aufgefangen und erst nach einer weiteren Links- oder Rechtsdrehung um 90° freigegeben.
En brefDésaccouplement en 2 temps Forme compacte
Modèle extrêmement robuste Durée de vie élevée – entretien minime
Domaine d’applicationAlimentation en gaz et en air comprimépour des conditions extrêmement rudes, par ex.:• Marine et construction navale• Raffineries (industrie du pétrole et du gaz)
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur et le tourner vers la droite jusqu’au déclic audible du mécanisme.
DésaccouplementTourner l’about de raccordement vers lagauche et en même temps tirer la bague de déclenchement légèrement vers l’arrière. L’about de raccordement est toutefois retenu dans la chambre de sécurité et seulement libéré après une rotation de 90° vers la gauche ou vers la droite.
2-staps ontkoppeling
Zeer robuust ontwerp
Duurzaam - onderhoudsarm
Features2-stage disconnection
Extremely robust design
Long service life – low maintenance
ApplicationCompressed air and gas supply in extremely rough working conditions in:• Marine and ship-building• Petrochemical (oil and gas industries)
ProcedureConnectionPush plug into coupling and turn it to the right until the mechanism is heard to engage by a click.
DisconnectionTurn plug to the left while simultaneously gently pulling back the release ring. The plug is withheld from ejecting by the safety chamber and can only be released by another 90º turn to the left or to the right.
In een oogopslag
ToepassingsgebiedPerslucht- en gasvoorzieningen, bij extreme werkomstandigheden:• Marine en scheepsbouw• Raffinaderijen (olie- en gasindustrie)
GebruikKoppelenDuw de insteeknippel in dekoppeling en draai deze naarrechts, totdat het mechanismehoorbaar een verbinding maakt.
OntkoppelenDe insteeknippel kan wordenontkoppeld door de ontkoppelingsringnaar links te draaien. Het wordt doorde borgkamer tegengehouden en kanalleen worden ontkoppeld door denogmaals 90 graden naar links- ofrechts te draaien.
Features
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
Valved Plug
Unvalved Plug
79tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
DN19SV 2 - Stage
3/4˝
Steel355 00 281355 00 282
D19 mm 3/4˝25 mm 1˝
PLUG STECKNIPPEL
with male thread
A Steel355 00 279355 00 341355 00 280355 00 342
G3/4NPT3/4G1NPT1
with hose tail
QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
with female thread
A SteelG3/4NPT3/4G1NPT1
303 00 641303 00 643303 00 642303 00 644
PLUG WITH CHECK VALVE VERSCHLUSSNIPPEL
Steel353 00 219353 00 218
D19 mm 3/4˝25 mm 1˝
with hose tail
Ø60
102.9
A
D
225
SW41
D
120
Ø32A
84
SW36
80 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 2-Stage
Auf einen Blick Verwechslung verschiedener Medienausgeschlossen, da nur mit Stecknippel mit gleichem Schlüssel zu betätigen
2-Stufen Entkupplung
Einsatz bei Verwechslungsgefahr
AnwendungsbereichFür sicherheitsrelevante Anwendungen,toxische Medien in:• Anlagenbau• Medizinaltechnik, Chemie und Pharma
HandhabungEinkuppelnStecknippel mit gleichem geometrischemSchlüssel in entsprechende Kupplung eindrücken bis er hörbar einrastet.
AuskuppelnDurch Linksdrehung des Auslöserings wird der Stecknippel ausgekuppelt, jedoch von der Sicherheitsklinke zurückgehalten bis der Schlauch entlüftet ist. Erst nach Rechtsdrehung des Auslöserings wird der Stecknippel freigegeben.
En brefInterversion de différents fluides impossible grâce à un profil de clé identique ducoupleur et de son about.
Désaccouplement en 2 temps Forme compacte
Application en cas de risque d’interversion
Domaine d’applicationPour les applications liées à la sécurité, les fluides toxiques, par ex.:• construction d’installations• technique médicale, chimie et pharmacie
ManipulationAccouplementIntroduire l’about de raccordement dontla clé est identique à celle du coupleur jusqu’au déclic audible.
DésaccouplementUn mouvement à gauche de la bague de déclenchement dégage l’about de raccordement qui cependant restera retenu par le cliquet de sécurité jusqu’à ce que le tuyau soit purgé. Ce n’est qu’en tournant la bague de déclenchement vers la droite que l’about de raccordement sera entièrement dégagé.
FeaturesMixing of different media isimpossible, as connection is only possible with plugwith identical key profile
2-stage disconnection
Eliminates danger of wrongline connection
ApplicationFor safety-related applications, toxic media in:• Machine and apparatus engineering• Medical, chemical and pharmaceutical
ProcedureConnectionPush plug into coupling with matching key profile until it is heard to engage by a click.
DisconnectionThe plug is disconnected by turning the release ring to the left. It is held back by the safety clutch, until the hose is ventilated. The plug can only be released by turning the release ring to the right.
Het samenkomen van vloeistoffen is uitgesloten, doordat er alleen verbinding kan worden gemaakt via een plug met een identiek sleutelprofiel
2-staps ontkoppeling
Voorkomt verbinding met onjuiste lijn
ToepassingsgebiedVeiligheidsgerelateerde toepassingen, giftige vloeistoffen:• Installatiebouw• Medische techniek, chemie, farmacie
GebruikKoppelenDruk de insteeknippel in de koppelingmet het juiste sleutelprofiel, totdat erhoorbaar een verbinding wordtgemaakt.
OntkoppelenDe insteeknippel kan wordenontkoppeld door de ontkoppelingsringnaar links te draaien. Deze wordt door de borggrendel tegengehouden, totdat de slang is ontlucht. De insteeknippel kan alleen worden ontkoppeld door deontkoppelingsring naar rechts te draaien.
DN6Non-interchangeable1/4˝
Key D Key F Key S Key V
Key
In een oogopslag
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
81tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
SV 2 - Stage
DN6QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
with female thread
PLUG STECKNIPPEL
A Key D Key F Key S Key V303 00 645303 00 388303 00 487303 00 389303 00 646303 00 390
303 00 650303 00 372303 00 489303 00 373303 00 651303 00 374
303 00 655303 00 396303 00 491303 00 397303 00 656303 00 398
303 00 660303 00 380303 00 493303 00 381303 00 661303 00 382
A Key D Key F Key S Key VG1/4NPT1/4G3/8NPT3/8G1/2
303 00 391303 00 488303 00 392303 00 648303 00 647
303 00 375303 00 490303 00 376303 00 653303 00 652
303 00 399303 00 492303 00 400303 00 658303 00 657
303 00 383303 00 494303 00 384303 00 663303 00 662
with male thread
with hose tail
75
28 D
52.5
28 A
66.5
28 A
A Key D Key F Key S Key V303 00 393303 00 394303 00 395303 00 649
303 00 377303 00 378303 00 379303 00 654
303 00 401303 00 402303 00 403303 00 659
303 00 385303 00 386303 00 387303 00 664
6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝13 mm 1/2˝
A Key D Key F Key S Key VG1/8G1/4NPT1/4
355 00 296355 00 297355 00 343
355 00 286355 00 287355 00 344
355 00 306355 00 307355 00 345
355 00 291355 00 292355 00 346
with male thread
with hose tail A Key D Key F Key S Key V355 00 298355 00 299355 00 300
355 00 288355 00 289355 00 290
355 00 308355 00 309355 00 310
355 00 293355 00 294355 00 295
6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝
Plug with check valve
A Key D Key F Key S Key VG1/4NPT1/4
353 00 253353 00 293
353 00 239353 00 297
353 00 260353 00 301
353 00 246353 00 305
with female thread
90
A
SW19
with male thread A Key D Key F Key S Key V
79
A
SW19
with hose tail A Key D Key F Key S Key V353 00 257353 00 258353 00 259
353 00 243353 00 244353 00 245
353 00 264353 00 265353 00 266
353 00 250353 00 251353 00 252
6 mm 1/4˝8 mm 5/16˝10 mm 3/8˝
100
D
SW17
1/4˝
G1/8G1/4NPT1/4G3/8NPT3/8G1/2
G3/8NPT3/8
353 00 254353 00 294
353 00 240353 00 298
353 00 261353 00 302
353 00 247353 00 306
55.5
D 15.5
36
A 16
G1/4NPT1/4
353 00 255353 00 295
353 00 241353 00 299
353 00 262353 00 303
353 00 248353 00 307
G3/8NPT3/8
353 00 256353 00 296
353 00 242353 00 300
353 00 263353 00 304
353 00 249353 00 308
82 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
SV 1-Stage
DN11Auf einen Blick
Verwechslung verschiedener Medienausgeschlossen, da nur mit Stecknippel mit gleichem Schlüssel zu betätigen
Robuste Ausführung
Einsatz bei Verwechslungsgefahr
AnwendungsbereichFür sicherheitsrelevante Anwendungen, toxische Medien in:• Anlagenbau• Raffinerien (Öl- und Gasindustrie)
HandhabungEinkuppelnStecknippel in Kupplung einführen, nach rechts drehen bis der Mechanismus hörbar einrastet.
AuskuppelnStecknippel nach links drehen und gleichzeitig den Auslösering leicht nach hinten ziehen. Um ein gefährliches Rückschlagen zu vermeiden, muss der Stecknippel so lange in der Hand gehalten werden bis der Schlauch vollständig entlüftet ist.
En brefInterversion de différents fluides impossible grâce à un profil de clé identique ducoupleur et de son about.
Modèle robuste
Application en cas de risque d’interversion
Domaine d’applicationPour les applications liées à la sécurité,les fluides toxiques, par ex.:• Construction d’installations• Raffineries (industrie du pétrole et du gaz)
ManipulationAccouplementIntroduire l’about de raccordement dans le coupleur et le tourner vers la droite jusqu’au déclic audible du mécanisme.
DésaccouplementTourner l’about de raccordement versla gauche et en même temps tirer la bague de déclenchement légèrement vers l’arrière. Pour éviter un coup de fouet du tuyau, il convient de garder l’about en main jusqu’à ce que le tuyau soit entièrement purgé.
In een oogopslagHet samenkomen van vloeistoffen is uitgesloten, doordat er alleen verbinding kan worden gemaakt via een plug met een identiek profiel
Bijzonder robuust ontwerp
Voorkomt het risico dat er verbinding wordt gemaakt met een onjuiste lijn
ToepassingsgebiedVeiligheidsgerelateerde toepassingen, giftige vloeistoffen:• Installatiebouw• Raffinaderijen (olie- en gasindustrie)
GebruikKoppelenDruk de insteeknippel in dekoppeling en draai naar rechts totdat het mechanisme hoorbaar een koppeling maakt.
OntkoppelenDraai de insteeknippel naar links entrek gelijktijdig de ontkoppelingsringvoorzichtig naar achteren. Om eengevaarlijke loskoppeling van de slangte vermijden, moet de insteeknippelmet de hand vast worden gehoudentotdat de slang volledig is ontlucht.
FeaturesMixing of different media is impossible as connection is only possible with plug withidentical key profile
Extremely robust design
Eliminates danger of wrong line connection
ApplicationFor safety-related applications, toxic media in:• Machine and apparatus engineering• Petrochemical (oil and gas industries)
ProcedureConnectionPush plug into coupling and turn it to the right until the mechanism is heard to engage by a click.
DisconnectionTurn plug to the left while simultaneously gently pulling back the release ring. In order to prevent the hose from ejecting dangerously, the plug must be held in the hand until the hose is completely ventilated.
Non-interchangeable Heavy-Duty Range1/2˝
Key
45°
135 °90°
45° 90° 135°
OptionsFDAFFKM EPDM
-20º to + 200ºC (FPM)
+5º to + 392ºF
STEEL
• Bis 25 bar, techn. Vakuum bis 100 mbar
• ein-/auskuppeln bis max. 15 bar
Betriebsdruck
• Jusqu’à 25 bar, Vide technique jusqu’à 100 mbar
• accouplement/ désaccouplement jusqu’à 15 bar max
Pression de service
• tot 25 bar, 100 mbar Vacuüm
• aan- en afkoppelen tot max. 15 bar
Werkdruk
• Up to 25 bar, Vacuum till 100 mbar
• connection/disconnection to max. 15 bar
Operating Pressure
83tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
DN11Keys 45°...90°...135°QUICK ACTION COUPLING SCHNELLVERSCHLUSS-KUPPLUNG
SV 1 - StageNon-interchangeable
1/2˝
A Key 45° Key 90° Key 135°G3/8G1/2NPT1/2G3/4NPT3/4
303 00 665303 00 666303 00 668303 00 667303 00 669
303 00 670303 00 671303 00 673303 00 672303 00 674
303 00 675303 00 676303 00 678303 00 677303 00 679
45°45°
135°135°
90°90°
45°45°
135°135°
90°90°
45°
135°
90°
A Key 45° Key 90° Key 135°G3/8NPT3/8G1/2NPT1/2G3/4G1
303 00 680303 00 684303 00 681303 00 685303 00 682303 00 683
303 00 686303 00 690303 00 687303 00 691303 00 688303 00 689
303 00 692303 00 696303 00 693303 00 697303 00 64303 00 695
45°45°
135°135°
90°90°
45°45°
135°135°
90°90°
45°
135°
90°
45°
135°
90°
A Key 45° Key 90° Key 135°G1/2NPT1/2
355 00 347355 00 348
355 00 351355 00 352
355 00 355355 00 356
45°45°
135°135°
90°90°
A Key 45° Key 90° Key 135°13 mm 1/2˝19 mm 3/4˝
355 00 349355 00 350
355 00 353355 00 354
355 00 357355 00 358
45°45°
135°135°
90°90°
A Key 45° Key 90° Key 135°G1/2NPT1/2
353 00 334353 00 335
353 00 341353 00 342
353 00 348353 00 349
45°45°
135°135°
90°90°
A Key 45° Key 90° Key 135°G1/2NPT1/2G3/4
353 00 336353 00 337353 00 338
353 00 343353 00 344353 00 345
353 00 350353 00 351353 00 352
45°45°
135°135°
90°90°
45° 135°
90°
A Key 45° Key 90° Key 135°13 mm 1/2˝19 mm 3/4˝
353 00 339353 00 340
353 00 346353 00 347
353 00 353353 00 354
45°45°
135°135°
90°90°
with female thread
PLUG STECKNIPPEL
with male thread
with female thread
with hose tail
Plug with check valve
with female thread
with male thread
with hose tail
A
108.5
Ø30
A
93.5
Ø30
D
130.5
Ø30
A
79
SW27
D
SW27
126
Ø50
79.2
A
Ø50
88.2
A
84 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
Performance Graph Air bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
3 4 5 7 10 15 20 m3/h
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
SV 1-Stage DN3 1/8˝
2 2.5 3 4 5 8 10 SCFM
Performance GraphStainless SteelFlow Rate at 68°F (20 °C)Operating Pressure 87 psi (6 bar)
Performance Graph Air SV 2-Stage DN6 1/4˝ Performance Graph WaterSV 2-Stage DN6 1/4˝ bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
7 10 15 20 30 40 SCFM
10 15 20 30 40 50 70 m3/h
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
2 3 4 6 10 20 30 60 l/min
0.6 0.8 1 1.5 2.5 5 10 15 GPM [US]
bar psi
10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150 100
50
30
15
107
5
3
2
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Performance Graph Air SV 2-Stage DN8 3/8˝ Performance Graph WaterSV 2-Stage DN8 3/8˝
Plug with check valve
Plug
Without valve OV
bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
20 30 40 50 70 100 m3/h
7 15 25 30 40 55 SCFM
5 10 20 30 40 60 100 l/min
1 2.5 5 8 10 15 25 GPM [US]
10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150
100
50
30
15
107
5
3
2
bar psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
85tst-tamsan.comTST-Tamsan reserves all rights to make changes and/or improvements of all products shown in catalogues.
Performance Graph Air bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
3 4 5 7 10 15 20 m3/h
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
SV 1-Stage DN3 1/8˝
2 2.5 3 4 5 8 10 SCFM
Performance GraphStainless SteelFlow Rate at 68°F (20 °C)Operating Pressure 87 psi (6 bar)
Performance Graph Air SV 2-Stage DN6 1/4˝ Performance Graph WaterSV 2-Stage DN6 1/4˝ bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
7 10 15 20 30 40 SCFM
10 15 20 30 40 50 70 m3/h
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
2 3 4 6 10 20 30 60 l/min
0.6 0.8 1 1.5 2.5 5 10 15 GPM [US]
bar psi
10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150 100
50
30
15
107
5
3
2
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Performance Graph Air SV 2-Stage DN8 3/8˝ Performance Graph WaterSV 2-Stage DN8 3/8˝
Plug with check valve
Plug
Without valve OV
bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
20 30 40 50 70 100 m3/h
7 15 25 30 40 55 SCFM
5 10 20 30 40 60 100 l/min
1 2.5 5 8 10 15 25 GPM [US]
10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150
100
50
30
15
107
5
3
2
bar psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Performance GraphStainless Steel
Flow Rate at 68°F (20 °C)Operating Pressure 87 psi (6 bar)
Performance Graph Air SV 2-Stage DN11 1/2˝ Performance Graph WaterSV 2-Stage DN11 1/2˝
Performance Graph Air SV 2-Stage & Heavy Duty DN11 1/2˝ Graph Water
Performance Graph AirSV 2-Stage DN6 1/4˝Non-Interchangeable Performance Graph WaterSV 2-Stage DN8 3/8˝
Plug with check valve
Plug
Without valve OV
30 40 50 70 100 200 300 m3/h
bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
20 30 50 100 150 SCFM
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
bar psi 10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150
100
50
30
15
107
5
3
2
5 10 20 30 40 60 100 200 l/min
1 3 5 10 15 25 50 GPM [US]
30 40 50 70 100 200 300 m3/h
bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
20 30 50 100 150 SCFM
SV 2-Stage & Heavy Duty DN11 1/2˝ bar psi 10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150
100
50
30
15
107
5
3
2
5 10 20 30 40 60 100 200 l/min
1 3 5 10 15 25 50 GPM [US]
bar psi
1.0
0.8
0.60.5
0.4
0.3
0.2
0.1
15
10
7
5
3
2
7 10 15 20 30 40 SCFM
10 15 20 30 40 50 70 m3/h 2 3 4 6 10 20 30 60 l/min
0.6 0.8 1 1.5 2 .5 5 10 15 GPM [US]
bar psi 10
6 5 4 3
2
1
0.60.50.40.3
0.2
0.1
150
100
50
30
15
107
5
3
2
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
Pr
essu
re d
iffer
ence
ø P
in b
ar a
nd p
si
Pres
sure
diff
eren
ce ø
P in
bar
and
psi
86 tst-tamsan.com TST - Tamsan complies with the quick coupling manufacturing instructions and standards of Oetiker A.G. after the acquisition of the coupling division in 2012.
ICON INDEXIcons Related with Application Area
The pressure ranges vary for each product shown in this leaflet. Before ordering, please mention the application pressure to make sure the product meets the system requirements.
Temperature range of our products vary according to the sealing components chosen. Most common sealing types are listed below. For custom requirements, please contact us.
Is the actual diameter which fluid passes through. TST is capable of manufacturing products with nominal diameter of DN 2,7 mm’s up to DN 75 mm’s.
FLOW SYMBOLS
THROUGH FLOW (Both Sides are Without Valve)
DOUBLE SHUT OFF (Both Sides are
With Valve)
SINGLE SHUT OFF (One side is With Valve)
OTHER ICONS
Swivel FFKMFKM FDA NBR
SWING COUPLING / SV SERIE / STAINLESS STEEL SERIE
www.tst-tamsan.com
TAMSAN BAĞLANTI ELEMANLARI A.Ş.
GEPOSB Gebze / Kocaeli TURKİYEFactory Tel: +90 262 751 20 44 Fax: +90 262 751 30 [email protected]
EXPORT DEPARTMENTTel: +90 262 751 20 25 Fax: +90 262 751 20 [email protected]
www.tst-tamsan.com