Protective Gloves: Permeation testing Reinhard Oppl John Hansen Eurofins Product Testing A/S
description
Transcript of Protective Gloves: Permeation testing Reinhard Oppl John Hansen Eurofins Product Testing A/S
October 20111
www.eurofins.com/glove-testing
Protective Gloves:
Permeation testing
Reinhard Oppl
John Hansen
Eurofins Product Testing A/SDenmark, Germany, France, USA, China, …
www.eurofins.com/glove-testing
October 20112
www.eurofins.com/glove-testing
Eurofins Product Testing – Locations
Galten, Denmarknear Arhus
Eurofins Product Testing A/S
Other business areas: Tests of food, feed, pharmaceuticals, genetics, environment
Manchester (UK)
Galten (DK)
Paris (FR)Torino (IT)
Hamburg (D)
Shanghai (CN)
Bangkok (TH)
Hong Kong (HK)
Shenzhen (CN)
Des Moines (USA)
Reichenwalde (D)
Bangalore (IND)
Bratislava (SK)
Aix (FR)
Barneveld (NL)
October 20113
www.eurofins.com/glove-testing
Test: Exposure of outer surface
Tightness against gases and liquids
(Penetration through seams, cracks and holes) EN 374-2, ASTM F903; visual evaluation (droplets, bubbles)
Infiltration on molecular level (Permeation) EN 374-3, ASTM F739, ISO 6529; Collection medium / analysis
Resistance (Degradation) ASTM D471-98, or similar to ISO 1817
Change of physical properties (e.g. tactile strength)
Ingredients test: Skin tolerance / allergies EN 455-3, latex proteins
EN 420, Chrome VI (leather gloves)
Protective gloves – chemicals
October 20114
www.eurofins.com/glove-testing
Infiltration on molecular level (Permeation)
Procedure Absorption in outer layers
Diffusion; possibly through several layers
Release from inner surface
Parameter: Breakthrough time and permeation rate
Experience Small molecules permeate faster than larger ones
Solvents may carry with them other substances that else may break
through much later
Chemical similarity of membrane and chemical increases permeation
Larger thickness slows down breakthrough; thickness varies within a
glove; take sample from palm or from back?
Protective gloves – chemicals
October 20115
www.eurofins.com/glove-testing
Nitrile does not equal Nitrile Latex, Nitrile, Neoprene: Huge differences in composition;
Nitrile glove can be 100% nitrile latex,
or it can be mainly natural latex with thin outer layer of nitrile latex
Mention a real product in Safety Data Sheet?
Conditions of use and of test Temperature (23 °C / 27 °C / 33°C) (huge effect)
Stretching (when moving fingers) (only small effect)
Duration of use and of test (splash protection / 8 hours / re-use next days)
Protective gloves – chemicals
October 20116
www.eurofins.com/glove-testing
Analysis Continuous / discontinuous
Direct monitoring (FID, UV, pH, conductivity, …) or enrichment by
sampling
Collection medium: Air / water / solids
Not volatile, not soluble in water :
Collection disc is pressed tightly to inner side;
then desorption by solvent and GC or HPLC analysis
Protective gloves – chemicals
October 20117
www.eurofins.com/glove-testing
www.eurofins.com/glove-testing
Best
MAPA
ISO 6529
Protective gloves – chemicals
October 20118
www.eurofins.com/glove-testing
Protective Gloves – Permeation
www.eurofins.com/glove-testing
October 20119
www.eurofins.com/glove-testing
Permeation testing since 1988
Test with adsorption discs: 1st laboratory in Europe firstly developed for epoxy coatings
Projects Improved Method for Testing of Protective Gloves
German Work Insurance and Prevention Services, 1999
Testing method for protective gloves for PAH at renovation work
German Federal Institute for Occupational Safety and Health, 2003
Risk assessment for occupational dermal exposure to chemicals
EU Commission, coordinated by TNO, 2004
Permeation testing - Eurofins
October 201110
www.eurofins.com/glove-testing
Which chemical product or mixture? If possible – selection of representative products
Physical state – gas, liquid, viscous, solid, granulate?
Selection of gloves for testing? Safety versus wearing comfort and costs
Which manufacturer? Who buys the samples?
Questions on testing Duration / frequency of testing
Testing temperature (our recommendation: at 33 °C as "worst-case")
Selection of collection medium and detection / analysis
Calibration with product, or with clean substances?
Ideas of customer on extraction / analysis?
Questions before any test