1 © ABB Group March 31, 2010 | Slide 1 Protection Relay for Transmission IED 670 Series 王中平 王中平 王中平 王中平, 高雄電機技師公會 高雄電機技師公會 高雄電機技師公會 高雄電機技師公會, 2010/03/31 Image courtesy of the Taiwan Tourism Bureau © ABB Group March 31, 2010 | Slide 2 The Relion ® product family From intercontinental transmission grids to secondary distribution kiosks 670 series - optimized for transmission applications 630 series - optimized for advanced distribution applications 610 series - for dedicated distribution applications 650 series – your best choice for sub-transmission applications 615 series - standard configurations for distribution applications 60_ series - for secondary distribution applications

Transcript of Protection Relay for Transmission 20100331

Page 1: Protection Relay for Transmission 20100331

1

© ABB Group March 31, 2010 | Slide 1

Protection Relay for TransmissionIED 670 Series

王中平王中平王中平王中平,,,, 高雄電機技師公會高雄電機技師公會高雄電機技師公會高雄電機技師公會,,,, 2010/03/31

Image courtesy of the Taiwan Tourism Bureau

© ABB Group March 31, 2010 | Slide 2

The Relion® product familyFrom intercontinental transmission grids to secondary distribution kiosks

� 670 series - optimized for

transmission applications

� 630 series - optimized for

advanced distribution

applications

� 610 series - for dedicated

distribution applications

� 650 series – your best

choice for sub-transmission

applications

� 615 series - standard

configurations for

distribution applications

� 60_ series - for secondary

distribution applications

Page 2: Protection Relay for Transmission 20100331

2

© ABB Group March 31, 2010 | Slide 3

� Same

� mechanical 19” design

� internal CAN bus & I/O cards

� Principle algorithms & logic

� Extended modular hardware

� Max 24 Analogue Inputs

� Max 14 I/O boards (i.e..224BI / Max 4 BOM = 98BO)

� More powerful CPU & memory capacity

� 600 MHz, 256 Mb DRAM + 64 Mb Flash

� Extended functional library (IEC 61850 nodes)

� Disturbance Recorder (100 x 3.4 s; 40 A + 96B)

� Extended communication facilities

� Multiple SA protocols

� Multiple differential communication channels

� Graphical HMI

� Engineering tool; PCM 600

� Signal matrix

� IEC 61850 configuration

IED670 670 vs 500 series; Evolution not Revolution

© ABB Group March 31, 2010 | Slide 4

IED670 Robust design for HMI, communication, AI and I/O

Page 3: Protection Relay for Transmission 20100331

3

© ABB Group March 31, 2010 | Slide 5

IED670 Select your perfect hardware

© ABB Group March 31, 2010 | Slide 6

BIM

(max 11/14st)

16 binary inputs

BOM

(max 4st)

24 binary outputs

IOM

(max 6st)6 Transducer inputs,

setting range + 20 mA

MIM

(max 4st)

12 binary outputs

and 8 binary inputs

� Up to 24 analog inputs per IED permit integration of main and back-up protection in one IED

and/or additional objects

IED670 Available I/O-modules 1/1 19” case

Page 4: Protection Relay for Transmission 20100331

4

© ABB Group March 31, 2010 | Slide 7

� Transformer Input Module TRM 6I + 6U, 9I+3U or 12I

� One or two - TRM1 & TRM2 for 12 or 24 analogue CT or VT inputs

� Analog Digital Conversion module ADM1 and ADM2 for TRM inputs

� Central Processing Unit NUM

� GPS time synchronization module GSM (option)

� Time synchronization via binary signal and communication ports IRIG-B

� Binary Input / Output modules BIM, SOM, BOM, IOM, MIM

� Power supply module PSM

IED670 670 Series Hardware Platform

© ABB Group March 31, 2010 | Slide 8

ABB IED 670

A/D

Module

~~

Analogue

Module

~~

A/D6 I

6 U

3

3

3

3

ConversionInput

Logics

Comm-uni-

cation

Main

ModuleProcessing

GPS

ModuleSynch

Binary

ModuleI/O

I/O

Binary

Module

I/O

CAN1Mbit/s

TRM AD1 NUM GSM BIM

PCU

OEMLDCM

Binary

ModuleI/O

BIM BIM MIM PSM

I/O I/O I/O

BOMBOM

Binary

Module

I/OBinary

Module

I/OPower

Module

SupplymA

Module

Input

mAI/O

IED670 670 Series Hardware Platform

Page 5: Protection Relay for Transmission 20100331

5

© ABB Group March 31, 2010 | Slide 9

Transformer module (TRM 12) 1 A 5A 110/220 V

6I and 6U 6 6

6I and 6U 6 6

9I + 3U 9 3

9I + 3U 9 3

9I + 3U 5 4 3

12I 12

12I 12

6I

5I + 5U

6

5 5

IED670 Standardized Transformer Modules

© ABB Group March 31, 2010 | Slide 10

� GPS time synch module (GSM)

� IRIG-B time synch

� Up to 4 Protection Communication Modules for multi terminal line differential (LDCM)

� Optical Communication modules

� OEM IEC 61850-8-1 Ethernet

� OEM IEC 61850-9-2 Ethernet (restricted)

� SLM LON(1); SPA or IEC103

� RS485 DNP 3.0 module

� Static binary output module (SOM)

1/1 19” rack, 6U high

½ 19” rack, 6U high

IED670 Available I/O-modules 1/1 19” case

Page 6: Protection Relay for Transmission 20100331

6

© ABB Group March 31, 2010 | Slide 11

� IED 670s are designed to communicate with substation automation systems

� IEC 61850-8-1

� verified by independent test institution

� IEC 60870-5-103

� LON

� SPA

� DNP 3.0

� TCP/IP communication to the PCM 600 tool

� IEC 61850-9-2 for process bus

� ANSI C37.94 for teleprotection

PC Ethernet connection

IEC 60870-5-103

or SPA

IEC 61850 8-1

or LON

192 binary

signals remote

communication

4 x 4 analog channels

4 x 8 binary signals

remote communication

IED670 Communication

© ABB Group March 31, 2010 | Slide 12

GOOSE

� Peer to peer communication

� An IED sends information by multicasting

� Only IEDs which are defined to listen (subscribers) receive this message

GOOSE = Generic Object Oriented System-wide Events

Data to be sent to other IEDs are

defined in the engineering tool

ProtectionControlProtectionControl Control &

Protection

IED670 ALL IED670 include GOOSE

Page 7: Protection Relay for Transmission 20100331

7

© ABB Group March 31, 2010 | Slide 13

IED670 Powerful Information Management

� Protection and Control IED Manager for the 600 series

� PCM600

� PCM 600 consists of following tools:

� Application Configuration(CAP531)

� Signal Matrix (SMT)

Configuration of:

I/O cards,

Analog Input Cards

GOOSE

64 kbit communication

� Parameter Setting (PST)

� Disturbance Handling

� Graphic Display Editor (SLD Editor)

� Time scheduler

� Signal Monitoring

� Event Viewer

� User Management

© ABB Group March 31, 2010 | Slide 14

IED670 One Common Tool

Page 8: Protection Relay for Transmission 20100331

8

© ABB Group March 31, 2010 | Slide 15

IED670 PCM600 Parameter Setting

© ABB Group March 31, 2010 | Slide 16

� All parameters set in primary quantities within

the pre-defined setting ranges

� Clear overview of parameter settings

uploaded from an IED and settings entered in

PCM 600

� Versatile filtering functions:

� Basic and advanced parameters

� Visible and hidden parameters

� Changed parameters

� Parameter value in IED differs from

the parameter value in PCM 600 and

invalid parameters

IED670 Full Control Over Parameter Settings

Page 9: Protection Relay for Transmission 20100331

9

© ABB Group March 31, 2010 | Slide 17

� Easy to instantiate the power

system object into the display page

and assign it to its switching

function

� Easy to include on-line

measurement in the IED HMI

� Easy to set node attributes like

name, name position and sort index

� Extensive IEC and ANSI symbol

library

IED670 PCM600 Graphical Configuration of IED HMI

© ABB Group March 31, 2010 | Slide 18

� Signal monitoring for on-line information about the measured quantities and status of binary input and output signals

� All signals can be monitored in a signal list

� A report can be generated, printed and exported to Excel

� Event viewer for viewing process events and internal system events on-line

IED670 Monitoring

Page 10: Protection Relay for Transmission 20100331

10

© ABB Group March 31, 2010 | Slide 19

IED670 Signal Matrix Tool (SMT)

© ABB Group March 31, 2010 | Slide 20

IED670 Signal Matrix Tool (SMT)

Page 11: Protection Relay for Transmission 20100331

11

© ABB Group March 31, 2010 | Slide 21

HARDWARE: Binary Input Card

IED670 SMT: Virtual and Real Binary Inputs

© ABB Group March 31, 2010 | Slide 22

IED670 The role of SMT for Binary Outputs

Page 12: Protection Relay for Transmission 20100331

12

© ABB Group March 31, 2010 | Slide 23

IED670 Analog Input Configuration

© ABB Group March 31, 2010 | Slide 24

� 40 analog channels

� flexible analog configuration

� voltages and/or currents (30 channels via AIM, LDCM or Σ-block)

� derived analog signals (10 channels)

� setting possibilities:

� be recorded or not

� trig disturbance recording

� 96 binary channels

� any internal or external (via BIM) binary signal

� these 96 signals are logged into IED internal Event List

� setting possibilities:

� be recorded or not

� trig disturbance recording and trigger mode

� be included in Indications

� activate local HMI LED

IED670 Disturbance Recorder – Inputs

Page 13: Protection Relay for Transmission 20100331

13

© ABB Group March 31, 2010 | Slide 25

TOTAL RECORDING

Visualisation of the full disturbance: analog and binary signals.

IED670 PCM 600 - Disturbance Report Tool

© ABB Group March 31, 2010 | Slide 26

� The event buffer can store and show on display

up to 1000 events on a FIFO principle

� The events are time tagged with a resolution of

1 ms

� The user can choose in having the last event on

top or the last event on bottom

� Events can be defined as a part of the

Disturbance Report

� Upload event list to PC

� Event list sorting facility

Ev e n

No r t Co n nh e c o n2 0 0 4 - 1 2 1- 7 0 8 : 3 7

t s L i s t

51 2 : 1 7 : 4 . 7 1 151 2 : 1 7 : 4 . 1 1 TR I P - T 1RL

5 3 . 6 1 15 . 1 1 TR I P - T PR I

. 6 1 1. 1 1 ZM3 - STL 1

. 6 1 1. 1 1 CB1 - CLOSE

51 2 : 1 6 : 8 . 7 1 151 2 : 1 : . 1 1 ZCOM- CS

5 7 . 6 1 15 . 1 1 TR I P - T PR I

. 6 1 1. 1 1 TOC1 - T PR I

52 0 0 4 - 1 2 1-

51 2 : 1 7 : 6 . 7 1 151 2 : 1 7 : . 1 1

5 5 . 6 1 15 . 1 1

. 6 1 1. 1 1

. 6 1 1. 1 1

51 2 : 1 6 : 8 . 7 1 151 2 : 1 : . 1 1

5 7 . 6 1 15 . 1 1

. 6 1 1. 1 1

42 0 0 4 - 1 2 1-

51 2 : 1 7 : 6 . 7 1 151 2 : 1 7 : . 1 1

5 5 . 6 1 15 . 1 1

. 6 1 1. 1 1

. 6 1 1. 1 1

51 2 : 1 6 : 8 . 7 1 151 2 : 1 : . 1 1

5 7 . 6 1 15 . 1 1

. 6 1 1. 1 1

32 0 0 4 - 1 2 1-

51 2 : 1 7 : 6 . 7 1 151 2 : 1 7 : . 1 1

5 5 . 6 1 15 . 1 1

. 6 1 1. 1 1

. 6 1 1. 1 1

22 0 0 4 - 1 2 1-

o n

o n

o n

o n

o f f

o n

o n

t i

450

210

660

970

690

210

110

TR I P - T 1RL

TR I P - T PR I

ZM3 - STL 1

CB1 - CLOSE

ZCOM- CS

TR I P - T PR I

TOC1 - T PR I

o n

o n

o n

o n

o f f

o n

o n

450

210

660

970

690

210

110

TR I P - T 1RL

TR I P - T PR I

ZM3 - STL 1

CB1 - CLOSE

ZCOM- CS

TR I P - T PR I

TOC1 - T PR I

o n

o n

o n

o n

o f f

o n

o n

450

210

660

970

690

210

110

TR I P - T 1RL

TR I P - T PR I

ZM3 - STL 1

CB1 - CLOSE

o n

o n

o n

o n

450

210

660

970

\ E v e n t

IED670 Event List Handling

Page 14: Protection Relay for Transmission 20100331

14

© ABB Group March 31, 2010 | Slide 27

IED670 IED670 Operation introduction

© ABB Group March 31, 2010 | Slide 28

Status indication

� GreenSteady: In serviceFlashing: Internal failureDark : No power supply

� Yellow:Steady: Disturbance recorder triggeredFlashing: IED in test mode

� Red:Steady: Trip command issued

Flashing: IED blocked

Measurements

� Single line diagram presents measurements

� Selected measurements

� Selected calculated values

IED670 Fast Access to Information

Page 15: Protection Relay for Transmission 20100331

15

© ABB Group March 31, 2010 | Slide 29

� Service Value Measurement (I, U, P, Q, S, f)

� Configurable logic and event counter

� Signal and Tripping matrix

� Remote communication (requires LDCM)

� Event list (1000 signals)

� Disturbance recorder for 40 analogue & 96 digital channels

� 100 disturbances

� Trip value & internal signals report

� Supervision of I, U and mA inputs

� Real time clock with external synchronization

� 1 ms time tagging resolution

� 6 setting groups

� >< U, I, I1 , I2 , 3I0 , f, Z configurable functions

� Self supervision & diagnostics

IED670 Main Basic Functions in IED 670

© ABB Group March 31, 2010 | Slide 30

� Five Zone full scheme distance protection

� Five terminal line differential protection

� Six input transformer differential protection

� Generator differantial/block differential

� High impedance and restricted EF differential

� Ultra High Speed bus differential protection

� Phase segregated directional comparison

� Adaptive Breaker Failure Protection

� Four step Dir/Undir overcurrent protection

� Four step Dir/Undir earthfault protection

� Over Excitation & Over Load Protection

� Multi purpose protection (E.g. Generators, Mho)

� Multi bay & Multi breaker Control, AR & SC

� Multi input measurement (24 AI)

� High accuracy fault locator

IED670 Main Application Functions in IED670

Page 16: Protection Relay for Transmission 20100331

16

© ABB Group March 31, 2010 | Slide 31

IED670 – Application areas

REC670

REL670

RET670

RED670

� Busbar protection IED for

� Autotransformers

� Shunt Reactors

� Shunt Capacitors

REB670� Generator protection IED for

� small to medium sized generators

REG670

IED670

© ABB Group March 31, 2010 | Slide 32

IED670 ABB Substation Automation Web Site

Page 17: Protection Relay for Transmission 20100331

17

© ABB Group March 31, 2010 | Slide 33

IED670 ABB Substation Automation Web Site

�Our Web Site

�www.abb.com/substationautomation

�www.abb.com/relion

�www.abb.com.tw

�聯絡人:

�王中平 0935-080-880

�李聖彬 0922-882-906

�E-mail: [email protected]