T
125E
EF#1
GENERAL MECHANICAL LEGEND
SYMBOL DESCRIPTION
SUPPLY DUCTWORK
RETURN DUCTWORK
EXHAUST DUCTWORK
OUTSIDE AIR DUCTWORK
FIRE DAMPERF
COMBINATION FIRE & SMOKE DAMPERFS
SUPPLY AIR DIFFUSER
RETURN OR EXHAUST AIR REGISTER
DAMPER
UNDERCUT DOOR ƒ"
DOOR GRILLE - SEE PLANS FOR SIZE
MANUAL VOLUME DAMPER (M.V.D.)
MOTORIZED VOLUME DAMPER
S.D. SMOKE DETECTOR
8"0 NECK SUPPLY AIR DIFFUSER @ 200 C.F.M.8"0200
8"X8" RETURN AIR REGISTER @ 150 C.F.M.8X8
150R
6"X6" EXHAUST AIR REGISTER @ 100 C.F.M.6X6
100E
T SPACE THERMOSTAT MOUNTING HEIGHT PER ADA (48" AFF)
SPACE HUMIDISTATH
S WALL SWITCH FOR CONTROL; MOUNTING HEIGHT PER ADA
SUPPLY DUCT THRU SLAB OR ROOF - SEE PLANS
RETURN OR EXHAUST DUCT THRU SLAB OR ROOF - SEE PLANS
ROUND DUCTWORK OR FLUE UP THRU ROOF OR SLAB
AH/HP#1
HEAT PUMP
WALKING CO
---
2" - 30%
AH#1
1325
250
0.5
0.5
208/1/60
---
40.5/29.2
80/67
---
-/13.0
---
40.5
3.0/-
10.8
75 / 100
42/45
208/3/60
GAM5A0C42
HP#1
HEAT PUMP
95/47
208/3/60
13.5
1.3
18.0/30
4TWA3042
241
UNIT DESIGNATION
TYPE
SERVICE
MANUFACTURER
TOTAL C.F.M.
O.A. MINIMUM
ACCESSORIES
FILTERS
OTHER
FAN
EXTERNAL S.P.
H.P.
VOLTAGE
COOLING COIL
HEATING COIL
E.A.D.B./L.A.D.B.
VOLTAGE
CONDENSER FAN F.L.A.
TYPE
CONDENSING UNIT
MODEL NO.
DX SPLIT SYSTEM WITH
ELECTRIC HEAT
TOT/SENS CAP. (MBH)
VOLTAGE
COMPRESSOR R.L.A.
UNIT M.C.A./M.O.C.P.
55/83
150
TRANE
UNIT DESIGNATION
TYPE
SERVICE
C.F.M.
STATIC PRESSURE
SONES
H.P.
VOLTAGE
ACCESSORIES
DAMPER TYPE
SCREEN TYPE
MANUFACTURER
MODEL #
EXHAUST FAN SCHEDULE
S.S.S. CONTROLLER
WALL/ROOF CAP.
MOTOR WITH INTERNAL OVERLOAD
EF#1 & 2
CENTRIFUGAL
TLT & JAN
125
0.375
2
90 WATTS
120-1-60
---
BACKDRAFT
---
YES
YES
WALL
COOK
GC-144
MIN. E.E.R./S.E.E.R.
HP HEATING CAP. M.B.H.
ELECTRIC HEAT K.W.
E.A.D.B./L.A.D.B. (°F)
E.A.D.B./E.A.W.B. (°F)
L.A.D.B./L.A.W.B. (°F)
AHU & ELEC.HT. MCA/MOCP
O.A.D.B.(SUMMER/WINTER)
WEIGHT (POUNDS)
WEIGHT (POUNDS)
MODEL NO.
MIN. C.O.P./H.S.P.F.
M1
H.V.A.C.
FLOOR PLAN
H.V.A.C.
FROM STRUCTURE
AHU#1 SUSPENDED
O.A.INTAKE
225
8"Ê
550
12"Ê
550
12"Ê
DESIGN O.A. CFM = 250
MINIMUM O.A. CFM = 118.8
420 SQ.FT. X 0.12 CFM/SQ.FT. = 50.4
STORAGE: 0.12 CFM/SQ.FT.
570 SQ.FT. X 0.12 CFM/SQ.FT. = 68.4 CFM
570 SQ.FT. X 15P./1K.SQ.FT. X 7.5 CFM/P. = 64 CFM
SALES: 7.5CFM/PERSON; 0.12 CFM/SQ.FT.; 15P/1K.SQ.FT.
VENTILATION CALCULATIONS
125E
EF#2
1075R
24X24
20X12
10X10
18X14
16X14
10X14CONFIRM LOCATION
TO EXTERIOR -
10X10 E.A. ROUTE
REQUIREMENTS.
LOCATION W/SHELL BUILDING
HP#1 ON ROOF - CONFIRM
G. COORDINATE ADDITIONAL REQUIREMENTS WITH THE SHOPS AT NANUET CONSTRUCTION REQUIREMENTS.
F. REFERENCE ARCHITECTURAL ELEVATIONS FOR LOCATIONS OF LOUVERS AND WALL CAPS.
E. REFERENCE CONTROL SCHEMATICS & DUCTWORK DETAILS FOR MANUAL AND AUTOMATIC DAMPER LOCATIONS.
PROVIDE MECHANICAL ROOM SHOP DRAWINGS AS REQUIRED FOR COORDINATION.
D. MAINTAIN CLEARANCES FOR SERVICE OF HVAC EQUIPMENT AS REQUIRED BY MANUFACTURER AND NEC 110.26.
C. MAINTAIN CLEARANCES FROM ELECTRICAL PANELS AS REQUIRED BY N.E.C.
ANY AIR OUTLETS WITHIN 3 FEET OF CEILING SMOKE DETECTORS.
B. COORDINATE CEILING AIR INLETS AND OUTLETS WITH REFLECTED CEILING PLAN. DO NOT LOCATE
FOR REVIEW.
CHANGES IN DUCT ROUTING OR DUCT SIZING AS A SHOP DRAWING TO THE ARCHITECT/ENGINEER
A. COORDINATE DUCTWORK WITH ALL TRADES PRIOR TO FABRICATION. SUBMIT ANY MAJOR
GENERAL NOTES:
FINISHED ROOF
SEE ROOF DWG
INSULATION BY
CONTRACTOR
PATE OR EQUAL
BASE SECTION
COUNTER FLASHING
INSULATION, SEE ARCH. DWG.
WOOD NAILER
FLASHING TO BE RUN UP
UNDER COUNTER FLASHING
12" MINIMUM ABOVE
1†"
COORDINATE MISC. STRUCT.
STEEL SUPPORT UNDER
CURBS WITH ARCH. DWGS.
DIMENSION AS
REQUIRED-
A1
SCALE: NONE
PRE-FAB EQUIPMENT MOUNTING SUPPORT
BY EQUIPMENT PROVIDED
SIZE TO BE DETERMINED
5•" TO 11•" - ACTUAL
METAL ROOF DECKING AND
SUPPLY
DUCT
RETURN
DUCT
A/C UNIT
FULL SIZE RUN - OUTS (INCLUDING
HOSE KIT FURNISHED WITH EQUIPMENT
TO UNIT CONNECTION.
CONNECT HANGER RODS
TO STRUCTURE AS REQ'D.
REFRIGERANT PIPING
REF PLANS FOR SIZE
D.X. FAN COIL UNIT
EMERGENCY DRAIN PAN
VIBRATION ISOLATORS &
BRACKETS
B9
SCALE: NONE
NOTE: PROVIDE MINIMUM 30" CLEAR ON PIPING SIDE OF UNIT FOR SERVICE ACCESS.
AND RETURN
4" FLEX ON SUPPLY
REF. DETAIL
TRAPPED COND. DRAIN.
SHEET METAL
SCREW (TYP.)
SEAL
WEATHER
PROOF
ANCHOR w/ HEX HEAD
METAL SCREWS & LEAD
WASHERS.
TREATED WOOD
NAILER.
PLASTIC GROMMET
w/ STAINLESS STEEL
CLAMPS ON EACH
PIPE (TYP.)
ANCHOR TO METAL DECK.
PIPE CURB DETAIL
(TYPICAL)
1•" INSULATION7•" BASE FLANGE.
2"X2" PRESSURE
A10
SCALE: NONE
(TYP.)
3•" OVERHANG
AHU & ELEC HEAT SHALL HAVE SINGLE POINT POWER CONNECTION.
SCALE: 1/4" = 1'-0"
FLOOR PLAN
4:0
3:2
2
PM
7/
2/
2013
G:\
13109\
13109
m10_
001.d
gn
4:0 ':" / in.
bhunter
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
SIM
SO
N
D.LE
H
C
177680
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
P
7/2/13
L
TIM
ADJACENT TENANT
AREA SIDEWALK
(E) MALL COMMON
ADJACENT TENANT
water
dispenser
(N) HC TLT
(E) MALL CORRIDOR
ZONE
KEEP CLEAR
SALES
STOCKROOM
ADJACENT TENANT
ADJACENT TENANT
3
E D C B
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
H
2"
MIN.SLOPE AT MINIMUM
OF „" PER FOOT
AIR CONDITIONING UNIT
DRAIN PAN
NOTE:
'H' DIMENSION SHALL BE A MINIMUM OF 2" OR
EQUAL TO THE NEGATIVE FAN INLET
PRESSURE (RETURN AIR GRILLE, DUCT, FILTERS,
AND COILS).
VENT & CLEAN-OUT WITH CAP:
DO NOT SEAL CAP TO VENT.
CAP SHALL HAVE „ INCH
HOLE IN CENTER
DRAIN SHALL BE FULL SIZE
OF UNIT CONNECTION.
UNLESS OTHERWISE SPECIFIED.
CONDENSATE DRAIN FROM DRAW-THRU UNITS
A6
SCALE: NONE
12" SECTION OF
INSULATION UNDER
HANGER FOR
LIQUID LINE
•" INSULATION
•" WIDE
COPPER STRAP
HANG FROM
BUILDING STRUCTURE
DETAIL FOR REFRIGERANT LINE HANGER
A8
SCALE: NONE
DR
SUPPLY DUCT UP
SUPPLY DUCT DOWN
RETURN OR EXHAUST
DUCT DOWN
RETURN OR EXHAUST
DUCT UP
RATED WALL - SEE PLANS FOR TYPE
FIRE DAMPER - SEE PLANS FOR TYPE
FIRE DAMPER ACCESS DOOR
SQUARE ELL WITH TURNING VANES
SUPPLY AIR DIFFUSER
FLEX RUNOUT
M.V.D. OR SPIN-IN W/M.V.D.
BELL MOUTH FITTING W/
OPPOSED BLADE MANUAL
BALANCING DAMPER - TYPICAL
EACH BRANCH TAKE OFF
OR RUNOUT.
45 DEGREE TEE
TRANSITION
EXHAUST
RISE OR DROP
FULL RADIUS ELL OR SQUARE
ELL WITH TURNING VANES
FITTING - "SHOE" TYPE
REGISTER
RETURN OR
TYPICAL SUPPLY, RETURN OR EXHAUST DUCT SYSTEM
C4
SCALE: NONE
WITH EXTERNAL INSULATION
ROUND SHEET METAL RUNOUT
TURNING VANES
OR SQUARE ELL
FULL RADIUS ELL
R
W
Y1
G
C
R
W
Y1
G
AUX
120/1/60
AIR FAN
SUPPLY
AIR
RETURN
AIR
OUTSIDE
AIR
SUPPLY
MOTOR
DAMPER
C
Y2
Y2
C
C Y1
Y2
R
WITH MANUFACTURER
NOTE: VERIFY NO. OF WIRES
NO SCALE
SPLIT SYSTEM HEAT PUMP CONTROL SCHEMATIC
UNIT
OUTDOORINDOOR UNIT
AUX. HEAT
OR APPROVED EQUAL.
THERMOSTAT-HONYWELL T7350
WALL MOUNTED PROGRAMMABLE
B3
OVERRIDE
ADJUST & OCCUPANCY
REMOTE SENSOR W/SETPOINT
MECHANICAL
M2
DETAILS
PWR WIRING
208/3/60
AH/HP#1
TYPICAL FOR UNITS:
PWR WIRING
208/3/60
SIMULTANEOUSLY.
3. COMPRESSOR & ELEC HEAT MAY OPERATE
2. UNOCCUPIED MODE: FAN CYCLES & O.A. CLOSED
1. OCCUPIED MODE: FAN ON & O.A. OPEN
SEQUENCE OF OPERATION:
O.A. DAMPER CONTACT
E.F. CONTACT
RELAY:
VENTILATION
SECTION 15050 - BASIC MATERIALS AND METHODS
PART 1 GENERAL
1.1 REGULATORY REQUIREMENTS
1.2 TRANSPORTATION AND HANDLING
A. Transport and handle Products in accordance with manufacturer's instructions.
B. Promptly inspect shipments to ensure that Products comply with requirements, quantities are correct, and Products are undamaged.
C. Provide equipment and personnel to handle Products by methods to prevent soiling, disfigurement, or damage.
1.3 STORAGE AND PROTECTION
A. Store and protect Products in accordance with manufacturers' instructions, with seals and labels intact and legible.
B. Store sensitive Products in weather tight, climate controlled enclosures.
C. For exterior storage of fabricated Products, place on sloped supports, above ground.
D. Provide bonded off-site storage and protection when site does not permit on- site storage or protection.
PART 2 PRODUCTS
2.1 MECHANICAL IDENTIFICATION
A. Plastic Nameplates and Tags: Laminated three-layer plastic.
PART 3 EXECUTION
3.1 INSTALLATION
A. Install plastic nameplates with adhesive.
B. Install plastic tags with corrosion resistant metal chain.
3.2 TESTING, ADJUSTING, AND BALANCING
A. Report Forms: AABC National Standards for Total System Balance forms.
B. Air Handling Systems: Adjust to within plus or minus 5 percent for supply systems and plus or minus 10 percent for return and exhaust systems of design.
C. Air Outlets and Inlets: Adjust to within plus or minus 10 percent of design.
SECTION 15250 - MECHANICAL INSULATION
PART 1 GENERAL
NOT USED
PART 2 PRODUCTS
A. Flexible Glass Fiber: Flexible, noncombustible blanket with vapor barrier jacket.
PART 3 EXECUTION
3.1 INSTALLATION
3.2 SCHEDULES
Inch 1. Flexible Glass Fiber
of Exterior Openings Exhaust Ducts Within 10 ft 1-1/2" FSK
Supply Ducts 1-1/2" FSK Return Ducts 1-1/2" FSK
1. Provide cold ductwork with vapor barrier jacket. Seal vapor barrier
penetrations with vapor barrier adhesive.
SECTION 15650 - DIRECT EXPANSION REFRIGERATION SYSTEMS
PART 1 GENERAL
1.1 SUBMITTALS
A. Product Data: Required.
B. Shop Drawings: Not required.
C. Project Record Documents: Required.
PART 2 PRODUCTS
2.1 PIPING AND REFRIGERANT SPECIALTIES
A. Copper Tubing: Type ACR hard drawn or annealed, silver brazed.
D. Refrigerant Specialties
1. Moisture and Liquid Indicators.
2. Packed Ball Valves.
4. Straight Through Type Check Valves.
5. Permanent Straight Through Type Filter Driers.
6. Expansion Valves
7. Flexible Connectors.
compression, rotary screw compressor with control panel.
1. Capacity Reduction: Variable slide valve.
A. Units: Self-contained, packaged, factory assembled and prewired units for
outdoor use consisting of cabinet, compressors, condensing coil and fans,
PART 3 EXECUTION
3.1 INSTALLATION
A. Install units on with rubber in shear isolators.
B. Pressure test system with dry nitrogen. Perform final tests using electronic leak
detector. Test to no leakage.
3.2 APPLICATION
A. Provide line size liquid indicators in main liquid line leaving condenser.
B. Provide line size strainer upstream of each automatic valve. Where multiple
expansion valves with integral strainers are used install single main liquid line
strainer.
C. Provide shut-off valve on each side of strainer.
D. Provide permanent filter-driers.
E. Provide filter-driers in liquid line adjacent to receivers and for each solenoid
valve.
F. Provide refrigerant charging (packed angle) valve connections in liquid line
between receiver shut-off valve and expansion valve.
G. Utilize flexible connectors at or near compressors where piping configuration
does not absorb vibration.
SECTION 15850 - AIR HANDLING
PART 1 GENERAL
1.1 SUBMITTALS
A. Product Data: Required.
B. Shop Drawings: Not required.
PART 2 PRODUCTS
2.1 AIR HANDLING UNITS
A. Configuration: Fabricate with fan and coil section plus accessories.
1. Heating coil.
B. Casing: Galvanized steel on channel base, welded and coated with zinc
chromate paint, with lights with wire guards.
C. Insulation: One inch thick, neoprene coated, glass fibre.
D. Liner: Mill galvanized perforated steel.
E. Drain Pans: Galvanized steel with welded corners, cross broken and pitched to
drain connection.
F. Fan Section
1. Fan: Forward curved, centrifugal.
2. Base: Welded steel with motor slide rails, mounted on open spring
vibration isolators.
3. Mounting: Locate motor, drive, and belt guard on integral casing
framework on exterior of casing.
G. Coil Section: Enclose coils with headers and return bends within casing.
H. Filters
1. Flat arrangement with 2 inch disposable panel filters.
PART 3 EXECUTION
3.1 INSTALLATION
B. Install fans with resilient mountings and flexible electrical leads. Install flexible
connections between fan inlet and discharge ductwork.
2.2 EXHAUST FANS
A. Centrifugal Fan Unit: Direct driven with spun aluminum housing,
resilient mounted motor, gravity backdraft
damper Bird screen, and disconnect switch.
A. Install packaged air handling units on spring vibration isolators.(Hangers)
2.4 OUTDOOR UNITS
B. Solid State Speed Controller
SECTION 15880 - AIR DISTRIBUTION
PART 1 GENERAL
NOT USED
PART 2 PRODUCTS
2.1 DUCTWORK
A. Materials 1. Steel Ducts: Galvanized steel sheet, lock-forming quality. 2. Flexible Ducts: Fabric supported by helically wound spring steel wire or flat steel bands.
B. Metal Ductwork 1. Fabricate and support in accordance with SMACNA HVAC Duct Construction Standards - Metal and Flexible. 2. Construct T's, bends, and elbows with radius of 1-1/2 times width of duct on center line or provide turning vanes. 3. Increase duct sizes gradually, not exceeding 30 degrees divergence and 45 degrees convergence.
2.2 DUCT ACCESSORIES
A. Volume Control Dampers 1. Fabrication: SMACNA HVAC Duct Construction Standards - Metal and Flexible. 2. Splitter Dampers: Same gage as duct to 24 inches size and two gages heavier for larger sizes. 3. Single Blade Dampers: Fabricate for duct sizes to 12 x 30 inch. 4. End Bearings: Provide except in round ductwork 12 inches and smaller. 5. Quadrants: Provide locking, indicating regulators on dampers. Where width exceeds 30 inches provide regulator at both ends.
B. Backdraft Dampers: Fabricate multi-blade, parallel action gravity balanced backdraft dampers of galvanized steel or extruded aluminum, with center pivoted blades linked together.
C. Flexible Duct Connections: UL listed fire-retardant neoprene coated woven glass fiber fabric to NFPA 90A, approximately 3 inches wide, crimped into metal edging strip.
D. Duct Access Doors 1. Fabricate in accordance with SMACNA HVAC Duct Construction Standards - Metal and Flexible. 2. Access doors smaller than 12 inches square may be secured with sash locks. Access doors with sheet metal screw fasteners are not acceptable.
A. Ceiling Diffusers: MetalAire 5600-6. Rectangular, stamped or spun, multi-core type diffuser to discharge air in 360 degree pattern, with
B. Registers/Grilles: MetalAire CC5D. Fixed grilles of 1/2 x 1/2 x 1/2 inch louvers; with factory off-white finish.
PART 3 EXECUTION
3.1 INSTALLATION
A. Provide backdraft dampers on discharge of exhaust fans.
B. Connect diffusers to low pressure ducts with 5 feet maximum length of flexible duct.
C. Provide flexible connections immediately adjacent to equipment in ducts associated with fans and motorized equipment.
D. Provide duct access doors for inspection and cleaning before and after filters, coils, fans, automatic dampers,at fire dampers, and elsewhere as indicated.
E. Check location of air outlets and inlets and make necessary adjustments in
arrangement.
F. Provide balancing dampers on duct take-off to all diffusers, and grilles and registers.
G. Paint ductwork visible behind air outlets and inlets matte black.
baked enamel off-white finish. sectorizing baffles where indicated; radial opposed blade damper;
2.3 AIR OUTLETS & INLETS
D. T.A.B. Contractor shall be AABC or NEBB certified.
finish painting.
2. Interior exposed ductwork, rigid duct board, finish with canvas jacket sized for
3. Exterior ductwork, rigid duct board, finish with aluminum jacket.
Exterior Supply & Return Ducts 2" FSK
C. Refrigerant: R-410a.
B. Copper Tubing to ‡ inch OD: Type K, annealed, flared joints.
3. Straight Line or Angle Line Type Strainers.
2.3 SEMI-HERMETIC COMPRESSORS
A. Rotary Compressors: Direct drive, semi-hermetic 3600 RPM, fixed
coil guard & reversing valve.
integral sub-cooling coil, controls, liquid receiver, low ambient controls,
flanges of air distribution systems shall be sealed and mechanically fastened.
listed and labeled in accordance with UL181A or UL181B. Duct connections to
H. Seal all ductwork longitudinal and transverse seams and connections with sealant
position to conform with architectural features, symmetry, and lighting
A. Conform to New York Building Code, Mechancial Code and Plumbing Code.
2.1 DUCTWORK INSULATION
A. External Ductwork Insulation
A. Ductwork Insulation Thickness Finish
4:0
3:2
6
PM
7/
2/
2013
G:\
13109\
13109
m50_
001.d
gn
4:0 ':" / in.
bhunter
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
SIM
SO
N
D.LE
H
C
177680
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
P
7/2/13
L
TIM
DESCRIPTIONP-#
FIXTURE CONNECTION SCHEDULE
VENT (IN.)WASTE (IN.)H.W. (IN.)C.W. (IN.)
P-1 WATER CLOST (FLUSH TANK, H.C.) • --- 4 2
P-2 LAVATORY (WALL HUNG, SINGLE LEVER FAUCET) • • 1• 1•
P-3 SERVICE SINK (FLOOR MTD. 2X2) • • 3 1•
VOLTAGEDESIGNATION K.W.ELEMENTS
NO. OF
RISE
TEMP.
G.P.H.
RECOVERY
CAP.(GAL.)
STORAGE
DIA.
TANK
HEIGHT
TANKMANUFACTURER MODEL NUMBER
ELECTRIC WATER HEATER SCHEDULE
WH#1 1.6 120 1 90 8 6 15" 15.25 STATE INDUSTRIES ES6 6 SOMS
1. PROVIDE WILKINS MODEL 1070XL THERMOSTATIC MIXING VALVE AT EACH HANDWASH SINK OR LAVATORY. SET AT 110°F.
PLUMBING FIXTURE NOTES:
HOT WATER TO SYSTEM
GALVANIZED NIPPLE (TYPICAL)
COLD WATER TO HEATER
DIELECTRIC UNION (TYPICAL)
PIPE FULL SIZE TO DRAIN PAN
DRAIN PAN
SHELF MOUNTED IN CEILING SPACE
1" TRAPPED PIPE FROM DRAIN
DRAIN VALVE, PIPE CONNECTION
SIZE TO DRAIN PAN.
A.S.M.E. TEMPERATURE & PRESSURE
RELIEF VALVE
CHECK VALVE (TYP)
MTD IN HORIZONTAL POSITION
THERMOMETER
BUILDING WALL
H2
SCALE: NONE
ELECTRIC WATER HEATER DETAIL-SHELF MOUNTED
WATER HEATER No. 1
DIP TUBE CONNECTION
ƒ" VACUUM RELIEF VALVE OR
PAN TO XXX
BALL VALVE (TYP.)
PROVIDE MOUNTING
HEATER MANUFACTURER'S
RECOMMENDATIONS
BRACKET SIZED PER
WATER
HEATER
FINISHED FLOOR
6'- 0" MAXIMUM
ASTM EXPANSION TANK
WH#1 ON SHELF
P-2
P-1
P-3
UNDERGROUND
PLUMBING
P1
PLUMBING
UNDERGROUNDFLOOR PLAN
LOCATION.
EXISTING - CONFIRM
4"SS - CONNECT TO
TO EXISTING - CONFIRM
1" CW - CONNECT
1"
1/2"4"FCO
B. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 13 & NEW YORK BUILDING CODE.
A. TENANT SPACE HAS EXISTING FIRE SPRINKLER SYSTEM - ADJUST AS REQUIRED FOR PROPOSED WORK.
FIRE SPRINKLER NOTES:
4"VTRVV
2"
PREVENTER WITH LOCAL CODES AND ADVISE.
B. CONFIRM EXISTING BACKFLOW PREVENTER & REQUIREMENT FOR TENANT BACKFLOW
A. ALL PLUMBING WORK SHALL BE IN ACCORDANCE WITH NEW YORK PLUMBING CODE.
PLUMBING NOTES:
SCALE: 1/4" = 1'-0"
FLOOR PLAN
4:0
3:2
7
PM
7/
2/
2013
G:\
13109\
13109p10_
001.d
gn
4:0 ':" / in.
bhunter
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
SIM
SO
N
D.LE
H
C
177680
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
P
7/2/13
L
TIM
ADJACENT TENANT
AREA SIDEWALK
(E) MALL COMMON
ADJACENT TENANT
water
dispenser
(N) HC TLT
(E) MALL CORRIDOR
(E)
MA
LL C
OR
RID
OR
ZONE
KEEP CLEAR
SALES
STOCKROOM
ADJACENT TENANT
ADJACENT TENANT
3
E D C B
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
PLUMBING LEGEND
ABBREVIATIONSDESCRIPTIONSYMBOL
COLD WATER (UNDERGROUND)
COLD WATER C.W.
HOT WATER (TEMPERATURE, IF MORE THAN ONE) H.W.
HOT WATER RETURN H.W.R.
CLEAN-OUT C.O.C.O.C.O.
SANITARY SEWER (UNDERGROUND)SS
SANITARY SEWER S.S.SS
VENT VV
VENT THROUGH THE ROOF V.T.R.V.T.R.
FIRE WATER FF
AUTOMATIC SPRINKLER A/SA/S
CONDENSATE DRAIN C.D.CD
RISER IDENTIFICATION
FIXTURE IDENTIFICATION (SEE SPECIFICATIONS)P-1
VALVES (SEE SPECIFICATIONS FOR TYPE)
SHOCK STOP
BALANCING VALVEP2
PLUMBING
SECTION 15050 - BASIC MATERIALS AND METHODS
PART 1 GENERAL
1.1 REGULATORY REQUIREMENTS
1.2 TRANSPORTATION AND HANDLING
A. Transport and handle Products in accordance with manufacturer's instructions.
B. Promptly inspect shipments to ensure that Products comply with requirements, quantities are correct, and Products are undamaged.
C. Provide equipment and personnel to handle Products by methods to prevent soiling, disfigurement, or damage.
1.3 STORAGE AND PROTECTION
A. Store and protect Products in accordance with manufacturers' instructions, with seals and labels intact and legible.
B. Store sensitive Products in weather tight, climate controlled enclosures.
C. For exterior storage of fabricated Products, place on sloped supports, above ground.
D. Provide bonded off-site storage and protection when site does not permit on- site storage or protection.
PART 2 PRODUCTS
2.1 MECHANICAL IDENTIFICATION
A. Plastic Nameplates and Tags: Laminated three-layer plastic.
PART 3 EXECUTION
3.1 INSTALLATION
A. Install plastic nameplates with adhesive.
B. Install plastic tags with corrosion resistant metal chain.
SECTION 15250 - MECHANICAL INSULATION
PART 1 GENERAL
NOT USED
PART 2 PRODUCTS
2.1 PIPE INSULATION
A. Glass Fiber: Rigid molded, noncombustible with vapor barrier jacket.
B. Cellular Foam: Flexible, cellular elastomeric, molded or sheet.
C. Jackets 1. PVC Plastic: One piece molded type fitting covers.
PART 3 EXECUTION
3.1 INSTALLATION
A. Piping Insulation 1. Provide cold pipes with vapor barrier jackets. Insulate complete system. 2. Provide hot pipes with standard jackets. Bevel and seal ends of insulation at equipment, flanges, and unions.
3.2 SCHEDULES
A. Piping Insulation Pipe Size Thickness Inch Inch 1. Glass Fiber or Cellular Foam Insulation
PART 1 GENERAL
1.1 SYSTEM DESCRIPTION
A. Design Requirements Sprinkler System: light hazard occupancy requirements.
B. System to provide coverage for entire building.
C. Determine volume and pressure of incoming water supply from water flow test.
Base design on test.
1.2 SUBMITTALS
A. Product Data: Required.
B. Shop Drawings: Required.
C. Samples: Not required.
D. Project Record Documents: Required.
E. Submit shop drawings, product data and hydraulic calculations to authority
having jurisdiction for approval prior to submittal to Architect/Engineer.
1.3 QUALITY ASSURANCE
A. Regulatory Requirements
1. Sprinkler Systems: Conform to NFPA 13.
PART 2 PRODUCTS
2.1 PIPE AND TUBE
A. Steel: Schedule 10 or 40 black, with steel, cast iron, or malleable iron fittings,
or mechanical grooved couplings.
2.2 SPRINKLERS
A. Suspended Ceiling Type: Quick Response semi-recessed pendant type with
chrome plated finish, and matching escutcheon. Manufacturers: Viking,
Grinnel, Star or Central.
B. Exposed Area Type: Standard upright type with brass finish.
2.3 FIRE DEPARTMENT CONNECTION
2.4 BACKFLOW PREVENTER
SECTION 15400 - PLUMBING
PART 1 GENERAL
NOT USED
PART 2 PRODUCTS
2.1 PIPING
2.2 VALVES
(screwed) 2" & smaller T585-70 BA-300 8300
2.3 SPECIALTIES
A. Cleanouts: Lacquered cast iron, two piece body with round scoriated cover in service areas and square cover, depressed to accept floor finish in finished floor areas. Manufacturers: J.R. Smith, Josam, Wade.
2.5 WET PIPE SPRINKLER ALARM VALVE
2.6 WATER MOTOR ALARM
2.7 WATER FLOW SWITCH
PART 3 EXECUTION
3.1 INSTALLATION
A. Install in accordance with NFPA 13.
B. Provide gate valves for shut-off or isolating service. Where approved, use
butterfly valves instead of gate valves.
C. Provide drain valves at main shut-off valves, low points of piping and
apparatus.
D. Connect system to water source ahead of domestic water connection with
double check valve assembly.
F. Hydrostatically test entire system. Test shall be witnessed by Fire Marshal or
authority having jurisdiction.
END OF OUTLINE
service main where water is used exclusively for fire protection purposes.
E. Sprinkler contractor shall install all fire protection service from tap of the
screen.
working pressure, Y pattern with•inch stainless steel perforated
2. Size 2 inch and Under: Screwed brass or iron body for 175 psig
2. Wilkins
1. Muller
B. Other acceptable manufactures offering equivalent products.
A. Watts
1. Manufactures:
E. STRAINERS
pressure actuated, capacities ASME certified and labelled.
2. Bronze body, teflon seat, steel stem and springs, automatic, direct
2. Wilkins
1. Mueller.
B. Other acceptable manufactures offerings equivalent products.
A. Watts
1. Manufactures:
D. RELIEF VALVES
single union ends.
internal parts, fabric reinforced diaphragm, strainer, threaded and
2. Up to 2 inches: Bronze body, stainless steel and thermoplastic
2. Wilkins.
1. Mueller
B. Other acceptable manufactures offering equivalent products.
A. Watts
1. Manufactures:
C. WATER PRESSURE REDUCING VALVES
considered.
B. Other manufactures offering equivalent products will be
A. DeZurik Permaseal.
1. Manufactures:
B. PLUG VALVES
(solder) 1" & smaller S-585-70 A-150 8311
Manufacturers: Watts Model 909, Febco, Wilkens, or Hersey.
assembled with two gate valves, strainer, and four test cocks.
1. Reduced Pressure Backflow Preventers: ASSE 1013; bronze body;
C. Backflow Preventers
B. Water Hammer Arrestors: To PDI WH-201, precharged.
2.4 PLUMBING FIXTURES
A. Water Closet - Handicapped (P-1) 1. Bowl
b) Other acceptable manufacturers offering equivalent products. 1. American Standard
3. Crane
2. Seat a) Manufacturer: Church Model 9500C. b) Other acceptable manufacturers offering equivalent products. 1. Beneke 2. Olsonite c) Solid white plastic, open front, less cover.
3. Trim a) Manufacturer: McGuire Model 172LK 1/2" x 3/8" sweat supply with loose key stop.
B. Lavatory (P-2) 1. Basin
b) Other acceptable manufacturers offering equivalent products. 1. American Standard
3. Crane c) ASME A112.19.2; wall hung lavatory, vitreous china, 20 x 18 inch minimum, with 4 inch high back, drillings on 4 inch centers, rectangular basin with splash lip, front overflow, and soap depression.
2. Faucet
b) Other acceptable manufacturers offering equivalent products. 1. Eljer 2. American Standard 3. Chicago Faucets c) 4 inch centerset, single lever faucet.
3. Trim a) Manufacturer: McGuire 1. Model 155-A lavatory grid strainer and 1-1/4 inch tailpiece. 2. Model 170LK 1/2" x 3/8" sweat lavatory supply with loose key stop. 3. Model 8872 1-1/4inch P-trap with escutcheon.
C. Janitor Sink (P-3) 1. Bowl a) Manufacturer: Stern Williams Model SBC1402.
2. Faucet
b) Other acceptable manufacturers offering equivalent products.
A. Electric Water Heaters 1. Factory-assembled and wired, electric, vertical storage type. 2. Galvanized tank, automatic thermostat, and maximum 50 psig working pressure.
PART 3 EXECUTION
3.1 INSTALLATION
A. Provide dielectric connections wherever jointing dissimilar metals.
B. Install water hammer arrestors complete with accessible isolation valve.
C. Install each fixture with chrome plated rigid or flexible supplies withC.screwdriver stops, reducers, and escutcheons.
D. Use dielectric connections only in accessible locations.
E. Install unions downstream of valves and at equipment or apparatus connections.
F. Install ball valves for shut-off and to isolate equipment, part of systems, or vertical risers.
closet, floor mounted, vitreous china, close-coupled two-peice,
flush actuator. elongated-rim, vitreous china closet tank with polished chrome
a) Manufacturer: Symmons Model S-20
1. Zurn
2.5 EQUIPMENT 4. Exterior piping - aluminum jacket and fitting covers.
3. Interior exposed piping - canvas jacket and fitting covers.
2. Cellular Foam Insulation Refrigerant Suction Piping (Inside) all sizes 1"
Floor Drains above grade all sizes •"
SECTION 15300 FIRE PROTECTION
Domestic Cold Water all sizes •"
Domestic Hot Water all sizes 1"
Refrigerant Suction Piping (Outside) all sizes 1"
D. Natural Gas: Steel, Schedule 40 Black, Threaded or Welded
C. Water Above Grade: Copper tube, Type L, hard drawn
B. Water Buried Under Building: Copper tube, Type K, annealed.
P.V.C. schedule 40
A. Sanitary Sewer Buried and Above Grade: Cast Iron Pipe, service weight or
NIBCO MILWAUKEE HAMMOND A. BALL VALVES:
A. Conform to New York Building Code, Mechancial Code and Plumbing Code.
2. Equipment and Components: UL or FM labeled.
A. Existing.
A. Existing.
A. Existing.
A. Existing.
A. Existing.
c) ANSI/ASME A112.19.3; floor mounted molded stone floor mounted sink.
a) Manufacturer: Williams T-10-VB.
c) Service sink fitting with vacuum breaker & 3/4" hose thread with bucket hook.
a) Manufacturer: Kohler Model K-3427.
c) ANSI/ASME A112.19.2; 16ƒ" high flush tank water
a) Manufacturer: Kohler Model K-2032.
2. Elkay
2. Elkay
LEGEND &SPECIFICATIONS
12:1
2:0
8
PM
7/
3/
2013
G:\
13109\
13109p60_
001.d
gn
4:0 ':" / in.
bjoin
s
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
SIM
SO
N
D.LE
H
C
177680
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
P
7/2/13
L
TIM
FLOOR PLAN
E1LIGHTING
LIGHTING
SWITCH BANK DETAIL
1
A B
SHEET NOTES
TRACK
PERIMETER
SALES AREA
WINDOW
SALES
LIGHTS
SALES AREA
C
2
EXISTING LIGHTING CIRCUITS THROUGH NEW CONTACTOR.
INSTALL NEW LIGHTING CONTACTOR ABOVE EXISTING PANELS. WIRE
D E
ROOM
STORE
E3E3E3E3
E3
E3
E3E3 E3 E3
E3
E3 E3 E3
E3E3E3E3E3
LIGHTING FIXTURE (LUMINAIRE) SCHEDULE
MARK
J
EM
X1
X2
MANUFACTURER
TEXAS FLUORESCENTS
EXITRONIX
EXITRONIX
EXITRONIX
NOTES:
1. THE NIGHT LIGHT FIXTURES MARKED "NL" SHALL NOT BE SWITCHED.
2. THE BATTERY PACK FIXTURES SHALL BE CONNECTED TO THE UNSWITCHED SIDE OF THE LOCAL LIGHTING CIRCUIT.
3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT FIXTURE LOCATIONS.
4. VERIFY ALL FIXTURE COLORS WITH ARCHITECT PRIOR TO ORDER.
CATALOG NUMBER
IND-132-W30MV
LED-90
VEX-U-BP-WB-WH
V902-U-WB-RC-WH
N0. LAMPS/TYPE
1/32W T8
FURNISHED
FURNISHED
FURNISHED
WATTS
28
8
3
5
VOLTS
120/277
120/277
120/277
120/277
MOUNTING
SURFACE
UNIVERSAL
UNIVERSAL
CEILING
REMARKS
COMMERCIAL STRIPLIGHT, PROVIDE W/ WIREGUARD
TWO LAMP EMERGENCY LIGHTING UNIT
LED EXIT SIGN W/ BATTERY PACK
EDGELIT EXIT SIGN W/ BATTERY PACK
WW
DL
JUNO LIGHTING 25R56-42E-SATSF-825 2/42W TRT 93 120 RECESSED 2 LAMP, LENSED, WALL WASH
JUNO LIGHTING 23R56-42E-SATSF-825 2/42W TRT 93 120 RECESSED 2 LAMP, LENSED, DOWNLIGHT
E3 CON-TECH LIGHTING RAN27L-X-X-12-N-X3-X-HBC-24 3/27W LED 81 120 RECESSED MULTI-SPOT RECESSED DOWNLIGHT. OUTSIDE HEADS TO BE MEDIUM DIST, INSIDE HEAD TO BE FLOOD
E4 CON-TECH LIGHTING RAN27L-S-X-12-N-X4-X-HBC-24 4/27W LED 108 120 RECESSED MULTI-SPOT RECESSED DOWNLIGHT. ALL HEADS TO BE SPOT DISTRIBUTION.
ER EXITRONIX RDG-6-12-WH FURNISHED 4 120/277 RECESSED RECESSED ADJUSTABLE EMERGENCY DOWNLIGHT WITH BATTERY PACK
SS
SWITCH BANKX1
X1
EM
X2
ERERER
WW
WW
DL DL DL
J JJ
J
J
J
J
JJ
J
J
J
J
J
E4
E4
DL
E3
DL
DL
DL
THRU C
A-7
A-1TO SaTO Sb
NL
NL
TO ScA-3
e
e
e
d
d
d
d
d
e
e
d
e
PANEL A
2
1
1
SO
A-5
EM
ROOM
STORE
UNSWITCHED LIGHT AND FIXTURE
NL
NL
SCALE: 1/4" = 1'-0"
FLOOR PLAN
12:1
2:0
5
PM
7/
3/
2013
G:\
13109\
13109
E1
L_
001.D
GN
4:0 ':" / in.
bjoin
s
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
BILIN
GS
B.L
UA
P
409-1
270
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
L
7/2/13
ADJACENT TENANT
AREA SIDEWALK
(E) MALL COMMON
ADJACENT TENANT
water
dispenser
(N) HC TLT
(E) MALL CORRIDOR
(E)
MA
LL C
OR
RID
OR
ZONE
KEEP CLEAR
SALES
STOCKROOM
ADJACENT TENANT
ADJACENT TENANT
3
E D C B
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
E2
FLOOR PLAN
POWER/SYSTEMS
POWER/SYSTEMS
1
SHEET NOTES
WALKING COMPANY STANDARDS). SEE DETAIL ON THIS SHEET.
RECEPTACLE FOR POS/INTERNET KIOSK (LOCATE ACCORDING TO
FURNISH AND INSTALL ONE ISOLATED GROUND QUAD
3.
5.
4.
GENERAL ELECTRICAL NOTES
2.
1.
UPON AN AMPERE LOAD EQUAL TO 8O% OF THE OVERCURRENT DEVICE AMPERE RATING.
DROP SHALL NOT EXCEED THAT ALLOWED BY CODE AND SHALL BE CALCULATED BASED
ACCOMMODATE FOR VOLTAGE DROP BASED ON LENGTHS OF INSTALLED CIRCUITS. VOLTAGE
3/4". CONTRACTOR IS RESPONSIBLE FOR INCREASING CONDUCTOR AND CONDUIT SIZES TO
ELECTRICAL CODE. MINIMUM CONDUCTOR SIZE IS #12 AWG AND MINIMUM CONDUIT SIZE IS
CONDUCTORS AND CONDUIT SHALL BE SIZED IN ACCORDANCE WITH THE NATIONAL
WHERE CIRCUIT HOMERUNS DO NOT INDICATE THE CONDUCTOR OR CONDUIT SIZE, THE
PRIOR TO ORDERING FIXTURES.
TYPES ARE COMPATIBLE WITH FINAL CEILINGS INSTALLED. THIS SHALL BE COORDINATED
FIXTURES AND CEILING TYPES. CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT FIXTURE
REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR ACTUAL LAYOUT OF LIGHT
ON BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART.
UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN THIS CONNECTION
UNDER WHICH HE WILL HAVE TO OPERATE AND WHICH WILL IN ANY WAY AFFECT THE WORK
DRAWINGS AND VISIT CONSTRUCTION SITE TO BE FAMILIAR WITH EXISTING CONDITIONS
PRIOR TO SUBMITTING BID PROPOSAL, BIDDER SHALL EXAMINE ALL SPECIFICATIONS AND
A GROUNDING LUG AT THE CONDUIT TERMINATION IN THE PANEL.
CONDUIT SHALL BE BONDED AND CONNECTED TO THE GROUND BAR IN THE PANELBOARD VIA
ALL BRANCH CIRCUITS SHALL INCLUDE A GREEN GROUNDING CONDUCTOR AND THE METAL
GENERAL DEMOLITION NOTES
4.
3.
2.
C.
B.
1.
A.
SHALL BE TERMINATED AS FOLLOWS:
ALL CONDUIT AND WIRING FEEDING SAID DEVICES OR EQUIPMENT
DEVICES AND EQUIPMENT FROM EXISTING WALLS BEING DEMOLISHED.
ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL
BE ABANDONED. WIRING SHALL BE REMOVED BACK TO SOURCE.
TO MATCH EXISTING. REMAINDER OF CONDUIT BELOW SLAB SHALL
OF FINISHED SLAB WITH HOLE IN SLAB PATCHED AS REQUIRED
CONDUITS FEEDING FROM SLAB SHALL BE CUT-OFF BELOW TOP
MATCH EXISTING.
CEILINGS SHALL BE REPLACED OR REPAIRED AS REQUIRED TO
DISCONNECTED AND REMOVED BACK TO SOURCE. DAMAGE TO
CONDUITS FEEDING FROM ABOVE DROPPED CEILING SHALL BE
WIRE SHALL BE PULLED THE ENTIRETY OF NEW CIRCUITS.
EQUIPMENT HAS BEEN REMOVED FROM MIDPOINT OF CIRCUIT. NEW
EXISTING FEED-THROUGH CIRCUITRY WHERE EXISTING DEVICE OR
ELECTRICAL CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF ALL
OR REPAIRED AS REQUIRED TO MATCH EXISTING.
OR DAMAGED UNDER THIS SUB-CONTRACT SHALL BE REPLACED
ALL EXISTING WALLS, CEILINGS, FLOOR SLABS, ETC., BEING CUT
PROPERLY DISPOSED OF BY THE ELECTRICAL CONTRACTOR.
OWNER'S REPRESENTATIVE AND IF NOT ACCEPTED BY HIM SHALL BE
ETC., BEING REMOVED AND NOT RELOCATED SHALL BE FIRST OFFERED TO
ALL EXISTING LIGHTING FIXTURES, WIRING DEVICES, CONTROL EQUIPMENT,
ALL EXISTING CIRCUITRY TO REMAIN DURING CONSTRUCTION.
THE ELECTRICAL CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF
6.
SHALL BE LEVITON MIDWAY BROWN.
"ASIAN SUN" FINISHALL RECEPTACLES AND COVER PLATES MOUNTED ON THE WALL WITH
" CONDUIT, U.O.N.21ALL NEW CIRCUITS SHALL BE 2#12 & 1#12 GND IN
SCALE: NONE
H N G
H
N
WIRE NUT
METAL CONDUIT
GROUNDING
CONDUCTOR
(GREEN)
TAPPED HOLE
IN BOX
SLOTTED HEXAGON
NOTE:
METAL
GROUNDING SCREW-
#10- 32"x …"
HEAD, WASHER FACE
SCREW (TYPICAL)
GROUNDING CONDUCTOR
SHALL BE CONTINUOUS SO
THAT REMOVAL OF DEVICE
WILL NOT INTERFERE WITH
CONDUCTOR CONTINUITY.
IG
ISOLATED GROUND RECEPTACLE INSTALLATION
ISOLATED GROUND
F7
J
SIGN
+60",IG
+18",IG+18"
1
2 ABOVE WINDOW IN CEILING.
2
2
+60",IG
+18",IG+18"
KIOSK
POS/INTERNET1
PANEL A
DISCONNECT
60 AMP
ELECTRICAL ROOM
EQUIPMENT IN MALL
METER AND SERVICE
60 AMP FEEDER TOTRANSFORMER
30 KVA
RISER DIAGRAMSCALE: NONE
+48"
4'X8' TTB
NEW PANEL A
ABOVE
TRANSFORMER
30 KVA
DISCONNECT
60 AMP
KIOSK
POS/INTERNET
FUTURE
A-17
A-15 A-19
TIMECLOCK
A-21 THRU
A-11
A-13
A-9
A-23
EF-1
EF-2
A-8/10/12
60A/3F/WP
60A/3F
A-2/4/6
30A/1F
A-25
WH-1
SCALE: 1/4" = 1'-0"
FLOOR PLAN
4:0
3:3
0
PM
7/
2/
2013
G:\
13109\
13109
E1
P_
001.D
GN
4:0 ':" / in.
bhunter
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
BILIN
GS
B.L
UA
P
409-1
270
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
L
7/2/13
ADJACENT TENANT
AREA SIDEWALK
(E) MALL COMMON
ADJACENT TENANT
water
dispenser
(N) HC TLT
(E) MALL CORRIDOR
(E)
MA
LL C
OR
RID
OR
ZONE
KEEP CLEAR
SALES
STOCKROOM
ADJACENT TENANT
ADJACENT TENANT
3
E D C B
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
24" x 3
6"
GENERAL NOTES AND SPECIFICATIONS
A. GUARANTEE ALL MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM
DATE OF ACCEPTANCE.
B. COMPLY WITH THE NEC, STATE, AND LOCAL CODES.
C. USE ONLY COPPER CONDUCTORS. MINIMUM SIZE #12 AWG. USE TYPE
THHN, UON. ALL CIRCUITS SHALL BE COLOR CODED.
D. USE MINIMUM•" CONDUIT. USEƒ" MINIMUM GALVANIZED COATED
WITH ASPHALTUM OR SCHEDULE 40 PVC IN CONCRETE BELOW GRADE.
FOR PVC, TRANSITION TO RIGID BEFORE EMERGING FROM BELOW. USE
EMT WHERE CONCEALED IN WALLS AND CEILINGS. USE RIGID IN SLAB
AND UNDERGROUND.
E. USE STAINLESS STEEL DEVICE COVER PLATES, UON.
F. SUBMIT 6 COPIES OF SHOP DRAWINGS.
G. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED, COMMERCIAL
GRADE.
H. USE HUBBELL WIRING DEVICES AS FOLLOWS:
SWITCHES - 15 AMP, #1201-I, 1202-I, 1203-I
SWITCHES - 20 AMP, #1221-I, 1222-I, 1223-I, 1224-I
SWITCHES - 20 AMP, DECORA WHITE (LEVITON)
SWITCHES - MOTOR STARTERS, USE SQUARE D CLASS 2510
RECEPTACLES - 15 AMP, #5252-I, 5262-I FOR GENERAL
PURPOSES.
RECEPTACLES - 20 AMP, SG63H-I FOR SAFETY TYPE.
RECEPTACLES - GFCI, GF5262-I (I5A), GF5362-I (20A).
I. ALL WIRING MUST BE IN CONDUIT.
J. EQUIPMENT OUTSIDE MUST BE WEATHERPROOF. USE HEAVY DUTY
DISCONNECT SWITCHES.
K. CONDUIT OUTSIDE MUST BE GALVANIZED STEEL OR PVC, AS NOTED
ABOVE.
L. USE 6' MAXIMUM LENGTH OF FLEXIBLE CONDUIT TO FIXTURES.
M. FLUORESCENT FIXTURES SHALL HAVE HOLD DOWN CLIPS.
N. REMOVE TEMPORARY WIRING UPON COMPLETION OF WORK. REMOVE
UNUSED EXISTING WIRING UPON COMPLETION OF WORK.
O. USE BUSS TYPE LPS OR LPN FUSES FOR MOTORS AND EQUIPMENT.
USE BUSS TYPE KTS OR KTN FUSES FOR PANEL AND TRANSFORMER
FEEDERS.
P. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL UTILITIES, MECHANICAL
EQUIPMENT AND EQUIPMENT FURNISHED BY OWNER PRIOR TO ROUGH-IN.
Q. INCANDESCENT FIXTURES SHALL HAVE 150 DEGREES C WIRING FROM
OUTLET BOX TO LAMPHOLDERS.
R. FLUORESCENT LAMPS SHALL BE ENERGY SAVING TYPE T8, 3500
DEGREES KELVIN, UON. PHILLIPS, GENERAL ELECTRIC, OR SYLVANIA.
S. FLUORESCENT FIXTURES SHALL BE FURNISHED WITH ENERGY SAVING
ELECTRONIC BALLASTS.
T. INCANDESCENT LAMPS SHALL BE 130 VOLT, INSIDE FROSTED, UON.
U. METAL HALIDE LAMPS SHALL BE GENERAL ELECTRIC OR SYLVANIA.
V. USE "PATE" PIPE SEALS FOR CONDUIT THROUGH ROOF. USE SEALTITE
FLEXIBLE CONDUIT FOR EXTERIOR EQUIPMENT. USE «" SEALTITE
FLEXIBLE CONDUIT FOR VIBRATING EQUIPMENT.
W. PANELBOARDS SHALL BE GENERAL ELECTRIC OR SQUARE D, UON.
X. TELEPHONE TERMINAL BOARD SHALL BEƒ"X4'X 8' A-D PLYWOOD
PAINTED WITH TWO COLORS OF FLAT GRAY ENAMEL. PROVIDE #6 GND.
TO MAIN GROUNDING ELECTRODE.
Y. VERIFY LOCATION OF PANELBOARDS AND SWITCHES WITH ARCHITECT
PRIOR TO ROUGH-IN.
Z. CONTRACTOR SHALL COORDINATE NEW SERVICE REQUIREMENTS WITH
THE LOCAL POWER COMPANY AND FURNISH THEM LOAD INFORMATION.
FURNISH SERVICE TO TRANSFORMER POLE AS REQUIRED BY THE
POWER COMPANY.
AA. DO NOT INSTALL MORE CONDUCTORS IN A BRANCH CIRCUIT HOMERUN
THAN SHOWN.
BB. ALL WORK SHALL BE COORDINATED WITH OWNER'S REPRESENTATIVE.
CC. INSTALL CONTROL WIRING IN MINIMUM•" CONDUIT FOR ALL FAN
TERMINAL UNITS TO THERMOSTATS AND ROOFTOP UNITS, ETC. SEE
MECHANICAL CONTROL AND MANUFACTURER'S DRAWINGS.
DD. USE SEALTITE FLEXIBLE CONDUIT FOR EXTERIOR EQUIPMENT.
EE. NEW BREAKERS REQUIRED SHALL MATCH AIC RATINGS OF EXISTING
BREAKERS IN PANELS SHOWN.
FF. AIR COOLED DRY TYPE TRANSFORMER SHALL BE SQUARE D OR
GENERAL ELECTRIC. TRANSFORMER IS TO MEET NEMA ST20 WITH
RATINGS AS INDICATED. EQUIP FOR MOUNTING AS INDICATED.
GG. LIGHTING CONTACTORS ARE TO BE 20A NEMA ICS2, MECHANICALLY
HELD WITH COIL VOLTAGE AS INDICATED. POLES AS INDICATED, PLUS 2
SPARE. ENCLOSURE TO BE ANSI/NEMA ICS 6, TYPE 1. SQUARE D,
GENERAL ELECTRIC, AND ASCO ARE ACCEPTABLE.
HH. TIME CLOCKS ARE TO BE 40A, NEMA ICS, 7 DAY TIMER WITH
ASTRONOMICAL DIAL AND 12 HOUR SPRING CARRY OVER. PROVIDE
WITH 3 POLES IN ANSI/NEMA ICS 6, TYPE 1 ENCLOSURE. ACCEPTABLE
ARE TORK (7200ZL/7302ZL), PARAGON OR INTERMATIC EQUALS.
II. PHOTOELECTRIC CONTROL SHALL BE FIXED MOUNTED, SPST, WITH 2
MINUTE DELAY AND 2000 WATT CONTACT RATING. INSTALL IN A DIE
CAST, WEATHERPROOF ENCLOSURE.
JJ. RECEPTACLES IN WET LOCATIONS SHALL BE INSTALLED WITH AN
OUTLET ENCLOSURE CLEARLY MARKED "SUITABLE FOR WET
LOCATIONS WHILE IN USE". THERE MUST BE A GASKET BETWEEN THE
ENCLOSURE AND THE MOUNTING SURFACE, AND BETWEEN THE COVER
AND BASE TO ASSURE A PROPER SEAL. THE ENCLOSURE MUST
EMPLOY STAINLESS STEEL MOUNTING HARDWARE AND BE
CONSTRUCTED OF IMPACT RESISTANT POLYCARBONATE. THE OUTLET
ENCLOSURE SHALL BE LISTED BY UNDERWRITERS LABORATORIES INC.
ENCLOSURE MUST BE MANUFACTURED BY TAYMAC CORPORATION OR
EQUAL.
KK. FLUORESCENT LAMP EMERGENCY POWER SUPPLY SHALL BE ONE LAMP
AS SCHEDULED ON THE PLANS PROVIDING 1100-1400 LUMENS, MINIMUM.
THE BATTERY SHALL BE A NICKEL CADMIUM TYPE, RATED FOR A TEN
YEAR LIFE. INCLUDE TEST SWITCH AND AC ON INDICATOR LIGHT,
INSTALLED TO BE OPERABLE AND VISIBLE FROM THE OUTSIDE OF AN
ASSEMBLED LUMINAIRE.
NL NIGHT LIGHT (ON 24 HOURS)
EM EMERGENCY POWER, PROVIDE RED DEVICE WHEN ADJACENT TO WIRING DEVICE
ISOLATED GROUND, PROVIDE ORANGE DEVICE WHEN ADJACENT TO WIRING DEVICEIG
WEATHERPROOF (NEMA 3R)
UNLESS OTHERWISE NOTED
HEIGHT
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
EXHAUST FAN
CONDUIT
AIR HANDLING UNIT
ABOVE FINISHED FLOOR
ABBREVIATIONS
WP
UON
EX
HT
EF
C
AHU
AFF
16"
16" UON
FLOOR
FLUSH IN
WIRING DEVICES
120 VOLT DUPLEX RECEPTACLE, 20 AMPS U.O.N.
120 VOLT QUADRAPLEX RECEPTACLE, 20 AMPS U.O.N.
MULTIPLE GANG BOXES WHERE NOTED
120 VOLT DUPLEX RECEPTACLE MOUNTED IN FLOOR BOX, PROVIDE
48"
48"
48"
6'-6" *
6'-6" *
6'-6" *
S
3
SM
S
MANUAL MOTOR STARTER SWITCH (WP=NEMA 3R)
THREE WAY TOGGLE SWITCH (SEE ABBREVIATIONS ABOVE)
DISTRIBUTION EQUIPMENT
SURFACE MOUNTED LIGHTING PANELBOARD
DISTRIBUTION TYPE PANELBOARD
UNLESS NOTED WP FOR NEMA 3R ENCLOSURE.
NON-FUSIBLE SAFETY SWITCH, SIZE AND TYPE AS NOTED ON PLANS
(AMP/POLES/ENCLOSURE) OR ON SCHEDULE. NEMA 1 ENCLOSURE
SINGLE POLE TOGGLE SWITCH (K=KEY SWITCH, WP=NEMA 3R)
18" UON
MISCELLANEOUS SYMBOLS
GROUND
J
1
PB
JUNCTION BOX
PUSHBUTTON
NOTE NUMBER
COMMUNICATION
WITH FIRE RESISTANT PAINT
ABOVE ACCESSIBLE CEILING SPACE.
BELL OR BUZZER TRANSFORMERBT
* 6'-6" DISTANCE IS TO TOP-MOST DISCONNECTING DEVICE OR HIGHEST
COMUNICATION OUTLET (P=MOUNTED IN PRE FAB PARTITION RACEWAY
3/4" THICK TERMINAL BOARD, SIZE AS NOTED, PAINTED BLACK
PROVIDED WITH A 3/4" EMPTY CONDUIT, WITH PULL WIRE, TO
NOTE: EACH EMPTY JUNCTION BOX (FLOOR OR WALL MOUNTED) SHALL BE
POSITION OF OPERATING HANDLE OF DISCONNECTING DEVICE
PROVIDED WITH BATTERY PACK OR CONNECTED TO EMERGENCY POWER
WITH CHEVRON DIRECTIONAL ARROWS WHERE INDICATED ON PLANS
CEILING MOUNTED EXIT SIGN, SHADING INDICATES FACES. PROVIDE
PROVIDED WITH BATTERY PACK OR CONNECTED TO EMERGENCY POWER
WITH CHEVRON DIRECTIONAL ARROWS WHERE INDICATED ON PLANS
WALL MOUNTED EXIT SIGN, SHADING INDICATES FACES. PROVIDE
LIGHTING FIXTURES
RECESSED FLUORESCENT LIGHTING FIXTURE
RECESSED INCANDESCENT, FLUORESCENT, OR HID LIGHTING FIXTURE
WALL MOUNTED EMERGENCY BATTERY PACK LIGHTING FIXTURE
FLUORESCENT STRIP LIGHTING FIXTURE
CEILING MOUNTED EMERGENCY BATTERY PACK LIGHTING FIXTURE AS NOTED
LIGHTING TRACK WITH TRACK HEADS
ELECTRICAL LEGEND
SYMBOL DESCRIPTION
MTG HT
AFF TO
CL
MOTOR
EXISTING TO REMAIN
G
GND
A-1
A-1,3
A-1,3,5
A-1/3
A-1/3,2/4
A-1/3/5
ONE 1-POLE CKT HOMERUN TO PANEL A
TWO 1-POLE CKT HOMERUNS TO PANEL A
ONE 2-POLE CKT HOMERUN TO PANEL A
TWO 2-POLE CKT HOMERUNS TO PANEL A
ONE 3-POLE CKT HOMERUN TO PANEL A
THREE 1-POLE CKT HOMERUNS TO PANEL A
BRANCH CIRCUITING LEGEND
NOTE: ALL MULTI-WIRE BRANCH CIRCUITS TO COMPLY WITH 2008 NEC 210.4
ELECTRICAL
E3
LEGEND AND SCHEDULESFEEDER NO. CONDUIT AND WIRE
BRANCH CIRCUIT AND FEEDER LEGEND
A2 •" - 2 #12 & 1 #12 GND.
FIRE ALARM FLASHING LIGHT
FIRE ALARM FLASHING LIGHT/CHIME
B1 ƒ" - 2 #10 & 1 #10 GND.
F3 1‚" - 4 #3 & 1 #8 GND.
A3 ƒ" - 3 #12 & 1 #12 GND.
SMOKE DETECTORP
D2 1" - 3 #6 & 1 #10 GND.
B2 ƒ" - 3 #10 & 1 #10 GND.
TYPE: SERVICE:MOUNTING:
SECTIONS:
AMPS S.I.C.:
AMPS NO.SERVES
CKT.
K.W.
POLE
NO. A B
PHASE KW POLE
NO.
CKT.
K.W.SERVES
NO. AMPS
PANEL: FEEDER No.
VOLTAGE: MAINS:
C PLS.
FDR
PLS.
FDR
A NQOD SURFACE 10000 TRANS A F3
120/208V 3P,4W 100A MCB 1
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
LIGHTING SALES
LIGHTING SALES
LIGHTING STOCK
LIGHTING ENTRY
RECEPTS TTB
RECEPTS STOCKROOM
RECEPTS STOCKROOM
RECEPTS SALES
RECEPTS SALES
RECEPTS SHOW WINDOW
SIGNAGE
EF
WH-1
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
SPARE
1.54
0.86
0.40
0.60
0.36
0.36
0.36
0.54
0.54
1.20
1.20
0.40
1.60
0.50
0.50
0.00
0.00
0.00
0.00
0.00
0.00
6.58
5.90
5.44
2.76
2.52
2.52
0.36
0.54
0.54
1.20
1.20
0.40
1.60
0.50
0.50
0.00
0.00
0.00
0.00
0.00
0.00
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
---
---
---
---
--- ---
--- ---
--- ---
--- ---
--- ---
--- ---
5.04
5.04
5.04
2.16
2.16
2.16
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
AH-1
HP-1
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
SPACE ONLY
D2
B2
45
30
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
TOTALS:
TOTAL:
12.50 10.66 9.40
32.56
4:0
3:3
1
PM
7/
2/
2013
G:\
13109\
13109
E60_
001.d
gn
4:0 ':" / in.
bhunter
, LLCESIGN DRCALUB
drawings.
from the dimensions and conditions shown by these
must be notified of any variations
on the job.
be responsible to verify all dimensions and conditions
precedence over scaled dimensions. Contractors shall
project only. All dimensions in these drawings shall take
bidders and subcontractors in connection with this
Material herein is for use by authorized contractors,
26.27.13Project No.:
DGC
DateNo.
Drawn By:
Checked By:
Issued Date:
Revision
Sheet No.:
f615 228 7218
p615 227 7209
Nashville, Tennessee 37203
Suite 106a
33 Music Square West
The Shops at Nanuet
Nanuet, NY 10954
Space 9107
75 W Route 59
Sheet Title:
JSC
04.22.13
F NEWYO
RK
OETAT
S
BILIN
GS
B.L
UA
P
409-1
270
FESSIONAL
GNE
ORPD
ES
NE
CLI
N
E
ER
I
L
7/2/13