PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable...
Transcript of PROSTHESIS MANUAL · introduction cemented prosthesis. cement-screwed prosthesis. removable...
PROSTHESIS MANUAL
INDEX
PRESENTATION
INTRODUCTION
CEMENTED PROSTHESIS
CEMENT-SCREWED PROSTHESIS
REMOVABLE PROSTHESISOVERDENTURES
LABELING CODE SYMBOLOGY
INSTRUCTIONS FOR USE
MRI SAFETY INFORMATION
SURGICAL INSTRUMENTS
GUARANTEE PROGRAM
CHART OF MICRODENT EKTOS ABUTMENTS IMPRESSION TAKING
PROVISIONAL ABUTMENT
Pag. 05
Pag. 06
Pag. 06
Pag. 12
Pag. 13
Pag. 14
Pag. 15
Pag. 15
Pag. 15
Pag. 15
Pag. 16
Pag. 10
Pag. 08
Pag. 09
Microdent Ektos Cover screw
Microdent Ektos Healing abutment
Microdent Ektos Conical (straight) abutment without flap
Microdent Ektos Conical (straight) abutment with flap
Microdent Ektos multifunction (straight) abutment
Microdent Ektos Immediate loading Conical (straight) abutment
Microdent Ektos Mini Capitel abutment
Microdent Ektos Osscilia retention abutment
Microdent Ektos Retention screw
Microdent Ektos Angled abutment
Microdent Ektos Angled Mini Capitel abutment
PROSTHESIS MANUAL
MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT
SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL
IMPRESSION TAKING: NECESSARY MATERIAL
IMPRESSION TAKING: NECESSARY MATERIAL
ABUTMENTS
MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL
PROSTHESIS: NECESSARY MATERIAL
PROSTHESIS: NECESSARY MATERIAL
IMPLANTS
MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP
MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP
MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT
MICRODENT EKTOS ANGLED ABUTMENT
MICRODENT EKTOS MINI CAPITEL ABUTMENT
MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT
CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION ABUTMENT
MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT
WARNINGS
OPEN TRAY IMPRESSION TAKING
CLOSED TRAY IMPRESSION TAKING
PRESENTATION
Implant Microdent System S.L. is a company that, from its creation in 1983, has specialized in developing, manufacturing and marketing components for odontological treatments, and, specially, oral implantology.
Always striving for customer satisfaction, Microdent offers all the guarantee, both of quality and service, backed up by its long and ascending professional history in the field of oral implantology.
The periodical offer of formation courses for professionals of the implantology field and the existence of a collaboration and assessment team allows Microdent to have products that verify the most strict quality parameters stablished, as well as to satisfy the needs of its clients.
Microdent has modern facilities equipped with the most cutting-edge technology, thus making Microdent into one of the pioneer companies in the research and manufacture of solutions for oral implantology. The patents obtained by Microdent products demonstrate the continued dedication of the company to the research work.
MICRODENT EKTOS PROSTHESIS MANUAL 5
INTRODUCTION
PROSTHESIS MANUALThis manual informs dental practitioners and prosthetists of the different Microdent Implant System abutments available to make a dental prosthesis.
This prosthetic manual suggests which Microdent Ektos abutment should be used depending on the situation and/or requirements of the patient.
The use of the strict protocols described in this manual guarantees the efficacy of the Microdent products.
Microdent Ektos With internal hexagonal connection
WARNINGS
MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT
• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. • The multifunction abutment is characterized by its multiple functionality: implant holder, transfer and provisional abutment.• The multifunction abutment is supplied with the implant and cover screw in their own packaging in a sterile state.• The multifunction abutment is connected to the implant through the employment of a prosthetic screw, which is also presented in a sterile state.• The upper part of the abutment has a hexagonal socket to accomodate a tool for:- Implant and abutment extraction from the container.- Implant transport from the container to the insertion point.
MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP
• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.
MICRODENT EKTOS PROSTHESIS MANUAL6
MICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP
• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment.• While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.
MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT
• A retention screw is provided in the container with the abutment. • Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. • While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis.
MICRODENT EKTOS ANGLED ABUTMENT
• A retention screw is provided in the container with the abutment.• Do not to exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.• The abutment cannot be modified.• Angled abutments are not recommended for the posterior region of the mouth.
MICRODENT EKTOS MINI CAPITEL ABUTMENT
• Use the UTSNLEC / UTSNLEC51 keys to screw the abutment and the implant together.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.
MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT
• The UTSNATR18 retention screw and the PACN carrier are provided in the container with the angled Mini Capitel abutment.• Use the PACN carrier to fix angled Mini Capitel abutment to its desired position.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended.
MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT
• The use of the hex. 1.20 screwdriver is required to join the product and the implant together.• Do not exceed a torque of 30 Ncm for the final fixation of the abutment.• Do not exceed a disparallelism of 17º between implants.• The exchange of retainers is facilitated through the use of the MC220PB screwdriver.• The retainers are identified by color. The different colors denote different retentive strengths. - Black retainer = soft retention strength 2Kg. For use in laboratory trials. - White retainer = middle retention strength 3Kg. To keep stable for a long period of time. - Red retainer = strong retention strength 4Kg. Only to be used in special cases where an extreme
fixation is required.
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
7
IMPRESSION TAKING
CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION ABUTMENT
A multifunction abutment can be used for taking impressions with a closed tray.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth.Cast the model with type IV clay (ISO 6873) and use silicone if needed.
Necessary material
Necessary material
Ektos
HEX. MULTIFUNCTION ABUTMENT
TRANSFER BALL SCREW IMPLANT ANALOG SCREWDRIVER
(MH120)ANALOG
CLOSED TRAY
HEX. SHORT TRANSFER
HEX. LONG TRANSFER
CIRCULAR SHORT TRANSFER
CIRCULAR LONG TRANSFER
IMPLANT ANALOGOPEN TRAY
TRANSFER LONG SCREW
OPEN TRAY TRANSFER
SHORT SCREWOPEN TRAY
OPEN TRAY IMPRESSION TAKING
Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area.Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a long or short open tray screw using the MH120 screwdriver.Place the drilled transfer area tray (circular or hexagonal) to test the fit. Make sure the screw heads stand out 1 mm and ensure they are easy to reach after taking the impression.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the emerging screws when removing the impression using the MH120 screwdriver.Remove the tray and fix the implant copies very carefully into the impression, then cast the model with type IV clay (ISO 6873).Silicone is recommended when simulating soft tissues. Long transfers (14mm H) will be used when the adjacent teeth have high crown length and when the patient’s mouth opening is broad. Short transfers (10mm H) will be used for short crown lengths and small mouth openings.
Ektos
SCREWDRIVER (MH120)
MICRODENT EKTOS PROSTHESIS MANUAL8
PROVISIONAL ABUTMENT Necessary material
Multifunction abutment and/or Immediate loading abutment• Multifunction abutments can be used for both single and multiple prosthesis.• Use Immediate loading hexagonal abutments for single restorations (they can also be used for multiple prosthesis) and Immediate loading circular abutments for multiple prosthesis.
IMMEDIATE LOADINGCONICAL HEX.
ABUTMENT
HEXAGONAL TRANSFER
TRANSFER SCREW PROTECTIVE CAP
IMMEDIATE LOADING CONICAL CIRCULAR
ABUTMENT
CIRCULAR TRANSFER
TRANSFER BALL SCREW
TRANSFER BALL SCREW
IMPLANT ANALOG
IMMEDIATE LOADING
ABUTMENT
OPEN TRAY
CLOSED TRAY IMPRESSION TAKING
Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area.Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a closed tray screw using the MH120 screwdriver and cover the screw with the plastic cap to avoid any silicone from entering.After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression.Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth.Cast the model with type IV clay (ISO 6873) and use silicone if needed.
Necessary material
Ektos
Ektos
Ektos
HEX. MULTIFUNCTION ABUTMENT
OPEN TRAY TRANSFER
LONG SCREW
RETENTION SCREW
MULTIFUNCTION ABUTMENT
SCREWDRIVER (MH120)
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
9
Cement the prosthesis with the cement suggested for this kind of restorations
AESTHETIC ANGLED
ABUTMENT
CONICAL ABUTMENT
HEXAGONAL
Ektos
Ektos
RETENTION SCREW
RETENTION SCREW
RETENTION SCREW
AESTHETIC ANGLED ABUTMENT
CONICAL ABUTMENT WITH FLAP
CONICAL ABUTMENT WITHOUT FLAP
CEMENTED PROSTHESIS
SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL
Conical abutment hexagonal with and without flap• Recommended for single prosthesis.• The conical abutment can be either with or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. In the conical abutment without flap, the prosthetic crown has to end at 0 mm, in order to lean on the implant platform (like a knife cutting edge). The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. The conical abutment without flap is recommended when there are less than 2 mm of keratineized gum. This is a situation that can cause a difficult aesthetic situation but it is rectifiable with this kind of abutment.
Angled abutment• The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. • Available in three different angles (15º , 20º and 25º). • To maintain the exact position of the implant connection, a hexagonal connection is used.
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
MICRODENT EKTOS PROSTHESIS MANUAL10
Cement the prosthesis with the cement suggested for this kind of restorations
AESTHETIC ANGLED
ABUTMENT
CONICAL ABUTMENT CIRCULAR
Ektos
Ektos
RETENTION SCREW
RETENTION SCREW
RETENTION SCREW
AESTHETIC ANGLED ABUTMENT
CONICAL ABUTMENT WITH FLAP
CONICAL ABUTMENT WITHOUT FLAP
MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL
Conical abutment circular with and without flap• Recommended for multiple prosthesis.• The conical abutment can be either with flap or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created.
Angled abutment • The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º.• Available in three different angles (15º, 20º and 25º).
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
11
CEMENT-SCREWED PROSTHESIS
IMPRESSION TAKING: NECESSARY MATERIAL
Mini Capitel abutment transfer and Mini Capitel analog• Place the transfer on the Mini Capitel abutment. Proceed to take impressions with an open or closed tray. Once the impression is done, remove the transfer and drag the impression along with the carrier. Place the Mini Capitel analog in the impression.
PROSTHESIS: NECESSARY MATERIALMini Capitel abutment• Recommended for screwed multiple prosthesis. Mini Capitel abutments allow the complete pros-thesis to be placed and removed even when the implants are not parallel. It is fixed on the platform of the implant, forming a single compact body without the possibility of rotational motion. It allows a compensation of up to 35º between implants (with no greater than 17.5º compensation for either of the two implants) to remedy disparallelism as well as providing a perfect adjustment and a vertical removal of the prosthesis. • Available in different heights: from 1 mm to 4 mm, depending on the platform. • For prosthetic restorations with either the Mini Capitel abutment or the angled Mini Capitel abutment, the same prosthetic accessories are used. • The angled Mini Capitel abutment has an angle between 17º and 30º and a height of 0 mm and 1 mm.
Mini Capitel abutment or angled Mini Capitel abutment• Cementable abutment.
Cementable abutment is common for both Mini Capitel and angled Mini Capitel abutments
Closed tray transfer
Open tray transfer
Closed tray retention screw
Open tray retention screw
ANALOG
EktosTRANSFER
MINI CAPITEL
IMPRESSION TAKING MINI
CAPITEL
MULTIPLE PROSTHESIS MINI CAPITEL
CIRCULAR MINICAPITEL ABUTMENT
ANGLED HEX. MINI CAPITEL ABUTMENT
ABUTMENTAPPLICATOR
CEMENTABLE ABUTMENT
RETENTION SCREW CARRIEREktos
MINI CAPITEL OR ANGLED MINI
CAPITEL
SCREWDRIVER (DL120)
SCREWDRIVER (DL120)
MICRODENT EKTOS PROSTHESIS MANUAL12
REMOVABLE PROSTHESIS.OVERDENTURESIMPRESSION TAKING: NECESSARY MATERIAL
Osscilia transfer and Osscilia analog• Place the transfer on the Osscilia abutment, which is held by an elastic washer. Proceed to take impressions with an open tray. Once the impression is done, remove the tray and drag the impression along with the carrier. Place the Osscilia analog in the impression.
PROSTHESIS: NECESSARY MATERIALOsscilia abutment• The retainer of the abutments for overdenture retention can be easily exchanged by a practitioner. An Osscilia abutment has a reduced prosthetic height and an emergence diameter of only 3.50 mm.
The complete ensemble is formed by a metallic cap and three different types of interchangeable retainers that are housed inside the metallic cap. Through the employment of a simple key and the screw, the retainers are fixed. Different colors denote different strengths of retention.
Black retainer = soft retention 2 Kg. For use in laboratory trials.White retainer = middle retention 3 Kg. To keep stable for a long period of time.Red retainer = strong retention 4 Kg. Only to be used in special cases when an extreme fixation is required.
IMPRESSION TAKING OSSCILIAOVERDENTURES
PROSTHESIS OSSCILIA
OVERDENTURES
TRANSFER OSSCILIA Ektos
ANALOG OSSCILIATRANSFER OSSCILIA
OSSCILIA Ektos
BLACK RETAINER SOFT RETENTION
STRENGTH
OSSCILIA RETENTION ABUTMENT
SCREWDRIVER (MC220PB)
SCREWDRIVER (DL120)
WHITE RETAINER MIDDLE RETENTION
STRENGTH
RED RETAINER STRONG RETENTION
STRENGTH
METAL CAP
+
SCREWDRIVER (DL120)
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
13
LABELING CODE SYMBOLOGY
ABUTMENTS
IMPLANTS
Images 1: image of primary packaging of a Microdent Ektos abutment
Images 2: image of secondary packaging of a Microdent Ektos abutment
Image 3: images of primary packaging (right) and secondary packaging (left) for a Microdent Ektos implant
Sterile by irradiation
Device IdentifierUnique DeviceIdentifier (DI&PI)
Endosteal diameter
Lot/batch number
Site for Instructions or Use (IFU) review
Do not use if package is damaged
Expiration date
Reference/article number
Caution: federal law restrics this device to sale by or on the order of a dental professional
Implant type
Do not re-use
Caution, consult accompanying documents
Manufacturer
Two similar labels are included as guidance for practitioners, inside the implant package
MICRODENT EKTOS PROSTHESIS MANUAL14
INSTRUCTIONS FOR USE In accordance and compliance with legal requirements, all implants manufactured by Implant Microdent System have instructions for use. These instructions are available at www.microdentsystem.com
MRI SAFETY INFORMATIONImplants and abutments have not been evaluated for safety and compatibility in the MR environment. Implants and abutments have not been tested for heating, migration, or image artifact in the MR environment. The safety of implants and abutments in the MR environment is unknown. Scanning a patient who has this device may result in patient injury.
SURGICAL INSTRUMENTSFor a proper use and cleaning of surgical instruments, consult their instructions for use.
GUARANTEE PROGRAM Implant Microdent System provides guarantees for the products it distributes. The terms and conditions of these guarantees are indicated in the Microdent Implant System “Guarantee Program”, consult their instructions for use: www.microdentsystem.com
Two similar labels are included as guidance for practitioners, inside the implant package
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
15
• Sterilized cover screw supplied in the implant package. • Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 5Ncm.
• Screw can be used with different types of prosthesis.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
• This abutment is intended for further use of Osscilia abutments and conical abutments without flap.• Abutment supplied in sterile state.• Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 25Ncm.
MICRODENT EKTOS ABUTMENTSAll prosthetic abutments are made in titanium grade 5
EKTC35Platform 3.50mm
EKTRHC
EKTC45Platform 4.50mm
EKTC57Platform 5.70mm
MICRODENT EKTOS COVER SCREW
MICRODENT EKTOS RETENTION SCREW
MICRODENT EKTOS HEALING ABUTMENT
EKPCR3502Ø 3.50 height 2mm
EKPCR4502Ø 4.50 height 2mm
EKPCR5702Ø 5.70 height 2mmHealing abutment
EKPCR3503Ø 3.50 height 3mm
EKPCR4503Ø 4.50 height 3mm
EKPCR3504 Ø 3.50 height 4mm
EKPCR4504 Ø 4.50 height 4mm
EKPCR3505Ø 3.50 height 5mm
EKPCR4505Ø 4.50 height 5mm
MICRODENT EKTOS PROSTHESIS MANUAL16
• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15 Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.
• Abutment supplied in sterile state.• Use of a 1.20mm hexagonal screwdriver required.• Do not cement the cover screw to the implant.• Do not exceed a torque of 25Ncm.
MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) ABUTMENT
EKPR3502Ø 3,50 height 2mm
EKPMF35Ø 3.50 height 0mm
EKPR4502Ø 4.50 height 2mm
EKPR5702Ø 5.70 height 2mm
Multifunction abutment
AestheticHealing abutment
EKPR3503Ø 3,50 height 3mm
EKPMF45Ø 4.50 height 0mm
EKPR4503Ø 4.50 height 3mm
EKPR3504 Ø 3.50 height 4mm
EKPR4504 Ø 4.50 height 4mm
EKPR3505Ø 3.50 height 5mm
EKPR4505Ø 4.50 height 5mm
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
17
• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.
• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.
Circular
HexagonalMICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITH FLAP
EKPCCP3501RØ 3.50 height 1mm
EKPCCP4501RØ 4.50 height 1mm
EKPCCP5701RØ 5.70 height 1mm
Conical abutment circular with flap
Conical abutment hexagonal with flap
EKPCCP3503RØ 3.50 height 3mm
EKPCCP4503RØ 4.50 height 3mm
EKPCCP3505R Ø 3.50 height 5mm
EKPCCP4505R Ø 4.50 height 5mm
EKPCCP3501HØ 3.50 height 1mm
EKPCCP4501HØ 4.50 height 1mm
EKPCCP5701HØ 5.70 height 1mm
EKPCCP3503HØ 3.50 height 3mm
EKPCCP4503HØ 4.50 height 3mm
EKPCCP3505H Ø 3.50 height 5mm
EKPCCP4505H Ø 4.50 height 5mm
MICRODENT EKTOS PROSTHESIS MANUAL18
EKPCSP3500HØ 3.50 height 0mm
Conical abutment hexagonal
without flap
EKPCSP4500H Ø 4.50 height 0mm
EKPCSP5700H Ø 5.70 height 0mm
EKPCSP3501HØ 3.50 height 1mm
EKPCSP4501HØ 4.50 height 1mm
EKPCSP5701HØ 5.70 height 1mm
EKPCSP3502HØ 3.50 height 2mm
EKPCSP4502HØ 4.50 height 2mm
EKPCSP3503HØ 3.50 height 3mm
EKPCSP4503HØ 4.50 height 3mm
EKPCSP3504HØ 3.50 height 4mm
EKPCSP4504HØ 4.50 height 4mm
EKPCSP3505HØ 3.50 height 5mm
EKPCSP4505HØ 4.50 height 5mm
• The screw can be used with all the different types of abutments.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
HexagonalMICRODENT EKTOS CONICAL (STRAIGHT) ABUTMENT WITHOUT FLAP
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
19
EKPCSP3500RØ 3.50 height 0mm
EKPCI3500HØ 3.50 height 0mm
HEXAGONAL CIRCULAR
Conical abutment circular without flap
Immediate loadingconical abutment
EKPCSP4500R Ø 4.50 height 0mm
EKPCI3500R Ø 3.50 height 0mm
EKPCSP5700R Ø 5.70 height 0mm
EKPCSP3501RØ 3.50 height 1mm
EKPCI4500HØ 4.50 height 0mm
EKPCSP4501RØ 4.50 height 1mm
EKPCI4500RØ 4.50 height 0mm
EKPCSP5701RØ 5.70 height 1mm
EKPCSP3502RØ 3.50 height 2mm
EKPCI5700HØ 5.70 height0mm
EKPCSP4502RØ 4.50 height 2mm
EKPCI5700RØ 5.70 height 0mm
EKPCSP3503RØ 3.50 height 3mm
EKPCSP4503RØ 4.50 height 3mm
EKPCSP3504RØ 3.50 height 4mm
EKPCSP4504RØ 4.50 height 4mm
EKPCSP3505RØ 3.50 height 5mm
EKPCSP4505RØ 4.50 height 5mm
• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm.
• It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
• Abutment can be cut, accepting minor changes in its design.
MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) ABUTMENT
• Abutment supplied with a retention screw. • Use the EKTUCI screw for impression taking when using immediate loading abutments.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Abutment can be cut, accepting minor changes in its design.
Circular
MICRODENT EKTOS PROSTHESIS MANUAL20
EKCAPN3501RØ 3.50 height 1mm
EKPAE3515HØ 3.50 / 15º
Hexagonal Aesthetic Angled abutment
(height 0mm)
Circular Mini Capitel abutment
EKCAPN4501R Ø 4.50 height 1mm
EKPAE4515H Ø 4.50 / 15º
EKPAE5715HØ 5.70 / 15º
EKCAPN5701R Ø 5.70 height 1mm
EKCAPN3502RØ 3.50 height 2mm
EKPAE3520HØ 3.50 / 20º
EKCAPN4502RØ 4.50 height 2mm
EKPAE4520HØ 4.50 / 20º
EKPAE5720HØ 5.70 / 20º
EKCAPN5702RØ 5.70 height 2mm
EKCAPN3503RØ 3.50 height 3mm
EKPAE3525HØ 3.50 / 25º
EKCAPN4503RØ 4.50 height 3mm
EKPAE4525HØ 4.50 / 25º
EKPAE5725HØ 5.70 / 25º
EKCAPN3504RØ 3.50 height 4mm
EKCAPN4504RØ 4.50 height 4mm
MICRODENT EKTOS ANGLED ABUTMENT
MICRODENT EKTOS MINI CAPITEL ABUTMENT
• Abutment supplied with the corresponding screw.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
• Screw in the abutment using the UTSNLEC key.• Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm.
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
21
EKCAPNA35170HØ 3.50 height 0mm
Hexagonal angled Mini Capitel abutment
EKCAPNA45170HØ 4.50 height 0mm
EKCAPNA35171HØ 3.50 height 1mm
EKCAPNA45171HØ 4.50 height 1mm
EKCAPNA35300HØ 3.50 height 0mm
EKCAPNA45300HØ 4.50 height 0mm
EKCAPNA35301HØ 3.50 height 1mm
EKCAPNA45301HØ 4.50 height 1mm
• Abutment supplied with UTSNATR18 retention screw and PACN positioner.• Use the PACN positioner to facilitate the desired fixation of the abutment.• Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.• Do not exceed a torque of 15Ncm for prosthetic retention screws.
ANGLED 17º ANGLED 30º
MICRODENT EKTOS ANGLED MINI CAPITEL ABUTMENT
MICRODENT EKTOS PROSTHESIS MANUAL22
PACN Angled Mini Capitel abutment carrier
Material: Stainless steel
UTSNLEC Standard platform
Material: Stainless steel
UTSNLEC1 Wide platform
Material: Stainless steel
UTSNATR18 Angled Mini Capitel retention screw
Material: Titanium grade 5 + DLC
UTSNTRStandard platform
Material: Titanium grade 5 + DLC
UTSNTR1 Wide platform
Material: Titanium grade 5 + DLC
UTSNCP4XStandard platform
Material: Titanium grade 5
UTSNCP51Wide platform
Material: Titanium grade 5
UTSNPC4XStandard platform
Material: Titanium grade 5
UTSNPC51Wide platform
Material: Titanium grade 5
Microdent Ektos Mini Capitel and Angled Mini Capitel abutment components
• These two components are supplied together in the same set with the angled Mini Capitel abutment.• Use of a 1.20mm hexagonal screwdriver required.• Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
• Mini Capitel cementable copings cannot be milled.
• Do not exceed a torque of 15Ncm for prosthetic retention screws. • It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones.
MICRODENT EKTOS MINI CAPITEL ABUTMENT FIXING KEY
MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROTECTIVE CAP
MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL CEMENTABLE ABUTMENT
MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROSTHETIC RETENTION SCREW
MICRODENT EKTOS PROSTHESIS MANUAL
ww
w.m
icro
dent
syst
em.c
om
23
EKEOSS3500Ø 3.50 height 0mm
CSUTGOSSMetal cap with soft, middle and strong retainers
Material: Titanium grade 5 + POM
Osscilia retention abutment
Metal cap with soft, middle or strong Osscilia retainer
EKEOSS3501Ø 3.50 height 1mm
EKEOSS3502Ø 3.50 height 2mm
EKEOSS3503Ø 3.50 height 3mm
EKEOSS4503Ø 4.50 height 3mm
EKEOSS3504Ø 3.50 height 4mm
EKEOSS4504Ø 4.50 height 4mm
EKEOSS4500Ø 4.50 height 0mm
EKEOSS5700Ø 5.70 height 0mm
EKEOSS4501Ø 4.50 height 1mm
EKEOSS5701Ø 5.70 height 1mm
EKEOSS4502Ø 4.50 height 2mm
• Use of a 1.20mm hexagonal screwdriver required to fix the implant.• Do not exceed a torque of 30Ncm.• Do not exceed a maximum non-parallelization of 15° from the vertical.
• Available with three different retention levels, identified by a colored plastic cap:- Black plastic cap: supplied with an embedded metal sheath, it has a soft retention for clinical or laboratory tests.- White plastic cap: it has a medium retention very appropriate to keep stable during a long time period.- Red plastic cap: used in specific cases where extreme fixation is required.
• The key for the Osscilia retainers is a MC220PB.
MICRODENT EKTOS OSSCILIA RETENTION ABUTMENT
MC220PBMicrodent Ektos Osscilia retainer screwdriver
Material: Stainless steel
MICRODENT EKTOS PROSTHESIS MANUAL24
PROSTHESIS MANUAL