PTC31 - PTP31

7
Products Solutions Services Application / Function Overview Technical data Dimensions Electrical connection Price table Contact Go to shop Technical Datasheet TD 00039E/24/EN/01.13 Three buttons for local set-up, via ReadWin® 2000 configuration software or FieldCare High reproducibility and long-term stability Stainless steel housing 316L Complete product information: www.e-direct.us/ptc_ptp31 Specs at a glance: Product: Liquids, vapors and gases Accuracy: < 0.5 % Outputs: 1 or 2 PNP or 1 PNP with 4 to 20 mA Display: 4 digit, 14 segments, with color change Product temperature: -40 °F to +212 °F (-40 to +100 °C) Measuring range - limits: PTC31: 0 to 1.5 psi (100 mbar), 0 to 600 psi (40 bar) PTP31: 0 to 15 psi (1 bar), 0 to 6000 psi (400 bar) Pressure switch for absolute and gauge pressures Ceraphant T PTC31 / PTP31 $ 304.00

Transcript of PTC31 - PTP31

Page 1: PTC31 - PTP31

Products Solutions Services

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Technical DatasheetTD 00039E/24/EN/01.13

• Three buttons for local set-up, via ReadWin® 2000 configuration software or FieldCare

•High reproducibility and long-term stability

• Stainless steel housing 316L

Complete product information:www.e-direct.us/ptc_ptp31

Specs at a glance:

•Product: Liquids, vapors and gases

•Accuracy: < 0.5 %•Outputs:

1 or 2 PNP or 1 PNP with 4 to 20 mA

•Display: 4 digit, 14 segments, with color change

•Product temperature: -40 °F to +212 °F (-40 to +100 °C)

•Measuring range - limits: PTC31: 0 to 1.5 psi (100 mbar), 0 to 600 psi (40 bar) PTP31: 0 to 15 psi (1 bar), 0 to 6000 psi (400 bar)

Pressure switch for absolute and gauge pressures

CeraphantTPTC31 / PTP31

$ 304.00

Page 2: PTC31 - PTP31

1)

p

2)

CeraphantTPTC31 / PTP31 2

Overview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Application / Function

Application The Ceraphant T is a pressure switch designed for the monitoring and control of absolute and gauge pressures in non-hazardous applications and is available with a wide range of process connections and measuring ranges. You can choose from two kinds of measuring cell technologies:•Up to 600 psi (40 bar) choose

PTC31 with ceramic cell•Up to 6000 psi (400 bar) choose

PTP31 with metallic cell

ApplicationexampleFunction The process pressure acts on the sensor diaphragm and the pressure-dependent change in capacitance of the sensor is measured. A microprocessor evaluates the signal and provides an appropriate output.

1×PNP switch output1) Power supply system2) Load (e.g. programmable logic

controller, process contol system, relay)

Page 3: PTC31 - PTP31

CeraphantTPTC31 / PTP31 3

Application / FunctionOverview Dimensions

Electrical connection Price table ContactGo to shop

Technical data

Technicaldata

OutputOutput signal 1 or 2×PNP or 1 PNP with 4 to 20 mAFunction Min., max. windowVoltage drop PNP ≤ 2 VOverload protection Automatic testing of switching current

Power supply Ub

Supply voltage 12 to 30 V DCCurrent consumption Without load < 60 mA, reverse polarity

protection

Performance characteristicsReference conditions According to DIN IEC 60770/61003Measured error < 0.5 %Long-term drift ≤ 0.15 % per yearSensor response time ≤ 20 msAnalog output Non-linearity: ≤ 0.2 % (limit point method)

non-conformity: non-linearity + hysteresis + non-repeatability: ≤ 0.5 % (limit point method)

Operating conditionsMedium temperature -40 to +212 °F (-40 to +100 °C)Ambient temperature -40 to 185 °F (-40 to +85 °C)Storage temperature -40 to 185 °F (-40 to +85 °C)Degree of protection M16×1.5 valve plug: IP 65

M12×1 connector: IP65 (gauge press.), IP66 (absolute press.)Cable: IP 66

Vibration resistance 20 g to DIN 68-2-6 (10-2000 Hz)EMC Interference emission as per EN 61326 class

B electrical equipment, interference immunity as per EN 61326 appendix A (industrial use)

MaterialsProcess connection G ½ A to DIN 16288Housing AISI 316L, with electronically polished

surface Ra ≤ 0.8 µmValve plug Polyamide (PA)M12×1 connector Outside 316LCable outer covering Polyurethane (PUR)

Materials in contact with mediumProcess connection AISI 316LCoupling nut AISI 304Sensor diaphragm PTC31: Ceramic (99,9 % Al2O3)

PTP31: AISI 316LFilling fluid PTC31: dry ceramic measuring cell

PTP31: mineral oilSeals FKM Viton

EPDM (only PTP31)

OperationOperating elements 3 buttons or PC and software

ApprovalsDesina compliantSensors for O2-applications (only PTC31) or with 3.1. certificate on request.

Page 4: PTC31 - PTP31

CeraphantTPTC31 / PTP31 4

Application / FunctionOverview Technical data

Price table ContactGo to shopElectrical connection

Dimensions

Dimensions(ininches)

1.54

2.05

2.05

2.05

4.13

0.43

2.56

0.94

0.94

0.94

M16×1.5 connector / ½ NPT valve plugM12 ×1 connector

1.42

AF 27 mm(for 400 bar/6000 psi sensor AF 32 mm)

Ø 1.52

Ø 1.67

Cable 16.4 ft

Installation according to instruction manual.

Housing

Thread ANSI¼ FNPT

Thread ANSI½ MNPT

Thread ANSI¼ FNPT

Process connections PTC31

Process connections PTP31

Thread ANSI½ MNPT

¼ NPT

0.43

0.43

½ NPT

0.99

Ø 0.45

Ø 0.7

Ø 0.84

½ NPT

Ø 0.45

Ø 0.9

0.61

1.34 1.

850.

99

¼ NPTØ 0.45

A1

A2

A3

B

R

2

3

1

4

2

3

1

4

R1

R1

L+

L–

L+

L–R2

2

3

3

1

1

2

4

L+

L–

L+

L–

R14…20 mA

Electricalconnection

DC voltage version with M12×1 connectorA1: 1×PNP switch outputA2: 2×PNP switch outputA3: PNP switch output with additional analog output DC voltage version with valve plug M16×1.5B: 1×PNP switch output DC voltage version with cableA1: 1×PNP switch outputA2: 2×PNP switch outputA3: PNP switch output with additional analog output Cable specification: 5-core (5 × 0.22 mm²);Colors: 1 = brown, 2 = white, 3 = blue, 4 = black, ground = green/yellow

Page 5: PTC31 - PTP31

CeraphantTPTC31 / PTP31 5

Application / FunctionOverview Technical data Dimensions

Electrical connection ContactGo to shopPrice table

Pricetable(PTC31)

Ceraphant PTC31: ceramic measuring cell; up to 40 bar Order no. Price/pcs. in USDPower Supply; Output Electrical Connection 1 to 5 6 to 10 11 to 3512-30 V DC; PNP switch 3-wire

Plug M12, IP65 gauge, IP66 absolute PTC31-A1A1 3 1A 370.00 344.00 326.00Valve plug M16 ISO4400, IP65 PTC31-A2A1 3 1A 397.00 369.00 349.00Cable 5 m, IP66 PTC31-A4A1 3 1A 418.00 389.00 368.00

12-30 V DC; 2x PNP switch 4-wire

Plug M12, IP65 gauge, IP66 absolute PTC31-A1B1 3 1A 397.00 369.00 349.00Cable 5 m, IP66 PTC31-A4B1 3 1A 445.00 414.00 392.00

12-30 V DC; PNP switch + 4-20 mA 4-wire

Plug M12, IP65 gauge, IP66 absolute PTC31-A1C1 3 1A 456.00 424.00 401.00Cable 5 m, IP66 PTC31-A4C1 3 1A 504.00 469.00 444.00

Plug and cable to be ordered as ‘accessory’* Please add code for measuring range. ** Please add code for process connection.

Accessories Order no. Price/pcs. in USDM12 socket for plug. 5m cable PVC, Cu Sn/Ni lock. 52010285 13.00Configuration kit for PC-programmable devices. Set-up programme + interface cable for PC with USB-Port.

TXU10-AA 204.00

Socket for plug 4p-125V, 4A-M12 52006263 22.50M12 elbow plug ready for cable, IP67,PG7 51006327 16.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.

Complete product information:www.e-direct.us/ptc_ptp31

***

Process connections

Code ThreadDA ANSI ¼ FNPT, 316LDD ANSI ½ MNPT, 316L

**

Measuring Range

Code Gauge pressure Overload1C 0… 100 mbar, 0… 10 kPa 4 bar1F 0… 400 mbar, 0… 40 kPa 6 bar1H 0… 1 bar, 0… 100 kPa 10 bar1M 0… 4 bar, 0… 400 kPa 24 bar1P 0… 10 bar, 0… 1 000 kPa 40 bar1S 0… 40 bar, 0… 4 000 kPa 60 bar

Absolute pressure2F 0… 400 mbar, 0… 40 kPa 6 bar2H 0… 1 bar, 0… 100 kPa 10 bar2M 0… 4 bar, 0… 400 kPa 24 bar2P 0… 10 bar, 0… 1 000 kPa 40 bar2S 0… 40 bar, 0… 4 000 kPa 60 bar

*

Page 6: PTC31 - PTP31

CeraphantTPTC31 / PTP31 6

Application / FunctionOverview Technical data Dimensions

Electrical connection ContactGo to shopPrice table

Pricetable(PTP31)

Ceraphant PTP31: metallic diaphragm; Viton seal; up to 100 bar Order no. Price/pcs. in USDPower Supply; Output Electrical Connection 1 to 5 6 to 10 11 to 3512-30 V DC; PNP switch 3-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1A1 3 1A 345.00 321.00 304.00Valve plug M16 ISO4400, IP65 PTP31-A2A1 3 1A 372.00 346.00 327.00Cable 5 m, IP66 PTP31-A4A1 3 1A 393.00 365.00 346.00

12-30 V DC; 2x PNP switch 4-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1B1 3 1A 372.00 346.00 327.00Cable 5 m, IP66 PTP31-A4B1 3 1A 420.00 391.00 370.00

12-30 V DC; PNP switch + 4-20 mA 4-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1C1 3 1A 431.00 401.00 379.00Cable 5 m, IP66 PTP31-A4C1 3 1A 479.00 445.00 422.00

Ceraphant PTP31: soldered diaphragm; up to 400 bar Order no. Price/pcs. in USDPower Supply; Output Electrical Connection 1 to 5 6 to 10 11 to 3512-30 V DC; PNP switch 3-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1A1 3 7A 345.00 321.00 304.00Valve plug M16 ISO4400, IP65 PTP31-A2A1 3 7A 372.00 346.00 327.00Cable 5 m, IP66 PTP31-A4A1 3 7A 393.00 365.00 346.00

12-30 V DC; 2x PNP switch 4-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1B1 3 7A 372.00 346.00 327.00Cable 5 m, IP66 PTP31-A4B1 3 7A 420.00 391.00 370.00

12-30 V DC; PNP switch + 4-20 mA 4-wire

Plug M12, IP65 gauge, IP66 absolute PTP31-A1C1 3 7A 431.00 401.00 379.00Cable 5 m, IP66 PTP31-A4C1 3 7A 479.00 445.00 422.00

Plug and cable to be ordered as ‘accessory’* Please add code for measuring range. ** Please add code for measuring range for 400 bar sensors. *** Please add code for process connection.

Accessories Order no. Price/pcs. in USDM12 socket for plug. 5m cable PVC, Cu Sn/Ni lock. 52010285 344.00Configuration kit for PC-programmable devices. Set-up programme + interface cable for PC with USB-Port.

TXU10-AA 369.00

Socket for plug 4p-125V, 4A-M12 52006263 389.00M12 elbow plug ready for cable, IP67,PG7 51006327 369.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.

Complete product information:www.e-direct.us/ptc_ptp31

***

***

*

**

Process connections

Code ThreadDA ANSI ¼ FNPT, 316LDD ANSI ½ MNPT, 316L

***

**

MeasuringRangefor 400barsensors 1)

Code Gauge pressure Overload3Z 0...400 bar, 0...40 MPa 600 bar

Absolute pressure4Z 0...400 bar, 0...40 MPa 600 bar

1) welded, without seal

Measuring Range

Code Gauge pressure Overload3H 0… 1 bar, 0… 100 kPa 4 bar 3M 0… 4 bar, 0… 400 kPa 16 bar 3P 0… 10 bar, 0… 1 000 kPa 40 bar 3S 0… 40 bar, 0… 4 000 kPa 160 bar 3U 0… 100 bar, 0… 10 MPa 400 bar

Negative gauge pressure7H -1… +1 bar, -100… +100 kPa 4 bar 7M -1… +4 bar, -100… +400 kPa 16 bar 7P -1… +10 bar, -100… +1 000 kPa 40 bar

Absolute pressure4H 0… 1 bar, 0… 100 kPa 4 bar a 4M 0… 4 bar, 0… 400 kPa 16 bar a 4P 0… 10 bar, 0… 1 000 kPa 40 bar a 4S 0… 40 bar, 0… 4 000 kPa 160 bar a 4U 0… 100 bar, 0… 10 000 kPa 400 bar a

*

Moreproductstocompleteyourmeasuringpoint… PointlevelswitchLiquiphant T FTL20

FlowswitchFlowphant T DTT31

TemperatureswitchThermophant T TTR31

Page 7: PTC31 - PTP31

Application / FunctionOverview Technical data Dimensions

Electrical connection Price table ContactGo to shop

Contact

E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143

Direct order

Internet www.e-direct.usby phone 888- EH-DIRECT

(343-4732)per Fax 317-535-8498E-Mail [email protected]