Proposal of “Large Space Cooling” by MOISTURE MIST (Tokyo skytree) Futaba Lease Co., Ltd. Dragon inc Co., Ltd

description

This is a mist machine, which can do evaporative cooling in an extensive range of indoor and outdoor with moist and soft fog. The high quality evaporative cooling effect which Moisture Mist has is possible to cool not only the outdoor, but also indoor use will lower the use of air conditioner and also reduce CO2. It is able to be operated in 100 Volt and therefore, the mobile installation will be easy. There are lots of actual use, start from bureaucracy like Tokyo Metropolitan Bureau of Environment, Kitakyushu city, Kobe Waterworks Bureau, etc., there also Ueno Zoo, whole country’s highway, train station, department store, events, etc. It shows the effectiveness of large space cooling better than spot cooler or electric fan.

Transcript of Proposal of moisture mist (english ver.)v1.1

Page 1: Proposal of moisture mist (english ver.)v1.1

Proposal of “Large Space Cooling”

by

MOISTURE MIST

(Tokyo skytree)

Futaba Lease Co., Ltd.

Dragon inc Co., Ltd

Page 2: Proposal of moisture mist (english ver.)v1.1

1.About cooling by Moisture Mist

This is a mist machine, which can do evaporative cooling in an extensive range of indoor and

outdoor with moist and soft fog.

The high quality evaporative cooling effect which Moisture Mist has is possible to cool not only the

outdoor, but also indoor use will lower the use of air conditioner and also reduce CO2.

It is able to be operated in 100 Volt and therefore, the mobile installation will be easy.

There are lots of actual use, start from bureaucracy like Tokyo Metropolitan Bureau of Environment,

Kitakyushu city, Kobe Waterworks Bureau, etc., there also Ueno Zoo, whole country’s highway, train

station, department store, events, etc.

It shows the effectiveness of large space cooling better than spot cooler or electric fan.

Page 3: Proposal of moisture mist (english ver.)v1.1

2.Moisture Mist

There are 2 types of Moisture Mist, which we will mention its ability below.

It is a system, which deliver increased pressured water to the Moisture Mist unit with dedicated

plunger pump in order to generate mist, and then diffuse spray in a straight line with the axial flow

fan.

Table1 MM12-SF

Table 2 MM6-SF

3.Moisture Mist Fundamental

In order to create the average particle size of 12 m mist with 1 flow operation , we have developed our own original nozzle. The made-in-μceramic nozzle tip comes with a spray method, which spray water pressure 9.8Mpa from 0.1mm diameter of aperture. Each nozzle’s spray

volume is 50cc/min; and it comes with unique construction, which can diffuse above 70 degree of spray angle.

The dedicated plunger pump’s discharge rate is low and it supplies high-pressured water to the nozzle. Moisture Mist is integrated with blower;

while diffuse the mist that sprayed from nozzle in a linear way to the distant, it also send cool breeze that have been through evaporative

Moisture Mist & Plunger Pump

Spray Volume 36L/h (Adjustable)Blast volume m3/h

(50Hz/60Hz)2,400/2,880

Effective cooling area

About 240m2

Minus Ion About 23,000 negative ions/cc

Noise About 55dBMotor Output(50Hz/60Hz)

AC100V・230/320W

Electric Current(50Hz/60Hz)

3.8A/3.4A

Weight(Unit only)

50kg

Exterior dimensions (cm)

φ42×length 126

Moisture Mist (Mini)

Spray Volume 18L/h (Adjustable)Blast Volume m3/h

(50Hz/60Hz)588/702

Effective cooling area

About 60m2

Minus Ion About 11,500 negative ions/cc

Noise About 50dBMotor Output(50Hz/60Hz)

AC100V・80/100W

Electric Current(50Hz/60Hz)

1.23A/1.11A

Weight(Unit only)

16kg

Exterior dimension (cm)

φ30×length 48

Page 4: Proposal of moisture mist (english ver.)v1.1

cooling and spread it into cooling range effectively.

4.Running Cost (50Hz region)

We have calculated based on one month running cost in condition of 8 hours operation in a day and on summertime.

The electricity charge and water charge is based on Tokyo area general charge.※

Table 3 Running Cost Trial Calculation Sheet

Machine type MM12-FS MM6-FS

Effective cooling

range *8m×30m=240m2 6m×20m=140m2

Electri

city

Volu

me

Fan 30(day)×8(hour)×0.1kw=24kw 30(day)×8(hour)×0.2kw=48kw

Pump 30(day)×8(hour)×0.75kw=180kw 30(day)×8(hour)×0.75kw=180kw

Water

Volu

me

Spray

Volume

30(day)×8(hour)× 18L=4,320L 30(day)×8(hour)× 36L=8,640L

Electricity Charge 16 Yen×228kw=3,648 Yen 16 Yen×208kw=3,328 Yen

Water Charge 0.2 Yen×8,640L=1,728 Yen 0.2 Yen×4,320L=864 Yen

Total Fee 5,376 Yen (About 180 Yen/day) 4,192 Yen (About 139 Yen/day)

Unit price/㎡ 22.4 Yen/m2 29.9 Yen/m2

The effective cooling range is based in a closed room with no wind condition. *      

Page 5: Proposal of moisture mist (english ver.)v1.1

5.Cooling Effect

Below is the display of change of temperature in with case when received the mist in most effective position

with thermograph.

Before spray thermography 35.1℃ After spray thermography 29.9℃

(Before) 35.1℃ → (After) 29.9℃ -5.5℃(Temperature lowered)

The picture above shows the change of temperature after using Moisture Mist. We can confirm that the

temperature of surface which being hit by the mist is lowered.

We cannot put the room temperature constantly, but the temperature around the room is lowered.

Page 6: Proposal of moisture mist (english ver.)v1.1

6.Implementation Example

Implementation example of cooling field by Moisture Mist.

We have lots of actual uses, start with train platform, rooftop, semi-outdoor, indoor, etc.

JR Okuyama Train Station

Conventional Line Platform

JR Maihama Train Station Near the ticket selling

counter (Disneyland Train Station)

Nankai Nanba Train Station1 F Concourse Isetan Shinjuku Branch Rooftop

Large suburbs store Ginza 5-chome Street

Page 7: Proposal of moisture mist (english ver.)v1.1

(Between Hermes and Sony store)

7.Performance measurement of concourse cooling

The result of cooling effect test in the train station concourse.

1) Condition of Moisture Mist placement

Spray from 2 unit of MM12-SF from the front of escalator to the direction of concourse near the ticket-

selling counter

Place 2 units of Moisture Mist Unit look from behind

2)Measurement position

We have tested the temperature and humidity in the middle of concourse near of the ticket-selling

counter.

About 15 meter from the Moisture Mist position.

Before use Temperature 30.3℃

Humidity 58.4%

5 minutes after useTemperature 27.0℃

Humidity 69.3%

(Before) 30.3℃ → (After use) 27.0℃  -3.3℃ (Temperature lowered)

Moisture Mist is able to raise the cooling effect which cooler or spot cooler cannot do.

Page 8: Proposal of moisture mist (english ver.)v1.1
Page 9: Proposal of moisture mist (english ver.)v1.1

8.Recommendation

We recommend you to use the cool breeze cooling of Moisture Mist.

Because of its natural coolness which, has humidity, it will not burden your body; just like a cooler

that is friendly to our body.

The use of multiple units can lower the surrounding temperature.

9.Moisture Mist Cost

Table1 MM12-SF MM6-SF

MM12-SF MM6-SF

Page 10: Proposal of moisture mist (english ver.)v1.1

8.Recommendation

We recommend you to use the cool breeze cooling of Moisture Mist.

Because of its natural coolness which, has humidity, it will not burden your body; just like a cooler

that is friendly to our body.

The use of multiple units can lower the surrounding temperature.

9.Moisture Mist Cost

Table1 MM12-SF MM6-SF

MM12-SF MM6-SF