QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab...

71
ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test Report VITA-350P (Product Reliability Test) Report No : 08S068A0 Report Date : September 18, 2008 _______________________ _____________________ ___________________ Issue Stamp Charles Chang Manager of QA Department Charles Chang Approval Knight Hu Test Engineer

Transcript of QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab...

Page 1: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified

ADVANTECH CO., LTD.

QA Test Report

VITA-350P

(Product Reliability Test)

Report No : 08S068A0

Report Date : September 18, 2008 _______________________ _____________________ ___________________

Issue Stamp

Charles Chang Manager of QA Department

Charles Chang Approval

Knight Hu Test Engineer

Page 2: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

1

VITA-350P Table of Contents Report No.08S068A0

QA Lab Reliability test

1. Test item list …………………………………………………… 2 2. Product specification entry …………………………………… 3 3. Product configuration photo………………………………….. 4 4. High temperature operation test ……………………………… 11 5. Low temperature operation test ………………………………. 14 6. Power ON/OFF test ………………………………………….... 17 7. Cold start test……….………………………………………….. 20 8. Humidity test………………………………………………….. 24 9. High temperature/humidity storage test……………………… 27

10. Low temperature storage test…..…………………………….. 30 11. Thermal profile test……………………………………………. 33 12. Random vibration test…………………………………………. 37 13. Package vibration test…………………………………………. 43 14. Package drop test……………………………………………... 51 15. Shock test………………………………………………………. 63

Page 3: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

2

VITA-350P Test Item List Report No.08S068A0

QA Lab Reliability test

Num. Test item Result Remark1 High temperature operation test Passed 2 Low temperature operation test Passed 3 Power ON/OFF test Passed 4 Cold start test Passed 5 Humidity test Passed 6 High temperature/humidity storage test Passed 7 Low temperature storage test Passed 8 Thermal profile test Passed

9 Random vibration test Passed 10 Package vibration test Passed 11 Package drop test Passed 12 Shock test Passed

Page 4: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

3

VITA-350P Product Spec Entry Report No.08S068A0

QA Lab Reliability test Num Item Specification

1 CPU Xscale PXA255 200Mhz 2 Memory Winbond SDRAM W9825G6EH-6 LCD Display Toshiba I/O port COM Port x 1 (2 wire)

USB client LVDS port DI/O

HDD San disk On board flash H3 256MB Dimension ( Wx Hx D ) 121.3 x 83.01 x 30 mm (47.76" x 32.68" x 11.81") Weight 170 g (0.375 lb) Power supply VITA : input rating 12V @ 1.2A and 24V @ 0.6A

TREK: input rating 5V @ 1A and 3.3V @ 0.5A

Page 5: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

4

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo I:

VITA-350P receive module right-front side view

Page 6: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

5

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo II:

VITA-350P receive module left-rear side view

Page 7: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

6

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo III:

VITA-350P receive module structure photo I

Page 8: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

7

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo IV:

VITA-350P receive module structure photo II

Page 9: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

8

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo V:

VITA-350P panel module front side view

Page 10: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

9

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo VI:

VITA-350P panel module rear side view

Page 11: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

10

VITA-350P Product Configuration Photo Report No.08S068A0

QA Lab Reliability test Photo VII:

VITA-350P panel module structure view

Page 12: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

11

VITA-350P High Temp. Operation Test Report No.08S068A0

QA Lab Reliability test Test Date : August 7, 2008 ~ August 8, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition :

1. Test Temperature : 75℃ 2. Test Times : 24Hrs 3. Test Software: Using Dial-up connections to connect GPRS and GPS signal from

satellite and basic station in WinCE 4. Test Environment Curve :

Temp℃

75℃

25℃

time Hrs 0:0 2:00 26:00 28:00

Page 13: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

12

VITA-350P High Temp. Operation Test Report No.08S068A0

QA Lab Reliability test

Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance.

Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Page 14: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

13

VITA-350P High Temp. Operation Test Report No.08S068A0

QA Lab Reliability test Conclusion : Passed.

The VITA-350P meets high temperature operation test.

Page 15: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

14

VITA-350P Low Temp. Operation Test Report No.08S068A0

QA Lab Reliability test Test Date : August 8, 2008 ~ August 9, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition :

1. Test Temperature : -20℃ 2. Test Times : 24Hrs 3. Test Software: Using Dial-up connections to connect GPRS and GPS signal

from satellite and basic station in WinCE 4. Test Environment Curve :

Temp℃

25℃

-20℃

Time Hrs

0:0 2:00 26:00 28:00

Page 16: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

15

VITA-350P Low Temp. Operation Test Report No.08S068A0

QA Lab Reliability test

Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/14/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1.All system functions must be checked with appropriate testing programs and should pass the inspection.

2.The system should not have degradation in its performance.

Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Page 17: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

16

VITA-350P Low Temp. Operation Test Report No.08S068A0

QA Lab Reliability test Conclusion : Passed.

The VITA-350P meets low temperature operation test.

Page 18: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

17

VITA-350P Humidity Test Report No. 08S068A0

QA Lab Reliability test Test Date : August 9, 2008 ~ August 11, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures Test Ca : Damp Heat steady state Test Test Condition :

1. Test Temperature : 40℃ 2. Test Humidity : 95%

3. Test Times : 48Hrs 4. Test Software: Using Dial-up connections to connect GPRS and GPS signal

from satellite and basic station in WinCE 5. Test Environment Curve :

Humidity %

Temp℃

95%

40℃

25℃

50%

Time Hrs 0:00 1:00 49:00 50:00

Page 19: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

18

VITA-350P Humidity Test Report No. 08S068A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance.

Mechanical function check: 1. The switch button and cover slot should work properly without any

interference. 2. All screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Page 20: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

19

VITA-350P Humidity Test Report No. 08S068A0

QA Lab Reliability test Conclusion : Passed.

The VITA-350P meets humidity test.

Page 21: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

20

VITA-350P Power ON/OFF Test ReportNo.08S068A0

QA Lab Reliability test Test Date : August 12, 2008 ~ August 16, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test

IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition :

1. Test Temperature: -20℃ and 75 ,℃ 2. Power ON / OFF time interval: On 1min, Off 1 min. at low temperature

On 1min, Off 30 sec. at high temperature 3. Number of test: 1000 times for each temperature 4. Test OS mode: Linux 5. Power ON / OFF time interval curve

75℃ condition -20℃ condition Power ON Power OFF Power ON time Power ON time 1 minute. 1 minute.

Power OFF time Power OFF time 30 seconds. 1 minute

Page 22: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

21

VITA-350P Power ON/OFF Test ReportNo.08S068A0

QA Lab Reliability test

6. Test Environment Curve: (75℃) 1 2 998 999 1000 Times iiiiiiiiiiii 0:00 25:30

7. Test Environment Curve: (-20℃)

1 2 998 999 1000 Times iiiiiiiiiiii 0:00 34:00

Temp℃

75℃

Power ON

25℃

Power OFF

Time Hrs

Temp℃

25℃

Power ON

-5℃

Power OFF

Time Hrs

Page 23: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

22

VITA-350P Power ON/OFF Test ReportNo.08S068A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp Model : THS-D4L+-100 Date of Calibration : 03/06/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Test Data :

Test temperature Test times Test Result -20 ℃ 1000 times 1000 times pass

75 ℃ 1000 times 1000 times pass Performance Criteria : Electronic function check:

1. It could not failure any time during 1000 times testing. 2. All system functions must be checked with appropriate testing programs

and should pass the inspection. 3. The system should not have degradation in its performance.

Mechanical function check:

1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found.

Page 24: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

23

VITA-350P Power ON/OFF Test ReportNo.08S068A0

QA Lab Reliability test Test Result :

There is no failure time during 1000 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The VITA-350P meets power on/off test.

Page 25: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

24

VITA-350P Cold Start Test ReportNo.08S068A0

QA Lab Reliability test Test Date : August 17, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition :

1. Test Temperature: -20℃ 2. Storage times: 4Hrs 3. Power ON / OFF time interval: On 1 minutes, Off 10 minutes 4. Number of test: 20 times 5. System loading: Windows XP

6. Power ON / OFF time interval curve Power ON Power OFF 4hours 1 mins. 10mins. Power Off time Power ON time

Power OFF time Repeat 20 cycles

VITA-350P Cold Start Test ReportNo.08S068A0

Page 26: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

25

QA Lab Reliability test

7. Test Environment Curve: 1 2 18 19 20 Times iiii 0:0 1:45 5:45 9:45 11:30

Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-D4L+- 150-LN2 Date of Calibration : 05/05/2008 Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Temp℃

25℃

Power ON

-20℃

Power OFF

Time Hrs

Page 27: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

26

VITA-350P Cold Start Test ReportNo.08S068A0

QA Lab Reliability test Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance. 3. It could not failure any time during 20 times testing.

Test Result :

There is no failure time during 20 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The VITA-350P meets cold start test.

Page 28: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

27

VITA-350P High temp./humi. Storage test Report No.08S068A0

QA Lab Reliability test Test Date : August 18, 2008 ~ August 19,2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures

Test Ca : Damp heat steady state test Test Condition :

1. Test Temperature : 60℃ 2. Test Humidity : 95% 3. Test Times : 24Hrs 4. Test Environment Curve :

Humidity %

Temp℃

95%

60℃

25℃

50%

Time Hrs 0:00 1:00 25:00 26:00

Page 29: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

28

VITA-350P High temp./humi. Storage test Report No.08S068A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber

K.SON. CO. LTD. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008

Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance.

Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Page 30: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

29

VITA-350P High temp./humi. Storage test Report No.08S068A0

QA Lab Reliability test Conclusion :

Passed. The VITA-350P meets high temperature and humidity storage test.

Page 31: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

30

VITA-350P Low Temp. Storage Test Report No.08S068A0

QA Lab Reliability test Test Date : August 19, 2008 ~ August 20, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -40℃ 2. Test Times : 24Hrs 3. Test Environment Curve :

Temp℃

25℃

-40℃

Time Hrs

0:0 1:30 25:30 27:00

Page 32: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

31

VITA-350P Low Temp. Storage Test Report No.08S068A0

QA Lab Reliability test Test Equipment : Programmable Temperature & Humidity Chamber

K.SON. CO. LTD. Model : THS-D4L+-150-LN2 Date of Calibration : 05/05/2008

Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance.

Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found.

Page 33: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

32

VITA-350P Low Temp. Storage Test Report No.08S068A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The VITA-350P meets low temperature storage test.

Page 34: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

33

VITA-350P Thermal Profile Test Report No. 08S068A0

QA Lab Reliability test Test Date : August 23, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference Advantech QA_Lab thermal profile testing procedures Test Condition : 1. Test Temperature : 31.4℃ 2. Test Times : Each temperature 6 Hrs 3. Test EUT under box with no air flow ambient

4. Test Software: Using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE

Test Equipment : DATA LOGGER YOKOGAWA CO. LTD. Model : uP-1800 S/N : 47XS0063 Date of Calibration : 9/12/2007

VITA-350P Thermal Profile Test Report No. 08S068A0

Page 35: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

34

QA Lab Reliability test Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance. Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found.

Page 36: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

35

VITA-350P Thermal Profile Test Report No. 08S068A0

QA Lab Reliability test Test Data :

NUM Parts List Measurement

31.4℃

Calculation

70℃

SEPC.

1. Ublox LEA-5S-0-002 45.6 84.2 85 (Tc)

2. Infineon PMB 7850E 47.4 86.0 90 (Tc)

3. W9825G6EH-6 47.3 85.9 90 (Tc)

4. Intel PXA255A0C 200 46.5 84.8 85 (Tc)

5. DS90C385A 49.2 85.1 70 (Ta)

6. DS90C3854 (Panel) 39.8 78.4 85 (Ta)

Remark :

Ta : Ambient temperature specification Tc : Device Case temperature specification Advantech define : Tc = Ta +20C Test Result :

1. The system specification of thermal profile is 70 degree C. 2. There is no damage in electronic functions or degradation has not been

found. 3. Performance is maintained with no incurable physical damage or

degradation. Conclusion : Passed

The VITA-350P meets thermal profile test.

Page 37: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

36

VITA-350P Thermal Profile Test Report No. 08S068A0

QA Lab Reliability test Photo:

VITA-350P test photo

Page 38: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

37

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test Test Date : September 8, 2008 Test Site : Integrated Service Technology Inc. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference MIL-STD-810F 514.5C-3 Testing procedures Test Condition :

1. Test Acceleration: X axis 1.62Grms, Y axis 2.05grms, Z axis 2.2Grms 2. Test Frequency : 5-500Hz 3. Test Axis : X, Y, Z axis 4. Test Time : 1hr per axis

5. Test Software: Using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE

6. Test Vibration Curve :

Page 39: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

38

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test

Page 40: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

39

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test Test Equipment : Vibration Simulator System

SHINKEN G-0230N Shake system. S / N: SG-4345 Date of Calibration: 03/19/2008

Vibration Simulator System

SHINKEN G-0250L Shake system. S / N: SG-4795 Date of Calibration: 06/06/2008

Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance.

Mechanical function check: 1. The switch button ,covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smooth, and no deformed parts found.

Page 41: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

40

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion :

Passed. The VITA-350P meets random vibration operation test.

PHOTO I:

VITA-350P Random vibration test Z axis

Page 42: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

41

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test PHOTO II:

VITA-350P Random vibration test Y axis

Page 43: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

42

VITA-350P Random vibration operation test Report No.08S068A0

QA Lab Reliability test PHOTO III:

VITA-350P Random vibration test X axis

Page 44: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

43

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test Test Date : September 27, 2007; September 8, 2008 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-64 Testing procedures Test Fh : Vibration broadband random test Test Condition : 1. Test PSD : 0.026G²/Hz (2.16Grms) 2. Test Frequency : 5-500Hz 3. Test Axis : X,Y and Z axis 4. Test Time : 30 minutes per axis 5. Test Curve :

Acceleration 2.16Grms -6db/oct

PSD 0.026g²/Hz

5Hz 100Hz 500Hz

Page 45: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

44

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test

Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-800F2K-40N120 S / N: MC107142493 Date of Calibration: 07/09/2008

Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

2. The system should not have degradation in its performance. Mechanical function check:

1. The switch button covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be

smoothes, and no deformed parts found.

Page 46: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

45

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The VITA-350P System meets package vibration test. PHOTO I:

VITA-350P package vibration test Z axis

Page 47: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

46

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test PHOTO II:

VITA-350P package vibration test X axis

Page 48: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

47

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test PHOTO III:

VITA-350P package vibration test Y axis

Page 49: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

48

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test PHOTO IV:

VITA-350P(panel) package vibration test X axis

Page 50: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

49

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test PHOTO V:

VITA-350P(panel) package vibration test Y axis

Page 51: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

50

VITA-350P Package Vibration Test Report No.08S068A0

QA Lab Reliability test PHOTO VI:

VITA-350P(panel) package vibration test Z axis

Page 52: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

51

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test Test Date : August 19, 2007; September 10, 2008 Test Site : Advantech QA Environment Lab Performed By: Knight Hu Purpose : The DVT test Test Standard : Reference Federal Standard 101 Method 5007 Testing procedure B

Test Ea : Drop Test Test Condition (Receive module):

1. Test Phase : One corner Three edges Six faces

2. Test High : 100cm 3. Package Weight : 600 g 4. Package Dimension : 25.5cm× 18.0cm× 6.0cm 5. Test Drawing :

Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner

Page 53: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

52

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test Test Condition (Panel module):

1. Test Phase: One corner Three edges

Six faces 2. Test High : 100cm 3. Package Weight : 1.1K g 4. Package Dimension : 32.0cm× 23.5cm× 10.5cm 5. Test Drawing :

Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner Test Equipment : Drop Tester Machine YOSHIDA SEIKI Co. LTD. Model : DT-100B

Page 54: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

53

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate programs and should pass the inspection.

Mechanical function check:

1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the board enclosure must be smooth,

and no deformed parts should be found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion :

Passed. The VITA-350P meets package drop test.

Page 55: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

54

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO I:

VITA-350P structure photo

Page 56: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

55

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test

PHOTO II:

VITA-350P corner test photo

Page 57: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

56

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test

PHOTO III:

VITA-350P edge test photo

Page 58: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

57

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO IV:

VITA-350P face test photo

Page 59: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

58

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO V:

VITA-350P(panel) corner test photo

Page 60: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

59

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO VI:

VITA-350P(panel) edge test photo

Page 61: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

60

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO VII:

VITA-350P(panel) face test photo

Page 62: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

61

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO VIII:

VITA-350P(panel) structure photo

Page 63: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

62

VITA-350P Package drop Test Report No.08S068A0

QA Lab Reliability test PHOTO IX:

VITA-350P(panel) structure photo

Page 64: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

63

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test Test Date : August 8, 2008 Test Site : Integrated Service Technology Lab. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-27 testing procedures

Test Ea : Shock test Test Condition :

1. Test condition: Operation, using Dial-up connections to connect GPRS and GPS signal from satellite and basic station in WinCE

2. Test pulse shape : half sine wave 3. Test acceleration 50G, pulse duration 11 ms 4. Test method : six faces (front, rear, left, right, top & bottom side)

three times per side 5. Test Curve :

Half Sine Wave

11ms Pulse Duration time

Shock Acceleration 50G

Page 65: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

64

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test Test Equipment : LAB AUTO-SHOCK II 2432 Shock tester

Serial Number : 181028 Date of Calibration: 03/19/2008

Sample Configuration & Quantity Under Test : Using one VITA-350P Rev.A1 with the following options installed :

1. Main board: VITA-350P REV.A1 2. Wireless LAN: SIEMENS 133851-V02 3. LCD: Display TREK-305 REV.A1 4. Adapter: LE-0309BDSP12V

Performance Criteria : Electronic function check:

1. All system functions must be checked with appropriate testing programs and should pass the inspection.

Mechanical function check:

1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately.

3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth ,and no deformed parts should be found. Test Result :

There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation.

Conclusion : Passed.

The VITA-350P meets shock test.

Page 66: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

65

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO I:

VITA-350P shock test for bottom side

Page 67: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

66

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO II:

VITA-350P shock test for top side

Page 68: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

67

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO III:

VITA-350P shock test for right side

Page 69: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

68

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO IV:

VITA-350P shock test for left side

Page 70: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

69

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO V:

VITA-350P shock test for rear side

Page 71: QA Test Report - Advantech · 2008. 9. 18. · 2 VITA-350P Test Item List Report No.08S068A0 QA Lab Reliability test Num. Test item Result Remark 1 High temperature operation test

70

VITA-350P Shock Test ReportNo.08S068A0

QA Lab Reliability test PHOTO VI:

VITA-350P shock test for front side