PUE Zabrze radial axial eng - Deutsche Messe...

16
CFXH CFH CFM CFMT CFL Centrifugal Low Pressure Fans Centrifugal Medium Pressure Fans Centrifugal Extrem High Pressure Fans Centrifugal High Pressure Fans Centrifugal Conveying Fans PRODUCT REVIEW STEEL INDUSTRIAL FANS MAFG MAFR HAFC MAF Axial Medium Pressure Fans Axial High Pressure Fans Axial Garage Fans Axial Roof Fans MAFW Axial Wall Fans

Transcript of PUE Zabrze radial axial eng - Deutsche Messe...

Page 1: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

CFXHCFHCFM

CFMT

CFL

Centrifugal Low Pressure Fans

Centrifugal Medium Pressure Fans

CentrifugalExtrem High Pressure Fans

Centrifugal High PressureFans

Centrifugal Conveying Fans

PRODUCT REVIEW

STEELINDUSTRIALFANS

MAFGMAFRHAFCMAF

Axial Medium Pressure Fans

AxialHigh Pressure Fans

AxialGarage Fans

AxialRoof Fans

MAFW

AxialWall Fans

Page 2: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

TECHNICAL INFORMATION

2

Conversion table

Units of measurement

from unit of measurement

with conversion factor

in units of measurement

from units of measurement

with conversion factor

into units of measurement

Pressure bar 1000 mbar mbar 0,001 bar

Pressure mbar 100 Pa Pa 0,01 mbar

Pressure mmWS 0,098 mbar mbar 10,2 mm H2O

Pressure mWS 98,07 mbar mbar 0,0102 m H2O

European units of measurement in the USA

from SI-unit of measurement

with conversion factor

into anglo-amer. unit of measur.

from anglo-amer. unit of measur.

with conversion factor

from SI-units of measurement

Pressure bar 0,014 psi = Ib/in² psi = Ib/in² 68,95 mbar

Pressure mbar 14,5 psi = Ib/in² psi = Ib/in² 0,068 bar

Pressure mmWS 0,402 inches water inches water 2,49 mbar

Volumetric fl ow rate m³/min 264,2 gal/min gal/min 0,003 m³/min

Volumetric fl ow rate m³/min 35,31 cfm cfm 0,028 m³/min

ElectricalPower output

kW 1,341 hp hp 0,746 kW

Length mmWS 0,039 inches water inches water 25,4 mm

Length m 39,37 inches water inches water 0,025 m

Length mmWS 0,003 ft ft 305 mm

Length m 3,28 ft ft 0,305 m

Weight kg 2,05 Ib Ib 0,454 kg

Example for conversion

Pressure 180 mbar 0,014 2,61 PSI 2,61 PSI 68,95 180 mbar

Volumetric fl ow rate 6 m³/min 35,31 211,8 ft³/min 211,8 ft³/min 0,283 6 m³/min

Page 3: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

CFLCENTRIFUGAL LOW PRESSURE FANS

up to 87.000 m³/h and 3.100 Pa

Page 4

CFHCENTRIFUGAL HIGH PRESSURE FANS

up to 115.000 m³/h and 9.000 Pa

Page 6

CFMTCENTRIFUGAL CONVEYING FANS

up to 29.500 m³/h and 6.100 Pa

Page 8

CFMCENTRIFUGAL MEDIUM PRESSURE FANS

up to 99.000 m³/h and 5.400 Pa

Page 5

CFXHCENTRIFUGAL EXTREM HIGH PRESSURE FANS

up to 104.000 m³/h and 13.900 Pa

Page 7

OVERVIEW CENTRIFUGAL FANS

3

Page 4: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

CFL rangeRectangular casing welded from mild steel, impellers unilaterally sucking with welded, backward-bent circulararch vanes from steel. Low-maintenance squirrel cagemotors to IP 55. The fans can be supplied inclockwise or anti-clockwise rotation. Direct driven with conventional motor B3 or fl ange motor B5, belt driven with base frame . Variable execution, 2-step speed variable, stepless by frequency converter. A variety of accessories like connectors , inspection door , drainage plug etc.Special designs for specifi c applications, e. g. for highermedia fl ow and ambient temperatures, with improvedcorrosion protection, with sealed housing parts, for special voltage and frequency.

Applications• Conveying of high air volumes at low and medium system resistance• Extracting fumes and vapours• Cooling apparatus and machinery parts• Ventilation of rooms• Forced air supply for gas, oil and coal fi red systems• Drying parts of various size and composition• Supplementary cooling of electric machines

CFL

CENTRIFUGAL LOW PRESSURE FANS

43.500

3.000

2.500

2.000

1.500

1.000

500

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 10.000 20.000 30.000 40.000 50.000 60.000 70.000 80.000 90.000 100.000Volumetric flow rate V (m³/h)

.

Page 5: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

CENTRIFUGAL MEDIUM PRESSURE FANS

CFM

CFM rangeRectangular casing welded from mild steel, impellers unilaterally sucking with welded, backward-bent circular arch vanes from steel. Low-maintenance squirrel cagemotors to IP 55. The fans can be supplied in clockwise or anti-clockwise rotation. Direct driven with conventional motor B3 or fl ange motor B5, belt driven with base frame. Variable execution, 2-step speed variable, stepless by fre-quency converter. A variety of accessories like, connectors, inspection door, drainage plug etc.Special fans for specifi c applications, e.g. for higher media fl ow and ambient temperatures, with improved corrosion protection, with sealed housing parts, for special voltage and frequency.

Applications• Conveying of high air volumes at higher system resistance• Ventilation of installations with higher system resistance• Air supply for drying installations• Ventilation of rooms/buildings• Air supply for fi lters and dust extraction

56.000

5.000

4.000

3.000

2.000

1.000

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000Volumetric flow rate V (m³/h)

.

Page 6: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

CENTRIFUGAL HIGH PRESSURE FANS

CFH rangeRectangular casing welded from mild steel, impellers unilaterally sucking with welded, backward-bent circular arch vanes from steel. Low-maintenance squirrel cage mo-tors to IP 55. The fans can be supplied in clockwiseor anti-clockwise rotation. Direct driven with contentional motor B3 or fl ange motor B5, belt driven with base frame. Variable execution, 2-step speed variable, stepless by fre-quency converter. A variety of accessories like, connectors, inspection door, drainage plug etc.Special fans for specifi c applications, e. g. for higher media fl ow and ambient temperatures, with improved corrosion protection, with sealed housing parts, for special voltage and frequency.

Applications• Conveying of high volumes at higher system resistance• Vacuum operation• Forced air supply for gas, oil and coal fi red systems• Air supply for drying installations

CFH

610.000

9.000

8.000

7.000

6.000

5.000

4.000

3.000

2.000

1.000

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000Volumetric flow rate V (m³/h)

.

Page 7: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

CFXH

CENTRIFUGAL EXTREM HIGH PRESSURE FANS

CFXH rangeRectangular casing welded from mild steel, impellers uni-laterally sucking with welded, backward-bent circulararch vanes from steel. Low-maintenance squirrel cage motors to IP 55. The fans can be supplied in clockwiseor anti-clockwise rotation. Direct driven with contentionalmotor B3 or fl ange motor B5, belt driven with base frame.Variable execution, 2-step speed variable, stepless byfrequency converter. A variety of accessories as connec-tors, inspection door , drainage plug etc.Special fans for specifi c applications, e. g. higher media fl ow and ambient temperatures, with improved corrosionprotection, with sealed housing parts, for special voltage and frequency.

7

Applications• Conveying of high air volumes at very high system resistance• Air tube conveying• Cooling of Power station• Ventilation of rooms/buildings

16.000

14.000

12.000

10.000

8.000

6.000

4.000

2.000

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000Volumetric flow rate V (m³/h)

.

Page 8: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

8

CFMT

CENTRIFUGAL CONVEYING FANS

Application• Conveying of plastic granules, plastic waste and lightweight bulk materials of all kind provided there is no operational risk.

CFMT rangeRectangular casing welded from mild steel, impellersunilaterally sucking with welded, backward-bent circulararch vanes from steel. Low-maintenance squirrel cagemotors to IP 55. The fans can be supplied in clockwise or anti-clockwise rotation. Direct driven with contentio-nal motor B3 or fl ange motor B5, belt driven with base frame.Variable execution, 2-step speed variable, stepless byfrequency converter. A variety of accessoires as connec-tors, inspection door, drainage plug etc.Special fans for specifi c applications, e. g. higher mediafl ow and ambient temperatures, with improved corrosionprotection, with sealed housing parts, for special voltage and frequency.

7.000

6.000

5.000

4.000

3.000

2.000

1.000

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 5.000 10.000 15.000 20.000 25.000 30.000 35.000Volumetric flow rate V (m³/h)

.

Page 9: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

MAFAXIAL MEDIUM PRESSURE FANS

up to 168.500 m³/h and 1.350 Pa

Page 10

MAFRAXIAL ROOF FANS

up to 67.000 m³/h and 1.100 Pa

Page 12

MAFWAXIAL WALL FANS

up to 52.000 m³/h and 860 Pa

Page 14

HAFCAXIAL HIGH PRESSURE FANS

up to 145.000 m³/h and 5.200 Pa

Page 11

MAFGAXIAL GARAGE FANS

up to 168.500 m³/h and 2.600 Pa

Page 13

9

OVERVIEW AXIAL FANS

Page 10: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

MAF

AXIAL MEDIUM PRESSURE FANS

MAF rangeCasing of sheet-steel hot dip galvanized or painted with welded fl anges. Impellers made from aluminium or plastic.Low-maintenance squirrel cage motors to IP 55. The fans can be supplied in clockwise, anti-clockwise rotation or reversible.Direct driven with conventional foot motor B3. Variable execution, 2-step speed variable, stepless by frequency converter. A variety of accessories like connectors, feet, dampers etc.Special designs for specifi c applications, e. g. for highermedia fl ow and ambient temperatures, with improvedcorrosion protection, with sealed housing parts, for spe-cial voltage and frequency.

10

Applications• Conveying of high air volumes at low and medium system resistance• Extracting fumes and vapours• Cooling apparatus and machinery parts• Ventilation of rooms• Forced air supply for gas, oil and coal fi red systems• Drying parts of various size and composition• Supplementary cooling of electric machines

1.600

1.400

1.200

1.000

800

600

400

200

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000 140.000 160.000 180.000Volumetric flow rate V (m³/h)

.

Page 11: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

11

HAFC

AXIAL HIGH PRESSURE FANS

Applications• Conveying of high air volumes at higher system resistance• Ventilation of installations with higher system resistance• Air supply for drying installations• Ventilation of rooms/buildings

HAFC rangeCasing of sheet-steel hot dip galvanized or painted with welded fl anges.Impellers made from aluminium or plastic.Low-maintenance squirrel cage motors to IP 55. The fans are contra rotating in series with two impellers and two motors. Direct driven with conventional foot motor B3. Variable execution, 2-step speed variable, stepless by frequency converter. A variety of accessories like, connec-tors, feet, dampers etc.Special fans for specifi c applications, e.g. for higher media fl ow and ambient temperatures, with improved corrosion protection, with sealed housing parts, for special voltage and frequency.

6.000

5.000

4.000

3.000

2.000

1.000

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000 140.000 160.000Volumetric flow rate V (m³/h)

.

Page 12: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

MAFR

AXIAL ROOF FANS

MAFR rangeCasing of sheet steel hot dip galvanized or painted with welded fl anges.Impellers from aluminium or plastic . The mushroom-shaped roof hood and the base plate are also made from hot dip galvanized or painted sheet steel. Low-maintenance squirrel cage motors to IP 55. Direct driven with foot motor B3. Variable execution, 2-step speed variable, stepless by frequency converter.

12

Application• Exhaustion of the air from halls/buildings

1.200

1.000

800

600

400

200

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 10.000 20.000 30.000 40.000 50.000 60.000 70.000 80.000Volumetric flow rate V (m³/h)

.

Page 13: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

13

MAFG

AXIAL GARAGE FANS

Applications• Ventilation of garages• Ventilation of rooms/buildings• Exhaustion of gases and vapors

MAFG rangeTwo fans connected in series with a fl ow straightener.Casing of sheet steel hot dip galvanized or painted with welded fl anges. Impellers made from aluminium or plastic. Low-mainte-nance squirrel cage motors to IP 55. Direct driven with contentional foot motor B3.Variable execution, 2-step speed variable, stepless by frequency converter. A variety of accessories like, connec-tors, feet, dampers etc.Special fans for specifi c applications, e. g. for higher media fl ow and ambient temperatures, with improved corrosion protection, with sealed housing parts, for spe-cial voltage and frequency.

3.000

2.500

2.000

1.500

1.000

500

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 20.000 40.000 60.000 80.000 100.000 120.000 140.000 160.000 180.000Volumetric flow rate V (m³/h)

.

Page 14: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

MAFW

AXIAL WALL FANS

MAFW rangeWall plate made from plastic with screwed in motor suspension in wire guard.Protected against accidental contact by wire guard on the motor side according to DIN EN294.Impeller from aluminium or plastic infi nitely adjustable when at rest.Low-maintenance squirrel cage motors to IP 55. Direct driven with fl ange motor B5.

14

Application• Cooling of damp register

1.000

900

800

700

600

500

400

300

200

100

0

Tota

l pre

ssur

e di

ffer

ence

Δpt

(Pa)

0 10.000 20.000 30.000 40.000 50.000 60.000Volumetric flow rate V (m³/h)

.

Page 15: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

02.0

9/02

15

FOR YOUR NOTES

Page 16: PUE Zabrze radial axial eng - Deutsche Messe AGdonar.messe.de/exhibitor/hannovermesse/2017/B77255/product-revi… · 02.09/02 MAF AXIAL MEDIUM PRESSURE FANS MAF range Casing of sheet-steel

Elektror airsystems gmbh

Hellmuth-Hirth-Str. 2

D-73760 Ostfi ldern

Tel. +49 711 31973-0

Fax +49 711 31973-5000

[email protected]

www.elektror.com

Elektror airsystems sp. z o.o.

ul. Hagera 24B

PL-41-800 Zabrze

Tel. +48 32 277 65 65

Fax +48 32 277 65 61

[email protected]

www.elektror.pl

7015

40 0

2.09

/02

PRODUCT REVIEW

STEELINDUSTRIALFANS

Centrifugal Fans

Axial Fans