Providing safety, reliability and performance in commercial and industrial applications xPower Plus MCCB panelboards and associated devices • MCCB panelboards

Transcript of Providing safety, reliability and performance in commercial and … Plus MCCB PB... ·...

Page 1: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

Providing safety, reliabilityand performancein commercial andindustrial applications

xPower Plus MCCB panelboards

and associated devices

• MCCB panelboards

Page 2: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

2 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Powering

electrical systems

worldwide

When it comes to making more efficient use of the world’s electrical power Eaton is at the cutting edge. Our industry-leading electrical power controlsystems help you reduce powerconsumption - and its attendantgreenhouse gas emissions.

Eaton can help you manage your complete electrical powersystem, whether it is containedwithin a manufacturingfacility, university campus,healthcare centre, data centre,geographically dispersed setof office buildings or retailstores, residential or any otherentity where electricity mustfunction with high qualityand without interruption.

The result is an unparalleledintegration of PowerChain®

solutions that optimiseenergy usage, reduceenergy consumption andenhance the comfort andsustainability of your facility.

Page 3: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

3xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

xPower Plus MCCB panelboards and associated devices 1.0

A complete range of MCCB panelboards providing

all the options you need from a straightforward

panelboard to a comprehensive panelboard system.

The range now offers a variety of incoming devices

and a greater choice of outgoing ways to provide

more flexibility and choice to the user.

xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES ..................................................................... 3

INCOMING DEVICE RATINGS UP TO 250A – OUTGOING DEVICE RATINGS UP TO 160A ..................................... 4

INCOMING DEVICE RATINGS UP TO 400A – OUTGOING DEVICE RATINGS UP TO 250A ......................................8

INCOMING DEVICE RATINGS UP TO 630A – OUTGOING DEVICE RATINGS UP TO 250A ....................................12

INCOMING DEVICE RATINGS UP TO 800A – OUTGOING DEVICE RATINGS UP TO 250A ....................................16

TECHNICAL DATA .......................................................................................................................................................20

1.01.11.21.31.41.5

Page 4: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

4 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.1 xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 250A – outgoing device ratings up to 160A

Specification

• Panelboards to IEC61439-1&2. Form 2b

• Busbar system DEKRA certified 50kA Icc, Icw 30kA/1s, 25kA/3s

• IP42 construction

• Enclosure construction made of 1.5mm sheet metal thickness

• Paint color RAL 7035 Polyester powder coating

• MCCBs to IEC60947-2. kA ratings shown are Ics=lcu at 400V ac

• Switch disconnectors to IEC60947-3

• 100% neutral busbar

• Fully type tested at operating ambient temperature of 50oC

Features

• 4, 6, 8, 10, 12, 14 or 16 outgoing TP ways

• Outgoing devices; NZM1 /LZM1 16A–125A SP & 20A–160A TP

• Tin–plated busbars

• Incomer accessible with closed door

• Can be configured for incomer device at top or bottom of panelboard

• Removable top/bottom gland plates as standard

• Wide range of extension & metering boxes available

See page 21 for dimensions.

3-pole

* For electronic trip unit please refer to MCCB catalog

NZM2

LZM2

NZMC2-A250

Poles Incoming device type

Current rating (A)

Eaton list numberShort circuit rating36kA

Articlenumber

Articlenumber

Articlenumber

Articlenumber

MCCB incoming device (Mandatory to add box terminal accessory for incoming device to connect with busbar stack) (see page 5)

• 36kA or 50kA options

• Select appropriate incomer device from table below

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, Magnetic trip adjustment 6 to 10 x In

160200250160200250

NZMC2-A160NZMC2-A200NZMC2-A250LZMC2-A160-ILZMC2-A200-ILZMC2-A250-I

NZMN2-A160NZMN2-A200NZMN2-A250LZMN2-A160-ILZMN2-A200-ILZMN2-A250-I

271421271422271423111938111939111940

187645187646187647187648187649187650187651

187539187540187541187542187543187544187545

259092259093259094174442174443174444

XPPN22508B

Incoming rating up to 250A, outgoing ratings up to 160A

NZM2/LZM2 MCCB or N2/LN2 switch disconnector

250 46810121416

XPPN22504TXPPN22506TXPPN22508TXPPN22510TXPPN22512TXPPN22514TXPPN22516T

XPPN22504BXPPN22506BXPPN22508BXPPN22510BXPPN22512BXPPN22514BXPPN22516B

• Minimum ordering requirement: panelboard + incoming device + box terminal + outgoing devices + blanking plates

• Connection kit from incoming device to main bus bar included Description Associated

incoming deviceCurrent rating(A)

No. of ways Eaton list numberTop Incomer

Eaton list numberBottom Incomer

Top Entry IncomerBottom Entry Incomer

Eaton list numberShort circuit rating50kA

Page 5: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

5xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 250A – outgoing device ratings up to 160A 1.1

3-pole (1 set per incoming device) NZM2/LZM2/N2/LN2 160250

NZM2-250-XKC

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

Box terminal for incoming device (to connect with busbar stack)

NZM2-160-XKCNZM2-250-XKC

262240262244

3-pole N2 Switch disconnectorLN2 Switch disconnector

250250

N2-250

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

Switch disconnector incoming device (Mandatory to add box terminal accessory for incoming device to connect with busbar stack) (see below)

• Select appropriate incomer device from table below

• Maximum cable capacity 185mm2

N2-250LN2-250-I

266010112004

NZMB1-1-AF63and NZMB1-A160

Outgoing devices – NZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip.Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

Rating(A)

Eaton list numberSingle pole 25kA

Eaton list numberTriple pole 25kA1) 2)

Articlenumber

1620253240506380100125160

1) 36kA triple pole also available, change ‘B’ to ‘C’ in list number, ie NZMC1-A1252) 50kA triple pole also available, change ‘B’ to ‘N’ in list number, ie NZMN1-A125

NZMB1-1-AF16NZMB1-1-AF20NZMB1-1-AF25NZMB1-1-AF32NZMB1-1-AF40NZMB1-1-AF50NZMB1-1-AF63NZMB1-1-AF80NZMB1-1-AF100NZMB1-1-AF125–

–NZMB1-A20NZMB1-A25NZMB1-A32NZMB1-A40NZMB1-A50NZMB1-A63NZMB1-A80NZMB1-A100NZMB1-A125NZMB1-A160

280987280988280989259075259076259077259078259079259080281230

LZMB1-A160 Outgoing devices – LZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip.Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

Rating(A)

Articlenumber

Eaton list numberTriple pole 25kA1) 2)

1620253240506380100125160

1) 36kA triple pole also available, change ‘B’ to ‘C’ in list number, ie LZMC1-A125-I2) 50kA triple pole also available, change ‘B’ to ‘N’ in list number, ie LZMN1-A125-I

–LZMB1-A20-ILZMB1-A25-ILZMB1-A32-ILZMB1-A40-ILZMB1-A50-ILZMB1-A63-ILZMB1-A80-ILZMB1-A100-ILZMB1-A125-ILZMB1-A160-I

111848111849111850111851111852111853111854111855111856111857

* For circuit breakers details please refer to MCCB catalog

Page 6: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.1 Incoming device ratings up to 250A – outgoing device ratings up to 160A

xPower Plus MCCB panelboards and associated devices

EPBN1BP1 Accessories

Eaton listnumber

SP blanking module NZM1 frame (i.e. order 3 per TP way)Terminal shroud for outgoing MCCB type NZM1 1PTerminal shroud for outgoing MCCB type NZM1 3PShunt trip 208-250AC/DC for NZM1 (excl. 1P)Shunt trip 208-250AC/DC for NZM2/N2Undervoltage release 208–240AC for NZM1 (excl. 1P)Undervoltage release 208–240AC for NZM2/N2

EPBN1BP1NZM1-1-XKSANZM1-XKSANZM1-XAL208-250AC/DCNZM2/3-XA208-250AC/DCNZM1-XUL208-240ACNZM2/3-XU208-240AC

Description

XPPN2BAS200 Base extension kit - bottom mounted

Description Eaton listnumber

200mm high400mm high

XPPN2BAS200XPPN2BAS400

167095152549260021259744259763259471259499

Articlenumber

XPPN2EXT200M Metering extension boxes – top/bottom mounted

Description Eaton listnumber

200mm high with provision for: - 4 meters (72 x 72mm)- 3 indication lamps (ø22.5mm)- 2 selectors switches (ø22.5mm)(Meters/selectors/indication lamps not included)

XPPN2EXT200M 187569

Articlenumber

187578187581

Articlenumber

XPPN2EXT200 Cable extension boxes - top/bottom mounted

Description Eaton listnumber

200mm high400mm high

XPPN2EXT200XPPN2EXT400

187572187575

Articlenumber

Page 7: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

7xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Detailed view of XPPN22508B-MCCB panel board 250A / 8-way (bottom entry)

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 250A – outgoing device ratings up to 160A 1.1

Main incomer connection to busbar stack & detailed view on neutral link

Busbar stack with outgoing devices / protective covers

Busbar stack without outgoing devices / protective covers

Page 8: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

8 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Specification

• Panelboards to IEC61439-1&2. Form 2b

• Busbar system DEKRA certified 50kA lcc, lcw 50kA/1s, 35kA/3s

• IP42 construction

• Enclosure construction made of 1.5mm sheet metal thickness

• Paint color RAL7035 Polyester powder coating

• MCCBs to IEC60947-2. kA ratings shown are Ics=lcu at 400V ac

• Switch disconnectors to IEC60947-3

• 100% neutral busbar

• Fully type tested at operating ambient temperature of 50oC

Features

• 4, 6, 8, 10, 12, 14 or 16 outgoing TP ways

• Outgoing devices; these panelboards utilise two frame sizes of MCCB: NZM2/LZM2 160A–250A TP, and NZM1 SP 16A–125A or NZM1/LZM1 TP 20A–160A

• Tin–plated busbars

• Incomer accessible with closed door

• Can be configured for incomer device at top or bottom of panelboard

• Removable top/bottom gland plates as standard

• Wide range of extension & metering boxes available

See page 21 for dimensions.

XPPN34010B

Description Associatedincoming device

Currentrating (A)

No. of outgoing ways Eaton list numberTop Incomer

Eaton list numberBottom Incomer

Incoming rating up to 400A, outgoing ratings up to 250A

NZM3/LZM3 MCCB or N3/LN3 Switch Discon-nector or direct lugs connection

4 (2 x 250A + 2 x 160A)6 (2 x 250A + 4 x 160A)8 (2 x 250A + 6 x 160A)10 (2 x 250A + 8 x 160A)12 (2 x 250A + 10 x 160A)14 (2 x 250A + 12 x 160A)16 (2 x 250A + 14 x 160A)

400 XPPN34004TXPPN34006TXPPN34008TXPPN34010TXPPN34012TXPPN34014TXPPN34016T

XPPN34004BXPPN34006BXPPN34008BXPPN34010BXPPN34012BXPPN34014BXPPN34016B

• Minimum ordering requirement: panelboard + incoming device + outgoing devices + blanking plates

• Connection kit from incoming device to main bus bar included

Top Entry IncomerBottom Entry Incomer

NZMN3-A400 MCCB incoming device

• 50kA

• Select appropriate incomer device from table below

• Maximum cable capacity 240mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, Magnetic trip adjustment 6 to 10 x In

3-pole NZM3

LZM3

320400400320400400

NZMN3-A320NZMN3-A400NZMN3-VE400LZMN3-A320-ILZMN3-A400-ILZMN3-AE400-I

109669109670259132111966111967111970

187652187653187654187655187656187657187658

187546187547187548187549187550187551187552

Poles Incoming device type

Current rating (A)

Articlenumber

Articlenumber

Articlenumber

Eaton listnumber

1.2 xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 400A – outgoing device ratings up to 250A

Page 9: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

9xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.2

N3-400 Switch disconnector (non-automatic) incoming device

• Select appropriate incomer device from table below

• Maximum cable capacity 240mm2

3-pole N3 switch disconnectorLN3 switch disconnector

400400

N3-400LN3-400-I

266019112008

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

NZMC2-A250 Outgoing devices – NZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

160200250

Rating(A)

Eaton list numberTriple pole 36kA

Eaton list numberTriple pole 50kA

Articlenumber

Articlenumber

NZMC2-A160NZMC2-A200NZMC2-A250

271421271422271423

259092259093259094

NZMN2-A160NZMN2-A200NZMN2-A250

LZMC2-A250 Outgoing devices – LZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

160200250

Rating(A)

Eaton list numberTriple pole 36kA

Eaton list numberTriple pole 50kA

Articlenumber

Articlenumber

LZMC2-A160-ILZMC2-A200-ILZMC2-A250-I

111938111939111940

174442174443174444

LZMN2-A160-ILZMN2-A200-ILZMN2-A250-I

* For circuit breakers details please refer to MCCB catalog

3-pole (1 set per outgoing device) NZM2/LZM2 160250

NZM2-250-XKC

Poles Outgoing device type

Current rating (A)

Articlenumber

Eaton listnumber

Box terminal for outgoing device (to connect with busbar stack)

NZM2-160-XKCNZM2-250-XKC

262240262244

NZMB1-1-AF63and NZMB1-A160

Outgoing devices – NZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

1620253240506380100125160

Rating(A)

Eaton list numberSingle pole 25kA

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

Articlenumber

Articlenumber

NZMB1-1-AF16NZMB1-1-AF20NZMB1-1-AF25NZMB1-1-AF32NZMB1-1-AF40NZMB1-1-AF50NZMB1-1-AF63NZMB1-1-AF80NZMB1-1-AF100NZMB1-1-AF125–

–NZMB1-A20NZMB1-A25NZMB1-A32NZMB1-A40NZMB1-A50NZMB1-A63NZMB1-A80NZMB1-A100NZMB1-A125NZMB1-A160

–NZMC1-A20NZMC1-A25NZMC1-A32NZMC1-A40NZMC1-A50NZMC1-A63NZMC1-A80NZMC1-A100NZMC1-A125NZMC1-A160

280987280988280989259075259076259077259078259079259080281230

283293283294283295271392271393271394271395271396271397283296

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie NZMN1-A125

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 400A – outgoing device ratings up to 250A

Page 10: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

10 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Eaton list number

Article number

Eaton list number

Article number

Metering extension boxes - top/bottom mounted

Description

XPPN3EXT200M

187570200mm high with provision for: - 4 meters (72 x 72mm)- 3 indication lamps (ø22.5mm)- 2 selectors switches (ø22.5mm)(Meters/selectors/indication lamps not included)

XPPN3EXT200M

EPBN1BP1

NZM3-XKA2

Accessories

SP blanking module NZM1 frame (i.e. order 3 per TP way) TP blanking module NZM2 frameTerminal shroud for outgoing MCCB type NZM1 1PTerminal shroud for outgoing MCCB type NZM1 3PTerminal shroud for outgoing MCCB type NZM2 3PShunt trip 208–250AC/DC for NZM1 (excl. 1P) Shunt trip 208–250AC/DC for NZM2/N2Shunt trip 208–250AC/DC for NZM3/N3Undervoltage release 208–240AC for NZM1 (excl. 1P) Undervoltage release 208–240AC for NZM2/N2Undervoltage release 208–240AC for NZM3/N3Tunnel terminal for multicore cable connection without ferrule/cable lug to incoming device3-pole (1 set per incoming device)

Description Eaton list number

EPBN1BP1EPBN2BP3NZM1-1-XKSANZM1-XKSANZM2-XKSANZM1-XAL208-250AC/DCNZM2/3-XA208-250AC/DCNZM2/3-XA208-250AC/DCNZM1-XUL208-240ACNZM2/3-XU208-240ACNZM2/3-XU208-240ACNZM3-XKA2

Article number

167095167096152549260021260038259744259763259763259471259499259499271461

Outgoing devices – LZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

LZMB1-A160

1620253240506380100125160

Rating(A)

Articlenumber

Articlenumber

–LZMB1-A20-ILZMB1-A25-ILZMB1-A32-ILZMB1-A40-ILZMB1-A50-ILZMB1-A63-ILZMB1-A80-ILZMB1-A100-ILZMB1-A125-ILZMB1-A160-I

–LZMC1-A20-ILZMC1-A25-ILZMC1-A32-ILZMC1-A40-ILZMC1-A50-ILZMC1-A63-ILZMC1-A80-ILZMC1-A100-ILZMC1-A125-ILZMC1-A160-I

111848111849111850111851111852111853111854111855111856111857

111888111889111890111891111892111893111894111895111896111897

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie LZMN1-A125-I

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

187579187582

XPPN3BAS200 Base extension kit - bottom mounted

Description

200mm high400mm high

XPPN3BAS200XPPN3BAS400

* For circuit breakers details please refer to MCCB catalog

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 400A – outgoing device ratings up to 250A

Cable extension boxes - top/bottom mounted

Description Eaton list number

Article number

XPPN3EXT200

200mm high400mm high

XPPN3EXT200XPPN3EXT400

187573187576

1.2

Page 11: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

11xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.2xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 400A – outgoing device ratings up to 250A

Detailed view of XPPN34010B-MCCB panel board 400A / 10-way (bottom entry)

Main incomer connection to busbar stack & detailed view on neutral link

Busbar stack with outgoing devices / protective covers

Busbar stack without outgoing devices / protective covers

Page 12: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

12 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.3 xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 630A – outgoing device ratings up to 250A

Specification

• Panelboards to IEC61439-2. Form 2b

• Busbar system DEKRA certified 50kA lcc, lcw 50kA/1s, 35kA/3s

• IP42 construction

• Enclosure construction made of 1.5mm sheet metal thickness

• Paint color RAL7035 Polyester Powder coating

• Outgoing MCCBs to IEC60947-2. kA ratings shown are Ics=lcu at 400V ac

• Incoming MCCB to IEC60947-2 Icu 50kA, Ics 37kA

• Switch disconnectors to IEC60947-3

• 100% neutral busbar

• Fully type tested at operating ambient temperature of 50oC

Features

• 6, 8, 10, 12, 14 or 16 outgoing TP ways

• Outgoing devices; these panelboards utilise two frame sizes of MCCB: NZM2/LZM2 160A–250A TP, and NZM1 SP 16A–125A or NZM1/LZM1 TP 20A–160A

• Tin–plated busbars

• Incomer accessible with closed door

• Can be configured for incomer device at top or bottom of panelboard

• Removable top/bottom gland plates as standard

• Wide range of extension & metering boxes available

See page 21 for dimensions.

NZMN4-AE630

3-pole NZM4 MCCB 630 NZMN4-AE630NZMN4-VE630

265758265768

MCCB incoming device

• 50kA

• Select appropriate incomer device from table below

• Maximum cable capacity 2 x 240mm2

• Adjustable trip. Thermal trip adjustment 0.5 to 1 x In, Magnetic trip adjustment 2 to 12 x In

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

XPPN46312B • Minimum ordering requirement: panelboard + incoming device + outgoing devices + blanking plates

• Connection kit from incoming device to main bus bar included.

Incoming rating 630A,outgoing ratings up to 250A

NZM4 MCCB or direct lugs connection

6 (2 x 250A + 4 x 160A)8 (4 x 250A + 4 x 160A)10 (4 x 250A + 6 x 160A)12 (4 x 250A + 8 x 160A)14 (4 x 250A + 10 x 160A)16 (4 x 250A + 12 x 160A)

630 XPPN46306TXPPN46308TXPPN46310TXPPN46312TXPPN46314TXPPN46316T

XPPN46306BXPPN46308BXPPN46310BXPPN46312BXPPN46314BXPPN46316B

Top Entry IncomerBottom Entry Incomer

Description Associatedincoming device

Currentrating (A)

No. of outgoing ways Eaton list numberTop Incomer

Eaton list numberBottom Incomer

Articlenumber

Articlenumber

187666187667187668187669187534187535

187560187561187562187563187564187565

Page 13: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

13xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.3

NZMN2-A250 Outgoing devices - NZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

Rating(A)

Eaton list numberTriple pole 50kA

Articlenumber

160200250

NZMN2-A160NZMN2-A200NZMN2-A250

259092259093259094

N4-800

3-pole N4 Switch disconnector 800 N4-800 266025

Switch disconnector (non-automatic) incoming device

• Select appropriate incomer device from table below

• Maximum cable capacity 2 x 240mm2

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

LZMN2-A250 Outgoing devices – LZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

160200250

Rating(A)

Eaton list numberTriple pole 50kA

Articlenumber

174442174443174444

LZMN2-A160-ILZMN2-A200-ILZMN2-A250-I

* For circuit breakers details please refer to MCCB catalog

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 630A – outgoing device ratings up to 250A

NZMB1-1-AF63and NZMB1-A160

Outgoing devices - NZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie NZMN1-A125

Rating(A)

Eaton list numberSingle pole 25kA

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

Articlenumber

Articlenumber

1620253240506380100125160

NZMB1-1-AF16NZMB1-1-AF20NZMB1-1-AF25NZMB1-1-AF32NZMB1-1-AF40NZMB1-1-AF50NZMB1-1-AF63NZMB1-1-AF80NZMB1-1-AF100NZMB1-1-AF125–

–NZMB1-A2ONZMB1-A25NZMB1-A32NZMB1-A40NZMB1-A50NZMB1-A63NZMB1-A80NZMB1-A100NZMB1-A125NZMB1-A160

–NZMC1-A20NZMC1-A25NZMC1-A32NZMC1-A40NZMC1-A50NZMC1-A63NZMC1-A80NZMC1-A100NZMC1-A125NZMC1-A160

280987280988280989259075259076259077259078259079259080281230

283293283294283295271392271393271394271395271396271397283296

3-pole (1 set per outgoing device) NZM2/LZM2 160250

NZM2-250-XKC

Poles Outgoing device type

Current rating (A)

Articlenumber

Eaton listnumber

Box terminal for outgoing device (to connect with busbar stack)

NZM2-160-XKCNZM2-250-XKC

262240262244

Page 14: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

14 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Outgoing devices – LZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

LZMB1-A160

1620253240506380100125160

Rating(A)

Articlenumber

Articlenumber

–LZMB1-A20-ILZMB1-A25-ILZMB1-A32-ILZMB1-A40-ILZMB1-A50-ILZMB1-A63-ILZMB1-A80-ILZMB1-A100-ILZMB1-A125-ILZMB1-A160-I

–LZMC1-A20-ILZMC1-A25-ILZMC1-A32-ILZMC1-A40-ILZMC1-A50-ILZMC1-A63-ILZMC1-A80-ILZMC1-A100-ILZMC1-A125-ILZMC1-A160-I

111848111849111850111851111852111853111854111855111856111857

111888111889111890111891111892111893111894111895111896111897

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie LZMN1-A125-I

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

1.3 xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 630A – outgoing device ratings up to 250A

Metering extension boxes - top/bottom mounted

Description Eaton listnumber

XPPN4EXT200M

200mm high with provision for: - 4 meters (72 x 72mm)- 3 indication lamps (ø22.5mm)- 2 selectors switches (ø22.5mm)(Meters/selectors/indication lamps not included)

XPPN4EXT200M

Articlenumber

187571

XPPN4BAS200 Base extension kit - bottom mounted

Description Eaton listnumber

200mm high400mm high

XPPN4BAS200XPPN4BAS400

Articlenumber

187580187583

EPBN1BP1 Accessories

Description

SP blanking module NZM1 frame (i.e. order 3 per TP way)TP blanking module NZM2 frameTerminal shroud for outgoing MCCB type NZM1 1PTerminal shroud for outgoing MCCB type NZM1 3PTerminal shroud for outgoing MCCB type NZM2 3PShunt trip 208–250AC/DC for NZM1 (excl. 1P)Shunt trip 208–250AC/DC for NZM2/N2Shunt trip 110V–240VAC for NZM4/N4Undervoltage release 208–240AC for NZM1 (excl. 1P)Undervoltage release 208–240AC for NZM2/N2Undervoltage release 208-240AC for NZM4/N4Tunnel terminal for multicore cable connection without ferrule to incoming device3-pole (1 set per incoming device)Module plate for cable lug connection to incoming device3-pole (1 set per incoming device)

Eaton listnumber

EPBN1BP1EPBN2BP3NZM1-1-XKSANZM1-XKSANZM2-XKSANZM1-XAL208-250AC/DCNZM2/3-XA208-250AC/DCNZM4-XA208-250AC/DCNZM1-XUL208-240ACNZM2/3-XU208-240ACNZM4-XU208-240ACNZM4-XKA

NZM4-XKM1

Articlenumber

167095167096152549260021260038259744259763266451259471259499266193266836

266814

NZM4-XKA

NZM4-XKM1

Cable extension boxes - top/bottom mounted

Description Eaton listnumber

XPPN4EXT200

200mm high400mm high

XPPN4EXT200XPPN4EXT400

Articlenumber

187574187577

Page 15: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

15xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.3xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 630A – outgoing device ratings up to 250A

Detailed view of XPPN46312B-MCCB panel board 630A / 12-way (bottom entry)

Internal view of busbar stack with outgoing devices / protective covers

Door closed Door opened

Page 16: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

16 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 800A – outgoing device ratings up to 250A

Specification

• Panelboards to IEC61439-2. Form 2b

• Busbar system DEKRA certified 50kA lcc, lcw 50kA/1s, 35kA/3s

• IP42 construction

• Enclosure construction made of 1.5mm sheet metal thickness

• Paint color RAL7035 Polyester Powder coating

• Outgoing MCCBs to IEC60947-2. kA ratings shown are Ics=lcu at 400V ac

• Incoming MCCB to IEC60947-2 Icu 50kA, Ics 37kA

• Switch Disconnectors to IEC60947-3

• 100% neutral busbar

• Fully type tested at operating ambient temperature of 50oC

Features

• 8, 12 or 18 outgoing TP ways

• Outgoing devices; these panelboards utilise two frame sizes of MCCB: NZM2/LZM2 160A –250A TP, and NZM1 SP 16A–125A or NZM1/LZM1 TP 20A–160A

• Tin–plated busbars

• Incomer accessible with closed door

• Can be configured for incomer device at top or bottom of panelboard

• Removable top/bottom gland plates as standard

• Wide range of extension & metering boxes available

See page 21 for dimensions.

XPPN48008B • Minimum ordering requirement: panelboard + incoming device + outgoing devices + blanking plates

• Connection kit from incoming device to main bus bar included.

Incoming rating 800A,outgoing ratings up to 250A

NZM4 MCCB 8 (4 x 250A + 4 x 160A)12 (4 x 250A + 8 x 160A)18 (4 x 250A + 14 x 160A)

800 XPPN48008TXPPN48012TXPPN48018T

XPPN48008BXPPN48012BXPPN48018B

N4-800

3-pole N4 Switch disconnector 800 N4-800 266025

Switch disconnector (non-automatic) incoming device

• Select appropriate incomer device from table below

• Maximum cable capacity 2 x 240mm2

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

NZMH4-AE800

3-pole NZM4 MCCB 800 NZMH4-AE800NZMH4-VE800

265764265774

MCCB incoming device

• 50kA

• Select appropriate incomer device from table below

• Maximum cable capacity 2 x 240mm2

• Adjustable trip. Thermal trip adjustment 0.5 to 1 x In, Magnetic trip adjustment 2 to 12 x In

Poles Incoming device type

Current rating (A)

Articlenumber

Eaton listnumber

Top Entry IncomerBottom Entry Incomer

1.4

Description Associatedincoming device

Currentrating (A)

No. of outgoing ways Eaton list numberTop Incomer

Eaton list numberBottom Incomer

Articlenumber

Articlenumber

187536187537187538

187566187567187568

Page 17: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

17xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.4xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 800A – outgoing device ratings up to 250A

NZMN2-A250 Outgoing devices - NZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

Rating(A)

Eaton list numberTriple pole 50kA

Articlenumber

160200250

NZMN2-A160NZMN2-A200NZMN2-A250

259092259093259094

NZMB1-1-AF63and NZMB1-A160

Outgoing devices - NZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie NZMN1-A125

Rating(A)

Eaton list numberSingle pole 25kA

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

Articlenumber

Articlenumber

1620253240506380100125160

NZMB1-1-AF16NZMB1-1-AF20NZMB1-1-AF25NZMB1-1-AF32NZMB1-1-AF40NZMB1-1-AF50NZMB1-1-AF63NZMB1-1-AF80NZMB1-1-AF100NZMB1-1-AF125–

–NZMB1-A2ONZMB1-A25NZMB1-A32NZMB1-A40NZMB1-A50NZMB1-A63NZMB1-A80NZMB1-A100NZMB1-A125NZMB1-A160

–NZMC1-A2ONZMC1-A25NZMC1-A32NZMC1-A40NZMC1-A50NZMC1-A63NZMC1-A80NZMC1-A100NZMC1-A125NZMC1-A160

280987280988280989259075259076259077259078259079259080281230

283293283294283295271392271393271394271395271396271397283296

* For circuit breakers details please refer to MCCB catalog

LZMN2-A250 Outgoing devices – LZM2 frame MCCBs (Mandatory to add box terminal accessory for outgoing device to connect with busbar stack) (see below)

• Maximum cable capacity 185mm2

• Adjustable trip. Thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

160200250

Rating(A)

Eaton list numberTriple pole 50kA

Articlenumber

174442174443174444

LZMN2-A160-ILZMN2-A200-ILZMN2-A250-I

NZM2-250-XKC Box terminal for outgoing device (to connect with busbar stack)

3-pole (1 set per outgoing device) NZM2/LZM2 160250

Poles Outgoing device type

Current rating (A)

Articlenumber

Eaton listnumber

NZM2-160-XKCNZM2-250-XKC

262240262244

Page 18: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

18 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

LZMB1-A160 Outgoing devices – LZM1 frame MCCBs

• Maximum cable capacity 70mm2

• Single pole fixed trip. Triple pole thermal trip adjustment 0.8 to 1 x In, magnetic trip adjustment 6 to 10 x In

1620253240506380100125160

Rating(A)

Articlenumber

Articlenumber

–LZMB1-A20-ILZMB1-A25-ILZMB1-A32-ILZMB1-A40-ILZMB1-A50-ILZMB1-A63-ILZMB1-A80-ILZMB1-A100-ILZMB1-A125-ILZMB1-A160-I

–LZMC1-A20-ILZMC1-A25-ILZMC1-A32-ILZMC1-A40-ILZMC1-A50-ILZMC1-A63-ILZMC1-A80-ILZMC1-A100-ILZMC1-A125-ILZMC1-A160-I

111848111849111850111851111852111853111854111855111856111857

111888111889111890111891111892111893111894111895111896111897

1) 50kA triple pole also available, change 'C' to 'N' in list number, ie LZMN1-A125-I

Eaton list numberTriple pole 25kA

Eaton list numberTriple pole 36kA1)

XPPN4EXT200 Cable extension boxes - top/bottom mounted

Description Eaton listnumber

200mm high400mm high

XPPN4EXT200XPPN4EXT400

187574187577

Articlenumber

XPPN4BAS200 Base extension kit - bottom mounted

Description Eaton listnumber

200mm high400mm high

XPPN4BAS200XPPN4BAS400

187580187583

Articlenumber

EPBN1BP1 Accessories

Description Eaton listnumber

EPBN1BP1EPBN2BP3NZM1-1-XKSANZM1-XKSANZM2-XKSANZM1-XAL208-250AC/DCNZM2/3-XA208-250AC/DCNZM4-XA208-250AC/DCNZM1-XUL208-240ACNZM2/3-XU208-240ACNZM4-XU208-240ACNZM4-XKA

NZM4-XKM1

SP blanking module NZM1 frame (i.e. order 3 per TP way)TP blanking module NZM2 frameTerminal shroud for outgoing MCCB type NZM1 1PTerminal shroud for outgoing MCCB type NZM1 3PTerminal shroud for outgoing MCCB type NZM2 3PShunt trip 208–250AC/DC for NZM1 (excl. 1P)Shunt trip 208–250AC/DC for NZM2/N2Shunt trip 110V–240VAC for NZM4/N4Undervoltage release 208–240AC for NZM1 (excl. 1P)Undervoltage release 208–240AC for NZM2/N2Undervoltage release 208-240AC for NZM4/N4Tunnel terminal for multicore cable connection without ferrule to incoming device3-pole (1 set per incoming device)Module plate for cable lug connection to incoming device3-pole (1 set per incoming device)

167095167096152549260021260038259744259763266451259471259499266193266836

266814

Articlenumber

NZM4-XKA

NZM4-XKM1

XPPN4EXT200M Metering extension boxes - top/bottom mounted

Description Eaton listnumber

200mm high with provision for: - 4 meters (72 x 72mm)- 3 indication lamps (ø22.5mm)- 2 selectors switches (ø22.5mm)(Meters/selectors/indication lamps not included)

XPPN4EXT200M 187571

Articlenumber

1.4 xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 800A – outgoing device ratings up to 250A

Page 19: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

19xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.4xPower Plus MCCB panelboards and associated devicesIncoming device ratings up to 800A – outgoing device ratings up to 250A

Detailed view of XPPN48008B-MCCB panel board 800A / 8-way (bottom entry)

Door closed Door opened

Internal view of busbar stack with outgoing devices / protective covers

Page 20: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

20 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

PANELBOARD DIMENSIONAL DRAWINGS .............................................................................................................. 21

250A PANELBOARD DIMENSIONAL DRAWINGS (Bottom / Top Entry ) ............................................................... 22

400A PANELBOARD DIMENSIONAL DRAWINGS (Bottom / Top Entry ) ............................................................... 23

630A PANELBOARD DIMENSIONAL DRAWINGS (Bottom / Top Entry ) ............................................................... 24

800A PANELBOARD DIMENSIONAL DRAWINGS (Bottom / Top Entry ) ............................................................... 25

METERING EXTENSION BOX, EXTENSION BOX & BASE EXTENSION KIT DIMENSIONAL DRAWINGS ............ 26

1.5

1.5 Technical data

Page 21: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

21xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

250

400

630

800

4

6

8

10

12

14

16

4

6

8

10

12

14

16

6

8

10

12

14

16

8

12

18

XPPN22504B

XPPN22506B

XPPN22508B

XPPN22510B

XPPN22512B

XPPN22514B

XPPN22516B

XPPN34004B

XPPN34006B

XPPN34008B

XPPN34010B

XPPN34012B

XPPN34014B

XPPN34016B

XPPN46306B

XPPN46308B

XPPN46310B

XPPN46312B

XPPN46314B

XPPN46316B

XPPN48008B

XPPN48012B

XPPN48018B

XPPN22504T

XPPN22506T

XPPN22508T

XPPN22510T

XPPN22512T

XPPN22514T

XPPN22516T

XPPN34004T

XPPN34006T

XPPN34008T

XPPN34010T

XPPN34012T

XPPN34014T

XPPN34016T

XPPN46306T

XPPN46308T

XPPN46310T

XPPN46312T

XPPN46314T

XPPN46316T

XPPN48008T

XPPN48012T

XPPN48018T

950

1040

1130

1220

1315

1410

1500

1100

1190

1280

1370

1465

1560

1650

1445

1555

1645

1740

1835

1925

1640

1820

2090

650

650

650

650

650

650

650

750

750

750

750

750

750

750

850

850

850

850

850

850

850

850

850

173

173

173

173

173

173

173

203

203

203

203

203

203

203

205

205

205

205

205

205

205

205

205

664

754

844

934

1029

1124

1214

814

904

994

1084

1179

1274

1364

1159

1269

1359

1454

1549

1639

1354

1534

1804

Rating (A) Number of ways PanelboardBottom Entry

PanelboardTop Entry

Dimensions (mm)A C DB

Panelboard dimensions (*)

Meter Extension boxBottom / Top

Cable Extension boxBottom / Top

Base Extension Kit

200200200200200200400400400200200200400400400

650750850650750850650750850650750850650750850

126156174126156174126156174126156174126156174

526626726526626726526626726526626726526626726

7210210272102102721021027610612476106124

Dimensions (mm)A C D EB

Extension boxes dimensions (**)

Description Eaton listnumber

XPPN2EXT200MXPPN3EXT200MXPPN4EXT200MXPPN2EXT200XPPN3EXT200XPPN4EXT200XPPN2EXT400XPPN3EXT400XPPN4EXT400XPPN2BAS200XPPN3BAS200XPPN4BAS200XPPN2BAS400XPPN3BAS400XPPN4BAS400

67117167------------

58108158------------

194.5244294.5------------

F G H

(**) For the details of dimensions (A,B,C,D,E,F,G,H) refer to page 26

Technical dataPanelboard dimensional drawings 1.5

(*) For the details of dimensions (A,B,C,D) refer to pages 22 to 25

Page 22: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

22 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Technical data250A Panelboard dimensional drawings (Bottom/Top Entry)

Bottom entry

Top entry

1.5

Page 23: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

23xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

1.5Technical data

400A Panelboard dimensional drawings (Bottom / Top Entry)

Bottom entry

Top entry

Page 24: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

24 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Technical data630A Panelboard dimensional drawings (Bottom/Top Entry)1.5

Bottom entry

Top entry

Page 25: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

25xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Technical data800A Panelboard dimensional drawings (Bottom / Top Entry) 1.5

Bottom entry

Top entry

Page 26: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

26 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES

Technical dataMetering extension box, extension box & base extension kit dimensional drawings

Metering extension box

Cable extension box

Base extension kit - bottom mounted

1.5

Page 27: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings
Page 28: Providing safety, reliability and performance in commercial and … Plus MCCB PB... · 2018-04-07 · 6 xPOWER PLUS MCCB PANELBOARDS AND ASSOCIATED DEVICES 1.1 Incoming device ratings

Key Contact Regional Offices

UAE

Middle East Headquarters

Techno Park, Jebel Ali (South)P.O. Box 261768Dubai, United Arab EmiratesTel: + 971 4 806 6100Fax:+ 971 4 889 4813

KuwaitShayma TowerMezzanine FloorOmar Bin Al Khattab StreetSharq, KuwaitTel : + 965 22253606/7Fax: + 965 22253608

Saudi ArabiaKing Abdullah Street (Ex. Dhahran St.)Dhahran Center, 1st Floor Office #101P.O. Box 620Al-Khobar 31952Saudi ArabiaTel : +966-13-882-5424/882-5680Fax : +966-13-882-5732

LebanonSin El FilSaydet Al Wardiyeh streetBeirut Symposium building2nd floor - Office 2ATel / Fax: +961 1 494711

QatarEaton CorporationFinancial Square BuildingBuilding 2, Floor 2 , Office 3C Ring RoadDoha, Qatar

Saudi ArabiaSaad Al-Ajlan Trade Center 1st Floor Office #9, Olaya Main StreetP. O. Box 19651Riyadh 11445 – K.S.A.Tel : +966-11-460-2275/288-6238 Fax : +966-11-460-2291

JordanAmman-Mekka & Madina streets intersectionAl-Haramien intersectionAl Hajar Al Aswad Cplx /Al Hussainy Bldg.3rd floor - office 306Tel: + 962 6 5542538

Oman 109, Maktabi Building,Near Zakher Mall, Al Khuwair,PO Box 1982, PC 111 CPO,Oman.Tel : +968 24391973Fax : +968 24483801

Eaton

Version 0, Nov 2016