Proudly Made in the U.S.A. warranty - BuildSite€¦ · .400 1.250 part o.a. patent pendin g 9 -...
Transcript of Proudly Made in the U.S.A. warranty - BuildSite€¦ · .400 1.250 part o.a. patent pendin g 9 -...
www.adatile.com • 800-372-0519
Proudly Made in the U.S.A.5-Year
warranty
Cast-In-PlaCe (wet-set) RePlaCeable taCtIle
Cast-In-PlaCe (wet-set) RePlaCeable taCtIle2
Proudly Made in the U.S.A.
In stock colors
Blue15187
Yellow33538
Seattle Yellow23594
Safety Red31350
Dark Gray36081
Clay Red22144
Black37038
White37875
Brick Red20109
US Patents**www.adatile.com/patents
3
www.adatile.com • 800-372-0519 www.adatile.com • 800-372-0519
Cast-In-PlaCe RePlaCeable taCtIle
Installation ProcedureBe sure to read and understand all of these instructions before you begin.
A. The physical characteristics of the concrete shall be as specified in the contract documents while maintaining a slump range of 4-7 inches to permit the solid placement of the ADA Cast-In-Place Replaceable Tactile Unit (ADAREP) in the wet cement.
B. The concrete shall be poured and finished level, true and smooth to the required dimensions prior to the placement of the ADAREP unit.
C. Place the ADAREP unit 6-8 inches from the curb line. Working in a grid pattern, tamp the ADAREP unit into the wet concrete using a rubber mallet and a piece of wood. Continue this process until all of the air has been released, and the ADAREP unit surface is flush with the surrounding area. IMPORTANT: Avoid striking the surface of the ADAREP unit directly.
D. Following the placement, the ADAREP unit elevation should be checked to the adjacent surface with a straight edge. The ADAREP unit elevation should be consistent with the Contract Drawings and Specifications. Any required adjustments must be made prior to the time when the concrete begins to set.
E. IMPORTANT NOTIcE TO INsTAllER: To allow for expansion and contraction, after tile is installed, use a 1/4” finish edge trowel around entire perimeter. On a continous run, be sure to space each unit 1/8” apart.
F. When you are confident that the ADAREP unit is in place and no further ad-justments are needed, place a cinder block on both ends, if necessary, to hold the ADAREP unit in place while the concrete sets.
G. During and after the ADAREP unit installation, as well as the concrete curing stage, no walking or external forces can be placed on the ADAREP unit. The area must be protected from pedestrian traffic until concrete is cured. The ADAREP Warning Surface will be ready for pedestrian traffic within 2-4 hours.
H. Be sure to remove plastic protective covering from the face of the ADAREP Unit once the concrete is cured. *Not recommended or warrantied for asphalt installation.
Do not cut cast-In-Place Replaceable Tactile. Use an appropriate sized tactile or Radius Tactile to fit the requirement.
Contact manufacturer for more details.
PRODUCT SIZES 2’x3’ 2’x4’ 2’x5’ 3’x4’ 3’x5’
APPLICATION
Fresh Pour concrete Ramps
& Replacement
Pull-Strength6200 P.S.I.
4
www.adatile.com • 800-372-0519
Cast-In-PlaCe RePlaCeable taCtIle
Replacement Procedure
View additional photos, drawings and specifications on our website: www.adatile.com.
Call (800) 372-0519 with any questions.
Be sure to read and understand all of these instructions before you begin.
A. Lift the existing composite bolt cap from each anchor location on the ADA Cast-In-Place Replaceable Tactile unit (ADAREP) with a flat head screw driver.
B. Remove the existing 1/2” x 1½” heavy duty steel bolts and washers from each anchor location on the ADAREP unit with a ratchet. Save & reuse.
C. Tap around all sides of the ADAREP unit and across the middle with a rubber mallet, working in a grid pattern.
D. Pry the existing ADAREP unit from the concrete ramp with a small prybar, working around the edges until it can be lifted cleanly away.
E. Be sure to remove all small debris and dust from the existing impression in the concrete ramp.
IMPORTANT: Be careful not to get debris into anchor locations.
F. Replace new ADAREP unit, of same size and orientation, into impression in concrete ramp. Lightly tamp down the ADAREP unit with a rubber mallet and a piece of wood. Continue this process until the ADAREP unit is set firmly into existing impression in concrete ramp.
IMPORTANT: Avoid striking the ADAREP unit directly.
G. Bolt existing 1/2” x 1½” heavy duty steel bolts and washers back into each anchor location on new ADAREP unit.
H. Snap a new composite bolt cap provided, into each anchor location on the ADAREP unit. The ADAREP unit is ready for pedestrian traffic immediately after installation is complete.
(WET-SET)
US Patents**www.adatile.com/patents
5
www.adatile.com • 800-372-0519
DOME GEOMETRYIn accordance with ADA Regulations for Detectable Warning on Curb Ramps: Raised truncated domes with a diameter of nominal 0.9”, a height of nominal 0.2” and a center-to-center spacing of 2.35”.
PANEL DIMENSIONSADA Cast-In-Place Replaceable Tactile units (ADAREP) are available in 24” x 36”, 24” x 48”, 24” x 60”, 36” x 48” and 36” x 60” sizes. ADAREP units may also be custom configured to accommodate specific project requirements. ADAREP units measure ¼” nominal thickness and feature a ⅜” thick x 1” wide perimeter “flange.”
MATERIALA durable exterior grade homogenous glass, carbon and fiberglass reinforced composite material which is colorfast and UV stable. The color of the ADAREP unit is uniform throughout and does not rely on any type of paint coating to achieve color stability. Standard colors include: Federal Yellow, Seattle Yellow, White, Brick Red, Clay Red, Safety Red, Blue, Dark Gray and Black. For superior wheelchair, walker and shopping cart mobility, truncated domes have a center-to-center (horizontally and vertically) spacing of 2.35 inches.
PHYSICAL CHARACTERISTICSCompressive Strength 28,900 psi ASTM D 695Flexural Strength 29,300 psi ASTM D 790Water Absorption .07% ASTM D 570Slip Resistance 1.18 Dry, 1.05 Wet ASTM C 1028Flame Spread Index 20 ASTM E 84Salt Spray No Change (200 hours) ASTM B 117Chemical Stain Testing No Deterioration ASTM 1308Abrasion Resistance 549 ASTM C 501Accelerated Weathering Delta E<5.0 (2,000 hours) ASTM G 155Tensile Strength 11,600 psi ASTM D 638Load Bearing at 16,000 lbs. No Damage AASHTO-H20Freeze/Thaw/Heat No Disintegration ASTM C 1026
24.000
TYP.
60.000°
21.600
1.200
14.400
1.250
PART O.A.
PATENT PENDING
9 - EQUAL SPACES
PART O.A.
15 - EQUAL SPACES NOTE: US PATENT PENDING APPEARS ON TOP SIDE OF PART AS SHOWN.
AIR VENTS AROUND THEOUTSIDE EDGES OF PANEL
B B
.090 DEG. POINTS.045 HIGH TYP.
VIEW -B
.500DIA. TOP OF DOMES
.900DIA. TYP.
0.870
0.200
0.245
0.625
0.250
0.062
0.312
0.875
0.6250
0.250
R0.250
1.375
1.125DIA.(4)
DIA.(4)
HEX HEAD BOLTS & WASHER 4-PL.
CAP COVER 2.350
2.350
VIEW-D
(4)
(4)
36.00027.429
34.286
ColorThroughout
Recessed Anchor
Location
5-Yearwarranty
INCIDENTALS Fasteners: ½” x 1½”
heavy duty steel bolts and washers.
Anchors: 1½” corrosion resistant concrete inserts.
WARRANTYADAREP units shall be guaranteed in writing for a period of five (5) years from date of contract’s final completion. The guarantee includes breakage and deformation of the tactile warning surface material.
www.adatile.com • 800-372-0519
Cast-In-PlaCe RePlaCeable taCtIle
Inline Dome Pattern
6
www.adatile.com • 800-372-0519
TYP.
.090 DEG. POINTS
.045 HIGH TYP.
VIEW -B
DIA. TOP OF DOMES
DIA. TYP.
DIA. (8)
DIA. (8)
CAP COVER
VIEW -B 3 x SIZE
(8)
(8)
HEX HEAD BOLTS & WASHER 8-PL.
9 - EQUAL SPACES
15 - EQUAL SPACES
TOP VIEW
A
SIDE VIEW
BOTTOM VIEW
AIR VENTS LOCATED ON
THE ENDS OF THE TWS UNIT
AU
S PA
TEN
T #
7,77
9,58
1
60.000°
.450
.900
0.062
0.875
0.62500.250
R0.250
1.375
1.125
24.00021.6001.20014.400
1.250
NOTE:
(800)372-0519
N.Billerica, Ma. 01862
2.350
2.350
VIEW-D
VIEW - " D" 2 x SIZE
FIELD DOT 7 DOME LAYOUT
WET SET ADA STD REPLACEABLE TACTILE
WARNING SURFACE UNIT
2.350" IN LINE TRUNCATED DOME PATTERN
PART SIZE 24" x 36"
PLANS AND DETAILS
SECTION A-A
1.200
36.000
27.429
34.286
8-BOLT LOCATIONS
ADA-REP2436 P.O. Box 3
0.22
0.7220.2000.245
0.500
0.967
TACTILE WARNING SURFACE
2436NV8REP_
SMC COMPOSITE
DATE
DRAWING NO.
MATERIAL
TRADE
PART NO.
PROJECT
U.S
. Pat
ents
*
*ww
w.a
datil
e.co
m/p
aten
ts
www.adatile.com
Cast-In-PlaCe RePlaCeable taCtIle
24”x36” (610 x 914mm) Tile2.35” (59.7 mm) Dome Spacing
(WET-SET)
7
www.adatile.com • 800-372-0519
(8)
(8)(8)
HEX H
EAD
BOLTS &
WA
SHER 8-PL.
VIEW -B 3 x SIZE
CAP CO
VER
(8)D
IA.
(8)D
IA.
DIA
. TYP.
DIA
. TOP O
F DO
MES
.045 HIG
H TYP.
.090 DEG
. POIN
TS
TYP.
TOP VIEW
20 - EQUAL SPACES
9 - EQUAL SPACES
SIDE VIEW
BOTTOM VIEW
VIEW -B
AIR VENTS LOCATED ON
THE ENDS OF THE TWS UNIT
AA
US PATEN
T # 7,779,581
1.125
1.375
0.250R
0.2500.6250
0.875
0.062
.900
.45060.000°
0.967 24.000
48.000
45.714
1.250
21.60014.400
1.200
18.286
20.571
2.286
VIEW - " D" 2 x SIZE
FIELD DOT 7 DOME LAYOUT
2.350
2.350
SECTION A-A
VIEW-D 1.200
WET SET ADA REPLACEABLE TACTILE
WARNING SURFACE UNIT
2.350" IN LINE TRUNCATED DOME PATTERN
PART SIZE 24" x 48"
PLANS AND DETAILS
8-BOLT LOCATIONS
ADA-REP2448
NOTE:
0.22
9.14299.1429
0.500
0.245
0.2000.722
TACTILE WARNING SURFACE
2448NV8REP_
SMC COMPOSITE
DATE
DRAWING NO.
MATERIAL
TRADE
PART NO.
PROJECT
(800)372-0519
N.Billerica, Ma. 01862
P.O. Box 3
U.S. Patents*
*ww
w.adatile.com
/patents
www.adatile.com
24”x48” (610 x 1219mm) Tile2.35” (59.7 mm) Dome Spacing
www.adatile.com • 800-372-0519
Cast-In-PlaCe RePlaCeable taCtIle
8
(11)
(11)(11)
HEX
HEA
D B
OLT
S &
WAS
HER
11-
PL.
VIEW
-B 3
x S
IZE
CAP
CO
VER
(11)
DIA
.(11)
DIA
.
DIA
. TYP
.
DIA
. TO
P O
F D
OM
ES
.045
HIG
H T
YP.
.090
DEG
. PO
INTS
TYP.
9 - EQUAL SPACES
TOP VIEW
25 - EQUAL SPACES
SIDE VIEW
BOTTOM VIEW
VIEW -B
AIR VENTS LOCATED ON
THE ENDS OF THE PANEL
US
PATE
NT
# 7,
779,
581
BB
1.12
5
1.37
5
0.25
0R
0.2500.6250
0.875
0.062
.900
.450
60.0
00°
0.967
1.250
1.20014.400
SECTION B-B
VIEW - " D" 2 x SIZE
FIELD DOT 7 DOME LAYOUT
2.350
2.350
VIEW-D
57.143
21.60024.000
1.200
WET SET ADA REPLACEABLE TACTILE
WARNING SURFACE UNIT
2.350" IN LINE TRUNCATED DOME PATTERN
PART SIZE 24" x 60"
PLANS AND DETAILS
11-BOLT LOCATIONS
ADA-REP2460
NOTE:
0.22
0.500
0.2450.200
0.722
TACTILE WARNING SURFACE
2460NV11REP_
SMC COMPOSITE
6.31
46.
314
18.2
8613
.714
18.2
86
60.0
00
DATE
DRAWING NO.
MATERIAL
TRADE
PART NO.
PROJECT
(800)372-0519
N.Billerica, Ma. 01862
P.O. Box 3
U.S
. Pat
ents
*
*ww
w.a
datil
e.co
m/p
aten
ts
www.adatile.com
24”x60” (610 x 1524mm) Tile2.35” (59.7 mm) Dome Spacing
www.adatile.com • 800-372-0519
Cast-In-PlaCe RePlaCeable taCtIle
(WET-SET)
9
www.adatile.com • 800-372-0519
DRAWING NO.
REV. NO.
SEE MATERIAL LIST
DETECTABLE WARNING SURFACE
PROJECT
MATERIAL
TRADE
SCALE
4
PART NO.
DESCRIPTION
ITEM
3 2 1
PART NO.
QT'Y
AA
2.350
2.350
AIR
VE
NTS
AR
OU
ND
THE
O
UTS
IDE
ED
GE
S O
F PAN
EL
BO
TTOM
VIE
W
36.000
33.750 1.1251.12515 - EQUAL SPACES
13.500 13.500
48.000
18.286
20.571
2.28645.714
1.143
1.143
20 - EQ
UA
L SPA
CE
S
MATERIAL LIST
FULL SIZE
WARNING SURFACE UNIT
WET SET ADA REPLACEABLE TACTILE
2.375" IN LINE TRUNCATED DOME PATTERN
PLANS AND DETAILS
AS NOTED
SECTION B-B
SID
E V
IEW
PAR
T O.A
.
VIE
W-D
VIE
W-B
PART O.A.
VIEW - " D" 2 x SIZE
FIELD DOT 13 ON DOME LAYOUT
PART SIZE 36" x 48"
(12)
(12)(12)
0.500
0.562
0.245
0.2000.722
1.125
1.375
0.250R
0.2500.6250
0.875
0.062 .900
.45060.000°
HEX H
EAD
BOLTS &
WA
SHER 12-PL.
VIEW -B 3 x SIZE
CAP CO
VER
(12)D
IA.
(12)D
IA.
DIA
. TYP.
DIA
. TOP O
F DO
MES
.045 HIG
H TYP.
.090 DEG
. POIN
TS
TYP.
0.967
(800)372-0519
N.Billerica, Ma. 01862
P.O. Box 3
U.S. Patents*
*ww
w.adatile.com
/patents
www.adatile.com
www.adatile.com • 800-372-0519
36”x48” (914 x 1219mm) Tile2.35” (59.7 mm) Dome Spacing
Cast-In-PlaCe RePlaCeable taCtIle
10
www.adatile.com • 800-372-0519
2.350
2.350
36.000
33.7501.125 1.12515 - EQUAL SPACES
PART O.A.
VIEW - " D" 2 x SIZE
FIELD DOT 13 ON DOME LAYOUT
U.S
. Pat
ents
*
*ww
w.a
datil
e.co
m/p
aten
ts
13.50013.500
DRAWING NO.
REV. NO.
SEE MATERIAL LIST
DETECTABLE WARNING SURFACE
PROJECT
MATERIAL
TRADE
SCALE
4
PART NO.
DESCRIPTION
ITEM
321
PART NO.
QT'Y
MATERIAL LIST
FULL SIZE
WARNING SURFACE UNIT
WET SET ADA REPLACEABLE TACTILE
2.375" IN LINE TRUNCATED DOME PATTERN
PLANS AND DETAILS
AS NOTED
BO
TTO
M V
IEW
VIEW
-D
VIE
W-B
59.429
16.000
18.286
16.000
AIR
VEN
TS A
ROU
ND
TH
EO
UTS
IDE
EDG
ES O
F PA
NEL
57.143
20 -
EQU
AL
SPAC
ES
1.143
1.143
PART SIZE 36" x 60"
SEC
TIO
N B
-B
SID
E VI
EW
"B"
"B"
(12)
(12)(12)
0.500
0.562
0.245
0.2000.722
1.12
5
1.37
5
0.25
0R
0.2500.6250
0.875
0.062.900
.450
60.0
00°
HEX
HEA
D B
OLT
S &
WA
SHER
12-
PL.
VIEW
-B 3
x S
IZE
CAP
COVE
R
(12)
DIA
.
(12)
DIA
.
DIA
. TYP
.
DIA
. TO
P O
F D
OM
ES
.045
HIG
H T
YP.
.090
DEG
. PO
INTS
TYP.
0.967
(800)372-0519
N.Billerica, Ma. 01862
www.adatile.com
P.O. Box 3
36x60” (914 x 1524mm) Tile2.35” (59.7 mm) Dome Spacing
Cast-In-PlaCe RePlaCeable taCtIle
(WET-SET)
11
www.adatile.com • 800-372-0519 4/13