Quarterly journal of clinical and surgical ophthalmology and ...Michele Figus Paolo Fogagnolo Paolo...
Transcript of Quarterly journal of clinical and surgical ophthalmology and ...Michele Figus Paolo Fogagnolo Paolo...
Year 3 ı Number 2 ı June 2017
Trimestrale - In caso di mancato recapito rinviare all'Ufficio Postale di Savona CPO per la restituzione al mittente che si impegnerà a pagare la relativa tassa - Contiene I.P.
Quarterly journal of clinical and surgical ophthalmology and ophthalmic optics
ISSN 2421-3381
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique
Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
MIODESOPSIE o “mosche volanti”?
Italian Review of Ophthalmology
Year III n. 2 - GIUGNO 2017Autoriz. Tribunale di Milanon. 71 del 17/03/2015Iscrizione R.O.C. n. 21349
PublisherPublicomm SrlSavona - Piazza Guido Rossa 8/r Ph. +39-019 838411 Fax +39-019 8384141
Annual subscriptionItaly Euro 50,00Abroad Euro 125,00
SubscriptionsPh. 019 [email protected]
www.iroo.it
www.italianreviewofophthalmology.com/it/eu
Editor In ChiefSimona Finessi
Executive EditorLiviana Enrile [email protected]
Sales ManagerIlaria Foschi [email protected]
Art & Graphic DesignAngelo DaddaPaolo Veirana
Print Erredi Grafiche Editoriali S.n.c.16138 Genova - Via Trensasco, 11
Michele IesterAntonio FerrerasMichele FigusPaolo FogagnoloPaolo FrezzottiAngelo MacrìFrancesco Oddone Mariacristina Parravano
The current scientific colophon is valid for 2017. At the end of the year, it will be reviewed by the editorial staff to ensure an effective collaboration
La presente composizione del colofon scientifico è valida per il 2017 e sarà sottoposta a revisione da parte della redazione allo scadere di tale periodo per garantire una fattiva partecipazione
Italian Review of Ophthalmology
Quarterly journal of clinical and surgical ophthalmology and ophthalmic opticsRivista trimestrale di oftalmologia clinica e chirurgica e di ottica oftalmica
HeadingsRubriche
63
85
97
108
116
128
A. PASSANI, A. TINDARA SFRAMELI, C. POSARELLI, F. NASINI, R. DENARO, I. FRANCHINI:Minimally invasive surgery in the treatment of glaucoma: current status and future developmentsLa chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
L. MOTTA, A. SALICONE, G. ARIENZO, G. SEPE, C. DE MARTINO, A. NAPOLI, M. S. MOTTA:Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging systemRapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
M. ABBONDANZA, V. DE FELICE, G. ABBONDANZA:Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
FOCUS
NEWS DALLE AZIENDE CALENDARIO EVENTI
Scientific ArticlesArticoli Scientifici
sssuuuummmmmmmmaaaaarrrrryyyyy
Written contributions The authors of scientific articles and clinical cases (for whose content they assume full
responsibility) are requested to send their articles on digital media or via e-mail, complete
with text in Italian and English, together with images. They must supply telephone number,
fax number and e-mail address for communications with the editors.
In the accompanying letter the relative area of study of the topic should be stated and
selected from the following: clinical and surgical ophthalmology, semeiotics, visual neurophysiopathology, psychophysical vision, physical optics, refractive surgery, contact lenses, refractive pathology, binocular vision physiopathology, instruments and tools, epidemiology, general diseases and visual functions.
Articles should be laid out as follows:
• Title (max 90 characters)
• Author/s: full name and surname
• Institute of origin or work • Address for correspondence with the principal author (you should also indicate telephone number and fax for the editorial staff)
• Acknowledgements/financial support (optional)
• Key words in Italian
• Summary in Italian laid out as follows:
· Objective · Basic procedure · Results · Conclusions · Notes (optional)
• Key words in English • Summary in English laid out as follows:
· Basic procedure · Results · Conclusions · Notes (optional)
• Text in Italian and in English laid out as follows:
· Introduction and objective · Methodology · Results · Discussion · Conclusions · References
References
Abstracts and conference reports should be cited in the text and not the bibliography.
The bibliography should contain the following information in the following order:
magazine articles surname and initials (not punctuated) name or names of the author or authors,
title of the article, title of the magazine and volume number, pages on which the article
appears, and year of publication
example: Arnold AC, Hepler RS. Fluorescein angiography in acute nonarteritic anterior ischemic
optic neuropathy. Am J Ophthalmol 1994;17:222-30
printed articles surname and initials (not punctuated) name or names of the author or authors, title of
the chapter (if any), title of the book, editor (if any), place, publisher, year of publication,
pages referred to, or pages of the chapter cited
example: Mannis MJ. Bacterial conjuntivitis. In: The Cornea. Kaufman HE, Barron BA,
McDonald MB, Waltman SR, editors. New York: Churchill Livingstone, 1988:189-9
Images and tables Illustrations, tables and graphics should be attached with an indication of the
necessary references for their correct insertion within the article.
Abbreviations
The first time an abbreviation is to be used, the word should be written in full and its
abbreviation in brackets. Thereafter the abbreviation may be used.
Galley proofs, abstracts and correspondence with the editorial staffCorrections of the first drafts will be carried out by the authors, following corrections
will be carried out by the editorial staff.
Per le istruzioni per gli autori in italiano vai al link:http://www.iroo.it/istruzioni-autori/
Editorial guidelines
Aims of the magazine: scientific updates for
ophthalmologists, through the free
publication of original articles or
extracts from international journals
in this field.
Topics: original essays, research, clinical
testing and also case reports
aimed at supplying information on
events of interest to the sector or
related educational aspects.
The editorial staff will submit all
contributions regarding clinical
and surgical ophthalmology
in every aspect (visual
neurophysiopathology,
psychophysical vision, physical
optics, refractive surgery, contact
lenses, refractive surgery,
binocular vision physiopathology,
instruments and tools,
epidemiology, general diseases
and visual functions) to the
members of the scientific board.
Conditions of acceptance of contributions: contributions received will
only be published after having
passed the review system (two favourable reviews out of three)
as established by the scientific
board which has the right to refuse
publication or to request the
authors to make modifications or
changes in order for the presented
article to be publishable.
Editorial staff
Liviana EnrileItalian Review of OphthalmologyPublicomm SrlPiazza Guido Rossa 8r17100 Savona
tel. 019.838411fax 019.8384141
e-mail [email protected]
IIIIIIIInnnnnnnsssssstttttttrrrrrrruuuucccccctttttttttiiiiiiiooooooooooonnnnnnnnnnnnnnnnnssssssssssss ffffffffffffffooooooooooooooorrrrrrrrrrrrrr aaaaaaaaaaaaaaaaaauuuuuuuuuuuuuutttttttthhhhhhhhhoooooooooooooorrrrrrrrrrrrrrrrrrrrrssssssssssssssssssssssssss
Year 3 ı Number 2 ı 2017
CORRESPONDING AUTHORAndrea Passani
Azienda Ospedaliero-
Universitaria Pisana
Via Paradisa 2, Pisa
KEY WORDSGlaucoma, minimally
invasive surgery, minimally
invasive glaucoma surgery,
MIGS, Trabectome, iStent,
iStent Inject, GATT, ELT,
Hydrus, CyPass, iStent
Supra, XEN
PAROLE CHIAVEGlaucoma, chirurgia
mininvasiva, minimally
invasive glaucoma surgery,
MIGS, Trabectome, iStent,
iStent Inject, GATT, ELT,
Hydrus, CyPass, iStent
Supra, XEN
RIASSUNTOLa chirurgia mininvasiva del glaucoma si
è arricchita negli ultimi anni di numerose
nuove tecniche e devices e rappresenta
una valida alternativa alla chirurgia
filtrante tradizionale. Questa review
riassume brevemente le diverse tecniche
mininvasive ad oggi disponibili.
INTRODUZIONEIl glaucoma è una neuro-otticopatia cronica
a carattere evolutivo che rappresenta la
prima causa di cecità legale irreversibile
a livello mondiale1. Tradizionalmente il
suo trattamento si articola in una fase
iniziale a carattere conservativo (terapia
farmacologica e parachirurgica) ed in una
successiva fase a carattere invasivo (terapia
chirurgica). Nel corso degli anni sono state
introdotte numerose tecniche chirurgiche
differenti tra le quali la trabeculectomia, che
grazie all’elevato potere di riduzione della
pressione intraoculare (IOP) ed all’efficacia
a lungo termine, si è imposta come gold
standard del trattamento chirugrico2.
La trabeculectomia è tuttavia ancora
gravata da un tasso non trascurabile
di complicanze quali ipotalamia,
atalamia, leakage, ipoema, distacco di
coroide, edema corneale persistente e
maculopatia da ipotono3. A causa delle
possibili complicanze e dell’invasività della
ABSTRACTMinimally invasive glaucoma surgery
has been enriched in recent years with
several new techniques and devices.
It is a valid alternative to conventional
filtration surgery. This review briefly
summarises the various minimally
invasive techniques that are available
to date.
INTRODUCTIONGlaucoma is a chronically evolving
neuro-ophthalmic disease that is the
primary cause of legally acknowledged
irreversible blindness worldwide1.
Conventionally its treatment includes
an initial conservative phase
(pharmacological and parasurgical
therapy) and a subsequent invasive
phase (surgical therapy). Several
different surgical techniques have
been introduced in the course of the
years, among them trabeculectomy,
which is considered the gold
standard for surgical treatment due
to its powerful intraocular pressure
(IOP) reducing action and long-term
efficacy2. However, trabeculectomy
is still burdened by a non-negligible
incidence of complications, such as
hypoathalamia, athalamia, leakage,
hypoemia, choroidal detachment,
63
MINIMALLY INVASIVE SURGERY IN THE TREATMENT OF GLAUCOMA: CURRENT STATUS AND FUTURE DEVELOPMENTS
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
Andrea Passani1, Angela Tindara Sframeli1, Chiara Posarelli1, Francesco Nasini2,
Rosario Denaro3, Iacopo Franchini41Pisa University Hospital – University of Pisa2North-West Tuscany LHA (Former LHA no. 6) – Livorno3North-West Tuscany LHA (Former LHA no. 1) – Massa Carrara4Careggi University Hospital – University of Florence
64Minimally invasive surgery in the treatment of glaucoma: current status and future developments
procedura la trabeculectomia viene de
facto solitamente riservata a pazienti con
quadro anatomo-clinico avanzato nei
quali i benefici di un’importante riduzione
della IOP giustifichino i rischi connessi
all’intervento. La chirurgia “di bozza”, di
cui la trabeculectomia fa parte, presenta
inoltre altri svantaggi quali la possibile
cicatrizzazione della bozza, il leakage, lo
scarso risultato estetico e l’aumentato
rischio di endoftalmite3. Una cicatrizzazione
imprevedibile ed incontrollata rappresenta
nello specifico uno dei maggiori svantaggi
di questo tipo di chirurgia in quanto in
grado di determinare il fallimento del
trattamento chirurgico e la conseguente
necessità di re-intervento. Al fine di
minimizzare l’invasività della procedura
chirurgica e di evitare i rischi connessi
alla presenza di una bozza filtrante negli
ultimi anni sono state introdotte alcune
tecniche chirurgiche alternative che
vengono raggruppate sotto l’acronimo
“MIGS” ovvero di Minimally Invasive
Glaucoma Surgeries. Le tecniche MIGS
prevedono generalmente un approccio
ab-interno attraverso una piccola incisione
(<2 mm) in cornea chiara che permetta,
sotto visualizzazione gonioscopica,
di raggiungere l’angolo irido-corneale
che rappresenta il principale obiettivo
anatomico di questo tipo di chirurgia.
Nello specifico le varie tecniche MIGS
attualmente disponibili mirano ad ottenere
un aumento del deflusso di umor acqueo
attraverso lo sfruttamento delle fisiologiche
vie di deflusso (Trabectome, iStent, iStent
Inject, GATT, ELT ed Hydrus), dello spazio
sopracoroideale (Cy Pass, iStent Supra) o
dello spazio sottocongiuntivale (XEN).
I vantaggi offerti da queste nuove tecniche
sono rappresentati dal bassissimo
tasso di complicanze, dalla ripetibilità
della procedura chirurgica, dalla bassa
invasività, dal risparmio della congiuntiva
e dalla mancanza di una bozza filtrante
(eccetto il dispositivo XEN). Grazie a
persistent corneal oedema and
hypotonic maculopathy3.Due to the
possible complications and invasive
nature of the procedure, trabeculectomy
is typically reserved, in practice, for
patients presenting an advanced
anatomo-clinical picture in which
the beneficial effects of a major IOP
reduction justify the risks associated
with surgery. Moreover, “bleb” surgery,
which also includes trabeculectomy,
presents other disadvantages, such as
possible bleb scarring, leakage, poor
aesthetic outcome and increased risk
of endophthalmitis3. Unpredictable
and uncontrolled cicatrisation is
specifically one of the greatest
disadvantages of this type of surgery
because it can determine the failure of
surgical treatment and the subsequent
need for repeated surgery. In order
to minimise the invasiveness of the
surgical procedure and avoid the risks
associated with the presence of a
filtering bleb, some alternative surgical
techniques grouped under the acronym
“MIGS”, which stands for Minimally
Invasive Glaucoma Surgeries, have
been introduced in recent years. MIGS
techniques generally envisage an ab
interno approach by means of a small
incision (<2 mm) on a clear cornea in
order to reach, under the guidance of
gonioscopic imaging, the iridocorneal
angle, which is the main anatomical
target of this type of surgery. To be
precise, the various MIGS techniques
currently available are designed to
increase the aqueous humour outflow
by exploiting physiological routes
of discharge (Trabectome, iStent,
iStent Inject, GATT, ELT and Hydrus),
suprachoroidal space (Cy Pass, iStent
Supra) or subconjunctival space (XEN).
The benefits offered by these new
techniques include very low incidence
of complications, repeatability of the
65Year 3 ı Number 2 ı 2017
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
surgical procedure, low invasiveness,
sparing of the conjunctiva and absence
of a filtering bleb (with the exception of
the XEN device). Based on the above
characteristics, this new type of surgery
is proposed as an early therapeutic
alternative for the management of open-
angle glaucoma and might, therefore,
revolutionise our current diagnostic and
therapeutic approach to this important
condition. This paper briefly explains the
efficacy and safety of the main MIGS
techniques currently available.
TrabectomeTrabectome (NeoMedix Inc., Tustin,
CA, USA) is an electrocautery that
uses heat to ablate the trabeculate
and the internal wall of Schlemm’s
canal, thus allowing the direct outflow
of aqueous humour from the anterior
chamber to the collector channels.
The instrument’s handpiece has an
infusion and a suction route for residual
trabeculate, and is inserted into the
anterior chamber through a corneal
incision of circa 2 mm. This surgical
technique is also called “ab interno
trabeculotomy”, and can be extensively
customised, since it can ablate the
trabeculate for a circumference range
of 60-150 degrees4.This technique,
which was initially conceived only for
primary open-angle glaucoma, was
later applied successfully also to other
forms of glaucoma, such as exfoliative
glaucoma, pigmentary glaucoma,
post uveitic glaucoma, associated with
idiopathic juvenile arthritis and induced
by corticosteroids5,6. Trabectome has
been widely used especially in the USA,
and more than 50,000 ascertained
operations can be counted at present.
Several studies have been conducted
on the efficacy and safety of
Trabectome. The first one was by
Minckler in 2006. The study enrolled
queste caratteristiche questo nuovo tipo
di chirurgia si propone come alternativa
terapeutica precoce nella gestione del
glaucoma ad angolo aperto e potrebbe
quindi rivoluzionare il nostro attuale
approccio diagnostico-terapeutico a
questa importante patologia.
Il presente articolo si propone di illustrare
brevemente le caratteristiche di efficacia
e sicurezza delle principali tecniche MIGS
attualmente disponibili.
TrabectomeIl Trabectome (NeoMedix Inc., Tustin,
CA, USA) è un elettrocauterio che utilizza
l’energia termica per ablare il trabecolato
e la parete interna del canale di Schlemm
permettendo quindi il deflusso diretto
dell’umor acqueo dalla camera anteriore
ai canali collettori.
Il manipolo dello strumento è dotato
di una via d’infusione e d’aspirazione
per i residui del trabecolato e viene
introdotto in camera anteriore attraverso
un’incisione corneale di circa 2 mm.
Questa tecnica chirurgica viene anche
chiamata “trabeculotomia ab interno” e
può essere largamente personalizzata in
quanto è possibile ablare il trabecolato
per un’estensione variabile dai 60 ai
150 gradi di circonferenza4. Questa
tecnica, concepita inizialmente per il solo
glaucoma primario ad angolo aperto,
è stata successivamente applicata
con successo anche ad altre forme di
glaucoma quali il glaucoma esfoliativo,
pigmentario, post-uveitico, correlato
ad artrite idiopatica giovanile ed indotto
da corticosteroidi5,6. L’utilizzo del
Trabectome ha avuto larga diffusione
soprattutto negli USA ed al momento
attuale si contano più di 50000 interventi
accertati. Sull’efficacia e la sicurezza
del Trabectome sono stati condotti
numerosi studi.
Il primo è quello di Minckler del 2006
per il quale furono arruolati 37 pazienti
66
affetti da glaucoma primario ad angolo
aperto (primary open-angle glaucoma
“POAG”). In questi pazienti l’impiego
della trabeculectomia ab interno
determinò una riduzione della IOP
media da 28.2±4.4 mmHg del baseline
a 16.3±2.0 mmHg ad un anno e da
27.6±7.2 mmHg a 15.2±2.4 mmHg a due
anni (durante l’estensione dello studio che
coinvolse 101 soggetti)4,6. Un successivo
studio del 2008 ha inoltre testato la
capacità ipotonizzante dell’intervento
combinato di trabeculotomia ab interno
+ facoemulsificazione di cataratta ed
impianto di IOL. Nei 304 pazienti arruolati
si osservò una riduzione della IOP media
da 20.0±6.3 mmHg del baseline a
15.5±2.9 mmHg del controllo ad un anno
(riduzione del 22.5%). Anche il numero
medio dei colliri anti-glaucoma passò da
2.7±1.1 della visita pre-operatoria a 1.4±1.3
del controllo ad un anno7. Simili risultati
sono stati ottenuti anche da Ahuja et al
che nel 2013 compararono un gruppo di
pazienti sottoposti ad intervento di sola
trabeculotomia ab interno ad un gruppo di
pazienti sottoposti ad intervento combinato
Trabectome + facoemulsificazione di
cataratta ed impianto di IOL. La PIO
media dei pazienti sottoposti a sola
trabeculotomia ab interno passò da
25.9±8.9 mmHg della visita pre-operatoria
a 16.8±2.8 mmHg della visita di controllo a
due anni (riduzione della IOP del 35.1%).
I pazienti sottoposti ad intervento
combinato registrarono invece una
riduzione percentuale della IOP media del
22.8% (passando da 19.3±7.4 mmHg del
baseline a 14.9±4.9 mmHg a due anni).
Nel complesso si osservò che ben il
62% dei pazienti sottoposti ad intervento
chirurgico raggiunse l’obiettivo terapeutico
prefissato (riduzione della IOP di almeno il
20% e IOP finale ≤ 21 mmHg)8.
Dal punto di vista della sicurezza il
principale evento avverso associato all’uso
di Trabectome è rappresentano dalla
37 patients with primary open-angle
glaucoma (POAG). In these patients
the performance of ab interno
trabeculectomy determined a reduction
in mean IOP from 28.2±4.4 mmHg at
baseline to 16.3±2.0 mmHg at one
year, and from 27.6±7.2 mmHg to
15.2±2.4 mmHg at two years (during
the extension period of the study that
involved 101 subjects)4,6. A subsequent
study conducted in 2008 also tested
the pressure reducing capacity of
combined ab interno trabeculotomy +
cataract phacoemulsification and IOL
implantation. A reduction in mean IOP
from 20.0±6.3 mmHg at baseline to
15.5±2.9 mmHg to the follow-up at one
year (22.5% reduction) was observed
in the 304 patients enrolled. Even
the mean number of anti-glaucoma
eyedrops shifted from 2.7±1.1 of the
preoperative visit to 1.4±1.3 of the
follow-up visit at one year7. Similar
results were obtained also by Ahuja
et al who, in 2013, compared a group
of patients who were submitted
only to ab interno trabeculotomy
surgery against a group of patients
submitted to combined Trabectome +
cataract phacoemulsification and IOL
implantation. The mean IOP of patients
submitted to ab interno trabeculotomy
alone shifted from 25.9±8.9 mmHg at
the preoperative visit to 16.8±2.8 mmHg
at the follow-up visit at two years (35.1%
IOP reduction). Patients submitted to
combined surgery, instead, recorded a
22.8% reduction in mean IOP (shifting
from 19.3±7.4 mmHg at baseline to
14.9±4.9 mmHg at two years). Overall,
it was observed that 62% of patients
submitted to surgery achieved the
established therapeutic goal (at least
20% IOP reduction and final IOP
≤ 21 mmHg)8.
In terms of safety, the main adverse
event associated with the use of
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
Year 3 ı Number 2 ı 2017 67
comparsa di spikes pressori nella prima
giornata post-operatoria che possono
essere agevolmente gestiti tramite la
sola terapia medica4,6-8. La comparsa di
modesto ipoema in camera anteriore si
osserva in quasi tutti i pazienti sottoposti
ad intervento e si risolve spontaneamente
nel giro di una settimana. Negli studi
clinici citati non si sono verificati casi di
distacco di coroide, ipotonia con atalamia,
endoftalmite o leakage4-8.
In base agli studi clinici a nostra
disposizione la trabeculotomia ab interno
mediante Trabectome appare essere
una procedura sicura ed efficace ma
al momento attuale mancano studi
randomizzati comparativi che validino
scientificamente questa ipotesi.
iStentL’iStent (Glaukos, Laguna Hills, CA, USA) è
un dispositivo cavo in titanio a forma di “L”
con una lunghezza di 1 mm ed un’altezza
di 0.3 mm (Fig. 1). Questo impianto è
progettato per essere inserito all’interno
del canale di Schlemm in modo da creare
un passaggio diretto tra questa struttura
e la camera anteriore. In merito al suo
inserimento esso viene condotto tramite un
Trabectome is the appearance
of pressure spikes on the first
postoperative day that can be easily
managed with medical therapy
alone4,6-8. The onset of moderate
hypoemia in the anterior chamber
is observed in almost all patients
submitted to surgery and resolves
spontaneously in one week. No cases
of choroidal detachment, hypotonia with
athalamia, endophthalmitis or leakage
occurred in the clinical studies cited4-8.
Based on the clinical studies at our
disposal, ab interno trabeculotomy
performed with Trabectome seems
to be a safe and effective procedure,
although at present there are no
comparative randomised studies to
scientifically validate this theory.
iStentiStent (Glaukos, Laguna Hills, CA, USA)
is a hollow “L”-shaped titanium device
that is 1 mm long and 0.3 mm high
(Fig. 1). This implant is designed to be
inserted into Schlemm’s canal in order
to create a direct passage between this
structure and the anterior chamber. It is
inserted using a dedicated inserter, with
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
1Fig.
Fig. 1First generation iStent
(Courtesy of Glaukos)
iStent di prima generazione
Snorkel
Lumen120 μm
RetentionArches
Self-TrephiningTip
Rail 1 mm
68
apposito inseritore e prevede che il braccio
lungo del dispositivo penetri all’interno del
canale di Schlemm mentre il braccio corto
dello stesso aggetti in camera anteriore
permettendo il flusso di umor acqueo.
Il razionale che sta alla base di questo
impianto è quello di permettere all’umor
acqueo di superare la principale sede di
resistenza al flusso che, nel glaucoma
primario ad angolo aperto, è rappresentata
dal trabecolato9.
Dopo i primi studi pilota di Spiegel del
2007 e 20089,10 e di Fea11 del 2010 è stato
Samuelson12 a riportare i risultati del primo
studio multicentrico su vasto campione.
Lo studio clinico fu condotto su 240 occhi
confrontando l’efficacia dell’intervento
combinato di cataratta + impianto di iStent
vs il solo intervento di cataratta.
Ad un anno dall’intervento il 72%
dei pazienti sottoposti ad intervento
combinato presentava una IOP media
≤ 21 mmHg senza terapia farmacologica
contro il 50 % dei pazienti sottoposti al
solo intervento di cataratta. Il 66% dei
pazienti sottoposti ad intervento combinato
mostrava inoltre una riduzione della IOP
di almeno il 20% rispetto al valore basale
(senza terapia farmacologica) contro il 48%
dei pazienti sottoposti al solo intervento
di cataratta. Il follow-up a due anni ha
confermato che il 61% dei pazienti con iStent
manteneva una IOP media ≤ 21 mmHg
senza terapia topica contro il 50% dei
pazienti sottoposti al solo intervento di
facoemulsificazione13 .
Dal punto di vista della sicurezza l’impianto
di iStent ha un profilo di rischio paragonabile
a quello del solo intervento di cataratta. Le
principali complicanze chirurgiche sono
rappresentate dal mal posizionamento e
dall’occlusione precoce del dispositivo
che possono essere gestite con la
semplice osservazione o con l’impiego di
procedure chirurgiche secondarie (Nd:YAG
laser, gonioplastica con Argon laser o
riposizionamento dello stent)9-14.
the long arm of the device penetrating
into Schlemm’s canal and the short arm
projecting into the anterior chamber
and permitting the outflow of aqueous
humour. The rationale that underpins this
implant is to allow aqueous humour to
bypass the main site of resistance to flow
that, in primary open-angle glaucoma, is
the trabeculate9.
After the first pilot studies conducted
by Spiegel in 2007 and 20089,10, and by
Fea11 in 2010, Samuelson12 reported the
results of the first multicentre study on
a large patient population. The clinical
trial was conducted on 240 eyes by
comparing the efficacy of combined
cataract + iStent implantation surgery
vs. cataract surgery alone. At one year
after surgery, 72% of patients submitted
to combined surgery presented a mean
IOP ≤21 mmHg without pharmacological
therapy vs. 50% of patients submitted to
cataract surgery alone. 66% of patients
submitted to combined surgery also
presented a reduction in IOP by at least
20% compared to the baseline value
(without pharmacological therapy) vs.
48% of patients submitted to cataract
surgery alone. The follow-up visit at two
years confirmed that 61% of patients
with iStent maintained a mean IOP
≤21 mmHg without topical therapy
vs. 50% of patients subjected to
phacoemulsification surgery alone13.
In terms of safety, the iStent implant has
a risk profile that is comparable to that of
cataract surgery alone. The main surgical
complications are poor positioning and
early occlusion of the device that can
be managed with simple observation
or by resorting to secondary surgical
procedures (Nd: YAG laser, Argon laser
gonioplasty or stent repositioning)9-14.
iStent InjectiStent Inject (Glaukos, Laguna Hills,
CA, USA) is the result of the evolution
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
Year 3 ı Number 2 ı 2017 69
iStent InjectL’iStent Inject (Glaukos, Laguna Hills, CA,
USA) è nato dall’evoluzione dell’iStent di
prima generazione e consiste in un device
cavo in titanio di forma rettilinea dalla
lunghezza di 0.36 mm (Fig. 2). Come per il
precedente modello il device deve essere
impiantato nell’angolo irido-corneale in
modo da ottenere un passaggio diretto
dell’umor acqueo dalla camera anteriore al
canale di Schlemm. Diversamente dal suo
predecessore l’iStent Inject viene tuttavia
impiantato tramite un apposito inseritore
che presenta due devices precaricati e
non richiede un movimento laterale per il
corretto impianto dello stent. La presenza
di due stent precaricati (invece di uno solo)
è dovuta al fatto che diversi studi clinici
hanno dimostrato una maggior efficacia
ipotonizzante del duplice impianto rispetto
all’impianto di un solo device.
Dal punto di vista dell’efficacia
Fernàndez-Barrientos ha dimostrato una
riduzione media della IOP del 27% nei
pazienti sottoposti ad intervento combinato
di cataratta + impianto di 2 iStent Inject vs
una riduzione della IOP del 16% del gruppo
di controllo sottoposto al solo intervento
di cataratta (dati ad un anno).
of the first generation iStent and
consists of a straight hollow titanium
device that is 0.36 mm long (Fig. 2). As
with the previous model, the device
must be implanted in the iridocorneal
angle to obtain a direct transit of
aqueous humour from the anterior
chamber to Schlemm’s canal. Unlike
its predecessor, however, iStent
Inject is implanted with a dedicated
inserter that presents two preloaded
devices and does not require a lateral
movement for the correct implantation
of the stent.
The presence of two preloaded stents
(instead of only one) is due to the fact
that various clinical trials have reported
a greater pressure-reducing efficacy
of the dual implant, compared to
implantation of only one device.
In terms of efficacy,
Fernàndez-Barrientos reported a
mean 27% reduction in IOP in patients
submitted to combined cataract
surgery + implantation of 2 iStent
Inject vs. a 16% reduction in IOP in
the control group that was submitted
to cataract surgery alone (data at one
year). Moreover, the mean number of
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
2Fig.
Fig. 2iStent Inject
(Courtesy of Glaukos)
0,36 mm
70
Anche il numero medio di farmaci
anti-glaucoma si è dimostrato inferiore
nel gruppo sottoposto ad impianto di
iStent (0.0) rispetto al gruppo di controllo
(0.7)15. Risultati similari sono stati ottenuti
anche dal successivo studio clinico di
Belovay del 201216.
Il profilo di sicurezza dell’iStent Inject è
del tutto paragonabile a quello dell’iStent
di prima generazione di cui condivide le
stesse principali complicanze.
La comparsa d’ipertono incoercibile in
una piccola serie di pazienti affetti da
glaucoma pigmentario controindica
l’impiego di iStent Inject in questa
sottopopolazione di pazienti anche
se sono necessari ulteriori studi clinici
in merito17.
Gonioscopy-Assisted Transluminal Trabeculotomy (GATT)La GATT è una nuova tecnica chirurgica
che è stata descritta per la prima volta
da Grover nel 201418. Questa tecnica
prevede la creazione di due incisioni
corneali (una temporale ed una supero/
infero-nasale) attraverso cui, sotto
visualizzazione gonioscopica, viene
creata una goniotomia circa 1-2 mm. Una
volta creata la goniotomia si procede ad
inserire all’interno del canale di Schlemm
un microcatetere illuminato nella sua
estremità distale (iTrack, Ellex, Adelaide,
Australia). Il microcatetere viene spinto
all’interno del canale di Schlemm per
360° ovvero finché la sua estremità
distale non ricompare all’interno della
goniotomia inizialmente creata. Una volta
incannulato per 360° il canale di Schlemm
si procede con il tirare l’estremità distale
del microcatetere in modo da asportare
meccanicamente il trabecolato e mettere
in comunicazione diretta la camera
anteriore con il canale di Schlemm.
Tutte le procedure descritte vengono
eseguite sotto viscoelastico che viene
poi rimosso a fine intervento tramite
anti-glaucoma drugs was lower in the
group submitted to iStent implantation
(0.0) vs. the control group (0.7).15
Similar results were also obtained from
the subsequent clinical trial conducted
by Belovay in 201216.
The safety profile of iStent Inject is
entirely comparable to that of the
first generation iStent, with the same
main complications. The onset of
incoercible hypertonus in a small
series of patients with pigmentary
glaucoma contraindicates the use of
iStent Inject in this sub-population of
patients, though further clinical studies
are required in this regard17.
Gonioscopy-Assisted Transluminal Trabeculotomy (GATT)GATT is a new surgical technique
that was described for the first time
by Groverin 201418. This technique
envisages the creation of two corneal
incisions (one temporal and one
superior/inferior nasal) through which a
goniotome of circa 1-2 mm is created
under gonioscopic guidance. A lighted
microcatheter is then inserted into
the distal end of Schlemm’s canal
(iTrack, Ellex, Adelaide, Australia).
The microcatheter is pushed into
Schlemm’s canal for 360° or until its
distal end re-appears inside the initially
created goniotome. After intubating
Schlemm’s canal for 360°, the process
continues by pulling the distal end of the
microcatheter to mechanically remove
the trabeculate and establish a direct
communication between the anterior
chamber and Schlemm’s canal.
All procedures described are carried out
with the use of a viscoelastic substance
that is removed at the end of surgery
by means of the Irrigation/Suction
handpiece.
The efficacy of GATT was reported by
Grover in a study involving 55 patients
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
Year 3 ı Number 2 ı 2017 71
manipolo Irrigazione/Aspirazione.
L’efficacia della GATT è stata riportata
dallo stesso Grover in uno studio che
ha coinvolto 55 pazienti affetti da POAG
e sottoposti ad intervento di GATT
eventualmente associato ad intervento
di cataratta. A 12 mesi dall’intervento si è
registrata una riduzione media della IOP
di 7.7±6.2 mmHg (pari al 30±20%) ed una
riduzione del numero medio di farmaci
anti-glaucoma di 0.9±1.318. La GATT è
stata inoltre impiegata in un gruppo di 35
pazienti precedentemente sottoposti ad
altra chirurgia per glaucoma nei quali ha
determinato una riduzione della IOP media
da 25.7 mmHg a 15.4 mmHg a 24 mesi ed
una riduzione dei farmaci anti-glaucoma
da 3.2 a 2.019.
L’evento avverso che più frequentemente
si associa alla GATT è l’ipoema che,
similarmente alla trabeculectomia ab
interno con Trabectome, solitamente
si risolve spontaneamente entro una
settimana. Altri eventi aversi associati alla
GATT sono rappresentati dall’ipotono con
atalamia (1 caso su 55 pazienti) e dalla
comparsa di distacco di coroide (1 caso
su 55 pazienti) che solitamente si risolvono
entro un mese dall’intervento.
Excimer Laser Trabeculotomy (ELT)L’ELT è una tecnica chirurgica che
prevede la fotoablazione selettiva del
trabecolato con conseguente formazione
di una comunicazione diretta tra camera
anteriore e canale di Schlemm. L’energia
per ottenere la fotoablazione del
trabecolato è fornita da un laser XeCl con
lunghezza d’onda di 308 μm ed una pulse
energy di 1.2 mJ20. La sonda laser viene
introdotta in camera anteriore tramite
un’incisione corneale e viene posta a
diretto contatto con il trabecolato.
Una volta ottenuto il contatto si procede
con l’emissione di energia che determina
la formazione di spots di fotoablazione
(di 200 μm di diametro); il numero e la
with POAG who were submitted to
GATT, associated with cataract surgery,
if necessary. A mean reduction of
7.7±6.2 mmHg in IOP (equal to 30±20%)
and a 0.9±1.3 reduction in the mean
number of anti-glaucoma drugs were
recorded at 12 months after surgery18.
GATT was also performed in a group
of 35 patients who were previously
submitted to other glaucoma surgery.
In these patients it determined a
reduction in mean IOP from 25.7 mmHg
to 15.4 mmHg at 24 months, and a
reduction in anti-glaucoma drugs from
3.2 to 2.019.
The adverse event that is most often
associated with GATT is hypoemia
that, like the ab interno trabeculectomy
performed with Trabectome, usually
resolves spontaneously within one
week. Other adverse events associated
with GATT are hypotonus with athalamia
(1 case out of 55 patients) and the onset
of choroidal detachment (1 case out of
55 patients) that usually resolve within
one month from surgery.
Excimer Laser Trabeculotomy (ELT)ELT is a surgical technique that
envisages selective photoablation of the
trabeculate with subsequent formation
of direct communication between
the anterior chamber and Schlemm’s
canal. The energy for the photoablation
of the trabeculate is provided by an
XeCl laser with 308 μm wavelength
and 1.2 mJ pulse energy20. The laser
probe is introduced into the anterior
chamber by means of a corneal incision
and is placed in direct contact with the
trabeculate. After obtaining contact,
the procedure continues with the
emission of energy that determines the
formation of photoablation spots (with
200 μm diameter). The number and
size of the spots can be customised
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
72
(the original technique envisages 8-10
spots at a distance of 500 μm from
each other). Two laser probes can be
used in this procedure, precisely the
first one (AIDA, Glautec AG, Nurnberg,
Germany) requires gonioscopic
guidance, whereas the second one
(AIDA, TUI-laser, Munich, Germany)
does not require gonioscopy because
the trabeculate can be directly seen by
means of endoscopy.
In terms of pressure-reducing efficacy,
Babighian compared ELT against the
most conventional SLT treatment, and
underscored a 29.6% reduction in mean
IOP at two years in the ELT group vs. a
21% reduction in mean IOP in the SLT
group. Even the success percentage
(defined as an IOP reduction of at
least 20% without pharmacological
treatment) was higher in the group
treated with ELT (53.3%), compared to
the group submitted to SLT (40%)21.
The studies conducted to date do not
indicate any adverse effect worthy of
note, thus defining a very high safety
profile20-22. Further clinical studies
are, however, necessary to clarify
the efficacy and safety profile of this
technique.
HydrusHydrus (Ivantis, Irvine, CA, USA) is a
half-moon-shaped device with overall
length 8 mm. It is made of a nickel-
titanium alloy called Nitinol (Fig. 3).
This device has a memory of shape,
presents broad lateral apertures that
allow the transit of aqueous humour, and
has a small 1 mm proximal aperture that
projects into the anterior chamber.
The device is designed to be inserted
into Schlemm’s canal to broaden the
lumen 4-5-fold, and prevent the collapse
of the canal structure associated with
the IOP increase23. Hydrus is positioned,
under gonioscopic guidance, by means
dimensione degli spots può essere
customizzata (nella tecnica originale
sono previsti 8-10 spots alla distanza
di 500 μm l’uno dall’altro). Le sonde
laser che possono essere impiegate in
questa procedura sono due: la prima
(AIDA, Glautec AG, Nurnberg, Germany)
richiede una guida gonioscopica mentre
la seconda (AIDA, TUI-laser, Munich,
Germany) non richiede gonioscopia
in quanto il trabecolato è direttamente
visualizzabile per via endoscopica.
Dal punto di vista dell’efficacia
ipotonizzante Babighian ha comparato
l’ELT al più tradizionale trattamento SLT
ed ha evidenziato una riduzione della IOP
media del 29.6% a due anni nel gruppo
ELT vs una riduzione della IOP media del
21% nel gruppo SLT. Anche la percentuale
di successo (definito come riduzione della
IOP di almeno il 20% senza trattamento
farmacologico) è risultata superiore nel
gruppo trattato con ELT (53,3%) rispetto al
gruppo sottoposto ad SLT (40%)21.
Gli studi attualmente disponibili non
indicano alcun effetto avverso degno di
nota delineando pertanto un profilo di
sicurezza molto elevato20-22. Ulteriori studi
clinici sono tuttavia necessari per chiarire
il profilo di efficacia e sicurezza di questa
tecnica.
HydrusL’Hydrus (Ivantis, Irvine, CA, USA) è
un device di forma semilunare della
lunghezza complessiva di 8 mm
costituito da una lega di nichel-titanio
detta Nitinol (Fig. 3). Questo device è
dotato di memoria di forma, presenta
ampie aperture laterali che consentono il
passaggio di umor acqueo ed è dotato di
una piccola apertura prossimale di 1 mm
che aggetta in camera anteriore. Il device
è progettato per essere inserito all’interno
del canale di Schlemm in modo da
ottenerne un allargamento del lume di 4-5
volte ed evitare il collasso della struttura
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
Year 3 ı Number 2 ı 2017 73
of a preloaded inserter that is introduced
into the anterior chamber through a
corneal incision of 1-1.5 mm.
A recent randomised study compared
the pressure-reducing efficacy of
combined phacoemulsification cataract
surgery + Hydrus implantation against
the pressure-reducing efficacy of
cataract surgery alone. In the group
submitted to cataract surgery and
Hydrus implantation, the mean IOP
diminished from 26.3±4.4 mmHg at
baseline to 16.9±3.3 mmHg at the
follow-up visit at 24 months, whereas
in the control group the mean IOP
diminished from 26.6±4.2 mmHg to
19.2±4.7 mmHg. Patients submitted to
Hydrus implantation also presented a
reduction in IOP of at least 20% in 80%
of cases vs. 46% of patients who were
submitted to cataract surgery24.
In the clinical trial conducted by Pfeiffer
the implantation of Hydrus did not entail
any variation in the risk profile, compared
to the control group (phacoemulsification
surgery and IOL implantation)24.
In the study conducted by Gandolfi
et al, the device was retrospectively
compared to canalplasty surgery with a
two year follow-up period. In the group
submitted to canalplasty, IOP diminished
from 26.0±4.0 mmHg to 16.0±2.0
mmHg, whereas in the group treated
with Hydrus, IOP diminished from
24.0±6.0 mmHg to 15.0±3.0 mmHg
canalicolare associato all’aumento
della IOP23. L’Hydrus viene posizionato,
sotto guida gonioscopica, grazie ad un
inseritore precaricato che viene introdotto
in camera anteriore attraverso un’incisione
corneale di 1-1.5 mm.
Un recente studio randomizzato ha
comparato l’efficacia ipotonizzante
dell’intervento combinato di
facoemulsificazione di cataratta +
impianto Hydrus e l’efficacia ipotonizzante
del solo intervento chirurgico per
cataratta. Nel gruppo sottoposto ad
intervento di cataratta ed impianto
Hydrus la IOP media si è ridotta
da 26.3±4.4 mmHg del baseline a
16.9±3.3 mmHg del controllo a 24 mesi
mentre nel gruppo di controllo la IOP
media si è ridotta da 26.6±4.2 mmHg a
19.2±4.7 mmHg.
I pazienti sottoposti ad impianto Hydrus
hanno inoltre presentato una riduzione
della IOP di almeno il 20% nell’80% dei
casi vs il 46% dei pazienti sottoposti al solo
intervento di cataratta24.
Nello studio clinico di Pfeiffer l’impianto
di Hydrus non ha comportato alcuna
variazione del profilo di rischio rispetto
al gruppo di controllo (intervento di
facoemulsificazione ed impianto IOL)24.
Nello studio condotto da Gandolfi et al
il dispositivo è stato retrospettivamente
paragonato all’intervento di canaloplastica
con un follow-up di due anni. Nel
gruppo sottoposto a canaloplastica
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
3Fig.
Fig. 3Hydrus positioned inside
Schlemm’s canal
Hydrus posizionato
all’interno del canale
di Schlemm
74
without any statistically significant
difference between the two procedures.
The complete success in the group
submitted to Hydrus was 33% vs. 50%
in the group submitted to canalplasty.
The failure percentage was respectively
9.5% in the group treated with Hydrus
and 8.3% in the canalplasty group25.
Further clinical trials are required to
clarify the efficacy and safety profile of
this device.
CyPassUnlike the above techniques that aim
at increasing the aqueous humour flow
through Schlemm’s canal, CyPass
(Transcend Medical, Menlo Park, CA,
USA – Alcon, Basel, Switzerland) is
a device designed to increase the
outflow of aqueous humour through the
suprachoroidal space (Fig. 4). The device
is made of polyamide and presents an
overall length of 6.35 mm with 510 μm
external diameter. Its cylindrical shape
envisages the presence of a proximal
circular aperture that projects into the
anterior chamber, and a distal aperture
that allows the longitudinal aqueous
humour outflow into the suprachoroidal
space. Besides the distal and proximal
apertures, the device presents
microscopic holes in its lateral walls that
allow the transversal aqueous humour
outflow into the suprachoroidal space.
la IOP si è ridotta da 26.0±4.0 mmHg
a 16.0±2.0 mmHg mentre nel gruppo
trattato con Hydrus la IOP si è ridotta
da 24.0±6.0 mmHg a 15.0±3.0 mmHg
senza alcuna differenza statisticamente
significativa tra le due procedure.
Il successo completo nel gruppo
sottoposto ad Hydrus è stato del 33%
vs il 50% del gruppo sottoposto a
canaloplastica; la percentuale di fallimento
è stata rispettivamente del 9,5% del
gruppo con Hydrus e del 8,3% nel gruppo
canaloplastica25.
Ulteriori studi clinici sono necessari per
chiarire il profilo di efficacia e sicurezza di
questo device.
CyPassDiversamente dalle tecniche
sopradescritte che mirano ad aumentare
il flusso di umor acqueo attraverso il
canale di Schlemm, il CyPass (Transcend
Medical, Menlo Park, CA, USA –
Alcon, Basel, Switzerland) è un device
progettato per aumentare il deflusso di
umor acqueo attraverso lo spazio sovra-
coroideale (Fig. 4). Il device è costituito
da Poliamide e presenta una lunghezza
complessiva di 6.35 mm ed un diametro
esterno di 510 μm. La sua forma cilindrica
prevede la presenza di un’apertura
circolare prossimale che aggetta in
camera anteriore ed un’apertura distale
che permette il deflusso longitudinale
Minimally invasive surgery in the treatment of glaucoma: current status and future developments
4Fig.
Fig. 4Cypass positioned in the
suprachoroidal space
(gonioscopic view)
Cypass posizionato nello
spazio sovracoroideale
(visione gonioscopica)
Year 3 ı Number 2 ı 2017 75
CyPass is implanted under gonioscopic
imaging of the angle with a dedicated
preloaded inserter, which is introduced
into the anterior chamber through a
corneal incision of 1.5 mm. The correct
positioning in the suprachoroidal
space can be confirmed with an OCT
examination of the anterior segment26.
A recent multicentre study confirmed the
pressure-reducing efficacy of CyPass
in the treatment of primary open-angle
glaucoma. The study involved 65
subjects who were submitted to CyPass
implantation. The mean IOP of the study
group diminished from 24.5±2.8 mmHg
to 16.4±5.5 mmHg at one year after the
implant. Even the mean number of anti-
glaucoma drugs diminished from 2.2±1.1
to 1.4±1.3. 27 A recent study with 2-year
follow-up obtained similar results (37%
reduction in IOP and reduction in the
mean number of anti-glaucoma drugs
from 2.0 to 1.1)28.
The main adverse events associated
with CyPass implantation include
hypotonus (13.8%), progression of lens
opacity at one year (12.2%), onset of
pressure spikes in the first postoperative
month (10.5%) and onset of persistent
inflammation (4.4%)27,28. As with the
above devices, in this case too, further
clinical trials are required to clarify the
efficacy and safety profile of this product.
iStent SupraiStent Supra (Glaukos, Laguna Hills,
CA, USA) is the latest evolution of
the devices produced by Glaukos
but, unlike its predecessors, whose
therapeutic targets are the trabeculate
and Schlemm’s canal, this device
is designed to establish a direct
communication between the anterior
chamber and the suprachoroidal space
(Fig. 5). The device presents a cylindrical
shape and a slight curvature to better
adapt to the anatomy of the ocular bulb.
dell’umor acqueo nello spazio
sovracoroideale. Oltre alle aperture
distale e prossimale il device presenta
dei microfori nelle sue pareti laterali che
consentono il deflusso trasversale di umor
acqueo nello spazio sovracoroideale.
L’impianto di CyPass avviene sotto
visualizzazione gonioscopica dell’angolo
grazie ad un apposito inseritore
precaricato che viene introdotto in camera
anteriore tramite un’incisione corneale
di 1.5 mm. Il corretto posizionamento
nello spazio sovracoroideale può essere
confermato attraverso un esame OCT del
segmento anteriore26.
Un recente studio multicentrico ha
confermato l’efficacia ipotonizzante di
CyPass nel trattamento del glaucoma
primario ad angolo aperto. Nello studio
sono stati coinvolti 65 soggetti che sono
stati sottoposti ad impianto di CyPass.
La IOP media del gruppo in studio
si è ridotta da 24.5±2.8 mmHg a
16.4±5.5 mmHg ad un anno dall’impianto;
anche il numero medio di farmaci
anti-glaucoma si è ridotto da 2.2±1.1 a
1.4±1.327. Un recente studio con follow-
up di 2 anni ha ottenuto risultati similari
(riduzione della IOP del 37% e riduzione del
numero medio di farmaci antiglaucoma da
2.0 a 1.1)28.
I principali eventi avversi correlati
all’impianto di CyPass sono rappresentati
dall’ipotono (13,8%), dalla progressione
dell’opacità lenticolare ad un anno (12,2%),
dalla comparsa di spikes pressori nel
primo mese post-operatorio (10.5%)
e dalla comparsa di infiammazione
persistente (4,4%)27,28. Come per i devices
precedentemente descritti anche in
questo caso sono necessari ulteriori trials
clinici per chiarire il profilo di efficacia e
sicurezza di questo prodotto.
iStent SupraL’iStent Supra (Glaukos, Laguna Hills,
CA, USA) rappresenta l’ultima evoluzione
La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
76Minimally invasive surgery in the treatment of glaucoma: current status and future developments
It is made of a biocompatible polymer
(polyethersulfone) combined with
titanium and presents an overall length
of 4 mm with 0.16-0.17 mm lumen.
Its positioning procedure is the same
as described for Cypass (ab interno
approach with gonioscopic imaging of
the angle).
There are currently few clinical trials on
iStent Supra. In a clinical trial involving
73 patients with a follow-up period of
12 months, implantation of iStent Supra
determined a reduction in mean IOP
from 20.4±4.8 mmHg at baseline to
13.2 mmHg at one year (combined with
administration of Travoprost eye drops).
Regarding safety, no adverse events
worthy of note have occurred29.
XEN Gel Implant XEN Gel Implant (Allergan, Dublin,
Ireland) is a device made of porcine
collagen, 6 mm long, designed to
determine a flow of aqueous humour
from the anterior chamber to the
subconjunctival space without the
need to perform any dissection of the
conjunctiva. The device is available
in three formats that differ in terms of
internal lumen size (45 μm, 63 μm or
140 μm diameter), and is inserted in the
iridocorneal angle under gonioscopic
guidance. It is positioned in the angle
with a dedicated preloaded inserter
that is introduced into the anterior
chamber through a corneal incision of
about 1.5 mm to correctly direct the
device in the subconjunctival space (the
correct positioning is confirmed by the
immediate formation of a conjunctival
filtering bleb).
At present the only clinical trial with a
large patient population was conducted
by Sheybani in 2016, involving 49
patients with primary open-angle
glaucoma and using the XEN implant
with 140 μm lumen. At one year after
dei devices prodotti da Glaukos ma,
diversamente dai suoi predecessori che
presentano come target terapeutico
il trabecolato ed il canale di Schlemm,
questo device mira a mettere in diretta
comunicazione la camera anteriore con lo
spazio sovracoroideale (Fig. 5).
Il device presenta forma cilindrica
ed una leggera curvatura per meglio
adattarsi all’anatomia del bulbo oculare,
è prodotto in un polimero bio-compatibile
(polyethersulfone) associato a titanio e
presenta una lunghezza complessiva di
4 mm con un lume di 0.16-0.17 mm. Il suo
posizionamento è del tutto simile a quello
già descritto per Cypass (approccio ab
interno con visualizzazione gonioscopica
dell’angolo).
Al momento attuale sono presenti pochi
studi clinici che abbiano interessato
iStent Supra. In uno studio clinico che
ha coinvolto 73 pazienti con un follow-
up di 12 mesi l’impianto di iStent Supra
ha determinato una riduzione della IOP
media da 20.4±4.8 mmHg del baseline a
13.2 mmHg ad un anno (in associazione
alla somministrazione di Travoprost
collirio). Per quanto riguarda la sicurezza
non si sono verificati eventi avversi degni
di nota29.
XEN Gel Implant Lo XEN Gel Implant (Allergan, Dublin,
Ireland) è un device in collagene porcino
della lunghezza di 6 mm progettato per
determinare un flusso di umor acqueo
dalla camera anteriore allo spazio
sottocongiuntivale senza la necessità
di eseguire alcuna dissezione della
congiuntiva. Il device è disponibile in
tre formati che differiscono tra loro per
la dimensione del lume interno (45 μm,
63 μm o 140 μm di diametro) e viene
inserito nell’angolo irido-corneale sotto
guida gonioscopica. Il posizionamento
a livello dell’angolo avviene grazie ad un
apposito inseritore precaricato che viene
Year 3 ı Number 2 ı 2017 77La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
implantation of the device, the mean
IOP of the study group diminished from
23.1±4.1 mmHg to 14.7±3.7 mmHg
with a 36.4%percentage reduction in
IOP. Despite a good degree of initial
efficacy, 47% of operated patients
were later submitted to the ‘bleb’
needling procedure within one year from
implantation30.
Sheybani does not report any adverse
event worthy of note from his clinical
trials30. A larger number of clinical trials is
required to clarify the efficacy and safety
profile of this device.
Endocyclophotocoagulation (ECP)This technique envisages the selective
cyclophotocoagulation of variable
portions of the anterior ciliary bodies
by using an endoscopic probe (Endo
Optiks, Little Silver, NJ, USA) connected
to a 810 nm laser diode (IridexOculight,
Mountain View, CA, USA). The
procedure is performed through a
corneal incision of 2.4 mm with direct
endoscopic imaging of the ciliary bodies.
The portion of the ciliary bodies to be
photocoagulated is usually in the range
of 270°-360° but can be customised by
the operator.
In a randomised study that
compared the pressure-reducing
capacity of combined ECP surgery
+ cataract phacoemulsification
introdotto in camera anteriore attraverso
un’incisione corneale di circa 1.5 mm e
che permette di indirizzare correttamente
il device nello spazio sottocongiuntivale
(il corretto posizionamento è confermato
dall’immediata formazione di una bozza
filtrante congiuntivale).
Al momento attuale l’unico studio clinico
con una certa numerosità campionaria
è quello di Sheybani del 2016 che ha
coinvolto 49 pazienti affetti da glaucoma
primario ad angolo aperto e che ha
impiegato lo XEN implant da 140 μm
di lume. Ad un anno dall’impianto del
device la IOP media del gruppo in
studio si è ridotta da 23.1±4.1 mmHg
a 14.7±3.7 mmHg con una riduzione
percentuale della IOP del 36.4%.
Nonostante una buona efficacia iniziale
il 47% dei pazienti operati è stato
successivamente sottoposto a needling
di bozza entro un anno dall’impianto30.
Sheybani nella sua serie clinica non
riporta alcun evento avverso degno
di nota30. Un maggior numero di studi
clinici è necessario per chiarire il profilo
d’efficacia e di sicurezza di questo
device.
Endociclofotocoagulazione (ECP)Questa tecnica prevede la
ciclofotocoagulazione selettiva di porzioni
variabili dei corpi ciliari anteriori tramite
l’impiego di una sonda endoscopica
5Fig.
Fig. 5iStent Supra
(Courtesy of Glaukos)
78Minimally invasive surgery in the treatment of glaucoma: current status and future developments
vs. phacoemulsification surgery
alone, it surfaced that the combined
procedure determines a reduction in
mean IOP from 18.1±3.0 mmHg (with
a mean of 0.4±0.7 drugs in use) to
16.0±3.3 mmHg at 24 months, whereas
phacoemulsification alone determines a
reduction in mean IOP from 18.01±3.0 to
17.3±3.2 mmHg (with a mean of 2.0±1.0
drugs in use)31. A subsequent study
conducted in 2015 with a similar design
reported a reduction in mean IOP in the
ECP + cataract phacoemulsification
group from 17.2±4.8 mmHg to 14.7±3.1
(with a mean of 0.2±0.6 drugs in use) at
three years vs. a reduction in mean IOP
from 17.7±4.4 mmHg to 15.5±3.6 mmHg
(with a mean of 1.3±0.6 drugs in use) in
the control group32.
In terms of safety, none of the two
studies underscored statistically
significant differences between the two
study groups31,32.
DISCUSSIONMIGS techniques are an important
resource for the treatment of glaucoma
as they can determine a significant
reduction in intraocular pressure while
maintaining a very low clinical risk profile.
All these techniques can potentially
revolutionise the current glaucoma
treatment algorithm because, as a result
of their scarce invasiveness and low risk
of adverse events, they can be used to
treat mild-moderate forms of glaucoma
as an alternative to conventional medical
therapy. Early surgical treatment might
improve the management of glaucoma
as it can reduce the events of failed
therapeutic compliance, which are
often recorded with conventional anti-
glaucoma eyedrops.
Besides the low rate of adverse events,
MIGS techniques present additional
advantages, compared to conventional
techniques, including repeatability,
(Endo Optiks, Little Silver, NJ, USA)
collegata ad un diodo laser da 810 nm
(Iridex Oculight, Mountain View, CA, USA).
La procedura viene condotta attraverso
un’incisione corneale di 2.4 mm con
visualizzazione diretta dei corpi ciliari per
via endoscopica. La porzione dei corpi
ciliari da fotocoagulare è solitamente
compresa tra 270°-360° ma può essere
personalizzata dall’operatore.
In uno studio randomizzato che
comparava il potere ipotonizzante
dell’intervento combinato di ECP +
facoemulsificazione di cataratta vs il
solo intervento di facoemulsificazione
è emerso che la procedura combinata
determina una riduzione della IOP media
da 18.1±3.0 mmHg (con una media di
0.4±0.7 farmaci in uso) a 16.0±3.3 mmHg
a 24 mesi mentre il solo intervento di
facoemulsificazione determina una
riduzione della IOP media da 18.01±3.0 a
17.3±3.2 mmHg (con una media di 2.0±1.0
farmaci in uso)31. Un successivo studio del
2015 con simile disegno ha evidenziato
una riduzione della IOP media del gruppo
ECP + facoemulsificazione di cataratta
da 17.2±4.8 mmHg a 14.7±3.1 (con una
media di 0.2±0.6 farmaci in uso) a tre
anni vs una riduzione della IOP media da
17.7±4.4 mmHg a 15.5±3.6 mmHg (con
una media di 1.3±0.6 farmaci in uso) nel
gruppo di controllo32.
Dal punto di vista della sicurezza nessuno
dei due studi ha evidenziato differenze
statisticamente significative tra i due
gruppi in studio31,32.
DISCUSSIONELe tecniche MIGS rappresentano
un’importante risorsa per il trattamento
del glaucoma in quanto sono in grado di
determinare una significativa riduzione
della pressione intraoculare mantenendo
un bassissimo profilo di rischio clinico.
Tutte queste tecniche possono
potenzialmente rivoluzionare l’attuale
Year 3 ı Number 2 ı 2017 79La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
conjunctiva sparing and lack of a filtering
bleb. All these characteristics might
indicate MIGS as candidates for the
new surgical gold standard for mild-
moderate glaucoma therapy. However,
MIGS currently present some important
limitations, and especially the lack of
a long-term follow-up study. Indeed,
all studies at our disposal present a
maximum follow-up period of 24-36
months versus the over ten-year follow-
up periods recorded for conventional
techniques. Moreover, the studies
currently available present very small
patient populations, and there is no
direct comparison with conventional
techniques, such as trabeculectomy and
valve implants.
MIGS are a promising and interesting
instrument for glaucoma therapy but
additional clinical trials conducted
on large patient populations with a
prolonged follow-up period are currently
required to understand their actual
safety and efficacy profile.
algoritmo di trattamento del glaucoma in
quanto, grazie alla loro scarsa invasività ed
al basso rischio di eventi avversi, possono
essere applicate per il trattamento di
forme di glaucoma lieve-moderato in
alternativa alla tradizionale terapia medica.
Un trattamento chirurgico precoce
potrebbe migliorare la gestione della
malattia glaucomatosa in quanto in grado
di ridurre i fenomeni di mancata aderenza
terapeutica che spesso si registrano con i
tradizionali colliri anti-glaucoma.
Oltre al basso tasso di eventi avversi
le tecniche MIGS presentano ulteriori
vantaggi rispetto alle tecniche tradizionali
tra cui la ripetibilità, il risparmio della
congiuntiva e la mancanza di una bozza
filtrante; tutte queste caratteristiche
potrebbero candidare le MIGS a diventare
il nuovo gold standard chirurgico della
terapia del glaucoma lieve-moderato.
Le MIGS allo stato attuale presentano
tuttavia alcune importanti limitazioni tra
cui la principale è la mancanza di un
follow-up a lungo termine. Tutti gli studi
a nostra disposizione presentano infatti
un follow-up massimo di 24-36 mesi a
fronte dei follow-up più che decennali
delle tecniche tradizionali. Gli studi
attualmente disponibili presentano
inoltre una numerosità campionaria
assai esigua e mancano di un confronto
diretto con tecniche tradizionali quali la
trabeculectomia e gli impianti valvolari.
Le MIGS rappresentano un promettente
ed interessante strumento di terapia del
glaucoma ma al momento attuale sono
necessari ulteriori studi clinici con ampia
numerosità campionaria e follow-up
protratto per comprenderne il reale profilo
di sicurezza ed efficacia.
80Minimally invasive surgery in the treatment of glaucoma: current status and future developments
REFERENCES1. Tham YC, Li X, Wong TY, Quigley HA,
Aung T, Cheng CY. Global prevalence
of glaucoma and projections of
glaucoma burden through 2040: a
systematic review and meta-analysis.
Ophthalmolog 2014 Nov;121(11):2081-90
2. Rulli E, Biagioli E, Riva I, et al. Efficacy
and safety of trabeculectomy vs
nonpenetrating surgical procedures:
a systematic review and meta-
analysis. JAMA Ophthalmol 2013
Dec;131(12):1573-82
3. Gedde SJ, Herndon LW, Brandt JD,
et al. Postoperative complications in
the Tube Versus Trabeculectomy (TVT)
study during five years of follow-up.
Am J Ophthalmol 2012 May;153(5):804-
14 e801
4. Minckler D, Baerveldt G, Ramirez
MA, et al. Clinical results with
the Trabectome, a novel surgical
device for treatment of open-angle
glaucoma. Trans Am Ophthalmol Soc
2006;104:40-50
5. Ting JL, Damji KF, Stiles MC,
Trabectome Study G. Ab interno
trabeculectomy: outcomes in
exfoliation versus primary open-angle
glaucoma. J Cataract Refract Surg
2012 Feb;38(2):315-23
6. Minckler D, Mosaed S, Dustin L, Ms
BF, Trabectome Study G. Trabectome
(trabeculectomy-internal approach):
additional experience and extended
follow-up. Trans Am Ophthalmol Soc
2008;106:149-59; discussion 159-60
7. Francis BA, Minckler D, Dustin L, et
al. Combined cataract extraction and
trabeculotomy by the internal approach
for coexisting cataract and open-angle
glaucoma: initial results. J Cataract
Refract Surg 2008 Jul;34(7):1096-103
8. Jordan JF, Wecker T, van Oterendorp
C, et al. Trabectome surgery for
primary and secondary open angle
glaucomas. Graefes Arch Clin Exp
Ophthalmol Dec 2013;251(12):2753-60
9. Spiegel D, Wetzel W, Haffner DS,
Hill RA. Initial clinical experience with
the trabecular micro-bypass stent in
patients with glaucoma. Adv Ther 2007
Jan-Feb;24(1):161-70
10. Spiegel D, Garcia-Feijoo J, Garcia-
Sanchez J, Lamielle H. Coexistent
primary open-angle glaucoma and
cataract: preliminary analysis of
treatment by cataract surgery and the
iStent trabecular micro-bypass stent.
Adv Ther 2008 May;25(5):453-64
11. Fea AM. Phacoemulsification versus
phacoemulsification with micro-bypass
stent implantation in primary open-
angle glaucoma: randomized double-
masked clinical trial. J Cataract Refract
Surg 2010 Mar;36(3):407-12
12. Samuelson TW, Katz LJ, Wells JM,
Duh YJ, Giamporcaro JE, Group
USiS. Randomized evaluation of the
trabecular micro-bypass stent with
phacoemulsification in patients with
glaucoma and cataract. Ophthalmology
2011 Mar;118(3):459-67
13. Craven ER, Katz LJ, Wells JM,
Giamporcaro JE, iStent Study G.
Cataract surgery with trabecular micro-
bypass stent implantation in patients
with mild-to-moderate open-angle
glaucoma and cataract: two-year
follow-up. J Cataract Refract Surg
2012 Aug;38(8):1339-45
14. Arriola-Villalobos P, Martinez-de-la-
Casa JM, Diaz-Valle D, Fernandez-
Perez C, Garcia-Sanchez J, Garcia-
Feijoo J. Combined iStent trabecular
micro-bypass stent implantation and
phacoemulsification for coexistent
open-angle glaucoma and cataract: a
long-term study. Br J Ophthalmol 2012
May;96(5):645-49
15. Fernandez-Barrientos Y, Garcia-Feijoo
J, Martinez-de-la-Casa JM, Pablo LE,
Fernandez-Perez C, Garcia Sanchez J.
Fluorophotometric study of the effect
of the glaukos trabecular microbypass
stent on aqueous humor dynamics.
Invest Ophthalmol Vis Sci 2010
Jul;51(7):3327-32
16. Belovay GW, Naqi A, Chan BJ,
Rateb M, Ahmed, II. Using multiple
trabecular micro-bypass stents in
cataract patients to treat open-angle
glaucoma. J Cataract Refract Surg
2012 Nov;38(11):1911-17
17. Klamann MK, Gonnermann J,
Pahlitzsch M, et al. iStent inject in
Year 3 ı Number 2 ı 2017 81La chirurgia mininvasiva nella terapia del glaucoma: stato attuale e futuri sviluppi
phakic open angle glaucoma. Graefes
Arch Clin Exp Ophthalmol 2015
Jun;253(6):941-47
18. Grover DS, Godfrey DG, Smith
O, Feuer WJ, Montes de Oca I,
Fellman RL. Gonioscopy-assisted
transluminal trabeculotomy, ab interno
trabeculotomy: technique report and
preliminary results. Ophthalmology
2014 Apr;121(4):855-61
19. Grover DS, Godfrey DG, Smith O, Shi
W, Feuer WJ, Fellman RL. Outcomes
of Gonioscopy-assisted Transluminal
Trabeculotomy (GATT) in Eyes With
Prior Incisional Glaucoma Surgery. J
Glaucoma 2017 Jan;26(1):41-45
20. Berlin MS, Rajacich G, Duffy M,
Grundfest W, Goldenberg T. Excimer
laser photoablation in glaucoma
filtering surgery. Am J Ophthalmol
1987 May 15;103(5):713-14
21. Babighian S, Caretti L, Tavolato
M, Cian R, Galan A. Excimer laser
trabeculotomy vs 180 degrees
selective laser trabeculoplasty in
primary open-angle glaucoma. A
2-year randomized, controlled trial.
Eye (Lond) 2010 Apr;24(4):632-38
22. Toteberg-Harms M, Hanson JV, Funk
J. Cataract surgery combined with
excimer laser trabeculotomy to lower
intraocular pressure: effectiveness
dependent on preoperative IOP. BMC
Ophthalmol 2013 Jun 24;13:24
23. Johnstone MA, Grant WG. Pressure-
dependent changes in structures of
the aqueous outflow system of human
and monkey eyes. Am J Ophthalmol
1973 Mar;75(3):365-83
24. Pfeiffer N, Garcia-Feijoo J, Martinez-
de-la-Casa JM, et al. A Randomized
Trial of a Schlemm's Canal Microstent
with Phacoemulsification for Reducing
Intraocular Pressure in Open-Angle
Glaucoma. Ophthalmology 2015
Jul;122(7):1283-93
25. Gandolfi SA, Ungaro N, Ghirardini
S, Tardini MG, Mora P. Comparison
of Surgical Outcomes between
Canaloplasty and Schlemm's Canal
Scaffold at 24 Months' Follow-Up.
J Ophthalmol 2016;2016:3410469
26. Saheb H, Ianchulev T, Ahmed, II.
Optical coherence tomography of the
suprachoroid after CyPass Micro-Stent
implantation for the treatment of open-
angle glaucoma. Br J Ophthalmol 2014
Jan;98(1):19-23
27. Garcia-Feijoo J, Rau M, Grisanti S, et
al. Supraciliary Micro-stent Implantation
for Open-Angle Glaucoma Failing
Topical Therapy: 1-Year Results of a
Multicenter Study. Am J Ophthalmol
2015 Jun;159(6):1075-81 e1071
28. Grisanti S, Margolina E, Hoeh H, et
al. [Supraciliary microstent for open-
angle glaucoma: clinical results of
a prospective multicenter study].
Ophthalmologe 2014 Jun;111(6):548-52
29. Gigon A, Shaarawy T. The
Suprachoroidal Route in Glaucoma
Surgery. J Curr Glaucoma Pract 2016
Jan-Apr;10(1):13-20
30. Sheybani A, Dick HB, Ahmed, II. Early
Clinical Results of a Novel Ab Interno
Gel Stent for the Surgical Treatment of
Open-angle Glaucoma. J Glaucoma
2016 Jul;25(7):e691-96
31. Francis BA, Berke SJ, Dustin
L, Noecker R. Endoscopic
cyclophotocoagulation combined
with phacoemulsification versus
phacoemulsification alone in medically
controlled glaucoma. J Cataract
Refract Surg 2014 Aug;40(8):1313-21
32. Siegel MJ, Boling WS, Faridi
OS, et al. Combined endoscopic
cyclophotocoagulation and
phacoemulsification versus
phacoemulsification alone in the
treatment of mild to moderate
glaucoma. Clin Exp Ophthalmol 2015
Aug;43(6):531-39
82
FLACONE DA 5 mlRICETTA RIPETIBILEFASCIA C
PREZZO AL PUBBLICO 7,50G
Ofloxacina 3 mg/mlVISUAB
ANTIBATTERICO PER LE INFEZIONI OCULARI
DAT
A D
EPO
SITO
AIF
A: 2
2-03
-201
7 - C
OD
.PRO
D. 2
2031
7
FRF
1. DENOMINAZIONE DEL MEDICINALEVisuAb, 3 mg/ml collirio, soluzione
2. COMPOSITIONE QUALITATIVA E QUANTITATIVA
1 ml di collirio contiene 3 mg di ofloxacina.1 goccia contiene approssimativamente 0,10 mg ofloxacina.Altri componenti: Benzalconio cloruro 0,025 mg/ml
Per l’elenco completo degli eccipienti, vedere paragrafo 6.1.
3. FORMA FARMACEUTICA
Collirio Soluzione.Soluzione chiara, di un pallido colore giallo/verde.
4. INFORMAZIONI CLINICHE
4.1 Indicazioni terapeuticheTrattamento topico delle infezioni oculari esterne come congiuntiviti batteriche e cheratiti, negli adulti e nei bambini, causati da organismi sensibili all’ofloxacina.Si devono tenere in considerazione le linee guida ufficiali sull’uso appropriato degli agenti antibatterici.
4.2 Posologia e modo di somministrazione PosologiaInstillare una goccia di VisuAb nel sacco congiuntivale dell’occhio affetto ogni 2/4 ore per I primi due giorni, successivamente una goccia 4 volte al giorno.La durata del trattamento non deve superare i 14 giorni.Se si sta utilizzando un altro agente topico, VisuAb deve essere somministrato ad almeno 15 minuti di distanza dall’altro agente. Gli unguenti dovrebbero sempre essere applicati per ultimi.
Popolazione pediatrica Non sono necessari aggiustamenti della dose.
Popolazione anziana Non sono necessari aggiustamenti della dose (vedere paragrafo 4.4).
4.3 ControindicazioniIpersensibilità all’ofloxacina, ad altri chinoloni o ad uno qualsiasi degli eccipienti elencati al paragrafo 6.1.
4.4 Avvertenze speciali e precauzioni d’impiegoVisuAb non deve essere iniettato.
La sicurezza e l’efficacia nei bambini al di sotto di un anno di età non sono state stabilite.
Se si manifesta una reazione allergica, interrompere il farmaco.
Durante il trattamento con colliri contenenti ofloxacina si deve evitare un’esposizione ecces-siva alla luce del sole e ai raggi ultravioletti (ad es. lampade abbronzanti, solarium ecc.) a causa della potenziale fotosensibilità.
Durante il trattamento con ofloxacina per via oftalmica sono stati segnalati precipitati cor-neali, tuttavia non è stata stabilita una relazione causale.
Si deve considerare che l’uso di VisuAb collirio, a causa del passaggio rinofaringeo, può contribuire al verificarsi e al diffondersi di resistenza batterica all’ofloxacina. Come per altri antibiotici, l’uso prolungato può determinare la crescita di organismi resistenti.Se l’infezione peggiora, o se non si notano miglioramenti entro un ragionevole periodo di tempo, interrompere l’uso di VisuAb e passare ad una terapia alternativa.
Usare VisuAb con cautela nei pazienti che hanno manifestato sensibilità ad altri agenti antibatterici chinolonici.
Sono state segnalate reazioni di ipersensibilità gravi e occasionalmente fatali (anafilatti-che/anafilattoidi), alcune a seguito della prima dose, in pazienti in trattamento con chi-noloni per via sistemica, compresa oloxacina. Alcune reazioni erano accompagnate da collasso cardiovascolare, perdità di conoscenza, angioedema (incluso edema laringeo, faringeo o facciale), ostruzione delle vie aeree, dispnea, orticaria e prurito. I dati sono molto limitati per stabilire efficacia e sicurezza di ofloxacina collirio 0,3% nel trattamento delle congiuntiviti nei neonati.
L’uso dell’ofloxacina collirio nei neonati con oftalmia dei neonati causata da Neisseria gonorrhoeae o da Chlamydia trachomatis non è raccomandato poichè non è stato valutato in questi pazienti.
Uso in pazienti anziani e nella popolazione pediatrica: non sono disponibili dati compara-tivi con dosi topiche negli anziani o nei pazienti pediatrici rispetto ad altre classi di età ma, considerando il minimo assorbimento sistemico, può essere utilizzata la stessa posologia.
Pubblicazioni cliniche e non cliniche hanno segnalato il verificarsi di perforazioni della cor-nea in pazienti con difetti presistenti dell’epitelio corneale o con ulcera corneale, quando trattati con antibiotici fluorochinolonici per via topica. Tuttavia, in molti casi erano presenti fattori confondenti significativi, inclusa l’età avanzata, la presenza di ampie ulcere, con-comitanti condizioni oculari (ad es. occhio secco grave), malattie infiammatorie sistemicha (ad es. artrite reumatoide) e concomitante uso di steroidi oculari o farmaci antinfiammatori non steroidei. Ciònonostante è necessario prestare cautela riguardo il rischio di perfora-zione corneale quando si utilizza il prodotto per trattare pazienti con difetti dell’epitelio corneale o ulcere corneali.
VisuAb contiene il conservante benzalconio cloruro, che può causare irritazione agli occhi e può essere assorbito dalle lenti a contatto morbide e scolorirle. L’uso di lenti a contatto non è raccomandato in pazienti in trattamento per infezioni dell’occhio.
4.5 Interazioni con altri medicinali e altre forme di interazione È stato dimostrato che la somministrazione sistemica di alcuni chinoloni inibisce la clearan-ce metabolica della caffeina e della teofillina. Studi di interazione tra farmaci condotti con ofloxacina somministrata per via sistemica hanno dimostrato che la clearance metabolica della caffeina e della teofillina non è significativamente influenzata dall’ofloxacina.
Sebbene siano stati riportati casi di aumentata prevalenza di tossicità al livello del SNC con la somministrazione sistemica di fluorochinoloni in concomitanza con antinfiammatori non steroidei (FANS), questo non è stato evidenziato negli studi condotti con FANS e ofloxacina somministrati per via sistemica.
4.6 Fertilità, gravidanza e allattamento. Gravidanza:Non sosno stati condotti studi adeguati e ben controllati su donne in gravidanza. Poiché è stato dimostrato che i chinolonici sistemici causano artropatia negli animali immaturi, si raccomanda di non somministrare ofloxacina nelle donne in gravidanza (vedere paragrafo 5.3).
Allattamento: Poichè l’ofloxacina e gli altri chinoloni assunti per via sistemica sono escreti nel latte ma-terno con un potenziale rischio per i lattanti, si deve decidere se sospendere l’allattamento o l’assunzione del farmaco durante l’allattamento, considerando l’importanza del farmaco per la madre.
Fertilità: Ofloxacina non influenza la fertilità nei ratti (vedere paragrafo 5.3).
4.7 Effetti sulla capacità di guidare veicoli e sull’uso di macchinariNon sono stati condotti studi sulla capacità di guidare veicoli e di utilizzare macchinari. Può verificarsi un momentaneo offuscamento della vista a seguito dell’instillazione del colli-rio. Non guidi veicoli o manovri macchine pericolose se la sua vista non è a fuoco.
4.8 Effetti indesideratiSistemiciLe reazioni avverse grave che si manifestano dopo l’uso di ofloxacina per via sistemica sono rare e molti dei sintomi sono reversibili. Poiché una piccola quantità di ofloxacina è assorbita per via sistemica dopo la somministrazione topica, si possono verificare gli stessi effetti indesiderati segnalati con la via di somministrazione sistemica.
Per la classificazione della frequenza degli eventi avversi sono state utilizzate le seguenti categorie: Molto comune ( 1/10)Comune ( 1/100, <1/10)Non Comune ( 1/1.000, <1/100)Raro ( 1/10.000, <1/1.000)Molto raro (<1/10.000)Non nota (la frequenza non può essere definita sulla base dei dati disponibili)
Disturbi del sistema immunitarioNon Nota: reazioni di ipersensibilità inclusi segni e sintomi di allergia all’ occhio (come ad esempio prurito dell’occhio e delle palpebre), reazione anafilattica (come ad esempio angioedema, dispnea, reazione anafillatica /shock, edema orofaringeo e della lingua), dermatite allergica.
Patologie del sistema nervosoNon nota: Capogiro
Patologie dell’occhioComune: Irritazione dell’occhio; Fastidio oculareNon nota: Cheratite; Congiuntivite; Visione offuscata; Fotofobia; Edema oculare; sensa-zione di corpo estraneo nell’occhio; aumento della lacrimazione; occhio secco; dolore oculare; iperemia oculare;, edema periorbitale (incluso edema palpebrale).
Patologie gastrointestinaliNon nota: Nausea
Patologie della cute e del tessuto sottocutaneoNon noto: Sindrome di Stevens-Johnson, necrolisi tossica epidermica, edema del viso
Segnalazione delle reazioni avverse sospetteLa segnalazione delle reazioni avverse sospette che si verificano dopo l’autorizzazione del medicinale è importante, in quanto permette un monitoraggio continuo del rapporto beneficio/rischio del medicinale. Agli operatori sanitari è richiesto di segnalare qualsiasi reazione avversa sospetta tramite il sistema nazionale di segnalazione all’indirizzo www.agenziafarmaco.gov.it/it/responsabili.
4.9 SovradosaggioNon sono stati segnalati casi di sovradosaggio. In caso di sovradosaggio topico, lavare gli occhi con acqua. Se si verificano effetti indesiderati sistemici a seguito dell’uso non corretto o di un overdose accidentale il trattamento deve essere sintomatico.
5. PROPRIETÀ FARMACOLOGICHE
5.1 Proprietà farmacodinamicheCategoria farmacoterapeutica: Antiinfettivi, fluorochinoloni, codice ATC: S01AE01
Meccanismo d’azioneL’Ofloxacina è un derivato dell’acido chinolonico e inibisce la DNA girasi batterica con effetto battericida.
Meccanismo di resistenzaLo sviluppo della resistenza ai fluorichinoloni, da parte di batteri sensibili, si verifica gene-ralmente a seguito di mutazione del gene gyrA che codifica la subunità A della DNA girasi.In aggiunta, l’efflusso attivo è responsabile di un basso livello di resistenza che può agire come primo step nelle selezione della resistenza. La resistenza può insorgere attraverso un processo multistep con una serie di mutazioni successive che producono progressivamente un livello più alto di reisstenza in modo graduale. Le specie con sensibilità borderline possono diventare resistenti con un singolo step di mutazione. La resistenza plasmide mediate è stata scoperta in E. coli e Klebsiella.I batteri resistenti ad un fluorochinolone mostrano cross resistenza ad altri membri della classe dei chinoloni.
BreakpointsNello studio di resistenza menzionato di seguito batteri isolati erano classificati come su-scettibili o resistenti in base alle raccomandazioni dell’European Committee of Antimicro-bial Susceptibility Testing (EUCAST). Dove stabilito è stato utilizzato l’EUCAST epidemiolo-gical cut-off values (ECOFF), altrimenti è stato applicato l’EUCAST clinical breakpoints per gli agenti antibatterici somministrati per via sistemica:
suscettibile resistente ECOFFStaphylococcus spp. “ 1 mg/l > 1 mg/lStreptococcus pneumoniae “ 0,125 mg/l > 4 mg/l
“ 0,5 mg/l > 0,5 mg/lMoraxella catarrhalis > 0,5 mg/lEnterobacteriaceae “ 0,5 mg/l > 1 mg/lAcintetobacter spp. ND NDPseudomonas aeruginosa ND NDEnterococcus faecalis ND NDEscherichia coli > 1 mg/lKlebsiella pneumoniae > 1 mg/lKlebsiella spp. > 1 mg/lSerratia spp. “ 0,5 mg/l > 1 mg/l “ 1 mg/l
RIASSUNTO DELLE CARATTERISTICHE DEL PRODOTTO
Spettro Antibatterico Lo spettro antibatterico dell’ofloxacina include organismi anaerobi obbligati, organismi anaerobi facoltativi, organismi aerobi e altri tipi di organismi come ad esempio la clami-dia. Si deve presumere che l’ofloxacina sia assorbita dopo somministrazione locale senza causare cambiamenti clinici o patologici.
La prevalenza di resistenza acquisita può variare localmente o nel corso del tempo. Per-tanto, è importante avere l’informazione locale relativa alla resistenza, soprattutto per un adeguato trattamento di infezioni gravi. In caso di dubbio relativamente alla prevalenza di resistenza locale all’oflxacina, deve essere consultato un esperto. Particolarmente in caso di infezioni gravi o in caso di mancata efficacia deve essere con-dotta una diagnosi microbiologica con individuazione dell’agente eziologico della patolo-gia e della sua sensibilità all’ofloxacina.
Nella tabella sottostante sono elencati i dati di sensibilità raccolti in uno studio sulla resisten-za batterica con 1391 isolati di origine oculare (principalmente con un tampone esterno) da 31 centri tedeschi. I microrganismi aerobi elencati danno un’idea rappresentativa della causa delle infezioni batteriche in Germania. Si deve considerare che la distribuzione delle frequenze dei patogeni oftalmologicamente rilevanti non è identica negli altri paesi, ma simile. Per questo motive I patogeni menzionati di seguito saranno la causa più frequente di infezioni batteriche anche negli altri paesi.
5.2 Proprietà farmacocineticheIn uno studio su volontari sani, le concentrazioni medie di ofloxacina riscontrata nel film lacrimale dopo 4 ore dalla somministrazione topica (9.2 μg/g) era più alta di 2 μg/ml, la concentrazione minima di ofloxacina necessaria per inibire il 90% dei ceppi batterici oculari (MIC90) in-vitro. Le concentrazioni massime di ofloxacina nel siero dopo 10 giorni di somministrazione topica era di circa 1000 volte più bassa di quella riportata dopo la somministrazione orale di una dose standard di ofloxacina e non sono stati osservati effetti indesiderati sistemici imputabili alla somministrazione topica di ofloxacina.
5.3 Dati preclinici di sicurezza.A dosi cliniche rilevanti somministrate per via oculare questo prodotto non ha dato pro-blemi di tossicità nell’uomo. Test di induzione di mutazione genica grave, sia in vitro che in vivo sono risultati negative. Non ci sono studi a lungo termine di carcinogenicità negli animali. Non ci sono prove di effetti catarattogenici o co carattogenici.
L’ofloxacina non influenza la fertilità, o lo sviluppo peri e post natale e non è teratogena. Non è stato osservato nessun cambiamento degenerativo nelle articolazioni degli anima-li dopo somministrazione sistemica. Il danno della cartilagine articolare era dipendente dall’età e dal dosaggio (più giovane era l’animale maggiore era l’effetto). Quando som-ministrata per via sistemica, l’ofloxacina ha proprietà neurotossiche e induce anormalità reversibili nei test ad alto dosaggio. Come altri chinoloni, l’ofloxacina è fototossica negli animali quando utilizzata per via sistemica nel range terapeutico dell’uomo.
6. INFORMAZIONI FARMACEUTICHE
6.1 Elenco degli eccipientiBenzalconio cloruroSodio cloruroAcido cloridrico e idrossido di sodio (per l’aggiustamento del pH)Acqua per preparazioni iniettabili
6.2 IncompatibilitàNessuna.
6.3 Periodo di validità2 anni.Dopo la prima apertura VisuAb non deve essere utilizzato per più di 4 settimane.
6.4 Precauzioni particolari per la conservazioneNon conservare a temperature superiore ai 25°C.Conservare il contenitore nella scatola per proteggere il prodotto dalla luce.In caso di scolorimento giallo/verdastro della soluzione il prodotto deve essere eliminato.
6.5 Natura e contenuto del contenitoreVisuAb è fornito in un flacone contagocce in polietilene a bassa densità (LDPE) con tappo a vite (HDPE).Ciascun flacone contiene 5 ml di VisuAb.
6.6 Precauzioni particolari per lo smaltimento e la manipolazioneNessuna istruzione particolare.
7. TITOLARE ALL’IMMISSIONE IN COMMERCIOVISUfarma S.p.A.Via Canino, 2100191 - RomaTel..: +39 (06) 3630-6818Fax: +39 (06) 3630-6842e-mail: [email protected]
8. AUTORIZZAIZONE ALL’IMMISSIONE IN COMMERCIO044623015 - “ 3 MG/ML COLLIRIO, SOLUZIONE “ 1 FLACONE DA 5 ML IN LDPE CON APPLICATORE CONTAGOCCE
9. DATA DI PRIMA AUTORIZZAZIONE/RINNOVO DELL’AUTORIZZAZIONEData di prima autorizzazione:26/08/2016
10. DATA DI REVISIONE DEL TESTO 15/09/2016
Specie normalmente sensibili (Tasso di resistenza “10 %)
Microorganismi Aerobici gram-positivi
Staphylococcus aureus (MSSA)
Microorganismi Aerobici gram-negativi
Enterobacteriaceae (Escherichia coli, Proteus mirabilis, Klebsiella oxytoca, Serratia marcescens, Enterobacter cloacae and Klebsiella pneumoniae)
Acinetobacter baumannii
Moraxella catarrhalis
Specie in cui la resistenza acquisita può causare problemi nel trattamento (tasso di resistenza >10 %)
Microorganismi Aerobici gram-positivi
Staphylococcus aureus (MRSA)
Streptococcus pneumoniae
Coagulase-negative staphylococci
Enterococcus
Microorganismi Aerobici gram-negativi
Pseudomonas aeruginosa
Moraxella catarrhalis
Year 3 ı Number 2 ı 2017 85
CORRESPONDING AUTHORAlberto Salicone
P.O. San Leonardo
Struttura Complessa
di Oculistica
Viale Europa,
80053 Castellammare
di Stabia (NA)
KEY WORDSGlaucoma, Pachymetry,
Perimetry
PAROLE CHIAVEGlaucoma, Pachimetria,
Perimetria
RELATIONSHIP BETWEEN CORNEAL PACHYMETRY AND PERIMETER DAMAGE EVALUATED WITH GLAUCOMA STAGING SYSTEM
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
Lorenzo Motta, Alberto Salicone, Giancarlo Arienzo, Gennaro Sepe, Chiara De Martino, Arturo Napoli, Mario Salvatore MottaP.O. San Leonardo - Struttura Complessa di OculisticaViale Europa, 80053 Castellammare di Stabia (NA)
RIASSUNTOObiettivi: valutare l'associazione tra
pachimetria corneale e progressione del
campo visivo in pazienti affetti da glaucoma
primario ad angolo aperto (POAG).
Procedure di base: analisi
retrospettiva, studio comparativo.
Il Glaucoma Staging System (GSS)
e i dati pachimetrici appartenenti agli
occhi destri di 168 pazienti con POAG
e pressione intraoculare controllata
farmacologicamente (IOP <20 mmHg)
sono stati analizzati retrospettivamente.
I criteri di esclusione sono stati: pregressi
trattamenti chirurgici o parachirurgici
oculari ed un periodo di follow-up inferiore
a 4 anni. Lo spessore corneale centrale
(CCT) è stato determinato mediante
pachimetria ad ultrasuoni.
I pazienti sono stati divisi in due gruppi
(gruppo 1 <540 micron; gruppo
2> o = 540 micron). Per ogni occhio lo
stadio al basale e al follow-up finale sono
stati valutati utilizzando il GSS. Il test
statistico del Chi-quadrato ( ²) è stato
utilizzato per analizzare i dati.
Risultati: 89 femmine (52,3%) e 79 maschi
(47,7%) sono stati inclusi nel nostro studio.
L'età media era 58,8 ± 8,7 anni (range
42-79). Il follow-up medio considerando la
totalità dei pazienti è stato 4,6± 0,5 anni.
La CCT media era 526,7 ± 10,4 micron
nel gruppo 1 (84 pazienti) e 576,2 ± 32,7
micron nel gruppo 2 (84 pazienti).
Nel gruppo 1 la stadiazione glaucoma al
ABSTRACTScope: to evaluate the association
between corneal pachymetry and
visual field progression in patients
with primary open-angle glaucoma
(POAG).
Basic procedures: retrospective,
comparative case series. The
Glaucoma Staging System (GSS)
and pachymetric data from the right
eyes of 168 patients with POAG
and medically controlled intraocular
pressure (IOP < 20 mmHg) were
retrospectively analyzed. Exclusion
criteria were laser or surgical ocular
treatments and a follow-up period
inferior to 4 years. Central corneal
thickness (CCT) was determined
by ultrasound pachymetry. The
patients were split in two groups
(group 1 < 540 micron; group 2 >
or =540 micron). For each eye the
stage of defect at baseline and at
final follow-up were assessed using
GSS. Statistical test of ² was used to
analyze data.
Results: 89 females (52.3%) and 79
males (47.7%) were included in our
study. The mean age was 58.8 ± 8.7
years (range 42-79). Considering
the total number of patients, mean
follow-up period was 4,6± 0,5 years.
Mean CCT was 526.7± 10.4 microns
in group 1 (84 patients) and 576.2 ±
32.7 microns in group 2 (84 patients).
86
In group 1 baseline glaucoma stage
was the following: 66 patients (78.5%)
at GSS 1 and 18 patients (21.5%) at
GSS 2. In group 2, 70 patients (83.3%)
were at GSS 1 and 14 patients (16.7%)
at GSS 2. There was no significant
difference for initial glaucoma stage
between the two groups (p=0.3).
At the final follow-up 39 patients
(46.4%) of group 1 were stable while
GSS worsened in 45 patients (53.6%);
in group 2 GSS had no progression in
64 patients (76.1%), while it progressed
in 20 patients (23.9%). There was a
statistically significant difference for
final GSS stage which was worse in
group 1 than in group 2 (p<0.001).
Considering all eyes, at the final
follow-up, 103 patients (61.3%) had
stable GSS parameters, 65 patients
(38.7%) progressed in their GSS stage.
Among these 65 patients, 45 cases
(69.2%) belonged to group 1 and only
20 (30.8%) to group 2. Eyes with a final
GSS3 were 7/84 (8,4%) in group 1 and
5/84 (6,1%) in group 2 (p=0.6).
Conclusions: in our study CCT
did not significantly correlate with
glaucomatous damage at presentation.
In medically controlled primary
open-angle glaucoma, visual field
progression evaluated with GSS was
significantly associated with thinner
CCT. In more advanced glaucoma
stages CCT might not play a role.
INTRODUCTION Central corneal thickness (CCT)
assessment is important in glaucoma
management for several reasons.
CCT is a proven strong risk factor for
conversion from ocular hypertension
(OHT) to primary open-angle glaucoma
(POAG)1. CCT can have a significant
effect on intraocular pressure
(IOP) measured with Goldmann’s
applanation tonometry2,3,4, and
basale era la seguente: 66 pazienti (78,5%)
al GSS 1 e 18 pazienti (21,5%) al GSS 2.
Nel gruppo 2, 70 pazienti (83,3%) erano al
GSS 1 e 14 pazienti (16,7% ) al GSS 2. Non
vi era differenza statisticamente significativa
per quanto riguarda lo stadio GSS iniziale
tra i due gruppi (p = 0.3). Al follow-up finale,
39 pazienti (46,4%) del gruppo 1 avevano
mantenuto un GSS stabile, mentre il GSS
era peggiorato in 45 pazienti (53,6%);
nel gruppo 2 il GSS non aveva avuto
progressione in 64 pazienti (76,1%), mentre
era progredito in 20 pazienti (23,9%). Vi era
una differenza statisticamente significativa
per la fase finale del GSS nel senso
che quest’ultima risultava peggiore nel
gruppo 1 rispetto al gruppo 2 (p <0.001).
Considerando tutti gli occhi, al follow-
up finale, 103 pazienti (61,3%) avevano
parametri GSS stabili, 65 pazienti (38,7%)
erano peggiorati. Tra questi 65 pazienti,
45 casi (69,2%) appartenevano al gruppo
1 e solo 20 (30,8%) al gruppo 2. Gli occhi
con un GSS3 finale erano 7/84 (8,4%)
nel gruppo 1 e 5/84 (6,1%) nel gruppo 2
(p=0.6).
Conclusioni: nel nostro studio la CCT non
era risultata correlata in modo significativo
con il danno glaucomatoso al momento
della presentazione.
Nel glaucoma primario ad angolo aperto
(POAG) farmacologicamente controllato, la
progressione del campo visivo valutata con
il GSS era significativamente associata con
una CCT più bassa.
In caso di stadi di glaucoma più avanzati la
CCT potrebbe non avere alcuna influenza.
INTRODUZIONELa valutazione dello spessore corneale
centrale (CCT) è importante nella gestione
del glaucoma per diversi motivi. La CCT
ha dimostrato di essere un forte fattore di
rischio per la conversione da ipertensione
oculare (OHT) a glaucoma primario
ad angolo aperto (POAG)1. La CCT
può influenzare in modo significativo la
Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
Year 3 ı Number 2 ı 2017 87
Fig. 1 Graphic GSS
Grafico GSS
1Fig.
is also useful to define glaucoma
therapy. Many studies have reported
that progression of the visual field in
patients with POAG was significantly
associated with a thinner CCT5,6,7,8.
Standard automated perimetry (SAP)
is still the accepted technique to
quantify glaucoma-related damage.
The Glaucoma Staging System (GSS)
was introduced in 1996 to provide
standardised classification of perimeter
results. It is based on two main global
perimeter indices (Mean Deviation
[MD] and Corrected Pattern Standard
Deviation [CPSD], or Corrected
Loss Variance [CLV]) that are placed
in a Cartesian graph with intervals
decreasing from left to right and from
top to bottom9 (Fig. 1). The scope of our
study was to assess the association
between corneal pachymetry and
visual field progression in patients with
pharmacologically compensated POAG.
METHODClinical records of patients reporting
to our clinic in the period 2008-2010
were subjected to retrospective
analysis. 168 patients met the inclusion
criteria of POAG with target IOP <20
misurazione della pressione intraoculare
(IOP) ottenuta mediante tonometria
ad applanazione di Goldmann2,3,4. ed
è anche utile per stabilire la terapia del
glaucoma. In molti studi la progressione
del campo visivo in pazienti con POAG
era significativamente associata con
una CCT più sottile5,6,7,8. La perimetria
standard automatizzata (SAP) è ancora la
tecnica accettata per quantificare il danno
glaucomatoso. Nel 1996, il Glaucoma
Staging System (GSS) è stato introdotto
con l'intento di fornire una classificazione
standardizzata dei risultati perimetrici. Si
basa su due principali indici perimetrici
globali (Deviazione media [MD] e Deviazione
Standard Pattern Corretta [CPSD], o
Perdita di Varianza Corretta [CLV]), disposti
su di un grafico cartesiano, in cui gli intervalli
diminuiscono andando da sinistra a destra
e dall'alto verso il basso9. (Fig. 1) Lo scopo
del nostro studio è stato quello di valutare
l'associazione tra pachimetria corneale e
progressione del campo visivo nei pazienti
con POAG in compenso farmacologico.
METODOLOGIALe cartelle cliniche dei pazienti afferiti al
nostro ambulatorio tra il 2008 e il 2010
sono state analizzate retrospettivamente.
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
88Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
168 pazienti rispettavano i criteri di
inclusione: POAG con IOP target
<20 mmHg ottenuta farmacologicamente,
follow-up compreso tra 4 e 5 anni
ed anamnesi negativa per pregressi
trattamenti chirurgici o parachirurgici
oculari. I dati provenienti dal Glaucoma
Staging System (GSS) e i valori di CCT
sono stati registrati solo per l’occhio
destro di ciascun paziente; infatti, per
quelle condizioni patologiche egualmente
probabili in entrambi gli occhi, le analisi
basate sulla selezione di un solo occhio
oppure sulla selezione randomizzata
risultano statisticamente equivalenti.
La CCT è stata misurata con pachimetria
ad ultrasuoni. I pazienti sono stati divisi
in modo che 84 occhi avevano una
pachimetria <540 micron (gruppo 1) e 84
occhi con pachimetria> 0 = 540 micron
(Gruppo 2). Per ogni occhio sono stati
valutati lo stadio GSS al basale e al
follow-up finale. Le differenze nello stadio
GSS alla prima e alla visita finale sono
state valutate utilizzando il test del Chi-
quadrato ( ²). La significatività statistica è
stata stabilita al valore p <0.05.
RISULTATII dati epidemiologici sono illustrati nella
tabella 1. Vi erano 89 femmine (52,3%) e
79 maschi. L'età media dei pazienti era
58,8 ± 8,7 anni (range 42-79). Il follow-up
medio considerando la totalità dei pazienti
è stato 4,6± 0,5 anni. La CCT media
era 526,7 ± 10,4 micron per il gruppo
1 (84 pazienti) e 576,2 ± 32,7 micron
per il gruppo 2 (84 pazienti). Nel gruppo
1 la stadiazione glaucoma è stata la
seguente: 66 pazienti (78,5%) al GSS 1 e
18 pazienti (21,5%) al GSS 2. Nel gruppo
2, 70 pazienti (83,3%) erano al GSS 1 e
14 pazienti (16,7% ) al GSS 2. Non vi era
significatività statistica nella differenza di
stadiazione glaucoma al basale tra i due
gruppi (p = 0.3). I risultati sono mostrati
mmHg obtained pharmacologically, 4
to 5-year follow-up and negative history
of past ocular surgical or parasurgical
treatments. Glaucoma Staging System
(GSS) data and CCT values were only
recorded for the right eye of each patient.
In fact, for pathological conditions,
whose onset is equally probable in both
eyes, analyses based on the selection of
only one eye or on randomised selection
are statistically equivalent. CCT was
measured with ultrasound pachymetry.
Patients were divided into 2 groups with
84 eyes with pachymetry <540 micron
(group 1) and 84 eyes with pachymetry
>0 = 540 micron (Group 2). GSS stage
at baseline and at the final follow-up visit
was assessed for every eye. Differences
in GSS stage at the first and at the final
visit were assessed using the Chi square
test ( ²). Statistical significance was set at
p <0.05.
RESULTSEpidemiological data is illustrated
in Table 1. The study enrolled 89
females (52.3%) and 79 males with
mean age 58.8 ± 8.7 years (range
42-79). Considering the total number
of patients, the mean follow-up period
was 4.6 ± 0.5 years. The mean CCT
was 526.7 ± 10.4 micron for group
1 (84 patients) and 576.2 ± 32.7
micron for group 2 (84 patients). In
group 1, glaucoma staging recorded
66 patients (78.5%) at GSS 1 and 18
patients (21.5%) at GSS 2. In group
2, 70 patients (83.3%) were at GSS
1 and 14 patients (16.7%) at GSS 2.
There was no statistical significance
in the difference in glaucoma staging
at baseline between the two groups
(p = 0.3). The results are schematically
presented in Table 1. At the final follow-
up visit, 39 patients (46.4%) in group 1
were stable, whereas the GSS stage
Year 3 ı Number 2 ı 2017 89
schematicamente nella tabella 1: al
follow-up finale 39 pazienti (46,4%) del
gruppo 1 erano rimasti stabili, mentre lo
stadio GSS era peggiorato in 45 pazienti
(53,6%); nel gruppo 2 lo stadio GSS non
aveva evidenziato progressione in 64
pazienti (76,1%), mentre era progredito
in 20 pazienti (23,9%). Al follow-up finale
c'era una differenza statisticamente
significativa per la progressione dello
stadio GSS tra il gruppo 1 e gruppo 2
(p <0.001). Considerando tutti gli occhi,
al follow-up finale, 103 pazienti (61,3%)
avevano parametri GSS stazionari,
65 pazienti (38,7%) mostravano un
peggioramento della stadiazione GSS.
Tra questi 65 pazienti, 45 casi (69,2%)
appartenevano al gruppo 1 e solo 20
(30,8%) al gruppo 2. Gli occhi con un GSS 3
finale erano 7/84 (8,4%) nel gruppo 1 e 5/84
(6,1%) nel gruppo 2 (p=0.6) (Fig. 2).
DISCUSSIONELa CCT è universalmente accettata come
un parametro importante per la valutazione
had worsened in 45 patients (53.6%);
in group 2, the GSS stage presented
no progression in 64 patients (76.1%),
whereas it had progressed in 20
patients (23.9%). The final follow-up
visit found a statistically significant
difference in GSS stage progression
between group 1 and group 2 (p
<0.001). Considering all the eyes, at
the final follow-up visit, 103 patients
(61.3%) had stable GSS parameters,
and 65 patients (38.7%) presented
a worsened GSS stage. Of these 65
patients, 45 cases (69.2%) belonged to
group 1 and only 20 (30.8%) to group 2.
Eyes with final GSS3 were 7/84 (8.4%)
in group 1 and 5/84 (6.1%) in group 2
(p=0.6) (Fig. 2).
DISCUSSIONCCT is widely accepted as a key
parameter for the assessment of
patients with POAG. Many authors
have described the correlation
between CCT and glaucoma-related
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
Tab. Epidemiological data and results Dati epidemiologici e risultatiI
168 EYES/OCCHI:
84 (Group 1) 84 (Group 2)
SEX: Male 79 – Female 89 SESSO: Maschi 79 – Femmine 89
MEAN AGE (years): 58.8 ± 8.7ETA’ MEDIA (anni)
MEAN CCT GROUP 1 (micron): 526.7 ± 10.4CCT MEDIA GRUPPO 1
MEAN CCT GROUP 2 (micron): 576.2 ± 32.7CCT MEDIA GRUPPO 2 (micron)
BASELINE GSS: GSS1 GSS2
GROUP 1 66 pts. (78.5%) 18 pts. (21.5%)
GROUP 2 70 pts. (83.3%) 14 pts. (16.7%)
(p = 0.3)
FINAL GSS:GSS1 GSS2 GSS3
GROUP 1 39 pts. (46.4%) 38 pts. (45.2%) 7 pts. (8.4%)
GROUP 2 64 pts. (76.1%) 15 pts. (17.8%) 5 pts. (6.1%)
(p <0.001)
MEAN FOLLOW-UP (years): 4.6 ± 0.5FOLLOW-UP MEDIO (anni): 4,6± 0,5
90
damage or progression both in POAG
and in ocular hypertension10-23. The
major part of the studies measured
CCT with ultrasound pachymetry,
as in our case. Mean IOP is the only
currently consolidated modifiable
risk factor for the progression of
glaucoma-related damage, and
multiple randomised clinical trials have
provided evidence that the reduction
in intraocular pressure slows down
visual field deterioration in glaucoma
patients17-19. In the Early Manifest
Glaucoma Trial, which analysed the
effect of immediately reducing IOP
on the progression of open-angle
glaucoma, progression velocity in
treated patients was 45%20. Our
progression rate was 38.7%, though
we considered a smaller patient
population. All patients in our study
had pharmacologically controlled
IOP for the entire follow-up period;
hence, the probability of visual field
progression was independent from this
factor. Several randomised multicentre
clinical trials have identified IOP-
independent risk factors for glaucoma
progression. They include elderly
age, high cup-disc ratio, peripapillary
atrophy of the beta zone, low corneal
hysteresis, and pseudoexfoliation
syndrome. A thin central cornea is a
risk factor for conversion to glaucoma
dei pazienti con POAG. Molti autori hanno
descritto la correlazione tra CCT e danno
o progressione glaucomatosa sia nel
POAG che nell’ipertensione oculare10-23.
Nella maggior parte degli studi la CCT è
stata misurata mediante pachimetria ad
ultrasuoni come nel nostro caso. La IOP
media è l'unico, ormai consolidato,
fattore di rischio modificabile per la
progressione del danno glaucomatoso,
e molteplici studi clinici randomizzati
hanno dimostrato che l'abbassamento
della pressione intraoculare rallenta
il deterioramento del campo visivo in
pazienti affetti da glaucoma17-19. Nell’Early
Manifest Glaucoma Trial, che ha analizzato
l'effetto di ridurre immediatamente la
IOP sulla progressione del glaucoma ad
angolo aperto, la velocità di progressione
dei pazienti trattati è stata del 45%20.
Il nostro tasso di progressione è stato
del 38,7%, anche se abbiamo preso in
considerazione un campione più ridotto.
Tutti i pazienti del nostro studio avevano
una IOP controllata farmacologicamente
attraverso tutto il periodo di follow-up in
modo che la probabilità di progressione
del campo visivo era indipendente da tale
fattore. Diversi studi clinici randomizzati
multicentrici hanno identificato i fattori
di rischio IOP-indipendenti per la
progressione glaucomatosa. Essi
comprendono l'età avanzata, un
elevato rapporto cup-disc, atrofia della
Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
Fig. 2 Comparison of
patients assessed by
GSS stage at time
0 and after 4 years,
differentiated by CCT
Confronto tra pazienti
valutati secondo lo
stadio GSS al tempo
0 e dopo 4 anni,
differenziati secondo
CCT
2Fig.
GROUP 1 (CCT < 540 micron) GROUP 2 ( CCT > 540 micron )
Year 3 ı Number 2 ı 2017 91
zona beta peripapillare, diminuzione
dell’isteresi corneale, e la sindrome da
pseudoesfoliazione. Una cornea centrale
sottile è un fattore di rischio per la
conversione a glaucoma di pazienti con
ipertensione oculare, ma il rapporto tra
spessore corneale centrale e progressione
glaucomatosa rimane incerto11-19.
In uno studio osservazionale prospettico
su 861 occhi di pazienti normali, ipertesi
oculari e affetti da POAG, Jonas et al19
hanno dimostrato che lo sviluppo o la
progressione di difetti del campo visivo
era statisticamente indipendente dallo
spessore corneale centrale. Al contrario,
in un'analisi retrospettiva, multicentrica, di
una coorte di 230 pazienti ipertesi oculari
con 5 anni di follow-up, Konstas21 ha
trovato che i pazienti con cornee sottili
più spesso progredivano a glaucoma
conclamato. In uno studio retrospettivo
Hong et al12 hanno valutato l'associazione
di spessore centrale della cornea (CCT)
e progressione del campo visivo in
pazienti con glaucoma ad angolo chiuso
primario cronico (CPACG) con bassa
pressione intraoculare (IOP); un totale di
163 occhi e IOP <18 mmHg sono stati
inclusi nello studio; sulla base del valore
CCT, il campione è stato suddiviso in
due gruppi; gli autori descrivono che i
pazienti con CPACG con una cornea
più sottile sono a maggior rischio di
progressione del campo visivo, anche se
mantengono una IOP bassa dopo terapia.
Viswanathan et al5 hanno esaminato
163 occhi di 163 pazienti glaucomatosi
trattati con terapia medica e seguiti per
6,8 ± 1,8 anni; al follow-up iniziale una
più sottile CCT era associata a danni più
avanzati e gli occhi che progredivano
avevano una CCT inferiore rispetto agli
occhi che non mostravano progressione.
Kim et al6 in uno studio retrospettivo
caso-controllo hanno incluso 88 pazienti
con glaucoma primario ad angolo
aperto, glaucoma pseudoesfoliativo,
in patients with ocular hypertension,
but the ratio between central
corneal thickness and glaucoma
progression remains uncertain11-19.
In a prospective observational study
involving 861 eyes of normal patients,
patients with ocular hypertension
and patients with POAG, Jonas et
al19 reported that the development
or progression of visual field defects
was statistically independent from
central corneal thickness. Conversely,
in a retrospective multicentre study of
a cohort of 230 patients presenting
ocular hypertension with 5 year
follow-up, Konstas21 observed that
patients with thin corneas most often
progressed to full-blown glaucoma.
In a retrospective study, Hong et
al12 evaluated the association of
central corneal thickness (CCT) and
visual field progression in patients
with chronic primary closed-angle
glaucoma (CPACG) with low intraocular
pressure (IOP). A total number of
163 eyes with IOP <18 mmHg were
included in the study.
The patient population was divided into
two groups based on the CCT value.
The authors describe that patients with
CPACG with a thinner cornea present
a higher risk of visual field progression,
though they maintain a low IOP after
therapy. Viswanathan et al5 examined
163 eyes of 163 glaucoma patients
who were treated with medical therapy
and monitored for 6.8 ± 1.8 years.
At the initial follow-up visit a thinner
CCT was associated with more
advanced damages, and the eyes
that progressed had a lower CCT than
the eyes that showed no progression.
In a case-controlled retrospective
study, Kim et al6 included 88 patients
with primary open-angle glaucoma,
pseudoexfoliative glaucoma,
pigmentary glaucoma, or normal-
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
92
tension glaucoma who were monitored
for a mean period of 8 years.
Cases presenting progression were
compared by race, diagnosis, age and
pachymetry against progression-free
controls. Patients with thin corneas
had a greater probability of aggravation
than those with thicker CCT, and the
CCT was the only identified risk factor
that was significantly associated with
visual field progression. Iester22 too,
in a retrospective study conducted in
2012 on both eyes of 794 glaucoma
patients concluded that more severe
damage was associated with the
eye presenting thinner CCT than the
contralateral one. There is no formula
to calculate the risk of glaucoma
progression starting from a set of
initial data. GSS is currently the only
method that provides an immediate
and reliable classification both of the
gravity and type of visual field defects,
using 30-2 / 24-2 Zeiss-Humphrey
tests or G1 / G1X / G2 Octopus
programmes. Several studies have
proven that it is useful both in clinical
practice and in research, and it can
help to monitor defect progression
in the course of time9. We also
appreciated that GGS was useful to
classify glaucoma-related damage,
using the 24-2 Zeiss-Humphrey
test. All our patients included in the
baseline follow-up were within GSS
2, though the major part of them was
at GSS 1. Cases with a lower initial
pachymetric value had a significantly
higher probability of progression of
their initial GSS stage, as indicated
by the above authors. In the analysis
of the final GGS subgroups, it was
interesting to note that the number
of eyes that had reached GSS 3 was
identical in the two groups compared
(p=0.6), underscoring the fact that
a lower baseline pachymetric value
glaucoma pigmentario, o glaucoma a
tensione normale, seguiti per una media
di 8 anni; i casi con progressione sono
stati confrontati per razza, diagnosi, età
e pachimetria con i controlli che non
avevano avuto progressione. I pazienti
con cornee sottili avevano una maggiore
probabilità di peggiorare rispetto a quelli
con CCT più spessa e la CCT è stato
l'unico fattore di rischio identificato che
era significativamente associato con la
progressione del campo visivo. Anche
Iester22 in uno studio retrospettivo del
2012 condotto su entrambi gli occhi di
794 pazienti glaucomatosi concludeva
che un danno più severo era associato
all’occhio con CCT più sottile rispetto
a quello controlaterale. Non esiste una
formula con cui calcolare il rischio di
progressione glaucomatosa a partire
da una serie di dati iniziali. Il GSS è
attualmente l'unico metodo che fornisce
all'utente una classificazione immediata
e affidabile sia della gravità che del tipo
di difetti del campo visivo, utilizzando
i test 30-2 / 24-2 Zeiss-Humphrey o i
programmi G1 / G1X / G2 Octopus. Vari
studi hanno dimostrato che è utile sia
nella pratica clinica che nella ricerca e può
aiutare a monitorare la progressione difetto
nel corso del tempo9. Abbiamo anche
apprezzato l'utilità del GGS per classificare
i danni del glaucoma, utilizzando il 24-2
Zeiss-Humphrey test. Tutti i nostri pazienti
inclusi al follow-up basale si trovavano
entro il GSS 2, anche se la maggior parte
di loro era al GSS 1. I casi con un valore
pachimetrico iniziale inferiore avevano una
probabilità significativamente più alta di
una progressione del loro stadio GSS di
partenza come indicato dagli altri autori
di cui sopra. Nell’analisi dei sottogruppi
GGS finali è stato interessante notare che il
numero degli occhi che avevano raggiunto
un GSS 3 era sovrapponibile tra i due
gruppi a confronto (p=0.6), evidenziando
che nel glaucoma in stadi più avanzati un
Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
Year 3 ı Number 2 ı 2017 93
was not a negative prognostic factor
anymore for progression in the more
advanced stages of glaucoma. Our
hypothesis was that, in late glaucoma,
CCT would not play an important role
anymore but other systemic or local
risk factors might contribute to the final
clinical picture. According to Iester23,
the clinical trials at our disposal do
not prove that CCT is a risk factor
for the development of glaucoma;
hence, in glaucoma eyes, IOP must
be treated regardless of baseline CCT.
Further studies, perhaps prospective,
multicentre and randomised, should
be conducted to finally clarify the role
of corneal pachymetry in glaucoma
progression.
CONCLUSIONSIn pharmacologically compensated
primary open-angle glaucoma, the
visual field progression assessed
with GSS seems to be significantly
associated with a lower CCT. CCT
might not play a role in most advanced
glaucoma damage, while other risk
factors might contribute to the final
clinical picture.
valore pachimetrico basale più basso non
era più un fattore prognostico negativo
per la progressione. La nostra ipotesi è
stata che nel glaucoma tardivo la CCT
non svolgerebbe più un ruolo importante,
ma altri fattori di rischio sistemici o locali
potrebbero contribuire al quadro clinico
finale. Secondo Iester23 gli studi clinici a
nostra disposizione non dimostrano che la
CCT sia un fattore di rischio per lo sviluppo
del glaucoma perciò in occhi glaucomatosi
la IOP va trattata indipendentemente
dalla CCT basale. Ulteriori studi, magari
prospettici, multicentrici e randomizzati
dovrebbero essere svolti per chiarire
definitivamente il ruolo della pachimetria
corneale nella progressione del glaucoma.
CONCLUSIONINel glaucoma primario ad angolo aperto
farmacologicamente compensato,
la progressione del campo visivo
valutata con il GSS sembra essere
significativamente associata con una
CCT alla presentazione più sottile. Nel
danno glaucomatoso più avanzato la CCT
potrebbe non giocare un ruolo, ma altri
fattori di rischio contribuirebbero al quadro
clinico finale.
Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
REFERENCES1. Gordon MO, Beiser JA, Brandt JD, Heuer
DK, Higginbotham EJ, Johnson CA, et al.
The Ocular Hypertension Treatment Study:
Baseline factors that predict the onset
of primary open-angle glaucoma. Arch
Ophthalmol 2002;120:714-20
2. Ehlers N, Bramsen T, Sperling S.
Applanation tonometry and central corneal
thickness. Acta Ophthalmol (Copenh)
1975;53:34-43
3. Whitacre MM, Stein RA, Hassanein
K. The effect of corneal thickness on
applanation tonometry. Am J Ophthalmol
1993;115:592-96
4. Herndon LW, Choudhri SA, Cox T,
Damji KF, Shields MB, Allingham RR.
Central corneal thickness in normal,
glaucomatous, and ocular hypertensive
eyes. Arch Ophthalmol 1997;115:1137-41
5. Viswanathan D, Goldberg I, Graham
SL. Relationship of change in central
corneal thickness to visual field
progression in eyes with glaucoma.
Graefes Arch Clin Exp Ophthalmol
2013;251:1593-99
6. Kim JW, Chen PP. Central corneal
pachymetry and visual field progression
in patients with open-angle glaucoma.
Ophthalmology 2004;111:2126-32
94
7. Herndon LW, Weizer JS, Stinnett SS.
Central corneal thickness as a risk factor
for advanced glaucoma damage. Arch
Ophthalmol 2004;122:17-21
8. De Moraes CG, Juthani VJ, Liebmann JM,
Teng CC, Tello C, Susanna R Jr, Ritch R.
Risk factors for visual field progression
in treated glaucoma. Arch Ophthalmol
2011;129:562–68
9. Brusini P. Clinical use of a new method
for visual field damage classification in
glaucoma. Eur J Opthalmol 1996;6:402-7
10. European Glaucoma Prevention Study
(EGPS) Group, Miglior S, Pfeiffer N, Torri
V, Zeyen T, Cunha-Vaz J, Adamsons I.
Predictive factors for open-angle glaucoma
among patients with ocular hypertension in
the European Glaucoma Prevention Study.
Ophthalmology 2007;114:3-9
11. Medeiros FA, Sample PA, Weinreb RN.
Corneal thickness measurements and
visual function abnormalities in ocular
hypertensive patients. Am J Ophthalmol
2003;135:131-37
12. Hong S, Kim CY, Seong GJ, Hong YJ.
Central corneal thickness and visual
field progression in patients with chronic
primary angle-closure glaucoma with low
intraocular pressure. Am J Ophthalmol
2007;143:362-63
13. Francis BA, Varma R, Chopra V, Lai MY,
Shtir C, Azen SP, Los Angeles Latino
Eye Study Group. Intraocular pressure,
central corneal thickness, and prevalence
of open-angle glaucoma: the Los Angeles
Latino Eye Study. Am J Ophthalmol
2008;146:741-46
14. Medeiros FA, Weinreb RN. Is corneal
thickness an independent risk factor
for glaucoma? Ophthalmology
2012;119:435-36
15. Nemesure B, Wu SY, Hennis A, Leske
MC. Corneal thickness and intraocular
pressure in the Barbados Eye Studies.
Arch Ophthalmol 2003;121:240
16. Foster PJ, Baasanhu J, Alsbirk
PH, Munkhbayar D, Uranchimeg
D, Johnson GJ. Central corneal
thickness and intraocular pressure in a
Mongolian population. Ophthalmology
1998;105:969-73
17. Brandt JD, Gordon MO, Beiser JA, Lin
SC, Alexander MY, Kass MA, Ocular
Hypertension Treatment Study Group.
Changes in central corneal thickness over
time. Ophthalmology 2008;115:1550-56
18. Chauhan BC, Hutchison DM, LeBlanc RP,
Artes PH, Nicolela MT. Central corneal
thickness and progression of the visual
field and optic disc in glaucoma. Br J
Ophthalmol 2005;89:1008-12
19. Jonas JB, Stroux A, Velten I, Juenemann
A, Martus P, Budde WM. Central corneal
thickness correlated with glaucoma
damage and rate of progression. Invest
Ophthalmol Vis Sci 2005;46:1269-74
20. Leske MC, Heijl A, Hussein M, Bengtsson
B, Hyman L, Komaroff E, Early Manifest
Glaucoma Trial Group. Factors for
glaucoma progression and the effect of
treatment: the early manifest glaucoma
trial. Arch Ophthalmol 2003;121:48-56
21. Konstas AG, Irkec MT, Teus MA, Cvenkel
B, Astakhov YS, Sharpe ED, Hollo G,
Mylopoulos N, Bozkurt B, Pizzamiglio C,
Potyomkin VV, Alemu AM, Nasser QJ,
Stewart JA, Stewart WC. Mean intraocular
pressure and progression based on
corneal thickness in patients with ocular
hypertension. Eye (Lond.) 2009;23:73-8
22. Iester M, Telani S, Frezzotti P, Manni G,
Uva M, Figus M, Perdicchi A, and the
Italian Glaucoma Register. Differences
in central corneal thickness between
the paired eyes and the severity of the
glaucomatous damage. Eye (Lond.)
2012;26:1424-30
23. Iester M, Mete M, Figus M, Frezzotti P.
Incorporating corneal pachymetry into
the management of glaucoma. J Cataract
Refract Surg 2009;35:1623-28
Relationship between corneal pachymetry and perimeter damage evaluated with glaucoma staging system
Year 3 ı Number 2 ı 2017 95Rapporto tra pachimetria corneale e danno perimetrico valutato con glaucoma staging system
96Current evidences about the role of Cytidine 5’-Diphoshocholine (citicoline) in glaucoma
A BASE DI:Tea Tree OilBisabololoVitamina A
Gomma XanthanFosfolipidi S80
L’INNOVAZIONE NEL SUPPORTO AL TRATTAMENTO DELLA BLEFARITE
Year 3 ı Number 2 ı 2017 97
RIASSUNTOIl Cross-linking corneale (CXL) è volto ad
arrestare la progressione del cheratocono
ed è ampiamente considerato come la
metodica più efficace per il trattamento
di questa patologia. È normalmente
controindicato, tuttavia, in pazienti con
meno di 400 μm di spessore corneale,
lasciando al chirurgo oculista l’opzione
di praticare il CXL Transepiteliale,
generalmente reputato meno efficace.
Riportiamo dunque un nuovo approccio
per cornee ultra-sottili con cheratocono
avanzato, il Cross-linking Periferico (P-CXL),
con il quale l’epitelio corneale è rimosso
ma la porzione più sottile della cornea è
lasciata intatta, unitamente all’utilizzo di una
soluzione ipo-osmolare di riboflavina.
Il P-CXL è stato effettuato come
trattamento per un aggressivo cheratocono
al IV stadio, con pachimetria minima di 215
μm, Kmax di 89 D, 11,2 D di astigmatismo
e acuità visiva corretta di 20/1000. Nove
mesi dopo il P-CXL, la pachimetria minima
è aumentata di 101 μm, il Kmax è calato
di 0,9 D, l’astigmatismo di 3,1 D e l’acuità
visiva è salita a 20/100. Un maggior
numero di occhi operati ed un follow-up
più lungo supporterebbero la conferma di
questi dati notevolmente incoraggianti.
INTRODUZIONE ED OBIETTIVIIl cheratocono (KC) è un’ectasia corneale
non infiammatoria, generalmente bilaterale,
che si sviluppa prevalentemente nella
ABSTRACTCorneal Cross-linking (CXL) is aimed at
halting the progression of keratoconus
and is widely considered to be the
golden standard technique in the
treatment of this disease. It is usually
contraindicated, however, in patients with
less than 400 μm of corneal thickness,
leaving the ophthalmic surgeon with the
option of performing Transepithelial CXL,
usually regarded as less effective.
We report a novel approach for ultrathin
corneas with severe keratoconus,
Peripheral Corneal Cross-linking (P-CXL),
in which corneal epithelium is removed
but the thinnest part of the cornea is
left untouched, while a hypo-osmolar
riboflavin solution is used as well. P-CXL
was performed on an remarkably
developed stage IV keratoconus,
with thinnest pachymetry of 215 μm,
Kmax of 89 D, 11.2 D of astigmatism
and a 20/1000 BCVA. Nine months
after P-CXL, thinnest pachymetry
had increased by 101 μm, Kmax had
decreased by 0.9 D, astigmatism had
decreased by 3.1 D and BCVA had
improved to 20/100. A larger cohort
and a longer follow-up would be useful
for the confirmation of these noticeably
encouraging results.
INTRODUCTION AND OBJECTIVESKeratoconus (KC) is a bilateral
non-inflammatory corneal ectasia that
CORRESPONDING AUTHORMarco Abbondanza,
Abbondanza Eye Centers,
Via Luigi Bodio 58, 00191
Rome (RM), Italy and
Via S. Clemente 1,
20122 Milan (MI), Italy,
Ph: +39063207111
KEY WORDSKeratoconus, Corneal
Cross-linking, CXL, Cornea,
Peripheral Corneal Cross-
linking, P-CXL
PAROLE CHIAVECheratocono, Cross-linking,
CXL, Cornea, Cross-linking
Periferico, P-CXL
Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique
Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
Marco Abbondanza1, Valentina De Felice1, Gabriele Abbondanza1-2 1Abbondanza Eye Centers, Rome and Milan, Italy2University of Sydney, Sydney, Australia
98Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique
seconda decade di vita, caratterizzata
da una graduale perdita di spessore del
tessuto corneale e da una conseguente
forma dello stesso a guisa di cono1. Tale
distrofia corneale provoca astigmatismo
irregolare ed una progressiva perdita
dell’acuità visiva, una condizione che
richiede, nel 15-20% dei casi, un intervento
invasivo come il Trapianto di Cornea.
Le tecniche conservative, che mirano
a migliorare la capacità visiva e/o a
fermare l’ectasia negli stadi iniziali del KC,
comprendono il Cross-linking del Collagene
Corneale (CXL)2, la Mini Cheratotomia Radiale
Asimmetrica (MARK)3, la Cheratotomia
Circolare (CK/FemtoCK)4 e gli Inserti
Intracorneali (ICRS)5. Il CXL, la più recente fra
queste metodiche, è ad oggi ampiamente
considerata la tecnica più efficace per il
trattamento del cheratocono evolutivo,
una condizione dovuta al fatto che rettifica
l’intrinseca debolezza della cornea attraverso
un rinforzo del relativo stroma, fermando in tal
modo l’evoluzione della patologia.
Il protocollo standard del CXL (“epi-off”
o “Protocollo di Dresda”) è tuttavia
controindicato in pazienti con meno di
400 μm di spessore corneale a causa
di possibili danni all’endotelio, lasciando
l’opzione del Cross-linking Transepiteliale
(“epi-on”), una tecnica che provoca
minore disagio al paziente ma che è
considerata meno efficace, specialmente
quando utilizzata per forme aggressive
di cheratocono6. Gli autori (M.A.) hanno
dunque ideato un nuovo approccio per
il trattamento di cornee ultra-sottili con
cheratocono avanzato, una condizione
che richiede la massima efficacia da un
intervento chirurgico.
Il Cross-linking Periferico (P-CXL) richiede
la rimozione dell’epitelio come nella
modalità “epi-off”, ma lascia intatta una
piccola isola di epitelio sopra la porzione
più sottile di cornea, localizzata tramite
tomografia, assieme all’utilizzo di una
soluzione ipo-osmolare di riboflavina.
usually develops in the second decade
of life, characterized by a gradual loss
of thickness and subsequent change
into a more conical shape of the corneal
tissue1. This corneal dystrophy leads
to irregular astigmatism and decrease
in visual acuity, while, in 15 to 20% of
cases, an invasive intervention such as a
Corneal Transplantation (Corneal Graft)
may be required.
Conservatives techniques, aimed at
improving vision and/or halting the
ectasia in the early stages of KC, include
Corneal Collagen Cross-linking (CXL)2,
Mini Asymmetric Radial Keratotomy
(MARK)3, Circular Keratotomy
(CK/FemtoCK)4, and Intrastromal
Corneal Ring Segments (ICRS)5.
CXL, the most recent among these,
is now widely regarded as the most
effective treatment for progressive
keratoconus, due to the fact that it
directly addresses the intrinsic structural
weakness of the cornea by reinforcing
the corneal stroma, thus stopping the
evolution of KC.
The standard protocol of CXL (“epi-off”,
or the “Dresden Protocol”), however,
is contraindicated in patients with less
than 400 μm of corneal thickness,
due to the possibility of damage to the
endothelium. This leaves the option
of performing Transepithelial CXL
(“epi-on”), a technique that gives less
discomfort to the patient but is also
generally regarded as less effective,
especially when dealing with aggressive
forms of KC6. The authors (M.A.)
therefore conceived a novel approach
for the treatment of ultrathin corneas
with severe keratoconus, a condition
that requires the highest effectiveness
from a surgical intervention. Peripheral
Corneal Cross-linking (P-CXL) requires
epithelium removal as with the “epi-off”
technique, but leaves untouched a
small epithelium island on the thinnest
Year 3 ı Number 2 ı 2017 99Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
PRESENTAZIONE DEL CASONel settembre del 2015, un uomo di 55
anni si è presentato con un cheratocono
bilaterale diagnosticato 30 anni prima,
il cui occhio sinistro era in condizioni
decisamente peggiori. Il paziente usava lenti
a contatto ma lamentava una capacità visiva
molto scarsa. È stato sottoposto ad una
visita oculistica accurata, che ha compreso
misurazione di acuità visiva non corretta
(UCVA) e corretta (BCVA), tomografia
corneale, topografia corneale, biometria
assiale, pachimetria, conta delle cellule
endoteliali, cheratometria e biomicroscopia.
La BCVA dell’occhio sinistro era di
1,69 logMAR (20/1000, dunque cecità
legale), il Kmax era di 89 D, il Kmed era di
75,5 D, la pachimetria minima di 215 μm e
l’astigmatismo di 11,2 D (Fig. 1).
Con lo scopo di evitare una
Cheratoplastica Perforante (PKP), un
intervento che al paziente era già stato
prospettato altrove, abbiamo deciso di
intervenire in maniera conservativa con
la tecnica modificata del Cross-linking
Periferico (P-CXL). Un consenso
informato è stato richiesto come parte
della routine preoperatoria. L’anestesia
locale è consistita nell’applicazione
part of the cornea, located with a
tomographic examination, along with
the employment of a hypo-osmolar
riboflavin solution.
CASE PRESENTATIONIn September 2015, a 55-year-old
man presented with a progressive
bilateral KC diagnosed 30 years before,
whose left eye was in a considerably
worse condition. The patient had
been using contact lenses but
lamented very poor vision from his
left eye. The patient underwent a
thorough clinical examination, which
included measurement of uncorrected
(UCVA) and best corrected visual
acuity (BCVA), corneal tomography,
corneal topography, axial biometry,
pachymetry, endothelial cell count,
keratometry and slit lamp examination.
In his left eye BCVA was 1.69 logMAR
(20/1000, therefore legal blindness),
Kmax was 89 D, Kmed was 75.5 D,
thinnest pachymetry was 215 μm and
astigmatism was 11.2 D (Fig. 1).
With the aim of avoiding Penetrating
Keratoplasty (PKP), a procedure the
patient had been told elsewhere he
Fig. 1Sagittal map before P-CXL:
Kmax was 89 D
Mappa sagittale precedente
il P-CXL: Kmax di 89 D
1Fig.
100
di benoxinato cloridrato 0,4% e le
palpebre sono state tenute aperte con
un blefarostato. L’epitelio corneale
è stato rimosso con una spatola
oftalmica (MicroFeather;
Feather Safety Razor Co., Ltd., Osaka,
Giappone) e un microscopio operatorio,
mentre una piccola isola di epitelio,
localizzata attraverso l’ultima tomografia,
è stata lasciata intatta (Fig. 2).
Una soluzione iso-osmolare di
riboflavina è stata applicata 30 minuti
prima dell’applicazione dei raggi UV-A,
10 volte ad intervalli di 3 minuti, in
seguito alla quale è stata applicata
anche la soluzione ipo-osmolare
di riboflavina, così da aumentare
temporaneamente lo spessore
corneale. La soluzione iso-osmolare è
stata poi utilizzata 6 volte ad intervalli di
5 minuti durante l’applicazione dei raggi
UV-A, per un’esposizione totale di 30
minuti (sistema d’illuminazione UV-X,
versione 1000, IROC AG, Svizzera).
Una volta terminato il trattamento, è
stata applicata una lente a contatto
protettiva e sono stati prescritti
antibiotici topici e colliri antinfiammatori
non steroidei.
had to undergo, we decided to perform
a conservative intervention with the
modified technique of Peripheral
Corneal Cross-linking (P-CXL). A written
informed consent was required as a
part of our pre-operative routine. Topical
anesthesia was applied prior to the
treatment with benoxinate chloride 0.4%
drops and eyelids were kept open using
surgical forceps. Corneal epithelium
was removed with an ophthalmic
scalpel (MicroFeather; Feather Safety
Razor Co., Ltd., Osaka, Japan) and
a surgical microscope, while a small
epithelium island on the thinnest part
of the cornea, located with the latest
tomography, was left untouched (Fig. 2).
Iso-osmolar riboflavin solution was
applied 30 minutes before UV-A
application, 10 times at 3-minute
intervals, following which hypo-osmolar
riboflavin solution was also applied
every 20 seconds for 5 minutes,
thus temporarily improving corneal
thickness. Iso-osmolar riboflavin
was then applied 6 times at 5-minute
intervals during UV-A application, with a
total UV-A exposure time of 30 minutes
(UV-X illumination system version 1000,
2Fig.
Fig. 2P-CXL intervention: the
central epithelium island is
left untouched
L’intervento P-CXL: l’isola di
epitelio centrale è lasciata
intatta
Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique
Year 3 ı Number 2 ı 2017 101
RISULTATINove mesi dopo il Cross-linking
Periferico, il paziente ha ripetuto la
serie di esami effettuati nella fase
preoperatoria, mostrando un marcato
miglioramento sia in termini di regolarità
corneale che di spessore corneale
(Fig. 3). Il Kmax è sceso a 88,1 D, il
Kmed a 70 D, la pachimetria minima
è salita a 316 μm e l’astigmatismo
è sceso a 8,1 D, mentre la BCVA
è considerevolmente migliorata,
raggiungendo 0.69 logMAR (20/100)
(Tab. 1). Non sono state riscontrate
complicanze postoperatorie.
DISCUSSIONE E CONCLUSIONEOggi stiamo assistendo ad una generale
disponibilità di strumenti più accurati
per la diagnosi del cheratocono, oltre
che ad una crescente consapevolezza
della patologia da parte del pubblico,
una condizione che risulta in un
maggiore numero di persone cui viene
diagnosticato il KC. Ci troviamo di
fronte, tuttavia, alla sfida di trattare in
maniera appropriata quei pazienti che
hanno uno spessore corneale inferiore
ai 400 μm.
Stiamo inoltre assistendo ad un
continuo dibattito circa l’efficacia del
Cross-linking Transepiteliale, una
tecnica che provoca minore disagio
al paziente ma che è considerata meno
efficace6, un difetto che è stato riscontrato
IROC AG, Switzerland). Immediately
after CXL, we placed a bandage contact
lens and prescribed topical antibiotics
and non-steroidal anti-inflammatory
drops.
RESULTSNine months after Peripheral Corneal
Cross-linking, the patient repeated
the series of examinations performed
preoperatively, showing a strong
improvement in terms of both corneal
regularity and corneal thickness (Fig. 3).
Kmax was 88.1 D, Kmed was 70 D,
thinnest pachymetry was 316 μm and
astigmatism was 8.1 D, while BCVA
greatly improved, reaching 0.69 logMAR
(20/100) (table 1). No post-operative
complications were noted.
DISCUSSION AND CONCLUSIONToday we are witnessing the general
availability of more accurate instruments
for the diagnosis of keratoconus and
an increasing awareness of it by the
general public, a condition that has
resulted in an growing number of
patients that have been diagnosed with
a KC. We face, however, the challenge
of properly treating patients with corneal
thickness of less than 400 microns.
We are also witnessing an ongoing debate
regarding the validity of Transepithelial
Corneal Cross-linking, a technique that
gives less discomfort to the patient but is
Tab. pre- and post-P-CXL values, 9 months after the interventionValori pre- e post-P-CXL, 9 mesi dopo il trattamento1
Kmax Kmed Astigmatism Thinnest BCVA
Pachimetry
Before P-CXL 89 75.5 11.2 215 20/1000
After P-CXL 88.1 70 8.1 316 20/100
Difference -0.9 -5.5 -3.1 +101 /
Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
102
anche nel trattamento di pazienti pediatrici
con KC7-8. La nostra esperienza con il
CXL, cominciata nel 2005, ci ha portato
alla stessa conclusione e ci ha permesso
di ideare un nuovo approccio, tale che
possa trattare efficacemente pazienti
con cornee ultra-sottili senza correre
il rischio di effettuare un Cross-linking
Transepiteliale e non arrestare il
cheratocono.
Il Cross-linking Periferico (P-CXL) è
l’ultimo esempio di un protocollo CXL
modificato per includere e trattare pazienti
che normalmente verrebbero esclusi
dalla metodica standard, sviluppato
come un’alternativa al Cross-linking
Transepiteliale. Altri protocolli
modificati includono il Corneal Cross-
linking Accelerato9, il Pocket Corneal
Cross-linking10, il Contact Lens-Assisted
Collagen Cross-linking (CACXL)11 ed il CXL
con rimozione parziale dell’epitelio12, tutti i
quali mostrano risultati positivi e nessuna
necessità d’utilizzare il metodo “epi-on”,
oggi così comune.
Nel nostro caso, il Cross-linking Periferico
ha trattato con successo un cheratocono
notevolmente avanzato del IV stadio,
con Kmax di 89 D e pachimetria minima
di di 215 μm, senza fare ricorso ad
una Cheratoplastica Perforante. Resta
also generally regarded as less effective6,
something that has also been confirmed
in the treatment of pediatric patients with
KC7-8. Our experience with CXL, which
started in 2005, brought us to the same
conclusion and allowed us to conceive a
novel approach, one that could effectively
treat patients with ultrathin corneas
without running the risk of performing
Transepithelial CXL and not stopping
keratoconus.
Peripheral Corneal Cross-linking (P-CXL)
is the latest example of a modified
CXL protocol aimed at including and
treating patients that would normally be
excluded from the standard technique,
and was developed as an alternative
to Transepithelial CXL. Other modified
protocols include Accelerated Corneal
Cross-linking9, Pocket Corneal Cross-
linking10, Contact Lens-Assisted Collagen
Cross-linking (CACXL)11 and CXL with
partial epithelium removal12, all of which
showed promising results and no need
to perform the now-common “epi-on”
method.
In our case, Peripheral Corneal
Cross-linking was successful in treating
an remarkably developed stage IV
keratoconus, with Kmax of 89 D and
thinnest pachymetry of 215 μm, avoiding
Fig. 3Corneal tomography after
P-CXL: Kmax, Kmed and
astigmatism decreased
and thinnest pachimetry
strongly improved
La tomografia corneale in
seguito al P-CXL: Kmax,
Kmed e astigmatismo sono
diminuiti e lo spessore
corneale è fortemente
aumentato
3Fig.
Peripheral Corneal Cross-linking (P-CXL) as a treatment for an ultrathin cornea with stage IV keratoconus: a new technique
Year 3 ı Number 2 ı 2017 103
REFERENCES1. Rabinowitz YS. Keratoconus. Survey
Ophthalmol 1998;42:297-319
2) Spoerl E, Huhle M, Seiler T. Induction of
Cross-links in Corneal Tissue. Exp Eye Res
1998;66(1):97-103
3) Abbondanza M, Abdolrahimzadeh B,
Guidobaldi M. Combined Corneal Collagen
Cross-linking and Mini Asymmetric
Radial Keratotomy for the Treatment of
Keratoconus. Acta Medica International
2016;3:63-68
4) Krumeich JH, Keziran GH. Circular
Keratotomy to Reduce Astigmatism
and Improve Vision in Stage I and II
Keratoconus. J Refract Surg 2009;25:357-
365
5) Colin J, Cochener B, Savary G,
Malet F. Correcting keratoconus with
intracorneal rings. J Cataract Refract Surg
2000;26:1117-22
6) Wollensak G, Iomdina E. Biomechanical
and Histological Changes After Corneal
Crosslinking With and Without Epithelial
Debridement. J Cataract Refract Surg
2009;35:540-46
7) Buzzonetti L, Petrocelli G. Transepithelial
Corneal Cross-linking in Pediatric
Patients: Early Results. J Refract Surg
2012;28:763-67
8) Abbondanza M, Guidobaldi M. Corneal
Collagen Cross-linking in a Prepubescent
10-Year-Old Girl with Aggressive
Keratoconus. Int J Keratoconus and Ectatic
Corneal Diseases 2015;4:63-65
9) Touboul D, Efron N, Smadja D, Praud
D, Malet F, Colin J. Corneal Confocal
Microscopy Following Conventional,
Transepithelial, and Accelerated Corneal
Collagen Cross-linking Procedures
for Keratoconus. J Refract Surg
2012;28:769-76
10) Daxer A, Mahmoud HA, Venkateswaran
RS. Corneal Crosslinking and Visual
Rehabilitation in Keratoconus in One
Session Without Epithelial Debridement:
New Technique. Cornea 2010;29:1176-79
11) Jacob S, Kumar DA, Agarwal A, Basu S,
Sinha P, Agarwal A. Contact Lens-Assisted
Collagen Cross-linking (CACXL): A New
Technique for Cross-linking Thin Corneas.
J Refract Surg 2014;3:366-72
12) Hashemi H, Miraftab M, Hafezi F, Asgari
S. Matched comparison study of total and
partial epithelium removal in corneal cross-
linking. J Refract Surg 2015;31:110-15
13) Abbondanza M, Abdolrahimzadeh B,
Zuppardo M. Refractive Changes Following
CXL. Cataract and Refractive Surgery Today
Europe 2009;4:33-38
evidente che un numero maggiore
di pazienti trattati con P-CXL ed un
follow-up più lungo nel tempo sono
necessari per discutere una validità
più ampia delle conclusioni mostrate
in questo caso clinico. Incoraggiamo,
dunque, i colleghi chirurghi oculisti
ad utilizzare trattamenti che siano
sì conservativi, ma anche efficaci,
ogniqualvolta questo sia possibile,
specialmente quando il paziente sia molto
giovane o quando presenti uno stadio
particolarmente avanzato della patologia,
considerando che tali trattamenti
potrebbero evitare il ricorso al Trapianto
di Cornea e a successivi interventi di
chirurgia refrattiva13.
the need for a Penetrating Keratoplasty.
It is understood that a larger number of
patients treated with P-CXL and longer
follow-up periods are required, in order
to discuss the generalizability of the
findings presented in this case report. We
encourage fellow ophthalmic surgeons
to use conservative and yet effective
treatments whenever possible, especially
when dealing with very developed
keratoconus or very young patients,
considering that such treatments could
avoid the need for corneal transplantation
and subsequent refractive surgery13.
Cross-linking Periferico (P-CXL) per il trattamento di una cornea ultra-sottile con cheratocono al IV stadio: una nuova metodica
• Efficacia dimostrata nel ridurre la IOP1,3,4
• Basso livello di iperemia1,5
• Flaconi monodose privi di conservante1
IL PASSO SUCCESSIVO PER UN‘EFFICACIA SENZA CONSERVANTI1,2
1. Loyada RCP • 2. Terminology and Guidelines for Glaucoma, European Glaucoma Society 4th Edition 2014 • 3. Holló G et al, Adv Ther 2014; 31:932-944 • 4. Pfeiffer N et al, Adv Ther 2014 31:1228-1246 • 5. Ganfort RCP
Mat
eria
le p
rom
ozio
nale
dep
osita
to A
IFA in
dat
a: 1
0/0
4/2
017
Cod. LOY103
RIASSUNTO DELLE CARATTERISTICHE DEL PRODOTTO 1. DENOMINAZIONE DEL MEDICINALE Loyada 15 microgrammi/ml + 5 mg/ml collirio, soluzione in contenitore monodose. 2. COMPOSIZIONE QUALITATIVA E QUANTITATIVA Un ml di soluzione contiene: 15 microgrammi di tafluprost e 5 mg di timololo (come maleato). Un contenitore monodose (0,3 ml) di collirio, soluzione, contiene 4,5 microgrammi di tafluprost e 1,5 mg di timololo. Una goccia (circa 30 μl) contiene circa 0,45 microgrammi di tafluprost e 0,15 mg di timololo. Per l’elenco completo degli eccipienti, vedere paragrafo 6.1. 3. FORMA FARMACEUTICA Collirio, soluzione in contenitore monodose (collirio). Soluzione limpida e incolore con un pH di 6,0 6,7 e osmolalità pari a 290 370 mOsm/kg. 4. INFORMAZIONI CLINICHE 4.1 Indicazioni terapeutiche Riduzione della pressione intraoculare (IOP) in pazienti adulti con glaucoma ad angolo aperto o ipertensione oculare che non rispondono in maniera adeguata alla monoterapia topica con beta-bloccanti o analoghi delle prostaglandine e necessitano di una terapia di associazione e che trarrebbero beneficio dall’uso di colliri privi di conservanti. 4.2 Posologia e modo di somministrazione Posologia La terapia raccomandata è una goccia nel sacco congiuntivale dell’occhio(i) affetto(i) una volta al giorno. Se si dimentica una dose, il trattamento deve essere proseguito assumendo la dose successiva come pianificato. La dose non deve superare l’applicazione di una goccia al giorno nell’occhio(i) affetto(i). Loyada è una soluzione sterile priva di conservanti confezionata in contenitore monodose. Esclusivamente monouso, un contenitore è sufficiente per il trattamento di entrambi gli occhi. La soluzione non utilizzata deve essere eliminata immediatamente dopo l’uso. Popolazione pediatrica La sicurezza e l’efficacia di Loyada in bambini e adolescenti di età inferiore a 18 anni non sono state stabilite. Non ci sono dati disponibili. L’uso di Loyada non è raccomandato in bambini e adolescenti di età inferiore a 18 anni. Uso negli anziani Non c’è necessità di modificare la dose nei pazienti anziani. Uso in caso di compromissione renale/epatica I colliri a base di tafluprost e timololo non sono stati studiati in pazienti con compromissione renale/epatica pertanto Loyada deve essere utilizzato con cautela in questi pazienti. Modo di somministrazione Uso oftalmico Per ridurre il rischio di scurimento della cute palpebrale i pazienti devono rimuovere eventuali residui di soluzione dalla pelle. L’occlusione nasolacrimale o la chiusura delle palpebre per 2 minuti consente di diminuire l’assorbimento sistemico. In questo modo si può ottenere la riduzione degli effetti indesiderati sistemici e l’aumento dell’attività locale. Se si utilizza più di un medicinale oftalmico topico, i prodotti devono essere somministrati a distanza di almeno 5 minuti l’uno dall’altro. Le lenti a contatto devono essere rimosse prima dell’applicazione del collirio e possono essere rimesse dopo 15 minuti. Ai pazienti deve essere raccomandato di evitare di fare entrare il contenitore in contatto con l’occhio o con le strutture limitrofe al fine di evitare lesioni oculari (vedere le istruzioni per l’uso). Ai pazienti va inoltre spiegato che le soluzioni oculari, se non correttamente maneggiate, possono essere contaminate da batteri comuni, in grado di causare infezioni oculari. L’uso di soluzioni contaminate può arrecare gravi danni all’occhio e successiva perdita della vista. 4.3 Controindicazioni Ipersensibilità ai principi attivi o ad uno qualsiasi degli eccipienti elencati al paragrafo 6.1. Malattia reattiva delle vie aeree, incluse asma bronchiale o anamnesi di asma bronchiale, grave pneumopatia cronica ostruttiva. Bradicardia sinusale, sindrome del seno malato, inclusi blocco senoatriale, blocco atrioventricolare di secondo o terzo grado non controllato con pacemaker. Insufficienza cardiaca conclamata, shock cardiogeno. 4.4 Avvertenze speciali e precauzioni di impiego Effetti sistemici: Analogamente ad altri prodotti oftalmici a uso topico, tafluprost e timololo vengono assorbiti a livello sistemico. Per via della componente beta-adrenergica rappresentata dal timololo, è possibile incorrere negli stessi tipi di reazioni avverse cardiovascolari, polmonari o di altra natura osservati con la somministrazione di bloccanti beta-adrenergici sistemici. L’incidenza delle reazioni avverse sistemiche dopo la somministrazione oftalmica topica è inferiore rispetto a quanto riportato con la somministrazione sistemica. Per informazioni su come ridurre l’assorbimento sistemico vedere paragrafo 4.2. Patologie cardiache: Nei pazienti con malattie cardiovascolari (ad es. cardiopatia coronarica, angina di Prinzmetal e insufficienza cardiaca) e ipotensione, il trattamento con beta-bloccanti deve essere valutato con estrema cautela e occorre prendere in considerazione la terapia con altri principi attivi. I pazienti con malattie cardiovascolari devono essere tenuti sotto controllo per l’insorgenza di segni di peggioramento di tali patologie e di reazioni avverse. A causa degli effetti negativi sul tempo di conduzione, i beta-bloccanti devono essere somministrati con cautela unicamente a pazienti con blocco cardiaco di primo grado. Patologie vascolari: I pazienti con gravi problemi/disturbi della circolazione periferica (ossia forme gravi della malattia di Raynaud o della sindrome di Raynaud) devono essere trattati con cautela. Patologie respiratorie: In seguito alla somministrazione di alcuni beta-bloccanti oftalmici sono state segnalate reazioni respiratorie, inclusa la morte per broncospasmo in pazienti asmatici. Loyada deve essere utilizzato con cautela nei pazienti con pneumopatia cronica ostruttiva (COPD) lieve/moderata e solo nei casi in cui i potenziali benefici superino i rischi potenziali. Ipoglicemia/diabete: I beta-bloccanti devono essere somministrati con cautela nei pazienti con ipoglicemia spontanea o con diabete instabile, in quanto i beta-bloccanti possono mascherare i segni e i sintomi di un’ipoglicemia acuta. I beta-bloccanti possono inoltre mascherare eventuali segni di ipertiroidismo. L’interruzione improvvisa della terapia con beta-bloccanti può causare un rapido peggioramento dei sintomi. Malattie corneali: I beta-bloccanti oftalmici possono indurre secchezza oculare. I pazienti con malattie corneali devono essere trattati con cautela. Altri beta-bloccanti: L’effetto sulla pressione intraoculare o gli effetti noti del beta-blocco sistemico possono essere potenziati in caso di somministrazione di timololo (un componente di Loyada) a pazienti già in terapia con beta-bloccanti sistemici. La risposta di questi pazienti deve essere tenuta sotto stretta osservazione. L’uso di due bloccanti -adrenergici topici non è raccomandato. Glaucoma ad angolo chiuso: Nei pazienti con glaucoma ad angolo chiuso, l’obiettivo immediato del trattamento è ottenere la riapertura dell’angolo. Ciò richiede il restringimento della pupilla con un miotico. Timololo produce scarsi effetti o nessun effetto sulla pupilla. Se il timololo è usato per ridurre una pressione intraoculare elevata in presenza di glaucoma ad angolo chiuso, deve essere usato insieme a un miotico e non da solo. Reazioni anafilattiche: Durante il trattamento con beta-bloccanti, i pazienti con anamnesi di atopia o di grave reazione anafilattica a vari allergeni possono dimostrarsi maggiormente reattivi alla stimolazione ripetuta con tali allergeni e non responsivi alle dosi abituali di adrenalina utilizzate per il trattamento delle reazioni anafilattiche. Distacco di coroide: Il distacco di coroide è stato documentato a seguito della somministrazione di terapia soppressiva acquosa (ad es. timololo, acetazolamide) dopo procedure di filtrazione. Anestesia chirurgica: I preparati oftalmici ad azione beta-bloccante possono bloccare gli effetti beta-agonisti sistemici, ad esempio, dell’adrenalina. Se il paziente è in trattamento con timololo, l’anestesista deve essere informato. Prima di iniziare il trattamento, i pazienti devono essere informati in merito alla possibilità di cambiamenti nella crescita delle ciglia, scurimento della cute palpebrale e aumento della pigmentazione dell’iride in associazione all’uso di tafluprost. Alcuni di questi cambiamenti possono essere permanenti e possono causare differenze di aspetto tra i due occhi nel caso in cui il trattamento sia unilaterale. Il cambiamento della pigmentazione dell’iride è un processo lento che può richiedere diversi mesi per rendersi apprezzabile. Il cambiamento del colore dell’occhio è stato osservato soprattutto in pazienti con iridi a colorazione mista, ad es blu-marrone, grigio-marrone, giallo-marrone e verde-marrone. Nei casi di trattamento unilaterale, il rischio di eterocromia permanente è concreto. Non sono disponibili esperienze sull’uso di tafluprost in pazienti con glaucoma neovascolare, ad angolo chiuso, ad angolo stretto o congenito. Esiste solo un’esperienza limitata con tafluprost in pazienti afachici e con glaucoma pigmentario o pseudoesfoliativo. Si raccomanda cautela nell’uso di tafluprost in pazienti afachici, pseudofachici con lacerazione della capsula posteriore del cristallino o con lenti in camera anteriore o nei pazienti con fattori di rischio noti per edema maculare cistoide o iriti/uveiti. 4.5 Interazioni con altri medicinali ed altre forme di interazione Non sono stati effettuati studi d’interazione. Esiste un rischio potenziale di effetti additivi che causano ipotensione e/o bradicardia marcata in caso di somministrazione concomitante di una soluzione oftalmica a base di beta-bloccanti con calcioantagonisti orali, bloccanti beta-adrenergici, antiaritmici (incluso amiodarone), glicosidi digitalici, parasimpaticomimetici, guanetidina. La somministrazione di bloccanti -adrenergici orali può causare la riacutizzazione dell’ipertensione reattiva che può conseguire alla sospensione della clonidina. In caso di trattamento combinato con inibitori del CYP2D6 (ad es. chinidina, fluoxetina, paroxetina) e timololo è stato segnalato un potenziamento del beta-blocco sistemico (ad es. riduzione della frequenza cardiaca, depressione). Occasionalmente è stata segnalata midriasi secondaria a uso concomitante di beta-bloccanti oftalmici e adrenalina. 4.6 Fertilità, gravidanza e allattamento Gravidanza I dati relativi all’uso di Loyada in donne in gravidanza sono inesistenti o limitati. Le donne in età fertile devono usare misure contraccettive efficaci durante il trattamento con Loyada. Loyada non deve essere utilizzato durante la gravidanza a meno che non sia palesemente necessario (qualora non siano disponibili altre opzioni terapeutiche). Tafluprost: Non sono disponibili dati adeguati sull’uso di tafluprost nelle donne in gravidanza. Tafluprost può causare effetti farmacologici dannosi per la gravidanza e/o per il feto/neonato. Gli studi sugli animali hanno mostrato tossicità riproduttiva (vedere paragrafo 5.3). Il rischio potenziale per l’uomo non è noto. Timololo: Non sono disponibili dati adeguati sull’uso di timololo nelle donne in gravidanza. Timololo non deve essere utilizzato durante la gravidanza a meno che non sia palesemente necessario. Per informazioni su come ridurre l’assorbimento sistemico vedere paragrafo 4.2. Dagli studi epidemiologici non sono emersi effetti malformativi ma è stato evidenziato un rischio di ritardo di crescita intrauterina in caso di somministrazione di beta-bloccanti per via orale. Sono stati inoltre osservati segni e sintomi di beta-blocco (ad es. bradicardia, ipotensione, sofferenza respiratoria e ipoglicemia) nel neonato in caso di somministrazione di beta-bloccanti fino al momento del parto. Se la somministrazione di Loyada viene proseguita fino al parto, il neonato deve essere tenuto sotto stretto controllo durante i primi giorni di vita. Allattamento I beta-bloccanti sono escreti nel latte materno. Alle dosi terapeutiche di timololo in collirio è tuttavia improbabile che nel latte siano presenti quantità sufficienti a produrre sintomi clinici di beta-blocco nel lattante. Per informazioni su come ridurre l’assorbimento sistemico vedere il paragrafo 4.2. Non è noto se tafluprost e/o i relativi metaboliti siano escreti nel latte materno. I dati tossicologici disponibili da modelli animali hanno mostrato l’escrezione di tafluprost e/o dei relativi metaboliti nel latte (per maggiori dettagli vedere paragrafo 5.3). Alle dosi terapeutiche di tafluprost in collirio è tuttavia improbabile che nel latte siano presenti quantità sufficienti a produrre sintomi clinici nel lattante. A titolo precauzionale, l’allattamento non è raccomandato in caso di trattamento con Loyada. Fertilità Non sono disponibili dati sugli effetti di Loyada sulla fertilità umana. 4.7 Effetti sulla capacità di guidare veicoli e sull’uso di macchinari Non sono stati condotti studi sugli effetti di Loyada sulla capacità di guidare veicoli e usare macchinari. Se con l’instillazione del collirio si manifestano reazioni avverse come un temporaneo offuscamento della vista, il paziente deve attendere di sentirsi bene e aspettare che la vista ritorni nitida prima di mettersi alla guida o usare macchinari. 4.8 Effetti indesiderati Più di 484 pazienti sono stati trattati con Loyada nell’ambito di studi clinici. L’evento avverso correlato al trattamento riportato con maggiore frequenza è stato l’iperemia congiuntivale/oculare. Questo evento avverso si è verificato nel 7% circa dei pazienti coinvolti negli studi clinici condotti in Europa, si è manifestato con entità lieve nella maggior parte dei casi ed è stato associato all’interruzione del trattamento nell’1,2% dei pazienti. Le reazioni avverse
segnalate nel corso degli studi clinici su Loyada si sono limitate a quelle precedentemente documentate in relazione all’uso dei singoli principi attivi, tafluprost o timololo. Durante gli studi clinici non sono state osservate nuove reazioni avverse specifiche per Loyada. Nella maggior parte dei casi, le reazioni avverse sono state di tipo oculare e di entità lieve o moderata; nessuna ha assunto connotazioni gravi. Analogamente ad altri prodotti oftalmici a uso topico, tafluprost e timololo vengono assorbiti a livello sistemico. Ciò può causare effetti indesiderati simili a quelli osservati con i beta-bloccanti sistemici. L’incidenza delle reazioni avverse sistemiche dopo somministrazione oftalmica topica è inferiore rispetto a quanto segnalato con la somministrazione sistemica. Le reazioni avverse elencate includono le reazioni osservate all’interno della classe dei beta-bloccanti oftalmici. Le seguenti reazioni avverse sono state segnalate nell’ambito di studi clinici su Loyada (all’interno di ciascuna categoria di frequenza, le reazioni avverse sono presentate in ordine di frequenza decrescente). La frequenza delle possibili reazioni avverse sotto elencate è definita sulla base della seguente convenzione:
Molto comune ≥1/10
Comune ≥1/100, <1/10
Non comune ≥1/1.000, <1/100
Rara ≥1/10.000, <1/1.000
Molto rara <1/10.000
Non nota La frequenza non può essere definita sulla base dei dati disponibili
Loyada (tafluprost/timololo in associazione)
Classificazione per sistemi e organi Frequenza Reazioni avverse
Patologie del sistema nervoso Non comune Cefalea
Patologie dell’occhio Comune Iperemia congiuntivale/oculare, prurito oculare, dolore oculare, alterazioni delle ciglia (aumento di lunghezza, spessore e numero), alterazione del colore delle ciglia, irritazione oculare, sensazione di corpo estraneo negli occhi, visione offuscata, fotofobia.
Non comune Sensibilità oculare anormale, secchezza oculare, fastidio oculare, congiuntiviti, eritema palpebrale, allergia oculare, edema palpebrale, cheratiti puntata superficiale, aumento della lacrimazione, infiammazione della camera anteriore, astenopia, blefariti.
Di seguito sono riportate altre reazioni avverse osservate con i singoli principi attivi (tafluprost o timololo) e che possono manifestarsi anche con Loyada:
Timololo
Classificazione per sistemi e organi Reazioni avverse
Disturbi del sistema immunitario Segni e sintomi di reazioni allergiche inclusi angioedema, orticaria, eruzione cutanea localizzata e generalizzata, anafilassi, prurito.
Disturbi del metabolismo e della nutrizione
Ipoglicemia.
Disturbi psichiatrici Depressione, insonnia, incubi, perdita di memoria, nervosismo.
Patologie del sistema nervoso Capogiro, sincope, parestesia, aumento dei segni e dei sintomi di miastenia grave, accidente cerebrovascolare, ischemia cerebrale.
Patologie dell’occhio Cheratite, ridotta sensibilità corneale, disturbi visivi inclusi cambiamenti di rifrazione (dovuti in alcuni casi alla sospensione della terapia miotica), ptosi, diplopia, distacco di coroide conseguente a intervento di chirurgia filtrante, (vedere paragrafo 4.4 “Avvertenze speciali e precauzioni di impiego”), lacerazione, erosione della cornea.
Patologie dell’orecchio e del labirinto Tinnito.
Patologie cardiache Bradicardia, dolore toracico, palpitazioni, edema, aritmia, insufficienza cardiaca congestizia, arresto cardiaco, blocco cardiaco, blocco atrioventricolare, insufficienza cardiaca.
Patologie vascolari Ipotensione, claudicazione, fenomeno di Raynaud, mani e piedi freddi.
Patologie respiratorie, toraciche e mediastiniche
Dispnea, broncospasmo (prevalentemente in pazienti con malattia broncospastica preesistente), insufficienza respiratoria, tosse.
Patologie gastrointestinali Nausea, dispepsia, diarrea, bocca secca, disgeusia, dolore addominale, vomito.
Patologie della cute e del tessuto sottocutaneo Alopecia, eruzione cutanea psoriasiforme o aggravamento della psoriasi, eruzione cutanea.
Patologie del sistema muscoloscheletrico e del tessuto connettivo
Lupus eritematoso sistemico, mialgia, artropatia.
Patologie dell’apparato riproduttivo e della mammella
Malattia di Peyronie, calo della libido, disfunzione sessuale.
Patologie sistemiche e condizioni relative alla sede di somministrazione
Astenia/affaticamento, sete.
In alcuni pazienti con cornea significativamente danneggiata sono stati segnalati casi molto rari di calcificazione corneale in associazione all’uso di colliri contenenti fosfato. Segnalazione delle reazioni avverse sospette La segnalazione delle reazioni avverse sospette che si verificano dopo l’autorizzazione del medicinale è importante, in quanto permette un monitoraggio continuo del rapporto beneficio/rischio del medicinale. Agli operatori sanitari è richiesto di segnalare qualsiasi reazione avversa sospetta tramite il sistema nazionale di segnalazione all’indirizzo: www.agenziafarmaco.gov.it/it/responsabili. 4.9 Sovradosaggio È improbabile che si verifichi un sovradosaggio topico con tafluprost o che sia associato a tossicità. Sono stati riportati casi di sovradosaggio accidentale con timololo, con conseguenti effetti sistemici simili a quelli osservati con i bloccanti beta-adrenergici sistemici, tra cui capogiro, cefalea, respiro corto, bradicardia, broncospasmo e arresto cardiaco (vedere anche paragrafo 4.8). In caso di sovradosaggio con Loyada, il trattamento deve essere sintomatico e di supporto. Timololo non è rimosso rapidamente mediante dialisi. 5. PROPRIETÀ FARMACOLOGICHE 5.1 Proprietà farmacodinamiche Categoria farmacoterapeutica: preparati antiglaucoma e miotici, beta-bloccanti, codice ATC: S01ED51 Meccanismo d’azione Loyada è una combinazione fissa di due principi attivi: tafluprost e timololo. Questi due principi attivi riducono la pressione intraoculare (IOP) sfruttando meccanismi d’azione complementari e il loro effetto combinato determina un’ulteriore riduzione della pressione intraoculare rispetto ai due preparati usati singolarmente. Tafluprost è un analogo fluorinato della prostaglandina F2 . Tafluprost acido, il metabolita biologicamente attivo di tafluprost, è un agonista altamente potente e selettivo del recettore prostanoide umano FP. Studi di farmacodinamica sulla scimmia indicano che tafluprost riduce la pressione intraoculare aumentando il deflusso uveosclerale dell’umore acqueo. Timololo maleato è un bloccante non selettivo del recettore beta-adrenergico. L’esatto meccanismo d’azione di timololo maleato nella riduzione della pressione intraoculare non è ancora stato chiaramente definito, sebbene uno studio con fluoresceina e altri studi di tonografia indicano che la sua azione prevalente possa essere correlata a una minore formazione di umore acqueo. In alcuni studi, tuttavia, è stato osservato anche un leggero aumento della facilità di deflusso. Efficacia clinica In uno studio della durata di 6 mesi (n=400) condotto su pazienti con glaucoma ad angolo aperto o ipertensione oculare e pressioni intraoculari medie non trattate comprese tra 24 e 26 mmHg, l’effetto di riduzione della pressione intraoculare esercitato da Loyada (somministrato una volta al giorno, al mattino) è stato messo a confronto con la somministrazione concomitante di tafluprost allo 0,0015% (una volta al giorno, al mattino) e timololo allo 0,5% (due volte al giorno). Loyada si è dimostrato non inferiore all’effetto di tafluprost 0,0015% e timololo 0,5% usati in concomitanza a tutti i timepoint e a tutte le visite, utilizzando il comune margine di non inferiorità di 1,5 mmHg. La riduzione diurna media della pressione intraoculare rispetto al basale è stata pari a 8 mmHg in entrambi i bracci
all’endpoint primario di 6 mesi (con riduzioni comprese tra 7 e 9 mmHg in entrambi i bracci ai vari timepoint nell’arco della giornata in occasione delle visite dello studio). In un altro studio della durata di 6 mesi (n=564) Loyada è stato messo a confronto con le rispettive monoterapie in pazienti affetti da glaucoma ad angolo aperto o ipertensione oculare e con pressioni intraoculari medie non trattate comprese tra 26 e 27 mmHg. I pazienti non adeguatamente controllati con tafluprost 0,0015% (pressione intraoculare pari o superiore a 20 mmHg in corso di terapia) o con timololo 0,5% (pressione intraoculare pari o superiore a 22 mmHg in corso di terapia) sono stati randomizzati al trattamento con Loyada o con la stessa monoterapia. Alle visite della settimana 6, del mese 3 (endpoint primario di efficacia) e del mese 6, la riduzione diurna media della pressione intraoculare con Loyada è risultata statisticamente superiore a quella ottenuta con tafluprost somministrato una volta al giorno al mattino o con timololo somministrato due volte al giorno. La riduzione diurna media della pressione intraoculare rispetto al basale ottenuta con Loyada a 3 mesi è stata pari a 9 mmHg, a fronte di una riduzione di 7 mmHg documentata con entrambe le monoterapie. Le riduzioni della pressione intraoculare ottenute con Loyada ai vari timepoint nell’arco della giornata in occasione delle visite variavano dagli 8 ai 9 mmHg per il gruppo di confronto trattato con tafluprost in monoterapia e dai 7 ai 9 mmHg per il gruppo di confronto trattato con timololo in monoterapia. I dati combinati dei pazienti trattati con Loyada con un’elevata pressione intraoculare al basale di 26 mmHg (media diurna) o superiore in questi due studi pilota (n=168) hanno mostrato che la riduzione diurna media della pressione intraoculare era pari a 10 mmHg all’endpoint primario (3 o 6 mesi), con valori compresi tra 9 e 12 mmHg ai vari timepoint durante l’arco della giornata. L’Agenzia europea dei medicinali ha previsto l’esonero dall’obbligo di presentare i risultati degli studi con Loyada in tutti i sottogruppi della popolazione pediatrica (vedere paragrafo 4.2 per informazioni sull’uso pediatrico). 5.2 Proprietà farmacocinetiche Assorbimento Le concentrazioni plasmatiche di tafluprost acido e timololo sono state studiate in volontari sani dopo somministrazione oculare singola e ripetuta di Loyada per otto giorni (una volta al giorno), tafluprost 0,0015% (una volta al giorno) e timololo 0,5% (due volte al giorno). Le concentrazioni plasmatiche di tafluprost acido raggiungevano il picco 10 minuti dopo la somministrazione e tornavano a valori al di sotto del limite inferiore di rilevabilità (10 pg/ml) prima che fossero trascorsi 30 minuti dalla somministrazione di Loyada. L’accumulo di tafluprost acido risultava trascurabile e l’AUC0-last media (monoterapia: 4,45±2,57 pg·h/ml; Loyada: 3,60±3,70 pg·h/ml) e la Cmax media (monoterapia: 23,9±11,8 pg/ml; Loyada: 18,7±11,9 pg/ml) di tafluprost acido risultavano entrambe leggermente più basse con Loyada rispetto a quanto osservato con tafluprost in monoterapia il giorno 8. Le concentrazioni plasmatiche di timololo raggiungevano il picco a valori di Tmax mediani di 15 e 37,5 minuti dopo la somministrazione di Loyada rispettivamente nei giorni 1 e 8. Il giorno 8, l’AUC0-last media di timololo (monoterapia: 5.750±2.440 pg·h/ml; Loyada:4.560±2.980 pg·h/ml) e la sua Cmax media (monoterapia: 1.100±550 pg/ml; Loyada: 840±520 pg/ml) risultavano entrambe in una certa misura più basse con Loyada rispetto a quanto osservato con timololo in monoterapia. La più bassa esposizione plasmatica a timololo ottenuta con Loyada sembra essere dovuta al regime di somministrazione una volta al giorno adottato con Loyada rispetto al regime di duplice somministrazione giornaliera impiegato con timololo in monoterapia. Tafluprost e timololo vengono assorbiti attraverso la cornea. Nel coniglio, la penetrazione corneale di tafluprost con l’uso di Loyada è risultata simile a quella ottenuta con tafluprost monopreparato dopo un’unica instillazione, mentre la penetrazione di timololo con Loyada risultava leggermente inferiore al confronto con timololo monopreparato. Per tafluprost acido, l’AUC4h era di 7,5 ng·h/ml dopo la somministrazione di Loyada e 7,7 ng·h/ml dopo la somministrazione di tafluprost monopreparato. Per timololo, l’AUC4h
era pari a 585 ng·h/ml e 737 ng·h/ml rispettivamente dopo la somministrazione di Loyada e timololo monopreparato. Il Tmax per tafluprost acido era di 60 minuti sia con Loyada sia con tafluprost monopreparato, mentre per timololo il Tmax era di 60 min con Loyada e di 30 min con timololo monopreparato. Distribuzione Tafluprost Nella scimmia non è stata osservata una distribuzione specifica di tafluprost radiomarcato nel corpo irido-ciliare o nella coroide, compreso l’epitelio pigmentato retinico, indizio di bassa affinità per il pigmento melanina. In uno studio di autoradiografia dell’intero organismo condotto sul ratto, la concentrazione più elevata di radioattività è stata rilevata nella cornea, seguita dalle palpebre, dalla sclera e dall’iride. Al di fuori dell’occhio, la radioattività era distribuita a livello di apparato lacrimale, palato, esofago e tratto gastrointestinale, rene, fegato, cistifellea e vescica urinaria. Il legame di tafluprost acido all’albumina sierica umana in vitro è stato del 99% con 500 ng/ml di tafluprost acido. Timololo Nel coniglio, il livello di picco della radioattività correlata a timololo nell’umore acqueo è stato raggiunto dopo 30 minuti da un’applicazione singola di timololo 3H-radiomarcato (soluzione allo 0,5%: 20 μl/occhio) in entrambi gli occhi. Timololo viene eliminato dall’umore acqueo molto più rapidamente di quanto avvenga nei tessuti pigmentati dell’iride e del corpo ciliare. Biotrasformazione Tafluprost La principale via metabolica di tafluprost nell’uomo, sulla base di test in vitro, consiste nell’idrolisi al metabolita farmacologicamente attivo, tafluprost acido, che viene ulteriormente metabolizzato per glucuronidazione o betaossidazione. I prodotti della betaossidazione, acidi 1,2-dinor e 1,2,3,4-tetranor di tafluprost, farmacologicamente inattivi, possono essere glucuronidati o idrossilati. Il sistema enzimatico del citocromo P450 (CYP) non partecipa al metabolismo di tafluprost acido. In base allo studio del tessuto corneale del coniglio con enzimi purificati, la principale esterasi responsabile dell’idrolisi dell’estere a tafluprost acido è la carbossilesterasi. All’idrolisi può inoltre contribuire la butilcolinesterasi, ma non l’acetilcolinesterasi. Timololo Timololo è metabolizzato a livello epatico prevalentemente dall’enzima CYP2D6 in metaboliti inattivi, che vengono escreti principalmente per via renale. Eliminazione Tafluprost Nel ratto, in seguito alla somministrazione di una sola dose giornaliera di 3H-tafluprost (soluzione oftalmica allo 0,005%; 5 μl/occhio) per 21 giorni in entrambi gli occhi, è stato ritrovato negli escreti l’87% circa della dose radioattiva totale. La percentuale della dose totale rinvenuta nelle urine era pari al 27 38% circa, mentre quella escreta con le feci era del 44 58% circa. Timololo L’emivita apparente di eliminazione dal plasma umano è di circa 4 ore. Timololo è ampiamente metabolizzato nel fegato e i metaboliti sono escreti con le urine congiuntamente a un 20% di timololo immodificato in seguito a somministrazione orale. 5.3 Dati preclinici di sicurezza Loyada I dati preclinici non rivelano rischi particolari per l’uomo sulla base di studi di tossicità a dosi ripetute e di studi di farmacocinetica oculare. Il profilo di sicurezza oculare e sistemica dei singoli componenti è chiaramente definito. Tafluprost I dati preclinici non rivelano rischi particolari per l’uomo sulla base di studi convenzionali di sicurezza, farmacologia, tossicità sistemica a dosi ripetute, genotossicità e potenziale cancerogeno. Analogamente a quanto osservato con altri agonisti di PGF2, la somministrazione topica oculare di dosi ripetute di tafluprost nelle scimmie ha prodotto effetti irreversibili sulla pigmentazione dell’iride e un aumento reversibile dell’ampiezza della fessura palpebrale. Nel ratto e nel coniglio è stata osservata un’aumentata contrattilità uterina in vitro con concentrazioni di tafluprost acido che superavano rispettivamente di 4 e 40 volte le concentrazioni plasmatiche massime di tafluprost acido nell’uomo. L’attività uterotonica di tafluprost non è stata testata in preparati uterini umani. Studi di tossicità riproduttiva sono stati condotti sul ratto e sul coniglio con somministrazione endovenosa. Nel ratto non sono stati osservati effetti avversi sulla fertilità o sulle fasi precoci dello sviluppo embrionale con esposizioni sistemiche oltre 12.000 volte l’esposizione clinica massima basata sulla Cmax o superiori a 2.200 volte basata sull’AUC. In studi convenzionali di sviluppo embrio-fetale, tafluprost ha indotto una riduzione del peso corporeo fetale e un aumento delle perdite post-impianto. Tafluprost ha aumentato l’incidenza di anomalie scheletriche nel ratto e l’incidenza di malformazioni craniche, cerebrali e spinali nel coniglio. Nello studio condotto sul coniglio, i livelli plasmatici di tafluprost e dei relativi metaboliti sono risultati inferiori al livello di quantificazione. In uno studio sullo sviluppo pre- e postnatale condotto sul ratto è stato osservato un aumento della mortalità neonatale, una riduzione del peso corporeo e un dispiegamento ritardato del padiglione auricolare nella prole esposta a dosi di tafluprost 20 volte superiori alla dose clinica. Gli esperimenti condotti con tafluprost radiomarcato nel ratto hanno dimostrato che lo 0,1% circa della dose applicata topicamente a livello oculare passava nel latte. Poiché l’emivita del metabolita attivo (tafluprost acido) nel plasma è molto breve (nell’uomo cessa di essere rilevabile dopo 30 minuti), la maggior parte della radioattività era probabilmente riconducibile a metaboliti con attività farmacologica scarsa o nulla. Sulla base del metabolismo di tafluprost e delle prostaglandine naturali, ci si attende una biodisponibilità orale molto bassa. Timololo I dati preclinici non rivelano rischi particolari per l’uomo sulla base di studi convenzionali di sicurezza farmacologica, tossicità a dosi ripetute, genotossicità, potenziale cancerogeno e tossicità riproduttiva. 6. INFORMAZIONI FARMACEUTICHE 6.1 Elenco degli eccipienti Glicerolo · Disodio fosfato dodecaidrato · Disodio edetato · Polisorbato 80 · Acido cloridrico e/o sodio idrossido per l’aggiustamento del pH · Acqua per preparazioni iniettabili. 6.2 Incompatibilità Non pertinente 6.3 Periodo di validità 3 anni · Dopo la prima apertura della busta di alluminio: 28 giorni. 6.4 Precauzioni particolari per la conservazione Conservare in frigorifero (2°C - 8°C). Dopo l’apertura della busta di alluminio: • Conservare i contenitori monodose nella busta di alluminio originale per proteggere il medicinale dalla luce. • Non conservare a temperatura superiore ai 25°C. • Eliminare i contenitori monodose aperti e la soluzione eventualmente rimasta immediatamente dopo l’uso. 6.5 Natura e contenuto del contenitore Contenitori monodose in polietilene a bassa densità (LDPE) confezionati in una busta in laminato alluminio-polietilene rivestito con carta. Ogni contenitore monodose ha un volume di riempimento di 0,3 ml e ogni busta di alluminio racchiude 10 contenitori. Sono disponibili le seguenti confezioni: 30 contenitori monodose da 0,3 ml e 90 contenitori monodose da 0,3 ml. È possibile che non tutte le confezioni siano commercializzate. 6.6 Precauzioni particolari per lo smaltimento e la manipolazione Il medicinale non utilizzato e i rifiuti derivati da tale medicinale devono essere smaltiti in conformità alla normativa locale vigente. 7. TITOLARE DELL’AUTORIZZAZIONE ALL’IMMISSIONE IN COMMERCIO Santen Italy S.r.l. · Via Roberto Lepetit 8/10 · 20124 Milano 8. NUMERO(I) DELL’AUTORIZZAZIONE ALL’IMMISSIONE IN COMMERCIO A IC n.043622012 - “15 microgrammi /ml + 5 mg/ml collirio, soluzione” 30 × 0,3ml contenitori monodose in LDPE · AIC n.043622024 - “15 microgrammi/ml + 5 mg/ml collirio, soluzione” 90 × 0,3ml contenitori monodose in LDPE 9. DATA DELLA PRIMA AUTORIZZAZIONE/RINNOVO DELL’AUTORIZZAZIONE Data della prima autorizzazione: 04 marzo 2015 10. DATA DI REVISIONE DEL TESTO 04/2015 CLASSIFICAZIONE AI FINI DELLA FORNITURA, CLASSE DI RIMBORSABILITÀ E PREZZO LOYADA «15 microgrammi/ml + 5 mg/ml collirio, soluzione» 30 × 0,3 ml contenitori monodose in LDPE (A.I.C. n. 043622012). Classificazione ai fini della fornitura: medicinale soggetto a prescrizione medica (RR). Classe di rimborsabilità: classe A Prezzo al pubblico (I.V.A. inclusa): € 30,41 • LOYADA «15 microgrammi/ml + 5 mg/ml collirio, soluzione» 90 × 0,3ml contenitori monodose in LDPE (AIC n.043622024). Classificazione ai fini della fornitura: medicinale soggetto a prescrizione medica (RR). Classe di rimborsabilità: classe A · Prezzo al pubblico (I.V.A. inclusa): € 91,23.
Focus on...108
XEN45 si posiziona tra la terapia
farmacologica e la più aggressiva
chirurgia tradizionale2. L’impianto
è indicato nei casi di scarsa
compliance, di terapia medica
inefficace, nei casi ad alto rischio
di complicanze con altri interventi
e nel paziente che non vuole
abbandonare l’utilizzo delle lenti a
contatto.
In passato, l'opzione chirurgica era
riservata esclusivamente a pazienti
con glaucoma di grado medio/
elevato non rispondenti alla terapia
Introduzione
XEN45 è una tecnica filtrante
mininvasiva della chirurgia del
glaucoma con accesso ab interno,
indicata in pazienti con glaucoma ad
angolo aperto (OAG). Per chirurgia
filtrante si intende l’ottenimento
di una riduzione della pressione
intraoculare (PIO) attraverso la
formazione di una via di drenaggio
artificiale dalla camera anteriore allo
spazio sottocongiuntivale (Fig. 1)1.
Nell’algoritmo terapeutico di
gestione dei pazienti con OAG,
medica e la trabeculectomia era
la procedura di scelta, però con
un rischio non trascurabile di gravi
complicanze intra e postoperatorie1,3.
Oggi, anche al paziente con
glaucoma di grado lieve/moderato
può essere proposta l’opzione
chirurgica (MIGS) con un profilo di
sicurezza maggiore ed un minor
trauma chirurgico e conseguente
minor risposta infiammatoria1,3.
XEN45 gel implant (gelatina di
derivazione suina cross-linked), è
un tubicino di 45 μm di lume interno,
6 mm di lunghezza, flessibile che
si conforma ai tessuti circostanti
durante la fase di impianto.
La sua mini-invasività permette di
non traumatizzare la congiuntiva ed
è possibile eseguire la procedura
su pazienti fachici, pseudofachici e
anche associata all’asportazione di
cataratta.
Una volta posizionato, il suo
diametro esterno si espande da
150 μm a 250 μm per idratazione
e al suo interno si stabilisce un
flusso laminare non turbolento che
drena l’umore acqueo nello spazio
sottocongiuntivale in maniera
controllata 2,3 μl/min.
CHIRURGIA FILTRANTE MININVASIVA DEL GLAUCOMA: L’IMPIANTO DI XEN45 NELLA NOSTRA ESPERIENZA
Laura Moschetta1, Gian Luca Laffi21 Medico Chirurgo e Ortottista, Bologna, Italia2 Medico Chirurgo Oculista, Policlinico S. Orsola-Malpighi, Ospedale San Marino, Studio d’Azeglio, Bologna, Italia
Fig. 1aXEN45 a livello del trabecolato ben visibile alla
gonioscopia.
Fig. 1bBozza spugnosa, ben permeabile dopo 1 mese
dall’impianto di XEN45 ben visibile all’OCT.
1bFig.
1aFig.
Focus on...
Metodi
Studio retrospettivo di coorte su
pazienti sottoposti ad impianto
XEN45 da parte di un singolo
chirurgo da maggio 2016 a marzo
2017. L’impianto XEN45 è stato
effettuato previa somministrazione
sottocongiuntivale intraoperatoria di
0,1 ml di mitomicina C (MMC) allo 0,2
mg/ml, incisura corneale, approccio
ab interno all’angolo irido-corneale,
formazione di tunnel sclerale tramite
iniettore e posizionamento del device
sotto la congiuntiva.
Si riportano le principali
caratteristiche demografiche e
cliniche dei partecipanti in tabella 1.
Tra le caratteristiche postoperatorie
sono state indagate: PIO (metodo
applanazione Goldmann), numero
di principi attivi utilizzati (colliri +/-
Acetazolamide per os), complicanze
intra e postoperatorie. I dati sono
stati valutati per ciascun paziente
ai seguenti tempi di follow-up: 1
settimana, 1, 3, 6, 8 mesi dalla data
dell’intervento. I valori numerici,
distribuiti in maniera gaussiana,
sono stati espressi in media (Valore
massimo-Valore minimo). È stato
infine calcolato il numero di pazienti
con Complete Success (PIO 5-18
mmHg e nessuna terapia), Success
(PIO 5-18 mmHg con terapia), No
Success (PIO ≥ 21 mmHg con o
senza terapia) all’ultimo follow-up per
paziente (media 4,69 mesi, 8-0,25
Vmax-Vmin).
Risultati
Sono stati valutati i dati di 24 pazienti
per un totale di 26 occhi.
I valori delle PIO postoperatorie,
ai vari tempi di follow-up, sono
riportati nel grafico (Fig. 2). Si stima
una riduzione della PIO del 66% a
una settimana dall’intervento, del
41% a 3 mesi e del 39% a 8 mesi
dall’intervento.
Nella coorte, all’ultimo follow-up
per paziente (media 4,6 range
8-0,25 mesi), sono stati registrati
24/26 (92%) successi dei quali
16/26 (61%) Complete Success,
8/26 (31%) Success e 2/26 (8%)
No Success. Il decremento della
PIO è stato del 46%, con PIO media
postoperatoria di 13,50 (28-10)
mmHg. La terapia medica è stata
ridotta in 22/26 (85%) occhi, di
2,23 principi attivi (in un range da
4-0). Nel postoperatorio non è stato
necessario somministrare in nessun
caso Acetazolamide per os.
Assenti complicanze intra-operatorie
e gravi complicanze postoperatorie.
Tab. 1Caratteristiche demografiche e cliniche dei
partecipanti.
POAG, Glaucoma ad angolo aperto primario;
OAG + PEX, Glaucoma ad angolo aperto
pseudoesfoliativo; JOAG, Glaucoma ad
angolo aperto giovanile; FACO+IOL,
Facoemulsificazione e impianto di lente
intraoculare; SLT/ALT, Laser Trabeculoplastica
Selettiva/Trabeculoplastica Laser Argon;
Principi terapeutici (colliri ipotonizzanti e/o
Acetazolamide per os).
1Tab.
109
Da segnalare che in 2 casi
un'emorragia sottocongiuntivale
intraoperatoria ha portato
ad un posizionamento dello
XEN45 sottotenoniano e non
sottocongiuntivale con successivo
abbassamento della PIO più
limitato. Le lievi complicanze
postoperatorie (Tab. 2) si sono risolte
spontaneamente entro 1 settimana.
I casi di dislocazione di stent sono
stati 1/26 (4%) e i casi sottoposti a
Needling e/o 5-FU (5-Fluorouracile)
sono stati 14/26 (54%), con una
media di 1,19 (7-1) procedure per
occhio, con maggior frequenza al
quarto mese postoperatorio.
Conclusioni
I limiti del nostro studio sono le
dimensioni del campione, la durata
del follow-up, il tipo di glaucoma
non omogeneo e la valutazione
di alcuni pazienti nella curva di
apprendimento del chirurgo.
Rispetto alla letteratura, i valori medi
di PIO per tempo di follow-up sono
sovrapponibili mentre la differenza
della riduzione di PIO in % risulta
maggiore nella coorte analizzata in
questo articolo con -44% vs -31,5%
e -35% a 6 mesi postoperatori4, 5.
Il valore medio di PIO preoperatoria
nella casistica esaminata era infatti
più elevato (25,27 vs 21,40 e 23,00
mmHg di altri autori)4, 5.
Rispetto allo studio di Grover, la
nostra percentuale di Complete
Success (61% vs 45%) è
maggiore, con differenza nei
tempi medi di follow-up (4,69 vs
12 mesi)4. Si riscontra inoltre una
maggior percentuale di ipotonia
postoperatoria nel nostro studio
(19% vs 0% e 11,4%) risolta
spontaneamente entro 7 giorni4, 5.
Nella nostra casistica, il numero
di Needling e/o 5-FU (54%) è
relativamente elevato rispetto
alla letteratura dove però è stata
conteggiata unicamente la
procedura di Needling per fibrosi
(32,1% e 18,1%)4,5.
In conclusione, l’impianto di
XEN45, nella casistica descritta,
ha rappresentato una valida
alternativa chirurgica per la
riduzione della PIO in pazienti OAG.
Il mantenimento dell’integrità del
tessuto congiuntivale, l’assenza
di complicanze severe, nessuna
preclusione ad altre tecniche
chirurgiche che si rendessero
necessarie nel futuro, e l’opzione
di poter praticare la procedura in
combinazione all’asportazione
della cataratta in tempi ridotti,
rappresentano i suoi maggiori
punti di forza. Inoltre ha consentito
una veloce riabilitazione post-
operatoria e l’ottenimento di un
deflusso controllato che ha evitato
complicanze legate ad ipotalamia.
Per contro, la necessità
nell'esperienza descritta, di
Focus on...110
Fig. 2Risultati PIO (pressione intra-oculare)
postoperatori. Valori PIO postoperatori ai
diversi follow-up (1 settimana, 1, 3, 6, 8 mesi).
2Fig.
Focus on...111
una gestione della bozza con
needling e/o iniezioni di 5-FU
sottocongiuntivali ambulatoriali con
frequenza non trascurabile.
Ulteriori studi con un più lungo follow-up,
un maggior numero di partecipanti
e una più precisa indagine della
gestione postoperatoria del device
saranno necessari per chiarire meglio
gli effettivi vantaggi e svantaggi di
questa tecnica.
Gli autori del presente lavoro
dichiarano di non avere alcun
conflitto di interesse e di non avere
ricevuto compensi, finanziamenti
o altre forme di incentivazioni da
industrie produttrici di farmaci.
Bibliografia
1. Lewis RA. Ab interno approach
to the subconjunctival space
using a collagen glaucoma
stent. J Cataract Refract Surg
2014;40:1301-06
2. Caporossi A, Salgarello T,
Manganelli C. Oftalmologia. ed
Piccin, 2017, pp 232-33
3. Samples JR, Singh K, Lin SC,
et al. Laser trabeculoplasty for
open-angle glaucoma: a report
by the american academy of
ophthalmology. Ophthalmology
2011;118:2296-2302
4. Grover DS. Ab Interno Gelatin
Stent Procedure in Combination
with MMC for treatment of
Glaucoma: 12-Months Results,
in. Presented at VII World
Cornea Congress, San Diego,
CA, April 15-17, 2015
5. Stalmans I. A Minimally Invasive
Approach to Sub-conjunctival
outflow: 1 year results of an
Ab-interno Gelatin Stent for
the Treatment of Primary Open
Angle Glaucoma, in. Presented
at the International Congress
of Glaucoma Surgery, Muscat,
Oman, February 18-20, 2016
6. Cantor LB, Mantravadi A,
WuDunn D, Swamynathan
K, Cortes A. Morphologic
classification of filtering blebs
after glaucoma filtration
surgery: the Indiana Bleb
Appearance Grading Scale.
7. J Glaucoma 2003;12:266-71
Tab. 2Complicanze post-operatorie calcolate
all’ultimo follow-up (media 4.5, 8-0.25 mesi).
Ipotonia: <6 mmHg al primo giorno post-
operatorio; Bozza esuberante con H3,E3,V2;
Bozza di limitata estensione o assente con
H0,E0,V06.
2Tab.
Introduzione
La melatonina è un neuropeptide,
prodotto dalla ghiandola pineale,
ed è associata da molti anni alla
regolazione dei ritmi circadiani.
Osservata per la prima volta nel
1917, è stata isolata nel 1958
dal Dr. Aaron Bunsen Lerner,
ricercatore alla University School
of Medicine di Yale1. Da molto
tempo si conosce un aspetto
del funzionamento dell’epifisi che
la rende unica fra le ghiandole
endocrine, la sua sensibilità
alla luce; infatti la sintesi e la
secrezione della melatonina sono
fortemente influenzate dal ciclo
alternato luce e buio, attraverso
un segnale multi sinaptico che
si collega al ganglio cervicale
superiore dell’ortosimpatico.
Il ritmo circadiano è quindi
coinvolto nella secrezione di
melatonina e persiste per lungo
tempo, anche quando termina
la stimolazione luce-buio.
Attraverso questa osservazione è
stata accertata l’esistenza di un
orologio biologico (probabilmente
localizzato in una popolazione
neuronica nel nucleo sopra
chiasmatico dell’ipotalamo) in
grado di scandire i ritmi di
produzione e di rilascio della
melatonina secondo i cicli
temporali, anche in assenza
di una sincronizzazione con
le fasi di presenza e assenza
della luce solare. Durante la
fase di illuminazione diurna
la produzione e il rilascio di
melatonina si riducono, così come
il flusso di impulsi che corre
lungo l’innervazione vegetativa
dell’epifisi. Dopo il tramonto,
con l’avanzare dell’oscurità,
gli assoni del simpatico si
attivano incrementando il
rilascio di noradrenalina, che si
lega ai recettori -adrenergici
della ghiandola pineale, con
aumento della formazione di
AMP-ciclico e attivazione dei
recettori 1-adrenergici che
amplificano ulteriormente la
risposta. Il secondo messaggero
determina l’attivazione
dell’enzima arilalchilammina-N-
acetiltransferasi (AANAT) che
converte la serotonina (5-HT)
in N-acetil-serotonina, poi
metilata a melatonina dall’enzima
idrossindolo-O-metiltransferasi
(HIOMT). In tutti i mammiferi, le
informazioni fotosensoriali della
retina influenzano l’attività delle
sue proiezioni neuroniche che
vanno ad inibire o stimolare la
secrezione di melatonina.
La melatonina e i recettori
della retina
Recentemente è stata confermata
una dimostrazione diretta del
ruolo nella retina da parte della
melatonina e dei suoi recettori,
espressi nei fotorecettori
retinici sotto il diretto controllo
dell’orologio circadiano. Alcuni
studiosi del Neuroscience Institute
della Morehouse School of
Medicine di Atlanta e dell’Istituto
di Neuroscienze del CNR di Pisa
hanno mappato la distribuzione
dei recettori MT1 della
melatonina nella struttura nervosa
dell’occhio3. I ricercatori hanno
accertato che il recettore MT1 è
richiesto per la sopravvivenza di
alcuni tipi cellulari retinici e per
la modulazione della sensibilità
visiva. La presenza di un
sistema di sincronizzazione così
sofisticato suggerisce l’importanza
che riveste, per l’organismo
umano, il mantenere una serie di
funzioni ritmiche in sincronia con
l’ambiente circostante2,3.
Ad ulteriore conferma
recentemente nell’animale
da esperimento, è stata
documentata, la presenza di
un sistema in grado di fornire
all’organismo informazioni
specifiche riguardanti la
cosiddetta ritmicità circannuale
(in pratica la possibilità di
riconoscere l’alternanza delle
stagioni). Il corretto funzionamento
di tale sistema sembra dipendere
dall’interazione fra le cellule
del pace-maker endogene,
sincronizzate dalla melatonina
e le cellule ipofisarie prolattino-
secernenti3. Inoltre, è necessario
sottolineare che anche in assenza
dello stimolo luminoso la ritmicità
USO POTENZIALE DELLA MELATONINA NELLA PREVENZIONE DELLA DMLE
Massimiliano CecchiScientific Trainer - Farmigea Srl, Pisa, Italia.
Focus on...112
Focus on...113
endogena, generata a livello
del nucleo soprachiasmatico e
comunicata alla pineale, viene
conservata. Ne consegue ad
esempio che anche i soggetti
non vedenti, pur non percependo
lo stimolo luminoso e quindi
mancando del segnale più efficace
in grado di inibire la secrezione di
melatonina, dimostrano di avere
ugualmente un ritmo circadiano,
anche se spesso non del tutto
sincronizzato con l’ambiente
esterno4. A conferma della stretta
correlazione fra il ritmo della luce
e del buio e la secrezione ciclica
della melatonina, esiste tutta una
serie di evidenze sperimentali
indicanti che l’esposizione ad
una fonte luminosa di intensità
e lunghezza d’onda adeguate
durante la notte, determina una
drastica e reversibile riduzione dei
livelli di melatonina fino ai valori
diurni. Dati della letteratura sempre
più numerosi indicano infatti un
collegamento fra esposizione
alla luce durante le ore notturne,
riduzione dei livelli di melatonina e
rischio di malattia.
Relazione tra stress ossidativo,
ritmi circadiani e DMLE
L’esposizione ad agenti ossidanti,
diversamente da quanto spesso
avviene con i composti tossici,
determina, solo su una scala
temporale lunga, un danno
irreversibile. Ciò che si modifica
in maniera sorprendente è, da
un lato l'incapacità di utilizzare i
mezzi fisiologici per contrastare
efficacemente la formazione
dei radicali liberi, dall'altro
la riduzione dell'attività dei
sistemi deputati alla riparazione
dell'organismo (situazione
conosciuta come "stress
ossidativo"). Più in particolare,
durante il processo evolutivo
sono andati sviluppandosi
meccanismi intrinseci che, in
condizioni normali, si oppongono
con grande successo al
costante danneggiamento cui
siamo sottoposti a causa della
formazione dei radicali liberi e
che, nel loro complesso, vengono
denominati sistemi e/o sostanze
antiossidanti.
Con il termine Degenerazione
Maculare Legata all’Età (DMLE o
AMD dall’acronimo inglese Age-
related Macular Degeneration)
si intende un complesso di
manifestazioni cliniche a carico
1aFig.
Fig. 1Controllo della sintesi di melatonina da parte
della luce2.
Tratto retino-ipotalamico
Nucleo sopra-chiasmatico
Ipotalamo
MELATONINA
Triptofano
5-idrossitriptofanoGanglio cervicale superiore
ATP
CAMPNAT
NA
Recettore adrenergicoRecettore adrenergicoNAT – N- acetiltransferasiNA – recettore pineale noradrenergico
NA
5-idrossitriptamina
Midollo spinale
Nucleo para-ventricolare
N-acetilserotonina
Focus on...114
della regione maculare che
determinano una riduzione
dell’acuità visiva. La gravità,
l’irreversibilità, la frequenza
rendono questa patologia la causa
principale della perdita della visione
centrale (cecità) e, nei paesi
industrializzati, è la prima causa di
perdita di acuità visiva nei soggetti
di età superiore ai 50 anni5.
La patogenesi della
degenerazione maculare legata
all'età (DMLE) consiste in uno
stress ossidativo cronico, in
un maggiore accumulo di
lipofuscina nelle cellule dell'epitelio
pigmentato retinico (EPR) e
nella formazione di drusen
extracellulari, da infiammazione
cronica. La capacità di prevenire
l'accumulo di aggregati proteici
cellulari citotossici è diminuita in
cellule senescenti e può portare
all'accumulo di lipofuscina nei
lisosomi delle cellule EPR. Questa
presenza di lipofuscina riduce
l'attività dell'enzima lisosomiale
ed altera la rimozione di proteine
danneggiate dalle cellule7. Molte
reazioni di tipo ossidativo che
avvengono nell'organismo
(principalmente nei mitocondri)
generano, come sottoprodotti di
scarto, radicali liberi.
I radicali liberi causano danni alle
macromolecole (acidi nucleici,
proteine e lipidi) portando ad
invecchiamento ed a una grande
varietà di patologie degenerative
associate, DMLE compresa6.
La melatonina agisce come
scavenger di radicali liberi ed ha
la capacità di ridurre direttamente
le specie reattive dell'ossigeno
e dell’azoto, indirettamente
aumentando l'attività di difesa
antiossidante di altri sistemi
enzimatici8-9. Fattori antiossidanti
possono prevenire la DMLE e
ritardarne la progressione10-11.
Negli anziani ad esempio i ritmi
circadiani, i cambiamenti associati
all'età nel ritmo della produzione
di melatonina sono stati riscontrati
frequentemente12. È stato anche
dimostrato che l’attività del
nucleo sopra chiasmatico (NSC)
diminuisce con l'età, in particolare
nei pazienti con malattie
neurodegenerative13-14. Un calo
nella produzione di melatonina
e alterati ritmi di produzione
di melatonina possono essere
fattori che contribuiscono
all'aumento dei livelli di radicali
liberi e condurre a patologie di
tipo degenerativo11. Vi è un forte
legame tra la fisiologia oculare e
ritmi circadiani negli esseri umani.
Il rinnovo e l'eliminazione dei
vecchi fotorecettori del segmento
esterno delle cellule dal EPR è
un processo ritmico quotidiano
che è cruciale a lungo termine
per la visione. La melatonina
protegge efficacemente le cellule
dell’epitelio retinico EPR a livelli
fisiologici (10-8-10-10 M), che
possono essere raggiunti da
una somministrazione orale, a
basso dosaggio di melatonina (ad
esempio, una dose somministrata
per via orale di 3 mg di
melatonina aumenta i livelli sierici
di 2 × 10-8 M).
La somministrazione orale di
1-3 mg di melatonina per notte
è efficace nel trattamento dei
pazienti affetti da DMLE15. Ulteriori
studi hanno confermato l’attività
di scavenger della melatonina in
oftalmologia, infatti la retina è una
regione sottoposta ad intenso
flusso sanguigno dove i livelli
di ossigeno sono molto elevati.
Questa alta concentrazione di
ossigeno richiede un rigoroso
controllo redox per evitare stress
ossidativo. Anche la luce che
raggiunge la retina genera ROS
che contribuiscono al danno
ossidativo. Inoltre tutte le cellule
della retina sono ricche di
mitocondri, che sono una fonte
importante di ROS. La retina è
di per sé un organo altamente
predisposto allo stress ossidativo
a causa di intenso flusso di
sangue, elevato tasso metabolico,
la presenza di cellule ricche di
mitocondri, alte concentrazioni
di acidi grassi polinsaturi
(PUFA) facilmente ossidabili
ed esposizione prolungata alla
luce16. La melatonina controlla la
pigmentazione del tessuto retinico
e regola la luce che raggiunge
i fotorecettori, distruggendo i
radicali liberi ROS, proteggendo
così l’epitelio della retina (EPR)
dal danno ossidativo. Ristabilisce
i ritmi circadiani e l’elaborazione
del meccanismo fisiologico della
luce e del buio migliorando così
i processi di riparazione sulla
retina17.
Conclusioni
Fattori di rischio, diminuita
produzione di melatonina
endogena e carenza di
antiossidanti nella dieta possono
favorire l’insorgenza di un
importante stress ossidativo, in
grado di generare o aggravare
Focus on...115
patologie come la DMLE.
Nei paesi industrializzati questa
grave malattia, rappresenta la
maggiore causa irreversibile di
riduzione visiva e la prevenzione
resta, senza alcun dubbio, un
valido supporto nella cura delle
patologie maculari.
Gli studi AREDS (Age-Related
Eye Disease Study) hanno infatti
evidenziato l’efficacia dell’utilizzo
di antiossidanti nel ridurre il
rischio di progressione verso la
forma avanzata in pazienti con
DMLE con presenza di drusen
in entrambi gli occhi o affetti
dalla forma avanzata di DMLE in
un solo occhio.
La melatonina rappresenta una
nuova possibilità terapeutica
nella degenerazione maculare
legata all’età. Il suo profilo di
molecola endogena e la sua
forte attività antiossidante la
rendono adatta ad applicazioni
che possono rallentare il
processo di degenerazione.
Ulteriori studi sono in corso per
chiarire al meglio le funzioni
biologiche non solo nella retina
ma anche in altri tessuti della
struttura oculare.
Bibliografia
1. Lerner AB, et al. Isolation
of Melatonin and
5-Methoxyindole-3-acetic
Acid from Bovine Pineal
Glands*. The Journal of
Biological Chemistry Vol. 235,
No. 7, July 1960
2. Arendt J, et al. Melatonin and
the pineal gland: influence
on mammalian seasonal and
circadian physiology. Journals
Reproduction and Fertility.
1998;3:13-22
3. Baba K, et al. Melatonin
modulates visual function
and cell viability in the
mouse retina via the MT1
melatonin receptor. Proc Natl
Acad Sci U S A. 2009 Sep
1;106(35):15043-48
4. Liu X, et al. Diurnal
preference, sleep habits,
circadian sleep propensity
and melatonin rhythm in
healthy human subjects.
Neuroscience Letters 2000
Feb. 25;280(3):199-202
5. Font: American Academy of
Ophthalmology
6. Anisimov VN, et al. Melatonin
as antioxidant, geroprotector
and anticarcinogen. Biochim
Biophys Acta. 2006 May-
Jun;1757(5-6):573-89. Epub
2006 Apr 17
7. Kaarniranta K, et al.
Autophagy regulates death
of retinal pigment epithelium
cells in age-related macular
degeneration. Cell Biol
Toxicol 2017;33:113-28
8. Reiter RJ, et al. Biochemical
reactivity of melatonin with
reactive oxygen and nitrogen
species: a review of the
evidence. Cell Biochem
Biophys. 2001;34(2):237-56
9. Cagnoli CM, et al. Melatonin
protects neurons from
singlet oxygen-induced
apoptosis. J Pineal Res 1995
May;18(4):222-26
10. Stefanova NA, et al. Potential
of melatonin for prevention
of age-related macular
degeneration: experimental
study. Adv Gerontol
2013;26(1):122-29
11. Fanjul-Moles ML, et al.
Relationship between
Oxidative Stress, Circadian
Rhythms, and AMD.
Oxid Med Cell Longev
2016;2016:7420637
12. Skene DJ, et al. Melatonin
rhythmicity: effect of age
and Alzheimer's disease.
Exp Gerontol 2003 Jan-
Feb;38(1-2):199-206
13. Pandi-Perumal SR, et al.
Senescence, sleep, and
circadian rhythms. Ageing
Res Rev 2002 Jun;1(3):559-
604
14. Wu YH, et al. Disturbance
and strategies for reactivation
of the circadian rhythm
system in aging and
Alzheimer's disease. Sleep
Medicine 2007 Sep;8(6):623-
36. Epub 2007 Mar 26
15. Rosen RB, et al. Effects of
melatonin and its receptor
antagonist on retinal pigment
epithelial cells against
hydrogen peroxide damage.
Molecular Vision 2012
June;18:1640-48
16. Blasiak, J et al. Melatonin
in Retinal Physiology and
Pathology: The Case of
Age-Related Macular
Degeneration. Oxid Med Cell
Longev 2016;2016:6819736.
Epub 2016 Sep 5
17. Changxian, YI et al. c Acad
Sci 2005;1057:384-92
116
news dalle aziende116
news dalle aziendeLAMPADA A FESSURA CONNUOVO SISTEMA DIGITALE
La lampada a fessura Takagi 700GL è ora disponibile con un nuovo sistema digitale per l’acquisizione e il
salvataggio delle immagini.
Il nuovo software di acquisizione è
stato migliorato e reso più efficiente,
diventando un ulteriore elemento
di spicco della lampada Takagi, già
molto performante.
La lampada a fessura 700GL è
caratterizzata da 5 ingrandimenti
e da un’illuminazione a LED
innovativa costituita da un unico
LED (da 3 watt) in grado di garantire
una sorprendente uniformità di
illuminazione dell’occhio. Inoltre, è
inserito un sistema di fibra ottica
a LED integrato (background
d’illuminazione), indipendente e
dimabile direttamente da reostato
posto sulla base. Il diametro
massimo dello spot d’illuminazione
può essere aumentato fino a 14 mm,
funzionalità utile per l’applicazione
di lenti sclerali. Grazie ad un design
moderno, questa lampada appare
molto compatta ed accattivante,
integrando al proprio interno tutti i
cavi di connessione.
Le ottiche della lampada
garantiscono una profondità di
campo eccellente, e con la versione
digitale è possibile visualizzare
e salvare le immagini sul proprio
computer tramite una telecamera
USB 3.0 da 10 Megapixel.
Il nuovo software di acquisizione
della telecamera, completamente
rinnovato, garantisce un’eccellente
qualità delle immagini, permettendo
di visualizzare e analizzare in
modo molto definito perfino i più
piccoli dettagli. Grazie al preciso
bilanciamento dei colori ed all’utilizzo
di un nuovo driver sviluppato ad hoc,
è possibile acquisire foto e video
di alta qualità e con colori realistici.
Inoltre, la velocità e la fluidità di
acquisizione sono state ulteriormente
migliorate e, con l’utilizzo di un frame
rate di 28fps, la visualizzazione
a video segue perfettamente
quella reale, semplificando il lavoro
dell’utilizzatore.
Al sistema digitale di questa lampada
può inoltre essere aggiunto il software
ENDOKER (patent pending), il
rivoluzionario sistema integrato
che sostituisce completamente
la necessità di un microscopio
endoteliale. Endoker permette di
eseguire la valutazione e l’analisi
delle cellule endoteliali utilizzando la
lampada a fessura e, per molti versi,
migliora le funzionalità fino ad oggi
riservate ad uno strumento dedicato
e indipendente. Endoker permette
l’agevole acquisizione in tempo
reale di un’immagine fotografica
relativamente ampia dell’endotelio
corneale nell’area specifica di
interesse, ne elabora il contenuto e
fornisce forma e densità delle cellule
endoteliali analizzate, inclusi i relativi
parametri statistici. Questo sistema
rappresenta uno dei risultati concreti
della ricerca in questo settore avviata
presso l’Università di Milano Bicocca
e del conseguente processo di
trasferimento tecnologico.
Il sistema rappresenta il primo passo
verso un futuro con la lampada a
fessura come strumento centrale
e compatto, con le funzioni oggi
ottenibili solamente con strumenti
singoli, dedicati e indipendenti l’uno
dall’altro.
Per maggiori informazioni, contattare
Frastema Ophthalmics Srl
Tel. 0331 342008 - [email protected]
cidi
117
news dalle aziendeLA SOLUZIONE NANOTECNOLOGICA PER RIDURRE IL DISCOMFORT DEL PAZIENTE ALLERGICO
Per la loro potente azione
antiossidante, intervengono
indirettamente sul processo flogistico
migliorando a livello oculare e
perioculare la sintomatologia
associata a stati infiammatori.
La vitamina E risulta avere una
attività antiossidante, antiapoptotica
e, quindi, epitelioprotettrice.
La vitamina A ha un effetto
antiossidante, riepitelizzante e
favorisce la produzione di una
mucina (MUC16), importante
elemento per la bagnabilità della
superficie oculare. Gli aminoacidi
L-prolina, L-glicina, L-lisina e
L-leucina sono aminoacidi essenziali
comunemente presenti nel film
lacrimale. Sono substrati
fondamentali nei processi di sintesi
proteica, necessari al metabolismo
cellulare ed alla sintesi della matrice
extracellulare, in cui le cellule
migrano e si differenziano. È stato
recentemente dimostrato che,
se somministrati per via topica,
contribuiscono ad aumentare la
lubrificazione della superficie oculare
e, attraverso il mantenimento
dell’omeostasi tissutale, a favorire i
fenomeni di riepitelizzazione.
Lacrisek® Plus è presente in collirio
multidose (Lacrisek® ofta Plus),
collirio in contenitori monodose
(Lacrisek® ofta Plus monodose)
ed in forma spray: l'innovativa
formulazione spray (Lacrisek® Plus
Spray) può aiutare a ridurre l’edema
palpebrale spesso associato a
congiuntivite allergica.
L’occhio è il sito bersaglio più
comune per lo sviluppo di un
disturbo allergico dovuto alla risposta
infiammatoria della congiuntiva a
fattori ambientali di varia natura quali
polline, muffe, acari, etc.
La congiuntivite allergica, spesso
associata a rinite, risulta essere una
delle manifestazioni più frequenti
di ipersensibilità a livello oculare
e colpisce circa il 30% della
popolazione occidentale con una
prevalenza in forte aumento negli
ultimi anni.
I mastociti e i basofili rappresentano le
cellule cardine della reazione allergica
nella quale si distinguono due fasi:
La fase immediata corrispondente
alla forma acuta scatenata
dall’ingresso di una considerevole
quantità di allergene nel sacco
congiuntivale che provoca il rilascio di
istamina, leucotrieni, prostaglandine
ed altri mediatori della flogosi.
Questa reazione è caratterizzata
clinicamente da edema e iperemia
della congiuntiva e della palpebra
ed è associata ad intenso prurito e
lacrimazione.
La fase tardiva insorge a distanza di
ore dall’esposizione allergenica ed ha
un decorso prolungato e multifasico.
Questa reazione è correlata
all’infiammazione tissutale ed è
caratterizzata dal danno alle cellule
epiteliali delle mucose, sostenuto
dall'infiltrazione nei tessuti da parte di
eosinofili, neutrofili, basofili, monociti
e cellule T CD4+. Le citochine sono
prodotte soprattutto in risposta al
riconoscimento specifico dell’antigene
estraneo e svolgono un’azione
di attivazione e regolazione delle
cellule infiammatorie quali fagociti
mononucleati, neutrofili ed eosinofili.
I colliri a base di cortisone possono
contribuire a ridurre i sintomi
cronici della congiuntivite allergica
poiché prevengono la fase tardiva,
inoltre inibiscono la produzione di
istamina e dei mediatori della flogosi.
Tuttavia, la terapia non può essere
prolungata per un lungo periodo
per evitare la possibile comparsa
di effetti collaterali.
Al fine di ridurre il discomfort del
paziente allergico può essere utile
un trattamento con una soluzione
oftalmica a base di liposomi,
vitamina A, vitamina E ed aminoacidi
(Lacrisek® ofta Plus, Lacrisek® ofta
Plus monodose, Lacrisek® Plus
Spray).
Il liposoma è una microvescicola
(nanoparticella) tondeggiante
costituita da un doppio strato di
lipidi (fosfolipidi) e contenente al
suo interno una soluzione acquosa.
I fosfolipidi sono definibili come
lipidi naturali in grado di risanare
ed implementare il deficit lipidico
e di ripristinare il normale equilibrio
omeostatico della superficie oculare
e del film lacrimale che in corso
di congiuntivite allergica risulta
alterato.
Le vitamine A ed E, vengono
veicolate dai liposomi e
svolgono la loro funzione
terapeutica sulla rima palpebrale
e sulla superficie corneale.
di
LL
G
P
LL
G
P
LL
G
P
LL
G
PLL
G
P
LLLLLLLL
GGGGG
PPP
LL
G
P
LL
G
P
LL
G
P
LL
G
P
LIPOSOMA
LL
G
P
LL
G
P
LP
LL
G
P
LL
G
P
STRATO LIPIDICO
STRATO ACQUOSO
CELLULE EPITELIALI
news dalle aziende118
news dalle aziendeDR-900 DA SHIN NIPPONLA PERFEZIONE DELL’ANALISI VISIVACON UN TOCCO
un semplice touch per far capire
all’esaminato le differenze di visone.
La tavola dei test per vicino è fornita
nel set standard ed è dotata di un
sistema di illuminazione automatica
a LED. La stampante è posta dietro il
pannello comandi e ha un sistema di
taglio automatico della carta. Con gli
strumenti Shin Nippon l’esame della
vista unisce la rapidità del test alla sua
stessa precisione ed accuratezza.
Per informazioni contattare il numero 0521 64 21 26 oppure visitare il sito Polyoftalmica www.polynew.it per conoscere i dettagli e la scheda tecnica del prodotto.
Il forottero computerizzato di Shin Nippon, interfacciandosi a tutti gli altri strumenti dello studio, è il necessario supporto tecnologico per condurre un accurato esame della vista con dei semplici comandi touch screen.
Il forottero è uno strumento
indispensabile per chi vuole condurre
un esame refrattivo velocemente e
con precisione, sollevando il paziente
dal peso della montatura di prova.
Il DR-900 rivoluziona l’andamento
quotidiano dello studio; in pochi
semplici step, è possibile effettuare un
esame di accuratezza assoluta e senza
errori. Il forottero computerizzato Shin
Nippon si caratterizza per un pannello
comandi touch screen dall’interfaccia
semplicissima al fine di permettere
all’operatore interventi facili e veloci.
La tecnologia di ultima generazione e
l’esperienza Shin Nippon permettono
un cambio di lenti ultra rapido e
silenzioso.
L’esame è totalmente gestito dal
pannello comandi centrale, che riceve
i dati da tutti gli strumenti refrattivi
dello studio (Autorefrattometro,
Frontifocometro, Monitor o Proiettore
di ottotipi e Forottero). Il pannello
comandi è dotato di una tastiera
ergonomica con manopola di
navigazione, che insieme al monitor
da 10.4 pollici touch-screen, permette
di accedere a tutte le funzioni del
forottero e degli altri strumenti ad esso
collegati. I movimenti del forottero
sono estremamente veloci e silenziosi.
I dati provenienti dall’autorefrattometro
e dal frontifocometro possono
essere richiamati in tempo reale con
un semplice touch, per permettere
all’esaminato una comparazione
immediata tra la visione con la
vecchia e la nuova correzione. Anche
il monitor di ottotipi Shin Nippon o il
proiettore CP-500 possono essere
comandati dalla console del forottero
con connessione wireless. È possibile
programmare una sequenza di ottotipi,
e scegliere alcune lenti specifiche
o filtri da inserire nel forottero alla
presentazione di un determinato test.
Tutto è personalizzabile nel minimo
dettaglio, al fine di rendere l’esame
veloce e preciso. Le lenti del forottero
DR-900 hanno un diametro tra i più
ampi del mercato e il design dello
strumento permette un campo visivo
di ben 40°, un dato importante che
permette precisione nell’esame.
La memoria interna permette di salvare
fino a 5 diversi dati di refrazione,
che possono essere richiamati con
119
news dalle aziendePOCHE GOCCE PER UN SOLLIEVO IMMEDIATO
pensata per una terapia topica in
grado di allontanare in tempi brevi
i sintomi legati a fattori atmosferici
(sole, vento, smog) o ambientali
(fumo, schermi luminosi, lampade
abbronzanti), al contatto con corpi
estranei (polvere, sostanze irritanti,
oggetti) e alle allergie stagionali.
Visustrin Gocce Oculari è un valido
supporto per contrastare gli effetti
di un uso eccessivo di computer
e smartphone o dell’esposizione
prolungata alla luce solare e
artificiale, ma anche per alleviare
i postumi da chirurgia rifrattiva e
per tamponare i fastidi derivanti
da sindrome dell’occhio secco:
una patologia oculare che, oltre i
50 anni di età, colpisce una quota
sensibile di popolazione (5-35%)
con un’incidenza maggiore nel
genere femminile a causa delle
oscillazioni ormonali tipiche della
menopausa.
Visustrin Gocce Oculari non
richiede prescrizione medica e il
sollievo derivante dal suo utilizzo
dovrebbe essere immediato e
portare a un miglioramento tangibile
e progressivo del fastidio entro 2-3
giorni. Qualora non si avvertisse
beneficio entro le 48 ore, o se
dovessero subentrare sintomi di
diversa natura, è consigliato il
consulto di uno specialista per
escludere patologie più serie.
Le Gocce Oculari non alterano
le facoltà visive e non offuscano
la nitidezza nella percezione
delle immagini: per questo non
interferiscono in alcun modo con
la capacità di guidare veicoli o
sull’utilizzo di macchinari in piena
sicurezza.
Visustrin® Collirio e Visustrin®
Gocce Oculari sono prodotti di
Pietrasanta Pharma S.p.A.
via S. Francesco, 67
55049 Viareggio (LU)
www.pietrasantapharma.it
Che si tratti di un granellino di
sabbia sollevato dalla brezza
estiva o dei primi venti autunnali,
delle gelide raffiche dell’inverno
o dei pollini primaverili, non c’è
stagione in cui gli occhi non
abbiano bisogno di un prezioso
alleato per mantenere il corretto
grado di umidità e idratazione e
lenire arrossamenti e pruriti.
Per questo Pietrasanta Pharma,
storica casa farmaceutica con
sede a Viareggio, ha voluto
ampliare la propria linea di
supporto alle difese dell’occhio
affiancando al farmaco da
banco Visustrin Collirio il nuovo
dispositivo medico Visustrin
Gocce Oculari.
Basta un ciglio, un po’ di trucco,
l’aria condizionata o qualche ora
di troppo al pc o con le lenti
a contatto per ritrovarsi con gli
occhi rossi, gonfi, secchi o, al
contrario, soggetti a lacrimazione
eccessiva. In assenza di patologie
particolari che richiedano una
specifica terapia oftalmica,
l’utilizzo di pratiche gocce oculari
può rappresentare la soluzione
immediata per i piccoli e grandi
problemi che affliggono uno degli
organi più delicati e importanti del
nostro corpo.
L’innovativo prodotto Visustrin
Gocce Oculari risolve rapidamente
questi e altri disturbi comuni
grazie all’efficacia dei suoi
principi attivi. L’estratto secco di
Perilla allo 0,1% e la medesima
concentrazione del Sodio
Ialuronato contenuti nel dispositivo
medico di classe II, venduto
esclusivamente in farmacia in
confezione da dieci pratiche fiale
monodose, inibiscono invece
l’azione dei radicali liberi e hanno
proprietà lubrificanti e umettanti.
La sinergia delle due sostanze
- la Perilla con il suo elevato
contenuto di polifenoli e il Sodio
Ialuronato, polimero polisaccaride
a notevole biocompatibilità - unita
alla particolare composizione
quali-quantitativa, senza OGM né
ingredienti di origine animale, è in
grado di determinare un’azione
antiossidante, rinfrescante e
diluente.
Grazie alle particolari caratteristiche
dei componenti la formula del
nuovo prodotto Visustrin si
presenta ad elevato comfort e
generalmente ben tollerata: le
gocce risultano di sicuro utilizzo
anche contestualmente all’uso
di lenti a contatto, riducendone
il fastidio con una rapida
azione antiossidante che allevia
arrossamento, secchezza e
affaticamento.
Specificamente indicato in caso di
secchezza oculare, affaticamento,
stress visivo e fastidio da LAC
(lenti a contatto), Visustrin Gocce
Oculari è una soluzione oculare
dalle proprietà decongestionanti
PIETRASANTA PHARMA S.p.A.
news dalle aziendeINTRAVIT: INTEGRATORE ALIMENTARE
parzialmente la sintesi dei VEGF,
dei VEGFR, delle Metalloproteasi
(MMP2 e MMP9) e delle integrine
3, tutti fattori coinvolti nel
processo angiogenetico.
La curcumina è il principale
componente biologicamente
attivo della Curcuma.
La curcumina si è dimostrata
capace di contrastare i
processi flogistici in vari distretti
oltre ad agire sulla riduzione
dell’angiogenesi.
Bromelina è in realtà un termine
generico che si riferisce a due
enzimi proteolitici individuati
in Ananas comosus pianta
appartenente alla famiglia delle
Bromeliaceae, da cui il nome.
La bromelina, per la sua
attività proteolitica, si è
dimostrata capace di favorire il
riassorbimento degli edemi e la
riduzione dei fenomeni flogistici.
La piperina è un alcaloide
responsabile del sapore
pungente del Piper nigrum (pepe
nero) e Piper longum (pepe
lungo). Piante appartenenti alla
famiglia delle Piperaceae.
La piperina si è dimostrata
capace di contrastare i
processi flogistici e di favorire la
biodisponibilità di alcuni estratti
naturali come ad esempio la
curcumina
Compliance del pazienteLe dimensioni delle compresse,
la posologia, il numero di
compresse per confezione e la
tollerabilità, possono costituire
fattori limitanti per la compliance
del paziente alla terapia prescritta.
È per questa ragione che
INTRAVIT è stato pensato in
modo da offrire al paziente:
• compresse di facile deglutizione
grazie alle dimensioni ridotte
• modularità posologica 1 o 2
compresse die
• confezione da 30 compresse
• tollerabilità ottimale
INTRAVIT, quindi, è stato strutturato per essere un supporto razionale alle terapie dell’edema retinico e al trattamento con iniezioni intravitreali tenendo nella massima considerazione le esigenze del paziente.
INTRAVIT è un prodotto che
nasce con l’obiettivo di rispondere
in maniera semplice e concreta
alle esigenze dei pazienti
sottoposti a trattamento con
intravitreali o affetti da edema
retinico.
La formulazione di INTRAVIT
è stata pensata per essere
razionale e spiccatamente mirata
all’obiettivo che è quello di
combattere:
• L’infiammazione
• La neo angiogenesi
• L’edema
La composizione di INTRAVIT
è stata quindi strutturata
con quattro componenti che
rispondono a tali prospettive:
• Artemisia dracunculus
(artemisinina) estratto secco
come antiangiogenetico
• Curcuma longa (curcumina)
estratto secco titolato al
95% in curcumina come
antinfiammatorio, antiossidante e
neuro protettore
• Ananas comosus (bromelina)
come antiedemigeno
• Piper nigrum (piperina) come
antiossidante e per favorire
l’assorbimento della curcumina.
Artemisinina è una molecola
estratta da varie specie di
Artemisia; l’artemisinina e i suoi
derivati sono farmaci antimalarici
ben noti.
Nel 2015 è stato assegnato il
premio Nobel per la medicina
alla dottoressa cinese Tu Youyou
per la ricerca sull’utilità dell’utilizzo
dell’artemisinina nella lotta alla
malaria.
Negli ultimi anni, però, è stata
riportata l'attività antitumorale
dell’artemisinina correlata alla sua
attività anti-angiogenetica.
L’attività anti-angiogenetica
dell’artemisinina e dei suoi derivati
è correlabile alla capacità di inibire
news dalle aziende120
news dalle aziende
news dalle aziende122
LACTOYAL® COLLIRIO:IL RIMEDIO PER LA SENESCENZA DEL“SISTEMA LACRIMA-SUPERFICIE OCULARE”
Quando si parla di invecchiamento
della popolazione è utile
evidenziare che, secondo le
più recenti fonti demografiche
(Ageing Society- Osservatorio
sulla terza età), “non solo l'età
media della popolazione è
aumentata negli ultimi decenni
in modo straordinario, ma
anche le previsioni di autorevoli
organismi internazionali per i
prossimi decenni confermano
questa tendenza. Secondo le
proiezioni delle Nazioni Unite,
infatti, nel 2050 l'età media a livello
planetario sarà di 38 anni, mentre
nel 1990 era di 26 anni. Si tratta
di un fenomeno unico nella
storia dell'umanità, di notevole
rilevanza. L'Europa è il continente
che detiene il primato dell'età
media più alta: già nel 1990 era di
37 anni, mentre nel 2050 l'ONU
prevede che sarà di 47 anni”.
Alla luce di una società
sempre più “matura” e, di
conseguenza, sempre più
attenta al mantenimento delle
performance a partire da questa
fase centrale della vita, OOGroup
in questi ultimi anni ha rivolto la
propria ricerca al “trattamento e rallentamento” delle patologie oculari strettamente correlate all’invecchiamento delle diverse strutture dell’occhio.La linea SOOFT nello specifico, ha
da poco immesso in commercio
LACTOYAL®collirio, un sostituto
lacrimale innovativo a base di
ACIDO LATTOBIONICO al 4%
e di Acido Ialuronico allo 0,15%
in grado di RIEQUILIBRARE
lo squilibrio ossidativo, quello
delle difese antimicrobiche e
di controllare l’infiammazione
nell’occhio secco correlato all’età (Age Related Dry Eye).L’età infatti è una delle
principali cause endogene che
maggiormente incidono sulla
frequenza della secchezza oculare.
Nel mondo occidentale circa
il 5-30% degli anziani soffre di
secchezza oculare, di cui l’8,4%
sotto i 60 anni, il 15% tra i 70 e i 79
anni e il 20% con un’età maggiore
degli 80 anni, con maggiore
prevalenza delle donne rispetto
agli uomini. La predisposizione
alla secchezza oculare degli
anziani è dovuta ai fenomeni di
invecchiamento delle palpebre,
aumentato uso di farmaci sia
sistemici che topici (occhio secco
IATROGENO), aumento degli stati
infiammatori (malattie autoimmuni,
sindrome di Sjögren, artrite
reumatoide…), stress ossidativo
caratteristico dell’avanzare dell’età,
cambiamenti ormonali e patologie
neurologiche.
Il mal posizionamento della
palpebra, la minore frequenza
di ammiccamento, la rosacea,
le disfunzioni delle ghiandole
di Meibomio (cheratinizzazione
e occlusione delle ghiandole
secretorie o MGD), l’infiammazione
e le fibrosi delle ghiandole lacrimali,
sono associate frequentemente
ad un aumento dell’evaporazione
delle lacrime, causa dell’occhio
secco nell’anziano. Inoltre,
la diminuzione degli ormoni
sessuali che si registra durante
la menopausa e l’andropausa,
determina un'alterata produzione
di sostanze lipidiche da parte delle
ghiandole di Meibomio.
Il film lacrimale dell’anziano
inoltre è caratterizzato da una
riduzione della concentrazione di
LATTOFERRINA, glicoproteina
fondamentale ad azione
antiinfiammatoria (favorisce
la proliferazione dei linfociti
ed aumenta la citotossicità di
monociti e cellule natural killer),
antimicrobica ed antiossidante.
L’azione antiossidante e
antimicrobica sono dovute alla
capacità chelante verso il Ferro.
In virtù dell’elevata capacità
chelante per il ferro e delle proprietà
antiossidanti ed antiinfiammatorie,
l’acido lattobionico costituisce un ideale mimetico FUNZIONALE della lattoferrina.L’acido lattobionico è un derivato
disaccaridico formato dall’unione di
galattosio ed acido gluconico.
Questa molecola presenta
diverse proprietà benefiche
per la secchezza oculare,
tra cui un’elevata capacità
IDRATANTE e PROTETTIVA,
un’azione ANTIOSSIDANTE
dovuta alla chelazione del
FERRO, promuove la sintesi
dei componenti della matrice
extracellulare come il collagene
e i glicosaminoglicani a livello
dello stroma corneale, possiede
PROPRIETÀ ANTINFIAMMATORIE.
Inoltre, in virtù del mimetismo
con la lattoferina ha dimostrato
di possedere proprietà
antimicrobiche in vitro su ceppi
Gram positivi e Gram negativi.
L’acido lattobionico è un efficace
inibitore delle metalloproteasi
(MMPs), responsabili
(in particolar modo la MMP-9)
della degradazione tissutale
propria dei processi infiammatori.
Quest’azione è stata dimostrata
su modelli sperimentali di
scarificazione corneale nel coniglio.
Lactoyal collirio si candida quindi
ad essere il primo sostituto
lacrimale specificatamente indicato
nell’AGE RELATED DRY EYE.
124124
news dalle aziende
Visufarma S.p.A. informa i Signori
medici oculisti che ha introdotto
nel mercato oftalmico un collirio
a base di Acido Ialuronico Cross-
linkato, Coenzima Q10 e Vitamina
E TPGS dal nome commerciale
VisuXL.
VisuXL rappresenta l'ultima innovazione nel trattamento della superficie oculare danneggiata. L'innovazione è testimoniata da
una doppia tutela brevettuale,
italiana EU e USA.
VisuXL garantisce un rapido ripristino dell'integrità della superficie oculare danneggiata donando al paziente sollievo e comfort prolungati nel tempo.
Tutto questo è ottenuto grazie
all'azione riepitelizzante e di
rigenerazione del plesso sub
basale corneale del Coenzima
Q10 unito all'azione lubrificante,
idratante e viscosizzante di
lunga durata dell'acido ialuronico
cross-linkato.
L'acido Ialuronico cross-linkato rappresenta l'ultima novità in tema di acido ialuronico. La molecola ha una consolidata
esperienza in dermatologia,
utilizzata nei filler dermici e
sottocutanei ha un tempo
di permanenza superiore
all'acido ialuronico lineare e in
ortopedia dove viene utilizzata
come viscosupplementazione
nelle infiltrazioni articolari del
ginocchio in quanto in grado di
ridurre il dolore con un minore
numero d'infiltrazioni rispetto alla
forma lineare.
La Vitamina E TPGS deriva
dall'esterificazione della Vitamina
E con il polietilenglicole 1000
succinato, veicolo che ha
permesso di solubilizzare il
Coenzima Q10.
VisuXL è un medical device di
classe II b in confezione multidose
senza conservanti da 10 ml.
La goccia calibrata da 30 μl e la
sterilità garantita due mesi dopo la
prima apertura garantiscono l'uso
del prodotto sia in acuto che per
tempi più prolungati.
VisuXL favorisce i processi
riparativi della superficie oculare
danneggiata in caso di:
• Chirurgia del segmento anteriore
• Ulcere, cheratiti e traumi
• Dry eye e LAC.
L'acido ialuronico cross-linkato
rappresenta oggi una grande
opportunità in oftalmologia perché
è un prodotto che conserva tutte
le proprietà dell'acido ialuronico
lineare con caratteristiche
strutturali di maggiore stabilità e
un tempo di permanenza a livello
corneo congiuntivale superiore
all'acido ialuronico lineare.
L'acido ialuronico cross-linkato
grazie alla sua struttura reticolare
presenta una stabilità del
parametro viscosità superiore
all'acido ialuronico lineare e viene
degradato più lentamente dalla
ialuronidasi corneali, tale struttura
consente inoltre un aumento
del tempo di permanenza del
Coenzima Q10 sulla superficie
oculare.
Il Coenzima Q10 è un
antiossidante endogeno, che
esplica 3 importanti azioni:
azione Bioenergetica, favorisce
la sintesi di ATP, molecola
indispensabile durante i processi
di riparazione della superficie
oculare (Mencucci R, et al. IOVS
2014,55:7266-71; Fogagnolo P, et
al. Ophthalmologica 2013,229:26-
31) ha un'attività antiapoptotica
su cheratociti e fibroblasti
corneali (Chen C, et al. PloS
ONE 2011,6), ed infine un'azione
antinfiammatoria.
È stato dimostrato il suo
coinvolgimento nell'inibizione
dell'espressione di geni che
sintetizzano molecole pro-
infiammatorie come il TNF- ,
attraverso inbizione dell'NF-kB
(Schelmelzer C, et al. BioFactors
2008;32:179-83).
VISUXL “L'INNOVAZIONE NEL TRATTAMENTO DELLA SUPERFICIE OCULARE DANNEGGIATA”
124
125125
L’INNOVAZIONE NEL TRATTAMENTO DELLA
SUPERFICIE OCULARE DANNEGGIATANEL TRATAA TAMENTT TO DELLA
SUPERFICIE OCULARE DANNEGGIATAA ATT
ACCELERA I PROCESSI RIPARATIVI DEGLI EPITELI DANNEGGIATI
FAVORISCE LA RIGENERAZIONE DEL PLESSO SUB-BASALE CORNEALE
LUBRIFICA E IDRATA A LUNGO LA SUPERFICIE OCULARE
DOPPIO
BREVETTO
LE
MULTIDOSE SENZA CONSERVANTI DA 10 mlDISPOSITIVO MEDICO DI CLASSE II B
news dalle aziende126
IL PUNTO DI VISTA DEL P.I.C.A.S.S.O. SUL PAZIENTE CON DISFUNZIONE LACRIMALE
P.I.C.A.S.S.O.*, chi è costui? È un gruppo di esperti italiani
che si propone di mettere nelle
mani degli specialisti oftalmologi
strumenti unici - difficilmente
esistenti in letteratura - ma
soprattutto pratici, per giungere a
un corretto approccio diagnostico
e terapeutico del paziente con
disfunzione lacrimale. Il tutto nei
tempi di visita a disposizione.
Di quali strumenti si parla?
Il “metodo del 1-2-3”, per fare la diagnosi in tempi
ragionevoli, la riclassificazione dei
fattori di rischio, il “metodo 3+2”, per impostare una terapia a 360°,
sempre con un occhio di riguardo
per il counseling al paziente, per
avere la massima collaborazione e
soddisfazione.
Il frutto del loro lavoro è da oggi
disponibile. Si tratta delle prime
“Raccomandazioni Italiane per
la gestione del paziente con
disfunzione lacrimale”, documento
realizzato con il contributo
incondizionato di Thea Farma.
Théa è, da sempre, impegnata
nel trattamento della disfunzione
lacrimale e collabora con i
professionisti coinvolti nel
trattamento del paziente con
disfunzione lacrimale per
offrire efficacia, tollerabilità
e accessibilità del sostituto
lacrimale.
Con questo spirito è nato
THEALOZ DUO, unico nella
sua composizione, con oltre 30
studi a supporto di efficacia e
tollerabilità.
THEALOZ DUO è la lacrima ad ampio spettro che, in una sola
goccia, combina l’azione idratante
e lubrificante dell’acido ialuronico
all’azione di bioprotezione
sull’epitelio del trealosio.
validità di tre mesi dopo apertura
grazie alla tecnologia ABAK®.
Quali i risultati? Aumento dello
spessore del film lacrimale fino a 4
ore, sollievo prolungato nel tempo,
normalizzazione dell’albumina
sierica nelle lacrime e soprattutto
soddisfazione per il paziente!
THEALOZ DUO è raccomandato
dal gruppo P.I.C.A.S.S.O.!
CARTA DI IDENTITÀ Cognome e Nome THEALOZ DUO NATO IL 01/01/2013 in Laboratoires Théa PROFESSIONE La lacrima ad ampio spettro SEGNI PARTICOLARI Associazione tra acido ialuronico 0,15% (sintomatico) e trealosio 3% (curativo) in soluzione ipotonica Tecnologia by Théa Sistema brevettato ABAK® senza conservanti, sterilità garantita per 3 mesi
*Il gruppo P.I.C.A.S.S.O. è composto da: Prof. Pasquale Aragona, Prof. Ordinario
di Oftalmologia, Dipartimento delle Scienze Biomediche – Università di Messina;
Dr.ssa Emilia Cantera, Responsabile del Servizio di Chirurgia Refrattiva, Ospedale
Israelitico, Roma; Prof.ssa Rita Mencucci, Clinica Oculistica di Firenze; Prof.
Maurizio Rolando, Centro Superficie Oculare, IsPre Oftalmica, Genova; Dr.ssa
Pierangela Rubino Dirigente Medico, AOU di Parma.
Bibliografia: Foglietto illustrativo Thealoz Duo • Fukuda K et al. Hyaluronic acid in tear fluid and its synthesis by corneal epithelial cells. Asia Pacific J Ophthalmol 1998;40:62-5 • JC Pinto-Bonilla et al. A randomized crossover study comparing trehalose/hyaluronate eyedrops and standard treatment: patient satisfaction in the treatment of dry eye syndrome. Ther Clin Risk Manag. 2015;11:595-603 • Matsuo T. Trehalose versus Hyaluronan or Cellulose in Eyedrops for the Treatment of Dry Eye. Japanese Ophthalmological Society 2004 • Report of the Dry Eye WorkShop. Ocul Surf 2007;5(2): 65-204 • Rolando M. et al The correct diagnosis and therapeutic management of tear dysfunction: recommendations of the P.I.C.A.S.S.O. board. Int Ophthalmol DOI 10.1007/s10792-017-0524-4 • Schmidl D et al. Tear film thickness after treatment with artificial tears in patients with moderate dry eye disease. Cornea. 2015 Apr;34(4):421-6. doi: 10.1097/ICO.0000000000000358 • Uchida K et al. Activation of Master Autophagy Regulator TFEB During Systemic LPS Administration in the Cornea. J Toxicol Pathol 2014;27:153-58 • Versura P. Densità delle cellule mucipare: un fattore da monitorare nel trattamento del dry-eye. SOI 2012
Il trealosio è una molecola ad oggi
conosciuta anche come induttore
dell’autofagia, meccanismo di
mantenimento dell’omeostasi
cellulare, sui quali studi è stato
assegnato il premio Nobel per
la Medicina 2016 al giapponese
Yoshinori Ohsumi.
THEALOZ DUO è senza
conservanti, senza fosfati ed ha una
news dalle aziende127
LA LACRIMAAD AMPIO SPETTROPER TUTTI I PAZIENTICON DISFUNZIONELACRIMALE
DEDUCIBILE
FISCALMENTEDEDUCIBILE
FISCALMENTE
%0CONSE
RVANTI
300 gocce senza conservantein soluzione ipotonica
Sterilità garantita fino a 3 mesi
Compatibile con LaC
128
calendario eventi
8-9 SETTEMBRE 2017
LondraEGS Members’ Meeting 2017
Segr. Organizz.: OICTel. + 39 055 [email protected]
14-16 SETTEMBRE 2017
Chieti, Auditorium del Rettorato Campus UniversitàXIII Corso Nazionale “Società
Oftalmologi Universitari - SOU
Segr. Organizz.:Formazione ed Eventi S.r.l.Tel. +39 06 [email protected]
15 SETTEMBRE 2017
Cremona, Palazzo TrecchiNovità in tema di chirurgia
delle vie lacrimali ed
oftalmoplastica funzionale e
ricostruttiva
Presidente del Corso: N. di GiacomoOrganizzatore e segreteria scientifica: Maurizio CarraiSegr. Organizz.: Across EventsTel. +39 0382 [email protected]
15 SETTEMBRE 2017
Bassano del Grappa (VI)New trends in Eye Cancer
Research and Treatment
Corsi oftalmologici bassanesi
– Controversie del femto laser
nella chirurgia della cataratta
Organizz.: S. MorselliSegr. Organizz.:UNIKA CONFERENCES&EVENTS SrlTel. +39 0544 [email protected]
12-13 OTTOBRE 2017
RomaXX Congresso Nazionale SIOL
(Società Italiana di Oftalmologia
Legale)
Organizz.: Consiglio Direttivo SIOL - Società Italiana di Oftalmologia LegaleSegr. Organizz.: UNIKA CONFERENCES&EVENTS SrlTel. +39 0544 [email protected]
14 OTTOBRE 2017
Roma, Eataly4° Nutraceutica e occhio
Direttore Scientifico.: G.L. ScuderiSegr. Organizz.: JAKA CONGRESSI Srl Tel. +39 06 [email protected]
14 OTTOBRE 2017
Bologna, Royal Hotel CarltonXVIII Congresso nazionale
SICOP
Organizz.: S. Cavazza, G.L. LaffiSegr. Organizz.: I&C SrlTel. +39 051 [email protected]
20-21 OTTOBRE 2017
MilanoVideocatarattarefrattiva 2017
Segr. Scient.: L. BurattoSegr. Organizz.: Medicongress SrlTel. +39 02 [email protected]
26-27 OTTOBRE 2017
Roma, Ergife Palace8° Congresso Nazionale A.I.M.O.
Organizz.: Associazione Italiana Medici Oculisti Segr. Organizz.: JAKA CONGRESSI Srl Tel. +39 06 [email protected]
22-23 SETTEMBRE 2017
Camposanpiero (PD)What’s new 2017
Organizz.: G. Beltrame - M. ChizzoliniSegr. Organizz.: UNIKA CONFERENCES&EVENTS SrlTel. +39 0544 [email protected]/eventi/what-new-2017
29-30 SETTEMBRE 2017
Milano1° CONGRESSO NAZIONALE
G.O.A.L.
L’oculista territoriale: il
presente e il futuro
Segr. Organizz.: Across Events SrlTel. +39 0382 576634 [email protected] www.acrossevents.com
6 OTTOBRE 2017
Roma La patologia vascolare
dell'occhio
Presidenti: Gianluca Scuderi, Leopoldo SpadeaSegr. Organizz.: JAKA CONGRESSI Srl Tel. +39 06 [email protected]
6-7 OTTOBRE 2017
Pavia, Università di Pavia Aula del ‘40032° Congresso Nazionale
SIOP “Società Italiana di
Oftalmologia Pediatrica”
Segr. Organizz.:Formazione ed Eventi SrlTel. +39 06 [email protected]
128
Cationorm® - La prima nanoemulsione cationica per il trattamento dei sintomi dell’occhio secco
Ripristina lo strato lipidico riducendo l’evaporazione1,2
Stabilizza efficacemente il film lacrimale1,2
Agisce su tutti e 3 gli strati del film lacrimale1,2
Migliora significativamente segni e sintomi1,2
CON I VANTAGGI DELLA TECNOLOGIA NOVASORB
1. Lallemand F et al. J Drug Deliv 2012: 604204 2. Amrane M et al. J Fr Ophthalmol 2014 Aug 12; doi: 10.1016/j.jfo.2014.05.001.
Senza conservanti, compatibile con le lenti a contatto