Proposal of “Large Space Cooling”
by
MOISTURE MIST
(Tokyo skytree)
Futaba Lease Co., Ltd.
Dragon inc Co., Ltd
1.About cooling by Moisture Mist
This is a mist machine, which can do evaporative cooling in an extensive range of indoor and
outdoor with moist and soft fog.
The high quality evaporative cooling effect which Moisture Mist has is possible to cool not only the
outdoor, but also indoor use will lower the use of air conditioner and also reduce CO2.
It is able to be operated in 100 Volt and therefore, the mobile installation will be easy.
There are lots of actual use, start from bureaucracy like Tokyo Metropolitan Bureau of Environment,
Kitakyushu city, Kobe Waterworks Bureau, etc., there also Ueno Zoo, whole country’s highway, train
station, department store, events, etc.
It shows the effectiveness of large space cooling better than spot cooler or electric fan.
2.Moisture Mist
There are 2 types of Moisture Mist, which we will mention its ability below.
It is a system, which deliver increased pressured water to the Moisture Mist unit with dedicated
plunger pump in order to generate mist, and then diffuse spray in a straight line with the axial flow
fan.
Table1 MM12-SF
Table 2 MM6-SF
3.Moisture Mist Fundamental
In order to create the average particle size of 12 m mist with 1 flow operation , we have developed our own original nozzle. The made-in-μceramic nozzle tip comes with a spray method, which spray water pressure 9.8Mpa from 0.1mm diameter of aperture. Each nozzle’s spray
volume is 50cc/min; and it comes with unique construction, which can diffuse above 70 degree of spray angle.
The dedicated plunger pump’s discharge rate is low and it supplies high-pressured water to the nozzle. Moisture Mist is integrated with blower;
while diffuse the mist that sprayed from nozzle in a linear way to the distant, it also send cool breeze that have been through evaporative
Moisture Mist & Plunger Pump
Spray Volume 36L/h (Adjustable)Blast volume m3/h
(50Hz/60Hz)2,400/2,880
Effective cooling area
About 240m2
Minus Ion About 23,000 negative ions/cc
Noise About 55dBMotor Output(50Hz/60Hz)
AC100V・230/320W
Electric Current(50Hz/60Hz)
3.8A/3.4A
Weight(Unit only)
50kg
Exterior dimensions (cm)
φ42×length 126
Moisture Mist (Mini)
Spray Volume 18L/h (Adjustable)Blast Volume m3/h
(50Hz/60Hz)588/702
Effective cooling area
About 60m2
Minus Ion About 11,500 negative ions/cc
Noise About 50dBMotor Output(50Hz/60Hz)
AC100V・80/100W
Electric Current(50Hz/60Hz)
1.23A/1.11A
Weight(Unit only)
16kg
Exterior dimension (cm)
φ30×length 48
cooling and spread it into cooling range effectively.
4.Running Cost (50Hz region)
We have calculated based on one month running cost in condition of 8 hours operation in a day and on summertime.
The electricity charge and water charge is based on Tokyo area general charge.※
Table 3 Running Cost Trial Calculation Sheet
Machine type MM12-FS MM6-FS
Effective cooling
range *8m×30m=240m2 6m×20m=140m2
Electri
city
Volu
me
Fan 30(day)×8(hour)×0.1kw=24kw 30(day)×8(hour)×0.2kw=48kw
Pump 30(day)×8(hour)×0.75kw=180kw 30(day)×8(hour)×0.75kw=180kw
Water
Volu
me
Spray
Volume
30(day)×8(hour)× 18L=4,320L 30(day)×8(hour)× 36L=8,640L
Electricity Charge 16 Yen×228kw=3,648 Yen 16 Yen×208kw=3,328 Yen
Water Charge 0.2 Yen×8,640L=1,728 Yen 0.2 Yen×4,320L=864 Yen
Total Fee 5,376 Yen (About 180 Yen/day) 4,192 Yen (About 139 Yen/day)
Unit price/㎡ 22.4 Yen/m2 29.9 Yen/m2
The effective cooling range is based in a closed room with no wind condition. *
5.Cooling Effect
Below is the display of change of temperature in with case when received the mist in most effective position
with thermograph.
Before spray thermography 35.1℃ After spray thermography 29.9℃
(Before) 35.1℃ → (After) 29.9℃ -5.5℃(Temperature lowered)
The picture above shows the change of temperature after using Moisture Mist. We can confirm that the
temperature of surface which being hit by the mist is lowered.
We cannot put the room temperature constantly, but the temperature around the room is lowered.
6.Implementation Example
Implementation example of cooling field by Moisture Mist.
We have lots of actual uses, start with train platform, rooftop, semi-outdoor, indoor, etc.
JR Okuyama Train Station
Conventional Line Platform
JR Maihama Train Station Near the ticket selling
counter (Disneyland Train Station)
Nankai Nanba Train Station1 F Concourse Isetan Shinjuku Branch Rooftop
Large suburbs store Ginza 5-chome Street
(Between Hermes and Sony store)
7.Performance measurement of concourse cooling
The result of cooling effect test in the train station concourse.
1) Condition of Moisture Mist placement
Spray from 2 unit of MM12-SF from the front of escalator to the direction of concourse near the ticket-
selling counter
Place 2 units of Moisture Mist Unit look from behind
2)Measurement position
We have tested the temperature and humidity in the middle of concourse near of the ticket-selling
counter.
About 15 meter from the Moisture Mist position.
Before use Temperature 30.3℃
Humidity 58.4%
5 minutes after useTemperature 27.0℃
Humidity 69.3%
(Before) 30.3℃ → (After use) 27.0℃ -3.3℃ (Temperature lowered)
Moisture Mist is able to raise the cooling effect which cooler or spot cooler cannot do.
8.Recommendation
We recommend you to use the cool breeze cooling of Moisture Mist.
Because of its natural coolness which, has humidity, it will not burden your body; just like a cooler
that is friendly to our body.
The use of multiple units can lower the surrounding temperature.
9.Moisture Mist Cost
Table1 MM12-SF MM6-SF
MM12-SF MM6-SF
8.Recommendation
We recommend you to use the cool breeze cooling of Moisture Mist.
Because of its natural coolness which, has humidity, it will not burden your body; just like a cooler
that is friendly to our body.
The use of multiple units can lower the surrounding temperature.
9.Moisture Mist Cost
Table1 MM12-SF MM6-SF