Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI...

18

Transcript of Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI...

Page 1: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples
Page 2: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 2

Table of Contents Introduction and Scope .................................................................................................................................... 5

Representative Sampling ............................................................................................................................ 6 Incremental and Representative Sampling Design………………………………………………….5 Random Sampling ........................................................................................................................................... 6

Procedures for Sampling Usable Marijuana ........................................................................................... 6 Planning............................................................................................................................................................... 6 Equipment and Supplies ............................................................................................................................. 7 Records and Documentation ..................................................................................................................... 7 Sampling Records/Field Data ................................................................................................................... 8 Sampling a Harvest Lot of Usable Marijuana ..................................................................................... 8

Sample Preservation, Handling and Storage ....................................................................................... 10 Preparation of the Composite Sample ............................................................................................... 10

Quality Assurance/Quality Control ......................................................................................................... 10 Field QC ............................................................................................................................................................. 11 Field Duplicates ............................................................................................................................................ 11 Demonstration of Capability .................................................................................................................. 11 Sampler Qualifications .............................................................................................................................. 12 Field Audits ..................................................................................................................................................... 12 Auditing Checks ............................................................................................................................................ 12

References ........................................................................................................................................................... 13

Appendix 1 – Definitions ............................................................................................................................... 14

Appendix 2 – Recommended Sampling Guidelines ......................................................................... 17

Page 3: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 3

Acknowledgements

Version 1.0 of this document was authored by the Cannabis Sub-Committee with input from Technical Experts and approved by the ORELAP Executive Board. Revision 3.0 was authored and reviewed by NEFAP/GLP sampling experts. See Revision 2.0 for original committee authorship. Authorship and Technical Expert credit is as follows:

ORELAP Cannabis Sub-Committee Facilitator (Non-Authorship) Sarah Barnard Oregon Health Authority.

ORELAP Cannabis Sampling Sub-Committee Members (Authorship): Nancy Osterbauer Ph.D. Oregon Department of Agriculture Plant Health Program Manager

Sara Krepps Oregon DEQ Laboratory and Assessment Division Technical Organic Manager

Jeremy Sackett Cascadia Labs Co-founder & Director of Operations

Camille Holladay Synergistic Pesticide Laboratory Lab Director

Eric Wendt Green Leaf Lab Chief Science Officer Dennis Wells ORELAP Technical Advisory Committee BSK Asssociates Sid Price Greenhause Analytical

Jes Kristof Phylos Bioscience Laboratory Director

Technical Expert Authorship, Input, and/or Review Marlene Moore Advanced Systems Inc. TNI NEFAP Co

Kim Watson, RQAP-GLP Stone Environmental

Page 4: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 4

TNI NEFAP committee Justin Brown Environmental Monitoring and Technologies Inc. TNI NEFAP committee

Shannon Swantek Oregon Health Authority ORELAP Compliance Specialist Lizbeth Garcia Oregon Health Authority Compliance Specialist Christopher Redman Oregon DEQ Laboratory Quality Officer Gary Ward Oregon Health Authority ORELAP Program Manager

ORELAP Executive Board

Brian Boling Oregon DEQ Laboratory and Assessment Division Laboratory Manager Kathleen Wickman Oregon Department of Agriculture Laboratory Laboratory Manager John Fontana Oregon Health Authority Public Health Lab Laboratory Manager

Page 5: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 5

Introduction and Scope

Laboratory analysis relies on sampling to characterize a larger batch. Hence, the process of taking a representative sample is the beginning of laboratory analysis.

For the purposes of this document, a batch is defined as “a definite quantity of usable marijuana from a harvest lot” identified by a batch number or other unique identifier, every portion of which is assumed to be uniform, within permitted tolerances.” Oregon Administrative Rule (OAR) 333-007-0320 describes the testing requirements for Usable Marijuana.

To reliably provide the laboratory with a representative sample, standard sampling methods must be applied with consistency. In addition, sampling practices and devices must be “correct” for the matrix. This controls variable factors in the sampling procedure, which may introduce error or bias resulting in a non-representative sample. A certain amount of random error is intrinsic to all measurements and may be minimized by close adherence to well documented standard procedures.

Production error is the responsibility of the producer of the Usable Marijuana product. Sampling error must be controlled in order to obtain a representative sample of the defined batch. This is accomplished by maintaining the sample identity within the defined batch, prevention of contamination of the sample, and consistent use of standard sampling methods and equipment. If proper controls are in place for sample collection, the laboratory report produced from the testing of the sample should reflect the quality of the batch within recognized tolerances at the time of sampling.

This protocol will focus on standard and correct sampling practices and sampling devices. The laboratory must meet the client needs for uncertainty, risk, and liability in the sampling contract. It is strongly recommended that the laboratories encourage clients to mitigate risk of uncertainty in representativeness by increasing the number of individually analyzed samples for each test. The specifications in the contract are met by creating a site specific sampling plan or process specific sampling plan that uses statistical design for each project to meet the confidence interval requested by the client. Unless the contract states otherwise, a laboratory need only collect the minimum number of samples required in OAR 333-007-0360 and as recommended in this protocol.

Prior to any sample increments being taken a sampler must receive a test order form as required by OAR 333-007-0315.

Incremental and Representative Sampling Design

Accurate and thorough recordkeeping is another essential aspect of the sampling procedure to connect the batch to the sample increments or composite samples and, eventually, to the laboratory report. At a minimum, a sampling report shall accompany the sample, which shows the harvest and batch information including producer, product type, batch size, batch number, name and address of where sampled, the number of containers sampled, number of sample increments collected, the sampler’s name, and the date sampled. It is always necessary for the sampler to keep a copy of the sampling report. A thorough record of the sample is best maintained on a form specifically designed for that purpose.

Page 6: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 6

Representative Sampling

When sampling a batch, the sampler shall check for any signs of non-uniformity.

Some obvious indicators may be different types or sizes of containers, variations in marks and labels, or mixed batch numbers. During sampling, the sampler shall look for differences in the usable marijuana being sampled such as color, shape, size, and treatment. By definition, the batch must be uniform for all factors that appear on the label; hence, variations in the product may indicate non-uniformity in the batch and that any sample drawn may not be representative for testing. The sampler shall note these anomalies in the sample collection report.

General procedural guidelines that apply to all sampling include: 1. Gaining access to the entire batch; 2. Use of appropriate sampling equipment and consistently following procedures; 3. Taking equal portions for each sample increment; 4. Randomly or systematically taking sample increments throughout the batch; 5. Obtaining a minimum number of sample increments, which will be based on batch size; and 6. Recording all observations and procedures used while collecting the sample increments on an

appropriate sampling form.

Random Sampling

As specified in the sampling plan, sample increments should be randomly selected from different locations within a container or set of containers. Laboratories must develop procedures describing how to:

1. Assign location numbers within containers; 2. Use a random number generator to determine which location to sample; and 3. Document where each sample increment was sampled and the volume collected from each

increment.

Assign divisions based on the type of container in the site specific sampling plan. Use a random number generator with the higher number equal to the number of divisions for the container. When there are multiple containers use existing or arbitrary order of containers to assign numbers to the total of “divisions multiplied by total number of containers” (divisions x # containers = total number of random increments) and record in the sampling report. The laboratory must have details in its SOP or Sampling Plan, from appropriate industry reference where possible, on how it will achieve random sampling in an unclear decision unit.

Procedures for Sampling Usable Marijuana

Planning

Prior to beginning the sampling procedure, the sampler shall survey the site to identify the conditions

Page 7: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 7

under which the Usable Marijuana is being kept, as this will determine the sampling plan. All sampling must be performed by personnel employed by an ORELAP accredited laboratory and must be in accordance with OAR 333-007-0360 and OAR 333-064-0100.

The testing requirements for Usable Marijuana are in OAR 333-007-0320. The requirements for sampling and sample size are in OAR 333-007-0360. Per Authority or Commission request or client request, other analyses may require sampling and must be part of the planning process. In cases where Usable Marijuana will be sold or transferred to a processor or processing site, analysis may occur prior to the drying and curing steps. To ensure representativeness, the sampling plan must be designed such that each flower bud in the batch has an equal chance of being selected. The sample size must be sufficient to complete all analyses required, but shall in no case be less than 0.5% of the weight of the batch. The maximum batch size is 15 lbs.

Equipment and Supplies

• Sampling equipment such as spoons, spatulas, transfer pipettes, or other matrix specific tools • Tongs • Corers • Teri-wipes, or equivalent • Field balance (Capable of 0.01 g measurements) • Calibrated Verification Weights appropriate to verify accuracy of field balance • Cleaning supplies – solvent, bleach, 70% Ethanol • Gloves (powder-free, nitrile, sterile) • Mylar Bags (For final sample transport and storage) And/Or • Amber Glass jars (For final sample transport and storage)

Records and Documentation

Laboratories shall maintain standard operating procedures (SOP) that accurately reflect current sampling activities.

• The SOP shall be readily accessible to all pertinent personnel. • The SOP shall clearly indicate the effective date of the document, the revision number, and the

signature of the approving authority. • The sampling SOP shall use these protocols as minimum requirements and must include

additional detail specific to laboratory procedures. Any changes, including use of a selected option, shall be documented and included on the sampling form. In cases where the published method has been modified or where the referenced method is ambiguous or provides insufficient detail, these changes or clarifications shall be clearly described.

• All documents shall be controlled and retained in accordance with the TNI Environmental Laboratory standard as defined in 333-007-0310.

The ORELAP accredited laboratory shall maintain sampling plans (2009 TNI ELV1M2 5.7). These documents must be made available at their location of use. Sampling plans shall be based on appropriate statistical methods and shall address factors to be controlled to ensure the subsequent laboratory test results accurately reflect the composition of the batch. Standardized Sampling Plans can be included in the SOP however specialized client requests or products may require additional

Page 8: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 8

information. Any deviation from or addition to the sampling plan must be documented in detail and shall be included in the final report.

Sampling Records/Field Data

In addition to collecting the sample, a sampling report form must be made for the batch sampled and must include any observations made while taking the sample. This documentation shall include the following information:

• Name and address of producer including licensee or registrant number; • Product type; • Total mass of batch; • Unique laboratory batch ID#,METRC batch ID #, and/or OHA batch ID#; as designated • Total container number; • Number of sample increments; • Number of containers sampled; • Number of sample containers collected; • Total mass sampled; • Sampling plan ID and revision date; • Sampling Procedure ID and revision date; • Description of equipment used; • Place where sampled; • Date sampled; • ORELAP Laboratory Identification number; • Sampler’s identification and/or signature; • Name of responsible party for the batch and transport information; • Receiving laboratory and types of tests required or requested.

While procuring the sample, in the absence of METRC procedures that contain the below information, the laboratory must create a Chain of Custody form with the following information:

• Sampler’s name • Lab License Number • Sample Identification (Lab ID number) if assigned before arrival at laboratory • Sampling Date/Time • Mass and Location of increment samples • Final Mass of composite sample • Custody transfer signatures • Custody Transfer Dates/Times If any of the above information requested on the sampling report form is unavailable, indicate “N/A” in the appropriate space. All sampling report forms must be signed by the sampler.

Sampling a Batch of Usable Marijuana

1. Locate the batch to be sampled. 2. Review the container label information for harvest lot number, producer, and other pertinent

information. Each harvest lot must be separated into batches of 15 lbs. or less and must be

Page 9: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 9

assigned a unique batch number by the grower. Do not sample if a unique batch number is not available.

3. Determine the number of containers in the batch and the batch size. Visually verify the batch size for each container. Do not sample if the batch size is unavailable or exceeds 15 lbs. for a container.

4. Determine the number of containers from which sample increments must be collected (Appendix 2).

5. Select the appropriate sampling tool to ensure that it reaches all portions of the container. 6. Collection instruments must be clean prior to use to prevent cross- contamination of sample

increments. Sampling tools which appear to be dirty or otherwise compromised shall not be used. To prevent contamination, sampling tools may be cleaned and sealed at the laboratory prior to use or may be cleaned in the field between batches using an appropriate solvent and decontaminant to prevent cross contamination of batches during sampling. Results from cleaning procedure tests must be below the reporting limit of the target analyte(s) for the associated analyses. Decontamination waste must be collected and properly disposed of if not used for analysis.

Note: Samplers must take extreme care if sampling from multiple sites in one day to ensure contaminants, pathogens, or organisms are not transferred between facilities. The sampler may clean sampling equipment in the field between samplings at a single facility. However, the sampler is required to bring enough sets of sampling equipment to use a new set at each facility visited. All field equipment shall be returned to the laboratory following sampling and cleaned according to the laboratory’s procedures. Where aseptic technique is required, apply the FDA Aseptic Sample guidelines (Investigations Operations Manual Subchapter 4.3.6) when taking samples:

7. Visually inspect each test sample increment to assess uniformity; 8. If non-uniformity is identified, record observation in the sampling report. It is expected with

Usable Marijuana to have variable sizes of flowers. When drawing sample increments, approximately equal amounts of product are to be taken with each probing and from each container. Care must be taken by the sampler to not damage the portion of the product which is not being collected.

9. Combine all sample increments to form the composite sample. 10. Ensure sufficient sample increments are taken to meet sample size requirements for

all analytical method(s) being performed. 11. Seal and label the composite sample with the following minimum requirements:

• Laboratory license number • Unique identifier for sampling event • Sampling date and name of sampler • Producer’s license or registration number • Harvest lot and batch numbers • Label “PRODUCT NOT TESTED” in bold capital letters in minimum 12 point font.

12. Apply a custody seal to the sample container in a manner which prevents the product from being tampered with or transferred prior to testing. This seal may contain the laboratory sample identification number.

13. Complete the sampling report while at the sampling location as well as an appropriate chain of custody form as outlined in 2009 TNI EL V1M2 5.8.1 through 5.8.7.

14. Forward the sample and sampling report to the laboratory or other designated location using packaging appropriate for secure and timely transport.

Page 10: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 10

15. Record the sampling event in the OLCC seed to sale system under the licensee number for recreational marijuana or record in the laboratory’s records the registrant number for tracking medicinal marijuana.

Sample Preservation, Handling and Storage

Preparation of the Composite Sample

1. Transport the sample to the analysis laboratory following OLCC license regulation for transport. Note: The existing regulation does not permit shipping in any form such as USPS or FedEx.

2. The laboratory must have detailed procedures on maintaining custody and sample integrity during transport. These procedures should take into consideration controlling temperature and other environmental factors.

3. Submit the composite sample to the laboratory in its entirety. 4. Composite samples must always be identified by labeling or marking the sample container to

associate them with the batch from which they originated and with the sampling report. Containers for sample transport must be designed to prevent damage, contamination, spillage, or commingling of the sample during transport. The required container for sampling is a glass, amber jar with a PTFE-lined lid or a Mylar bag. A tamper-proof seal is required and must be marked with the sampler’s name, date, and sample number.

Forwarding Samples to the Primary and/or Re-testing Laboratory

1. Forward the composite sample to the laboratory or other designated location using packaging appropriate for secure transport.

2. Protect the sample from moisture and temperature extremes. 3. Include all documentation with the sample. 4. Forward the sample by the most expedient, secure, and legal means to ensure that the

sample continues to be representative of the harvest lot sampled and the chain of custody is accounted for to protect its integrity.

Quality Assurance/Quality Control

Sampling plans shall be designed to meet specified sample quality criteria. This includes using a sampling plan that meets a 95% confidence level for representative sampling and limits the fundamental sampling error. The most common way to achieve this is by increasing the number of sample increments to compensate for normal batch heterogeneity. It is recommended that a minimum of ten (10) sample increments be taken for the sample to be considered a representative decision unit for Usable Marijuana.

The sampler must be prepared to collect adequate sample mass for all analyses requested by the producer. This must include adequate sample mass for re-testing in the event a sample fails a criterion as well as adequate sample mass for any quality control samples required by the laboratory, such as duplicates or matrix spikes.

Page 11: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 11

Field QC

Field sampling equipment shall be certified clean prior to use by the laboratory. Cleaning techniques will vary depending upon the desired analysis. In general, sampling equipment must be sterile for microbiology samples and clean for chemistry samples. The laboratory shall perform cleanliness checks on each batch of sampling equipment prior to taking that equipment into the field. Results from cleaning procedure tests must be below the reporting limit of the target analyte(s) for the associated analyses. If cleanliness checks fail, the sampling equipment must be re-cleaned, sterilized and tested. Field Duplicates Field Duplicates are recommended for any Usable Marijuana sampling event, but not required. The Field Duplicate must be collected using the same procedure and contain the same number of sample increments as the Primary Sample. The lab must have documentation of the client request for a Field Duplicate with any client specified Quality objectives and precision limits must meet the client’s need. Equipment Blanks Equipment rinse blank samples provide a QC check on the potential for cross contamination by measuring the effectiveness of the decontamination procedures on the sampling equipment. An equipment blank is required to validate equipment cleaning procedures for all required analyses. It is recommended but not required that an equipment blank is collected upon each sampling event to demonstrate the equipment was not introduced to contamination after cleaning. The equipment rinse blank samples consist of analyte-free matrix, as applicable, rinsed across sample collection and processing equipment. If the analytes of interest are detected in the equipment rinse blank samples, the detected concentrations will be compared to the associated sample results to evaluate the potential for contamination. The Equipment Blank must pass the required analysis at <LOQ for cleaning validation. If the Equipment Blank is collected at the sampling event, the lab must have detail in the sampling plan or procedures as to how to evaluate it and what actions to take if the evaluation demonstrates unacceptable results.

Demonstration of Capability

Prior to acceptance and institution of any method for which data will be reported, a satisfactory initial demonstration of capability (IDOC) is required. The laboratory shall have a documented procedure for performing the IDOC. The IDOC will be repeated: 1) every time there is a change in personnel or method, and, 2) when the method has not been performed by the laboratory or sampler within a 12-month period. This procedure shall employ one of the following approaches to demonstrating capability:

1. Comparison of replicate samples within a defined Relative Standard Deviation (%RSD)1.

1 Standard Methods 20th Edition; 1020 B Quality Control, 11. QC Calculations, a. Initial Calibration.

Page 12: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 12

2. Comparison of a sample collected to that of one collected by personnel with an existing IDOC within a defined RPD.

Thereafter, ongoing continuing demonstration of capability (CDOC) as per the quality control requirements referenced in the method is required annually. The laboratory shall have a documented procedure for performing the CDOC. The laboratory shall retain documentation verifying CDOC for each sampler and make this documentation available to ORELAP upon request.

Sampler Qualifications

Basic qualifications for samplers of Usable Marijuana are:

• Physically able to perform the duties of a sampler; • No conflict of interest; • Must be employed by an ORELAP accredited laboratory • Pass initial and ongoing demonstrations of capability; • Licensed to transport the required quantity of Usable Marijuana items

Education and training for samplers:

• Initial classroom training: 8-hours of training, including principles, procedures, and policies of

sampling; Initial Training must be performed by an Instructor that has demonstrated competency in performing and instructing on the sampling methods referenced or equivalent. After personnel goes through initial training, they are qualified to train others in their organization.

• Field or on-the-job training: 8-hours of training on various sampling techniques; • Continuing education: 8-hours of periodic refresher training annually.

Field Audits

The laboratory shall adopt an ongoing system for performing audits of field activities. Field audits must be conducted periodically and in accordance with a predetermined schedule and procedure. The goal of the field audit is to verify that the sampling operation continues to comply with the requirements of the regulations and is being performed according to the laboratory’s sampling SOP. Audits are to be carried out by trained and qualified personnel who are, wherever resources permit, independent of the activity to be audited. The field audit shall address all elements of the sampling activities and shall be documented. When field audit findings cast doubt on the effectiveness of the operations or on the correctness or validity of the field sampling activities, the associated laboratory shall take timely corrective action, and shall notify customers in writing if investigations show that test results may have been affected. Laboratory management shall have a policy that specifies the time frame for notifying clients of events that cast doubt on the validity of the results. Follow up audit activities shall verify and document the implementation and effectiveness of any corrective actions taken as a result of the field audit.

Auditing Checks

1. Using audit checklists:

Page 13: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 13

a. Review sampling and performance records from the preceding year for deficiencies in the application of sampling protocol;

b. Observe the sampler conducting sampling procedures; c. Have the auditor and sampler collect samples from the same harvest lot for evaluation and

comparison of results. 2. Record any deficiencies and initiate corrective action.

References

Association of American Seed Control Officials. 2006. AASCP Handbook on Seed Sampling, Rev. Ed. 2006 (W.R. Guerke, Ed.). 41 pp.

FDA (2015). Salmonella sampling plan. Investigations Operations Manual 2015.

ASTA. Clean, Safe Spices. Guidance from the American Spice Trade Association. FDA, Guidelines for Food Spice Labeling. Code of Federal Regulations Title 21, Volume 2. http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfcfr/CFRSearch.cfm?fr=101.2 2)

FDA. The Food Defect Action Levels: Levels of natural or unavoidable defects in foods that present no health hazards for humans. Code of Federal Regulations Title 21, Part 110.

FDA (2015). Subchapter 4.3.6: Aseptic Sample. In: Investigations Operations Manual Chapter 4: Sampling. 106 pp.

Sampling and Sample Handling Working Group FDA, AAFCO, AFDO, APHL and Industry, October 2015. Good Samples: Guidance on Obtaining Defensible Samples.

TNI Environmental Laboratory Standard (2009), Volume 1 Management and Technical Requirements for Laboratories Performing Environmental Analysis.

http://www.nelac-institute.org/content/CSDP/standards.php Oregon Administrative Rules, Marijuana Labeling, Concentration limits, and Testing, Chapter 333, Division 7.

Oregon Administrative Rules, General Requirements Applicable to all Marijuana Licensees, Chapter 845, Division 25.

Standard Methods 20th Edition (1998); 1020 Quality Assurance

Page 14: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 14

Appendix 1 – Definitions

** If there are any inconsistencies between the definitions below and the definitions in OAR 333, Divisions 7 and 64, the definitions in the rules take precedence.

Authority means Oregon Health Authority

Batch means a quantity of Usable Marijuana from a harvest lot. Chain of Custody means the chronological documentation showing the collection, custody, control, transfer, analysis, and disposition of a sample. (Sample tracking document) Commission means the Oregon Liquor Control Commission.

Composite sample means a sample containing all sample increments taken from a batch. Container means a sealed, hard or soft bodied receptacle in which a marijuana item is placed or a physical division of a marijuana batch for random and representative sampling.

Decision Unit (DU) means the material from which the primary sample(s) is collected and to which the inference(s) is made.

Equipment Blank means a sample of analyte-free media, collected after decontamination and prior to sampling, which has been used to rinse the sampling equipment after cleaning to validate cleaning procedure or between sampling batches to demonstrate lack of contamination.

Field Duplicate Sample means sample increments taken in an identical manner to sample increments taken for the primary sample and representative of the same marijuana item being sampled, that is prepared and analyzed separately from the primary sample. Fundamental Sampling Error (FSE) means the results from compositional heterogeneity, which is controlled through the collection of sufficient sample mass (mass is inversely proportional to error). Harvest Lot means a specifically identified quantity of marijuana that is cultivated utilizing the same growing practices and harvested within a 72-hour period at the same location and cured under uniform conditions.

Heterogeneity means the state or quality of being heterogeneous. Heterogeneous means non-uniform or consisting of dissimilar parts or components. Homogeneous means uniform in composition within recognized tolerances.

Label means a tag or other device attached to or written, stamped, or printed on any container or accompanying any batch in bulk stating all required batch information.

Laboratory means a laboratory that is accredited under ORS 438.605 to 438.620 to sample or conduct tests on marijuana items and licensed by the Oregon Liquor Control Commission under ORS475B.560. Marijuana means the plant Cannabis family Cannabaceae, any part of the plant Cannabis family Cannabaceae and the seeds of the plant Cannabis family Cannabaceae. This does not include industrial hemp, as defined in ORS 571.300.

Marijuana item means marijuana, Usable Marijuana, a cannabinoid product or a cannabinoid

Page 15: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 15

concentrate or extract.

ORELAP means the Oregon Environmental Laboratory Accreditation Program.

Primary Sample means a sample composed of sample increments and tested for the required analysis methods.

Producer means a person licensed by the Commission under ORS 475B.070 or a grower registered by the Authority under ORS 475B.420.

Relative Percent Difference means comparing two quantities while taking into account the "sizes" of the things being compared. If any results are <LOQ, the absolute value of the LOQ is used in the equation.

%𝑅𝑅𝑅𝑅𝑅𝑅 = |(𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 − 𝑑𝑑𝑑𝑑𝑠𝑠𝑠𝑠𝑑𝑑𝑑𝑑𝑠𝑠𝑑𝑑𝑠𝑠)|(𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠𝑠 + 𝑑𝑑𝑑𝑑𝑠𝑠𝑠𝑠𝑑𝑑𝑑𝑑𝑠𝑠𝑑𝑑𝑠𝑠)/2 𝑥𝑥 100

Relative standard deviation means the standard deviation expressed as a percentage of the mean recovery, i.e., the coefficient of variation multiplied by 100. If any results are <LOQ, the absolute value of the LOQ is used in the equation.

Standard Deviation

𝑆𝑆 = �∑ (𝑥𝑥𝑖𝑖 − �̅�𝑥)2𝑛𝑛𝑖𝑖=1

(𝑛𝑛 − 1)

Relative Standard Deviation

%𝑅𝑅𝑆𝑆𝑅𝑅 = S�̅�𝑥

𝑥𝑥 100 S = standard deviation. n = total number of values. 𝑥𝑥𝑖𝑖 = each individual value used to calculate mean. �̅�𝑥 = mean of n values.

Registrant means a person registered with the Authority under ORS475B.420, 475B.435, or ORS 475B.450.

Sterilization means the removal of all microorganisms and other pathogens from a marijuana item by treating it with approved chemicals or subjecting it to high heat.

Representative Sample means a sample obtained according to a sampling procedure designed to ensure that the different parts of a batch or lot or the different properties of a batch or lot are proportionally represented.

Sample means an amount of marijuana item collected by sampling personnel from a registrant or licensee and provided to a laboratory for testing.

Sample Increment means an amount of a marijuana item collected by laboratory personnel from a registrant or licensee that may be combined into a sample for purposes of testing, or in the case of a control study, is tested individually..

Page 16: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 16

Sample Quality Criteria (SQC) means a series of statements that clarify program technical and quality needs to support defensible decisions, including statement of the question to be answered, definition of the decision unit, and the desired confidence in the inference. Sealed means secured to provide authenticity or integrity.

Usable Marijuana means the dried and cured leaves and flowers of marijuana. Usable Marijuana does not include the seeds, stalks and roots of marijuana or waste material that is a by-product of producing or processing marijuana.

Page 17: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 17

Appendix 2 – Recommended Sampling Guidelines

Sample size Per OAR 333-007-0360, the sample size must be sufficient to complete all analyses required, but shall in no case be less than 0.5% of the weight of the batch. Per OAR 333-007-0350, the maximum batch size is 15 lbs.

The required sample size for a given batch size based on OAR 333-007-0360 varies depending upon the size of the batch (Table 1).

Table 1 – Sample size requirements based on size of batch. Batch size Required sample size

Pounds (lbs) Ounces (oz) Grams (g) ≤1 lbs 0.005 0.08 2.3

1.01 ≤2 lbs 0.010 0.16 4.5 2.01 ≤3 lbs 0.015 0.24 6.8 3.01 ≤4 lbs 0.020 0.32 9.1 4.01 ≤5 lbs 0.025 0.40 11.3 5.01 ≤6 lbs 0.030 0.48 13.6 6.01 ≤7 lbs 0.035 0.56 15.9 7.01 ≤8 lbs 0.040 0.64 18.1 8.01 ≤9 lbs 0.045 0.72 20.4

9.01 ≤10 lbs 0.050 0.80 22.7 10.01 ≤11 lbs 0.055 0.88 25.0 11.01 ≤12 lbs 0.060 0.96 27.3 12.01 ≤13 lbs 0.065 1.04 29.6 13.01 ≤14 lbs 0.070 1.12 31.9 14.01 ≤15 lbs 0.075 1.20 34.2

Sampling a batch 1. When collecting a primary sample from a batch, a minimum of ten (10) sample increments

shall be collected. Collect the sample increments by following different paths through the batch container or by taking the sample increments systematically at well-separated points along a heptagonal pattern.

2. As the batch increases in size, it is necessary to collect additional sample increments to make up the primary sample (Table 2).

Page 18: Protocol for Collecting Samples of Usable Marijuana · Marlene Moore Advanced Systems Inc. TNI NEFAP Co Kim Watson, RQAP-GLP Stone Environmental . Protocol for Collecting Samples

Protocol for Collecting Samples of Usable Marijuana

Page | 18

Table 2 – Minimum number of sample increments for the primary sample based on batch size.

Size of batch (lbs) ≤ 2 ≤ 4 ≤ 6 ≤ 8 ≤ 10

No. of increments 7 7 8 8 9

Size of batch (lbs) ≤ 12 ≤ 14 ≤ 15

No. of increments 9 10 10