Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz...

14
1 of 14 FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S success in “IMPROVING POWER BY DESIGN.” But it doesn't stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these systems will provide superior performance. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine. Digital voltage regulation at ±1%. TEST CRITERIA: PROTOTYPE TESTED NEMA MG1-22 EVALUATION SYSTEM TORSIONALTESTED MOTOR STARTING ABILITY SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro-chip based appliances, such as variable speed HVAC systems. GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ® INCLUDES: Two Line LCD Multilingual Digital Evolution™ Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position. Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation Integrated base tank options are available with run times over 90 hours without having to refuel* Five Year Limited Warranty UL 2200 / UL142 / ULC S601 Listed Meets code requirements for External Vent and Fill ® Diesel Generator Set Protector™ Series Standby Power Rating Model RD015 - 15 kW 60 Hz Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector™ *Assembled in the USA using domestic and foreign parts Meets EPA Emission Regulations CA/MA Emissions Compliant * Time calculated at one-half maximum kW output.

Transcript of Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz...

Page 1: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

1 of 14

FEATURES INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC'S

success in “IMPROVING POWER BY DESIGN.” But it doesn't stop there. Totalcommitment to component testing, reliability testing, environmental testing,destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and otherstandards, allows you to choose GENERAC POWER SYSTEMS with the confidencethat these systems will provide superior performance.

SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on allGenerac models. It provides optimized FAST RESPONSE to changing loadconditions and MAXIMUM MOTOR STARTING CAPABILITY by electronicallytorque-matching the surge loads to the engine. Digital voltage regulation at ±1%.

TEST CRITERIA:

√ PROTOTYPE TESTED √ NEMA MG1-22 EVALUATION √ SYSTEM TORSIONALTESTED √ MOTOR STARTING ABILITY

SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealernetwork provides parts and service know-how for the entire unit, from the engineto the smallest electronic component.

TRUE POWER™ ELECTRICAL TECHNOLOGY: Superior harmonics and sine waveform produce less than 5% Total Harmonic Distortion for utility quality power. This allowsconfident operation of sensitive electronic equipment and micro-chip based appliances,such as variable speed HVAC systems.

GENERAC TRANSFER SWITCHES: Long life and reliability are synonymouswith GENERAC POWER SYSTEMS. One reason for this confidence is that theGENERAC product line includes its own transfer systems and controls for totalsystem compatibility.

®

INCLUDES: Two Line LCD Multilingual Digital

Evolution™ Controller (English/Spanish/ French/Portuguese) with external viewing window for easy indication of generator status and breaker position.

Isochronous Electronic Governor Sound Attenuated Aluminum Enclosure Smart Battery Charger UV / Ozone Resistant Hoses ±1% Voltage Regulation Integrated base tank options are available

with run times over 90 hours without having to refuel*

Five Year Limited Warranty UL 2200 / UL142 / ULC S601 Listed Meets code requirements for External Vent

and Fill

®

Diesel Generator SetProtector™

Series

Standby Power Rating

Model RD015 - 15 kW 60 HzModel RD020 - 20 kW 60 HzModel RD030 - 30 kW 60 Hz

Prot

ecto

r™

*Assembled in the USA using domestic and foreign parts

Meets EPA Emission Regulations

CA/MA Emissions Compliant* Time calculated at one-half maximum kW output.

Page 2: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

2 of 14

15 • 20 • 30 kW application and engineering data

®

Prot

ecto

r™

GENERATOR SPECIFICATIONS

Type SynchronousRotor Insulation Class H (15 & 20 kW) or F (30 kW)Stator Insulation Class HTelephone Interference Factor (TIF) <50Alternator Output Leads 1-Phase Three wireAlternator Output Leads 3-Phase Six wireBearings Single Sealed CartridgeCoupling Direct, Flexible DiscExcitation System DirectTotal Harmonic Distortion < 5%

VOLTAGE REGULATION

Type ElectronicSensing Single PhaseRegulation ± 1%Features Adjustable Voltage & Gain

GOVERNOR SPECIFICATIONS

Type Electronic Isochronous

Steady State Regulation ± 0.25%

ELECTRICAL SYSTEM

Battery Charge Alternator 50 Amp (15 & 20 kW), 65 Amp (30 kW)

Static Battery Charger 2 Amp

Recommended Battery (battery not included)Group 27F, 700 CCA

Group 31, 925 CCA batteries can also be used with 30kW units

System Voltage 12 Volts

ALTERNATOR SPECIFICATIONS

Revolving field heavy duty generatorDirectly connected to the engineOperating temperature rise 120°C above a 40°C ambient Class H insulation is NEMA ratedClass F insulation is NEMA rated All models fully prototype tested

ENCLOSURE FEATURES

Aluminum weather protective enclosureEnsures protection against mother nature. Electrostatically applied textured epoxy paint for added durability.

Enclosed critical grade mufflerQuiet, critical grade muffler is mounted inside the unit to prevent injuries and maximize sound dampening.

Small, compact, attractive Makes for an easy, eye appealing installation.

SAE Sound attenuated enclosure ensures quiet operation.

Page 3: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

of 14

®

Prot

ecto

r™

3

15 • 20 • 30 kW application and engineering data

ENGINE SPECIFICATIONS: 15 & 20 KW

Make Mitsubishi

Model In-line

Cylinders 4

Displacement (Liters) 2.505

Bore (in / mm) 3.46 / 88

Stroke (in / mm) 4.06 / 103

Compression Ratio 22:1

Intake Air System Naturally Aspirated

Cylinder Head Type Cast Iron OHV

Piston Type Aluminum

ENGINE SPECIFICATIONS: 30 KW

Make Perkins

Model In-line

Cylinders 4

Displacement (Liters) 2.216

Bore (in / mm) 3.30 / 84

Stroke (in / mm) 3.94 / 100

Compression Ratio 23.3:1

Intake Air System Turbocharged / Aftercooled

Cylinder Head Type Cast Iron OHV

Piston Type Aluminum

ENGINE LUBRICATION SYSTEM

Oil Pump Type Gear

Oil Filter Type Full flow spin-on canister

Crankcase Capacity (quarts / liters)6.87 / 6.5 - 15 & 20 kW

11.2 / 10.6 - 30 kW

ENGINE COOLING SYSTEMWater Pump Pre-lubed, self-sealing

Fan Speed (rpm)2376 - 15 & 20 kW

1980 - 30 kW

Fan Diameter (in / mm)18.11/460 (15 & 20 kW)

18/457.2 (30kW)Fan Mode Pusher

FUEL SYSTEM—TANK SPECIFICATIONS

Fuel Type Ultra Low Sulfur Diesel Fuel

Fuel Pump Type Mechanical Engine Driven Gear

Injector Type Mechanical

Fuel Supply Line (mm / in) 7.94 / 0.31 (ID)

Fuel Return Line (mm / in)N/A - 15 & 20 kW

4.76/0.19 (ID) - 30 kWFuel Specification ASTM

Fuel Filtering (microns)6—15 & 20 kW

25—30 kW

WEIGHTS AND DIMENSIONS

kW size Tank size Weight (lb / kg)Dimensions (L x W x H)(in / cm)

15 kWExtended 1528 / 693 81 x 31 x 51 / 206 x 79 x 129

95 Gal 1757 / 797 81 x 31 x 65 / 206 x 79 x 165

20 kWExtended 1528 / 693 81 x 31 x 51 / 206 x 79 x 129

95 Gal 1757 / 797 81 x 31 x 65 / 206 x 79 x 165

30 kWExtended 1857 / 842 95 x 35 x 59 / 241 x 89 x 150

132 Gal 2070 / 939 95 x 35 x 68 / 241 x 89 x 173

TANK SPECIFICATIONS Total Capacity Usable Capacity Run Time at 1/2 Load (hrs)

kW size

15 kWExtended Tank (gal / L) 33.5 / 127 32 / 121 3995 Gal Tank (gal / L) 98.5 / 372.9 95 / 359.6 115.8

20 kWExtended Tank (gal / L) 33.5 / 127 32 / 121 3195 Gal Tank (gal / L) 98.5 / 372.9 95 / 359.6 92.2

30 kWExtended Tank (gal / L) 61 / 233 57 / 215 41.6132 Gal Tank (gal / L) 138.5 / 524 132 / 500 96.4

Page 4: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

4 of 14

®

Prot

ecto

r™

15 • 20 • 30 kW application and engineering data

GENERATOR OUTPUT VOLTAGE / KW–60 HZ

kW (standby) Amp (standby) kW (Prime) Amp (Prime) CB Size

RD015120/240 V, 1Ø, 1.0 pf 15 62 12 50 70120/208 V, 3Ø, 0.8 pf 15 52 12 42 60120/240 V, 3Ø, 0.8 pf 15 45 12 36 50

RD020120/240 V, 1Ø, 1.0 pf 20 83 16 67 100120/208 V, 3Ø, 0.8 pf 20 69 16 56 80120/240 V, 3Ø, 0.8 pf 20 60 16 48 70

RD030

120/240 V, 1Ø, 1.0 pf 30 125 24 100 150120/208 V, 3Ø, 0.8 pf 30 104 24 83 125120/240 V, 3Ø, 0.8 pf 30 90 24 72 100277/480 V, 3Ø, 0.8 pf 30 45 24 36 50

SURGE CAPACITY IN AMPS

Voltage Dip @ < 0.4 pf 15% 30%

RD015120/240 V, 1Ø 53 129120/208 V, 3Ø 37 90120/240 V, 3Ø 32 78

RD020120/240 V, 1Ø 87 211120/208 V, 3Ø 59 143120/240 V, 3Ø 51 124

RD030

120/240 V, 1Ø 66 168120/208 V, 3Ø 59 144120/240 V, 3Ø 51 125277/480 V, 3Ø 26 64

ENGINE FUEL CONSUMPTION

gal/hr L/hr

RD015

25% of rated load 0.60 2.2750% of rated load 0.85 3.2275% of rated load 1.10 4.16100% of rated load 1.46 5.53

RD020

25% of rated load 0.77 2.950% of rated load 1.03 3.9075% of rated load 1.46 5.53100% of rated load 1.97 7.46

RD030

25% of rated load 0.97 3.6750% of rated load 1.37 5.1975% of rated load 1.97 7.46100% of rated load 2.77 10.49

Page 5: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

5 of 14

Prot

ecto

r™

15 • 20 • 30 kW operating data

®

POWER ADJUSTMENT FOR AMBIENT CONDITIONSTemperature Deration ...................................................................................................................3% for every 5 °C above 25 °C or 1.7% for every 5 °F above 77 °FAltitude Deration (15 & 30 kW)............................................................................................1% for every 100 m above 915 m or 3% for every 1000 ft above 3000 ftAltitude Deration (20 kW) ....................................................................................................1% for every 100 m above 305 m or 3% for every 1000 ft above 1000 ft

CONTROLLER FEATURES2-Line Plain Text Multilingual LCD Display ..................................................................................................................... Simple user interface for ease of operation.Mode Buttons: Auto....................................................................................................................Automatic Start on Utility failure. Programmable 7 day exerciser.

Manual ...................................................................................... Start with starter control, unit stays on. If utility fails, transfer to load takes place.Off .......................................................................................................................Stops unit. Power is removed. Control and charger still operate.

Ready to Run/Maintenance Message. ................................................................................................................................................................................ StandardEngine Run Hours Indication...............................................................................................................................................................................................StandardProgrammable start delay between 2-1500 seconds ...........................................................................................................Standard (programmable by dealer only)Utility Voltage Loss/Return to Utility Adjustable..................................................................................................................................... From 140-171 V/190-216 VFuture Set Capable Exerciser/Exercise Set Error Warning ....................................................................................................................................................StandardRun/Alarm/Maintenance Logs................................................................................................................................................................................... 50 Events EachEngine Start Sequence ......................................................................................................................Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration)Starter Lock-out ......................................................................................................................... Starter cannot re-engage until 5 seconds after engine has stopped.Smart Battery Charger ........................................................................................................................................................................................................StandardCharger Fault/Missing AC Warning .....................................................................................................................................................................................StandardLow Battery/Battery Problem Protection and Battery Condition Indication.............................................................................................................................StandardAutomatic Voltage Regulation with Over and Under Voltage Protection ................................................................................................................................StandardUnder-Frequency/Overload/Stepper Overcurrent Protection.................................................................................................................................................StandardSafety Fused/Fuse Problem Protection................................................................................................................................................................................StandardAutomatic Low Oil Pressure................................................................................................................................................................................................StandardOvercrank/Overspeed (@ 72 Hz)/RPM Sense Loss Shutdown.............................................................................................................................................StandardHigh Engine Temperature Shutdown .................................................................................................................................................................................. StandardInternal Fault/Incorrect Wiring Protection ........................................................................................................................................................................... StandardCommon External Fault Capability ......................................................................................................................................................................................StandardField Upgradeable Firmware ...............................................................................................................................................................................................StandardLow Coolant Level Shutdown..............................................................................................................................................................................................Standard

ENGINE COOLING

15 kW 20 kW 30 kW

Air flow (inlet air including alternator and combustion air in cfm/cmm) 2750 / 78 2750 / 78 2800 / 79System coolant capacity (gal / liters) 3.0 / 11.4 3.0 / 11.4 2.5 / 9.5Heat rejection to coolant (BTU per hr/MJ per hr) 95,220 / 100.5 95,220 / 100.5 128,638 / 135.7Maximum operation air temperature on radiator (°C/°F) 50 / 122Maximum ambient temperature (°C/°F) 50 / 122

COMBUSTION REQUIREMENTS

Flow at rated power (cfm / cmm) 86.3 / 2.4 86.3 / 2.4 88 / 2.5

SOUND EMISSIONS

Sound output in dB(A) at 23 ft (7 m) with generator in exercise mode* 65Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load* 70

EXHAUST

Exhaust flow at rated output (cfm/cmm) 98.88 / 2.8 98.88 / 2.8 296.6 / 8.4Exhaust temperature at rated output (°C/°F) 482 / 900 482 / 900 499 / 930

ENGINE PARAMETERS

Rated Synchronous RPM 1800HP at rated kW 26.4 33.5 49

Page 6: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

6 of 14

15 • 20 kW installation drawings

®

Prot

ecto

r™

D2.5L G2 Extended Tank (1 of 2)

43

21

43

1

AB

AB

1525

[60.

0]TY

P

631

[24.

8]D

OO

R W

IDTH

TYP

209

[8.2

]E

XH

AU

ST

OU

TLE

T

580

[22.

8]E

XH

AU

ST

OU

TLE

T

1284

[50.

6]O

VE

RA

LLH

EIG

HT

776

[30.

6]O

VE

RA

LL W

IDTH

342

[13.

5]TY

P

177

[7.0

]TY

P

2052

[80.

8]O

VE

RA

LL L

EN

GTH

884

[34.

8]C

EN

TER

OF

GR

AV

ITY

WE

IGH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SE

E N

OTE

5)

GE

NE

RA

TOR

AS

SH

OW

N69

3 [1

528]

WIT

H W

OO

DE

N S

HIP

PIN

G S

KID

731.

6 [1

600]

SE

RV

ICE

ITE

M2.

5LO

IL F

ILL

CA

PR

IGH

T S

IDE

OIL

DIP

STI

CK

RIG

HT

SID

EO

IL F

ILTE

RR

IGH

T S

IDE

OIL

DR

AIN

HO

SE

LEFT

SID

ER

AD

IATO

R D

RA

IN H

OS

ELE

FT S

IDE

CO

OLA

NT

RE

CO

VE

RY

BO

TTLE

LEFT

SID

ER

AD

IATO

R F

ILL

CA

P A

CC

ES

SR

OO

FA

IR C

LEA

NE

R E

LEM

EN

TLE

FT S

IDE

MU

FFLE

RFR

ON

TFA

N B

ELT

EIT

HE

R S

IDE

BA

TTE

RY

LEFT

SID

E

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

EX

TEN

DE

D T

AN

K

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

189

RE

V

BN

/A

BSC

ALE

0.05

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

1/2

REV

BW

INDC

HILL

VER

SION

B.3

NO

TES

: 1.

MIN

IMU

M R

EC

OM

ME

ND

ED

CO

NC

RE

TE P

AD

SIZ

E: 1

092

(43"

) WID

E X

188

7 (7

4.3"

) LO

NG

. R

EFE

RE

NC

E IN

STA

LLA

TIO

N G

UID

E S

UP

PLI

ED

WIT

H U

NIT

FO

R C

ON

CR

ETE

PA

D G

UID

ELI

NE

S.

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES

OF

THE

GE

NE

RA

TOR

FO

R M

AIN

TEN

AN

CE

AN

D S

ER

VIC

ING

. TH

IS U

NIT

MU

ST

BE

INS

TALL

ED

IN A

CC

OR

DA

NC

E W

ITH

CU

RR

EN

T A

PP

LIC

AB

LE N

FPA

37

AN

D N

FPA

70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER

FE

DE

RA

L, S

TATE

, AN

D L

OC

AL

CO

DE

S.

3. C

ON

TRO

L P

AN

EL

/ CIR

CU

IT B

RE

AK

ER

INFO

RM

ATI

ON

: -

SE

E S

PE

CIF

ICA

TIO

N S

HE

ET

OR

OW

NE

RS

MA

NU

AL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ES

S A

SS

EM

BLY

DO

OR

ON

RE

AR

OF

GE

NE

RA

TOR

.4.

RE

MO

VE

TH

E R

EA

R S

TUB

-UP

AN

D R

EA

R E

NC

LOS

UR

E C

OV

ER

PA

NE

L TO

AC

CE

SS

TH

E S

TUB

-UP

AR

EA

S A

S F

OLL

OW

S:

- H

IGH

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G A

C L

OA

D L

EA

D C

ON

DU

IT C

ON

NE

CTI

ON

,

NE

UTR

AL

CO

NN

EC

TIO

N, A

ND

BA

TTE

RY

CH

AR

GE

R 1

20 V

OLT

AC

(0.5

AM

P M

AX

) CO

NN

EC

TIO

N.

- L

OW

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G T

RA

NS

FER

SW

ITC

H C

ON

TRO

L W

IRE

S

AN

D A

CC

ES

SO

RY

RE

LAY

CO

NN

EC

TIO

N (Q

TY 4

)5.

CE

NTE

R O

F G

RA

VIT

Y A

ND

WE

IGH

T M

AY

CH

AN

GE

DU

E T

O U

NIT

OP

TIO

NS

.6.

BO

TTO

M O

F G

EN

ER

ATO

R S

ET

MU

ST

BE

EN

CLO

SE

D T

O P

RE

VE

NT

PE

ST

INTR

US

ION

AN

D R

EC

IRC

ULA

TIO

N O

F D

ISC

HA

RG

E A

IR A

ND

/OR

IMP

RO

PE

R C

OO

LIN

G A

IR F

LOW

.7.

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

LIF

TIN

G W

AR

NIN

GS

.8.

MO

UN

TIN

G B

OLT

S O

R S

TUD

S T

O M

OU

NTI

NG

SU

RFA

CE

SH

ALL

BE

5/8

-11

GR

AD

E 5

(U

SE

STA

ND

AR

D S

AE

TO

RQ

UE

SP

EC

S)

9. M

US

T A

LLO

W F

RE

E F

LOW

OF

INTA

KE

AIR

, DIS

CH

AR

GE

AIR

AN

D E

XH

AU

ST.

SE

E S

PE

C S

HE

ET

FOR

MIN

IMU

M A

IR F

LOW

AN

D M

AX

IMU

M R

ES

TRIC

TIO

N R

EQ

UIR

EM

EN

TS.

10. G

EN

ER

ATO

R M

US

T B

E IN

STA

LLE

D S

UC

H T

HA

T FR

ES

H C

OO

LIN

G A

IR IS

AV

AIL

AB

LE A

ND

TH

AT

DIS

CH

AR

GE

AIR

FR

OM

RA

DIA

TOR

IS N

OT

RE

CIR

CU

LATE

D.

WE

IGH

T: K

G [L

BS

]D

IME

NS

ION

S: M

M [I

NC

H]

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

PE

RIO

DIC

RE

PLA

CE

ME

NT

PA

RT

LIS

TIN

GS

.

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

RE

AR

VIE

W

RE

AR

EN

CLO

SU

RE

C

OV

ER

PA

NE

LS

EE

NO

TE 4

CIR

CU

IT B

RE

AK

ER

S

EE

NO

TE 3

CU

STO

ME

R A

CC

ES

S

AS

SE

MB

LY, C

ON

TRO

L P

AN

EL

AC

CE

SS

, B

ATT

ER

Y C

HA

RG

ER

LO

CA

TED

WIT

HIN

S

EE

NO

TE 4

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RIG

HT

SID

E V

IEW

AN

D L

EFT

SID

ES

DO

OR

ON

FR

ON

T, R

IGH

T, P

ER

DO

OR

, ON

E L

IFT-

OFF

VIS

E A

CTI

ON

LA

TCH

, ON

E

DIM

EN

SIO

NS

CE

NTE

R O

F G

RA

VIT

Y S

EE

NO

TES

5, 7

AN

DLI

FTIN

G P

RO

VIS

ION

(4 P

LAC

ES

)

LIFT

OFF

DO

OR

PR

OV

IDE

S A

CC

ES

S

TO: F

UE

L FI

LL, F

UE

L LE

VE

L G

AU

GE

, N

OR

MA

L V

EN

T, IN

NE

R T

AN

K

EM

ER

GE

NC

Y V

EN

T, O

UTE

R T

AN

K

EM

ER

GE

NC

Y V

EN

T, O

PTI

ON

AL

90%

A

LAR

M A

SS

EM

BLY

, OP

TIO

NA

L 5

GA

LLO

N S

PIL

L B

OX

LEFT

SID

E V

IEW

EX

HA

US

T M

UFF

LER

E

NC

LOS

ED

WIT

HIN

G

EN

ER

ATO

R E

NC

LOS

UR

E

OP

EN

PU

NC

HE

D L

OU

VE

RS

TY

PIC

AL

ON

BO

TH S

IDE

S

OF

FUE

L TA

NK

V

EN

TILA

TIO

N D

UC

T TO

P

RO

VID

E A

DE

QU

ATE

C

RO

SS

-FLO

W O

F A

IR

VE

NTI

LATI

ON

FUE

L TA

NK

V

EN

TILA

TIO

N

DU

CT

BA

TTE

RY

12

VO

LT

NE

GA

TIV

E G

RO

UN

D

TOP

VIE

WRE

MO

VE

CO

VE

R F

OR

A

CC

ES

S T

O R

AD

IATO

R

FILL

CA

P

INTE

RN

AL

DIV

IDE

R P

AN

EL

SE

PA

RA

TES

FU

EL

TAN

K

VE

NTI

LATI

ON

DU

CT

FRO

M T

HE

E

NG

INE

, ALT

ER

NA

TOR

AN

D

EX

HA

US

T S

YS

TEM

RE

MO

VE

PA

NE

L TO

ALL

OW

TA

NK

VE

NTS

TO

TE

RM

INA

TE O

UTS

IDE

OF

THE

GE

NE

RA

TOR

E

NC

LOS

UR

E (C

HE

CK

LO

CA

L A

ND

STA

TE C

OD

E F

OR

A

PP

LIC

AB

ILIT

Y)

Page 7: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

of 14

15 • 20 kW installation drawings

®

Prot

ecto

r™

7

D2.5L G2 Extended Tank (2 of 2)

43

21

43

1

AB

AB

738

[29.

1]

674

[26.

5]

105

[4.1

]S

TUB

-UP

AR

EA

9 [.4]

51 [2.0

]

1817

[71.

5]

100

[3.9

]S

TUB

-UP

AR

EA

1248

[49.

1]TY

P22

4[8

.8]

40[1

.6]

559

[22.

0]639

[25.

2]

1722

[67.

8]

1631

[64.

2]

906

[35.

7]35

7[1

4.0]

231

[9.1

]

107

[4.2

]

210

[8.3

]

269

[10.

6]

292

[11.

5]

464

[18.

3]

574

[22.

6]TY

P

624

[24.

6]TY

P

152

[6.0

]

110

[4.3

]TY

P73

9[2

9.1]

TYP

1368

[53.

9]TY

P19

50[7

6.8]

TYP

2052

[80.

8]

290

[11.

4]FU

EL

TAN

KH

EIG

HT

393

[15.

5]

19[.7

]TY

P73

9[2

9.1]

MTG

CE

NTE

RS

TYP

776

[30.

6]

FUE

L TA

NK

TO

TAL

CA

PA

CIT

Y

127

[33.

5]

US

AB

LE C

AP

AC

ITY

12

1 [3

2]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

EX

TEN

DE

D T

AN

K

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

189

RE

V

BN

/A

BSC

ALE

0.08

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

2/2

REV

BW

INDC

HILL

VER

SION

B.3

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

]D

IME

NS

ION

S: M

M [I

NC

H]

NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

TAN

K IS

LIS

TED

TO

UL1

42 A

ND

ULC

5601

LEFT

SID

E V

IEW

HIG

H A

ND

LO

W

VO

LTA

GE

STU

B-U

P A

RE

A

TOP

VIE

W

INN

ER

TA

NK

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

) INN

ER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

FUE

L LE

VE

L G

AU

GE

/SE

ND

ER

FUE

L FI

LL(2

" NP

T FE

MA

LE)

CU

STO

ME

R O

PTI

ON

(2" N

PT

FEM

ALE

)

OU

TER

TA

NK

LE

AK

DE

TEC

TOR

OU

TER

TA

NK

E

ME

RG

EN

CY

VE

NT

(2" N

PT

FEM

ALE

)

FUE

L S

UP

PLY

16.6

6 [0

.66]

MTG

HO

LES

(8 P

LAC

ES

)S

EE

NO

TE 8

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

W

Page 8: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

8 of 14

15 • 20 kW installation drawings

®

Prot

ecto

r™

D2.5L G2 95 Gal Tank (1 of 2)

43

21

43

1

AB

AB

1525

[60.

0]TY

P

631

[24.

8]D

OO

R W

IDTH

TYP

209

[8.2

]E

XH

AU

ST

OU

TLE

T

580

[22.

8]E

XH

AU

ST

OU

TLE

T

1648

[64.

9]O

VE

RA

LLH

EIG

HT

776

[30.

6]O

VE

RA

LL W

IDTH

706

[27.

8]TY

P

177

[7.0

]TY

P20

52[8

0.8]

OV

ER

ALL

LE

NG

TH

884

[34.

8]C

G

WE

IGH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SE

E N

OTE

5)

GE

NE

RA

TOR

AS

SH

OW

N79

7 [1

757]

WIT

H W

OO

DE

N S

HIP

PIN

G S

KID

835

[184

1]

SE

RV

ICE

ITE

M2.

5LO

IL F

ILL

CA

PR

IGH

T S

IDE

OIL

DIP

STI

CK

RIG

HT

SID

EO

IL F

ILTE

RR

IGH

T S

IDE

OIL

DR

AIN

HO

SE

LEFT

SID

ER

AD

IATO

R D

RA

IN H

OS

ER

IGH

T S

IDE

CO

OLA

NT

RE

CO

VE

RY

BO

TTLE

LEFT

SID

ER

AD

IATO

R F

ILL

CA

P A

CC

ES

SR

OO

FA

IR C

LEA

NE

R E

LEM

EN

TLE

FT S

IDE

MU

FFLE

RFR

ON

TFA

N B

ELT

EIT

HE

R S

IDE

BA

TTE

RY

LEFT

SID

E

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

95 G

AL

EX

T TA

NK

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0028

999

RE

V

BN

/A

ASC

ALE

0.05

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

1/2

REV

AW

INDC

HILL

VER

SION

A.1

NO

TES

: 1.

MIN

IMU

M R

EC

OM

ME

ND

ED

CO

NC

RE

TE P

AD

SIZ

E: 1

092

(43"

) WID

E X

188

7 (7

4.3"

) LO

NG

. R

EFE

RE

NC

E IN

STA

LLA

TIO

N G

UID

E S

UP

PLI

ED

WIT

H U

NIT

FO

R C

ON

CR

ETE

PA

D G

UID

ELI

NE

S.

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES

OF

THE

GE

NE

RA

TOR

FO

R M

AIN

TEN

AN

CE

AN

D S

ER

VIC

ING

. TH

IS U

NIT

MU

ST

BE

INS

TALL

ED

IN A

CC

OR

DA

NC

E W

ITH

CU

RR

EN

T A

PP

LIC

AB

LE N

FPA

37

AN

D N

FPA

70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER

FE

DE

RA

L, S

TATE

, AN

D L

OC

AL

CO

DE

S.

3. C

ON

TRO

L P

AN

EL

/ CIR

CU

IT B

RE

AK

ER

INFO

RM

ATI

ON

: -

SE

E S

PE

CIF

ICA

TIO

N S

HE

ET

OR

OW

NE

RS

MA

NU

AL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ES

S A

SS

EM

BLY

DO

OR

ON

RE

AR

OF

GE

NE

RA

TOR

.4.

RE

MO

VE

TH

E R

EA

R S

TUB

-UP

AN

D R

EA

R E

NC

LOS

UR

E C

OV

ER

PA

NE

L TO

AC

CE

SS

TH

E S

TUB

-UP

AR

EA

S A

S F

OLL

OW

S:

- H

IGH

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G A

C L

OA

D L

EA

D C

ON

DU

IT C

ON

NE

CTI

ON

,

NE

UTR

AL

CO

NN

EC

TIO

N, A

ND

BA

TTE

RY

CH

AR

GE

R 1

20 V

OLT

AC

(0.5

AM

P M

AX

) CO

NN

EC

TIO

N.

- L

OW

VO

LTA

GE

CO

NN

EC

TIO

N IN

CLU

DIN

G T

RA

NS

FER

SW

ITC

H C

ON

TRO

L W

IRE

S

AN

D A

CC

ES

SO

RY

RE

LAY

CO

NN

EC

TIO

N (Q

TY 4

)5.

CE

NTE

R O

F G

RA

VIT

Y A

ND

WE

IGH

T M

AY

CH

AN

GE

DU

E T

O U

NIT

OP

TIO

NS

.6.

BO

TTO

M O

F G

EN

ER

ATO

R S

ET

MU

ST

BE

EN

CLO

SE

D T

O P

RE

VE

NT

PE

ST

INTR

US

ION

AN

D R

EC

IRC

ULA

TIO

N O

F D

ISC

HA

RG

E A

IR A

ND

/OR

IMP

RO

PE

R C

OO

LIN

G A

IR F

LOW

.7.

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

LIF

TIN

G W

AR

NIN

GS

.8.

MO

UN

TIN

G B

OLT

S O

R S

TUD

S T

O M

OU

NTI

NG

SU

RFA

CE

SH

ALL

BE

5/8

-11

GR

AD

E 5

(U

SE

STA

ND

AR

D S

AE

TO

RQ

UE

SP

EC

S)

9. M

US

T A

LLO

W F

RE

E F

LOW

OF

INTA

KE

AIR

, DIS

CH

AR

GE

AIR

AN

D E

XH

AU

ST.

SE

E S

PE

C S

HE

ET

FOR

MIN

IMU

M A

IR F

LOW

AN

D M

AX

IMU

M R

ES

TRIC

TIO

N R

EQ

UIR

EM

EN

TS.

10. G

EN

ER

ATO

R M

US

T B

E IN

STA

LLE

D S

UC

H T

HA

T FR

ES

H C

OO

LIN

G A

IR IS

AV

AIL

AB

LE A

ND

TH

AT

DIS

CH

AR

GE

AIR

FR

OM

RA

DIA

TOR

IS N

OT

RE

CIR

CU

LATE

D.

WE

IGH

T: K

G [L

BS

]D

IME

NS

ION

S: M

M [I

NC

H]

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

PE

RIO

DIC

RE

PLA

CE

ME

NT

PA

RT

LIS

TIN

GS

.

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

TD

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

RE

AR

VIE

W

RE

AR

EN

CLO

SU

RE

C

OV

ER

PA

NE

LS

EE

NO

TE 4

CIR

CU

IT B

RE

AK

ER

S

EE

NO

TE 3

CU

STO

ME

R A

CC

ES

S

AS

SE

MB

LY, C

ON

TRO

L P

AN

EL

AC

CE

SS

, B

ATT

ER

Y C

HA

RG

ER

LO

CA

TED

WIT

HIN

S

EE

NO

TE 4

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RIG

HT

SID

E V

IEW

AN

D L

EFT

SID

ES

DO

OR

ON

FR

ON

T, R

IGH

T, P

ER

DO

OR

, ON

E L

IFT-

OFF

VIS

E A

CTI

ON

LA

TCH

, ON

E

DIM

EN

SIO

NS

CE

NTE

R O

F G

RA

VIT

Y S

EE

NO

TES

5, 7

AN

DLI

FTIN

G P

RO

VIS

ION

(4 P

LAC

ES

)

LIFT

OFF

DO

OR

PR

OV

IDE

S A

CC

ES

S

TO: F

UE

L FI

LL, F

UE

L LE

VE

L G

AU

GE

, N

OR

MA

L V

EN

T, IN

NE

R T

AN

K

EM

ER

GE

NC

Y V

EN

T, O

UTE

R T

AN

K

EM

ER

GE

NC

Y V

EN

T, O

PTI

ON

AL

90%

A

LAR

M A

SS

EM

BLY

, OP

TIO

NA

L 5

GA

LLO

N S

PIL

L B

OX

LEFT

SID

E V

IEW

EX

HA

US

T M

UFF

LER

E

NC

LOS

ED

WIT

HIN

G

EN

ER

ATO

R E

NC

LOS

UR

E

OP

EN

PU

NC

HE

D L

OU

VE

RS

TY

PIC

AL

ON

BO

TH S

IDE

S

OF

FUE

L TA

NK

V

EN

TILA

TIO

N D

UC

T TO

P

RO

VID

E A

DE

QU

ATE

C

RO

SS

-FLO

W O

F A

IR

VE

NTI

LATI

ON

FUE

L TA

NK

V

EN

TILA

TIO

N

DU

CT

BA

TTE

RY

12

VO

LT

NE

GA

TIV

E G

RO

UN

D

TOP

VIE

WRE

MO

VE

CO

VE

R F

OR

A

CC

ES

S T

O R

AD

IATO

R

FILL

CA

P

INTE

RN

AL

DIV

IDE

R P

AN

EL

SE

PA

RA

TES

FU

EL

TAN

K

VE

NTI

LATI

ON

DU

CT

FRO

M T

HE

E

NG

INE

, ALT

ER

NA

TOR

AN

D

EX

HA

US

T S

YS

TEM

RE

MO

VE

PA

NE

L TO

ALL

OW

TA

NK

VE

NTS

TO

TE

RM

INA

TE O

UTS

IDE

OF

THE

GE

NE

RA

TOR

E

NC

LOS

UR

E (C

HE

CK

LO

CA

L A

ND

STA

TE C

OD

E F

OR

A

PP

LIC

AB

ILIT

Y)

Page 9: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

9 of 14

15 • 20 kW installation drawings

®

Prot

ecto

r™

D2.5L G2 95 Gal Tank (2 of 2)

43

21

43

1

AB

AB

738

[29.

1]

674

[26.

5]

105

[4.1

]S

TUB

-UP

AR

EA

9 [.4]

51 [2.0

]

1817

[71.

5]

100

[3.9

]S

TUB

-UP

AR

EA

1248

[49.

1]TY

P22

4[8

.8]

40[1

.6]

559

[22.

0]639

[25.

2]

1722

[67.

8]

1631

[64.

2]

906

[35.

7]35

7[1

4.0]

231

[9.1

]

107

[4.2

]

210

[8.3

]

269

[10.

6]

292

[11.

5]46

4[1

8.3]

574

[22.

6]TY

P

624

[24.

6]TY

P

152

[6.0

]

110

[4.3

]TY

P73

9[2

9.1]

TYP

1368

[53.

9]TY

P19

50[7

6.8]

TYP

2052

[80.

8]

654

[25.

8]FU

EL

TAN

KH

EIG

HT

757

[29.

8]

19[.7

]TY

P73

9[2

9.1]

MTG

CE

NTE

RS

TY

P

776

[30.

6]

FUE

L TA

NK

TO

TAL

CA

PA

CIT

Y

373

[98.

5]

US

AB

LE C

AP

AC

ITY

36

0 [9

5]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.5L

G2

95 G

AL

EX

T TA

NK

ISSU

E D

ATE:

06/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0028

999

RE

V

BN

/A

ASC

ALE

0.08

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

2/2

REV

AW

INDC

HILL

VER

SION

A.1

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

]D

IME

NS

ION

S: M

M [I

NC

H]

NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

TAN

K IS

LIS

TED

TO

UL1

42 A

ND

ULC

5601

LEFT

SID

E V

IEW

HIG

H A

ND

LO

W

VO

LTA

GE

STU

B-U

P A

RE

A

TOP

VIE

W

INN

ER

TA

NK

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

) INN

ER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

FUE

L LE

VE

L G

AU

GE

/SE

ND

ER

FUE

L FI

LL(2

" NP

T FE

MA

LE)

CU

STO

ME

R O

PTI

ON

(2" N

PT

FEM

ALE

)

OU

TER

TA

NK

LE

AK

DE

TEC

TOR

OU

TER

TA

NK

E

ME

RG

EN

CY

VE

NT

(2" N

PT

FEM

ALE

)

FUE

L S

UP

PLY

16.6

6 [0

.66]

MTG

HO

LES

(8 P

LAC

ES

)S

EE

NO

TE 8

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

W

Page 10: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

10 of 14

30 kW installation drawings

®

Prot

ecto

r™

D2.2L G22 Extended Tank (1 of 2)

43

21

43

1

AB

AB

1495

[58.

9]O

VE

RA

LLH

EIG

HT

888

[35.

0]O

VE

RA

LL W

IDTH

365

[14.

4]TY

P

197

[7.8

]TY

P

2424

[95.

4]O

VE

RA

LL L

EN

GTH

1938

[76.

3]TY

P

897

[35.

3]D

OO

R W

IDTH

TYP

173

[6.8

]E

XH

AU

ST

OU

TLE

T

611

[24.

0]E

XH

AU

ST

OU

TLE

T

1029

[40.

5]C

EN

TER

OF

GR

AV

ITY

SE

RV

ICE

ITE

M2.

2LO

IL F

ILL

CA

PR

IGH

T S

IDE

OIL

DIP

STI

CK

RIG

HT

SID

EO

IL F

ILTE

RR

IGH

T S

IDE

OIL

DR

AIN

HO

SE

RIG

HT

SID

ER

AD

IATO

R D

RA

IN H

OS

ELE

FT S

IDE

CO

OLA

NT

RE

CO

VE

RY

BO

TTLE

LEFT

SID

ER

AD

IATO

R F

ILL

CA

P A

CC

ES

SR

OO

FA

IR C

LEA

NE

R E

LEM

EN

TR

IGH

T S

IDE

MU

FFLE

RFR

ON

T S

IDE

FAN

BE

LTE

ITH

ER

SID

EB

ATT

ER

YLE

FT S

IDE

WE

IGH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SE

E N

OTE

5)

GE

NE

RA

TOR

AS

SH

OW

N84

2 [1

857]

WIT

H W

OO

DE

N S

HIP

PIN

G S

KID

888

[195

7]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.2L

G22

EX

TEN

DE

D T

AN

K

ISSU

E D

ATE:

10/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

412

RE

V

BN

/A

CSC

ALE

0.05

0 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

1/2

REV

CW

INDC

HILL

VER

SION

C.1

RA

DIA

TOR

/EX

HA

US

T D

ISC

HA

RG

E A

IR

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

T D

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

NO

TES

: 1.

MIN

IMU

M R

EC

OM

ME

ND

ED

CO

NC

RE

TE P

AD

SIZ

E: 1

194

(47"

) WID

E X

226

1 (8

9") L

ON

G.

RE

FER

EN

CE

INS

TALL

ATI

ON

GU

IDE

SU

PP

LIE

D W

ITH

UN

IT F

OR

CO

NC

RE

TE P

AD

GU

IDE

LIN

ES

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES

OF

THE

GE

NE

RA

TOR

FO

R M

AIN

TEN

AN

CE

AN

D S

ER

VIC

ING

. TH

IS U

NIT

MU

ST

BE

INS

TALL

ED

IN A

CC

OR

DA

NC

E W

ITH

CU

RR

EN

T A

PP

LIC

AB

LE N

FPA

37

AN

D N

FPA

70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER

FE

DE

RA

L, S

TATE

, AN

D L

OC

AL

CO

DE

S.

3. C

ON

TRO

L P

AN

EL

/ CIR

CU

IT B

RE

AK

ER

INFO

RM

ATI

ON

: -

SE

E S

PE

CIF

ICA

TIO

N S

HE

ET

OR

OW

NE

RS

MA

NU

AL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ES

S A

SS

EM

BLY

DO

OR

ON

RE

AR

OF

G

EN

ER

ATO

R4.

RE

MO

VE

TH

E R

EA

R T

AN

K A

ND

RE

AR

EN

CLO

SU

RE

CO

VE

R P

AN

EL

TO A

CC

ES

S T

HE

STU

B-U

P A

RE

AS

AS

FO

LLO

WS

: -

HIG

H V

OLT

AG

E C

ON

NE

CTI

ON

INC

LUD

ING

AC

LO

AD

LE

AD

CO

ND

UIT

CO

NN

EC

TIO

N

NE

UTR

AL

CO

NN

EC

TIO

N, B

ATT

ER

Y C

HA

RG

ER

120

VO

LT A

C (0

.5 A

MP

MA

X) C

ON

NE

CTI

ON

. -

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S IN

CLU

DIN

G T

RA

NS

FER

SW

ITC

H C

ON

TRO

L W

IRE

S5.

CE

NTE

R O

F G

RA

VIT

Y A

ND

WE

IGH

T M

AY

CH

AN

GE

DU

E T

O U

NIT

OP

TIO

NS

.6.

EN

GIN

E S

ER

VIC

E C

ON

NE

CTI

ON

S

OIL

DR

AIN

: 3/8

" NP

T

EX

HA

US

T O

UTL

ET:

2" O

.D.

7. B

OTT

OM

OF

GE

NE

RA

TOR

SE

T M

US

T B

E E

NC

LOS

ED

TO

PR

EV

EN

T P

ES

T IN

TRU

SIO

N A

ND

AN

D R

EC

IRC

ULA

TIO

N O

F D

ISC

HA

RG

E A

IR A

ND

/OR

IMP

RO

PE

R C

OO

LIN

G A

IR F

LOW

.8.

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

LIF

TIN

G W

AR

NIN

GS

.9.

MO

UN

TIN

G B

OLT

S O

R S

TUD

S T

O C

ON

CR

ETE

PA

D S

HA

LL B

E 5

/8-1

1 G

RA

DE

5

(U

SE

STA

ND

AR

D S

AE

TO

RQ

UE

SP

EC

S)

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

P

ER

IOD

IC R

EP

LAC

EM

EN

T P

AR

T LI

STI

NG

S

WE

IGH

T: K

G [L

BS

]D

IME

NS

ION

S: M

M [I

NC

H]

RE

AR

EN

CLO

SU

RE

C

OV

ER

PA

NN

EL,

S

EE

NO

TE 4

CIR

CU

IT B

RE

AK

ER

S

EE

NO

TE 3

CU

STO

ME

R A

CC

ES

S

AS

SE

MB

LY, C

ON

TRO

L P

AN

EL

AC

CE

SS

, B

ATT

ER

Y C

HA

RG

ER

LO

CA

TED

WIT

HIN

S

EE

NO

TE 4

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

WLI

FTIN

G P

RO

VIS

ION

S (4

PLA

CE

S)

SE

E N

OTE

S 5

, 8 A

ND

CE

NTE

R

OF

GR

AV

ITY

DIM

EN

SIO

NS

VIS

E A

CTI

ON

LA

TCH

, ON

E P

ER

D

OO

R, O

NE

LIF

T-O

FF D

OO

R O

N

FRO

NT,

RIG

HT

AN

D L

EFT

SID

ES

LIFT

DO

OR

PR

OV

IDE

S A

CC

ES

S T

O: F

UE

L FI

LL, F

UE

L LE

VE

L G

AU

GE

, NO

RM

AL

VE

NT,

IN

NE

R T

AN

K E

ME

RG

EN

CY

VE

NT,

OU

TER

TA

NK

EM

ER

GE

NC

Y V

EN

T, O

PTI

ON

AL

90%

A

LAR

M A

SS

EM

BLY

, OP

TIO

NA

L 5

GA

LLO

N

SP

ILL

BO

X

RIG

HT

SID

E V

IEW

EX

HA

US

T M

UFF

LER

E

NC

LOS

ED

WIT

HIN

G

EN

ER

ATO

R E

NC

LOS

UR

E

OP

EN

PU

NC

HE

D

LOU

VE

RS

TY

PIC

AL

ON

B

OTH

SID

ES

OF

FUE

L TA

NK

VE

NTI

LATI

ON

D

UC

T TO

PR

OV

IDE

A

DE

QU

ATE

CR

OS

S-F

LOW

O

F A

IR V

EN

TILA

TIO

N

FUE

L TA

NK

V

EN

TILA

TIO

N D

UC

T

LEFT

SID

E V

IEW

BA

TTE

RY

12

VO

LT

NE

GA

TIV

E G

RO

UN

DR

EM

OV

E C

OV

ER

FO

R A

CC

ES

S

TO R

AD

IATO

R F

ILL

CA

P

INTE

RN

AL

DIV

IDE

R P

AN

EL

SE

PA

RA

TES

FU

EL

TAN

K

VE

NTI

LATI

ON

DU

CT

FRO

M

THE

EN

GIN

E, A

LTE

RN

ATO

R

AN

D E

XH

AU

ST

SY

STE

M

RE

MO

VE

PA

NE

L TO

A

LLO

W T

AN

K V

EN

TS

TO T

ER

MIN

ATE

OU

TSID

E

OF

THE

GE

NE

RA

TOR

E

NC

LOS

UR

E (C

HE

CK

LO

CA

L A

ND

STA

TE

CO

DE

FO

R

AP

PLI

CA

BIL

ITY

)

TOP

VIE

W

Page 11: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

11 of 14

30 kW installation drawings

®

Prot

ecto

r™

D2.2L G22 Extended Tank (2 of 2)

43

21

43

1

AB

AB

888

[35.

0]

851

[33.

5]M

OU

NTI

NG

CE

NTE

RS

TYP

19[.7

]TY

P

438

[17.

2]29

1[1

1.5]

FUE

L TA

NK

HE

IGH

T

110

[4.3

]TY

P69

0[2

7.2]

TYP

1216

[47.

9]TY

P17

69[6

9.6]

TYP

2322

[91.

4]TY

P 2424

[95.

4]

717

[28.

2]

2089

[82.

2]TY

P

351

[13.

8]

227

[9.0

]

101

[4.0

]

282

[11.

1]266

[10.

5]TY

P

487

[19.

2]

620

[24.

4]TY

P

660

[26.

0]TY

P

169

[6.7

]

216

[8.5

]

314

[12.

3]

1314

[51.

7]TY

P

1386

[54.

6]TY

P

125

[4.9

]S

TUB

-UP

AR

EA12

5[4

.9]

STU

B-U

PA

RE

A

253

[10.

0]

62[2

.5]

38 [1.5

]

786

[30.

9]

2160

[85.

0]

51 [2.0

]

850

[33.

5]

FUE

L TA

NK

TOTA

L C

AP

AC

ITY

233

[61]

US

AB

LE C

AP

AC

ITY

215

[57]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.2L

G22

EX

TEN

DE

D T

AN

K

ISSU

E D

ATE:

10/2

017

SIZ

EC

AG

E N

OD

WG

NO

1000

0018

412

RE

V

BN

/A

CSC

ALE

0.07

5 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

2/2

REV

CW

INDC

HILL

VER

SION

C.1

NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

]D

IME

NS

ION

S: M

M [I

NC

H]

16.7

[0.6

6]

MO

UN

TIN

G H

OLE

S

(10

PLA

CE

S) S

EE

N

OTE

9

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

W

LEFT

SID

E V

IEW

OU

TER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

INN

ER

TA

NK

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

)

INN

ER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

FUE

L S

UP

PLY

OU

TER

TA

NK

LE

AK

DE

TEC

TOR

HIG

H A

ND

LO

W V

OLT

AG

E

STU

B-U

P A

RE

A

TOP

VIE

W

FUE

L FI

LL(2

" NP

T FE

MA

LE)

FUE

L LE

VE

LG

AU

GE

/SE

ND

ER

CU

STO

ME

R O

PTI

ON

(2" N

PT

FEM

ALE

)

FUE

L R

ETU

RN

Page 12: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

12 of 14

30 kW installation drawings

®

Prot

ecto

r™

D2.2L G22 132 Gal Tank (1 of 2)

43

21

43

1

AB

AB

1733

[68.

2]O

VE

RA

LLH

EIG

HT

888

[35.

0]O

VE

RA

LL W

IDTH

603

[23.

7]TY

P

197

[7.8

]TY

P24

24[9

5.4]

OV

ER

ALL

LE

NG

TH

1938

[76.

3]TY

P

897

[35.

3]D

OO

R W

IDTH

TYP

173

[6.8

]E

XH

AU

ST

OU

TLE

T

611

[24.

0]E

XH

AU

ST

OU

TLE

T

1029

[40.

5]C

EN

TER

OF

GR

AV

ITY

SE

RV

ICE

ITE

M2.

2LO

IL F

ILL

CA

PR

IGH

T S

IDE

OIL

DIP

STI

CK

RIG

HT

SID

EO

IL F

ILTE

RR

IGH

T S

IDE

OIL

DR

AIN

HO

SE

RIG

HT

SID

ER

AD

IATO

R D

RA

IN H

OS

ELE

FT S

IDE

CO

OLA

NT

RE

CO

VE

RY

BO

TTLE

LEFT

SID

ER

AD

IATO

R F

ILL

CA

P A

CC

ES

SR

OO

FA

IR C

LEA

NE

R E

LEM

EN

TR

IGH

T S

IDE

MU

FFLE

RFR

ON

T S

IDE

FAN

BE

LTE

ITH

ER

SID

EB

ATT

ER

YLE

FT S

IDE

WE

IGH

T D

ATA

WIT

H E

MP

TY B

AS

ETA

NK

(SE

E N

OTE

5)

GE

NE

RA

TOR

AS

SH

OW

N93

9 [2

070]

WIT

H W

OO

DE

N S

HIP

PIN

G S

KID

985

[217

2]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.2L

G22

13

2 G

AL

TAN

K

ISSU

E D

ATE:

01/2

018

SIZ

EC

AG

E N

OD

WG

NO

1000

0029

492

RE

V

BN

/A

ASC

ALE

0.04

5 W

T-K

GS

EE

AB

OV

ES

HE

ET

1 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

1/2

REV

AW

INDC

HILL

VER

SION

A.1

RA

DIA

TOR

/EX

HA

US

T D

ISC

HA

RG

E A

IR

AIR

INTA

KE

(BO

TH S

IDE

S)

RA

DIA

TOR

/EX

HA

US

T D

ISC

HA

RG

E A

IR(B

OTH

SID

ES

)

NO

TES

: 1.

MIN

IMU

M R

EC

OM

ME

ND

ED

CO

NC

RE

TE P

AD

SIZ

E: 1

194

(47"

) WID

E X

226

1 (8

9") L

ON

G.

RE

FER

EN

CE

INS

TALL

ATI

ON

GU

IDE

SU

PP

LIE

D W

ITH

UN

IT F

OR

CO

NC

RE

TE P

AD

GU

IDE

LIN

ES

2. A

LLO

W S

UFF

ICIE

NT

RO

OM

ON

ALL

SID

ES

OF

THE

GE

NE

RA

TOR

FO

R M

AIN

TEN

AN

CE

AN

D S

ER

VIC

ING

. TH

IS U

NIT

MU

ST

BE

INS

TALL

ED

IN A

CC

OR

DA

NC

E W

ITH

CU

RR

EN

T A

PP

LIC

AB

LE N

FPA

37

AN

D N

FPA

70

STA

ND

AR

DS

AS

WE

LL A

S A

NY

OTH

ER

FE

DE

RA

L, S

TATE

, AN

D L

OC

AL

CO

DE

S.

3. C

ON

TRO

L P

AN

EL

/ CIR

CU

IT B

RE

AK

ER

INFO

RM

ATI

ON

: -

SE

E S

PE

CIF

ICA

TIO

N S

HE

ET

OR

OW

NE

RS

MA

NU

AL

- A

CC

ES

SIB

LE T

HR

OU

GH

CU

STO

ME

R A

CC

ES

S A

SS

EM

BLY

DO

OR

ON

RE

AR

OF

G

EN

ER

ATO

R4.

RE

MO

VE

TH

E R

EA

R T

AN

K A

ND

RE

AR

EN

CLO

SU

RE

CO

VE

R P

AN

EL

TO A

CC

ES

S T

HE

STU

B-U

P A

RE

AS

AS

FO

LLO

WS

: -

HIG

H V

OLT

AG

E C

ON

NE

CTI

ON

INC

LUD

ING

AC

LO

AD

LE

AD

CO

ND

UIT

CO

NN

EC

TIO

N

NE

UTR

AL

CO

NN

EC

TIO

N, B

ATT

ER

Y C

HA

RG

ER

120

VO

LT A

C (0

.5 A

MP

MA

X) C

ON

NE

CTI

ON

. -

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S IN

CLU

DIN

G T

RA

NS

FER

SW

ITC

H C

ON

TRO

L W

IRE

S5.

CE

NTE

R O

F G

RA

VIT

Y A

ND

WE

IGH

T M

AY

CH

AN

GE

DU

E T

O U

NIT

OP

TIO

NS

.6.

EN

GIN

E S

ER

VIC

E C

ON

NE

CTI

ON

S

OIL

DR

AIN

: 3/8

" NP

T

EX

HA

US

T O

UTL

ET:

2" O

.D.

7. B

OTT

OM

OF

GE

NE

RA

TOR

SE

T M

US

T B

E E

NC

LOS

ED

TO

PR

EV

EN

T P

ES

T IN

TRU

SIO

N A

ND

AN

D R

EC

IRC

ULA

TIO

N O

F D

ISC

HA

RG

E A

IR A

ND

/OR

IMP

RO

PE

R C

OO

LIN

G A

IR F

LOW

.8.

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

LIF

TIN

G W

AR

NIN

GS

.9.

MO

UN

TIN

G B

OLT

S O

R S

TUD

S T

O C

ON

CR

ETE

PA

D S

HA

LL B

E 5

/8-1

1 G

RA

DE

5

(U

SE

STA

ND

AR

D S

AE

TO

RQ

UE

SP

EC

S)

RE

FER

EN

CE

OW

NE

RS

MA

NU

AL

FOR

P

ER

IOD

IC R

EP

LAC

EM

EN

T P

AR

T LI

STI

NG

S

WE

IGH

T: K

G [L

BS

]D

IME

NS

ION

S: M

M [I

NC

H]

RE

AR

EN

CLO

SU

RE

C

OV

ER

PA

NN

EL,

S

EE

NO

TE 4

CIR

CU

IT B

RE

AK

ER

S

EE

NO

TE 3

CU

STO

ME

R A

CC

ES

S

AS

SE

MB

LY, C

ON

TRO

L P

AN

EL

AC

CE

SS

, B

ATT

ER

Y C

HA

RG

ER

LO

CA

TED

WIT

HIN

S

EE

NO

TE 4

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

WLI

FTIN

G P

RO

VIS

ION

S (4

PLA

CE

S)

SE

E N

OTE

S 5

, 8 A

ND

CE

NTE

R

OF

GR

AV

ITY

DIM

EN

SIO

NS

VIS

E A

CTI

ON

LA

TCH

, ON

E P

ER

D

OO

R, O

NE

LIF

T-O

FF D

OO

R O

N

FRO

NT,

RIG

HT

AN

D L

EFT

SID

ES

LIFT

DO

OR

PR

OV

IDE

S A

CC

ES

S T

O: F

UE

L FI

LL, F

UE

L LE

VE

L G

AU

GE

, NO

RM

AL

VE

NT,

IN

NE

R T

AN

K E

ME

RG

EN

CY

VE

NT,

OU

TER

TA

NK

EM

ER

GE

NC

Y V

EN

T, O

PTI

ON

AL

90%

A

LAR

M A

SS

EM

BLY

, OP

TIO

NA

L 5

GA

LLO

N

SP

ILL

BO

X

RIG

HT

SID

E V

IEW

EX

HA

US

T M

UFF

LER

E

NC

LOS

ED

WIT

HIN

G

EN

ER

ATO

R E

NC

LOS

UR

E

OP

EN

PU

NC

HE

D

LOU

VE

RS

TY

PIC

AL

ON

B

OTH

SID

ES

OF

FUE

L TA

NK

VE

NTI

LATI

ON

D

UC

T TO

PR

OV

IDE

A

DE

QU

ATE

CR

OS

S-F

LOW

O

F A

IR V

EN

TILA

TIO

N

FUE

L TA

NK

V

EN

TILA

TIO

N D

UC

T

LEFT

SID

E V

IEW

BA

TTE

RY

12

VO

LT

NE

GA

TIV

E G

RO

UN

DR

EM

OV

E C

OV

ER

FO

R A

CC

ES

S

TO R

AD

IATO

R F

ILL

CA

P

INTE

RN

AL

DIV

IDE

R P

AN

EL

SE

PA

RA

TES

FU

EL

TAN

K

VE

NTI

LATI

ON

DU

CT

FRO

M

THE

EN

GIN

E, A

LTE

RN

ATO

R

AN

D E

XH

AU

ST

SY

STE

M

RE

MO

VE

PA

NE

L TO

A

LLO

W T

AN

K V

EN

TS

TO T

ER

MIN

ATE

OU

TSID

E

OF

THE

GE

NE

RA

TOR

E

NC

LOS

UR

E (C

HE

CK

LO

CA

L A

ND

STA

TE

CO

DE

FO

R

AP

PLI

CA

BIL

ITY

)

TOP

VIE

W

Page 13: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

13 of 14

30 kW installation drawings

®

Prot

ecto

r™

D2.2L G22 132 Gal Tank (2 of 2)

43

21

43

1

AB

AB

888

[35.

0]

851

[33.

5]M

OU

NTI

NG

CE

NTE

RS

TYP

19[.7

]TY

P

676

[26.

6]

529

[20.

8]FU

EL

TAN

KH

EIG

HT

110

[4.3

]TY

P69

0[2

7.2]

TYP

1216

[47.

9]TY

P17

69[6

9.6]

TYP

2322

[91.

4]TY

P

2424

[95.

4]

715

[28.

1]

2089

[82.

2]TY

P

377

[14.

8]

247

[9.7

]11

7[4

.6]

280

[11.

0] 264

[10.

4]TY

P

485

[19.

1]

618

[24.

3]TY

P

658

[25.

9]TY

P

167

[6.6

]

247

[9.7

]

314

[12.

4]

1307

[51.

5]TY

P

1418

[55.

8]TY

P

125

[4.9

]S

TUB

-UP

AR

EA12

5[4

.9]

STU

B-U

PA

RE

A

253

[10.

0]

62[2

.5]

38 [1.5

]

786

[30.

9]

2160

[85.

0]

51 [2.0

]

850

[33.

5]

FUE

L TA

NK

TOTA

L C

AP

AC

ITY

524

[138

.5]

US

AB

LE C

AP

AC

ITY

500

[132

]

TIT

LE

INS

TALL

PR

OTE

CTO

R D

2.2L

G22

13

2 G

AL

TAN

K

ISSU

E D

ATE:

01/2

018

SIZ

EC

AG

E N

OD

WG

NO

1000

0029

492

RE

V

BN

/A

ASC

ALE

0.06

5 W

T-K

GS

EE

AB

OV

ES

HE

ET

2 of

2

GE

NE

RA

C P

OW

ER

SY

STE

MS

OW

NS

TH

E C

OP

YR

IGH

T O

F TH

IS D

RA

WIN

GW

HIC

H IS

SU

PP

LIE

D IN

CO

NFI

DE

NC

E A

ND

MU

ST

NO

T B

E U

SE

D F

OR

AN

Y P

UR

PO

SE

OTH

ER

TH

AN

FO

R W

HIC

H IT

IS S

UP

PLI

ED

WIT

HO

UT

THE

EX

PR

ES

S W

RIT

TEN

CO

NS

EN

T O

F G

EN

ER

AC

PO

WE

R S

YS

TEM

S.

c G

EN

ER

AC

PO

WE

R S

YS

TEM

S 2

013

ELEC

TRO

NIC

ALLY

APP

RO

VED

INSI

DE

WIN

DC

HIL

L

DR

AWIN

G C

REA

TED

FR

OM

PR

O/E

NG

INEE

R3D

FIL

E. E

CO

MO

DIF

ICAT

ION

TO

BE

APPL

IED

TO

SO

LID

MO

DEL

ON

LY.

SH

2/2

REV

AW

INDC

HILL

VER

SION

A.1

NO

TE: S

TUB

-UP

AR

EA

FO

R H

IGH

A

ND

LO

W V

OLT

AG

E C

ON

NE

CTI

ON

S,

CIR

CU

IT B

RE

AK

ER

, NE

UTR

AL

AN

D

CU

STO

ME

R C

ON

NE

CTI

ON

OP

EN

ING

.

CA

PA

CIT

Y: L

ITE

R [G

ALL

ON

]D

IME

NS

ION

S: M

M [I

NC

H]

16.7

[0.6

6]

MO

UN

TIN

G H

OLE

S

(10

PLA

CE

S) S

EE

N

OTE

9

RE

MO

VA

BLE

S

TUB

-UP

CO

VE

RS

EE

NO

TE 4

RE

AR

VIE

W

LEFT

SID

E V

IEW

OU

TER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

INN

ER

TA

NK

NO

RM

AL

VE

NT

(2" N

PT

FEM

ALE

)

INN

ER

TA

NK

EM

ER

GE

NC

Y V

EN

T(2

" NP

T FE

MA

LE)

FUE

L S

UP

PLY

OU

TER

TA

NK

LE

AK

DE

TEC

TOR

HIG

H A

ND

LO

W V

OLT

AG

E

STU

B-U

P A

RE

A

TOP

VIE

W

FUE

L FI

LL(2

" NP

T FE

MA

LE)

FUE

L LE

VE

LG

AU

GE

/SE

ND

ER

CU

STO

ME

R O

PTI

ON

(2" N

PT

FEM

ALE

)

FUE

L R

ETU

RN

Page 14: Protector™ Series Diesel Generator Set · Model RD020 - 20 kW 60 Hz Model RD030 - 30 kW 60 Hz Protector ...

14 of 14

Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com

©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. 10000023912 rev B (02/21/18)

®

®

15 • 20 • 30 kW available accessories

Prot

ecto

r™

Model # Product Description

G006463-4 Mobile Link™

Generac's Mobile Link allows you to check the status of your generator from anywhere that you haveaccess to an Internet connection from a PC or with any smart device. You will even be notified whena change in the generator’s status occurs via e-mail or text message. Note: Harness Adapter Kitrequired. Available in the U.S. only.

G006478-0 Harness Adapter Kit The Harness Adapter Kit is required to make liquid-cooled units compatible with Mobile Link™.

G006502-0 Spill BoxThe 5-gallon spill box screws into the existing fuel fill port of the base tank. It captures and containsfuel if over fueling or spilling occurs during the fill process.

G006504-0 90% Fuel Level AlarmThe 90% fuel level alarm alerts the fuel fill operator when the tank reaches a 90% fill level bysounding an audible alarm and triggering an LED warning light.

G006505-0 - 15 & 20 kWG006506-0 - 30 kW

Tank RisersTank risers are required in some municipalities to help avoid potential base tank corrosion caused bymounting on rough surfaces.

G006507-0 Fuel Fill Drop Tube

A powder coat painted, steel fuel fill drop tube is required in some municipalities to prevent sparkingdue to static electricity buildup, which can be caused by the fuel dropping into the tank from the fillarea. Using a drop tube also results in submerged filling, which increases the fuel delivery flow rateand reduces vapors, foam and potential tank evaporation.

G007660-0 - 15 & 20 kWG007661-0 - 30 kW

Stainless Steel Fuel LinesSome municipalities require the use of stainless steel fuel lines instead of the standard hosesprovided with the diesel generator products. These stainless steel lines are fire resistant for additionalsafety.

G006510-0 E-Stop E-stop allows for immediate fuel shutoff and generator shutdown in the event of an emergency.

G006511-0 Spill Box Drainback KitThe spill box drainback kit allows fuel that was captured in the 5-gallon spill box to be drained directlyback into the fuel tank to avoid vapors.

G006588-1 Vent Extension Support KitThe vent extension support kit consists of two aluminum plates with the appropriate pipe cutouts tosecure the vent extension pipes coming through the top of the generator enclosure. It helps tominimize stress on the NPT fittings integrated on the tank and also helps protect against pests.

G006512-0 Lockable Fuel CapThe cast iron, lockable fuel cap provides the ability to lock the fuel system to prevent unwanted fueltampering or fuel siphoning.

G007640-0 - 15 & 20 kWG007641-0 - 30 kW

Maintenance KitsThe Protector Maintenance Kits offer all the hardware necessary to perform complete maintenanceon Generac Protector generators.

G007650-0 - 15 & 20 kWG007651-0 30 kW

Cold Weather KitsRecommended for generators installed in regions where the temperature regularly falls below 32 °F(0 °C). The Cold Weather Kits consist of a block heater with all necessary mounting hardware and abattery warmer with a thermostat built into the battery wrap.

G005703-0 Paint KitIf the generator enclosure is scratched or damaged, it is important to touch up the paint to protectfrom future corrosion. The paint kit includes the necessary paint to properly maintain or touch up agenerator enclosure

G006664-0 Local Wireless RemoteCompletely wireless and battery powered, Generac's wireless remote monitor provides you withinstant status information without ever leaving the house.

G006665-0Wireless Remote Extension Harness

Recommended for use with the Wireless Remote on units up to 60 kW, required for use on units 70kW or greater.

G006873-0Smart Management Module(50 Amps)

Manage large loads by utilizing up to 8 individual Smart Management modules. These devices areinstalled directly in line with existing appliance wiring for easy installation.