PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable...

25
PROSTHESIS MANUAL

Transcript of PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable...

Page 1: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

PROSTHESIS MANUAL

Page 2: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information
Page 3: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

INDEX

PRESENTATION

INTRODUCTION

CEMENTED PROSTHESIS

CEMENT-SCREWED PROSTHESIS

REMOVABLE PROSTHESISOVERDENTURES

LABELING CODE SYMBOLOGY

INSTRUCTIONS FOR USE

MRI SAFETY INFORMATION

SURGICAL INSTRUMENTS

GUARANTEE PROGRAM

CHART OF MICRODENT EKTOS ABUTMENTS IMPRESSION TAKING

PROVISIONAL ABUTMENT

Pag. 05

Pag. 06

Pag. 06

Pag. 12

Pag. 13

Pag. 14

Pag. 15

Pag. 15

Pag. 15

Pag. 15

Pag. 16

Pag. 10

Pag. 08

Pag. 09

Microdent Ektos Cover screw

Microdent Ektos Healing abutment

Microdent Ektos Conical (straight) abutment without flap

Microdent Ektos Conical (straight) abutment with flap

Microdent Ektos multifunction (straight) abutment

Microdent Ektos Immediate loading Conical (straight) abutment

Microdent Ektos Mini Capitel abutment

Microdent Ektos Osscilia retention abutment

Microdent Ektos Retention screw

Microdent Ektos Angled abutment

Microdent Ektos Angled Mini Capitel abutment

PROSTHESIS MANUAL

MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT

SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL

IMPRESSION TAKING: NECESSARY MATERIAL

IMPRESSION TAKING: NECESSARY MATERIAL

ABUTMENTS

MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL

PROSTHESIS: NECESSARY MATERIAL

PROSTHESIS: NECESSARY MATERIAL

IMPLANTS

MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP

MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP

MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT

MICRODENT EKTOS ANGLED ABUTMENT

MICRODENT EKTOS MINI CAPITEL ABUTMENT

MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT

CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION ABUTMENT

MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT

WARNINGS

OPEN TRAY IMPRESSION TAKING

CLOSED TRAY IMPRESSION TAKING

Page 4: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information
Page 5: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

PRESENTATION

Implant Microdent System S.L. is a company that, from its creation in 1983, has specialized in developing, manufacturing and marketing components for odontological treatments, and, specially, oral implantology.

Always striving for customer satisfaction, Microdent offers all the guarantee, both of quality and service, backed up by its long and ascending professional history in the field of oral implantology.

The periodical offer of formation courses for professionals of the implantology field and the existence of a collaboration and assessment team allows Microdent to have products that verify the most strict quality parameters stablished, as well as to satisfy the needs of its clients.

Microdent has modern facilities equipped with the most cutting-edge technology, thus making Microdent into one of the pioneer companies in the research and manufacture of solutions for oral implantology. The patents obtained by Microdent products demonstrate the continued dedication of the company to the research work.

MICRODENT EKTOS PROSTHESIS MANUAL 5

Page 6: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

INTRODUCTION

PROSTHESIS MANUALThis manual informs dental practitioners and prosthetists of the different Microdent Implant System abutments available to make a dental prosthesis.

This prosthetic manual suggests which Microdent Ektos abutment should be used depending on the situation and/or requirements of the patient.

The use of the strict protocols described in this manual guarantees the efficacy of the Microdent products.

Microdent Ektos With internal hexagonal connection

WARNINGS

MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT

• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. • The multifunction abutment is characterized by its multiple functionality: implant holder, transfer and provisional abutment.• The multifunction abutment is supplied with the implant and cover screw in their own packaging in a sterile state.• The multifunction abutment is connected to the implant through the employment of a prosthetic screw, which is also presented in a sterile state.• The upper part of the abutment has a hexagonal socket to accomodate a tool for:- Implant and abutment extraction from the container.- Implant transport from the container to the insertion point.

MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP

• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.

MICRODENT EKTOS PROSTHESIS MANUAL6

Page 7: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP

• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment.• While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.

MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT

• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.

MICRODENT EKTOS ANGLED ABUTMENT

• A retention screw is provided in the container with the abutment.• Do not to exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cannot be modified.• Angled abutments are not recommended for the posterior region of the mouth.

MICRODENT EKTOS MINI CAPITEL ABUTMENT

• Use the UTSNLEC / UTSNLEC51 keys to screw the abutment and the implant together.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.

MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT

• The UTSNATR18 retention screw and the PACN carrier are provided in the container with the angled Mini Capitel abutment.• Use the PACN carrier to fix angled Mini Capitel abutment to its desired position.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.

MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT

• The use of the hex. 1.20 screwdriver is required to join the product and the implant together.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment.• Do not exceed a disparallelism of 17º between implants.• The exchange of retainers is facilitated through the use of the MC220PB screwdriver.• The retainers are identified by color. The different colors denote different retentive strengths. - Black retainer = soft retention strength 2Kg. For use in laboratory trials. - White retainer = middle retention strength 3Kg. To keep stable for a long period of time. - Red retainer = strong retention strength 4Kg. Only to be used in special cases where an extreme

fixation is required.

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

7

Page 8: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

IMPRESSION TAKING

CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION ABUTMENT

A multifunction abutment can be used for taking impressions with a closed tray.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth.Cast the model with type IV clay (ISO 6873) and use silicone if needed.

Necessary material

Necessary material

Ektos

HEX. MULTIFUNCTION ABUTMENT

TRANSFER BALL SCREW IMPLANT ANALOG SCREWDRIVER

(MH120)ANALOG

CLOSED TRAY

HEX. SHORT TRANSFER

HEX. LONG TRANSFER

CIRCULAR SHORT TRANSFER

CIRCULAR LONG TRANSFER

IMPLANT ANALOGOPEN TRAY

TRANSFER LONG SCREW

OPEN TRAY TRANSFER

SHORT SCREWOPEN TRAY

OPEN TRAY IMPRESSION TAKING

Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area.Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a long or short open tray screw using the MH120 screwdriver.Place the drilled transfer area tray (circular or hexagonal) to test the fit. Make sure the screw heads stand out 1 mm and ensure they are easy to reach after taking the impression.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the emerging screws when removing the impression using the MH120 screwdriver.Remove the tray and fix the implant copies very carefully into the impression, then cast the model with type IV clay (ISO 6873).Silicone is recommended when simulating soft tissues. Long transfers (14mm H) will be used when the adjacent teeth have high crown length and when the patient’s mouth opening is broad. Short transfers (10mm H) will be used for short crown lengths and small mouth openings.

Ektos

SCREWDRIVER (MH120)

MICRODENT EKTOS PROSTHESIS MANUAL8

Page 9: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

PROVISIONAL ABUTMENT Necessary material

Multifunction abutment and/or Immediate loading abutment• Multifunction abutments can be used for both single and multiple prosthesis.• Use Immediate loading hexagonal abutments for single restorations (they can also be used for multiple prosthesis) and Immediate loading circular abutments for multiple prosthesis.

IMMEDIATE LOADINGCONICAL HEX.

ABUTMENT

HEXAGONAL TRANSFER

TRANSFER SCREW PROTECTIVE CAP

IMMEDIATE LOADING CONICAL CIRCULAR

ABUTMENT

CIRCULAR TRANSFER

TRANSFER BALL SCREW

TRANSFER BALL SCREW

IMPLANT ANALOG

IMMEDIATE LOADING

ABUTMENT

OPEN TRAY

CLOSED TRAY IMPRESSION TAKING

Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area.Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a closed tray screw using the MH120 screwdriver and cover the screw with the plastic cap to avoid any silicone from entering.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth.Cast the model with type IV clay (ISO 6873) and use silicone if needed.

Necessary material

Ektos

Ektos

Ektos

HEX. MULTIFUNCTION ABUTMENT

OPEN TRAY TRANSFER

LONG SCREW

RETENTION SCREW

MULTIFUNCTION ABUTMENT

SCREWDRIVER (MH120)

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

9

Page 10: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

Cement the prosthesis with the cement suggested for this kind of restorations

AESTHETIC ANGLED

ABUTMENT

CONICAL ABUTMENT

HEXAGONAL

Ektos

Ektos

RETENTION SCREW

RETENTION SCREW

RETENTION SCREW

AESTHETIC ANGLED ABUTMENT

CONICAL ABUTMENT WITH FLAP

CONICAL ABUTMENT WITHOUT FLAP

CEMENTED PROSTHESIS

SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL

Conical abutment hexagonal with and without flap• Recommended for single prosthesis.• The conical abutment can be either with or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. In the conical abutment without flap, the prosthetic crown has to end at 0 mm, in order to lean on the implant platform (like a knife cutting edge). The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. The conical abutment without flap is recommended when there are less than 2 mm of keratineized gum. This is a situation that can cause a difficult aesthetic situation but it is rectifiable with this kind of abutment.

Angled abutment• The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. • Available in three different angles (15º , 20º and 25º). • To maintain the exact position of the implant connection, a hexagonal connection is used.

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

MICRODENT EKTOS PROSTHESIS MANUAL10

Page 11: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

Cement the prosthesis with the cement suggested for this kind of restorations

AESTHETIC ANGLED

ABUTMENT

CONICAL ABUTMENT CIRCULAR

Ektos

Ektos

RETENTION SCREW

RETENTION SCREW

RETENTION SCREW

AESTHETIC ANGLED ABUTMENT

CONICAL ABUTMENT WITH FLAP

CONICAL ABUTMENT WITHOUT FLAP

MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL

Conical abutment circular with and without flap• Recommended for multiple prosthesis.• The conical abutment can be either with flap or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created.

Angled abutment • The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º.• Available in three different angles (15º, 20º and 25º).

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

11

Page 12: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

CEMENT-SCREWED PROSTHESIS

IMPRESSION TAKING: NECESSARY MATERIAL

Mini Capitel abutment transfer and Mini Capitel analog• Place the transfer on the Mini Capitel abutment. Proceed to take impressions with an open or closed tray. Once the impression is done, remove the transfer and drag the impression along with the carrier. Place the Mini Capitel analog in the impression.

PROSTHESIS: NECESSARY MATERIALMini Capitel abutment• Recommended for screwed multiple prosthesis. Mini Capitel abutments allow the complete pros-thesis to be placed and removed even when the implants are not parallel. It is fixed on the platform of the implant, forming a single compact body without the possibility of rotational motion. It allows a compensation of up to 35º between implants (with no greater than 17.5º compensation for either of the two implants) to remedy disparallelism as well as providing a perfect adjustment and a vertical removal of the prosthesis. • Available in different heights: from 1 mm to 4 mm, depending on the platform. • For prosthetic restorations with either the Mini Capitel abutment or the angled Mini Capitel abutment, the same prosthetic accessories are used. • The angled Mini Capitel abutment has an angle between 17º and 30º and a height of 0 mm and 1 mm.

Mini Capitel abutment or angled Mini Capitel abutment• Cementable abutment.

Cementable abutment is common for both Mini Capitel and angled Mini Capitel abutments

Closed tray transfer

Open tray transfer

Closed tray retention screw

Open tray retention screw

ANALOG

EktosTRANSFER

MINI CAPITEL

IMPRESSION TAKING MINI

CAPITEL

MULTIPLE PROSTHESIS MINI CAPITEL

CIRCULAR MINICAPITEL ABUTMENT

ANGLED HEX. MINI CAPITEL ABUTMENT

ABUTMENTAPPLICATOR

CEMENTABLE ABUTMENT

RETENTION SCREW CARRIEREktos

MINI CAPITEL OR ANGLED MINI

CAPITEL

SCREWDRIVER (DL120)

SCREWDRIVER (DL120)

MICRODENT EKTOS PROSTHESIS MANUAL12

Page 13: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

REMOVABLE PROSTHESIS.OVERDENTURESIMPRESSION TAKING: NECESSARY MATERIAL

Osscilia transfer and Osscilia analog• Place the transfer on the Osscilia abutment, which is held by an elastic washer. Proceed to take impressions with an open tray. Once the impression is done, remove the tray and drag the impression along with the carrier. Place the Osscilia analog in the impression.

PROSTHESIS: NECESSARY MATERIALOsscilia abutment• The retainer of the abutments for overdenture retention can be easily exchanged by a practitioner. An Osscilia abutment has a reduced prosthetic height and an emergence diameter of only 3.50 mm.

The complete ensemble is formed by a metallic cap and three different types of interchangeable retainers that are housed inside the metallic cap. Through the employment of a simple key and the screw, the retainers are fixed. Different colors denote different strengths of retention.

Black retainer = soft retention 2 Kg. For use in laboratory trials.White retainer = middle retention 3 Kg. To keep stable for a long period of time.Red retainer = strong retention 4 Kg. Only to be used in special cases when an extreme fixation is required.

IMPRESSION TAKING OSSCILIAOVERDENTURES

PROSTHESIS OSSCILIA

OVERDENTURES

TRANSFER OSSCILIA Ektos

ANALOG OSSCILIATRANSFER OSSCILIA

OSSCILIA Ektos

BLACK RETAINER SOFT RETENTION

STRENGTH

OSSCILIA RETENTION ABUTMENT

SCREWDRIVER (MC220PB)

SCREWDRIVER (DL120)

WHITE RETAINER MIDDLE RETENTION

STRENGTH

RED RETAINER STRONG RETENTION

STRENGTH

METAL CAP

+

SCREWDRIVER (DL120)

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

13

Page 14: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

LABELING CODE SYMBOLOGY

ABUTMENTS

IMPLANTS

Images 1: image of primary packaging of a Microdent Ektos abutment

Images 2: image of secondary packaging of a Microdent Ektos abutment

Image 3: images of primary packaging (right) and secondary packaging (left) for a Microdent Ektos implant

Sterile by irradiation

Device IdentifierUnique DeviceIdentifier (DI&PI)

Endosteal diameter

Lot/batch number

Site for Instructions or Use (IFU) review

Do not use if package is damaged

Expiration date

Reference/article number

Caution: federal law restrics this device to sale by or on the order of a dental professional

Implant type

Do not re-use

Caution, consult accompanying documents

Manufacturer

Two similar labels are included as guidance for practitioners, inside the implant package

MICRODENT EKTOS PROSTHESIS MANUAL14

Page 15: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

INSTRUCTIONS FOR USE In accordance and compliance with legal requirements, all implants manufactured by Implant Microdent System have instructions for use. These instructions are available at www.microdentsystem.com

MRI SAFETY INFORMATIONImplants and abutments have not been evaluated for safety and compatibility in the MR environment. Implants and abutments have not been tested for heating, migration, or image artifact in the MR environment. The safety of implants and abutments in the MR environment is unknown. Scanning a patient who has this device may result in patient injury.

SURGICAL INSTRUMENTSFor a proper use and cleaning of surgical instruments, consult their instructions for use.

GUARANTEE PROGRAM Implant Microdent System provides guarantees for the products it distributes. The terms and conditions of these guarantees are indicated in the Microdent Implant System “Guarantee Program”, consult their instructions for use: www.microdentsystem.com

Two similar labels are included as guidance for practitioners, inside the implant package

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

15

Page 16: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

• Sterilized cover screw supplied in the implant package. • Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 5Ncm.

• Screw can be used with different types of prosthesis.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

• This abutment is intended for further use of Osscilia abutments and conical abutments without flap.• Abutment supplied in sterile state.• Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 25Ncm.

MICRODENT EKTOS ABUTMENTSAll prosthetic abutments are made in titanium grade 5

EKTC35Platform 3.50mm

EKTRHC

EKTC45Platform 4.50mm

EKTC57Platform 5.70mm

MICRODENT EKTOS COVER SCREW

MICRODENT EKTOS RETENTION SCREW

MICRODENT EKTOS HEALING ABUTMENT

EKPCR3502Ø 3.50 height 2mm

EKPCR4502Ø 4.50 height 2mm

EKPCR5702Ø 5.70 height 2mmHealing abutment

EKPCR3503Ø 3.50 height 3mm

EKPCR4503Ø 4.50 height 3mm

EKPCR3504 Ø 3.50 height 4mm

EKPCR4504 Ø 4.50 height 4mm

EKPCR3505Ø 3.50 height 5mm

EKPCR4505Ø 4.50 height 5mm

MICRODENT EKTOS PROSTHESIS MANUAL16

Page 17: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15 Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.

• Abutment supplied in sterile state.• Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 25Ncm.

MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT

EKPR3502Ø 3,50 height 2mm

EKPMF35Ø 3.50 height 0mm

EKPR4502Ø 4.50 height 2mm

EKPR5702Ø 5.70 height 2mm

Multifunction abutment

AestheticHealing abutment

EKPR3503Ø 3,50 height 3mm

EKPMF45Ø 4.50 height 0mm

EKPR4503Ø 4.50 height 3mm

EKPR3504 Ø 3.50 height 4mm

EKPR4504 Ø 4.50 height 4mm

EKPR3505Ø 3.50 height 5mm

EKPR4505Ø 4.50 height 5mm

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

17

Page 18: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.

• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.

Circular

HexagonalMICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP

EKPCCP3501RØ 3.50 height 1mm

EKPCCP4501RØ 4.50 height 1mm

EKPCCP5701RØ 5.70 height 1mm

Conical abutment circular with flap

Conical abutment hexagonal with flap

EKPCCP3503RØ 3.50 height 3mm

EKPCCP4503RØ 4.50 height 3mm

EKPCCP3505R Ø 3.50 height 5mm

EKPCCP4505R Ø 4.50 height 5mm

EKPCCP3501HØ 3.50 height 1mm

EKPCCP4501HØ 4.50 height 1mm

EKPCCP5701HØ 5.70 height 1mm

EKPCCP3503HØ 3.50 height 3mm

EKPCCP4503HØ 4.50 height 3mm

EKPCCP3505H Ø 3.50 height 5mm

EKPCCP4505H Ø 4.50 height 5mm

MICRODENT EKTOS PROSTHESIS MANUAL18

Page 19: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

EKPCSP3500HØ 3.50 height 0mm

Conical abutment hexagonal

without flap

EKPCSP4500H Ø 4.50 height 0mm

EKPCSP5700H Ø 5.70 height 0mm

EKPCSP3501HØ 3.50 height 1mm

EKPCSP4501HØ 4.50 height 1mm

EKPCSP5701HØ 5.70 height 1mm

EKPCSP3502HØ 3.50 height 2mm

EKPCSP4502HØ 4.50 height 2mm

EKPCSP3503HØ 3.50 height 3mm

EKPCSP4503HØ 4.50 height 3mm

EKPCSP3504HØ 3.50 height 4mm

EKPCSP4504HØ 4.50 height 4mm

EKPCSP3505HØ 3.50 height 5mm

EKPCSP4505HØ 4.50 height 5mm

• The screw can be used with all the different types of abutments.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

HexagonalMICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

19

Page 20: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

EKPCSP3500RØ 3.50 height 0mm

EKPCI3500HØ 3.50 height 0mm

HEXAGONAL CIRCULAR

Conical abutment circular without flap

Immediate loadingconical abutment

EKPCSP4500R Ø 4.50 height 0mm

EKPCI3500R Ø 3.50 height 0mm

EKPCSP5700R Ø 5.70 height 0mm

EKPCSP3501RØ 3.50 height 1mm

EKPCI4500HØ 4.50 height 0mm

EKPCSP4501RØ 4.50 height 1mm

EKPCI4500RØ 4.50 height 0mm

EKPCSP5701RØ 5.70 height 1mm

EKPCSP3502RØ 3.50 height 2mm

EKPCI5700HØ 5.70 height0mm

EKPCSP4502RØ 4.50 height 2mm

EKPCI5700RØ 5.70 height 0mm

EKPCSP3503RØ 3.50 height 3mm

EKPCSP4503RØ 4.50 height 3mm

EKPCSP3504RØ 3.50 height 4mm

EKPCSP4504RØ 4.50 height 4mm

EKPCSP3505RØ 3.50 height 5mm

EKPCSP4505RØ 4.50 height 5mm

• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm.

• It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

• Abutment can be cut, accepting minor changes in its design.

MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT

• Abutment supplied with a retention screw. • Use the EKTUCI screw for impression taking when using immediate loading abutments.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.

Circular

MICRODENT EKTOS PROSTHESIS MANUAL20

Page 21: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

EKCAPN3501RØ 3.50 height 1mm

EKPAE3515HØ 3.50 / 15º

Hexagonal Aesthetic Angled abutment

(height 0mm)

Circular Mini Capitel abutment

EKCAPN4501R Ø 4.50 height 1mm

EKPAE4515H Ø 4.50 / 15º

EKPAE5715HØ 5.70 / 15º

EKCAPN5701R Ø 5.70 height 1mm

EKCAPN3502RØ 3.50 height 2mm

EKPAE3520HØ 3.50 / 20º

EKCAPN4502RØ 4.50 height 2mm

EKPAE4520HØ 4.50 / 20º

EKPAE5720HØ 5.70 / 20º

EKCAPN5702RØ 5.70 height 2mm

EKCAPN3503RØ 3.50 height 3mm

EKPAE3525HØ 3.50 / 25º

EKCAPN4503RØ 4.50 height 3mm

EKPAE4525HØ 4.50 / 25º

EKPAE5725HØ 5.70 / 25º

EKCAPN3504RØ 3.50 height 4mm

EKCAPN4504RØ 4.50 height 4mm

MICRODENT EKTOS ANGLED ABUTMENT

MICRODENT EKTOS MINI CAPITEL ABUTMENT

• Abutment supplied with the corresponding screw.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

• Screw in the abutment using the UTSNLEC key.• Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm.

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

21

Page 22: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

EKCAPNA35170HØ 3.50 height 0mm

Hexagonal angled Mini Capitel abutment

EKCAPNA45170HØ 4.50 height 0mm

EKCAPNA35171HØ 3.50 height 1mm

EKCAPNA45171HØ 4.50 height 1mm

EKCAPNA35300HØ 3.50 height 0mm

EKCAPNA45300HØ 4.50 height 0mm

EKCAPNA35301HØ 3.50 height 1mm

EKCAPNA45301HØ 4.50 height 1mm

• Abutment supplied with UTSNATR18 retention screw and PACN positioner.• Use the PACN positioner to facilitate the desired fixation of the abutment.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Do not exceed a torque of 15Ncm for prosthetic retention screws.

ANGLED 17º ANGLED 30º

MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT

MICRODENT EKTOS PROSTHESIS MANUAL22

Page 23: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

PACN Angled Mini Capitel abutment carrier

Material: Stainless steel

UTSNLEC Standard platform

Material: Stainless steel

UTSNLEC1 Wide platform

Material: Stainless steel

UTSNATR18 Angled Mini Capitel retention screw

Material: Titanium grade 5 + DLC

UTSNTRStandard platform

Material: Titanium grade 5 + DLC

UTSNTR1 Wide platform

Material: Titanium grade 5 + DLC

UTSNCP4XStandard platform

Material: Titanium grade 5

UTSNCP51Wide platform

Material: Titanium grade 5

UTSNPC4XStandard platform

Material: Titanium grade 5

UTSNPC51Wide platform

Material: Titanium grade 5

Microdent Ektos Mini Capitel and Angled Mini Capitel abutment components

• These two components are supplied together in the same set with the angled Mini Capitel abutment.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

• Mini Capitel cementable copings cannot be milled.

• Do not exceed a torque of 15Ncm for prosthetic retention screws. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.

MICRODENT EKTOS MINI CAPITEL ABUTMENT FIXING KEY

MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROTECTIVE CAP

MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL CEMENTABLE ABUTMENT

MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROSTHETIC RETENTION SCREW

MICRODENT EKTOS PROSTHESIS MANUAL

ww

w.m

icro

dent

syst

em.c

om

23

Page 24: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

EKEOSS3500Ø 3.50 height 0mm

CSUTGOSSMetal cap with soft, middle and strong retainers

Material: Titanium grade 5 + POM

Osscilia retention abutment

Metal cap with soft, middle or strong Osscilia retainer

EKEOSS3501Ø 3.50 height 1mm

EKEOSS3502Ø 3.50 height 2mm

EKEOSS3503Ø 3.50 height 3mm

EKEOSS4503Ø 4.50 height 3mm

EKEOSS3504Ø 3.50 height 4mm

EKEOSS4504Ø 4.50 height 4mm

EKEOSS4500Ø 4.50 height 0mm

EKEOSS5700Ø 5.70 height 0mm

EKEOSS4501Ø 4.50 height 1mm

EKEOSS5701Ø 5.70 height 1mm

EKEOSS4502Ø 4.50 height 2mm

• Use of a 1.20mm hexagonal screwdriver required to fix the implant.• Do not exceed a torque of 30Ncm.• Do not exceed a maximum non-parallelization of 15° from the vertical.

• Available with three different retention levels, identified by a colored plastic cap:- Black plastic cap: supplied with an embedded metal sheath, it has a soft retention for clinical or laboratory tests.- White plastic cap: it has a medium retention very appropriate to keep stable during a long time period.- Red plastic cap: used in specific cases where extreme fixation is required.

• The key for the Osscilia retainers is a MC220PB.

MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT

MC220PBMicrodent Ektos Osscilia retainer screwdriver

Material: Stainless steel

MICRODENT EKTOS PROSTHESIS MANUAL24

Page 25: PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable prosthesis overdentures. labeling code symbology instructions for use. mri safety information

PROSTHESIS MANUAL