Protection Circuit Module - LiTechPower.com... E-mail: [email protected] Tele: +86 769 8203 3052...
Transcript of Protection Circuit Module - LiTechPower.com... E-mail: [email protected] Tele: +86 769 8203 3052...
For 37V 10S Li-ion/Li-Polymer Battery Packs
www.LiTechPower.com E-mail: [email protected]
Tele: +86 769 8203 3052 | Fax: +86 769 82033050
Factory Dongguan: 4F, Bldg B, RuiXin HengYe Industrial Park, TaiXing Rd # 18A, ShiGu District, TangXia Town, DongGuan, China
Factory Shenzhen: 3F, Bldg 3, Fulian Industrial Park, Heping Industrial area, Jianhui Rd, Longhua, ShenZhen, China
LiTech Power Co., Ltd
LiTech Power Co.,Ltd
www.LiTechPower.com | [email protected]
Copyright © LiTech Power Co.,Ltd. All Rights Reserved.
www.LiTechPower.com E-mail: [email protected]
Specifications and data are subject to change without notice. Contact LiTech Power for latest information.
Protection Circuit ModulePCM / BMS / PCB
L120mm*W80mm*H20mm
Contents
Maximal continuous discharging current
HCX-D596LI10S90A-13/AAH
Charging voltage
Maximal continuous charging current
Current consumption
Over charge detection voltage
Over charge detection delay time
Over charge release voltage
Over discharge detection voltage
Over discharge detection delay time
Over discharge release voltage
Over current detection current
Detection delay time
Release condition
Over current detection current
Short circuit detection current
Detection delay time
Release condition
Balance voltage for single cell
Balance current for single cell
Inner resistance
Operating temperature range
Storage temperature range
Criteria(Adjustable)
160A±20A
10S-90A working current
42V
50A
90A
≤50μA
4.25V±0.025V
700mS-1300mS
4.10V±0.05V
3.00V±0.07V
80mS-170mS
3.0V±0.1V
174mS-406mS
Cut load, automatically recover
260A±30A
>=690A
150uS-500uS
Cut load, automatically recover
4.20V±0.025V
126mA±15mA
≤20mΩ
0 ~ +85°C
0 ~ +85°C
Model
Overcharge Protection
Current
Voltage
Over Current Protection(1st Protection)
Short Circuit Protection
Balance
Resistance
Temperature
Size (L*W*H)
Over Discharge Protection
Item
1
2
3
4
6
8
9
10
11
12
5
Over Current Protection(2nd Protection)7 Detection delay time 10mS-25mS
Release condition Cut load, automatically recover
Note: Characteristics subject to change without notice
www.LiTechPower.com E-mail: [email protected]
Tele: +86 769 8203 3052 | Fax: +86 769 82033050
Factory Dongguan: 4F, Bldg B, RuiXin HengYe Industrial Park, TaiXing Rd # 18A, ShiGu District, TangXia Town, DongGuan, China
Factory Shenzhen: 3F, Bldg 3, Fulian Industrial Park, Heping Industrial area, Jianhui Rd, Longhua, ShenZhen, China
LiTech Power Co., Ltd
LiTech Power Co.,Ltd
www.LiTechPower.com | [email protected]
Copyright © LiTech Power Co.,Ltd. All Rights Reserved.
www.LiTechPower.com E-mail: [email protected]
Specifications and data are subject to change without notice. Contact LiTech Power for latest information.
Note: Characteristics subject to change without notice
Connection Diagram:
PCB Layout:
* Note: The switch is not included, BMS has the E-Switch function. When the switch is off, the output
will be shut down completely!
Charge, Discharge at different Port
P+=B+=Charge+/Discharge+
Ch-=Charge-
P-=Discharge-
Remarks:
* BMS with E-Switch//ON-OFF Switch (optional)
During charging and discharging,
The Switch should be on(connected)